Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
J Cardiovasc Magn Reson ; 22(1): 89, 2020 12 17.
Artículo en Inglés | MEDLINE | ID: mdl-33327958

RESUMEN

BACKGROUND: Late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) represents the gold standard for assessment of myocardial viability. The purpose of this study was to investigate the clinical potential of Compressed SENSE (factor 5) accelerated free-breathing three-dimensional (3D) whole heart LGE with high isotropic spatial resolution (1.4 mm3 acquired voxel size) compared to standard breath-hold LGE imaging. METHODS: This was a retrospective, single-center study of 70 consecutive patients (45.8 ± 18.1 years, 27 females; February-November 2019), who were referred for assessment of left ventricular myocardial viability and received free-breathing and breath-hold LGE sequences at 1.5 T in clinical routine. Two radiologists independently evaluated global and segmental LGE in terms of localization and transmural extent. Readers scored scans regarding image quality (IQ), artifacts, and diagnostic confidence (DC) using 5-point scales (1 non-diagnostic-5 excellent/none). Effects of heart rate and body mass index (BMI) on IQ, artifacts, and DC were evaluated with ordinal logistic regression analysis. RESULTS: Global LGE (n = 33) was identical for both techniques. Using free-breathing LGE (average scan time: 04:33 ± 01:17 min), readers detected more hyperenhanced lesions (28.2% vs. 23.5%, P < .05) compared to breath-hold LGE (05:15 ± 01:23 min, P = .0104), pronounced at subepicardial localization and for 1-50% of transmural extent. For free-breathing LGE, readers graded scans with good/excellent IQ in 80.0%, with low-impact/no artifacts in 78.6%, and with good/high DC in 82.1% of cases. Elevated BMI was associated with increased artifacts (P = .0012) and decreased IQ (P = .0237). Increased heart rate negatively influenced artifacts (P = .0013) and DC (P = .0479) whereas IQ (P = .3025) was unimpaired. CONCLUSIONS: In a clinical setting, free-breathing Compressed SENSE accelerated 3D high isotropic spatial resolution whole heart LGE provides good to excellent image quality in 80% of scans independent of heart rate while enabling improved depiction of small and particularly non-ischemic hyperenhanced lesions in a shorter scan time than standard breath-hold LGE.


Asunto(s)
Cardiomiopatías/diagnóstico por imagen , Medios de Contraste , Ventrículos Cardíacos/diagnóstico por imagen , Imagenología Tridimensional , Imagen por Resonancia Cinemagnética , Miocardio/patología , Compuestos Organometálicos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Cardiomiopatías/patología , Bases de Datos Factuales , Femenino , Ventrículos Cardíacos/patología , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Supervivencia Tisular , Adulto Joven
2.
Front Cardiovasc Med ; 10: 1305649, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38099228

RESUMEN

Aim: The purpose of this study was to investigate the clinical application of Compressed SENSE accelerated single-breath-hold LGE with 3D isotropic resolution compared to conventional LGE imaging acquired in multiple breath-holds. Material & Methods: This was a retrospective, single-center study including 105 examinations of 101 patients (48.2 ± 16.8 years, 47 females). All patients underwent conventional breath-hold and 3D single-breath-hold (0.96 × 0.96 × 1.1 mm3 reconstructed voxel size, Compressed SENSE factor 6.5) LGE sequences at 1.5 T in clinical routine for the evaluation of ischemic or non-ischemic cardiomyopathies. Two radiologists independently evaluated the left ventricle (LV) for the presence of hyperenhancing lesions in each sequence, including localization and transmural extent, while assessing their scar edge sharpness (SES). Confidence of LGE assessment, image quality (IQ), and artifacts were also rated. The impact of LV ejection fraction (LVEF), heart rate, body mass index (BMI), and gender as possible confounders on IQ, artifacts, and confidence of LGE assessment was evaluated employing ordinal logistic regression analysis. Results: Using 3D single-breath-hold LGE readers detected more hyperenhancing lesions compared to conventional breath-hold LGE (n = 246 vs. n = 216 of 1,785 analyzed segments, 13.8% vs. 12.1%; p < 0.0001), pronounced at subendocardial, midmyocardial, and subepicardial localizations and for 1%-50% of transmural extent. SES was rated superior in 3D single-breath-hold LGE (4.1 ± 0.8 vs. 3.3 ± 0.8; p < 0.001). 3D single-breath-hold LGE yielded more artifacts (3.8 ± 1.0 vs. 4.0 ± 3.8; p = 0.002) whereas IQ (4.1 ± 1.0 vs. 4.2 ± 0.9; p = 0.122) and confidence of LGE assessment (4.3 ± 0.9 vs. 4.3 ± 0.8; p = 0.374) were comparable between both techniques. Female gender negatively influenced artifacts in 3D single-breath-hold LGE (p = 0.0028) while increased heart rate led to decreased IQ in conventional breath-hold LGE (p = 0.0029). Conclusions: In clinical routine, Compressed SENSE accelerated 3D single-breath-hold LGE yields image quality and confidence of LGE assessment comparable to conventional breath-hold LGE while providing improved delineation of smaller LGE lesions with superior scar edge sharpness. Given the fast acquisition of 3D single-breath-hold LGE, the technique holds potential to drastically reduce the examination time of CMR.

3.
Eur J Radiol ; 116: 135-143, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31153554

RESUMEN

OBJECTIVES: To compare objective and subjective image quality between low keV virtual monoenergetic images (VMI) of the excretory phase and conventional venous phase images derived from spectral dual-energy CT (DECT) in the assessment of urothelial carcinoma. METHODS: 26 consecutive patients with histologically confirmed urothelial carcinoma who received clinically indicated venous- and excretory phase abdominal CT scans were included retrospectively. Attenuation, image noise as well as signal- and contrast-to-noise-ratio (SNR, CNR) in venous and excretory phase CT and excretory phase VMI from 40 to 70 keV were obtained from ROI-based measurements in the following regions: urothelial carcinoma, liver, pancreas, renal cortex, subcutaneous fat, renal vein/artery, portal vein, urinary bladder wall, lymph nodes, prostate/uterus. Subjective vessel contrast and delineation of primary tumor manifestations and distant metastases were rated on 5-point Likert scales. RESULTS: In comparison to venous phase CT, attenuation and SNR in excretory phase VMI40keV were higher (p < 0.001), except for liver parenchyma, where they were comparable (p = 0.07 and p = 0.17, respectively). Regarding image noise, no significant difference was found between venous phase CT and excretory phase VMI40keV (p-range: 0.08-1.00), except for liver, portal vein and renal artery, where it was lower in VMI40keV (p < 0.05). CNR of urothelial carcinoma to circumjacent bladder wall was significantly higher in excretory phase VMI40keV compared to venous phase CT. Subjective vessel contrast and delineation of primary tumor and distant metastases received equivalent or higher Likert scores in excretory phase VMI40keV than in venous phase CT. CONCLUSION: This feasibility study indicates that in the assessment of urothelial carcinoma, virtual monoenergetic excretory phase images at 40 keV acquired with spectral DECT could be feasible to maintain subjective and objective image quality as provided by conventional venous phase images. Still, equivalence with regards to metastatic lesion detection requires further investigation before employing this technique in a potential signal-scan, single-bolus approach.


Asunto(s)
Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Neoplasias Urológicas/diagnóstico por imagen , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Estudios Retrospectivos , Relación Señal-Ruido , Urotelio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA