Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiothorac Vasc Anesth ; 34(8): 2060-2068, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32127264

RESUMEN

OBJECTIVES: To evaluate whether a preoperative diagnosis of atrial septal defect (ASD) or patent foramen ovale (PFO) is associated with perioperative stroke in noncardiac surgery and their outcomes. DESIGN: Retrospective cohort analysis. SETTING: United States hospitals. PARTICIPANTS: Adults patients (≥18 years old) who underwent major noncardiac surgery from 2010 to 2015 were identified using the Healthcare Cost and Utilization Project's National Readmission Database. INTERVENTIONS: Preoperative diagnosis of ASD or patent foramen ovale. MEASUREMENTS AND MAIN RESULTS: Among the 19,659,161 hospitalizations for major noncardiac surgery analyzed, 12,248 (0.06%) had a preoperative diagnosis of ASD/PFO. Perioperative ischemic stroke occurred in 723 (5.9%) of patients with ASD/PFO and 373,291 (0.02%) of those without ASD/PFO (adjusted odds ratio [aOR], 16.7; 95% confidence interval [CI]: 13.9-20.0). Amongst the different types of noncardiac surgeries, obstetric, endocrine, and skin and burn surgery were associated with higher risk of stroke in patients with pre-existing ASD/PFO. Moreover, patients with ASD/PFO also had an increased in-hospital mortality (aOR, 4.6, 95% CI: 3.6-6.0), 30-day readmission (aOR, 1.2, 95% CI: 1.04-1.38), and 30-day stroke (aOR, 7.2, 95% CI: 3.1-16.6). After adjusting for atrial fibrillation, ischemic stroke remained significantly high in the ASD/PFO group (aOR: 23.7, 95%CI 19.4-28.9), as well as in-hospital mortality (aOR: 5.6, 95% CI 4.1-7.7), 30-day readmission (aOR: 1.19, 95%CI 1.0-1.4), and 30-day stroke (aOR: 9.3, 95% CI 3.7-23.6). CONCLUSIONS: Among adult patients undergoing major noncardiac surgery, pre-existing ASD/PFO is associated with increased risk of perioperative ischemic stroke, in-hospital mortality, 30-day stroke, and 30-day readmission after surgery.


Asunto(s)
Isquemia Encefálica , Foramen Oval Permeable , Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Adolescente , Adulto , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/epidemiología , Isquemia Encefálica/etiología , Foramen Oval Permeable/complicaciones , Foramen Oval Permeable/diagnóstico , Foramen Oval Permeable/epidemiología , Humanos , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Estados Unidos
4.
J Invasive Cardiol ; 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38754082

RESUMEN

The combined procedure of catheter ablation and percutaneous left atrial appendage occlusion for patients with atrial fibrillation has been shown to be safe and feasible using radiofrequency energy or cryoballoon.

5.
J Invasive Cardiol ; 35(3): E128-E135, 2023 03.
Artículo en Inglés | MEDLINE | ID: mdl-36645333

RESUMEN

BACKGROUND: Severe coronary artery calcification (CAC) remains challenging during percutaneous coronary intervention (PCI) and often requires 1 or more advanced calcium modification tools. OBJECTIVES: We describe the combination use of rotational (RA) or orbital atherectomy (OA), with intravascular lithotripsy (IVL), termed rotatripsy and orbital-tripsy, respectively, for modifying CAC prior to stent implantation during PCI. METHODS: We performed a retrospective analysis of patients treated with rotatripsy or orbital-tripsy at our center between July 2019 and March 2022. The primary efficacy endpoint was procedural success (successful stent implantation, <30% residual stenosis visually, Thrombolysis in Myocardial Infarction 3 flow; absence of types C to F dissection/perforation or loss of side branch ≥2.0mm visually) without in-hospital major adverse cardiovascular event (MACE, defined as cardiovascular death, myocardial infarction [MI], target-vessel revascularization). RESULTS: A total of 25 patients (14 rotatripsy and 11 orbital-tripsy) were included in our study. The mean age was 72.2 ± 7.6 years and 76% were men. PCI was guided by intravascular imaging in 24 patients (96%). All cases were treated with either RA or OA before utilization of IVL. Procedural success was achieved in 22 cases (88%) with 1 sidebranch loss without periprocedural MI (4%) and 2 in-patient deaths (8%) unrelated to the procedure (1 intracerebral hemorrhage and 1 cardiac arrest). CONCLUSION: We describe efficacious use of both rotatripsy and orbital-tripsy to modify severe CAC during PCI in a real-world setting. Intravascular imaging can guide appropriate use of these devices to complement each other to modify severe CAC to achieve optimal outcomes.


Asunto(s)
Aterectomía Coronaria , Enfermedad de la Arteria Coronaria , Litotricia , Infarto del Miocardio , Intervención Coronaria Percutánea , Calcificación Vascular , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Intervención Coronaria Percutánea/métodos , Aterectomía Coronaria/métodos , Calcio , Estudios Retrospectivos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Infarto del Miocardio/etiología , Aterectomía , Calcificación Vascular/diagnóstico , Calcificación Vascular/cirugía , Angiografía Coronaria/métodos
6.
Cardiovasc Revasc Med ; 45: 44-50, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35882600

RESUMEN

INTRODUCTION: Acute MR due to mechanical mitral valve (MV) complications frequently results in cardiogenic shock and requires emergency surgical intervention. There was limited evidence for alternative treatment like MitraClip for patients at prohibitive surgical risk. We aimed to study the technical features and outcomes of emergency transcatheter edge-to-edge repair (TEER) using the MitraClip system for patients with cardiogenic shock (CS) secondary to acute mitral regurgitation (MR) and mechanical MV complication. MATERIAL AND METHODS: We performed institutional review and systemic literature review to identify all TEER for CS patients due to acute mitral regurgitation and mechanical MV complication. Clinical endpoints included device success rate assessed at the end of procedure, ability to wean off MCS, all-cause and cardiovascular mortality at 30-day. RESULTS: Eight patients were identified from institutional review. Detail anatomical analysis found that patients with mechanical MV complications related to myocardial infarction had a lower transseptal height achieved during MitraClip (3.6 ± 0.1 cm vs 4.3 ± 0.3 cm, p = 0.03) than those not related. Pooled analysis for cases from institutional review (n = 8) and systemic literature review (n = 16) was performed. The device success rate was 68.8 %. Seventy-five percent (n = 18) cases required mechanical circulatory support (MCS), and 94.4 % were able to wean off MCS. At 30-day, the cardiovascular mortality was 4.5 % and the all-cause mortality was 9.1 %. CONCLUSIONS: In CS patients due to acute MR and mechanical MV complications, TEER with/without MCS was feasible with a reasonable device success rate.


Asunto(s)
Choque Cardiogénico , Humanos , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/etiología , Choque Cardiogénico/terapia
7.
Am J Cardiovasc Dis ; 11(5): 679-687, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34849300

RESUMEN

BACKGROUND: The anti-thrombotic strategy for patients with atrial fibrillation (AF) who have undergone percutaneous coronary intervention (PCI) for coronary artery disease (CAD) is a common and difficult challenge. This pilot study aimed to assess the feasibility and safety of "one-stop" left atrial appendage closure (LAAC) combined with PCI as an alternative stroke prophylaxis strategy. METHODS: From March 2017 to October 2019, AF patients with elevated bleeding risk and significant stable CAD requiring PCI were recruited to undergo LAAC as alternative stroke prophylaxis in Fuwai Hospital, Beijing, China. LAAC was performed either in the same setting with PCI (i.e. "one-stop" LAAC/PCI), or as staged procedure after PCI. Dual antiplatelet therapy was given for all patients after LAAC. Peri-procedural and intermediate-term clinical outcomes were assessed through hospital clinical records review and standardized telephone interviews. RESULTS: A total of 24 patients were recruited including 13 (54.2%) underwent stage procedure and 11 (45.8%) underwent "one-stop" procedure respectively. The mean CHA2DS2-VASc and HAS-BLED scores were 4.5±1.4 and 3 (IQR 3,4) respectively. Six patients (46.1%) in the staged procedure cohort were treated with triple anti-thrombotic following PCI, with 2 developed minor bleeding before LAAC. One patient ("one-stop" cohort) had gastrointestinal bleeding 1 day after procedure. Otherwise, there was no device related complication or peri-procedural stroke/myocardial infarction. After a mean 19±5.4 months follow-up, there was no death, myocardial infarction, stroke and systemic embolization detected. CONCLUSIONS: In this pilot study, "one-stop" LAAC with PCI was shown to be efficacious with no stroke, MI, VARC-2 major bleeding or CV death reported over a mean follow-up of 19 months, and safe with no major peri-procedural bleeding or device related complications.

8.
Cardiovasc Revasc Med ; 27: 7-13, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-32741589

RESUMEN

BACKGROUND: Detailed procedural analysis and long-term data is limited for coronary protection (CP) during transcatheter aortic valve replacement (TAVR) for patients with high anatomical risk for coronary occlusion (CO). We aim to assess the procedural and mid-term outcomes of CP during TAVR. METHODS: We retrospectively analyzed patients who underwent TAVR at Henry Ford Hospital, USA from January 2015 to August 2019 and identified those considered at risk of CO and underwent pre-emptive CP with or without subsequent "chimney" stenting (i.e. coronary stenting with intentional protrusion into the aorta). Procedural features, immediate and mid-term clinical outcomes were reviewed. RESULTS: Twenty-five out of 1166 (2.1%) patients underwent TAVR with CP, including 10 (40%) valve-in-valve procedures. Twenty-eight coronary arteries (Left: n = 11, Right: n = 11; Left + Right: n = 3) were protected. Eleven coronaries (39.3%) were electively "chimney"-stented due to angiographic evidence of coronary impingement (63.6%), tactile resistance while withdrawing stent (27.3%) and electrocardiogram change (9.1%). Twenty-four patients (24/25, 96%) had successful TAVR without CO. Procedure-related complications included stent-balloon entrapment (n = 1), stent entrapment (n = 1) and occlusive distal stent edge dissection (n = 1). After a mean follow-up of 19.1 months, there was 1 cardiac death but no target vessel re-intervention or myocardial infarction. CONCLUSIONS: Our study found that angiographic evidence of coronary impingement (63.6%) was the most common reason for stent deployment during TAVR with CP. The mid-term clinical outcome of CP with TAVR was favorable.


Asunto(s)
Estenosis de la Válvula Aórtica , Oclusión Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/cirugía , Humanos , Estudios Retrospectivos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
9.
J Am Heart Assoc ; 10(17): e020615, 2021 09 07.
Artículo en Inglés | MEDLINE | ID: mdl-34398676

RESUMEN

Background Transesophageal echocardiogram is currently the standard preprocedural imaging for left atrial appendage occlusion. This study aimed to assess the additive value of preprocedural computed tomography (CT) planning versus stand-alone transesophageal echocardiogram imaging guidance to left atrial appendage occlusion. Methods and Results We retrospectively reviewed 485 Watchman implantations at a single center to compare the outcomes of using additional CT preprocedural planning (n=328, 67.6%) versus stand-alone transesophageal echocardiogram guidance (n=157, 32.4%) for left atrial appendage occlusion. The primary end point was the rate of successful device implantation without major peri-device leak (>5 mm). Secondary end points included major adverse events, total procedural time, delivery sheath and devices used, risk of major peri-device leak and device-related thrombus at follow-up imaging. A single/anterior-curve delivery sheath was used more commonly in those who underwent CT imaging (35.9% versus 18.8%; P<0.001). Additional preprocedural CT planning was associated with a significantly higher successful device implantation rate (98.5% versus 94.9%; P=0.02), a shorter procedural time (median, 45.5 minutes versus 51.0 minutes; P=0.03) and a less frequent change of device size (5.6% versus 12.1%; P=0.01), particularly device upsize (4% versus 9.4%; P=0.02). However, there was no significant difference in the risk of major adverse events (2.1% versus 1.9%; P=0.87). Only 1 significant peri-device leak (0.2%) and 5 device-related thrombi were detected in follow-up (1.2%) with no intergroup difference. Conclusions Additional preprocedural planning using CT in Watchman implantation was associated with a higher successful device implantation rate, a shorter total procedural time, and a less frequent change of device sizes.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Ecocardiografía Transesofágica , Trombosis , Tomografía Computarizada por Rayos X , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Cateterismo Cardíaco , Humanos , Estudios Retrospectivos , Trombosis/diagnóstico por imagen , Trombosis/etiología , Resultado del Tratamiento
10.
Circ Cardiovasc Interv ; 14(11): e009374, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34784236

RESUMEN

BACKGROUND: Women have a higher rate of adverse events after mitral valve surgery. We sought to evaluate whether outcomes after transcatheter edge-to-edge repair intervention by sex have similar trends to mitral valve surgery. METHODS: The primary outcome was 1-year major adverse events defined as a composite of all-cause mortality, stroke, and any bleeding in the overall study cohort. Patients who underwent transcatheter edge-to-edge repair for mitral regurgitation with the MitraClip system in the Society of Thoracic Surgery/American College of Cardiology Transcatheter Valve Therapy registry were evaluated. Linked administrative claims from the Centers for Medicare and Medicaid Services were used to evaluate 1-year clinical outcomes. Associations between sex and outcomes were evaluated using a multivariable logistic regression model for in-hospital outcomes and Cox model for 1-year outcomes. RESULTS: From November 2013 to March 2017, 5295 patients, 47.6% (n=2523) of whom were female, underwent transcatheter edge-to-edge repair. Females were less likely to have >1 clip implanted (P<0.001) and had a lower adjusted odds ratio of device success (adjusted odds ratio, 0.78 [95% CI, 0.67-0.90]), driven by lower odds of residual mitral gradient <5 mm Hg (adjusted odds ratio, 0.54 [CI, 0.46-0.63]) when compared with males. At 1-year follow-up, the primary outcome did not differ by sex. Female sex was associated with lower adjusted 1-year risk of all-cause mortality (adjusted hazard ratio, 0.80 [CI, 0.68-0.94]), but the adjusted 1-year risk of stroke and any bleeding did not differ by sex. CONCLUSIONS: No difference in composite outcome of all-cause mortality, stroke, and any bleeding was observed between females and males. Adjusted 1-year all-cause mortality was lower in females compared with males.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Anciano , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Medicare , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Sistema de Registros , Resultado del Tratamiento , Estados Unidos/epidemiología
11.
Korean Circ J ; 51(7): 626-638, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34227275

RESUMEN

BACKGROUND AND OBJECTIVES: Prior studies have shown that stroke patients treated with percutaneous left atrial appendage occlusion (LAAO) for non-valvular atrial fibrillation (NVAF) experience better outcomes than similar patients treated with warfarin. We investigated the impact of percutaneous left atrial appendage closure on post-stroke neurological outcomes in NVAF patients, compared with non-vitamin K antagonist oral anticoagulant (NOAC) therapy. METHODS: Medical records for 1,427 patients in multiple registries and for 1,792 consecutive patients at 6 Korean hospitals were reviewed with respect to LAAO or NOAC treatment. Stroke severity in patients who experienced ischemic stroke or transient ischemic attack after either treatment was assessed with modified Rankin Scale (mRS) scoring at hospital discharge and at 3 and 12 months post-stroke. RESULTS: mRS scores were significantly lower in LAAO patients at 3 (p<0.01) and 12 months (p<0.01) post-stroke, despite no significant differences in scores before the ischemic cerebrovascular event (p=0.22). The occurrences of disabling ischemic stroke in the LAAO and NOAC groups were 36.7% and 44.2% at discharge (p=0.47), 23.3% and 44.2% at 3 months post-stroke (p=0.04), and 13.3% and 43.0% at 12 months post-stroke (p=0.01), respectively. Recovery rates for disabling ischemic stroke at discharge to 12 months post-stroke were significantly higher for LAAO patients (50.0%) than for NOAC patients (5.6%) (p<0.01). CONCLUSIONS: Percutaneous LAAO was associated with more favorable neurological outcomes after ischemic cerebrovascular event than NOAC treatment.

12.
JACC Case Rep ; 2(12): 1979-1983, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34317093

RESUMEN

A patient had a stroke caused by a large, pedunculated aortic ascending mass and was deemed at high risk for near-term recurrent stroke. This case illustrates percutaneous aspiration thrombectomy of ascending aortic thrombus with the AngioVac system (Angiodynamics, Latham, New York), with conscious sedation for early stroke detection and with endovascular cerebral embolic protection. (Level of Difficulty: Intermediate.).

14.
J Invasive Cardiol ; 31(4): E64-E65, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30927537
15.
J Invasive Cardiol ; 31(2): E41-E42, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30700631

RESUMEN

Although reported failure rates of the Watchman device are low, the ballshaped device is not suitable for shallow and multilobed left atrial appendages (LAAs). The LAmbre device is available in two configurations - standard (cover 4-6 mm larger in diameter than the umbrella) and special (cover 12- 14 mm larger than the umbrella) - which allows the closure of a wide range of LAA anatomies. This case illustrates that the LAmbre device can be used for complex LAA anatomies that are not suitable for the Watchman device.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Ecocardiografía Tridimensional/métodos , Ecocardiografía Transesofágica/métodos , Dispositivo Oclusor Septal , Anciano , Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico , Cateterismo Cardíaco , Femenino , Humanos
16.
J Invasive Cardiol ; 30(9): E93-E94, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30158327

RESUMEN

A 72-year-old woman with severe mitral and tricuspid regurgitation secondary to chronic atrial fibrillation presented with refractory heart failure despite optimal medical treatment. She was considered inoperable, and thus underwent transcatheter edge-to-edge repair of both valves using the MitraClip system as a compassionate use.


Asunto(s)
Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Instrumentos Quirúrgicos , Técnicas de Sutura/instrumentación , Insuficiencia de la Válvula Tricúspide/cirugía , Válvula Tricúspide/cirugía , Anciano , Ecocardiografía Transesofágica , Femenino , Humanos , Prótesis e Implantes , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/fisiopatología
20.
J Am Soc Echocardiogr ; 29(10): 938-945, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27545445

RESUMEN

BACKGROUND: Accurate localization of mitral valve prolapse (MVP) is crucial for surgical planning. Despite improved visualization of the mitral valve by three-dimensional transesophageal echocardiography, image interpretation remains expertise dependent. Manual construction of mitral valve topographic maps improves diagnostic accuracy but is time-consuming and requires substantial manual input. A novel computer-learning technique called Anatomical Intelligence in ultrasound (AIUS) semiautomatically tracks the annulus and leaflet anatomy for parametric analysis. The aims of this study were to examine whether AIUS could improve accuracy and efficiency in localizing MVP among operators with different levels of experience. METHODS: Two experts and four intermediate-level echocardiographers (nonexperts) retrospectively performed analysis of three-dimensional transesophageal echocardiographic images to generate topographic mitral valve models in 90 patients with degenerative MVP. All echocardiographers performed both AIUS and manual segmentation in sequential weekly sessions. The results were compared with surgical findings. RESULTS: Manual segmentation by nonexperts had significantly lower sensitivity (60% vs 90%, P < .001), specificity (91% vs 97%, P = .001), and accuracy (83% vs 95%, P < .001) compared with experts. AIUS significantly improved the accuracy of nonexperts (from 83% to 89%, P = .003), particularly for lesions involving the A3 (from 81% to 94%, P = .006) and P1 (from 78% to 88%, P = .001) segments, presumably related to anatomic variants of the annulus that made tracking more challenging. AIUS required significantly less time for image analysis by both experts (1.9 ± 0.7 vs 9.9 ± 3.5 min, P < .0001) and nonexperts (5.0 ± 0.5 vs 13 ± 1.5 min, P < .0001), especially for complex lesions. CONCLUSIONS: Anatomic assessment of mitral valve pathology by three-dimensional transesophageal echocardiography is experience dependent. A semiautomated algorithm using AIUS improves accuracy and efficiency in localizing MVP by less experienced operators.


Asunto(s)
Ecocardiografía Tridimensional/métodos , Interpretación de Imagen Asistida por Computador/métodos , Aprendizaje Automático , Prolapso de la Válvula Mitral/diagnóstico por imagen , Prolapso de la Válvula Mitral/patología , Reconocimiento de Normas Patrones Automatizadas/métodos , Algoritmos , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA