Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 686
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Nature ; 589(7841): 214-219, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33408416

RESUMEN

Quantum key distribution (QKD)1,2 has the potential to enable secure communication and information transfer3. In the laboratory, the feasibility of point-to-point QKD is evident from the early proof-of-concept demonstration in the laboratory over 32 centimetres4; this distance was later extended to the 100-kilometre scale5,6 with decoy-state QKD and more recently to the 500-kilometre scale7-10 with measurement-device-independent QKD. Several small-scale QKD networks have also been tested outside the laboratory11-14. However, a global QKD network requires a practically (not just theoretically) secure and reliable QKD network that can be used by a large number of users distributed over a wide area15. Quantum repeaters16,17 could in principle provide a viable option for such a global network, but they cannot be deployed using current technology18. Here we demonstrate an integrated space-to-ground quantum communication network that combines a large-scale fibre network of more than 700 fibre QKD links and two high-speed satellite-to-ground free-space QKD links. Using a trusted relay structure, the fibre network on the ground covers more than 2,000 kilometres, provides practical security against the imperfections of realistic devices, and maintains long-term reliability and stability. The satellite-to-ground QKD achieves an average secret-key rate of 47.8 kilobits per second for a typical satellite pass-more than 40 times higher than achieved previously. Moreover, its channel loss is comparable to that between a geostationary satellite and the ground, making the construction of more versatile and ultralong quantum links via geosynchronous satellites feasible. Finally, by integrating the fibre and free-space QKD links, the QKD network is extended to a remote node more than 2,600 kilometres away, enabling any user in the network to communicate with any other, up to a total distance of 4,600 kilometres.

2.
Nature ; 582(7813): 501-505, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32541968

RESUMEN

Quantum key distribution (QKD)1-3 is a theoretically secure way of sharing secret keys between remote users. It has been demonstrated in a laboratory over a coiled optical fibre up to 404 kilometres long4-7. In the field, point-to-point QKD has been achieved from a satellite to a ground station up to 1,200 kilometres away8-10. However, real-world QKD-based cryptography targets physically separated users on the Earth, for which the maximum distance has been about 100 kilometres11,12. The use of trusted relays can extend these distances from across a typical metropolitan area13-16 to intercity17 and even intercontinental distances18. However, relays pose security risks, which can be avoided by using entanglement-based QKD, which has inherent source-independent security19,20. Long-distance entanglement distribution can be realized using quantum repeaters21, but the related technology is still immature for practical implementations22. The obvious alternative for extending the range of quantum communication without compromising its security is satellite-based QKD, but so far satellite-based entanglement distribution has not been efficient23 enough to support QKD. Here we demonstrate entanglement-based QKD between two ground stations separated by 1,120 kilometres at a finite secret-key rate of 0.12 bits per second, without the need for trusted relays. Entangled photon pairs were distributed via two bidirectional downlinks from the Micius satellite to two ground observatories in Delingha and Nanshan in China. The development of a high-efficiency telescope and follow-up optics crucially improved the link efficiency. The generated keys are secure for realistic devices, because our ground receivers were carefully designed to guarantee fair sampling and immunity to all known side channels24,25. Our method not only increases the secure distance on the ground tenfold but also increases the practical security of QKD to an unprecedented level.

3.
Nature ; 569(7756): 378-382, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-31092939

RESUMEN

Over 60 years of spacecraft exploration has revealed that the Earth's Moon is characterized by a lunar crust1 dominated by the mineral plagioclase, overlying a more mafic (richer in iron and magnesium) mantle of uncertain composition. Both crust and mantle formed during the earliest stages of lunar evolution when late-stage accretional energy caused a molten rock (magma) ocean, flotation of the light plagioclase, sinking of the denser iron-rich minerals, such as olivine and pyroxene, and eventually solidification2. Very large impact craters can potentially penetrate through the crust and sample the lunar mantle. The largest of these craters is the approximately 2,500-kilometre-diameter South Pole-Aitken (SPA) basin3 on the lunar far side. Evidence obtained from orbiting spacecraft shows that the floor of the SPA basin is rich in mafic minerals4, but their mantle origin is controversial and their in situ geologic settings are poorly known. China's Chang'E-4 lunar far-side lander recently touched down in the Von Kármán crater5,6 to explore the floor of the huge SPA basin and deployed its rover, Yutu-2. Here we report on the initial spectral observations of the Visible and Near Infrared Spectrometer (VNIS)7 onboard Yutu-2, which we interpret to represent the presence of low-calcium (ortho)pyroxene and olivine, materials that may originate from the lunar mantle. Geological context6 suggests that these materials were excavated from below the SPA floor by the nearby 72-km-diameter Finsen impact crater event, and transported to the landing site. Continued exploration by Yutu-2 will target these materials on the floor of the Von Kármán crater to understand their geologic context, origin and abundance, and to assess the possibility of sample-return scenarios.

4.
Radiology ; 311(1): e230459, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38563669

RESUMEN

Background Microwave ablation (MWA) is currently under preliminary investigation for the treatment of multifocal papillary thyroid carcinoma (PTC) and has shown promising treatment efficacy. Compared with surgical resection (SR), MWA is minimally invasive and could preserve thyroid function. However, a comparative analysis between MWA and SR is warranted to draw definitive conclusions. Purpose To compare MWA and SR for preoperative US-detected T1N0M0 multifocal PTC in terms of overall and 1-, 3-, and 5-year progression-free survival rates and complication rates. Materials and Methods In this retrospective study, 775 patients with preoperative US-detected T1N0M0 multifocal PTC treated with MWA or SR across 10 centers between May 2015 and December 2021 were included. Propensity score matching (PSM) was performed for patients in the MWA and SR groups, followed by comparisons between the two groups. The primary outcomes were overall and 1-, 3-, and 5-year progression-free survival (PFS) rates and complication rates. Results After PSM, 229 patients (median age, 44 years [IQR 36.5-50.5 years]; 179 female) in the MWA group and 453 patients (median age, 45 years [IQR 37-53 years]; 367 female) in the SR group were observed for a median of 20 months (range, 12-74 months) and 26 months (range, 12-64 months), respectively. MWA resulted in less blood loss, shorter incision length, and shorter procedure and hospitalization durations (all P < .001). There was no evidence of differences in overall and 1-, 3-, or 5-year PFS rates (all P > .05) between MWA and SR (5-year rate, 77.2% vs 83.1%; P = .36) groups. Permanent hoarseness (2.2%, P = .05) and hypoparathyroidism (4.0%, P = .005) were encountered only in the SR group. Conclusion There was no evidence of a significant difference in PFS rates between MWA and SR for US-detected multifocal T1N0M0 PTC, and MWA resulted in fewer complications. Therefore, MWA is a feasible option for selected patients with multifocal T1N0M0 PTC. © RSNA, 2024 Supplemental material is available for this article. See also the editorial by Georgiades in this issue.


Asunto(s)
Microondas , Neoplasias de la Tiroides , Humanos , Femenino , Adulto , Persona de Mediana Edad , Microondas/uso terapéutico , Estudios Retrospectivos , Cáncer Papilar Tiroideo/diagnóstico por imagen , Cáncer Papilar Tiroideo/cirugía , Hospitalización , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/cirugía
5.
Opt Express ; 32(5): 8101-8121, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38439476

RESUMEN

It is extremely challenging to rapidly and accurately extract target echo photon signals from massive photon point clouds with strong background noise without any prior geographic information. Herein, we propose a fast surface detection method realized by combining the improved density-dimension algorithm (DDA) and Kalman filtering (KF), termed the DDA-KF algorithm, for photon signals with a high background noise rate (BNR) to improve the extraction of surface photon signals from spacecraft platforms. The results showed that the algorithm exhibited good adaptability to strong background noise and terrain slope variations, and had real-time processing capabilities for massive photon point clouds in large-scale detection range without prior altitude information of target. Our research provides a practical technical solution for single-photon lidar applications in deep space navigation and can help improve the performance in environments characterized by strong background noise.

6.
Opt Express ; 32(5): 7426-7447, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38439423

RESUMEN

A near-infrared single-photon lidar system, equipped with a 64×64 resolution array and a Risley prism scanner, has been engineered for daytime long-range and high-resolution 3D imaging. The system's detector, leveraging Geiger-mode InGaAs/InP avalanche photodiode technology, attains a single-photon detection efficiency of over 15% at the lidar's 1064 nm wavelength. This efficiency, in tandem with a narrow pulsed laser that boasts a single-pulse energy of 0.5 mJ, facilitates 3D imaging capabilities for distances reaching approximately 6 kilometers. The Risley scanner, composing two counter-rotating wedge prisms, is designed to perform scanning measurements across a 6-degree circular field-of-view. Precision calibration of the scanning angle and the beam's absolute direction was achieved using a precision dual-axis turntable and a collimator, culminating in 3D imaging with an exceptional scanning resolution of 28 arcseconds. Additionally, this work has developed a novel spatial domain local statistical filtering framework, specifically designed to separate daytime background noise photons from the signal photons, enhancing the system's imaging efficacy in varied lighting conditions. This paper showcases the advantages of array-based single-photon lidar image-side scanning technology in simultaneously achieving high resolution, a wide field-of-view, and extended detection range.

7.
Langmuir ; 40(24): 12818-12827, 2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38842118

RESUMEN

The rebound dynamics of double droplets impacting an inclined superhydrophobic surface decorated with macro-ridges are investigated via lattice Boltzmann method (LBM) simulations. Four rebound regions are identified, that is, the no-coalescence-rebound (NCR), the partial-coalescence-rebound of the middle part bounces first (PCR-M), and the side part bounces first (PCR-S), as well as the complete-coalescence-rebound (CCR). The occurrence of the rebound regions strongly depends on the droplet arrangement, the center-to-center distance of the droplets, and the Weber number. Furthermore, the contact time is closely related to the rebound regions. The PCR-M region can significantly reduce the contact time because the energy dissipation in this region may decrease which can promote the rebound dynamic. Intriguingly, the contact time is also affected by the droplet arrangement; i.e., droplets arranged parallel to the ridge dramatically shorten the contact time since this arrangement increases the asymmetry of the liquid film. Therefore, for multidrop impact, the contact time can be effectively manipulated by changing the rebound region and the droplet arrangement. This work focuses on elucidating the wetting behaviors, rebound regions, and contact time of the multiple-droplet impacting an inclined superhydrophobic surface decorated with macro-ridges.

8.
Langmuir ; 40(20): 10759-10768, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38712734

RESUMEN

Bouncing dynamics of a trailing drop off-center impacting a leading drop with varying time intervals and Weber numbers are investigated experimentally. Whether the trailing drop impacts during the spreading or receding process of the leading drop is determined by the time interval. For a short time interval of 0.15 ≤ Δt* ≤ 0.66, the trailing drop impacts during the spreading of the leading drop, and the drops completely coalesce and rebound; for a large time interval of 0.66 < Δt* ≤ 2.21, the trailing drop impacts during the receding process, and the drops partially coalesce and rebound. Whether the trailing drop directly impacts the surface or the liquid film of the leading drop is determined by the Weber number. The trailing drop impacts the surface directly at moderate Weber numbers of 16.22 ≤ We ≤ 45.42, while it impacts the liquid film at large Weber numbers of 45.42 < We ≤ 64.88. Intriguingly, when the trailing drop impacts the surface directly or the receding liquid film, the contact time increases linearly with the time interval but independent of the Weber number; when the trailing drop impacts the spreading liquid film, the contact time suddenly increases, showing that the force of the liquid film of the leading drop inhibits the receding of the trailing drop. Finally, a theoretical model of the contact time for the drops is established, which is suitable for different impact scenarios of the successive off-center impact. This study provides a quantitative relationship to calculate the contact time of drops successively impacting a superhydrophobic surface, facilitating the design of anti-icing surfaces.

9.
Eur Radiol ; 34(1): 569-578, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37548692

RESUMEN

OBJECTIVE: Microwave ablation (MWA) has emerged as a minimally invasive technology for papillary thyroid microcarcinoma (PTMC), but it has not been widely applied to treat T1bN0M0 PTC with high-level evidence. This study was designed to compare the real-world efficacy and safety of MWA or surgery for treating T1bN0M0 PTC. METHODS: From December 2019 to April 2021, 123 continuous unifocal T1bN0M0 PTC patients without lymph node metastasis (LNM) or distant metastasis (DM) were included from 10 hospitals. Patients were allocated into the MWA or surgery group based on their willingness. The main outcomes were local tumour progression (LTP), new thyroid cancer, LNM, and DM. The secondary outcomes included changes in tumour size and volume, complications, and cosmetic results. Subgroup analyses were conducted to identify influencing factors. RESULTS: Fifty-two patients chose MWA, and 71 patients chose surgery. Patients had similar demographic information and tumour characteristics in the two groups. The follow-up durations after MWA and surgery were 10.6 ± 4.2 and 10.4 ± 3.4 months, respectively. The LNM rate was 5.8% in the MWA group and 1.4% in the surgery group (p = 0.177). No LTP, new thyroid cancer, or distant metastasis (DM) occurred in either group. Five (9.6%) of the 52 patients in the MWA group and 8 (11.3%) of the 71 patients in the surgery group had complications (p = 0.27). Better cosmetic results were found in the MWA group (p < 0.01). CONCLUSION: MWA achieved comparable short-term treatment efficacy with surgery. MWA might be an optional choice for surgery for low-risk T1bN0M0 PTC but concerns about LNM need to be studied further. CLINICAL RELEVANCE STATEMENT: MWA achieved comparable short-time treatment efficacy with surgery. MWA might be an optional choice for surgery for low-risk T1bN0M0 PTC. KEY POINTS: • MWA achieved comparable short-term treatment efficacy with surgery. MWA might be an optional choice for surgery for low-risk T1bN0M0 PTC but concerns about LNM need to be studied further. • The complication rate in the surgery group was higher than that in the MWA group without a significant difference. • There was no statistically significant difference in the LNM rate between the MWA and surgery groups.


Asunto(s)
Microondas , Neoplasias de la Tiroides , Humanos , Cáncer Papilar Tiroideo/cirugía , Cáncer Papilar Tiroideo/patología , Microondas/uso terapéutico , Estudios Prospectivos , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/cirugía , Neoplasias de la Tiroides/patología , Metástasis Linfática , Ultrasonografía Intervencional , Estudios Retrospectivos
10.
J Periodontal Res ; 59(3): 589-598, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38481308

RESUMEN

OBJECTIVES: In order to evaluate the effect of methacrylated hyaluronic acid (HAMA) hydrogels containing the recombinant human amelogenin (rhAm) in vitro and in vivo. BACKGROUND: The ultimate goal in treating periodontal disease is to control inflammation and achieve regeneration of periodontal tissues. In recent years, methacrylated hyaluronic acid (HAMA) containing recombinant human amyloid protein (rhAm) has been widely used as a new type of biomaterial in tissue engineering and regenerative medicine. However, there is a lack of comprehensive research on the periodontal regeneration effects of this hydrogel. This experiment aims to explore the application of photoresponsive recombinant human amelogenin-loaded hyaluronic acid hydrogel for periodontal tissue regeneration and provide valuable insights into its potential use in this field. MATERIALS AND METHODS: The effects of rhAm-HAMA hydrogel on the proliferation of human periodontal ligament cells (hPDLCs) were assessed using the CCK-8 kit. The osteogenic differentiation of hPDLCs was evaluated through ALP staining and real-time PCR. Calvarial parietal defects were created in 4-week-old Sprague Dawley rats and implanted with deproteinized bovine bone matrix in different treatment groups. The animals were euthanized after 4 and 8 weeks of healing. The bone volume of the defect was observed by micro-CT and histological analysis. RESULTS: Stimulating hPDLCs with rhAm-HAMA hydrogel did not significantly affect their proliferation (p > .05). ALP staining and real-time PCR results demonstrated that the rhAm-HAMA group exhibited a significant upregulation of osteoclastic gene expression (p < .05). Micro-CT results revealed a significant increase in mineralized tissue volume fraction (MTV/TV%), trabecular bone number (Tb.N), and mineralized tissue density (MTD) of the bone defect area in the rhAm-HAMA group compared to the other groups (p < .05). The results of hematoxylin and eosin staining and Masson staining at 8 weeks post-surgery further supported the results of the micro-CT. CONCLUSIONS: The results of this study indicate that rhAm-HAMA hydrogel could effectively promote the osteogenic differentiation of hPDLCs and stabilize bone substitutes in the defects that enhance the bone regeneration in vivo.


Asunto(s)
Amelogenina , Regeneración Ósea , Diferenciación Celular , Proliferación Celular , Ácido Hialurónico , Hidrogeles , Ligamento Periodontal , Ratas Sprague-Dawley , Ácido Hialurónico/farmacología , Animales , Regeneración Ósea/efectos de los fármacos , Amelogenina/farmacología , Amelogenina/uso terapéutico , Humanos , Ligamento Periodontal/efectos de los fármacos , Ratas , Proliferación Celular/efectos de los fármacos , Diferenciación Celular/efectos de los fármacos , Proteínas Recombinantes/farmacología , Proteínas Recombinantes/uso terapéutico , Osteogénesis/efectos de los fármacos , Masculino , Microtomografía por Rayos X , Células Cultivadas , Metacrilatos , Materiales Biocompatibles/farmacología
11.
Nutr Metab Cardiovasc Dis ; 34(6): 1508-1517, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38503620

RESUMEN

BACKGROUND AND AIMS: Uric acid (UA) and C-reactive protein (CRP) may interact synergistically to accelerate the initiation and progression of cardiovascular disease (CVD). This study investigated the effects of a combination of high UA and high CRP on the risks of CVD. METHODS AND RESULTS: A total of 90,270 participants recruited from the Kailuan study were included, who were divided into four groups according to the presence/absence of hyperuricemia and inflammation. Cox regression was applied to evaluate the hazard ratios (HRs) and 95% confidence intervals (95% CIs) of CVD. C-statistics, net classification index (NRI), and integrated discrimination improvement (IDI) were used to compare the incremental predictive of UA, CRP, and their combined effects on CVD. Mediation analysis was to explore the impact of CRP on the association between UA and CVD. Over a median follow-up of 14.95 years, we identified 11398 incident CVD cases. Compared to the low UA/low CRP group, the high UA/low CRP, low UA/high CRP and high UA/high CRP groups showed progressively higher risks of CVD, HR (95% CI): 1.18(1.10-1.27), 1.27(1.21-1.33) and 1.50 (1.33-1.69), respectively. The incorporation of UA and CRP into the traditional China-PAR model led to improvement in the C-statistic, NRI, and IDI, and was better than incorporation of either UA or CRP alone. Mediation analysis showed that CRP mediated the association between UA and CVD, accounting for 11.57% of the total effects. CONCLUSIONS: High UA/high CRP is associated with increased risks of CVD. Incorporation of both UA and CRP provided additional value for risk stratification.


Asunto(s)
Biomarcadores , Proteína C-Reactiva , Enfermedades Cardiovasculares , Factores de Riesgo de Enfermedad Cardiaca , Hiperuricemia , Mediadores de Inflamación , Regulación hacia Arriba , Ácido Úrico , Humanos , Proteína C-Reactiva/análisis , Ácido Úrico/sangre , Masculino , Enfermedades Cardiovasculares/epidemiología , Enfermedades Cardiovasculares/sangre , Enfermedades Cardiovasculares/diagnóstico , Persona de Mediana Edad , Femenino , Estudios Prospectivos , Biomarcadores/sangre , China/epidemiología , Medición de Riesgo , Hiperuricemia/sangre , Hiperuricemia/epidemiología , Hiperuricemia/diagnóstico , Factores de Tiempo , Adulto , Incidencia , Mediadores de Inflamación/sangre , Pronóstico , Anciano , Análisis de Mediación
12.
Radiology ; 307(5): e221408, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37367448

RESUMEN

Background Current guidelines recommend the use of conventional US for risk stratification and management of thyroid nodules. However, fine-needle aspiration (FNA) is often recommended in benign nodules. Purpose To compare the diagnostic performance of multimodality US (including conventional US, strain elastography, and contrast-enhanced US [CEUS]) with the American College of Radiology Thyroid Imaging Reporting and Data System (TI-RADS) in the recommendation of FNA for thyroid nodules to reduce unnecessary biopsies. Materials and Methods In this prospective study, 445 consecutive participants with thyroid nodules from nine tertiary referral hospitals were recruited between October 2020 and May 2021. With univariable and multivariable logistic regression, the prediction models incorporating sonographic features, evaluated with interobserver agreement, were constructed and internally validated with bootstrap resampling technique. In addition, discrimination, calibration, and decision curve analysis were performed. Results A total of 434 thyroid nodules confirmed at pathologic analysis (259 malignant thyroid nodules) in 434 participants (mean age, 45 years ± 12 [SD]; 307 female participants) were included. Four multivariable models incorporated participant age, nodule features at US (proportion of cystic components, echogenicity, margin, shape, punctate echogenic foci), elastography features (stiffness), and CEUS features (blood volume). In recommending FNA in thyroid nodules, the highest area under the receiver operating characteristic curve (AUC) was 0.85 (95% CI: 0.81, 0.89) for the multimodality US model, and the lowest AUC was 0.63 (95% CI: 0.59, 0.68) for TI-RADS (P < .001). At the 50% risk threshold, 31% (95% CI: 26, 38) of FNA procedures could be avoided with multimodality US compared with 15% (95% CI: 12, 19) with TI-RADS (P < .001). Conclusion Multimodality US had better performance in recommending FNA to avoid unnecessary biopsies than the TI-RADS. Clinical trial registration no. NCT04574258 © RSNA, 2023 Supplemental material is available for this article.


Asunto(s)
Nódulo Tiroideo , Adulto , Femenino , Humanos , Persona de Mediana Edad , Biopsia con Aguja Fina , Imagen Multimodal , Estudios Prospectivos , Nódulo Tiroideo/diagnóstico por imagen , Nódulo Tiroideo/patología , Ultrasonografía/métodos
13.
Radiology ; 307(3): e220661, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36880949

RESUMEN

Background Microwave ablation (MWA) has achieved favorable results in the treatment of papillary thyroid microcarcinoma (PTMC) confined in glandular parenchyma. However, studies on the outcome of MWA for PTMC with US-detected capsular invasion remain unclarified in the literature. Purpose To compare the feasibility, effectiveness, and safety of MWA in the treatment of PTMC with and without US-detected capsular invasion. Materials and Methods Participants from 12 hospitals with a PTMC maximal diameter of 1 cm or less without US- or CT-detected lymph node metastasis (LNM) who planned to undergo MWA were enrolled in this prospective study between December 2019 and April 2021. All tumors were evaluated with preoperative US and were divided into those with and those without capsular invasion. The participants were observed until July 1, 2022. The primary end points, including technical success and disease progression, and the secondary end points, including treatment parameters, complications, and tumor shrinkage during follow-up, were compared between the two groups, and multivariable regression was performed. Results After exclusion, 461 participants (mean age, 43 years ± 11 [SD]; 337 women) were included: 83 with and 378 without capsular invasion. After one participant with capsular invasion aborted MWA because of technical failure, 82 participants with and 378 participants without capsular invasion (mean tumor volume, 0.1 mL ± 0.1 vs 0.1 mL ± 0.1; P = .07) were analyzed with a mean follow-up period of 20 months ± 4 (range, 12-25 months) and 21 months ± 4 (range, 11-26 months), respectively. In those with and those without capsular invasion, comparable technical success rates were achieved (99% [82 of 83] vs 100% [378 of 378], P = .18), with one and 11 complications, respectively (1% [one of 82] vs 3% [11 of 378], P = .38). There was no evidence of differences in disease progression (2% [one of 82] vs 1% [four of 378]; P = .82) or tumor shrinkage (mean, 97% ± 8 [SD] vs 96% ± 13; P = .58). Conclusion Microwave ablation was feasible in the treatment of papillary thyroid microcarcinoma with US-detected capsular invasion and showed comparable short-term efficacy with or without the presence of capsular invasion. © RSNA, 2023 Clinical trial registration no. NCT04197960 Supplemental material is available for this article.


Asunto(s)
Ablación por Radiofrecuencia , Neoplasias de la Tiroides , Humanos , Femenino , Adulto , Estudios Prospectivos , Microondas/uso terapéutico , Neoplasias de la Tiroides/patología , Ablación por Radiofrecuencia/métodos , Estudios Retrospectivos
14.
Opt Express ; 31(6): 10840-10861, 2023 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-37157621

RESUMEN

An intermodal-nonlinearity-induced time-frequency evolution model of high-power near-single-mode continuous-wave fiber lasers (NSM-CWHPFLs) was proposed to simulate the evolution of spectral characteristics and beam quality under the combined action of intermodal and intramodal nonlinear effects. The influence of fiber laser parameters on intermodal nonlinearities was analyzed, and a suppression method involving fiber coiling and seed mode characteristic optimization was proposed. Verification experiments were conducted with 20/400, 25/400, and 30/600 fiber-based NSM-CWHPFLs. The results demonstrate the accuracy of the theoretical model, clarify the physical mechanisms of nonlinear spectral sidebands, and demonstrate the comprehensive optimization of intermodal-nonlinearity-induced spectral distortion and mode degradation.

15.
Opt Express ; 31(17): 28320-28337, 2023 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-37710889

RESUMEN

To realize deep space optical communications with high capacity and sensitivity, synchronization of pulse-position modulation (PPM) signals is crucial. In this study, the maximum likelihood synchronization algorithm based on inter-symbol guard times was generalized to the scenario with strong blockage of single-photon detectors, where higher PPM slot frequency and signal-noise ratio could be adopted. Furthermore, a slot frequency offset compensation method was proposed, and simulations and experiments were performed to verify the performance improvement of the proposed corrected synchronization algorithm under blockage. The results indicated that the deadtime-corrected synchronization scheme could effectively overcome the performance degradation of the original model under high photon flux, provide estimation (0.02749 slots @ root-mean-square error) close to the Cramér-Rao Bound, and error rates close to ideal synchronization in the experiment.

16.
Opt Lett ; 48(23): 6228-6231, 2023 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-38039233

RESUMEN

We demonstrate a pulsed mid-infrared (MIR) optical parametric oscillator (OPO) with both inter-pulse and intra-pulse dual-wavelength operation capability. A fiber master oscillator power amplifier incorporating an acousto-optic tunable filter (AOTF) was employed as the pump for the OPO. By finely adjusting the drive wave packets for the AOTF, dual-wavelength pump can be realized within each pulse or between two adjacent pulses. These special temporal-spectral behaviors of the pump can be transferred to MIR via an OPO. In the proof-of-principle experiments, two pump wavelengths at ∼1065 and ∼1076 nm were generated and amplified to ∼31.2 W with equivalent spectral intensities for both pulsation modes. At the highest pump power, total idler power of ∼3.5 W was achieved at ∼3.45 and ∼3.55 µm under both pulsation modes. To the best of our knowledge, this is the first demonstration of both inter-pulse and intra-pulse dual-wavelength MIR generation via an OPO with an identical configuration. It is believed that our design may provide a promising solution to many practical applications including differential absorption lidar and tunable terahertz wave generation.

17.
Langmuir ; 39(37): 13371-13385, 2023 Sep 19.
Artículo en Inglés | MEDLINE | ID: mdl-37675482

RESUMEN

Profiting from their slippery nature, lubricant-infused porous surfaces endow with droplets excellent mobility and consequently promise remarkable heat transfer improvement for dropwise condensation. To be a four-phase wetting system, the droplet wettability configurations and the corresponding dynamic characteristics on lubricant-infused porous surfaces are closely related to many factors, such as multiple interfacial interactions, surface features, and lubricant thickness, which keeps a long-standing challenge to promulgate the underlying physics. In this work, thermodynamically theoretical analysis and three-dimensional molecular dynamics simulations with the coarse-grained water and hexane models are carried out to explore droplet wettability and mobility on lubricant-infused porous surfaces. Combined with accessible theoretical criteria, phase diagrams of droplet configurations are constructed with a comprehensive consideration of interfacial interactions, surface structures, and lubricant thickness. Subsequently, droplet sliding and coalescence dynamics are quantitatively defined under different configurations. Finally, in terms of the promotion of dropwise condensation, a non-cloaking configuration with the encapsulated state underneath the droplet is recommended to achieve high droplet mobility owing to the low viscous drag of the lubricant and the eliminated pinning effect of the contact line. On the basis of the low oil-water and water-solid interactions, a stable lubricant layer with a relatively low thickness is suggested to construct slippery surfaces.

18.
Langmuir ; 39(51): 19037-19047, 2023 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-38096493

RESUMEN

Reducing the contact time during the droplet impact on the surface is crucial for anti-icing, self-cleaning, and heat transfer optimization applications. This study aims to minimize the contact time by modifying the surface curvature to create an asymmetric impact process. Our experiments showed that the increase in Weber numbers (We) and the decrease in the ratio of surface diameter to droplet diameter (D*) intensify the asymmetry of the impact process, yielding four distinct rebound modes. Low asymmetry observes the liquid retract toward the central point (Rebound Modes 1 and 2), whereas high asymmetry yields a wing-like rebound (Rebound Modes 3 and 4). In Rebound Mode 1, increased asymmetry would lead to more extended contact due to the prolonged waiting period. Conversely, the reduction in contact time in Rebound Mode 2 occurs due to increased asymmetry with no waiting period. For Rebound Modes 3 and 4, the retraction time could be divided into three stages, generated by two liquid detachment modes from the surface. Analysis reveals that an increased asymmetry would reduce the retraction time during the first stage but prolong it during the third stage, with no significant effects on the second. Four correlations, each pertaining to a distinct impact mode, are proposed based on these analyses to describe the contact time concerning We and D* for droplets impacting a superhydrophobic cylindrical surface.

19.
Eur Radiol ; 33(12): 8727-8735, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37466709

RESUMEN

OBJECTIVES: Microwave ablation (MWA) has been widely used for unifocal papillary thyroid carcinoma (U-PTC) and has recently been preliminarily used in multifocal papillary thyroid carcinoma (M-PTC). However, the efficacy and safety of MWA for M-PTC have not been investigated in large samples. The aim of the present study was to evaluate the efficacy and safety of MWA for M-PTC and compare them with MWA for U-PTC. MATERIALS AND METHODS: This retrospective multicentre study enrolled 504 patients (376 females) who underwent MWA for U-PTC (340 cases) or M-PTC (164 cases) from Jan 2015 to Dec 2020. The median age of the patients was 43 years (age range, 20-80 years). Propensity score matching (PSM) was used to balance the baseline characteristics between M-PTC group and U-PTC group. The tumour progression, tumour disappearance, and complication rates were compared between the two groups. RESULTS: The complete ablation was achieved in all enrolled cases in one session. According to the statistical results, no significant differences were shown in tumour progression-free survival (p  = 0.29) or cumulative tumour progression rate (6.7% vs. 4.3%, p  = 0.33) between the M-PTC and U-PTC groups during the follow-up time. However, the tumour disappearance rate in the M-PTC group was lower in the U-PTC group (40.9% vs. 62.8%, p < 0.001), and tumour disappearance was slower in the M-PTC group (p < 0.001). The complication rate showed no significant difference (3.0% vs. 4.9%, p  = 0.571). CONCLUSIONS: MWA is an effective and safe treatment for selected patients with M-PTC, and the prognosis is similar to that of U-PTC. CLINICAL RELEVANCE STATEMENT: The present study provided evidence that compared with unifocal papillary thyroid cancer, microwave ablation could also treat multifocal T1N0M0 papillary thyroid cancer safely with similar clinical outcome, which could promote the application of minimally invasive treatment for papillary thyroid cancer. KEY RESULTS: • Microwave ablation for multifocal and unifocal T1N0M0 papillary thyroid carcinoma had similar tumour progression rates after propensity score matching (6.7% vs. 4.3%, p = 0.33). • The tumour disappearance rate in the multifocal group was lower than that in the unifocal group (40.9% vs. 62.8%, p < 0.001), and tumour disappearance was slower in the multifocal group (p < 0.001). • Tumour size, number, and location were not risk factors for tumour progression in the multifocal papillary thyroid cancer group.


Asunto(s)
Carcinoma Papilar , Neoplasias de la Tiroides , Femenino , Humanos , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Cáncer Papilar Tiroideo/cirugía , Cáncer Papilar Tiroideo/patología , Neoplasias de la Tiroides/cirugía , Neoplasias de la Tiroides/patología , Estudios Retrospectivos , Resultado del Tratamiento , Microondas/uso terapéutico , Carcinoma Papilar/cirugía , Carcinoma Papilar/patología
20.
Eur Radiol ; 33(1): 233-243, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35771248

RESUMEN

OBJECTIVES: Minimal extrathyroid extension (mETE) was removed from the TNM staging system. This study was designed prospectively to compare the safety and efficacy of microwave ablation (MWA) versus surgery for treating T1N0M0 papillary thyroid carcinomas (PTC) with sonographically detected mETE. METHODS: From December 2019 to April 2021, 198 patients with T1N0M0 mETE-PTCs evaluated by preoperative ultrasound from 10 hospitals were included. Ninety-two patients elected MWA, and 106 patients elected surgery for treatment. MWA was performed using extensive ablation with hydrodissection. Surgery consisted of lobectomy with ipsilateral central lymph node dissection (CLD), lobe and isthmus excision with ipsilateral CLD and total thyroidectomy with ipsilateral CLD. The rates of technical success, cost, oncologic outcomes, complications and quality of life of the two groups were assessed. RESULTS: The follow-up times for the MWA and surgery groups were 12.7 ± 4.1 and 12.6 ± 5.0 months, respectively. The technical success rate was 100% for both groups. Oncological outcomes of the two groups were similar during the follow-up (all p > 0.05). The MWA group had a shorter operation time, less blood loss and lower costs (all p < 0.001). Three complications (3.3%) were reported in the MWA group and 4 (3.8%) in the surgery group (p = 0.846). The surgery group had higher scores for scar problems and anxiety (p < 0.001 and p = 0.003, respectively). CONCLUSIONS: Microwave ablation was comparable in the short term to surgery in terms of treatment safety and efficacy in selected patients with T1N0M0 mETE-PTC detected by ultrasound. KEY POINTS: • Microwave ablation is comparable to surgery in the safety and short-term efficacy for PTCs with sonographically detected mETE. • Thermal ablation is technically feasible for mETE-PTC treatment. • Patients with mETE-PTC have similar quality of life in the two groups, except for worse scar problems and anxiety in the surgery group.


Asunto(s)
Carcinoma Papilar , Neoplasias de la Tiroides , Humanos , Cáncer Papilar Tiroideo/cirugía , Carcinoma Papilar/cirugía , Carcinoma Papilar/patología , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/cirugía , Neoplasias de la Tiroides/patología , Estudios Prospectivos , Microondas/uso terapéutico , Cicatriz/patología , Calidad de Vida , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA