Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 85
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Vasc Surg ; 79(2): 198-206.e15, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37967588

RESUMEN

OBJECTIVE: We assessed the suitability of two triple branch arch devices (aBranch) (Terumo aortic and Cook Medical) and a balloon-expandable covered stent (VBX, W. L. Gore & Associates, Johnson & Johnson) to incorporate the brachiocephalic trunk (BCT) in a cohort previously treated with hybrid thoracic endovascular repair (TEVAR). METHODS: This is a single-center, retrospective, all-comers, preclinical suitability study. We conducted an analysis of preoperative computed tomography scans in surgical patients between 1999 and 2022 in a single vascular surgery unit. The primary outcome was the aortic suitability of aBranch devices and VBX as mating stent for BCT in previous hybrid TEVAR. Hybrid repair of the aortic arch included TEVAR, fenestrated or branched TEVAR associated with any surgical debranching of the supra-aortic trunks and chimney TEVAR with proximal landing in zones 0 to 2. Secondary outcomes included (i) suitability assessment when excluding minor instruction for use (IFU) criteria, (ii) a comparison of suitable and nonsuitable patients, (iii) risk factors analysis for nonsuitability, and (iv) a description of the exclusion causes. RESULTS: During the study period, 120 patients were treated. Among elective patients (n = 73), the suitability of any aBranch was 82.2% (60/73) and VBX was suitable in 64.4% of BCTs (47/73). The aBranch suitable patients had a significantly longer sinotubular-BCT length (P = .017) and smaller distal ascending aorta (P = .043) as compared with nonsuitable ones. The suitability of Terumo Aortic and Cook Medical devices was 52.1% (38/73) and 46.6% (34/73), respectively. When minor IFU criteria were ignored, suitability increased to 82.2% (60/73) and 63.0% (46/73), respectively. Left common carotid artery diameter and sinotubular-BCT length were significant nonsuitability risk factors for Terumo Aortic aBranch in multivariable analysis. No associations were found for Cook Medical device. The outcomes were tested in the entire cohort demonstrating a global suitability of 82.9%, increasing to 86.3% when ignoring minor IFUs. VBX was anatomically suitable to use in BCT in 73.2% of patient BCTs. CONCLUSIONS: aBranch devices are anatomically suitable in a vast majority of patients (86%) undergoing hybrid TEVAR. The innominate artery seems eligible for incorporation with VBX in almost two-thirds of patients. This mating stent may help to overcome some minor IFU restrictions.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Reparación Endovascular de Aneurismas , Implantación de Prótesis Vascular/efectos adversos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/etiología , Estudios Retrospectivos , Procedimientos Endovasculares/efectos adversos , Diseño de Prótesis , Stents , Resultado del Tratamiento
2.
J Vasc Surg ; 79(5): 1026-1033, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38154606

RESUMEN

BACKGROUND: Endovascular treatment of thoracoabdominal aortic aneurysms has become common, with satisfactory results. Nevertheless, long-term durability remains an issue mainly because of target visceral vessel (TVV) instability. Currently, no covered stent has been approved as a bridging stent graft (BSG), demanding continuous research on this topic. METHODS: This was a multicenter observational retrospective cohort study comparing the midterm results of the Bard Covera Plus and Gore VBX as BSGs during branched endovascular aneurysm repair. The primary outcome was the comparison of the target vessel instability between the two groups. Primary patency, freedom from branch-related type I and III endoleaks and reintervention, and technical and clinical success were considered secondary outcomes. Logistic regression analysis was used to assess the association between selected baseline factors and TVV instability. TVV instability during follow-up was then evaluated using the Kaplan-Meier cumulative function. RESULTS: Three hundred forty-five TVVs in 106 patients were considered suitable for the analysis. Two hundred twenty vessels were stented with the Covera stent graft (64%) and 125 with VBX (36%). Two hundred ninety-nine TVVs received a single BSG, 45 two BSGs, and only 1 three BSGs. Bare metal stent relining was required in 36% of TVVs, mostly in the Covera group (89 [41%] vs 36 [29%]) (P = .030). The primary technical success rate was 96% (331/345), and the assisted primary technical success rate was 99% (342/345). The TVV instability rate within 30 days was 2% (one Covera and five VBX; P = .015). Three BSG occlusions (one Covera and two VBX) and three type Ic endoleaks (three VBX) were detected. The median follow-up was 13.9 months (range, 5.8-25.5 months). Sixteen TVV instabilities were detected during the follow-up. Twelve BSG occlusions (six Covera and six VBX), three type Ic endoleaks (one Covera and two VBX), and one type IIIc endoleak (VBX). The overall target vessel instability rate was 5% (16/342). TVV instability was associated with the use of Gore VBX in the univariable logistic regression (odds ratio, 3.0; 95% confidence interval, 1.1-8.0; P = .027). Aneurysm rupture and aneurysm diameter were also associated with TVV instability in the univariable analysis (P = .002 and P = .008, respectively). The only factor predisposing to TVV instability in the multivariable logistic regression analysis was the use of Gore VBX as a BSG (odds ratio, 2.9; 95% confidence interval, 1.0-8.0; P = .043). Kaplan-Meier analysis showed a significantly higher risk of TVV instability in the VBX group (P < .001). CONCLUSIONS: Overall midterm outcomes in this cohort were satisfactory. Patency rates were similar between the two stents. Nevertheless, VBX seems to be associated with worse TVV instability. These results may be correlated with a higher incidence of type Ic endoleaks, which require an extensive learning curve for correct stent selection and deployment.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Prótesis Vascular/efectos adversos , Reparación Endovascular de Aneurismas , Implantación de Prótesis Vascular/efectos adversos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Endofuga/etiología , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Estudios Retrospectivos , Resultado del Tratamiento , Factores de Riesgo , Procedimientos Endovasculares/efectos adversos , Diseño de Prótesis , Stents/efectos adversos
3.
J Vasc Surg ; 80(2): 586-594.e5, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38636609

RESUMEN

OBJECTIVE: This study aimed to investigate the incidence of cerebrospinal fluid drainage (CSFD)-related complications specifically in patients who underwent fenestrated and branched endovascular aortic repair (F/B-EVAR). This objective was chosen considering the limitations and uncertainties surrounding its efficacy in preventing spinal cord injury. METHODS: A systematic review following Cochrane Handbook and Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines was conducted (PROSPERO; #CRD42022359223). Literature searches of MEDLINE, Embase, and Scopus were performed until May 1, 2023, focusing on studies published after January 1, 2000. The inclusion criteria encompassed studies reporting on F/B-EVAR, CSFD, and drain-related complications. Data extraction and quality assessment using the Newcastle-Ottawa Scale were performed by multiple reviewers to ensure accuracy and reliability. A proportion meta-analysis was conducted to calculate the pooled rate and 95% confidence interval (CI). The primary and secondary outcomes were CSFD-related mortality and morbidity, respectively. RESULTS: Six retrospective, observational, single-center studies were included, totaling 1079 patients and 730 CSFD placements (all prophylactic except for one). The Newcastle-Ottawa Scale showed a high to moderate risk of bias. The analysis revealed a CSFD-related mortality rate of 1.4% (95% CI: 0.0-4.8; I2 = 67.7%) and an overall morbidity rate of 25.6% (95% CI: 13.6-39.7; I2 = 83.2%). The overall major, moderate, and minor estimated complication rates were 6.1% (95% CI: 4.1-8.5; I2 = 0%), 4.6% (95% CI: 2.4-7.3; I2 = 33.5%), and 26.4% (95% CI: 16.5-37.7; I2 = 84.9%), respectively. Severe complications included intracranial hemorrhage (2.8%), spinal hematoma (1.4%), subarachnoid hemorrhage (1.4%), and CSFD-related neurological deficits (1.1%). A pooled estimate of 11.4% for nonfunctioning drainage was found. CONCLUSIONS: F/B-EVAR patients showed a notable incidence of CSFD-related death and substantial morbidity. This study highlights the limitations of the available data, the high prevalence of complications associated with CSFD, and the need for further research to better understand the risks and benefits of CSFD in F/B-EVAR. This calls for careful consideration regarding the routine use of prophylactic drainage due to the accumulating evidence of the risks associated with CSFD without proven benefit in this specific context.


Asunto(s)
Implantación de Prótesis Vascular , Drenaje , Procedimientos Endovasculares , Humanos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Drenaje/efectos adversos , Drenaje/mortalidad , Drenaje/instrumentación , Factores de Riesgo , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Resultado del Tratamiento , Medición de Riesgo , Femenino , Masculino , Anciano , Complicaciones Posoperatorias/prevención & control , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/epidemiología , Reparación Endovascular de Aneurismas
4.
J Vasc Surg ; 79(5): 997-1004.e1, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38142945

RESUMEN

OBJECTIVE: We compared the outcomes of patients treated with nonbare stents (NBS) and proximal bare stents (PBS) endografts with a proximal landing zone in the aortic arch during thoracic endovascular aortic repair (TEVAR). METHODS: We conducted a retrospective cohort, observational, multicenter study that included 361 consecutive TEVAR procedures undertaken between November 2005 and December 2021. TEVAR patients with both BS and NBS Relay stent graft configurations with proximal landing in zones 1, 2, or 3 were enrolled. Preoperative anamnestic and morphological data, clinical outcomes, and aortic modifications 30 days after surgery and at the latest follow-up available were collected. The primary outcome was freedom from proximal endoleak (type IA) comparing the two configurations. Total and detailed endoleak rates, clinical and technical success, intraoperative additional maneuvers, major adverse events, and reinterventions were secondary outcomes. RESULTS: The median follow-up was 4.9 (interquartile range, 2.0-8.1) years. No statistically significant difference between NBS and PBS patients concerning 30-day major adverse events, retrograde aortic dissection, disabling stroke, or late type IA endoleak (10.8% vs 7.8%; P = .597). Aneurysmal disease (P = .026), PLZ diameter of >34 mm (P = .026), aortic tortuosity index of >1.4 (P = .008), type III aortic arch (P = .068), and PLZ thrombus (P = .014) identified as risk factors by univariate Cox regression analysis. PLZ thrombus was the only type IA endoleak risk factor at multivariate Cox regression (P = .016). CONCLUSIONS: We found no statistically significant difference in freedom from type IA endoleak, retrograde dissection, or disabling stroke observed between the NBS and the BS configuration of the Relay endograft. Proximal landing zone thrombotic apposition was a prominent risk factor for type IA endoleak after TEVAR.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Accidente Cerebrovascular , Trombosis , Humanos , Aorta Torácica/cirugía , Aorta Torácica/trasplante , Reparación Endovascular de Aneurismas , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Endofuga/diagnóstico por imagen , Endofuga/etiología , Endofuga/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Estudios Retrospectivos , Aneurisma de la Aorta Abdominal/cirugía , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Diseño de Prótesis , Factores de Tiempo , Stents/efectos adversos , Accidente Cerebrovascular/etiología , Trombosis/etiología
5.
J Endovasc Ther ; : 15266028241255541, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38778640

RESUMEN

PURPOSE: To evaluate the influence of endograft fixation type on the incidence, treatment, and outcomes of type III endoleaks (TIIIELs). MATERIALS AND METHODS: Abdominal aortic aneurysms (AAAs) treated with bifurcated endografts between 1994 and 2020 were prospectively collected and reviewed. The endograft included were classified as "Anatomical Fixation" (AF) (Powerlink [Endologix] and AFX [Endologix]) or "Proximal Fixation" (PF). The primary outcome was the incidence of TIIIEL over time, stratified by fixation type. Secondary outcomes included between-group comparisons of baseline characteristics, intraoperative details during TIIIEL correction, and survival analysis after TIIIEL diagnosis. RESULTS: A total of 2065 endovascular aneurysm repairs were performed: 872 (42.2%) with AF and 1193 (57.8%) with PF devices. The estimated incidence of TIIIEL at 1, 5, and 10 years was 0.4%, 4.2%, and 7.3%, and 0.5%, 3.2%, and 4.6% for AF and PF, respectively (p=0.157), and fixation type was not associated with TIIIEL development in the competing risk regression model (p=0.101). The cumulative overall survival rate in patients diagnosed with TIIIEL did not differ significantly between the groups (p=0.077). The rate of recurrent TIIIELs was significantly lower in the AF group (7.1% vs 22.7%; p=0.044); however, no significant difference was found in secondary reintervention between the two groups (11.9% vs 27.3%, p=0.074). Patients with angulated and calcified aortic neck (SHR 3.4, 95% CI 1.2-9.6, p=0.022) and larger aneurysms (SHR 1.2; 95% CI 1.1-1.3; p<0.001) had a higher risk of TIIIEL. Likewise, the use of three or more endograft components increased the risk of TIIIEL by 3.1 times (SHR 3.1; 95% CI 1.7-5.4; p<0.001). CONCLUSIONS: The occurrence of TIIIELs was not affected by the type of endograft fixation. For larger abdominal aortic aneurysms (AAAs) and aneurysms with angulated and calcified aortic necks, there is a higher likelihood of developing TIIIELs during follow-up, regardless of the endograft type used. CLINICAL IMPACT: The type of fixation does not influence the incidence of TIII ELs. EVAR in larger AAAs and aneurysms with angulated and calcified aortic necks have a higher risk of developing TIII EL. Moreover, the risk of TIII EL is considerably increased by the use of three or more modular components.

6.
J Endovasc Ther ; : 15266028241284364, 2024 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-39369322

RESUMEN

INTRODUCTION: To confirm real-world clinical practice results reported with anatomically fixed bifurcated endograft, a physician-initiated study was designed-AFX2-LIVE registry. MATERIALS AND METHODS: From November 2019 to August 2021, investigators enrolled all consecutive patients treated with AFX2 (Endologix Inc., Irvine, CA, USA) endograft. Patients with abdominal aortic aneurysms (AAAs), penetrating aortic ulcers (PAU), and isolated infrarenal aortic dissections were included. Clinical and anatomical data, including baseline, intraoperative, and in-hospital details, as well as follow-up data, were collected in an anonymized prospectively compiled database. The primary endpoint of this study was to evaluate the technical and clinical success of endovascular aortic repair (EVAR) using AFX2 endograft. RESULTS: A total of 535 patients were enrolled from 43 Italian and Spanish centers and analyzed according to the protocol. Four hundred eighty-nine patients were male (91.4%), with a mean age of 75±8.92 years (range 52-94). Four hundred sixty-six patients (87.1%) were treated for AAA, 49 (9.3%) for PAU, and 20 (3.6%) for isolated abdominal aortic dissection. A proximal extension was needed in 48% of the cases. Assisted technical success was achieved in all but one patient (99.8%). At 30 days follow-up, no AAA-related deaths were recorded, and nine patients (1.6%) required reintervention. At a mean follow-up period of 15.22±13.65 (range 1-53) months, data were available for 479 patients (89.5%). Clinical success was achieved in 98.2% (95% confidence interval [CI]: 96.4-99.1) at 3 months, 93.9% (95% CI: 90.1-96.1) at 1 year, and 74.1% (95% CI: 62.8-82.4) at 4 years follow-up. The estimated freedom from all-cause mortality was 97.7%, 93.4%, 81.6%, 77.5%, and 70.9%, and freedom from AAA-related mortality was 100%, 99.6%, 99.6%, 99.6%, and 97.3% at 3, 12, 24, 36, and 48 months, respectively. Twenty reinterventions (3.7%) were required in 19 patients, of which 3 late open conversions (0.6%) were performed, and 2 AAA-related deaths were observed. CONCLUSION: This study demonstrated excellent clinical and technical success rates of EVAR with anatomically fixed endografts, providing valuable insights into real-world clinical outcomes. CLINICAL IMPACT: The AFX2-LIVE study could have a significant impact by providing robust evidence supporting the effectiveness and safety of EVAR using bifurcated endografts with anatomical fixation in real-world clinical practice, ultimately leading to improved outcomes and enhanced patient care in the management of abdominal aortic pathologies.

7.
Ann Vasc Surg ; 108: 157-165, 2024 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38944191

RESUMEN

BACKGROUND: To describe the outcomes of aortic endograft thrombosis (AET) as an indication for open conversion (OC) after endovascular aortic aneurysm repair (EVAR) in a multicenter experience. METHODS: This study retrospectively analyzed cases of OC for AET following EVAR across 12 Italian Vascular Surgery centers from 1997 to September 2022. The end points were as follows: 30-day mortality and major postoperative complications. Follow-up data included survival and aortic-related complications. RESULTS: Sixteen patients (mean age: 68.6 ± 8.5 years) were included. The median elapsed time between EVAR and OC was 26.46 months (interquartile range: 13.8-45.9). Proximal aortic cross-clamping site was supraceliac in 8 out of 16 (50%) patients, and complete removal of the stentgraft was achieved in 75% of cases (12/16 patients). Reconstructions were aorto-bi-iliac grafts in 8 cases (50%), 7 aortobifemoral bypass grafts (43.8%), and 1 aortoaortic tube graft (6.3%). All patients were symptomatic at presentation (68.7% unilateral acute limb ischemia, 25% bilateral acute limb ischemia, 1 patient had chronic severe claudication). Thirty-day mortality was 12.5% (2/16 patients). The overall morbidity rate was 43.8% (7 of 16 patients). No specific risk factors for early mortality were found. The overall estimated survival rate was 80.4% at 1 year, 62.5% at 2 years, and 41.7% at 3 years. CONCLUSIONS: OC for AET is typically reserved for complex cases that are not amenable to endovascular solutions. The frequent need for suprarenal clamping and complete endograft removal seems to be associated with high short-term mortality.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Conversión a Cirugía Abierta , Procedimientos Endovasculares , Trombosis , Humanos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Anciano , Masculino , Estudios Retrospectivos , Femenino , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Factores de Tiempo , Resultado del Tratamiento , Italia , Factores de Riesgo , Persona de Mediana Edad , Trombosis/etiología , Trombosis/cirugía , Trombosis/mortalidad , Conversión a Cirugía Abierta/efectos adversos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Oclusión de Injerto Vascular/etiología , Oclusión de Injerto Vascular/cirugía , Stents , Remoción de Dispositivos/efectos adversos , Anciano de 80 o más Años , Reparación Endovascular de Aneurismas
8.
J Vasc Surg ; 77(3): 811-817.e2, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36243263

RESUMEN

OBJECTIVE: The objective of this study was to assess the primary endpoint defined as the detection of micro-embolic signals (MES) by the use of transcranial Doppler (TCD) in patients with asymptomatic carotid stenosis (≥70%) scheduled for carotid endarterectomy. The secondary endpoint consisted of testing the association of MES with stenosis severity, histopathological, and ultrasound characteristics. METHODS: This was a single-center, single-arm, prospective, observational trial. Computed tomography angiography and ultrasound assessment (Geroulakos classification) were mandatory as well as being under best medical therapy. MES number and characteristics were investigated in Holter mode TCD-X device with a standard 1.5 MHz probe. The time points of evaluation were: 24 hours preoperative, 24 hours postoperative, and 30 days postoperative. The histopathological analysis was performed according to the modified American Heart Association classification. One-way analysis of variance tested MES differences over time. Univariable and multivariable logistic regression tested variables potentially associated with MES. RESULTS: A total of 120 patients demonstrated a significant reduction of the mean number of MES (3.35 ± 10.04 and 0.82 ± 2.39; pre- and post-carotid endarterectomy, respectively), becoming undetectable at 30 days (P = .001). Hypoechogenic plaques assessed by ultrasound were a significant risk factor for MES (P = .001). The features of plaque vulnerability, such as hemorrhagic component (P = .011), neovascularization (P = .025), signs of inflammation (P = .027), and rupture of the fibrous cap (P = .002) were predictors of MES. Cap rupture was the only predictor in the multivariate analysis (odds ratio, 5.98; P = .030). The stenosis severity was not associated with MES (P = .95) CONCLUSIONS: Patients under best medical therapy had a preoperative embolic activity becoming no more detectable after surgery. Both ultrasound and histologic markers of vulnerability were predictors of MES, and stenosis severity was not associated. TCD gives better insight into the real embolic risk, and future studies should evaluate clinical results coming from its implementation with standard imaging techniques. CLINICALTRIAL: gov registration number NCT05134493.


Asunto(s)
Estenosis Carotídea , Endarterectomía Carotidea , Embolia Intracraneal , Placa Aterosclerótica , Humanos , Estenosis Carotídea/cirugía , Constricción Patológica/complicaciones , Estudios Prospectivos , Ultrasonografía Doppler Transcraneal/métodos , Endarterectomía Carotidea/efectos adversos , Placa Aterosclerótica/complicaciones , Embolia Intracraneal/etiología
9.
J Vasc Surg ; 77(5): 1330-1338.e2, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36621617

RESUMEN

BACKGROUND: Arch pathology represents one of the last frontiers in aortic aneurysm endovascular management. Several companies recently developed dedicated branched and fenestrated endografts specifically designed for the aortic arch, aiming to overcome some of the issues associated with standard thoracic endograft and supra-aortic vessels extra-anatomic debranching. This study aimed to evaluate early outcomes obtained with a custom-made fenestrated endograft approved for thoracic aortic aneurysms exclusion. METHODS: All consecutive patients treated with the Najuta endograft (Kawasumi Laboratories, Inc, Tokyo, Japan) in Italy were enrolled prospectively and included in the study population. Anatomic characteristics and perioperative data were analyzed retrospectively. Study end points were technical success, 30-day clinical success, overall survival, supra-aortic vessel patency, endoleak, and need for reintervention or surgical conversion. RESULTS: Between 2018 and 2022, 76 patients received a Najuta endograft in Italy and were enrolled in the study. The median patient age was 72 years (interquartile range, 69-76 years) and 80.3% were male. Most of the patients received treatment for atherosclerotic aneurysms (80.3%); others were treated for postdissection aneurysms (7.9%), penetrating aortic ulcer (9.2%), or type I endoleak correction after previous thoracic endovascular repair (2.6%). Overall, 161 supra-aortic vessels were preserved through a dedicated fenestration. Technical success was achieved in 74 of 76 procedure (97.4%); both failures were associated with endoleak detection at final angiography (one type I and one type III endoleak). Two distal migrations occurred during the implanting procedure. Clinical success at 30 days was 94.7%. Two early reinterventions were needed within 30 days after index procedure: in one case, an aortic false lumen coils embolization was performed, because distal re-entry caused enlargement of the postdissection thoracic aneurysm. The other procedure consisted of a femoral pseudoaneurysm repair. The median follow-up was 7 months (interquartile range, 3-15 months); no supra-aortic vessel occlusions occurred and no patients needed surgical conversion. CONCLUSIONS: Early results suggest that, in selected patients with aortic arch pathology needing a proximal landing, an endovascular approach with the Najuta system is safe and effective, especially for those at high surgical risk. A strict follow-up with high-quality computed tomography angiography images and eventual evaluation for long-term complications is needed to confirm these initial experience findings.


Asunto(s)
Aneurisma de la Aorta Torácica , Aneurisma de la Aorta , Enfermedades de la Aorta , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Anciano , Femenino , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Endofuga/etiología , Endofuga/complicaciones , Estudios Retrospectivos , Factores de Riesgo , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Resultado del Tratamiento , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/complicaciones , Aneurisma de la Aorta/cirugía , Procedimientos Endovasculares/efectos adversos , Enfermedades de la Aorta/cirugía , Diseño de Prótesis
10.
J Vasc Surg ; 78(2): 540-547.e4, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36754248

RESUMEN

OBJECTIVE: To investigate the long-term reinterventions of thoracic endovascular repair (TEVAR) after blunt traumatic aortic injury. METHODS: MEDLINE, EMBASE, and Cochrane databases were interrogated until June 2021. Inclusion criteria were blunt traumatic aortic injury treated with TEVAR and mean follow-up of more than 60 months. A systematic review was conducted and data were pooled using a random effects model of proportions applying the Freeman-Tukey transformation. Late reintervention was the primary outcome. Secondary outcomes were procedure-related complications (endoleak, in-stent thrombosis, occlusion, infolding/collapse, bird-beak, migration, and left arm claudication), overall and aortic-related mortality, and aortic diameter changes. RESULTS: Eleven studies with a low quality assessment were included. Four hundred eight patients were collected and the 389 surviving more than 30 days were included. The mean follow-up was 8.2 years (95% confidence interval [CI], 5.7-10.8; I2 = 40.2%). Late reintervention was 2.1% (95% CI, 0.6-3.9; I2 = 0.0%; 11/389 cases) with 0.1% (95% CI, 0.0-1.2; I2 = 0.0%; 3/389) occurring after 5 years. Bird-beak was identified in 38.7% (95% CI, 16.4-63.6; I2 = 86.6%). Left arm claudication occurring after 30 days was 3.1% (95% CI, 0.1-8.6; I2 = 26.9%; 11/140 cases). In-stent thrombosis was 1.9% (95% CI, 0.1-5.2; I2 = 51.8%; 11/389 cases). Endoleak was 0.5% (95% CI, 0.0-1.9; I2 = 0.0%; 5/389 cases). Infolding, occlusion, and migration were reported in 2 of 389, 1 of 389, and 0 of 389 patients, respectively. Overall late survival was 95.6% (95% CI, 88.1-99.8; I2 = 84.7%; 358/389 patients) and only one patient accounted for aortic related mortality. The increase in proximal and distal aortic diameters was estimated at 2.7 mm (95% CI, 1.2-4.3; I2 = 0.0%) and 2.5 mm (95% CI, 1.1-3.9; I2 = 0.0%), respectively. CONCLUSIONS: TEVAR demonstrates remarkably good long-term results and reinterventions are rarely required. Aortic reinterventions tend to occur within the first and after the fifth year.


Asunto(s)
Implantación de Prótesis Vascular , Procedimientos Endovasculares , Heridas no Penetrantes , Humanos , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/efectos adversos , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/cirugía , Aorta Torácica/lesiones , Stents/efectos adversos , Endofuga/etiología , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Estudios Retrospectivos , Heridas no Penetrantes/diagnóstico por imagen , Heridas no Penetrantes/cirugía , Heridas no Penetrantes/complicaciones
11.
J Vasc Surg ; 77(3): 677-684, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36332806

RESUMEN

BACKGROUND: Mid-term durability of branches has already been established, and BF-branched and fenestrated endovascular repair has shown comparable results with open repair in the treatment of thoracoabdominal aortic aneurysms (TAAAs). Nevertheless, target vessel instability remains the most frequent adverse event after complex endovascular aortic repair. Type III endoleaks from directional branches have been reported with a low incidence, but risk factors for this complication have not been investigated yet. METHODS: This was a dual-center observational retrospective cohort study. Data were collected prospectively for each patient treated with branched endovascular repair between April 2008 and December 2019. The primary outcome was to assess potential risk factors for branch disconnection and fracture. A logistic regression analysis was performed, including preoperative and postoperative measurements as well as intraoperative details. A Cox regression hazard analysis was performed to evaluate the influence of preoperative aneurysm diameter and target vessel angulation on the outcome during follow-up. RESULTS: Two hundred ninety-five target visceral vessels (TVVs) in 91 patients were considered suitable for cannulation. Technical success was 96.9% (286/295 TVVs). The median follow-up was 32.5 months (interquartile range, 14.2-50.1 months). Twelve type III endoleaks from directional branches were detected (4.2%; 5 bridging stent graft fractures and 7 disconnections). Five type III endoleaks involved the celiac trunk (one fracture and four disconnections), five the superior mesenteric artery (four fractures and one disconnection), and two the renal arteries (both disconnections). The median time to type III endoleak was 22.2 months (interquartile range, 10.9-37.6 months). Preoperative TAAA diameter (P = .028), preoperative TVV angulation (P = .037), the use of a BeGraft stent graft as bridging stent graft (P = .001), and different stent types on the same vessel (P = .048) were associated with type III endoleak at univariable analysis. Using a BeGraft stent graft (P = .010) was the only significant factor predisposing to type III endoleak at multiple logistic regression. The Cox regression analysis showed a two-fold increased risk for type III endoleak for every 10-mm increase in preoperative TAAA diameter (hazard ratio, 2.00; 95% confidence interval, 1.08-3.72; P = .028) and a 1.5 increased risk every 12° increase of preoperative TVV angulation (hazard ratio, 1.47; 95% confidence interval, 1.02-2.10; P = .037). CONCLUSIONS: Type III endoleaks from directional branches are a non-negligible complication after branched endovascular repair, with a relevant incidence. They tended to be clustered on specific patients, and aneurysm diameter and TVV angulation are strictly associated with the outcome. Different stent types on the same vessel should be avoided whenever possible. An intensified follow-up should be adopted for patients with large aneurysms, implanted with first-generation BeGraft, or who have been already diagnosed with type III endoleaks.


Asunto(s)
Aneurisma de la Aorta Abdominal , Aneurisma de la Aorta Torácica , Aneurisma de la Aorta Toracoabdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Endofuga/etiología , Prótesis Vascular , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Procedimientos Endovasculares/efectos adversos , Factores de Riesgo , Diseño de Prótesis
12.
J Vasc Surg ; 77(6): 1598-1606.e3, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36822256

RESUMEN

OBJECTIVE: To investigate the technical periprocedural and midterm outcomes of endovascular repairs with multibranched endovascular repair or iliac branch devices combined with a new self-expanding covered stent. METHODS: The COvera in BRAnch registry is a physician-initiated, multicenter, ambispective, observational registry (ClinicalTrials.gov Identifier: NCT04598802) enrolling patients receiving a multibranched endovascular repair or iliac branch devices procedure mated with Bard Covera Plus (Tempe, AZ) covered stent, designed to evaluate the outcomes of the covered stent mated with patient-specific and off-the-shelf branched stent graft. Primary end points were technical success, branch instability, and freedom from aortic and branch-related reintervention within 30 days and at follow-up. Preoperative characteristics, comorbidities, and outcomes definitions were graded according to the Society for Vascular Surgery reporting standards. RESULTS: Two hundred eighty-four patients (76 years; range, 70-80 years; 79% males) in 24 centers were enrolled for a total of 708 target vessels treated. The covered stents were mated with an off-the-shelf graft in 556 vessels (79%) and a custom-made graft in 152 (21%). Three hundred seven adjunctive relining stents in 277 vessels (39%) were deployed, of which 116 (38%) were proximal, 66 (21%) intrastent, and 125 (41%) distal. Adjunctive relining stent placement was more frequent when landing in a vessel branch instead of the main trunk (59% vs 39%; P = .031), performing a percutaneous access (49% vs 35%; P < .001), using a stent with a diameter of 8 mm or greater (44% vs 36%; P = .032) and a length of 80 mm or greater (65% vs 55%; P = .005), when a post-dilatation was not performed (45% vs 29%; P < .001) and when an inner branch configuration was used (55% vs 35%; P < .001). Perioperative technical bridging success was 98%. Eight patients (3%) died in the perioperative period. Two deaths (1%) were associated with renal branch occlusion followed by acute kidney injury and paraplegia. Follow-up data were available for 638 vessels (90%) at a median of 32 months (Q1, Q3, 21, 46). Branch instability was reported in 1% of branches. Forty-six patients (17%) died during follow-up, nine (3%) of them owing to aortic-related causes. Primary patency rates at 1, 2, and 3 years were 99% (581/587), 99% (404/411), and 97% (272/279), respectively. Branch instability was associated with patient-specific devices (9% vs 4%; P = .014) and intrastent adjunctive stent placement (12% vs 2%; P = .003), especially when a bare metal balloon-expandable stent was used (25% vs 3%; P < .001). CONCLUSIONS: The use of this new self-expanding covered stent mated with branched endografts proved to be safe and feasible with high technical procedural success rates. Low rates of branch instability were observed at midterm follow-up. Comparative studies with other commercially available covered stents are warranted.


Asunto(s)
Aneurisma de la Aorta Torácica , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Masculino , Humanos , Femenino , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Aneurisma de la Aorta Torácica/cirugía , Factores de Riesgo , Grado de Desobstrucción Vascular , Diseño de Prótesis , Resultado del Tratamiento , Stents , Italia , Procedimientos Endovasculares/efectos adversos , Sistema de Registros
13.
J Vasc Surg ; 78(5): 1270-1277, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37532160

RESUMEN

OBJECTIVE: The aim of the study was to compare the early and medium-term outcomes of bypass vs endovascular treatment of occluded femoro-popliteal stents in patients with chronic limb-threatening ischemia (the OUT-STEPP multicentric registry). METHODS: Between January 2016 and December 2021, 317 patients in 14 centers underwent treatment for a symptomatic occlusion of femoro-popliteal stent/stents. One hundred sixty-one patients were included into the present study: 46 (28.6%) underwent open bypass surgery (Group OPEN), and 115 (71.4%) underwent endovascular revascularization (Group ENDO). Early (30 days) results were assessed and compared between the two groups. Estimated 5-year outcomes were evaluated and compared with the log rank test. RESULTS: At 30 days, no differences were found in terms of major adverse cardiovascular events, acute kidney injury, reinterventions, major amputation, and all-cause mortality between the two groups. The need for blood transfusions was higher for patients in Group OPEN (17; 36.9% vs 13; 11.3%; P < .001). The mean length of intensive care unit stay and the mean hospital stay were higher for patients in Group OPEN ([0.3 ± 0.9 vs 0 days; P < .001] and [9.7 ± 5.8 vs 3.3 ± 1.4 days; P < .001], respectively). The overall median duration of follow-up was 33.1 months (interquartile range, 14-49.5 months). At 5 years, there were no differences between the two groups in terms of survival (68.7% Group OPEN vs 68.8% Group ENDO; P = .27; log-rank, 1.21), primary patency (56.3% Group OPEN vs 67.8% Group ENDO; P = .39; log-rank, 0.75), secondary patency (59.1% Group OPEN vs 77.8% Group ENDO; P = .24; log-rank, 1.40), absence of target lesion restenosis (56.8% Group OPEN vs 62.7% Group ENDO; P = .42; log-rank, 0.65), and limb salvage (77.2% Group OPEN vs 90.4% Group ENDO; P = .17; log-rank, 1.87). CONCLUSIONS: Both bypass and endovascular treatment provided safe and effective restoration of patency for femoro-popliteal in-stent occlusion in patients with chronic limb-threatening ischemia. Open surgery was associated with longer stay in hospital and increased use of blood transfusions. At 5 years, no significant differences were found in the rates of overall patency or limb salvage between bypass and endovascular treatment.

14.
J Endovasc Ther ; : 15266028231169164, 2023 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-37096777

RESUMEN

OBJECTIVES: To evaluate the feasibility of a standardized single-renal scallop stent-graft. DESIGN: Preclinical, single-center, real-world, all-comers, retrospective cohort study. METHODS: A total of 1347 abdominal aortic aneurysm (AAA) repairs (endovascular and open) performed between 2010 and 2020 were screened for elective treatment and retrievable preoperative high-quality computed tomography angiography (CTA) performed <6 months of the surgical procedure. Six hundred of the included CTAs involved prespecified measurements and a morphological assessment protocol (NCT05150873). The proximal sealing zones suitable for standard stent-graft implantations were further analyzed (N=547). The primary outcome assessed the feasibility of 2 single-renal scallop designs (10×10 mm and 15×10 mm, height × width). The feasibility was the inter-renal length ≥10 mm and ≥15 mm for prototypes #10 and #15, respectively. The secondary outcome quantified hypothetical length and surface improvements comparing those suitable for investigational devices implantation (study group) versus those not (control group). RESULTS: Of the total, 24.7% (n=135) was feasible with prototype #10. The study versus control group sealing zones were shorter (p=0.008), with a smaller surface (p=0.009) and a higher alpha angle (p=0.039). The length and surface area increased by about 25% and 23%, respectively, (both p<0.001) within the study group and became significantly better versus the control group (standard stent-graft; both p<0.001). Of the total, 7.1% (n=39) was suitable for prototype #15. The study versus control group sealing zones were shorter (p=0.148), with a smaller surface (p=0.077) and a higher alpha angle (p=0.027). The length and surface area increased by about 34% and 31%, respectively, (both p<0.001) within the study group and became significantly higher versus the control group (standard stent-graft; both p<0.001). CONCLUSIONS: The use of single-renal scalloped stent-graft might be feasible in a considerable number of AAA patients. The breakthrough stands in treating hostile AAAs presenting in mismatched renal arteries, keeping the complexity of the repair as similar as possible to standard endovascular repair with a remarkable improvement in sealing. CLINICAL IMPACT: The anatomic feasibility of a single renal stent graft for the treatment of "hostile" abdominal aortic aneurysm (AAA) with mismatched renal arteries was evaluated. The experimental device could be feasible in a considerable number of patients with AAA, approaching 25%, and demonstrate significant improvements in sealing. As far as we know, this is the first paper to report the prevalence of mismatched renal arteries in a large cohort of AAA patients in the real world, while proposing a dedicated device. The breakthrough is to keep the complexity of the repair as close as possible to standard endovascular repair.

15.
J Endovasc Ther ; : 15266028231161489, 2023 Mar 24.
Artículo en Inglés | MEDLINE | ID: mdl-36960843

RESUMEN

PURPOSE: To analyze the learning curve for thoracic endovascular aortic repair (TEVAR) in a single center over a period of 25 years. MATERIALS AND METHODS: In total, 390 consecutive standard TEVAR procedures undertaken between 1996 and 2021 were included in a retrospective, observational, single-center study. Cumulative sum charts were elaborated for the entire center experience (primary outcome) as well as for the first and second implanting physicians. Data on procedural variables (contrast volume, operative and fluoroscopy time), 30-day major adverse events (MAEs) and clinical success, and endoleak and reintervention rates were secondary outcomes and subdivided into 4 quartiles of experience (Q1-Q4) or presented as first 2 versus latest 2 quartiles (Q1-Q2 vs Q3-Q4). RESULTS: The mean follow-up was 4.3±4.0 years. The center's learning curve was achieved after 75 procedures, and it was similar for the first implanting physician. The surgeon coming thereafter had a significantly shorter curve (10 TEVARs). Comparing Q1-Q2 with Q3-Q4, 30-day MAEs (16.1 vs 11.3%, p=0.164), 30-day mortality (11.4% vs 3.6%, p=0.003), and intraoperative additional maneuvers (21.5% vs 13.3%, p=0.033) were reduced along with an improvement in clinical success (85.9% vs 90.3%, p=0.190). From Q1 to Q4, operative time (139.8±65.5 to 76.7±43.7 min, p=0.001), fluoroscopy time (15.1±8.8 to 7.1±5.1 min, p<0.001), and contrast volume (244.0±112.1 to 104.3±46.1 mL, p<0.001) showed a considerable reduction. Late endoleak and aortic-related mortality declined significantly from Q1-Q2 to Q3-Q4 (24.1% to 15.5%, p=0.033 and 18.6% vs 8.2%, p=0.006, respectively). Operative time (p=0.021), contrast volume (p=0.016), and fluoroscopy time (p=0.004) were independent risk factors for endoleak, causing a 1.3-fold risk increase for both each 60 minutes of additional operative time (p=0.021) and every 100 mL of additional contrast medium (p=0.016). Each 10-minute increase in fluoroscopy time determined a 1.4-fold risk increment (p=0.004). CONCLUSION: The learning curve shortened significantly over time with non-negligible clinical outcome improvements, suggesting that specific endovascular training is mandatory to become an effective TEVAR performer. CLINICAL IMPACT: For the first time in literature, the standard TEVAR's learning curve has been evaluated at a single vascular surgery center over a period of 25 years. The learning curve for the center and the first physician historically undertaking TEVAR was achieved at the 75th treated patient. The learning curve of the surgeons coming thereafter was significantly shorter (10 cases). This quarter-century demonstrated that intraoperative learning-related variables were associated with long-term clinical outcomes and all have improved over time. Centers approaching TEVAR for the first time and training program providers could use these data to aim to offer better clinical outcomes.

16.
J Endovasc Ther ; : 15266028231175621, 2023 May 26.
Artículo en Inglés | MEDLINE | ID: mdl-37232138

RESUMEN

INTRODUCTION: The aim of this study was to present the short-term and 2-year outcomes after use of the Bentley BeGraft as bridging stent-graft (BSG) for reno-visceral target vessel (TV) during fenestrated endovascular aortic repair (FEVAR) from a contemporary multicentric experience. METHODS: A retrospective review of all consecutive patients who underwent elective FEVAR at 7 institutions located in Italy from 2015 to 2021 was performed. The main outcomes of interest for this study were technical success and TV instability, defined in accordance with current reporting standards. Patients' survival was also assessed. RESULTS: Overall, 81 patients received elective FEVAR during the study period. Mean age of patients was 78 years, and 89% were men. Most patients were treated for a juxta-pararenal abdominal aortic aneurysm (AAA) (68%), and 23% had already received an infrarenal aortic reconstruction. Most endografts had 3-vessel or 4-vessel design (27% and 55%, respectively), and a Cook endograft was used in 73% of cases. Overall, 266 Bentley BeGraft were implanted, of which 44 (16.5%) in the celiac trunk, 69 (26%) in the superior mesenteric artery, 79 (29.5%) in the right renal artery, and 74 (28%) in the left renal artery. Technical success was 94%, with 5 instances of technical failure that were recorded and required an additional intraoperative procedure. The early mortality rate was 4%, and acute kidney injury occurred in 14 cases with 1 requiring definitive hemodialysis. Survival at 6, 12, and 24 months in the overall cohort was 98.8%, 95.3%, and 83.4%, respectively. Freedom from TV instability at 6, 12, and 24 months in the overall cohort was 98.4%, 97.9%, and 97.2%, respectively. Events of TV instability included 3 cases of type 1C endoleak and 3 cases of type 3C endoleak, while no events of BSG fracture or thrombosis were noted. Five out of 6 cases of TV instability occurred in renal arteries, and they were all successfully treated by endovascular means. CONCLUSIONS: The data from this multicentric study show favorable short-term and 2-year outcomes of the Bentley BeGraft as BSG for reno-visceral TV during FEVAR, with low rates of TV-related endoleak and no stent occlusion up to 2 years. CLINICAL IMPACT: The data from this multicentric study show satsfactory outcomes up to two years of follow-up for the Bentley BeGraft when used for brdiging reno-visceral vessels during fenestrated endovascular aortic repair. Further research will be needed to identify predictors of stent-related reinterventions and ascertain the long-term durability.

17.
J Endovasc Ther ; : 15266028221149922, 2023 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-36683380

RESUMEN

PURPOSE: To evaluate the outcomes of preserving the internal iliac artery (IIA) with iliac branched devices (IBDs) during acute endovascular repair of ruptured aortoiliac aneurysms. MATERIAL AND METHODS: This is a multicenter retrospective review of all consecutive patients undergoing acute endovascular repair of ruptured aortoiliac aneurysm with an IBD at 8 aortic centers between December 2012 and June 2020. A control group was used where the IIA was intentionally occluded from the same study period. The main outcome measures were 30-day mortality, major adverse events, technical success, and clinical success. Secondary outcomes were buttock claudication, primary patency, primary-assisted and secondary patency of the IBD, occurrence of endoleak types I/III, and reintervention. Values are presented as numbers and percentages or interquartile range in parenthesis. RESULTS: Forty-eight patients were included in the study: 24 with IBD and 24 with IIA occlusion. There was no difference in demographics, cardiovascular risk factors, and aneurysm extent. Twenty (83%) of them were hemodynamically stable during the procedure as opposed to 14 (58%, p=.23) with the IIA occlusion. Technical success was achieved in all cases with a procedure time of 180 (133-254) minutes, 45 (23-65) of which were from IBD. There were 2 (8%) deaths during the first 30 days and 2 (8%) major complications unrelated to the IBD, whereas in the IIA occlusion, the figures were 10 (42%) and 7 (29%), respectively. No patient in the IBD group developed buttock claudication compared to 8 (57%, p<.0001) in the IIA occlusion group; 1 (4%) patient developed bowel ischemia on both groups, with 1 in the IIA occlusion group needing resection. The median follow-up duration was 17 months (interquartile range 2-39) for the IBD group, with a primary patency of 60±14% at 3 years that went up to 92±8% with reinterventions (8 reinterventions in 6 patients). When the first 90 days were disregarded, there were no differences in survival between the groups. CONCLUSION: IBD is a valid alternative for maintaining the pelvic circulation for endovascular aortic aneurysm repair of ruptured aortoiliac aneurysms. The technical success and midterm outcomes are very satisfactory but require patient selection particularly regarding hemodynamic stability. The reintervention rate is considerable, mandating continuous follow-up. CLINICAL IMPACT: This multicenter study demonstrates that ruptured aortoiliac aneurysms do not necessarily require mandatory occlusion of hypogastric arteries. Iliac branch devices are shown to be a valid alternative in highly selected cases, with good midterm results, even if reinterventions are required in a significant proportion of patients.

18.
Eur J Vasc Endovasc Surg ; 66(1): 38-48, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36963748

RESUMEN

OBJECTIVE: To assess the real world incidence, outcomes, and risk factors of type III endoleaks (TIIIEL) after endovascular aneurysm repair (EVAR). METHODS: This was a single centre, retrospective, observational, cohort study. All patients with abdominal aortic aneurysms (AAAs) receiving EVAR between 1994 and 2020 were collected prospectively and reviewed. The primary outcome was the cumulative incidence and impact on survival of TIIIELs, either defined as disconnections of modular graft components (TIIIaEL) or fabric defects (TIIIbEL). Secondary outcomes included risk factor analysis evaluating baseline morphological and stent graft details, as well as a comparison of TIIIaEL and TIIIbEL. RESULTS: In total, 2 565 EVARs were performed and 95 (3.7%) TIIIELs were diagnosed at a median interval of 49.5 months (interquartile range [IQR] 19.4, 67.6). Estimated TIIIEL incidence at five years was 6.8%, 2.2%, and 3.6% for first and second generation, third and fourth generation, and fifth and sixth generation, respectively. The survival rate in patients without any high flow endoleak was 88.0%, 67.9%, 56.9%, and 52.1%, while in TIIIEL patients it was 98.6%, 77.2%, 49.8%, and 32.3% at one, five, 10, and 15 years, respectively (p = .77). The distribution of TIIIaEL and TIIIbEL was 70.5% and 29.5%, respectively. TIIIbEL received a higher rate of open treatment (28.6% vs. 7.5%; p = .005) and device or procedure related re-interventions (35.7% vs. 13.4%; p = .013). Fourteen (15.4%) recurrent TIIIELs were diagnosed at a median of 16.8 months (IQR 7.6, 32.1). Old generation endografts (hazard ratio [HR] 2.1, 95% confidence interval [CI] 1.3 - 3.4; p = .002) and non-proprietary extensions (HR 3.6, 95% CI 1.9 - 6.8; p < .001), and angulated and calcified aneurysm neck (HR 3.6, 95% CI 1.2 - 10.6; p = .017) were risk factors for TIIIEL. Every 10 mm maximum AAA diameter increase presented a 1.4 fold higher risk of TIIIEL. CONCLUSION: TIIIEL is a severe condition that is often fatal if left untreated. Old endografts, the implantation of non-proprietary extensions, large AAAs, and angulated and calcified necks are risk factors for TIIIEL that require careful follow up due to the high rate of recurrence.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Endofuga/diagnóstico por imagen , Endofuga/epidemiología , Endofuga/etiología , Prótesis Vascular/efectos adversos , Incidencia , Estudios Retrospectivos , Estudios de Cohortes , Resultado del Tratamiento , Factores de Riesgo
19.
Eur J Vasc Endovasc Surg ; 66(1): 77-84, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37084878

RESUMEN

OBJECTIVE: This study aimed to evaluate the safety and effectiveness of the Penumbra Indigo percutaneous aspiration thrombectomy (PAT) system in the clinical presentation of iliac limb occlusion (ILO) after endovascular aortic repair (EVAR). METHODS: A retrospective, observational, multicentre study conducted in eight Italian vascular centres. Consecutive patients presenting with ILO after EVAR were eligible. To assess vessel revascularisation, Thrombo-aspiration In Peripheral Ischaemia (TIPI) classification (score 0-3) was used at presentation (t1), after PAT (t2), and after adjunctive procedures (t3). Successful revascularisation was considered TIPI 2-3 (near complete or complete). Primary intra-operative outcomes were technical success (TS) of Indigo PAT and combined TS of PAT associated with adjunctive procedures when needed. Primary follow up outcomes were safety and effectiveness at one, six, and 12 months. RESULTS: From September 2019 to December 2021, there were 48 ILO and 17 patients (35%) [median age 75 years, IQR 71, 83 years; male, 14 (82%); urgent, 8 (47%)] were treated and enrolled. The median time after primary EVAR was 24 months (IQR 0, 42 months). The median clot age from ILO diagnosis to PAT was three days (IQR 1, 12 days). Ten patients (59%) presented with limb threatening ischaemia. At t1, TIPI 0 and 1 was present in 13 (76%) and four (24%) cases, respectively. At t2, primary TS (TIPI 2-3) was achieved in 14 cases (82%) after Indigo PAT (p < .001). Fifteen patients (88%) required adjunctive procedures (14 re-linings, one surgical patch angioplasty). At t3, combined TS was achieved in 16 cases (94%). Intra-operative complication included one (6%) distal embolisation, treated successfully. The 30 day mortality was one case (6%) due to pneumonia. At one, six, and 12 months, clinical success was 100% without ILO recurrence. The median follow up was 23 months (IQR 11, 41 months): at 18 months, survival and freedom from re-intervention were 91 ± 8% and 90 ± 9%, respectively. CONCLUSION: This study reports for the first time the efficacy and safety of Penumbra Indigo PAT for ILO after EVAR, with promising technical and clinical success up to one year.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Masculino , Anciano , Prótesis Vascular , Carmin de Índigo , Implantación de Prótesis Vascular/métodos , Estudios Retrospectivos , Resultado del Tratamiento , Aneurisma de la Aorta Abdominal/cirugía , Diseño de Prótesis , Factores de Riesgo , Trombectomía/efectos adversos , Isquemia/diagnóstico por imagen , Isquemia/etiología , Isquemia/cirugía , Sistema de Registros , Procedimientos Endovasculares/efectos adversos
20.
Eur J Vasc Endovasc Surg ; 65(6): 811-817, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36871927

RESUMEN

OBJECTIVE: The aim of this study was to investigate the early outcomes of a novel off the shelf pre-loaded inner branched thoraco-abdominal endograft (E-nside) in the treatment of aortic pathologies. METHODS: Data from a physician initiated national multicentre registry on patients treated with the E-nside endograft, were prospectively collected and analysed. Pre-operative clinical and anatomical characteristics, procedural data, and early outcomes (90 days) were recorded in a dedicated electronic data capture system. The primary endpoint was technical success. Secondary endpoints were early mortality (90 days), procedural metrics, target vessel patency, endoleak rate, and major adverse events (MAEs) at 90 days. RESULTS: In total, 116 patients from 31 Italian centres were included. Mean ± standard deviation (SD) patient age was 73 ± 8 years and 76 (65.5%) were male. Aortic pathologies included degenerative aneurysm in 98 (84.5%), post-dissection aneurysm in five (4.3%), pseudoaneurysm in six (5.2%), penetrating aortic ulcer or intramural haematoma in four (3.4%), and subacute dissection in three (2.6%). Mean ± SD aneurysm diameter was 66 ± 17 mm; aneurysm extent was Crawford I - III in 55 (50.4%), IV in 21 (19.2%), pararenal in 29 (26.7%), and juxtarenal in four (3.7%). The procedure setting was urgent in 25 (21.5%) patients. Median procedural time was 240 minutes (interquartile range [IQR] 195, 303), with a median contrast volume of 175 mL (IQR 120, 235). The endograft's technical success rate was 98.2% and the 90 day mortality rate was 5.2% (n = 6; 2.1% for elective repair and 16% for urgent repair). The 90-days cumulative MAE rate was 24.1% (n = 28). At 90 days, there were 10 (2.3%) target vessel related events (nine occlusions and one type IC endoleak) and one type 1A endoleak requiring re-intervention. CONCLUSION: In this real life, non-sponsored registry, the E-nside endograft was used for the treatment of a broad spectrum of aortic pathologies, including urgent cases and different anatomies. The results showed excellent technical implantation safety and efficacy, as well as early outcomes. Longer term follow up is needed to better define the clinical role of this novel endograft.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA