Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anal Methods ; 16(26): 4234-4239, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38899488

RESUMEN

Melanoma inhibitory activity protein (MIA) does obviously offer the potential to reveal clinical manifestations of melanoma. Despite a pressing need for effective diagnosis of this highly fatal disease, there are no clinically approved MIA detection ELISA kits available. A recommended MIA threshold has not yet been defined, mostly by reason of variability in immunoglobulins' affinity and stability, the difference in sample preparation and assay conditions. Here we present a pair of high-affinity DNA aptamers developed as an alternative recognition and binding element for MIA detection. Their stability and reproducible synthesis are expected to ensure this analysis under standard conditions. The devised aptamer-based solid-phase microassay of model standard and control human sera involves luciferase NLuc as a highly sensitive reporter. Bioluminescence dependence on MIA concentration ranges in a linear manner from 2.5 to 250 ng mL-1, providing a MIA detection limit of 1.67 ± 0.57 ng mL-1.


Asunto(s)
Aptámeros de Nucleótidos , Mediciones Luminiscentes , Melanoma , Humanos , Aptámeros de Nucleótidos/química , Mediciones Luminiscentes/métodos , Melanoma/sangre , Proteínas de Neoplasias/sangre , Proteínas de Neoplasias/análisis , Límite de Detección , Biomarcadores de Tumor/sangre , Proteínas de la Matriz Extracelular
2.
Photochem Photobiol ; 96(5): 1041-1046, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32304233

RESUMEN

Bioluminescent solid-phase analysis was proposed to monitor the selection process and to determine binding characteristics of the aptamer-target complexes during design and development of the specific aptamers. The assay involves Ca2+ -regulated photoprotein obelin as a simple, sensitive and fast reporter. Applicability and the prospects of the approach were exemplified by identification of DNA aptamers to cardiac troponin I, a highly specific early biomarker for acute myocardial infarction. Two structurally different aptamers specific to various epitopes of troponin I were obtained and then tested in a model bioluminescent assay.


Asunto(s)
Calcio/química , Proteínas Luminiscentes/química , Técnica SELEX de Producción de Aptámeros/métodos , Troponina I/análisis , Aptámeros de Nucleótidos/química , Secuencia de Bases , Biomarcadores/análisis , Límite de Detección , Mediciones Luminiscentes
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA