1.
N Engl J Med ; 388(25): 2360-2370, 2023 Jun 22.
Artículo en Inglés | MEDLINE | ID: mdl-37212442

RESUMEN

BACKGROUND: Single-chamber ventricular leadless pacemakers do not support atrial pacing or consistent atrioventricular synchrony. A dual-chamber leadless pacemaker system consisting of two devices implanted percutaneously, one in the right atrium and one in the right ventricle, would make leadless pacemaker therapy a treatment option for a wider range of indications. METHODS: We conducted a prospective, multicenter, single-group study to evaluate the safety and performance of a dual-chamber leadless pacemaker system. Patients with a conventional indication for dual-chamber pacing were eligible for participation. The primary safety end point was freedom from complications (i.e., device- or procedure-related serious adverse events) at 90 days. The first primary performance end point was a combination of adequate atrial capture threshold and sensing amplitude at 3 months. The second primary performance end point was at least 70% atrioventricular synchrony at 3 months while the patient was sitting. RESULTS: Among the 300 patients enrolled, 190 (63.3%) had sinus-node dysfunction and 100 (33.3%) had atrioventricular block as the primary pacing indication. The implantation procedure was successful (i.e., two functioning leadless pacemakers were implanted and had established implant-to-implant communication) in 295 patients (98.3%). A total of 35 device- or procedure-related serious adverse events occurred in 29 patients. The primary safety end point was met in 271 patients (90.3%; 95% confidence interval [CI], 87.0 to 93.7), which exceeded the performance goal of 78% (P<0.001). The first primary performance end point was met in 90.2% of the patients (95% CI, 86.8 to 93.6), which exceeded the performance goal of 82.5% (P<0.001). The mean (±SD) atrial capture threshold was 0.82±0.70 V, and the mean P-wave amplitude was 3.58±1.88 mV. Of the 21 patients (7%) with a P-wave amplitude of less than 1.0 mV, none required device revision for inadequate sensing. At least 70% atrioventricular synchrony was achieved in 97.3% of the patients (95% CI, 95.4 to 99.3), which exceeded the performance goal of 83% (P<0.001). CONCLUSIONS: The dual-chamber leadless pacemaker system met the primary safety end point and provided atrial pacing and reliable atrioventricular synchrony for 3 months after implantation. (Funded by Abbott Medical; Aveir DR i2i ClinicalTrials.gov number, NCT05252702.).


Asunto(s)
Arritmias Cardíacas , Estimulación Cardíaca Artificial , Marcapaso Artificial , Humanos , Fibrilación Atrial/terapia , Fibrilación Atrial/etiología , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/métodos , Estudios de Seguimiento , Marcapaso Artificial/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Arritmias Cardíacas/terapia
2.
Cardiovasc Diabetol ; 23(1): 224, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38943159

RESUMEN

BACKGROUND: Sodium-glucose cotransporter 2 (SGLT2) inhibitors reduce the risk of hospitalization for heart failure and cardiovascular death with type 2 diabetes; however, their effect on arrhythmias is unclear. The purpose of this study was to investigate the effects of empagliflozin on ventricular arrhythmias in patients with type 2 diabetes. METHODS: A total of 150 patients with type 2 diabetes who were treated with an implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator (ICD/CRT-D) were randomized to once-daily empagliflozin or placebo for 24 weeks. The primary endpoint was the change in the number of ventricular arrhythmias from the 24 weeks before to the 24 weeks during treatment. Secondary endpoints included the change in the number of appropriate device discharges and other values. RESULTS: In the empagliflozin group, the number of ventricular arrhythmias recorded by ICD/CRT-D decreased by 1.69 during treatment compared to before treatment, while in the placebo group, the number increased by 1.79. The coefficient for the between-group difference was - 1.07 (95% confidence interval [CI] - 1.29 to - 0.86; P < 0.001). The change in the number of appropriate device discharges during and before treatment was 0.06 in the empagliflozin group and 0.27 in the placebo group, with no significant difference between the groups (P = 0.204). Empagliflozin was associated with an increase in blood ketones and hematocrit and a decrease in blood brain natriuretic peptide and body weight. CONCLUSIONS: In patients with type 2 diabetes treated with ICD/CRT-D, empagliflozin reduces the number of ventricular arrhythmias compared with placebo. Trial registration jRCTs031180120.


Asunto(s)
Compuestos de Bencidrilo , Desfibriladores Implantables , Diabetes Mellitus Tipo 2 , Cardioversión Eléctrica , Glucósidos , Inhibidores del Cotransportador de Sodio-Glucosa 2 , Humanos , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/sangre , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Glucósidos/uso terapéutico , Glucósidos/efectos adversos , Compuestos de Bencidrilo/uso terapéutico , Compuestos de Bencidrilo/efectos adversos , Masculino , Inhibidores del Cotransportador de Sodio-Glucosa 2/uso terapéutico , Inhibidores del Cotransportador de Sodio-Glucosa 2/efectos adversos , Femenino , Anciano , Persona de Mediana Edad , Resultado del Tratamiento , Factores de Tiempo , Cardioversión Eléctrica/instrumentación , Cardioversión Eléctrica/efectos adversos , Método Doble Ciego , Japón , Terapia de Resincronización Cardíaca/efectos adversos , Glucemia/metabolismo , Glucemia/efectos de los fármacos
3.
Pacing Clin Electrophysiol ; 47(1): 127-130, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-38055652

RESUMEN

BACKGROUND: Using third-party resources to manage remote monitoring (RM) data from implantable cardiac electronic devices (CIEDs) can assist in device clinic workflows. However, each hospital-acquired data is not used for further analysis as big data. METHODS AND RESULTS: We developed a real-time and automatically centralized system of CIED information from multiple hospitals. If the extensive data-based analysis suggests individual problems, it can be returned to each hospital. To show its feasibility, we prospectively analyzed data from six hospitals. For example, unexpected abnormal battery levels were easily illustrated without recall information. CONCLUSIONS: The centralized RM system could be a new platform that promotes the utilization of device data as big data, and that information could be used for each patient's practice.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Humanos , Tecnología de Sensores Remotos/métodos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Monitoreo Fisiológico/métodos
4.
Circ J ; 87(8): 1058-1067, 2023 07 25.
Artículo en Inglés | MEDLINE | ID: mdl-37344406

RESUMEN

BACKGROUND: The association between the T-peak to T-end interval (Tp-e) and ventricular arrhythmia (VA) events in cardiac sarcoidosis (CS) is unknown. The purpose of this study was to investigate whether Tp-e was associated with VA events in CS patients with implantable cardioverter defibrillators (ICDs) or cardiac resynchronization therapy defibrillators (CRT-Ds).Methods and Results: We retrospectively studied 50 patients (16 men; mean [±SD] age 56.3±10.5 years) with CS and ICD/CRT-D. The maximum Tp-e in the precordial leads recorded by a 12-lead electrocardiogram after ICD/CRT-D implantation was evaluated. The clinical endpoint was defined as appropriate ICD therapy. During a median follow-up period of 85.0 months, 22 patients underwent appropriate therapy and 10 patients died. Kaplan-Meier analysis revealed that the probability of the clinical endpoint was 28.3% at 2 years and 35.3% at 4 years. The optimal cut-off value of the Tp-e for the prediction of the clinical endpoint was 91 ms, with a sensitivity of 72.7% and a specificity of 87.0% (area under the curve=0.81). Multivariate Cox regression analysis showed that Tp-e ≥91 ms (hazard ratio [HR] 5.10; 95% confidence interval [CI] 1.99-13.1; P<0.001) and a histological diagnosis of CS (HR 3.84; 95% CI 1.28-11.5; P=0.016) were significantly associated with the clinical endpoint. CONCLUSIONS: Tp-e ≥91 ms was a significant predictor of VA events in patients with CS and ICD/CRT-D.


Asunto(s)
Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Insuficiencia Cardíaca , Sarcoidosis , Masculino , Humanos , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Arritmias Cardíacas/terapia , Terapia de Resincronización Cardíaca/efectos adversos , Sarcoidosis/terapia , Resultado del Tratamiento , Insuficiencia Cardíaca/terapia
5.
Circ J ; 87(12): 1809-1816, 2023 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-37532552

RESUMEN

BACKGROUND: The Micra leadless pacemaker has demonstrated favorable outcomes in global trials, but its real-world performance and safety in a Japan-specific population is unknown.Methods and Results: Micra Acute Performance (MAP) Japan enrolled 300 patients undergoing Micra VR leadless pacemaker implantation in 15 centers. The primary endpoint was the acute (30-day) major complication rate. The 30-day and 6-month major complication rates were compared to global Micra studies. All patients underwent successful implantation with an average follow-up of 7.23±2.83 months. Compared with previous Micra studies, Japanese patients were older, smaller, more frequently female, and had a higher pericardial effusion risk score. 11 acute major complications were reported in 10 patients for an acute complication rate of 3.33% (95% confidence interval: 1.61-6.04%), which was in line with global Micra trials. Pericardial effusion occurred in 4 patients (1.33%; 3 major, 1 minor). No procedure or device-related deaths occurred. Frailty significantly improved from baseline to follow-up as assessed by Japan Cardiovascular Health Study criteria. CONCLUSIONS: In a Japanese cohort, implantation of the Micra leadless pacemaker had a high success rate and low major complication rate. Despite the Japan cohort being older, smaller, and at higher risk, the safety and performance was in line with global Micra trials.


Asunto(s)
Arritmias Cardíacas , Marcapaso Artificial , Femenino , Humanos , Pueblos del Este de Asia , Diseño de Equipo , Marcapaso Artificial/efectos adversos , Derrame Pericárdico/etiología , Resultado del Tratamiento , Masculino , Arritmias Cardíacas/terapia
6.
Pacing Clin Electrophysiol ; 46(3): 264-267, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36161665

RESUMEN

A 63-year-old man was admitted to the hospital due to ventricular tachycardia (VT) undersensing, caused by decreased R-wave amplitude in a cardiac resynchronization therapy defibrillator. The R-wave amplitude of VT sensed by the left ventricular (LV) lead was markedly higher than that by the right ventricular (RV) lead; therefore, we reconnected the IS-1 RV lead to the LV IS-1 port and the IS-1 LV lead to the RV IS-1 port to resolve this issue. After discharge, it was confirmed that VT was successfully terminated by the second sequence of intrinsic ATP (iATP, Medtronic, Minneapolis, MN, USA) from the LV lead.


Asunto(s)
Terapia de Resincronización Cardíaca , Taquicardia Ventricular , Masculino , Humanos , Persona de Mediana Edad , Resultado del Tratamiento , Taquicardia Ventricular/terapia , Arritmias Cardíacas , Desfibriladores
7.
Pacing Clin Electrophysiol ; 46(1): 59-65, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36417700

RESUMEN

BACKGROUND: Appropriate implantable cardioverter-defibrillator (ICD) shocks are associated with an increased risk of mortality and heart failure (HF) events. The first appropriate shock may occur late after implantation. However, whether the timing of the first appropriate shock influences prognosis is unknown. This study aimed to evaluate the clinical significance of the timing of the first appropriate shock in patients with ICD. METHODS: This retrospective and observational study enrolled 565 consecutive ICD patients. Patients who received an appropriate shock were divided into the early group (first appropriate shock <1 year after ICD implantation) and late group (first appropriate shock ≥1 year after ICD implantation). All-cause mortality was compared between the two groups. RESULTS: Over a median follow-up of 5.6 years, 112 (19.8%) patients received an appropriate shock, including 32 patients (28.6%) in the early group and 80 patients (71.4%) in the late group. Comparisons of baseline characteristics at ICD implantation revealed that the late group was more likely to receive cardiac resynchronization therapy (66.3% vs. 31.3%, p < 0.001), ICD for primary prevention (60.0% vs. 31.3%, p = 0.001), and angiotensin-converting enzyme inhibitor or angiotensin-receptor blocker treatment (88.8% vs. 71.9%, p = 0.028). Survival after shock was significantly worse in the late group than in the early group (p = 0.027). In multivariable Cox proportional hazards analysis, the late group had an increased risk of all-cause mortality compared with the early group (HR: 2.22; 95% CI 1.01-4.53; p = 0.029). In both groups, the most common cause of death was HF. CONCLUSIONS: Late occurrence of the first appropriate ICD shock was associated with a worse prognosis compared with early occurrence of the first appropriate shock. Cardiac death was the most common cause of death in patients who experienced late occurrence of the first appropriate ICD shock, resulting from HF in most cases.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca , Humanos , Desfibriladores Implantables/efectos adversos , Estudios Retrospectivos , Estudios de Seguimiento , Pronóstico , Muerte Súbita Cardíaca/etiología , Factores de Riesgo
8.
Heart Vessels ; 38(1): 77-89, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35879440

RESUMEN

Atrial fibrillation (AF) ablation can improve left ventricular ejection fraction (LVEF) and renal function and can even reduce mortality in patients with impaired LVEF. However, the effect of post-ablation cardiorenal dysfunction on the prognosis of patients with impaired LVEF who underwent AF ablation remains unclear. Of the 1243 consecutive patients undergoing AF ablation, the prognosis of 163 non-dialysis patients who underwent AF ablation with < 50% LVEF was evaluated. The primary outcome was a composite of all-cause mortality, heart failure hospitalization, and a need for modification of the treatment for heart failure. During the median follow-up of 4.2 years after the first AF ablation procedure, the primary outcome occurred in 30 of 163 patients (18%). The receiver operating characteristic curve analysis demonstrated that the post-LVEF (LVEF within 1 year after the procedure, and before the occurrence of primary outcome) had larger areas under the curve (0.70) than the pre-LVEF (LVEF before the procedure), and the most optimal cutoff value was LVEF ≤ 42%. Multivariate analysis demonstrated that patients with post-LVEF ≤ 42% and worsening renal function (WRF; an absolute increase in serum creatinine [SCr] ≥ 0.3 mg/dL compared with the SCr at baseline within 1 year after the procedure and before the occurrence of primary outcome) had a 3.4- to 4.3-fold and 3.4- to 3.7-fold higher risk of the primary outcome compared with those without these predictors, respectively. Patients were categorized using post-LVEF ≤ 42% and WRF as follows: group 1 (post-LVEF > 42% without WRF), group 2 (post-LVEF ≤ 42% without WRF), group 3 (post-LVEF > 42% with WRF), and group 4 (post-LVEF ≤ 42% with WRF). Group 4 had a 15.8-fold (P = 0.0001) higher risk of the primary outcome compared with group 1 after adjusting for pre-procedural factors. In patients with impaired LVEF undergoing AF ablation, post-LVEF ≤ 42% and WRF were independent predictors of poor prognosis. The combination of post-LVEF ≤ 42% and WRF is strongly associated with a poor prognosis in patients with AF undergoing ablation, who with these post-ablation cardiorenal dysfunction may have to be treated more intensively after AF ablation.


Asunto(s)
Fibrilación Atrial , Cardiomiopatías , Ablación por Catéter , Insuficiencia Cardíaca , Disfunción Ventricular Izquierda , Humanos , Fibrilación Atrial/complicaciones , Fibrilación Atrial/cirugía , Pronóstico , Función Ventricular Izquierda , Volumen Sistólico , Resultado del Tratamiento , Disfunción Ventricular Izquierda/complicaciones , Cardiomiopatías/complicaciones , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
9.
BMC Cardiovasc Disord ; 22(1): 374, 2022 08 16.
Artículo en Inglés | MEDLINE | ID: mdl-35974317

RESUMEN

BACKGROUND: Appropriate shock therapy is associated with subsequent all-cause death in heart failure (HF) patients who receive an implantable cardioverter defibrillator (ICD) for the primary prevention of sudden cardiac death. To evaluate the impact of signal-averaged electrocardiography (SAECG) findings on appropriate shocks in prophylactic ICD patients with nonischemic systolic HF. METHODS: We studied 86 patients with nonischemic HF and a left ventricular ejection fraction ≤ 35% who underwent new ICD implantation for the primary prevention of sudden cardiac death. We excluded patients who had a previously implanted permanent pacemaker and patients who received cardiac resynchronization therapy with an ICD. SAECG was performed before implantation. Abnormal SAECG findings were defined if 2 of the following 3 conditions were identified: filtered QRS duration (fQRS) ≥ 114 ms, root-mean-square voltage during the last 40 ms of the fQRS (RMS 40) < 20 µV, and duration of the low-amplitude potentials < 40 µV (LAS 40) > 38 ms; additionally, patients with a QRS complex ≥ 120 ms who met both the RMS 40 and LAS 40 criteria were also considered to have abnormal SAECG findings. The primary outcome was the first occurrence of appropriate shock after implantation of the ICD. The secondary outcomes were the first occurrence of inappropriate shock and all-cause mortality. RESULTS: Forty-two patients met the criteria for abnormal SAECG findings (49%). During a median follow-up period of 61 months, 17 patients (20%) died, 24 (28%) received appropriate shock therapy, and 19 (22%) received inappropriate shock therapy. There was a significantly higher incidence of appropriate shocks in patients with abnormal SAECG findings than in those with normal SAECG findings (log-rank test, p = 0.025). Multivariate analysis revealed that abnormal SAECG findings were independently associated with the occurrence of appropriate shock (hazard ratio 2.67, 95% confidential interval 1.14-6.26). However, abnormal SAECG findings were not related to inappropriate shock. There was no difference in the incidence of all-cause death between patients with abnormal and normal SAECG findings. CONCLUSIONS: Our results suggest that abnormal SAECG findings are associated with a high probability of appropriate shocks in prophylactic ICD patients with nonischemic systolic HF.


Asunto(s)
Desfibriladores Implantables , Insuficiencia Cardíaca Sistólica , Insuficiencia Cardíaca , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables/efectos adversos , Electrocardiografía/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/etiología , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca Sistólica/diagnóstico , Insuficiencia Cardíaca Sistólica/terapia , Humanos , Factores de Riesgo , Volumen Sistólico , Función Ventricular Izquierda
10.
J Cardiovasc Electrophysiol ; 32(2): 279-286, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33382508

RESUMEN

INTRODUCTION: Given that few studies investigated the efficacy of catheter ablation (CA) in patients with paroxysmal atrial fibrillation (AF) and atrial septal defect (ASD), this study evaluated its effectiveness in patients with paroxysmal AF and ASD. METHODS AND RESULTS: Of the 216 patients who underwent ASD device closure at two hospitals, 36 patients had paroxysmal AF. After April 2012, CA for AF was performed before ASD device closure (ASD-CA group; n = 20). The ASD-CA group had a significantly higher AF-free survival rate after ASD device closure compared to patients without CA for AF before ASD device closure (ASD-non-CA group; n = 16) (ASD-CA group: 2 patients vs. ASD-non-CA group: 9 patients; follow-up period: 4.2 ± 2.5 years; log-rank p = .01). In addition, the AF-free survival rates were similar between the ASD-CA group and 80 paroxysmal AF patients who underwent CA without any detectable structural heart disease (non-SHD-CA group). The two groups were matched by propensity scores for age, sex, and left atrium dimension (ASD-CA group: 2 patients vs. non-SHD-CA group: 5 patients; follow-up period: 3.3 ± 1.8 years; log-rank p = .28). CONCLUSION: CA for AF before ASD device closure might be an effective treatment option for patients with paroxysmal AF and ASD.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Defectos del Tabique Interatrial , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Defectos del Tabique Interatrial/complicaciones , Defectos del Tabique Interatrial/diagnóstico , Defectos del Tabique Interatrial/cirugía , Humanos , Resultado del Tratamiento
11.
Circ J ; 85(8): 1349-1355, 2021 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-33814523

RESUMEN

BACKGROUND: The number of patients undergoing cardiac resynchronization therapy has increased. Consequently, there is increased frequency in the removal and reimplantation of coronary venous (CV) leads due to infection or malfunction.Methods and Results:A total of 345 consecutive patients referred for lead(s) extraction were reviewed. Of these, 34 patients who underwent a CV lead removal were investigated. The indications for CV leads removal were device-related infections in 29 patients and lead malfunctions in 5 patients. The average duration of the CV leads was 4.1±3.8 years. All CV leads were successfully removed without any major complications, except for 1 in-hospital death. Successful CV lead removal by simple traction (ST) was achieved in 21 patients (62%), whereas extraction tools were required in 13 patients (38%). Local infection and CV lead dwell time were significantly associated with successful ST (P=0.04 and P=0.014, respectively). CV lead re-implantation was successfully performed in 25 patients; however, a right-side approach was required in 92%, and occlusion/stenosis of the previous CV was observed in 80% of the patients. CONCLUSIONS: CV lead removal is relatively successful and safe. The presence of local infection and a shorter lead duration may enable successful ST of a CV lead. However, the re-implantation procedure should be well prepared for the complexity related to the right-side approach and occlusion/stenosis of the previous CV.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Constricción Patológica , Remoción de Dispositivos , Electrodos Implantados , Mortalidad Hospitalaria , Humanos , Reimplantación , Resultado del Tratamiento
12.
BMC Cardiovasc Disord ; 21(1): 106, 2021 02 19.
Artículo en Inglés | MEDLINE | ID: mdl-33607967

RESUMEN

BACKGROUND: Conventional risk factors for sudden cardiac death (SCD) justify primary prevention through implantable cardioverter-defibrillator (ICD) implantation in hypertrophic cardiomyopathy (HCM) patients. However, the positive predictive values for these conventional SCD risk factors are low. Left ventricular outflow tract obstruction (LVOTO) and midventricular obstruction (MVO) are potential risk modifiers for SCD. The aims of this study were to evaluate whether an elevated intraventricular pressure gradient (IVPG), including LVOTO or MVO, is a potential risk modifier for SCD and ventricular arrhythmias requiring ICD interventions in addition to the conventional risk factors among HCM patients receiving ICDs for primary prevention. METHODS: We retrospectively studied 60 HCM patients who received ICDs for primary prevention. An elevated IVPG was defined as a peak instantaneous gradient ≥ 30 mmHg at rest, as detected by continuous-wave Doppler echocardiography. The main outcome was a composite of SCD and appropriate ICD interventions, which were defined as an antitachycardia pacing or shock therapy for ventricular tachycardia or fibrillation. The Cox proportional hazards model was used to assess the relationships between risk factors and the occurrence of SCD and appropriate ICD interventions. RESULTS: Thirty patients met the criteria of elevated IVPG (50%). During the median follow-up period of 66 months, 2 patients experienced SCD, and 10 patients received appropriate ICD interventions. Kaplan-Meier curves showed that the incidence of the main outcome was higher in patients with an IVPG ≥ 30 mmHg than in those without an IVPG ≥ 30 mmHg (log-rank P = 0.03). There were no differences in the main outcome between patients with LVOTO and patients with MVO. The combination of nonsustained ventricular tachycardia (NSVT) and IVPG ≥ 30 mmHg was found to significantly increase the risk of the main outcome (HR 6.31, 95% CI 1.36-29.25, P = 0.02). Five patients experienced ICD implant-related complications. CONCLUSIONS: Our findings showed that a baseline IVPG ≥ 30 mmHg was associated with an increased risk of experiencing SCD or appropriate ICD interventions among HCM patients who received ICDs for primary prevention. Combined with NSVT, which is a conventional risk factor, a baseline IVPG ≥ 30 mmHg may be a potential modifier of SCD risk in HCM patients.


Asunto(s)
Cardiomiopatía Hipertrófica/terapia , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Prevención Primaria/instrumentación , Taquicardia Ventricular/prevención & control , Fibrilación Ventricular/prevención & control , Función Ventricular Izquierda , Presión Ventricular , Adulto , Anciano , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/mortalidad , Cardiomiopatía Hipertrófica/fisiopatología , Ecocardiografía Doppler , Cardioversión Eléctrica/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidad , Taquicardia Ventricular/fisiopatología , Resultado del Tratamiento , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/mortalidad , Fibrilación Ventricular/fisiopatología
13.
Pacing Clin Electrophysiol ; 44(7): 1287-1291, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33728644

RESUMEN

A 36-years-old woman with a congenital corrected transposition of the great arteries, who underwent Senning and Rastelli operations, was admitted with a symptomatic supraventricular tachycardia. During an electrophysiological study, uncommon atrioventricular (AV) nodal reentrant tachycardia was induced. The coronary veins and coronary sinus did not connect to the systemic venous atrium. The His bundle electrogram (HBE) was recorded at the anterior septum of the mitral valve via the aorta. The target of ablation was the site of the earliest atrial activation during the tachycardia, 5 mm posterior to the AV node, and a successful cryoablation was performed using a transaortic approach. Both the antegrade and retrograde conduction of the slow AV nodal pathway was eliminated.


Asunto(s)
Criocirugía/métodos , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Adulto , Aorta , Procedimientos Quirúrgicos Cardíacos/métodos , Femenino , Humanos
14.
Pacing Clin Electrophysiol ; 44(1): 181-184, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33210728

RESUMEN

A 42-year-old woman with tricuspid atresia who underwent a Fontan surgery (atrio-pulmonary connection) was admitted to our hospital due to symptomatic ventricular tachycardia (VT). A defibrillation lead was implanted in a distal site of a coronary vein since there was no usual entry to the ventricle. Ventricular pacing was impossible due to the high threshold, however, good sensing was obtained. Three years later, she felt palpitations and a subsequent shock therapy while climbing stairs. The cardioverter data showed that an appropriate cardioversion therapy successfully converted VT to normal rhythm.


Asunto(s)
Desfibriladores Implantables , Procedimiento de Fontan , Complicaciones Posoperatorias/terapia , Taquicardia Ventricular/terapia , Adulto , Femenino , Humanos , Complicaciones Posoperatorias/fisiopatología , Taquicardia Ventricular/fisiopatología
15.
Heart Vessels ; 36(6): 882-889, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33394103

RESUMEN

Transvenous lead extraction (TLE) for cardiac implantable electric device (CIED) infection is becoming increasingly common, but is believed to be particularly risky in elderly patients. This study aimed to clarify the safety and effectiveness of TLE in the elderly, evaluating the use of both non-laser and laser extraction tools. We retrospectively analyzed the characteristics, device type, indications, procedures, and clinical results in younger (YG; age: 15-79 years; n = 48) and elderly groups (EG; age: ≥ 80 years; n = 27) of patients who underwent percutaneous TLE between April 2014 and December 2019 at our hospital. The average age was 68 and 88 years in the YG and EG, respectively. Indications for TLE were infection in 33 (68.8%) patients and other in 15 (30.6%) patients in the YG, and infection in all 27 (100%) EG patients. Bloodstream infection was detected in 9 and 4 patients in the YG and EG, respectively, with methicillin-resistant Staphylococcus epidermidis being the most common causative pathogen. All TLE procedures were performed under general anesthesia in an operating room with cardiovascular surgeon backup. An excimer laser sheath (76 leads), a laser followed by a mechanical sheath (45 leads), Evolution RL® (17 leads), a mechanical sheath (9 leads), and manual traction (one lead) were employed to extract a total of 148 leads (98 and 50 in the YG and EG, respectively). A mechanical sheath or Evolution RL® was more frequently used in the YG. The respective average implantation durations in the YG and EG were 5.3 and 5.0 years, respectively, which were comparable (p = 0.46). Procedural success rates were identical between the YG and EG (99% vs. 100%, respectively). There was only one procedure-related complication in the entire cohort (cardiac tamponade in a YG patient). Taken together, the success rates of TLE were high in the EG, with no complications, with extraction being the indication for infection in all EG patients. Percutaneous TLE was safe and effective in elderly patients using both non-laser and laser techniques.


Asunto(s)
Cateterismo Cardíaco/métodos , Desfibriladores Implantables , Remoción de Dispositivos/métodos , Terapia por Láser/estadística & datos numéricos , Láseres de Excímeros/estadística & datos numéricos , Marcapaso Artificial , Adolescente , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Japón , Terapia por Láser/métodos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
16.
J Electrocardiol ; 65: 73-75, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33556738

RESUMEN

A 75-year-old woman, who had never exhibited a delta wave before, was diagnosed with sigmoid colon cancer and underwent surgical operation. Takotsubo cardiomyopathy (TC) occurred shortly after the operation. About 2 weeks following the onset of TC, a 12­lead electrocardiogram revealed a delta wave that was present for 50 days, and the patient was diagnosed with transient ventricular pre-excitation. The delta wave disappeared prior to patient's discharge and was never observed thereafter. This transient appearance of a delta wave may be related to a pathological modulation of the autonomic nervous system during the acute phase of TC.


Asunto(s)
Síndromes de Preexcitación , Cardiomiopatía de Takotsubo , Anciano , Electrocardiografía , Femenino , Humanos , Cardiomiopatía de Takotsubo/diagnóstico
17.
Cardiol Young ; 31(8): 1356-1358, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33632346

RESUMEN

Familial atrial fibrillation is inherited and sporadically occurs in the paediatric population. Generally, fibrillated wavelets are reported at a frequency of approximately 6 Hz. Herein, we report a familial case presenting rapidly fibrillated wavelets at frequencies of approximately 12 to 30 Hz associated with KCNQ1 and SCN5A mutations.


Asunto(s)
Fibrilación Atrial , Canal de Potasio KCNQ1 , Fibrilación Atrial/genética , Niño , Humanos , Canal de Potasio KCNQ1/genética , Mutación , Canal de Sodio Activado por Voltaje NAV1.5/genética
18.
Cardiol Young ; 31(2): 315-317, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33172511

RESUMEN

We report a case with Ebstein's anomaly and pulmonary atresia with sustained monomorphic ventricular tachycardia in a patient without a ventriculotomy history. In the low voltage area between the atrialised right ventricle and hypoplastic right ventricle, there was a ventricular tachycardia substrate and slow conduction. The tachycardia circuit was eliminated by a point catheter ablation at the area with diastolic fractionated potentials.


Asunto(s)
Ablación por Catéter , Anomalía de Ebstein , Cardiopatías Congénitas , Atresia Pulmonar , Taquicardia Ventricular , Anomalía de Ebstein/complicaciones , Anomalía de Ebstein/diagnóstico , Anomalía de Ebstein/cirugía , Humanos , Atresia Pulmonar/complicaciones , Atresia Pulmonar/cirugía , Taquicardia Ventricular/etiología , Taquicardia Ventricular/cirugía
19.
J Cardiovasc Electrophysiol ; 31(1): 89-99, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31724792

RESUMEN

INTRODUCTION: Although a high prevalence of the presence of an accessory pathway (AP) associated with atrioventricular (AV) discordance has been reported, a case series of its characteristics and the results of catheter ablation (CA) have not been sufficiently documented. METHODS AND RESULTS: We retrospectively examined 11 consecutive patients with atrioventricular discordance who underwent CA for atrioventricular reciprocating tachycardia (AVRT) via an AP and planned cardiac surgery after CA. Orthodromic AVRTs were induced in 10 patients via AP, but no antidromic/duodromic AVRT was induced in any of the cases. A total of 13 APs were identified, and all of them were located around the anatomical tricuspid valve (TV) annulus, including two Ebsteinoid valves. The APs were predominantly located posteriorly, posterolaterally, and posteroseptally on the TV in nine patients (82%). Two patients (18%) had multiple APs or a single broad AP. Four (36%) and three (27%) patients showed twin AVNs and other supraventricular tachycardias (SVTs) except AVRT via the AP. Ten patients (91%) had acute successful CA in the first session, except for one patient with multiple APs who required the third session to eliminate all APs before the planned Fontan surgery. There were no major complications associated with CA. Seven of eight patients who underwent cardiac surgery after CA did not experience peri-/postoperative SVT. CONCLUSION: APs in patients with AV discordance are usually associated with the anatomical TV annulus. CA of an AP in AV discordance is highly effective and recommended to reduce the risk of SVT. The coexistence of twin AVNs and other SVTs should be considered during CA of an AP in AV discordance.


Asunto(s)
Fascículo Atrioventricular Accesorio/cirugía , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Frecuencia Cardíaca , Taquicardia Reciprocante/cirugía , Taquicardia Supraventricular/cirugía , Fascículo Atrioventricular Accesorio/diagnóstico , Fascículo Atrioventricular Accesorio/fisiopatología , Potenciales de Acción , Adulto , Ablación por Catéter/efectos adversos , Niño , Preescolar , Femenino , Humanos , Lactante , Masculino , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Taquicardia Reciprocante/diagnóstico , Taquicardia Reciprocante/fisiopatología , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento
20.
J Cardiovasc Electrophysiol ; 31(12): 3132-3140, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33079461

RESUMEN

INTRODUCTION: Some patients with cardiac implantable electronic devices (CIEDs) require atrial fibrillation (AF) ablation, and the superior vena cava (SVC) has been identified as one of the most common non-pulmonary vein foci of AF. This study aimed to investigate the interaction between SVC isolation (SVCI) and CIED leads implanted through the SVC. METHODS AND RESULTS: We studied 34 patients with CIEDs who had undergone SVCI as part of AF ablation (CIED group), involving a total of 71 CIED leads. A similar number of age-, sex-, and AF type-matched patients without CIEDs formed a control group (non-CIED group). Patients' background and procedural characteristics were compared between the groups. In the CIED group, lead parameters before and after AF ablation were compared, and lead failure after AF ablation was also examined in detail. Procedural characteristics other than fluoroscopic time were similar in both groups. The success rate of SVCI after the final ablation procedure was 91.2% in the CIED group and 100% in the non-CIED group; however, these differences were not statistically significant. Lead parameters before and after the AF ablation did not significantly differ between the two groups. Lead failure was observed in three patients, with a sensing noise in one patient and an impedance increase in two patients after SVCI. CONCLUSION: SVCI was achievable without lead failure and significant change in lead parameters in most patients with CIEDs; however, it should be noted that lead failure was observed in 8.8% of the study patients after SVCI.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Electrónica , Estudios de Factibilidad , Humanos , Venas Pulmonares/cirugía , Resultado del Tratamiento , Vena Cava Superior/diagnóstico por imagen , Vena Cava Superior/cirugía
SELECCIÓN DE REFERENCIAS