Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 113
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 91(5): 1803-1821, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38115695

RESUMEN

PURPOSE: K trans $$ {K}^{\mathrm{trans}} $$ has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for K trans $$ {K}^{\mathrm{trans}} $$ quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging-Dynamic Contrast-Enhanced (OSIPI-DCE) challenge was designed to benchmark methods to better help the efforts to standardize K trans $$ {K}^{\mathrm{trans}} $$ measurement. METHODS: A framework was created to evaluate K trans $$ {K}^{\mathrm{trans}} $$ values produced by DCE-MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for K trans $$ {K}^{\mathrm{trans}} $$ quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' K trans $$ {K}^{\mathrm{trans}} $$ values, the applied software, and a standard operating procedure. These were evaluated using the proposed OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score defined with accuracy, repeatability, and reproducibility components. RESULTS: Across the 10 received submissions, the OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0-1 = lowest-highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in K trans $$ {K}^{\mathrm{trans}} $$ analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility. CONCLUSIONS: This study reports results from the OSIPI-DCE challenge and highlights the high inter-software variability within K trans $$ {K}^{\mathrm{trans}} $$ estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real-world clinical setting, many of these tools may perform differently with different benchmarking methodology.


Asunto(s)
Medios de Contraste , Imagen por Resonancia Magnética , Humanos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Programas Informáticos , Algoritmos
2.
Magn Reson Med ; 89(2): 522-535, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36219464

RESUMEN

PURPOSE: To assess the reliability of measuring diffusivity, diffusional kurtosis, and cellular-interstitial water exchange time with long diffusion times (100-800 ms) using stimulated-echo DWI. METHODS: Time-dependent diffusion MRI was tested on two well-established diffusion phantoms and in 5 patients with head and neck cancer. Measurements were conducted using an in-house diffusion-weighted STEAM-EPI pulse sequence with multiple diffusion times at a fixed TE on three scanners. We used the weighted linear least-squares fit method to estimate time-dependent diffusivity, D ( t ) $$ D(t) $$ , and diffusional kurtosis, K ( t ) $$ K(t) $$ . Additionally, the Kärger model was used to estimate cellular-interstitial water exchange time ( τ ex $$ {\tau}_{ex} $$ ) from K ( t ) $$ K(t) $$ . RESULTS: Diffusivity measured by time-dependent STEAM-EPI measurements and commercial SE-EPI showed comparable results with R2 above 0.98 and overall 5.4 ± 3.0% deviation across diffusion times. Diffusional kurtosis phantom data showed expected patterns: constant D $$ D $$ and K $$ K $$  = 0 for negative controls and slow varying D $$ D $$ and K $$ K $$ for samples made of nanoscopic vesicles. Time-dependent diffusion MRI in patients with head and neck cancer found that the Kärger model could be considered valid in 72% ± 23% of the voxels in the metastatic lymph nodes. The median cellular-interstitial water exchange time estimated for lesions was between 58.5 ms and 70.6 ms. CONCLUSIONS: Based on two well-established diffusion phantoms, we found that time-dependent diffusion MRI measurements can provide stable diffusion and kurtosis values over a wide range of diffusion times and across multiple MRI systems. Moreover, estimation of cellular-interstitial water exchange time can be achieved using the Kärger model for the metastatic lymph nodes in patients with head and neck cancer.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Neoplasias de Cabeza y Cuello , Humanos , Reproducibilidad de los Resultados , Imagen de Difusión por Resonancia Magnética/métodos , Fantasmas de Imagen , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Agua
3.
J Magn Reson Imaging ; 55(6): 1745-1758, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34767682

RESUMEN

BACKGROUND: Diffusion-weighted imaging (DWI) is commonly used to detect prostate cancer, and a major clinical challenge is differentiating aggressive from indolent disease. PURPOSE: To compare 14 site-specific parametric fitting implementations applied to the same dataset of whole-mount pathologically validated DWI to test the hypothesis that cancer differentiation varies with different fitting algorithms. STUDY TYPE: Prospective. POPULATION: Thirty-three patients prospectively imaged prior to prostatectomy. FIELD STRENGTH/SEQUENCE: 3 T, field-of-view optimized and constrained undistorted single-shot DWI sequence. ASSESSMENT: Datasets, including a noise-free digital reference object (DRO), were distributed to the 14 teams, where locally implemented DWI parameter maps were calculated, including mono-exponential apparent diffusion coefficient (MEADC), kurtosis (K), diffusion kurtosis (DK), bi-exponential diffusion (BID), pseudo-diffusion (BID*), and perfusion fraction (F). The resulting parametric maps were centrally analyzed, where differentiation of benign from cancerous tissue was compared between DWI parameters and the fitting algorithms with a receiver operating characteristic area under the curve (ROC AUC). STATISTICAL TEST: Levene's test, P < 0.05 corrected for multiple comparisons was considered statistically significant. RESULTS: The DRO results indicated minimal discordance between sites. Comparison across sites indicated that K, DK, and MEADC had significantly higher prostate cancer detection capability (AUC range = 0.72-0.76, 0.76-0.81, and 0.76-0.80 respectively) as compared to bi-exponential parameters (BID, BID*, F) which had lower AUC and greater between site variation (AUC range = 0.53-0.80, 0.51-0.81, and 0.52-0.80 respectively). Post-processing parameters also affected the resulting AUC, moving from, for example, 0.75 to 0.87 for MEADC varying cluster size. DATA CONCLUSION: We found that conventional diffusion models had consistent performance at differentiating prostate cancer from benign tissue. Our results also indicated that post-processing decisions on DWI data can affect sensitivity and specificity when applied to radiological-pathological studies in prostate cancer. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 3.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Neoplasias de la Próstata , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Masculino , Estudios Prospectivos , Neoplasias de la Próstata/diagnóstico por imagen , Curva ROC , Estudios Retrospectivos , Sensibilidad y Especificidad
4.
J Magn Reson Imaging ; 53(2): 347-359, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32302044

RESUMEN

MRI has played a critical role in the evaluation of patients with pancreatic pathologies, from screening of patients at high risk for pancreatic cancer to the evaluation of pancreatic cysts and indeterminate pancreatic lesions. The high mortality associated with pancreatic adenocarcinomas has spurred much interest in developing effective screening tools, with MRI using magnetic resonance cholangiopancreatography (MRCP) playing a central role in the hopes of identifying cancers at earlier stages amenable to curative resection. Ongoing efforts to improve the resolution and robustness of imaging of the pancreas using MRI may thus one day reduce the mortality of this deadly disease. However, the increasing use of cross-sectional imaging has also generated a concomitant clinical conundrum: How to manage incidental pancreatic cystic lesions that are found in over a quarter of patients who undergo MRCP. Efforts to improve the specificity of MRCP for patients with pancreatic cysts and with indeterminate pancreatic masses may be achieved with continued technical advances in MRI, including diffusion-weighted and T1 -weighted dynamic contrast-enhanced MRI. However, developments in quantitative MRI of the pancreas remain challenging, due to the small size of the pancreas and its upper abdominal location, adjacent to bowel and below the diaphragm. Further research is needed to improve MRI of the pancreas as a clinical tool, to positively affect the lives of patients with pancreatic abnormalities. This review focuses on various MR techniques such as MRCP, quantitative imaging, and dynamic contrast-enhanced imaging and their clinical applicability in the imaging of the pancreas, with an emphasis on pancreatic malignant and premalignant lesions. Level of Evidence 5 Technical Efficacy Stage 3 J. MAGN. RESON. IMAGING 2021;53:347-359.


Asunto(s)
Adenocarcinoma , Neoplasias Pancreáticas , Pancreatocolangiografía por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética , Páncreas/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico por imagen
5.
Breast Cancer Res ; 22(1): 58, 2020 05 28.
Artículo en Inglés | MEDLINE | ID: mdl-32466799

RESUMEN

BACKGROUND: Ultrafast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI)-derived kinetic parameters have demonstrated at least equivalent accuracy to standard DCE-MRI in differentiating malignant from benign breast lesions. However, it is unclear if they have any efficacy as prognostic imaging markers. The aim of this study was to investigate the relationship between ultrafast DCE-MRI-derived kinetic parameters and breast cancer characteristics. METHODS: Consecutive breast MRI examinations between February 2017 and January 2018 were retrospectively reviewed to determine those examinations that meet the following inclusion criteria: (1) BI-RADS 4-6 MRI performed on a 3T scanner with a 16-channel breast coil and (2) a hybrid clinical protocol with 15 phases of ultrafast DCE-MRI (temporal resolution of 2.7-4.6 s) followed by early and delayed phases of standard DCE-MRI. The study included 125 examinations with 142 biopsy-proven breast cancer lesions. Ultrafast DCE-MRI-derived kinetic parameters (maximum slope [MS] and bolus arrival time [BAT]) were calculated for the entire volume of each lesion. Comparisons of these parameters between different cancer characteristics were made using generalized estimating equations, accounting for the presence of multiple lesions per patient. All comparisons were exploratory and adjustment for multiple comparisons was not performed; P values < 0.05 were considered statistically significant. RESULTS: Significantly larger MS and shorter BAT were observed for invasive carcinoma than ductal carcinoma in situ (DCIS) (P < 0.001 and P = 0.008, respectively). Significantly shorter BAT was observed for invasive carcinomas with more aggressive characteristics than those with less aggressive characteristics: grade 3 vs. grades 1-2 (P = 0.025), invasive ductal carcinoma vs. invasive lobular carcinoma (P = 0.002), and triple negative or HER2 type vs. luminal type (P < 0.001). CONCLUSIONS: Ultrafast DCE-MRI-derived parameters showed a strong relationship with some breast cancer characteristics, especially histopathology and molecular subtype.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Adulto , Anciano , Neoplasias de la Mama/patología , Neoplasias de la Mama/terapia , Carcinoma Ductal de Mama/diagnóstico por imagen , Carcinoma Ductal de Mama/patología , Carcinoma Ductal de Mama/terapia , Carcinoma Lobular/diagnóstico por imagen , Carcinoma Lobular/patología , Carcinoma Lobular/terapia , Medios de Contraste , Femenino , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética/métodos , Persona de Mediana Edad , Pronóstico , Estudios Retrospectivos , Adulto Joven
6.
NMR Biomed ; 33(1): e4166, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31680360

RESUMEN

The purpose of this study was to identify the optimal tracer kinetic model from T1 -weighted dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) data and evaluate whether parameters estimated from the optimal model predict tumor aggressiveness determined from histopathology in patients with papillary thyroid carcinoma (PTC) prior to surgery. In this prospective study, 18 PTC patients underwent pretreatment DCE-MRI on a 3 T MR scanner prior to thyroidectomy. This study was approved by the institutional review board and informed consent was obtained from all patients. The two-compartment exchange model, compartmental tissue uptake model, extended Tofts model (ETM) and standard Tofts model were compared on a voxel-wise basis to determine the optimal model using the corrected Akaike information criterion (AICc) for PTC. The optimal model is the one with the lowest AICc. Statistical analysis included paired and unpaired t-tests and a one-way analysis of variance. Bonferroni correction was applied for multiple comparisons. Receiver operating characteristic (ROC) curves were generated from the optimal model parameters to differentiate PTC with and without aggressive features, and AUCs were compared. ETM performed best with the lowest AICc and the highest Akaike weight (0.44) among the four models. ETM was preferred in 44% of all 3419 voxels. The ETM estimates of Ktrans in PTCs with the aggressive feature extrathyroidal extension (ETE) were significantly higher than those without ETE (0.78 ± 0.29 vs. 0.34 ± 0.18 min-1 , P = 0.005). From ROC analysis, cut-off values of Ktrans , ve and vp , which discriminated between PTCs with and without ETE, were determined at 0.45 min-1 , 0.28 and 0.014 respectively. The sensitivities and specificities were 86 and 82% (Ktrans ), 71 and 82% (ve ), and 86 and 55% (vp ), respectively. Their respective AUCs were 0.90, 0.71 and 0.71. We conclude that ETM Ktrans has shown potential to classify tumors with and without aggressive ETE in patients with PTC.


Asunto(s)
Medios de Contraste/química , Imagen por Resonancia Magnética , Cáncer Papilar Tiroideo/diagnóstico por imagen , Cáncer Papilar Tiroideo/patología , Neoplasias de la Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/patología , Adulto , Anciano , Femenino , Humanos , Cinética , Masculino , Persona de Mediana Edad , Invasividad Neoplásica , Factores de Tiempo
7.
Eur Radiol ; 30(2): 756-766, 2020 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-31468162

RESUMEN

OBJECTIVES: This study aims to evaluate ultrafast DCE-MRI-derived kinetic parameters that reflect contrast agent inflow effects in differentiating between subcentimeter BI-RADS 4-5 breast carcinomas and benign lesions. METHODS: We retrospectively reviewed consecutive 3-T MRI performed from February to October 2017, during which ultrafast DCE-MRI was performed as part of a hybrid clinical protocol with conventional DCE-MRI. In total, 301 female patients with 369 biopsy-proven breast lesions were included. Ultrafast DCE-MRI was acquired continuously over approximately 60 s (temporal resolution, 2.7-7.1 s/phase) starting simultaneously with the start of contrast injection. Four ultrafast DCE-MRI-derived kinetic parameters (maximum slope [MS], contrast enhancement ratio [CER], bolus arrival time [BAT], and initial area under gadolinium contrast agent concentration [IAUGC]) and one conventional DCE-MRI-derived kinetic parameter (signal enhancement ratio [SER]) were calculated for each lesion. Wilcoxon rank sum test or Fisher's exact test was performed to compare kinetic parameters, volume, diameter, age, and BI-RADS morphological descriptors between subcentimeter carcinomas and benign lesions. Univariate/multivariate logistic regression analyses were performed to determine predictive parameters for subcentimeter carcinomas. RESULTS: In total, 125 lesions (26 carcinomas and 99 benign lesions) were identified as BI-RADS 4-5 subcentimeter lesions. Subcentimeter carcinomas demonstrated significantly larger MS and SER and shorter BAT than benign lesions (p = 0.0117, 0.0046, and 0.0102, respectively). MS, BAT, and age were determined as significantly predictive for subcentimeter carcinoma (p = 0.0208, 0.0023, and < 0.0001, respectively). CONCLUSIONS: Ultrafast DCE-MRI-derived kinetic parameters may be useful in differentiating subcentimeter BI-RADS 4 and 5 carcinomas from benign lesions. KEY POINTS: • Ultrafast DCE-MRI can generate kinetic parameters, effectively differentiating breast carcinomas from benign lesions. • Subcentimeter carcinomas demonstrated significantly larger maximum slope and shorter bolus arrival time than benign lesions. • Maximum slope and bolus arrival time contribute to better management of suspicious subcentimeter breast lesions.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Medios de Contraste , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Adulto , Mama/diagnóstico por imagen , Mama/patología , Neoplasias de la Mama/patología , Diagnóstico Diferencial , Femenino , Humanos , Cinética , Persona de Mediana Edad , Estudios Retrospectivos
8.
Magn Reson Med ; 82(6): 2314-2325, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31273818

RESUMEN

PURPOSE: Current state-of-the-art models for estimating the pharmacokinetic parameters do not account for intervoxel movement of the contrast agent (CA). We introduce an optimal mass transport (OMT) formulation that naturally handles intervoxel CA movement and distinguishes between advective and diffusive flows. METHOD: Ten patients with head and neck squamous cell carcinoma (HNSCC) were enrolled in the study between June 2014 and October 2015 and underwent DCE MRI imaging prior to beginning treatment. The CA tissue concentration information was taken as the input in the data-driven OMT model. The OMT approach was tested on HNSCC DCE data that provides quantitative information for forward flux ( ΦF ) and backward flux ( ΦB ). OMT-derived ΦF was compared with the volume transfer constant for CA, Ktrans , derived from the Extended Tofts Model (ETM). RESULTS: The OMT-derived flows showed a consistent jump in the CA diffusive behavior across the images in accordance with the known CA dynamics. The mean forward flux was 0.0082 ± 0.0091 ( min-1 ) whereas the mean advective component was 0.0052 ± 0.0086 ( min-1 ) in the HNSCC patients. The diffusive percentages in forward and backward flux ranged from 8.67% to 18.76% and 12.76% to 30.36%, respectively. The OMT model accounts for intervoxel CA movement and results show that the forward flux ( ΦF ) is comparable with the ETM-derived Ktrans . CONCLUSIONS: This is a novel data-driven study based on optimal mass transport principles applied to patient DCE imaging to analyze CA flow in HNSCC.


Asunto(s)
Carcinoma de Células Escamosas/diagnóstico por imagen , Medios de Contraste/farmacocinética , Imagen de Difusión por Resonancia Magnética , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Carcinoma de Células Escamosas/virología , Gadolinio DTPA/farmacocinética , Neoplasias de Cabeza y Cuello/virología , Humanos , Cinética , Modelos Teóricos , Infecciones por Papillomavirus/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos , Resultado del Tratamiento
9.
J Magn Reson Imaging ; 49(7): e101-e121, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30451345

RESUMEN

Physiological properties of tumors can be measured both in vivo and noninvasively by diffusion-weighted imaging and dynamic contrast-enhanced magnetic resonance imaging. Although these techniques have been used for more than two decades to study tumor diffusion, perfusion, and/or permeability, the methods and studies on how to reduce measurement error and bias in the derived imaging metrics is still lacking in the literature. This is of paramount importance because the objective is to translate these quantitative imaging biomarkers (QIBs) into clinical trials, and ultimately in clinical practice. Standardization of the image acquisition using appropriate phantoms is the first step from a technical performance standpoint. The next step is to assess whether the imaging metrics have clinical value and meet the requirements for being a QIB as defined by the Radiological Society of North America's Quantitative Imaging Biomarkers Alliance (QIBA). The goal and mission of QIBA and the National Cancer Institute Quantitative Imaging Network (QIN) initiatives are to provide technical performance standards (QIBA profiles) and QIN tools for producing reliable QIBs for use in the clinical imaging community. Some of QIBA's development of quantitative diffusion-weighted imaging and dynamic contrast-enhanced QIB profiles has been hampered by the lack of literature for repeatability and reproducibility of the derived QIBs. The available research on this topic is scant and is not in sync with improvements or upgrades in MRI technology over the years. This review focuses on the need for QIBs in oncology applications and emphasizes the importance of the assessment of their reproducibility and repeatability. Level of Evidence: 5 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2019;49:e101-e121.


Asunto(s)
Biomarcadores , Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias/diagnóstico por imagen , Adulto , Anciano , Encéfalo/diagnóstico por imagen , Ensayos Clínicos como Asunto , Medios de Contraste , Femenino , Humanos , Hígado/diagnóstico por imagen , Masculino , Oncología Médica/normas , Persona de Mediana Edad , Estudios Multicéntricos como Asunto , Neuroimagen/métodos , Fantasmas de Imagen , Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados
11.
Eur Radiol ; 29(8): 3976-3985, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30689033

RESUMEN

PURPOSE: To develop and optimize a rapid magnetic resonance imaging (MRI) screening protocol for pancreatic cancer to be performed in conjunction with breast MRI screening in breast cancer susceptibility gene (BRCA)-positive individuals. METHODS: An IRB-approved prospective study was conducted. The rapid screening pancreatic MR protocol was designed to be less than 10 min to be performed after a standard breast MRI protocol. Protocol consisted of coronal NT T2 SSFSE, axial NT T2 SSFSE and axial NT rFOV FOCUS DWI, and axial T1. Images were acquired with the patient in the same prone position of breast MRI using the built-in body coil. Image quality was qualitatively assessed by two radiologists with 12 and 13 years of MRI experience, respectively. The imaging protocol was modified until an endpoint of five consecutive patients with high-quality diagnostic images were achieved. Signal-to-noise ratio and contrast-to-noise ratio were assessed. RESULTS: The rapid pancreas MR protocol was successfully completed in all patients. Diagnostic image quality was achieved for all patients. Excellent image quality was achieved for low b values; however, image quality at higher b values was more variable. In one patient, a pancreatic neuroendocrine tumor was found and the patient was treated surgically. In four patients, small pancreatic cystic lesions were detected. In one subject, a hepatic mass was identified and confirmed as adenoma by liver MRI. CONCLUSION: Rapid MR protocol for pancreatic cancer screening is feasible and has the potential to play a role in screening BRCA patients undergoing breast MRI. KEY POINT: • Develop and optimize a rapid magnetic resonance imaging (MRI) screening protocol for pancreatic cancer to be performed in conjunction with breast MRI screening in BRCA mutation positive individuals.


Asunto(s)
Proteína BRCA1/genética , ADN de Neoplasias/genética , Detección Precoz del Cáncer/métodos , Imagen por Resonancia Magnética/métodos , Mutación , Neoplasias Pancreáticas/diagnóstico , Adulto , Anciano , Proteína BRCA1/metabolismo , Femenino , Humanos , Persona de Mediana Edad , Neoplasias Pancreáticas/genética , Neoplasias Pancreáticas/metabolismo , Proyectos Piloto , Estudios Prospectivos
12.
J Neurooncol ; 140(2): 351-358, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30073640

RESUMEN

PURPOSE: Prediction of clinical outcomes in patients with primary central nervous system lymphoma (PCNSL) is important for optimization of treatment planning. Quantitative imaging biomarkers for PCNSL have not yet been established. This study evaluated the prognostic value of pretreatment dynamic contrast-enhanced MRI and diffusion-weighted imaging for progression-free survival (PFS) in patients with PCNSL. METHODS: Pretreatment dynamic contrast-enhanced MRI and diffusion-weighted imaging were retrospectively analyzed in 18 immunocompetent patients with PCNSL. Volumes of interest encompassing the tumors were assessed for measurements of blood plasma volume (Vp), volume transfer constant (Ktrans), and apparent diffusion coefficient. Patients were divided into short and long PFS groups based on median PFS. Imaging and clinical variables were correlated with PFS. RESULTS: Median PFS was 19.6 months. Lower Vpmean and Ktransmean values increased risk for rapid progression (< 19.6 months). Receiver operating characteristic curve analysis demonstrated an optimal Vpmean cutoff value of 2.29 (area under the curve [AUC] = 0.74, sensitivity and specificity = 0.78, p = 0.023) for separating patients with short and long PFS. The optimal Ktransmean cutoff was 0.08 (AUC = 0.74, sensitivity = 0.67, specificity = 0.78, p = 0.025). Kaplan-Meier survival analysis with log-rank test demonstrated significantly (p = 0.015) increased risk of rapid progression for patients with Vpmean < 2.29. Vpmean was significantly (p = 0.03) associated with PFS on univariate Cox analysis. Apparent diffusion coefficient values and clinical factors did not influence PFS. CONCLUSIONS: Pretreatment Vp and Ktrans derived from dynamic contrast-enhanced MRI may be novel prognostic quantitative imaging biomarkers of progression-free survival in patients with PCNSL. These data should be prospectively validated in larger patient cohorts.


Asunto(s)
Neoplasias del Sistema Nervioso Central/diagnóstico por imagen , Medios de Contraste , Linfoma/diagnóstico por imagen , Imagen por Resonancia Magnética , Anciano , Anciano de 80 o más Años , Encéfalo/diagnóstico por imagen , Neoplasias del Sistema Nervioso Central/terapia , Femenino , Humanos , Linfoma/terapia , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Pronóstico , Supervivencia sin Progresión , Estudios Retrospectivos , Factores de Tiempo
13.
Am J Pathol ; 186(12): 3131-3145, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27770613

RESUMEN

Increased polyamine synthesis is known to play an important role in prostate cancer. We aimed to explore its functional significance in prostate tumor initiation and its link to androgen receptor (AR) signaling. For this purpose, we generated a new cell line derived from normal epithelial prostate cells (RWPE-1) with overexpression of ornithine decarboxylase (ODC) and used it for in vitro and in vivo experiments. We then comprehensively analyzed the expression of the main metabolic enzymes of the polyamine pathway and spermine abundance in 120 well-characterized cases of human prostate cancer and high-grade prostate intraepithelial neoplasia (HGPIN). Herein, we show that the ODC-overexpressing prostate cells underwent malignant transformation, revealing that ODC is sufficient for de novo tumor initiation in 94% of injected mice. This oncogenic capacity was acquired through alteration of critical signaling networks, including AR, EIF2, and mTOR/MAPK. RNA silencing experiments revealed the link between AR signaling and polyamine metabolism. Human prostate cancers consistently demonstrated up-regulation of the main polyamine enzymes analyzed (ODC, polyamine oxidase, and spermine synthase) and reduction of spermine. This phenotype was also dominant in HGPIN, rendering it a new biomarker of malignant transformation. In summary, we report that ODC plays a key role in prostate tumorigenesis and that the polyamine pathway is altered as early as HGPIN.


Asunto(s)
Ornitina Descarboxilasa/metabolismo , Neoplasia Intraepitelial Prostática/enzimología , Neoplasias de la Próstata/enzimología , Receptores Androgénicos/metabolismo , Transducción de Señal , Adulto , Anciano , Animales , Carcinogénesis , Línea Celular , Estudios de Cohortes , Expresión Génica , Regulación Neoplásica de la Expresión Génica , Humanos , Masculino , Ratones , Persona de Mediana Edad , Oxidorreductasas actuantes sobre Donantes de Grupo CH-NH/metabolismo , Poliaminas/metabolismo , Próstata/enzimología , Próstata/patología , Neoplasia Intraepitelial Prostática/etiología , Neoplasia Intraepitelial Prostática/patología , Neoplasias de la Próstata/etiología , Neoplasias de la Próstata/patología , Poliamino Oxidasa
15.
J Magn Reson Imaging ; 45(4): 1013-1023, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-27862553

RESUMEN

PURPOSE: Characterize and monitor treatment response in human papillomavirus (HPV) head and neck squamous cell carcinoma (HNSCC) using intra-treatment (intra-TX) imaging metrics derived from intravoxel incoherent motion (IVIM) diffusion-weighted magnetic resonance imaging (DW-MRI). MATERIALS AND METHODS: Thirty-four (30 HPV positive [+] and 4 HPV negative [-]) HNSCC patients underwent a total of 136 MRI including multi-b value DW-MRI (pretreatment [pre-TX] and intra-TX weeks 1, 2, and 3) at 3.0 Tesla. All patients were treated with chemo-radiation therapy. Monoexponential (yielding apparent diffusion coefficient [ADC]) and bi-exponential (yielding perfusion fraction [f], diffusion [D], and pseudo-diffusion [D*] coefficients) fits were performed on a region of interest and voxel-by-voxel basis, on metastatic neck nodes. Response was assessed using RECISTv1.1. The relative percentage change in D, f, and D* between the pre- and intra-TX weeks were used for hierarchical clustering. A Wilcoxon rank-sum test was performed to assess the difference in metrics within and between the complete response (CR) and non-CR groups. RESULTS: The delta (Δ) change in volume (V)1wk-0wk for the CR group differed significantly (P = 0.016) from the non-CR group, while not for V2wk-0wk and V3wk-0wk (P > 0.05). The mean increase in ΔD3wk-0wk for the CR group was significantly higher (P = 0.017) than the non-CR group. ADC and D showed an increasing trend at each intra-TX week when compared with pre-TX in CR group (P < 0.003). Hierarchical clustering demonstrated the existence of clusters in HPV + patients. CONCLUSION: After appropriate validation in a larger population, these IVIM imaging metrics may be useful for individualized treatment in HNSCC patients. LEVEL OF EVIDENCE: 2 J. Magn. Reson. Imaging 2017;45:1013-1023.


Asunto(s)
Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/terapia , Quimioradioterapia/métodos , Imagen de Difusión por Resonancia Magnética/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/terapia , Infecciones por Papillomavirus/diagnóstico por imagen , Infecciones por Papillomavirus/terapia , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Papillomaviridae , Estudios Prospectivos , Carcinoma de Células Escamosas de Cabeza y Cuello , Resultado del Tratamiento
16.
J Comput Assist Tomogr ; 41(6): 995-1001, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28708732

RESUMEN

OBJECTIVE: The aim of this study was to determine if optimized imaging protocols across multiple computed tomography (CT) vendors could result in reproducible radiomic features calculated from an anthropomorphic phantom. METHODS: Materials with varying degrees of heterogeneity were placed throughout the lungs of the phantom. Twenty scans of the phantom were acquired on 3 CT manufacturers with chest CT protocols that had optimized protocol parameters. Scans were reconstructed using vendor-specific standards and lung kernels. The concordance correlation coefficient (CCC) was used to calculate reproducibility between features. For features with high CCC values, Bland-Altman analysis was also used to quantify agreement. RESULTS: The mean Hounsfield unit (HU) was 32.93 HU (141.7 to -26.5 HU) for the rubber insert and 347.2 HU (-320.9 to -347.7 HU) for the wood insert. Low CCC values of less than 0.9 were calculated for all features across all scans. CONCLUSIONS: Radiomic features that are derived from the spatial distribution of voxel intensities should be particularly scrutinized for reproducibility in a multivendor environment.


Asunto(s)
Fantasmas de Imagen , Tomógrafos Computarizados por Rayos X , Tomografía Computarizada por Rayos X , Humanos , Pulmón , Reproducibilidad de los Resultados
17.
Cancer ; 122(17): 2708-14, 2016 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-27219108

RESUMEN

BACKGROUND: The purpose of this study was to investigate the utility and clinical impact of second-opinion interpretations of outside neuroimaging studies by oncologic neuroradiologists at a National Cancer Institute-designated cancer center. METHODS: We performed a retrospective analysis of initial outside and second-opinion radiology reports from 300 computed tomography and magnetic resonance imaging studies and identified cases with discrepancies between the two reports. An adult neuro-oncologist, pediatric neuro-oncologist, and head and neck surgeon reviewed each pair of discrepant reports based on their area of expertise, patient age, and the type of study performed. The clinicians were blinded to the origin of each report and recorded whether the differences in the reports would have led to a change in patient management and/or disease staging. Histopathologic analysis, clinical assessment, and/or minimum 3-month imaging follow-up served as the reference standards to establish which of the 2 reports was correct. RESULTS: Among the 283 cases that met our study criteria, there were 55 neuroimaging studies with disagreements (19%) between the initial outside report and second-opinion interpretation. Patient management and/or disease stage would have been altered in 42 of 283 cases (15%) based on report differences as determined by the 2 neuro-oncologists and the surgeon participating in the study. Sufficient follow-up was available in 35 of 42 cases (83%). The second-opinion interpretation was correct 100% of the time (35/35). CONCLUSION: Second-opinion interpretations of neuroimaging studies by subspecialized oncologic neuroradiologists provide added value by reducing error and optimizing the care of cancer patients. Cancer 2016. © 2016 American Cancer Society. Cancer 2016;122:2708-2714. © 2016 American Cancer Society.


Asunto(s)
Errores Diagnósticos/prevención & control , Interpretación de Imagen Asistida por Computador/normas , Neoplasias/diagnóstico por imagen , Neuroimagen/normas , Atención al Paciente/normas , Derivación y Consulta , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Lactante , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Neoplasias/patología , Neoplasias/terapia , Variaciones Dependientes del Observador , Médicos , Pronóstico , Radiólogos , Estudios Retrospectivos , Tomografía Computarizada por Rayos X , Adulto Joven
18.
Magn Reson Med ; 75(4): 1708-16, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25995019

RESUMEN

PURPOSE: Ultrasound-guided fine needle aspirate cytology fails to diagnose many malignant thyroid nodules; consequently, patients may undergo diagnostic lobectomy. This study assessed whether textural analysis (TA) could noninvasively stratify thyroid nodules accurately using diffusion-weighted MRI (DW-MRI). METHODS: This multi-institutional study examined 3T DW-MRI images obtained with spin echo echo planar imaging sequences. The training data set included 26 patients from Cambridge, United Kingdom, and the test data set included 18 thyroid cancer patients from Memorial Sloan Kettering Cancer Center (New York, New York, USA). Apparent diffusion coefficients (ADCs) were compared over regions of interest (ROIs) defined on thyroid nodules. TA, linear discriminant analysis (LDA), and feature reduction were performed using the 21 MaZda-generated texture parameters that best distinguished benign and malignant ROIs. RESULTS: Training data set mean ADC values were significantly different for benign and malignant nodules (P = 0.02) with a sensitivity and specificity of 70% and 63%, respectively, and a receiver operator characteristic (ROC) area under the curve (AUC) of 0.73. The LDA model of the top 21 textural features correctly classified 89/94 DW-MRI ROIs with 92% sensitivity, 96% specificity, and an AUC of 0.97. This algorithm correctly classified 16/18 (89%) patients in the independently obtained test set of thyroid DW-MRI scans. CONCLUSION: TA classifies thyroid nodules with high sensitivity and specificity on multi-institutional DW-MRI data sets. This method requires further validation in a larger prospective study. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance.


Asunto(s)
Imagen de Difusión por Resonancia Magnética/métodos , Interpretación de Imagen Asistida por Computador/métodos , Glándula Tiroides/diagnóstico por imagen , Neoplasias de la Tiroides/diagnóstico por imagen , Adulto , Anciano , Área Bajo la Curva , Estudios de Cohortes , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados
19.
J Magn Reson Imaging ; 44(3): 521-40, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26892827

RESUMEN

The significant advances in magnetic resonance imaging (MRI) hardware and software, sequence design, and postprocessing methods have made diffusion-weighted imaging (DWI) an important part of body MRI protocols and have fueled extensive research on quantitative diffusion outside the brain, particularly in the oncologic setting. In this review, we summarize the most up-to-date information on DWI acquisition and clinical applications outside the brain, as discussed in an ISMRM-sponsored symposium held in April 2015. We first introduce recent advances in acquisition, processing, and quality control; then review scientific evidence in major organ systems; and finally describe future directions. J. Magn. Reson. Imaging 2016;44:521-540.


Asunto(s)
Algoritmos , Imagen de Difusión por Resonancia Magnética/normas , Aumento de la Imagen/normas , Interpretación de Imagen Asistida por Computador/normas , Guías de Práctica Clínica como Asunto , Radiología/normas , Encéfalo/anatomía & histología , Encéfalo/diagnóstico por imagen , Humanos , Aumento de la Imagen/métodos , Imagenología Tridimensional/normas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
20.
J Comput Assist Tomogr ; 39(3): 334-9, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25700226

RESUMEN

OBJECTIVE: To investigate the repeatability of the quantitative magnetic resonance imaging (MRI) metric (apparent diffusion coefficient [ADC]) derived from reduced field-of-view diffusion-weighted (rFOV DWI) on thyroid glands in a clinical setting. MATERIALS AND METHODS: Ten healthy human volunteers were enrolled in MRI studies performed on a 3-T MRI scanner. Each volunteer was designed to undergo 3 longitudinal examinations (2 weeks apart) with 2 repetitive sessions within each examination, which included rFOV and conventional full field-of-view (fFOV) DWI scans. Diffusion-weighted images were assessed and scored based on image characteristics. Apparent diffusion coefficient values of thyroid glands from all participants were calculated based on regions of interest. Repeatability analysis was performed based on the framework proposed by the Quantitative Imaging Biomarker Alliance, generating 4 repeatability metrics: within-participant variance ((Equation is included in full-text article.)), repeatability coefficients, intraclass correlation coefficient, and within-participant coefficient of variation. Student t test was used to compare the performance difference between rFOV and fFOV DWI. RESULTS: The overall image quality from rFOV DWI was significantly higher than that from fFOV DWI (P = 0.04). The ADC values calculated from rFOV DWI were significantly lower than corresponding values from fFOV DWI (P < 0.001). There was no significant difference in ADC values across sessions and examinations in either rFOV or fFOV DWI (P > 0.05). Reduced field-of-view DWI had lower values of (Equation is included in full-text article.), repeatability coefficient, and within-participant coefficient of variation and had a higher value of intraclass correlation coefficient compared with fFOV DWI across either sessions or examinations. CONCLUSIONS: This study demonstrated that rFOV DWI produced more superior-quality DWI images and more repeatable ADC measurements compared with fFOV DWI, thus providing a feasible quantitative imaging tool for investigating thyroid glands in clinical settings.


Asunto(s)
Algoritmos , Imagen de Difusión por Resonancia Magnética/métodos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Glándula Tiroides/anatomía & histología , Adulto , Humanos , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA