Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 47(5): 635-641, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38552167

RESUMEN

BACKGROUND: The stretching of the lead caused by somatic growth may lead to complications (dislodgement, fracture, failure) of transvenous leads implanted in pediatric patients. Atrial loop and absorbable ligatures may prevent it. Periodical lead advancement with lead pushing from the pocket may be an option to growth-induced stretching. Our aim was to analyze retrospectively the outcome of periodical transvenous lead advancement in children with pacemaker (PM). METHODS: A procedure of lead advancement was performed in patients with a single-chamber PM implanted for isolated congenital complete atrioventricular block or sinus node dysfunction with growth-induced lead straightening/stretching. The PM pocket was opened, the lead was released from subcutaneous adherences and was gently advanced to shape again a loop/semi-loop in the atrium without dislodging the tip. Lead data (threshold, sensing, impedance) were compared before and after the procedure. Data are described as median (25th-75th centiles). RESULTS: 14 patients with 13 VVIR and 1 AAIR PM implanted at 6.8 (5.9-8.0) years of age, 23 (19-26) kg, 118 (108-124) cm, underwent 30 advancement procedures, 1.5 (1.0-2.3) per patient, during follow-up [45 (35-63) months]. Delta between procedures was: 18 (14-25) months, 11 (7-13) cm, 6 (4-9) kg; 90% of leads were successfully advanced without complications. Three unsuccessful procedures occurred with longer times [30 (14-37) months]. Electrical lead parameters did not show significant differences pre-/post-procedures. CONCLUSION: the advancement of transvenous leads in children seems safe and effective. This procedure may be another possible choice to preserve transvenous lead position and function until growth has completed.


Asunto(s)
Marcapaso Artificial , Humanos , Masculino , Femenino , Estudios Retrospectivos , Niño , Preescolar , Electrodos Implantados , Bloqueo Atrioventricular/terapia , Síndrome del Seno Enfermo/terapia
2.
Europace ; 25(4): 1482-1490, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36794445

RESUMEN

AIMS: In congenitally corrected transposition of the great arteries (CCTGA) the right ventricle (RV) is systemic. Atrioventricular block (AVB) and systolic dysfunction are frequently observed. Permanent pacing of the subpulmonary left ventricle (LV) may worsen RV dysfunction. The aim of this study was to seek out if LV conduction system pacing (LVCSP) guided by three-dimensional-electroanatomic mapping systems (3D-EAMs) can preserve RV systolic function in paediatric CCTGA patients with AVB. METHODS AND RESULTS: Retrospective analysis of CCTGA patients who underwent 3D-EAM-guided LVCSP. Three-dimensional-pacing map guided lead implantation towards septal sites with narrower paced QRS. Electrocardiograms (ECGs), echocardiograms, and lead parameters (threshold, sensing, and impedance) were compared at baseline (pre-implantation) and at 1-year follow-up. Right ventricle function was evaluated by 3D ejection fraction (EF), fractional area change (FAC), RV global longitudinal strain (GLS). Data are reported as median (25th-75th centiles). Seven CCTGA patients aged 15 (9-17) years, with complete/advanced AVB (4 with prior epicardial pacing), underwent 3D-guided LVCSP (5 DDD, 2 VVIR). Baseline echocardiographic parameters were impaired in most patients. No acute/chronic complications occurred. Ventricular pacing was >90%. At 1-year follow-up QRS duration showed no significant changes compared with baseline; however, QRS duration shortened in comparison with prior epicardial pacing. Lead parameters remained acceptable despite ventricular threshold increased. Systemic RV function was preserved: FAC and GLS improved significantly, and all patients showed normal RV EF (>45%). CONCLUSION: Three-dimensional-EAM-guided LVCSP preserved RV systolic function in paediatric patients with CCTGA and AVB after short-term follow-up.


Asunto(s)
Bloqueo Atrioventricular , Transposición de los Grandes Vasos , Humanos , Niño , Transposición Congénitamente Corregida de las Grandes Arterias/complicaciones , Transposición de los Grandes Vasos/complicaciones , Transposición de los Grandes Vasos/diagnóstico por imagen , Transposición de los Grandes Vasos/terapia , Estudios Retrospectivos , Sistema de Conducción Cardíaco , Ventrículos Cardíacos/diagnóstico por imagen , Estimulación Cardíaca Artificial/métodos
3.
Europace ; 25(2): 460-468, 2023 02 16.
Artículo en Inglés | MEDLINE | ID: mdl-36107451

RESUMEN

AIMS: Subcutaneous-implantable cardiac defibrillators (S-ICDs) are used increasingly to prevent sudden cardiac death in young patients. This study was set up to gain insight in the indications for S-ICD, possible complications, and their predictors and follow-up results. METHODS AND RESULTS: A multicentre, observational, retrospective, non-randomized, standard-of-care registry on S-ICD outcome in young patients with congenital heart diseases (CHDs), inherited arrhythmias (IAs), idiopathic ventricular fibrillation (IVF), and cardiomyopathies (CMPs). Anthropometry was registered as well as implantation technique, mid-term device-related complications, and incidence of appropriate/inappropriate shocks (IASs). Data are reported as median (interquartile range) or mean ± standard deviation. Eighty-one patients (47% CMPs, 20% CHD, 21% IVF, and 12% IA), aged 15 (14-17) years, with body mass index (BMI) 21.8 ± 3.8 kg/m2, underwent S-ICD implantation (primary prevention in 59%). This was performed with two-incision technique in 81% and with a subcutaneous pocket in 59%. Shock and conditional zones were programmed at 250 (200-250) and 210 (180-240) b.p.m., respectively. No intraoperative complications occurred. Follow up was 19 (6-35) months: no defibrillation failure occurred, 17% of patients received appropriate shocks, 13% of patients received IAS (supraventricular tachycardias 40%, T-wave oversensing 40%, and non-cardiac oversensing 20%). Reprogramming, proper drug therapy, and surgical revision avoided further IAS. Complications requiring surgical revision occurred in 9% of patients, with higher risks in patients with three-incision procedures [hazard ratio (HR) 4.3, 95% confidence interval (95% CI) 0.5-34, P = 0.038] and BMI < 20 (HR 5.1, 95% CI 1-24, P = 0.031). CONCLUSION: This multicentre European paediatric registry showed good S-ICD efficacy and safety in young patients. Newer implantation techniques and BMI > 20 showed better outcome.


Asunto(s)
Desfibriladores Implantables , Cardiopatías Congénitas , Humanos , Niño , Adulto Joven , Estudios Retrospectivos , Resultado del Tratamiento , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiología , Arritmias Cardíacas/terapia , Desfibriladores Implantables/efectos adversos , Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Sistema de Registros , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/epidemiología
4.
Europace ; 25(9)2023 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-37536671

RESUMEN

AIMS: Patients with cardiomyopathies and channelopathies are usually younger and have a predominantly arrhythmia-related prognosis; they have nearly normal life expectancy thanks to the protection against sudden cardiac death provided by the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) is an effective alternative to the transvenous ICD and has evolved over the years. This study aimed to evaluate the rate of inappropriate shocks (IS), appropriate therapies, and device-related complications in patients with cardiomyopathies and channelopathies who underwent modern S-ICD implantation. METHODS AND RESULTS: We enrolled consecutive patients with cardiomyopathies and channelopathies who had undergone implantation of a modern S-ICD from January 2016 to December 2020 and who were followed up until December 2022. A total of 1338 S-ICD implantations were performed within the observation period. Of these patients, 628 had cardiomyopathies or channelopathies. The rate of IS at 12 months was 4.6% [95% confidence interval (CI): 2.8-6.9] in patients with cardiomyopathies and 1.1% (95% CI: 0.1-3.8) in patients with channelopathies (P = 0.032). No significant differences were noted over a median follow-up of 43 months [hazard ratio (HR): 0.76; 95% CI: 0.45-1.31; P = 0.351]. The rate of appropriate shocks at 12 months was 2.3% (95% CI: 1.1-4.1) in patients with cardiomyopathies and 2.1% (95% CI: 0.6-5.3) in patients with channelopathies (P = 1.0). The rate of device-related complications was 0.9% (95% CI: 0.3-2.3) and 3.2% (95% CI: 1.2-6.8), respectively (P = 0.074). No significant differences were noted over the entire follow-up. The need for pacing was low, occurring in 0.8% of patients. CONCLUSION: Modern S-ICDs may be a valuable alternative to transvenous ICDs in patients with cardiomyopathies and channelopathies. Our findings suggest that modern S-ICD therapy carries a low rate of IS. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Asunto(s)
Cardiomiopatías , Canalopatías , Desfibriladores Implantables , Humanos , Desfibriladores Implantables/efectos adversos , Canalopatías/complicaciones , Canalopatías/terapia , Resultado del Tratamiento , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Cardiomiopatías/complicaciones , Cardiomiopatías/terapia , Sistema de Registros
5.
Pacing Clin Electrophysiol ; 46(10): 1162-1169, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37614072

RESUMEN

BACKGROUND: Cardiac pacing from right ventricular (RV) sites may cause electromechanical ventricular dyssynchrony. Invasive and noninvasive mapping studies showed left ventricular (LV) activation sequence in adults. Aim of this study was to seek out the LV endocardial activation (LVEA) in pediatric patients who underwent RV pacing. METHODS: Single-center, prospective study conducted on pediatric patients who underwent left sided catheter ablation of accessory pathways with the Carto Univu mapping system. After successful ablation procedures, LVEA was recorded by the ablation catheter during sinus rhythm (SR) and during para-hisian (PHP), midseptum (MSP), and apical (RVAP) pacing. RESULTS: Seventeen patients, 13 males, aged 12 (10-15) years, registered LV activation maps and times (LVAT). SR showed significantly shorter LVAT than during pacing. LVAT of PHP was shorter than MSP, while there were not significant differences among PHP and MSP versus RVAP. In SR initial LV endocardial activation occurred in two midseptum sites, inferior-posterior and superior-anterior. During PHP, initial activation occurred at parahisian basal septum, rapidly followed by midseptum as in SR. During MSP and RVAP initial activation occurred at midseptum and apex, respectively. From all initial sites, the excitation spreads toward the base of the lateral LV free wall. A mild linear correlation was found between QRS duration and LVAT for MSP and for PHP. CONCLUSIONS: In pediatric patients LVEA maps during RV pacing showed that the shortest LVAT was obtained with PHP. The LV activation pattern seemed similar in sinus rhythm, PHP and MSP, from midseptum to LV lateral base.


Asunto(s)
Estimulación Cardíaca Artificial , Función Ventricular Izquierda , Masculino , Adulto , Humanos , Niño , Estudios Prospectivos , Función Ventricular Izquierda/fisiología , Estimulación Cardíaca Artificial/métodos , Ventrículos Cardíacos/cirugía , Arritmias Cardíacas
6.
Pacing Clin Electrophysiol ; 46(6): 543-547, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36815543

RESUMEN

The recently published "electrophysiologically guided low-voltage bridge (LVB) strategy" is effective in the ablation of atrioventricular nodal re-entry tachycardia (AVNRT) in children. This study aimed to evaluate its efficacy and safety in children <26 kgs. Fourteen children [64% males, median age 6.5 years (IQR 6-8 years), median weight 25.5 kg (IQR 24-26 kg)] with AVNRT were treated. In all patients, we detected a LVB associated to a typical slow pathway potential. The acute success rate was 100% with a mean of 5.5 cryoablation deliveries. All procedures were performed with near-zero fluoroscopic exposure (median time 0.15 min, IQR 0-0.7 min), in six patients fluoroscopy was 0 min. There were no complications or recurrences during the follow-up (median 20.91 months, IQR 11.7-26.7 months).


Asunto(s)
Ablación por Catéter , Criocirugía , Taquicardia por Reentrada en el Nodo Atrioventricular , Masculino , Humanos , Niño , Femenino , Criocirugía/métodos , Resultado del Tratamiento , Potenciales de Acción , Factores de Tiempo , Recurrencia
7.
Pediatr Cardiol ; 44(8): 1736-1740, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37597120

RESUMEN

The autosomal recessive (AR) form of Long QT Syndrome (LQTS) is described both associated with deafness known as Jervell and Lange-Nielsen (JLN) syndrome, and without deafness (WD). The aim of the study is to report the characteristics of AR LQTS patients and the efficacy of the therapy. Data of all children with AR LQTS referred to the Bambino Gesù Children's Hospital IRCCS from September 2012 to September 2021were included. Three (30%) patients had compound heterozygosity and 7 (70%) had homozygous variants of the KCNQ1 gene, the latter showing deafness. Four patients (40%) presented aborted sudden cardiac death (aSCD): three with previous episodes of syncope (75%), the other without previous symptoms (16.6% of asymptomatic patients). An episode of aSCD occurred in 2/3 (66.7%) of WD and heterozygous patients, while in 2/7 (28%) JLN and homozygous patients and in 2/2 patients with QTC > 600 ms. All patients were treated with Nadolol. In 5 Mexiletine was added, shortening QTc and obtaining the disappearance of the T-wave alternance (TWA) in 3/3. Episodes of aSCD seem to be more frequent in LQTS patients with compound heterozygous variants and WD than in those with JLN and homozygous variants. Episodes of aSCD also appear more frequent in children with syncope or with QTc value > 600 ms, even on beta-blocker therapy, than in patients without syncope or with Qtc < 600 ms. However, our descriptive results should be confirmed by larger studies. Moreover, Mexiletine addition reduced QTc value and eliminated TWA.


Asunto(s)
Sordera , Paro Cardíaco , Síndrome de Jervell-Lange Nielsen , Síndrome de QT Prolongado , Niño , Humanos , Canal de Potasio KCNQ1/genética , Mexiletine/uso terapéutico , Síndrome de QT Prolongado/tratamiento farmacológico , Síndrome de QT Prolongado/genética , Síndrome de QT Prolongado/diagnóstico , Síndrome de Jervell-Lange Nielsen/tratamiento farmacológico , Síndrome de Jervell-Lange Nielsen/genética , Síndrome de Jervell-Lange Nielsen/diagnóstico , Síncope/genética
8.
Cardiol Young ; 33(5): 760-765, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-35673795

RESUMEN

BACKGROUND: Permanent pacing in children with isolated congenital complete atrioventricular block may cause left ventricular dysfunction. To prevent it, alternative pacing sites have been proposed: left ventricular epicardial or selective right ventricular endocardial pacing. AIMS: To compare the functional outcome (left ventricular systolic function and synchrony) in paediatric patients with congenital complete atrioventricular block and left ventricular apical epicardial or right ventricular transvenous mid-septal pacing. METHODS: Retrospective study. Epicardial leads were implanted by standard surgical technique, transvenous leads by 3D electroanatomic mapping systems. 3D mapping acquired 3D right ventricular local pacing map and defined the narrowest paced QRS site. 3D mapping guided screw-in bipolar leads on that ventricular site. Electrocardiogram (ECG) (QRS duration) and echocardiographic data (synchrony: interventricular mechanical delay, septal to posterior wall motion delay, systolic dyssynchrony index; contractility: global longitudinal strain, ejection fraction) were recorded. Data are reported as median [interquartile ranges]. p < 0.05 was significant. RESULTS: There were 19 transvenous systems (age 8.8 [6-14] years; right ventricular mid-septum) and 17 epicardial systems (0.04 [0.001-0.6] years; left ventricular apex). Post-implantation QRS significantly widened either in endocardial or in epicardial patients. Most patients reached 4-year follow-up. One-year and 4-year ejection fraction and global longitudinal strain were mostly within normal limits and did not show significant differences between the two groups and between the same endocardial/epicardial group. Synchrony parameters were within normal limits in the two groups. CONCLUSIONS: Left ventricular apical epicardial pacing and 3D mapping-guided right ventricular mid-septal pacing preserved left ventricular contractility and synchrony in children and adolescents with congenital complete atrioventricular block at short-/mid-term follow-up, without relevant significant differences between the two groups.


Asunto(s)
Bloqueo Atrioventricular , Estimulación Cardíaca Artificial , Adolescente , Humanos , Niño , Bloqueo Atrioventricular/terapia , Estudios Retrospectivos , Resultado del Tratamiento , Función Ventricular Izquierda
9.
Cardiol Young ; 32(8): 1229-1234, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34586049

RESUMEN

INTRODUCTION: The aim of the study was to revise our more recent experience about epicardial posterior-septal accessory pathways radiofrequency transcatheter ablation in children and young patients using a transvenous approach through the coronary sinus, to understand if new mapping and ablation technologies can increase success rate and safety. METHODS AND RESULTS: Twenty children (mean age 13 ± 3 years) with epicardial posterior-septal accessory pathways (14 in coronary sinus and 6 in the middle cardiac vein) underwent radiofrequency transcatheter ablation with CARTO-3® system with help of the CARTO-Univu® module. Acute success rate was 73%. No patient was lost to follow-up (mean time 11.4 ± 9 months). The recurrence rate was 19%. Two patients underwent a successful redo-procedure; the overall long-term success rate was 65%. Navistar® catheter presented the highest acute success rate in the coronary sinus. Navistar SmartTouch® was the only catheter that did not present recurrences after the acute success, and it was successfully used in two patients previously unsuccessfully treated with a Navistar ThermoCool®. Acute success rate was 79% without image integration with angio-CT, while it was 63% after the introduction of CARTO-Merge®. CONCLUSION: Epicardial posterior-septal accessory pathways can be definitively eliminated by transvenous radiofrequency transcatheter ablation in more than half of the cases in children. Acute success rate does not seem to depend on catheters used, but contact-force catheter seems to be useful in cases with recurrences. Image integration with cardiac-CT does not increase success rate, but it is useful to detect coronary sinus alterations to better guide ablation strategy.


Asunto(s)
Fascículo Atrioventricular Accesorio , Ablación por Catéter , Seno Coronario , Adolescente , Ablación por Catéter/métodos , Niño , Humanos , Tecnología
10.
Europace ; 23(2): 271-277, 2021 02 05.
Artículo en Inglés | MEDLINE | ID: mdl-33038208

RESUMEN

AIMS: In the current literature, results of the low-voltage bridge (LVB) ablation strategy for the definitive treatment of atrioventricular nodal re-entry tachycardia (AVNRT) seem to be encouraging also in children. The aims of this study were (i) to prospectively evaluate the mid-term efficacy of LVB ablation in a very large cohort of children with AVNRT, and (ii) to identify electrophysiological factors associated with recurrence. METHODS AND RESULTS: One hundred and eighty-four children (42% male, mean age 13 ± 4 years) with AVNRT underwent transcatheter cryoablation guided by voltage mapping of the Koch's triangle. Acute procedural success was 99.2% in children showing AVNRT inducibility at the electrophysiological study. The overall recurrence rate was 2.7%. The presence of two LVBs, a longer fluoroscopy time and the presence of both typical and atypical AVNRT, were found to be significantly associated with an increased recurrence rate during mid-term follow-up. Conversely, there was no significant association between recurrences and patient's age, type of LVB, lesion length, number of cryolesions or catheter tip size. CONCLUSION: The LVB ablation strategy is very effective in AVNRT treatment in children. Recurrences are related to the complexity of the arrhythmogenic substrate.


Asunto(s)
Ablación por Catéter , Criocirugía , Taquicardia por Reentrada en el Nodo Atrioventricular , Adolescente , Niño , Estudios de Cohortes , Criocirugía/efectos adversos , Femenino , Humanos , Masculino , Recurrencia , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Resultado del Tratamiento
11.
Europace ; 23(6): 948-957, 2021 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-33336258

RESUMEN

AIMS: The aims of this study are to evaluate the progressive involvement of the cardiac conduction system in the Kearn-Sayre syndrome (KSS) and to establish criteria for the prevention of episodes of syncope or sudden cardiac death. METHODS AND RESULTS: This is a prospective monocentric study including KSS patients, with diagnosis based on clinical manifestations, muscle biopsy, and genetic tests, before the age of 18. All patients underwent cardiac screening examination with 12-lead electrocardiogram (ECG), 24-h Holter monitoring, and pacemaker (PM) interrogation twice a year. Fifteen patients (nine males, mean age 16.6 ± 3.9 years) with a sporadic KSS were recruited. All subjects manifested at least one of the intraventricular conduction defects (IVDs): 1 right bundle branch block (RBBB), 2 left anterior fascicular block (LAFB), 11 a bi-fascicular block (RBBB + LAFB), and 1 left posterior fascicular block. Most children with bi-fascicular block developed LAFB before the RBBB (P = 0.0049). In six patients, IVD degenerated into atrioventricular block (AVB). Endocavitary PM was implanted in 11 patients (6 with AVB and 5 with a bi-fascicular block), while an implantable cardioverter-defibrillator only in one patient with a non-sustained ventricular tachycardia. Four died at mean age of 14.7 ± 2.6 years, but none of them suddenly. CONCLUSION: Even a 'simple' ECG can predict the arrhythmic risk and the occurrence of catastrophic events in young patients with KSS. Left anterior fascicular block precedes RBBB in determining the bi-fascicular block and this can predict an inexorable progression of the conduction defects even in a short time. Pacemaker implantation may be indicated in these patients since the first bi-fascicular block manifestation.


Asunto(s)
Bloqueo Atrioventricular , Síndrome de Kearns-Sayre , Adolescente , Adulto , Bloqueo Atrioventricular/diagnóstico , Bloqueo Atrioventricular/terapia , Niño , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Electrocardiografía , Sistema de Conducción Cardíaco , Humanos , Masculino , Estudios Prospectivos , Adulto Joven
12.
Pediatr Cardiol ; 42(7): 1650-1652, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34378100

RESUMEN

We report a unique case of a 6-year-old male child with aborted sudden cardiac death due to ventricular fibrillation. A rare anomalous aortic origin of the right coronary artery was detected and supposed to be the cause of the malignant arrhythmia. Clinical exome sequencing did not reveal any pathogenic variant related to channelopathies nor other known heart-related genes. The patient underwent cardiac surgery and a cardiac defibrillator was implanted for secondary prevention.


Asunto(s)
Paro Cardíaco , Fibrilación Ventricular , Arritmias Cardíacas , Niño , Muerte , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Humanos , Masculino , Fibrilación Ventricular/etiología , Fibrilación Ventricular/terapia
13.
Cardiol Young ; 31(11): 1738-1769, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34338183

RESUMEN

In view of the increasing complexity of both cardiovascular implantable electronic devices (CIEDs) and patients in the current era, practice guidelines, by necessity, have become increasingly specific. This document is an expert consensus statement that has been developed to update and further delineate indications and management of CIEDs in pediatric patients, defined as ≤21 years of age, and is intended to focus primarily on the indications for CIEDs in the setting of specific disease categories. The document also highlights variations between previously published adult and pediatric CIED recommendations and provides rationale for underlying important differences. The document addresses some of the deterrents to CIED access in low- and middle-income countries and strategies to circumvent them. The document sections were divided up and drafted by the writing committee members according to their expertise. The recommendations represent the consensus opinion of the entire writing committee, graded by class of recommendation and level of evidence. Several questions addressed in this document either do not lend themselves to clinical trials or are rare disease entities, and in these instances recommendations are based on consensus expert opinion. Furthermore, specific recommendations, even when supported by substantial data, do not replace the need for clinical judgment and patient-specific decision-making. The recommendations were opened for public comment to Pediatric and Congenital Electrophysiology Society (PACES) members and underwent external review by the scientific and clinical document committee of the Heart Rhythm Society (HRS), the science advisory and coordinating committee of the American Heart Association (AHA), the American College of Cardiology (ACC), and the Association for European Paediatric and Congenital Cardiology (AEPC). The document received endorsement by all the collaborators and the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). This document is expected to provide support for clinicians and patients to allow for appropriate CIED use, appropriate CIED management, and appropriate CIED follow-up in pediatric patients.


Asunto(s)
Cardiología , Desfibriladores Implantables , American Heart Association , Electrofisiología Cardíaca , Niño , Consenso , Electrónica , Humanos , Estados Unidos
14.
Indian Pacing Electrophysiol J ; 21(6): 349-366, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34333142

RESUMEN

Guidelines for the implantation of cardiac implantable electronic devices (CIEDs) have evolved since publication of the initial ACC/AHA pacemaker guidelines in 1984 [1]. CIEDs have evolved to include novel forms of cardiac pacing, the development of implantable cardioverter defibrillators (ICDs) and the introduction of devices for long term monitoring of heart rhythm and other physiologic parameters. In view of the increasing complexity of both devices and patients, practice guidelines, by necessity, have become increasingly specific. In 2018, the ACC/AHA/HRS published Guidelines on the Evaluation and Management of Patients with Bradycardia and Cardiac Conduction Delay [2], which were specific recommendations for patients >18 years of age. This age-specific threshold was established in view of the differing indications for CIEDs in young patients as well as size-specific technology factors. Therefore, the following document was developed to update and further delineate indications for the use and management of CIEDs in pediatric patients, defined as ≤21 years of age, with recognition that there is often overlap in the care of patents between 18 and 21 years of age. This document is an abbreviated expert consensus statement (ECS) intended to focus primarily on the indications for CIEDs in the setting of specific disease/diagnostic categories. This document will also provide guidance regarding the management of lead systems and follow-up evaluation for pediatric patients with CIEDs. The recommendations are presented in an abbreviated modular format, with each section including the complete table of recommendations along with a brief synopsis of supportive text and select references to provide some context for the recommendations. This document is not intended to provide an exhaustive discussion of the basis for each of the recommendations, which are further addressed in the comprehensive PACES-CIED document [3], with further data easily accessible in electronic searches or textbooks.

15.
Indian Pacing Electrophysiol J ; 21(6): 367-393, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34333141

RESUMEN

In view of the increasing complexity of both cardiovascular implantable electronic devices (CIEDs) and patients in the current era, practice guidelines, by necessity, have become increasingly specific. This document is an expert consensus statement that has been developed to update and further delineate indications and management of CIEDs in pediatric patients, defined as ≤21 years of age, and is intended to focus primarily on the indications for CIEDs in the setting of specific disease categories. The document also highlights variations between previously published adult and pediatric CIED recommendations and provides rationale for underlying important differences. The document addresses some of the deterrents to CIED access in low- and middle-income countries and strategies to circumvent them. The document sections were divided up and drafted by the writing committee members according to their expertise. The recommendations represent the consensus opinion of the entire writing committee, graded by class of recommendation and level of evidence. Several questions addressed in this document either do not lend themselves to clinical trials or are rare disease entities, and in these instances recommendations are based on consensus expert opinion. Furthermore, specific recommendations, even when supported by substantial data, do not replace the need for clinical judgment and patient-specific decision-making. The recommendations were opened for public comment to Pediatric and Congenital Electrophysiology Society (PACES) members and underwent external review by the scientific and clinical document committee of the Heart Rhythm Society (HRS), the science advisory and coordinating committee of the American Heart Association (AHA), the American College of Cardiology (ACC), and the Association for European Paediatric and Congenital Cardiology (AEPC). The document received endorsement by all the collaborators and the Asia Pacific Heart Rhythm Society (APHRS), the Indian Heart Rhythm Society (IHRS), and the Latin American Heart Rhythm Society (LAHRS). This document is expected to provide support for clinicians and patients to allow for appropriate CIED use, appropriate CIED management, and appropriate CIED follow-up in pediatric patients.

16.
Pacing Clin Electrophysiol ; 43(6): 535-541, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32233121

RESUMEN

BACKGROUND: Small retrospective studies reported that left ventricular (LV) pacing is likely to preserve LV function in children with isolated congenital complete atrioventricular block (CCAVB). The aim of this study was to prospectively evaluate LV contractility and synchrony in a cohort of neonates/infants at pacemaker implantation and follow-up. METHODS: Patients with CCAVB who underwent LV pacing were evaluated with electrocardiogram and echocardiogram in a single-center, prospective study. Data were collected at implantation, at 1-month and every year of follow-up, up to 5 years. LV ventricular dimensions (diameters and volumes), systolic function (ejection fraction [EF] and global longitudinal strain [GLS]), and synchrony were evaluated. Data are reported as median (25th-75th centiles). RESULTS: Twenty consecutive patients with CCAVB underwent pacemaker implantation (12 single-chamber pacemaker [VVIR] and eight dual-chamber pacemaker [DDD]) with epicardial leads: 17 on the LV apex and three on the free wall. Age at implantation was 0.3 months (1 day-4.5 months). Patients showed good clinical status, normal LV dimensions, preserved systolic function, and synchrony at 60 (30-60) months follow-up. EF increased to normal values in patients with preimplantation EF <50%. Presence of antibodies and pacing mode (DDD vs VVIR) had no impact on the outcome. CONCLUSIONS: LV pacing preserved LV systolic function and synchrony in neonates and infants with CCAVB at 5-year follow-up. LV EF improved in patients with low preimplantation EF. Pacing mode or the presence of autoantibodies did not demonstrated an impact on LV contractility and synchrony.


Asunto(s)
Estimulación Cardíaca Artificial , Ecocardiografía , Electrocardiografía , Bloqueo Cardíaco/congénito , Sístole/fisiología , Función Ventricular Izquierda/fisiología , Preescolar , Femenino , Estudios de Seguimiento , Bloqueo Cardíaco/fisiopatología , Bloqueo Cardíaco/terapia , Humanos , Recién Nacido , Masculino , Estudios Prospectivos , Factores de Tiempo
17.
J Pediatr ; 201: 184-189.e2, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29961647

RESUMEN

OBJECTIVES: To assess the effect of a dedicated pediatric syncope unit on the diagnostic and therapeutic management of children with suspected syncope. We also evaluated the effectiveness of the pediatric syncope unit model in decreasing unnecessary tests and hospitalizations, minimizing social costs, and improving diagnostic yield. STUDY DESIGN: This single-center cohort observational, prospective study enrolled 2278 consecutive children referred to Bambino Gesù Children's Hospital from 2012 to 2017. Characteristics of the study population, number and type of admission examinations, and diagnostic findings before the pediatric syncope unit was implemented (2012-2013) and after the pediatric syncope unit was implemented (2014-2015 and 2016-2017) were compared. RESULTS: The proportion of undefined syncope, number of unnecessary diagnostic tests performed, and number of hospital stay days decreased significantly (P < .0001), with an overall decrease in costs. A multivariable logistic regression analysis, adjusted for confounding variables (age, sex, number of diagnostic tests), the period after pediatric syncope unit (2016-2017) resulted as the best independent predictor of effectiveness for a defined diagnosis of syncope (P < .0001). CONCLUSIONS: Pediatric syncope unit organization with fast-tracking access more appropriate diagnostic tests is effective in terms of accuracy of diagnostic yield and reduction of costs.


Asunto(s)
Técnicas de Diagnóstico Cardiovascular/economía , Costos de Hospital , Unidades Hospitalarias/economía , Síncope/diagnóstico , Adolescente , Niño , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Italia/epidemiología , Tiempo de Internación/economía , Tiempo de Internación/tendencias , Masculino , Estudios Prospectivos , Síncope/economía , Síncope/epidemiología
18.
Europace ; 20(4): 665-672, 2018 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-28407062

RESUMEN

Aims: Recently, voltage gradient mapping of Koch's triangle to find low-voltage connections, or 'voltage bridges', corresponding to the anatomic position of the slow pathway, has been introduced as a method to ablate atrioventricular nodal reentry tachycardia (AVNRT) in children. Thus, we aimed to assess the effectiveness of voltage mapping of Koch's triangle, combined with the search for the slow potential signal in 'low-voltage bridges', to guide cryoablation of AVNRT in children. Methods and results: From June 2015 to May 2016, 35 consecutive paediatric patients (mean age 12.1 ± 4.5 years) underwent 3D-guided cryoablation of AVNRT at our Institution. Fifteen children were enrolled as control group (mean age 14 ± 4 years). A voltage gradient mapping of Koch's triangle was obtained in all patients, showing low-voltage connections in all children with AVNRT but not in controls. Prior to performing cryoablation, we looked for the typical 'hump and spike' electrogram, generally considered to be representative of slow pathway potential within a low-voltage bridge. In all patients the 'hump and spike' electrogram was found inside bridges of low voltage. Focal or high-density linear lesions, extended or not, were delivered guided by low-voltage bridge visualization. Acute success rate was 100%, and no recurrence was reported at a mean follow-up of 8 ± 3 months. Conclusions: Voltage gradient mapping of Koch's triangle, combined with the search for the slow potential signal in low-voltage bridges, is effective in guiding cryoablation of AVNRT in paediatric patients, with a complete acute success rate and no AVNRT recurrences at mid-term follow-up.


Asunto(s)
Nodo Atrioventricular/cirugía , Criocirugía , Técnicas Electrofisiológicas Cardíacas , Taquicardia por Reentrada en el Nodo Atrioventricular/cirugía , Potenciales de Acción , Adolescente , Adulto , Factores de Edad , Nodo Atrioventricular/fisiopatología , Estudios de Casos y Controles , Niño , Preescolar , Criocirugía/efectos adversos , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Valor Predictivo de las Pruebas , Recurrencia , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
19.
Europace ; 20(12): 1966-1973, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-29939256

RESUMEN

Aims: Use of the subcutaneous implantable cardioverter-defibrillator (S-ICD) to prevent sudden cardiac death is increasing. Few data exist on S-ICD in young patients. We reviewed our single-centre experience in order to assess the effectiveness and safety of S-ICD implantation, and to identify potential factors associated with complications. Methods and results: Observational, non-randomized, standard-of-care study on S-ICD implantation/follow-up in young patients with inherited arrhythmias (IA), cardiomyopathies, and congenital heart defects (CHD). Fifteen patients (6 CHD, 8 cardiomyopathies, and 1 IA), median age 15 years (25th-75th centiles, 14-28), 10 of them <18 years, with body mass index (BMI) 22.6 ± 3.4, underwent S-ICD implantation (primary prevention 93%). The first six patients underwent a standard implantation procedure (three surgical incisions), the following nine a two-incision procedure. No intraoperative complications occurred. Over 12 (7-24) months follow-up, two patients received appropriate shocks and one (7%) inappropriate shock. Four patients had device-related complications requiring surgical intervention: three skin erosions at the superior parasternal incision, one pocket infection. A higher risk of complications was seen in patients who underwent standard procedures [hazard ratio (HR) 4.98, 95% confidence interval (CI) 1.53-47.36; P = 0.0482] and those with BMI <20 (HR 9.44, 95% CI 0.95-93.23; P = 0.0169). Conclusion: S-ICD implantation was safe and effective in young patients with low rates of inappropriate shock. However, the risk of device-related complications during follow-up remains substantial in patients with low BMI. To prevent possible complications, a two-incision technique should be preferred.


Asunto(s)
Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Cardioversión Eléctrica/instrumentación , Adolescente , Adulto , Factores de Edad , Índice de Masa Corporal , Niño , Toma de Decisiones Clínicas , Muerte Súbita Cardíaca/etiología , Desfibriladores Implantables/efectos adversos , Cardioversión Eléctrica/efectos adversos , Femenino , Humanos , Masculino , Selección de Paciente , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Ciudad de Roma , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
20.
Pacing Clin Electrophysiol ; 41(9): 1204-1211, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29989185

RESUMEN

BACKGROUND: Alternative right ventricular (RV) sites (RVAPS) have been proposed to prevent or reduce RV pacing-induced left-ventricular (LV) dysfunction. Nonfluoroscopic 3D electroanatomic mapping systems (EAM) have been developed to guide cardiac catheter navigation and reduce fluoroscopy during electrophysiological procedures or pacemaker implantations. AIM: The aim of the study was to compare the results of EAM-guided permanent pacemaker implantation aiming at RVAPS with conventional fluoroscopic-guided implantation in RV apex (RVA) in children and adolescents. METHODS: A prospective, randomized analysis was performed on children/adolescents with complete atrioventricular block (CAVB) who underwent EAM-guided pacemaker and transvenous leads implantation into RVAPS (EAM-RVAPS) or conventional, fluoroscopic-guided implantation into RV apex (RVA). In EAM-RVAPS, a pacing map guided the implantation of ventricular leads in septal sites with narrower QRS. After implantation, LV contractility (ejection fraction [EF], Global Longitudinal Strain [GLS]) and synchrony were evaluated at 1-12 months. RESULTS: Twenty-one pediatric patients with CAVB, with (six patients) or without structural heart diseases, aged 4-16 (median 10.5) years, were divided in two groups: EAM-RVAPS (11 patients, four dual-chamber/DDD, seven single-chamber/VVIR pacemakers) and RVA (10 patients, one DDD/nine VVIR). The two groups did not show significant differences for preoperative parameters. EAM-RVAPS showed: preserved LVEF and synchrony (not significantly different than RVA), significantly lower GLS and radiation doses/exposures, in spite more complex procedures, significantly longer procedure times and narrower paced QRS than RVA. CONCLUSIONS: EAM-guided procedures have been useful to reduce radiation exposure and to localize RVAPS with narrower paced QRS and lower GLS than RVA.


Asunto(s)
Bloqueo Atrioventricular/fisiopatología , Bloqueo Atrioventricular/terapia , Estimulación Cardíaca Artificial/métodos , Ventrículos Cardíacos/fisiopatología , Marcapaso Artificial , Disfunción Ventricular Izquierda/prevención & control , Disfunción Ventricular Izquierda/fisiopatología , Niño , Preescolar , Femenino , Fluoroscopía , Humanos , Masculino , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA