1.
J Thorac Cardiovasc Surg ; 105(3): 520-4, 1993 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8445929

RESUMEN

An implantable, electrically powered pump that will provide tether-free circulatory support is being developed. The blood pump consists of a seamless polyurethane sac within a polysulfone case. Björk-Shiley Monostrut valves provide unidirectional flow. The blood sac is compressed by a pusher plate with a stroke of 1.9 cm and actuated by a brushless direct-current electric motor and motion translator. The current unit is completely sealed, and inductive coupling techniques provide the electrical energy. The system has an implantable electronic control system as well as a battery that provides 30 minutes of operation when the external coil is disconnected. During normal operation, however, the pump is powered by a portable battery pack or by house current. The unit can pump 8.5 L/min at physiologic pressures. Twenty-six animals have had circulatory support for a period of more than 1 week. The average period of pumping was 62 days; the longest was nearly 8 months. Experiments were terminated in 18 animals because of pump-related problems and in 8 because of biologically related problems. Studies to date are very encouraging and suggest that, with further refinement, a reliable 2-year assist pump that will have important clinical application can be developed.


Asunto(s)
Circulación Asistida , Circulación Coronaria , Animales , Circulación Asistida/instrumentación , Ventrículos Cardíacos
2.
Surgery ; 90(2): 137-48, 1981 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-7256534

RESUMEN

Over the last two decades, the implantable artificial heart has evolved from an idea to a device capable of completely supporting the circulation for periods now exceeding 5 months. Although initial animal studies were limited by thromboembolism and device breakage, the usual causes of death in experimental animals are now infection, atrioventricular valve obstruction, elastomer bladder calcification, or inadequate cardiac output because of the relatively rapid growth of the young calves. As a result of the bulky nature of the energy converter and the substantial risk of infection with large diameter percutaneous tubes, clinical use of their air-powered artificial hearts will be limited to patients who are awaiting or being prepared for heart transplantation. Artificial hearts with implanted energy converters are being developed for permanent heart replacement. These devices require well-designed, durable mechanical components and sophisticated control systems. Although initial designs centered around thermal engines powered by a completely implantable nuclear energy source, the excessive cost and potential dangers have shifted the focus away from the nuclear system. Several electrically driven artificial hearts, based on samarium-cobalt magnet brushless direct-current motors, are now undergoing bench testing and will be ready for long-term animal studies within 2 years. This research will culminate with the availability of an "off-the-shelf" electrically powered artificial heart for use in patients with a wide range of nonrepairable forms of end-stage heart disease.


Asunto(s)
Fuentes de Energía Bioeléctrica/normas , Cardiopatías/terapia , Corazón Artificial/normas , Animales , Materiales Biocompatibles/normas , Procedimientos Quirúrgicos Cardíacos , Bovinos , Humanos , Cuidados Posoperatorios , Complicaciones Posoperatorias
3.
J Appl Physiol (1985) ; 84(3): 868-76, 1998 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-9480945

RESUMEN

To obtain a physiological response by a total artificial heart (TAH), while eliminating the hemodynamic abnormalities commonly observed with its use, we proposed the use of a conductance- and arterial pressure-based method (1/R control) to determine TAH cardiac output. In this study, we endeavored to make use of a variable more closely tied to central nervous system (CNS) efferents, systemic conductance, to provide the CNS with more direct control over the output of the TAH. The control equation that calculates the target cardiac output of the TAH was constructed on the basis of measurement of blood pressures and TAH flow. The 1/R control method was tested in TAH-recipient goats with an automatic method by using a microcomputer. In 1/R control animals, the typical TAH pathologies, such as mild arterial hypertension and substantial systemic venous hypertension, did not occur. Cardiac output varied according to daily activity level and exercise in a manner similar to that observed in natural heart goats. These results indicate that we have determined a control method for the TAH that avoids hemodynamic abnormalities exhibited by other TAH control systems and that exhibits physiological responses to exercise and daily activities under the conditions tested. The stability of the control and the complete lack of inappropriate excursions in cardiac output is suggestive of CNS involvement in stabilizing the system.


Asunto(s)
Presión Sanguínea/fisiología , Corazón Artificial , Conducción Nerviosa/fisiología , Animales , Sistema Nervioso Autónomo/fisiología , Gasto Cardíaco/fisiología , Femenino , Cabras , Hemodinámica/fisiología , Plasticidad Neuronal/fisiología , Perfusión , Volumen Sistólico/fisiología , Resistencia Vascular/fisiología
4.
Ann Thorac Surg ; 47(1): 172-8, 1989 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-2912392

RESUMEN

Pneumatic total artificial heats, although demonstrating utility as temporary mechanical circulatory support devices, have not demonstrated a great deal of promise as permanent cardiac replacements. The increasing number of patients who would be candidates for total heart replacement suggests a large role for a permanent implantable total artificial heart. To that end, the Pennsylvania State University is developing an electric motor-driven total artificial heart; the results with implants in calves are encouraging. In this device, a roller-screw mechanism is used to translate the rotation of a brushless direct-current motor into rectilinear motion of a pusher-plate assembly, which in turn empties the blood sacs. The total artificial heart of the future will function under automatic control without percutaneous leads, and this should provide the patient with a nearly normal life-style. Although further experimental efforts are necessary to prepare the device for clinical trials, the technology to provide a safe and reliable electric blood-pump system is at hand.


Asunto(s)
Corazón Artificial , Animales , Presión Sanguínea , Gasto Cardíaco , Procedimientos Quirúrgicos Cardíacos , Bovinos , Suministros de Energía Eléctrica , Electrónica Médica/instrumentación , Diseño de Equipo , Predicción , Humanos , Estilo de Vida , Monitoreo Fisiológico , Factores de Tiempo
5.
Ann Thorac Surg ; 71(3 Suppl): S150-5; discussion S183-4, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11265851

RESUMEN

BACKGROUND: Two modifications of the surgical implantation protocol for the Penn State Total Artificial Heart (ETAH) were evaluated: Phrenic nerve ischemia was prevented by minimizing dissection and traction; and hemostasis was augmented and ETAH cuff anastomoses reinforced by using fibrin glue. METHODS: Thirteen Holstein calves underwent orthotopic surgical implantation of the Penn State ETAH between February 1998 and August 2000. Mean hemodynamic and laboratory chemistry variables from the first postoperative week were compared between calves receiving the original (n = 7) and modified (n = 6) protocol. RESULTS: Calves assigned to the modified protocol displayed an improvement in the Po2/FiO2 ratio compared to original (419.4 +/- 17.5 vs 336.3 +/- 35.4, respectively; p = 0.05). All additional parameters were equivalent between groups. The percent survival of animals receiving the modified protocol at 2, 4, and 12 weeks was higher than that of animals that underwent the original protocol. Original-protocol calf deaths consisting of hemothorax (n = 3), and respiratory failure (n = 1) were prevented in the modified protocol. CONCLUSIONS: Our results suggest that manipulations in surgical protocol may promote increased survival in calves implanted with the Penn State ETAH.


Asunto(s)
Corazón Artificial , Implantación de Prótesis/métodos , Animales , Bovinos , Causas de Muerte , Corazón Artificial/efectos adversos , Hemodinámica , Complicaciones Posoperatorias/epidemiología , Diseño de Prótesis , Implantación de Prótesis/efectos adversos , Tasa de Supervivencia
6.
Ann Thorac Surg ; 71(3 Suppl): S156-61; discussion S183-4, 2001 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-11265852

RESUMEN

Management of patients with end-stage cardiac disease remains a vexing problem. Limitations in medical management and a fixed supply of donor organs for cardiac transplant have a continued impact on this growing population of patients. Mechanical circulatory support has proved very successful as a means of bridging patients to cardiac transplant when all medical options have been exhausted. The development of a chronic system of circulatory support has been underway at the Pennsylvania State University for nearly 30 years. These efforts have been recently merged with the industrial partnership with Arrow International toward the development of the LionHeart LVD-2000 (Arrow International, Reading, PA) completely implanted left ventricular support system. We present an overview of the system, details of implantation, a review of preclinical studies, and a synopsis of the first European implants. Early results have demonstrated the system to be safe, effective, and reliable. Transcutaneous energy transmission and the compliance chamber have been validated.


Asunto(s)
Insuficiencia Cardíaca/cirugía , Corazón Auxiliar , Animales , Diseño de Equipo , Humanos , Implantación de Prótesis/métodos , Factores de Tiempo
7.
Surg Endosc ; 16(2): 280-5, 2002 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-11967678

RESUMEN

BACKGROUND: In the area of instrument evaluation, one aspect that still requires objective assessment is the dynamics of instrument maneuver and exchange. If we could gain a better understanding of these phenomena, we could improve the design of the instruments themselves. METHODS: A total of 29 laparoscopic procedures were videotaped and reviewed using time motion analysis. Instrument multifunctionality was determined using a standardized list of laparoscopic maneuvers. State transition diagrams were utilized to document the sequence of instrument exchanges. RESULTS: The curved dissector, atraumatic grasper, and cautery scissors were identified as the most multifunctional instruments; each was able to perform five distinct maneuvers. Instrument sequences were found to consist of a three-part dissect --> clip --> cut cycle and a two-part dissect --> suction cycle of instrument exchange. CONCLUSION: This study demonstrated that laparoscopic instruments are often used to perform a variety of maneuvers in addition to their primary function. Furthermore, there are common patterns in instrument exchange that provide a potential source of design parameters for improved surgical efficiency.


Asunto(s)
Laparoscopios , Laparoscopía/métodos , Análisis y Desempeño de Tareas , Humanos , Grabación de Cinta de Video
8.
IEEE Trans Biomed Eng ; 37(2): 138-45, 1990 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-2312138

RESUMEN

Permanent circulatory support systems are required for patients in whom myocardial damage is irreversible and cardiac transplantation is not possible. Two systems are described which provide long term circulatory support: the left ventricular assist system and the total artificial heart. These systems are based on the design of a pusher plate actuated blood pump, driven by a small brushless dc electric motor and rollerscrew driver. An implantable motor controller maintains suitable physiologic flow rates for both systems and controls left-right balance in the total artificial heart. Other parts of the system include an intra-thoracic compliance chamber, transcutaneous energy and data transmission system, and internal and external batteries.


Asunto(s)
Corazón Artificial , Corazón Auxiliar , Animales , Bovinos , Diseño de Equipo , Falla de Equipo , Humanos
9.
J Periodontol ; 53(2): 93-5, 1982 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-7038088

RESUMEN

The effect of root planing and curettage on the crevicular depth and periodontal attachment at the distal of mandibular second molars following removal of adjacent impacted or partially erupted third molars was evaluated in 18 patients, between the ages of 18 and 25, presenting with similar bilateral impactions. No significant difference was demonstrated in the crevicular depths and attachment levels between the curetted, root planed side, and the untreated controls. Thus, any benefits derived by root planing and curettage of mandibular second molars immediately following removal of adjacent impacted third molars are minimal. The best means of preserving periodontal attachment on mandibular second molars may be the removal of third molars at an early stage of tooth development.


Asunto(s)
Inserción Epitelial/anatomía & histología , Encía/anatomía & histología , Tercer Molar/cirugía , Diente Molar , Periodoncio/anatomía & histología , Adolescente , Adulto , Raspado Dental , Humanos , Curetaje Subgingival , Factores de Tiempo , Extracción Dental , Raíz del Diente/cirugía , Diente Impactado/cirugía
10.
J Periodontol ; 55(5): 273-7, 1984 May.
Artículo en Inglés | MEDLINE | ID: mdl-6376756

RESUMEN

Initial pilot studies using tricalcium phosphate ceramic placed into human periodontal osseous defects demonstrated osseous repair. Therefore, further evaluation of this material was undertaken on 17 carefully selected patients with 1-wall, 2-wall, crestal and furcation defects using standardized preoperative and postoperative radiographs, clinical measurements and clinical photographs. Inverse bevel, full-thickness flaps were raised, the areas debrided, root surfaces planed with ultrasonic and hand instrumentation, osseous penetrations made with curet point and the flaps sutured after the defects were filled. Eighteen-month reentry surgical procedures were performed on 10 of the 17 patients, with a resultant average of 2.8 mm of new bone. Controls were not used in this study since a protocol describing a sham procedure with other than 3-wall osseous defects was not acceptable in 1973 to the Clinical Human Use Committee. Although the tricalcium phosphate ceramic material was not found to be totally predictable in this study, it may nevertheless become a useful graft material because of its potential for osseous repair in combination with its availability, host acceptability, ease of manipulation and storage advantages.


Asunto(s)
Alveoloplastia/métodos , Materiales Biocompatibles , Fosfatos de Calcio , Enfermedades Periodontales/cirugía , Prótesis e Implantes , Raspado Dental/métodos , Estudios de Evaluación como Asunto , Humanos , Osteogénesis , Enfermedades Periodontales/diagnóstico por imagen , Radiografía , Colgajos Quirúrgicos , Raíz del Diente/cirugía
11.
J Periodontol ; 55(4): 203-12, 1984 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-6585538

RESUMEN

Facial recession defects were created on maxillary canine teeth of six Macaca irus monkeys and left untreated and exposed to oral fluids for 6 to 12 weeks. Notches were placed in the exposed root surfaces at the level of the free gingival margins. Following root planing with the addition of topical citric acid application on experimental surfaces, pedicle flaps were coronally positioned over the previously exposed roots. After euthanasia, block sections representing postsurgical time periods of 0, 3, 7, 14, 21, 28 and 42 days were secured and tissues were processed for histologic evaluation. All citric acid-treated surfaces exhibited new connective tissue attachment of pedicle flaps to previously exposed areas by 14 days with transmission electron micrographs confirming beginning cementum deposition. In contrast, controls demonstrated epithelial migration to, or apical to, reference notches. Although the total number of samples available for statistical comparison was small, a two-tailed t test for correlated samples showed citric acid application did not result in enhanced clinical root coverage, but did result in significantly greater amounts of new connective tissue attachment (P less than 0.05, df = 3). Pedicle flap healing against teeth with devital pulps was identical to that seen in teeth with vital pulps, while citric acid application to root-planed surfaces of vital teeth had no observable effect upon pulpal tissues.


Asunto(s)
Citratos/farmacología , Encía/anatomía & histología , Enfermedades de las Encías/cirugía , Colgajos Quirúrgicos , Raíz del Diente/anatomía & histología , Animales , Citratos/administración & dosificación , Ácido Cítrico , Cemento Dental/anatomía & histología , Epitelio/anatomía & histología , Epitelio/fisiología , Estudios de Evaluación como Asunto , Femenino , Encía/fisiología , Macaca fascicularis , Masculino , Factores de Tiempo , Raíz del Diente/fisiología , Raíz del Diente/cirugía , Cicatrización de Heridas
12.
ASAIO J ; 44(5): M613-8, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-9804508

RESUMEN

In long-term studies testing the Penn State Total Artificial Heart involving 30 calves, seven calves died of pulmonary complications within 2 weeks after receiving the implant (Group 1 [G1]) and seven calves survived from 2 weeks to 3 months without infection (Group 2 [G2]). Comparative studies were performed using multiple variables: cardiopulmonary bypass (CPB) time, cardiac index, central venous pressure, leukocyte count, hematocrit, total protein, albumin, serum glutamic oxaloacetic transaminase (GOT), creatinine, water balance, and transfused blood volume. In G1, CPB time was longer than in G2 (182 +/- 19 vs 156 +/- 17 minutes, respectively, p = 0.018). Postoperative minimum total protein and albumin in G1 were lower than those in G2 (56.5% +/- 6.0% and 59.0% +/- 5.5% of preoperative values vs 68.4% +/- 8.5% and 67.8% +/- 6.1%, respectively, p = 0.011 and 0.015). Water balance in G2 was more positive than in G1 (11.7 +/- 6.8 vs 1.4 +/- 8.3 L, respectively, p = 0.020). Other variables showed no significant differences. Microscopic findings of the lung in G1 were congestion, hemorrhage, aggregation of neutrophils, and proteinaceous material within the interstitial tissues and alveoli.


Asunto(s)
Corazón Artificial/efectos adversos , Enfermedades Pulmonares/etiología , Animales , Bovinos , Enfermedades Pulmonares/patología , Estudios Retrospectivos
13.
ASAIO J ; 38(3): M707-12, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1457954

RESUMEN

An electric motor driven orthotopic artificial heart was implanted in a 110 kg female Holstein calf as part of a series of 12 such implants intended to demonstrate the in vivo durability and compatibility of the device. The device uses pusher plates set into motion by a reversing brushless DC motor and roller screw to alternately eject two cylindrical sac type blood pumps. The pumps use Bjork-Shiley Delrindisc convexo-concave or monostrut valves. The left pump provides an 88-90 ml dynamic stroke volume. Woven Dacron grafts and polyurethane coated Dacron/Lycra cuffs are used to attach the device to the major arteries and atria, respectively. A polyurethane conduit and anchoring skin button bring motor wires percutaneously to an extracorporeal controller. The controller provides balanced cardiac output sensitive to atrial or aortic pressures, without operator intervention. The system is hermetically sealed and uses a simple compliance sac to maintain thoracic pressure between the pumps. The calf recovered uneventfully from surgery and thrived thereafter. She was killed on the 388th post-operative day because of worsening cardiac insufficiency. The previous three operative survivors in this series lived 131, 134, and 204 days. These results indicate the device's good potential for durability and body compatibility.


Asunto(s)
Corazón Artificial , Animales , Bovinos , Electrónica Médica , Estudios de Evaluación como Asunto , Femenino , Corazón Artificial/efectos adversos , Hemodinámica , Diseño de Prótesis , Factores de Tiempo , Equilibrio Hidroelectrolítico
14.
ASAIO J ; 39(3): M415-8, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8268569

RESUMEN

To eliminate the need for a separate parapleural compliance chamber, we are currently investigating the feasibility of an annular compliance chamber. This chamber wraps around the energy converter and fits between the blood pumps of the Pennsylvania State University electric total artificial heart. For the 100 cc total artificial heart, the compliance chamber volume is 76 ml and the tissue contacting surface area is approximately 85 cm2. The chamber is made of Dacron velour covered segmented polyether polyurethane urea. The annular compliance chamber was evaluated in vitro by comparing pump balance control performance against that obtained with an open vent. In the CVP range of 5-12 mmHg, LAP was maintained within 1 mmHg of the values obtained with a vent. Studies continue to determine the range of volumes over which the chamber is effective, differences in rates of diffusion, and performance during changes in barometric pressure.


Asunto(s)
Corazón Artificial , Hemodinámica/fisiología , Presión Atmosférica , Presión Sanguínea/fisiología , Gasto Cardíaco/fisiología , Adaptabilidad , Suministros de Energía Eléctrica , Diseño de Equipo , Humanos
15.
ASAIO J ; 39(3): M427-32, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8268572

RESUMEN

A completely implantable left ventricular assist device (LVAD) designed for permanent circulatory support has recently been tested in animals without the use of percutaneous leads, using transcutaneous energy transmission and wireless telemetry. The LVAD consists of a brushless DC motor and rollerscrew energy converter, a pusher plate actuated blood pump with a seamless segmented polyurethane blood sac, Bjork-Shiley Delrin disk monostrut valves, an implanted compliance chamber, an implanted electronic controller and battery, and a transcutaneous energy transmission system. The blood pump/energy converter assembly weighs 565 g and displaces 295 cc. The dynamic stroke volume is 60 ml, and the maximum output is 9 L/min. Pump output is automatically controlled to maintain full stroke volume as preload varies. Hall effect sensors for detecting rotary position of the motor are the only sensors used. Six bovine implants were performed, with durations of 84, 208, 244, 130, 70 (ongoing), and 15 (ongoing) days. Four animals used two-way telemetry, whereas the remaining two used one-way (outgoing) telemetry. These first chronic in vivo tests with the Penn State completely implanted LVAD system have demonstrated that it is a feasible solution to long-term ventricular support.


Asunto(s)
Corazón Artificial , Corazón Auxiliar , Animales , Bilirrubina/sangre , Velocidad del Flujo Sanguíneo/fisiología , Nitrógeno de la Urea Sanguínea , Bovinos , Creatinina/sangre , Diseño de Equipo , Falla de Equipo , Hemodinámica/fisiología , Hemoglobinometría , Humanos , Procesamiento de Señales Asistido por Computador/instrumentación , Telemetría/instrumentación
16.
ASAIO J ; 46(6): 779-82, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-11110281

RESUMEN

The development of a completely implanted total artificial heart at our institution has progressed to successful in vivo and in vitro testing of a device that is nearing clinical testing. This system consists of a 70 cc stroke volume pump originally designed to be used in men of average stature. Implantation of this system remains limited by patient size; hence, many women and adolescent patients will likely be precluded from support because of their smaller stature. A system similar in design, but with a 50 cc stroke volume pump has been developed. The first in vivo study of this device has been undertaken. A calf was supported for 33 days. The animal was extubated and ambulatory within the first 6 hours of implantation, and remained healthy until the thirty-third postoperative day when it suffered an embolic neurologic event. The pump and operating system worked flawlessly throughout the period of support. Further in vivo and in vitro testing will be undertaken. Development of a scaled down total artificial heart system expands this type of circulatory support to those critically ill patients previously deemed poor candidates because of their smaller body habitus.


Asunto(s)
Corazón Artificial , Adolescente , Adulto , Animales , Constitución Corporal , Bovinos , Electrónica Médica/instrumentación , Diseño de Equipo , Femenino , Humanos , Masculino , Volumen Sistólico
17.
ASAIO J ; 42(5): M342-6, 1996.
Artículo en Inglés | MEDLINE | ID: mdl-8944903

RESUMEN

The total artificial heart under development by the Pennsylvania State University and 3M Health Care has undergone a number of design improvements to improve reliability, manufacturability, implantability, and performance. These improvements are nearing completion in preparation for formal durability testing. The redesigned implanted electronics canister, consisting of a welded titanium shell with hermetic connectors, contains the control, telemetry, and energy transmission electronics, as well as a 9 cell, 800 mAhr Ni-Cd battery pack. Functional changes include a reduction in the battery recharge time from 14 hours to 4 hours, and a new inductive telemetry system. The energy transmission system operating frequency has been increased from 160 kHz to 200 kHz. Electromagnetic interference filters and a more efficient control mode have also been implemented. The energy converter has been modified to incorporate a new motor with integral Hall effect position sensors, and new cable, and compliance chamber conduit fittings. High flex life cable is now used for the motor and coil cables. Two prototype durability mock circulatory loops have been built and are being tested. Substantial progress has been made in the completion of manufacturing documentation, and in the implementation of a quality system.


Asunto(s)
Corazón Artificial , Animales , Bovinos , Electrónica Médica/instrumentación , Estudios de Evaluación como Asunto , Humanos , Diseño de Prótesis , Telemetría/instrumentación
18.
ASAIO J ; 39(3): M177-84, 1993.
Artículo en Inglés | MEDLINE | ID: mdl-8268524

RESUMEN

The authors performed 14 implants of a completely implanted total artificial heart (TAH) system in calves. The system consisted of a dual pusher plate rollerscrew energy converter, two sac type blood pumps, an implanted electronic control and battery package, and a transcutaneous energy transmission system. Ten of the implants included a percutaneous lead for monitoring of the implant; the remainder made use of wireless two way telemetry between the implant and the outside. Three animals survived the perioperative period. These calves survived for 98 to 118 days, and one was still alive at 150 days. Causes for termination of the 98 and 118 day cases were abdominal pocket sepsis originating at a monitoring line, and systemic sepsis acquired perioperatively. Death or termination in the shorter cases was mainly due to respiratory complications or bleeding. The TAH system proved capable of providing adequate cardiac outputs at modest atrial pressures. Wireless monitoring and wireless intervention for weaning from cardiopulmonary bypass were readily achieved. All organ systems functioned normally in the presence of the device. Once recovery from implantation in these very young animals was achieved, the system proved its ability to reliably support these animals until body mass exceeded its cardiac output capabilities.


Asunto(s)
Corazón Artificial , Animales , Nitrógeno de la Urea Sanguínea , Gasto Cardíaco/fisiología , Bovinos , Creatinina/sangre , Suministros de Energía Eléctrica , Hemólisis/fisiología , Pruebas de Función Hepática , Diseño de Prótesis , Falla de Prótesis , Procesamiento de Señales Asistido por Computador/instrumentación , Telemetría/instrumentación
19.
ASAIO J ; 45(3): 189-93, 1999.
Artículo en Inglés | MEDLINE | ID: mdl-10360721

RESUMEN

Total Artificial Heart (TAH) development at Penn State University and 3M Health Care has progressed from design improvements and manufacturing documentation to in vitro and in vivo testing to characterize the system's hemodynamic response and energetic performance. The TAH system is completely implantable and intended for use as an alternative to transplantation. It includes a dual pusher plate pump and rollerscrew actuator, welded electronics and battery assembly, transcutaneous energy transmission system, telemetry, and a compliance chamber. In vitro testing was conducted on a Penn State mock circulatory loop with glycerol/water solution at body temperature. Tests were performed to characterize the preload and afterload response, left atrial pressure control, and power consumption. A sensitive preload response was demonstrated with left atrial pressure safely maintained at less than 15 mm Hg for flow rates up to 7.5 L/min. Variations in aortic pressure and pulmonary vascular resistance were found to have minimal effects on the preload sensitivity and left atrial pressure control. In vivo testing of the completely implanted system in its final configuration was carried out in two acute studies using implanted temperature sensors mounted on the electronics, motor, and energy transmission coil in contact with adjacent tissue. The mean temperature at the device-tissue interface was less than 4 degrees C above core temperature.


Asunto(s)
Corazón Artificial , Hemodinámica , Ensayo de Materiales , Animales , Aorta/fisiología , Función Atrial , Bovinos , Técnicas In Vitro , Presión Esfenoidal Pulmonar , Flujo Pulsátil , Telemetría , Temperatura
20.
J Biomater Appl ; 14(4): 349-66, 2000 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-10794507

RESUMEN

In the present study, we investigate the in vivo and in vitro stability of modified poly(urethaneurea) (BioSpan MS/0.4) blood sacs. Blood sacs were utilized primarily in left ventricular assist devices that were implanted in calves for times ranging from 5 to 160 days. Cyclic testing in vitro was also conducted on similar sacs. Various analytical methods were employed to characterize the sacs after in vivo or in vitro service and corresponding retained "control" sacs. These methods included ATR-FTIR spectroscopy, scanning electron microscopy and gel permeation chromatography. In general, the characteristics of implanted and in vitro cycled sacs were similar to their control sacs. Thermal and microtensile properties were unchanged after testing. The same was true for the ATR-FTIR spectra, indicating relative chemical stability for the time frames explored here. The only significant changes occurred in molecular weight and gross surface morphology. A modest increase in weight average molecular weight was observed for most implanted blood sacs, indicating some type of chain extension or branching reaction in vivo. Although the surface morphologies of implanted blood sacs were often similar to their control sacs, we sometimes observed limited pitting on the nonblood contacting surfaces in regions of the sac that experience maximum bending during service.


Asunto(s)
Materiales Biocompatibles/química , Corazón Auxiliar , Polímeros/química , Poliuretanos/química , Animales , Biodegradación Ambiental , Rastreo Diferencial de Calorimetría , Bovinos , Cromatografía en Gel , Microscopía Electrónica de Rastreo , Peso Molecular , Prótesis e Implantes , Espectroscopía Infrarroja por Transformada de Fourier , Propiedades de Superficie , Resistencia a la Tracción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA