Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Magn Reson Med ; 92(3): 1115-1127, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38730562

RESUMEN

PURPOSE: T1 mapping is a widely used quantitative MRI technique, but its tissue-specific values remain inconsistent across protocols, sites, and vendors. The ISMRM Reproducible Research and Quantitative MR study groups jointly launched a challenge to assess the reproducibility of a well-established inversion-recovery T1 mapping technique, using acquisition details from a seminal T1 mapping paper on a standardized phantom and in human brains. METHODS: The challenge used the acquisition protocol from Barral et al. (2010). Researchers collected T1 mapping data on the ISMRM/NIST phantom and/or in human brains. Data submission, pipeline development, and analysis were conducted using open-source platforms. Intersubmission and intrasubmission comparisons were performed. RESULTS: Eighteen submissions (39 phantom and 56 human datasets) on scanners by three MRI vendors were collected at 3 T (except one, at 0.35 T). The mean coefficient of variation was 6.1% for intersubmission phantom measurements, and 2.9% for intrasubmission measurements. For humans, the intersubmission/intrasubmission coefficient of variation was 5.9/3.2% in the genu and 16/6.9% in the cortex. An interactive dashboard for data visualization was also developed: https://rrsg2020.dashboards.neurolibre.org. CONCLUSION: The T1 intersubmission variability was twice as high as the intrasubmission variability in both phantoms and human brains, indicating that the acquisition details in the original paper were insufficient to reproduce a quantitative MRI protocol. This study reports the inherent uncertainty in T1 measures across independent research groups, bringing us one step closer to a practical clinical baseline of T1 variations in vivo.


Asunto(s)
Encéfalo , Colaboración de las Masas , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Fantasmas de Imagen , Humanos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Reproducibilidad de los Resultados , Procesamiento de Imagen Asistido por Computador/métodos , Mapeo Encefálico/métodos , Masculino , Femenino , Adulto , Algoritmos
2.
Circulation ; 145(25): 1811-1824, 2022 06 21.
Artículo en Inglés | MEDLINE | ID: mdl-35621277

RESUMEN

BACKGROUND: Endomyocardial biopsy (EMB) is the gold standard method for surveillance of acute cardiac allograft rejection (ACAR) despite its invasive nature. Cardiovascular magnetic resonance (CMR)-based myocardial tissue characterization allows detection of myocarditis. The feasibility of CMR-based surveillance for ACAR-induced myocarditis in the first year after heart transplantation is currently undescribed. METHODS: CMR-based multiparametric mapping was initially assessed in a prospective cross-sectional fashion to establish agreement between CMR- and EMB-based ACAR and to determine CMR cutoff values between rejection grades. A prospective randomized noninferiority pilot study was then undertaken in adult orthotopic heart transplant recipients who were randomized at 4 weeks after orthotopic heart transplantation to either CMR- or EMB-based rejection surveillance. Clinical end points were assessed at 52 weeks. RESULTS: Four hundred one CMR studies and 354 EMB procedures were performed in 106 participants. Forty heart transplant recipients were randomized. CMR-based multiparametric assessment was highly reproducible and reliable at detecting ACAR (area under the curve, 0.92; sensitivity, 93%; specificity, 92%; negative predictive value, 99%) with greater specificity and negative predictive value than either T1 or T2 parametric CMR mapping alone. High-grade rejection occurred in similar numbers of patients in each randomized group (CMR, n=7; EMB, n=8; P=0.74). Despite similarities in immunosuppression requirements, kidney function, and mortality between groups, the rates of hospitalization (9 of 20 [45%] versus 18 of 20 [90%]; odds ratio, 0.091; P=0.006) and infection (7 of 20 [35%] versus 14 of 20 [70%]; odds ratio, 0.192; P=0,019) were lower in the CMR group. On 15 occasions (6%), patients who were randomized to the CMR arm underwent EMB for clarification or logistic reasons, representing a 94% reduction in the requirement for EMB-based surveillance. CONCLUSIONS: A noninvasive CMR-based surveillance strategy for ACAR in the first year after orthotopic heart transplantation is feasible compared with EMB-based surveillance. REGISTRATION: HREC/13/SVH/66 and HREC/17/SVH/80. AUSTRALIAN NEW ZEALAND CLINICAL TRIALS REGISTRY: ACTRN12618000672257.


Asunto(s)
Trasplante de Corazón , Miocarditis , Adulto , Australia/epidemiología , Biopsia/métodos , Estudios Transversales , Rechazo de Injerto/diagnóstico , Trasplante de Corazón/efectos adversos , Humanos , Espectroscopía de Resonancia Magnética , Miocarditis/diagnóstico , Miocardio/patología , Proyectos Piloto , Estudios Prospectivos
3.
Magn Reson Med ; 89(5): 2005-2013, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36585913

RESUMEN

PURPOSE: To evaluate a silent MR active catheter tracking sequence that allows conducting catheter interventions with low acoustic noise levels. METHODS: To reduce the acoustic noise associated with MR catheter tracking, we implemented a technique previously used in conventional MRI. The gradient waveforms are modified to reduce the sound pressure level (SPL) and avoid acoustic resonances of the MRI system. The efficacy of the noise reduction was assessed by software-predicted SPL and verified by measurements. Furthermore, the quality of the catheter tracking signal was assessed in a phantom experiment and during interventional cardiovascular MRI sessions targeted at isthmus-related flutter ablation. RESULTS: The maximum measured SPL in the scanner room was 104 dB(A) for real-time imaging, and 88 dB(A) and 69 dB(A) for conventional and silent tracking, respectively. The SPL measured at different positions in the MR suite using silent tracking were 65-69 dB(A), and thus within the range of a normal conversation. Equivalent signal quality and tracking accuracy were obtained using the silent variant of the catheter tracking sequence. CONCLUSION: Our results indicate that silent MR catheter tracking capabilities are identical to conventional catheter tracking. The achieved acoustic noise reduction comes at no penalty in terms of tracking quality or temporal resolution, improves comfort and safety, and can overcome the need for MR-compatible communication equipment and background noise suppression during the actual interventional procedure.


Asunto(s)
Imagen por Resonancia Magnética Intervencional , Imagen por Resonancia Magnética , Imagen por Resonancia Magnética/métodos , Catéteres , Programas Informáticos , Imagen por Resonancia Magnética Intervencional/métodos , Fantasmas de Imagen
4.
Eur Radiol ; 33(7): 4648-4656, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36683089

RESUMEN

OBJECTIVES: This study analyzed the prevalence and pattern of focal and potential diffuse myocardial fibrosis detected by late gadolinium enhancement (LGE) and extracellular volume (ECV) imaging in male and female marathon runners using cardiac magnetic resonance (CMR). METHODS: Seventy-four marathon runners were studied including 55 males (44 ± 8 years) and 19 females (36 ± 7 years) and compared to 36 controls with similar age and sex using contrast-enhanced CMR, exercise testing, and blood samples. RESULTS: Contrast-enhanced CMR revealed focal myocardial fibrosis in 8 of 74 runners (11%). The majority of runners were male (7 of 8, 88%). LGE was typically non-ischemic in 7 of 8 runners (88%) and ischemic in one runner. ECV was higher in remote myocardium without LGE in male runners (25.5 ± 2.3%) compared to male controls (24.0 ± 3.0%, p < 0.05), indicating the potential presence of diffuse myocardial fibrosis. LV mass was higher in LGE + males (86 ± 18 g/m2) compared to LGE- males (73 ± 14 g/m2, p < 0.05). Furthermore, LGE + males had lower weight (69 ± 9 vs 77 ± 9 kg, p < 0.05) and shorter best marathon finishing times (3.2 ± 0.3 h) compared to LGE- males (3.6 ± 0.4 h, p < 0.05) suggesting higher training load in these runners to accomplish the marathon in a short time. CONCLUSION: The high frequency of non-ischemic myocardial fibrosis in LGE + male runners can be related to increased LV mass in these runners. Furthermore, a higher training load could explain the higher LV mass and could be one additional cofactor in the genesis of myocardial fibrosis in marathon runners. KEY POINTS: • A high frequency of myocardial fibrosis was found in marathon runners. • Myocardial fibrosis occurred typically in male runners and was typically non-ischemic. • Higher training load could be one cofactor in the genesis of myocardial fibrosis in marathon runners.


Asunto(s)
Cardiomiopatías , Medios de Contraste , Masculino , Humanos , Femenino , Carrera de Maratón , Prevalencia , Imagen por Resonancia Cinemagnética , Gadolinio , Miocardio/patología , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/epidemiología , Cardiomiopatías/patología , Fibrosis , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas
5.
J Transl Med ; 20(1): 580, 2022 12 09.
Artículo en Inglés | MEDLINE | ID: mdl-36494667

RESUMEN

BACKGROUND: Muscle fatigue and pain are key symptoms of Myalgic Encephalomyelitis/Chronic Fatigue Syndrome (ME/CFS). Although the pathophysiology is not yet fully understood, there is ample evidence for hypoperfusion which may result in electrolyte imbalance and sodium overload in muscles. Therefore, the aim of this study was to assess levels of sodium content in muscles of patients with ME/CFS and to compare these to healthy controls. METHODS: Six female patients with ME/CFS and six age, BMI and sex matched controls underwent 23Na-MRI of the left lower leg using a clinical 3T MR scanner before and after 3 min of plantar flexion exercise. Sodium reference phantoms with solutions of 10, 20, 30 and 40 mmol/L NaCl were used for quantification. Muscle sodium content over 40 min was measured using a dedicated plugin in the open-source DICOM viewer Horos. Handgrip strength was measured and correlated with sodium content. RESULTS: Baseline tissue sodium content was higher in all 5 lower leg muscle compartments in ME/CFS compared to controls. Within the anterior extensor muscle compartment, the highest difference in baseline muscle sodium content between ME/CFS and controls was found (mean ± SD; 12.20 ± 1.66 mM in ME/CFS versus 9.38 ± 0.71 mM in controls, p = 0.0034). Directly after exercise, tissue sodium content increased in gastrocnemius and triceps surae muscles with + 30% in ME/CFS (p = 0.0005) and + 24% in controls (p = 0.0007) in the medial gastrocnemius muscle but not in the extensor muscles which were not exercised. Compared to baseline, the increase of sodium content in medial gastrocnemius muscle was stronger in ME/CFS than in controls with + 30% versus + 17% to baseline at 12 min (p = 0.0326) and + 29% versus + 16% to baseline at 15 min (p = 0.0265). Patients had reduced average handgrip strength which was associated with increased average muscle tissue sodium content (p = 0.0319, R2 = 0.3832). CONCLUSION: Muscle sodium content before and after exercise was higher in ME/CFS than in healthy controls. Furthermore, our findings indicate an inverse correlation between muscle sodium content and handgrip strength. These findings provide evidence that sodium overload may play a role in the pathophysiology of ME/CFS and may allow for potential therapeutic targeting.


Asunto(s)
Síndrome de Fatiga Crónica , Humanos , Femenino , Fuerza de la Mano , Sodio , Músculo Esquelético , Imagen por Resonancia Magnética
6.
Eur Radiol ; 32(3): 1853-1865, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34536111

RESUMEN

OBJECTIVES: Cancer therapy-related cardiac dysfunction (CTRCD) is a relevant clinical problem and needs early prediction. This study aimed to analyze myocardial injury using serial laboratory and cardiac magnetic resonance imaging (CMR) parameters after epirubicin-based chemotherapy compared with left-sided radiotherapy and to study their value for early prediction of CTRCD. METHODS: Sixty-six consecutive women (53 ± 13 years) including n = 39 with epirubicin-based chemotherapy and n = 27 with left-sided radiotherapy were prospectively studied by 3 T CMR including left ventricular (LV) mass and volumes for ejection fraction (LVEF), as well as feature-tracking with global longitudinal strain (GLS) and T1/T2 mapping. CMR was performed at baseline, at therapy completion (follow-up 1, FU1), and after 13 ± 2 months (FU2). CTRCD was defined as LVEF decline of at least 10% to < 55% or a > 15% GLS change at FU2. RESULTS: T1 and T2 increased at FU1 after epirubicin-based chemotherapy, but not after left-sided radiotherapy. CTRCD occurred in 20% of patients after epirubicin-based chemotherapy and in 4% after left-sided radiotherapy. T1 at FU1 was the best single parameter to predict CTRCD with an area under the curve (AUC) of 0.712 (CI 0.587-0.816, p = 0.005) with excellent sensitivity (100%, 66-100%), but low specificity (44%, 31-58%). Combined use of increased T1 and LVEF ≤ 60% at FU1 improved AUC to 0.810 (0.695-0.896) resulting in good sensitivity (78%, 44-95%) and specificity (84%, 72-92%). CONCLUSION: Only epirubicin-based chemotherapy, but not left-sided radiotherapy, resulted in increased T1/T2 myocardial relaxation times as a marker of myocardial injury. Combined use of CMR parameters may allow an early prediction of subsequent CTCRD. KEY POINTS: • Myocardial T1 and T2 relaxation times increased at FU1 after epirubicin-based chemotherapy, but not after left-sided radiotherapy. • Cancer therapy-related cardiac dysfunction (CTRCD) occurred in 20% of patients after epirubicin-based chemotherapy and in 4% after left-sided radiotherapy. • Combined use of increased T1 and reduced LVEF had an AUC of 0.810 (0.695-0.896) to predict CTRCD with good sensitivity (78%, 44-95%) and specificity (84%, 72-92%).


Asunto(s)
Neoplasias de la Mama , Cardiopatías , Disfunción Ventricular Izquierda , Neoplasias de la Mama/tratamiento farmacológico , Neoplasias de la Mama/radioterapia , Cardiotoxicidad/diagnóstico por imagen , Cardiotoxicidad/etiología , Epirrubicina/efectos adversos , Femenino , Humanos , Imagen por Resonancia Magnética , Imagen por Resonancia Cinemagnética , Valor Predictivo de las Pruebas , Volumen Sistólico , Disfunción Ventricular Izquierda/inducido químicamente , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda
7.
Eur Radiol ; 30(4): 2072-2081, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31828412

RESUMEN

OBJECTIVES: The aim of the study was to establish the setup and workflow for delivering focal MRI-guided high-dose-rate (HDR) brachytherapy for prostate cancer (PCA) and to assess patient comfort and safety aspects of MRI-guided single-fraction HDR. METHODS: Patients with histologically proven focal low- to intermediate-risk PCA with a single PIRADS 4/5 lesion were treated with percutaneous interstitial HDR brachytherapy in a single fraction with a minimum dose for the gross tumor volume of 20 Gy while sparing the organ at risk (OAR). Using a 3T-MRI, brachytherapy catheters were placed transgluteal in freehand technique. No antibiotic therapy or general analgesics were administered. Patient data, procedure time, patient discomfort, and complications were recorded. Quarterly PSA controls, biannual follow-up imaging, and annual re-biopsy were planned. RESULTS: So far, 9 patients were successfully treated and followed for 6 months. Mean intervention time was 34 min. Using the VAS scale, the pain reported for the intervention ranged from 2 to 3. Short-term follow-up showed no acute genitourinary or gastrointestinal toxicity so far. None of the patients displayed signs of infection. PSA levels in all patients decreased significantly. On follow up no residual PCA was detected treated region so far. PSA levels in all patients decreased significantly. On follow-up, no residual PCA was detected so far. CONCLUSIONS: MR-guided single-fraction focal HDR brachytherapy for localized PCA is feasible as well as safe for the individual patient. Catheters can be placed accurately and maximum therapeutic dose distribution can be restricted to the tumor. Countersigning the minimally invasive character of the procedure, no general anesthesia or antibiosis is necessary. KEY POINTS: • MR-guided focal HDR brachytherapy allows an accurate placement of catheters with maximum therapeutic dose distribution restricted to the tumor. • No major anesthesia or antibiosis is necessary emphasizing the minimal invasive character of the procedure. • Patients with low- and intermediate-risk prostate carcinoma in particular may benefit to halt disease progression whereas treatment-related morbidity is reduced compared with radical therapy.


Asunto(s)
Braquiterapia/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/radioterapia , Anciano , Biomarcadores de Tumor/metabolismo , Biopsia , Estudios de Factibilidad , Humanos , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Antígeno Prostático Específico/metabolismo , Neoplasias de la Próstata/metabolismo , Neoplasias de la Próstata/patología , Dosificación Radioterapéutica
8.
Circ J ; 83(7): 1553-1562, 2019 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-31080228

RESUMEN

BACKGROUND: To analyze the effect of myocardial fibrosis on left ventricular (LV) function evaluated by feature-tracking strain analysis by cine cardiac magnetic resonance (CMR) in competitive male triathletes with normal ejection fraction (EF).Methods and Results:78 asymptomatic male triathletes with >10 weekly training hours (43±11 years) and 28 male age-matched controls were studied by late gadolinium enhancement (LGE) and cine CMR. Global and segmental radial, longitudinal and circumferential strains were analyzed using feature-tracking cine CMR. Focal non-ischemic LGE was observed in 15 of 78 triathletes (19%, LGE+) with predominance in the basal inferolateral segments. LVEF was normal in LGE+ (62±6%) and LGE- triathletes (62±5%, P=0.958). In contrast, global radial strain was lower in LGE+ triathletes at 40±7% compared with LGE- triathletes (45±7%, P<0.05). Reduced segmental radial strain occurred either in LGE+ segments or in directly adjacent segments. Strain analysis revealed regional differences in controls, with the highest radial and longitudinal strain in the inferolateral segments, which were typically affected by fibrosis in LGE+ triathletes. CONCLUSIONS: Reduced global and regional radial strain suggests a negative effect of myocardial fibrosis on LV function in LGE+ triathletes with normal EF. The observed regional differences in controls with the highest radial and longitudinal strain in the inferolateral segments may explain the typical occurrence of fibrosis in this myocardial region in triathletes.


Asunto(s)
Atletas , Cardiomiopatías , Imagen por Resonancia Cinemagnética , Miocardio , Volumen Sistólico , Función Ventricular Izquierda , Adolescente , Adulto , Anciano , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/fisiopatología , Fibrosis , Humanos , Masculino , Persona de Mediana Edad
9.
BMC Cardiovasc Disord ; 19(1): 52, 2019 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-30836942

RESUMEN

BACKGROUND: Recently introduced fast strain-encoded (SENC) cardiac magnetic resonance (CMR) imaging (fast-SENC) provides real-time acquisition of myocardial performance in a single heartbeat. We aimed to test the ability and accuracy of real-time strain-encoded CMR imaging to estimate left ventricular volumes, ejection fraction and mass. METHODS: Thirty-five subjects (12 healthy volunteers and 23 patients with known or suspected coronary artery disease) were investigated. All study participants were imaged at 1.5 Tesla MRI scanner (Achieva, Philips) using an advanced CMR study protocol which included conventional cine and fast-SENC imaging. A newly developed real-time free-breathing SENC imaging technique based on the acquisition of two images with different frequency modulation was employed. RESULTS: All parameters were successfully derived from fast-SENC images with total study time of 105 s (a 15 s scan time and a 90 s post-processing time). There was no significant difference between fast-SENC and cine imaging in the estimation of LV volumes and EF, whereas fast-SENC underestimated LV end-diastolic mass by 7%. CONCLUSION: The single heartbeat fast-SENC technique can be used as a good alternative to cine imaging for the precise calculation of LV volumes and ejection fraction while the technique significantly underestimates LV end-diastolic mass.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen por Resonancia Cinemagnética , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda , Adulto , Anciano , Estudios de Casos y Controles , Enfermedad de la Arteria Coronaria/fisiopatología , Femenino , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Proyectos Piloto , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Factores de Tiempo , Disfunción Ventricular Izquierda/fisiopatología , Flujo de Trabajo , Adulto Joven
11.
Eur Radiol ; 28(1): 348-355, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28698943

RESUMEN

OBJECTIVES: This study noninvasively examined the electrical conductivity (σ) characteristics of diffuse gliomas using MRI and tested its validity. METHODS: MRI including a 3D steady-state free precession (3D SSFP) sequence was performed on 30 glioma patients. The σ maps were reconstructed from the phase images of the 3D SSFP sequence. The σ histogram metrics were extracted and compared among the contrast-enhanced (CET) and noncontrast-enhanced tumour components (NCET) and normal brain parenchyma (NP). Difference in tumour σ histogram metrics among tumour grades and correlation of σ metrics with tumour grades were tested. Validity of σ measurement using this technique was tested by correlating the mean tumour σ values measured using MRI with those measured ex vivo using a dielectric probe. RESULTS: Several σ histogram metrics of CET and NCET of diffuse gliomas were significantly higher than NP (Bonferroni-corrected p ≤ .045). The maximum σ of NCET showed a moderate positive correlation with tumour grade (r = .571, Bonferroni-corrected p = .018). The mean tumour σ measured using MRI showed a moderate positive correlation with the σ measured ex vivo (r = .518, p = .040). CONCLUSIONS: Tissue σ can be evaluated using MRI, incorporation of which may better characterise diffuse gliomas. KEY POINTS: • This study tested the validity of noninvasive electrical conductivity measurements by MRI. • This study also evaluated the electrical conductivity characteristics of diffuse glioma. • Gliomas have higher electrical conductivity values than the normal brain parenchyma. • Noninvasive electrical conductivity measurement can be helpful for better characterisation of glioma.


Asunto(s)
Neoplasias Encefálicas/patología , Conductividad Eléctrica , Glioma/patología , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Neoplasias Encefálicas/diagnóstico por imagen , Niño , Femenino , Glioma/diagnóstico por imagen , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Adulto Joven
12.
Radiology ; 285(1): 83-91, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28678672

RESUMEN

Purpose To analyze the diagnostic accuracy of native T1 and T2 mapping compared with visual and quantitative assessment of edema on T2-weighted cardiac magnetic resonance (MR) images to differentiate between acute and chronic myocardial infarction. Materials and Methods This study had institutional ethics committee approval. Written informed consent was obtained from 67 consecutive patients (57 years ± 12; 78% men) with a first acute myocardial infarction, who were prospectively enrolled between April 2011 and June 2015. Four serial 1.5-T MR imaging examinations were performed at 8 days ± 5, 7 weeks ± 2, 3 months ± 0.5, and 6 months ± 1.4 after infarction and included T2-weighted, native T1/T2 mapping, and late gadolinium enhancement MR imaging. Complete follow-up data were obtained in 42 patients. Regional native T1/T2 relaxation time, T2-weighted ratio, and extracellular volume were serially measured in infarcted and remote myocardium. Receiver operating characteristic (ROC) analysis was used to determine the diagnostic accuracy of the MR imaging parameters for discriminating between acute and chronic myocardial infarction. Results Native T1 of infarcted myocardium decreased from 1286 msec ± 99 at baseline to 1077 msec ± 50 at 6 months (P < .0001), whereas T2 decreased from 84 msec ± 10 to 58 msec ± 4 (P < .0001). The T2-weighted ratio decreased from 4.1 ± 1.0 to 2.4 ± 0.6 (P < .0001). Of all the MR imaging parameters obtained, native T1 and T2 yielded the best areas under the ROC curve (AUCs) of 0.975 and 0.979, respectively, for differentiating between acute and chronic myocardial infarction. Visual analysis of the presence of edema at standard T2-weighted cardiac MR imaging resulted in an inferior AUC of 0.863 (P < .01). Conclusion Native T1 and T2 of infarcted myocardium are excellent discriminators between acute and chronic myocardial infarction and are superior to all other MR imaging parameters. Online supplemental material is available for this article.


Asunto(s)
Imagen por Resonancia Cinemagnética/métodos , Imagen por Resonancia Cinemagnética/estadística & datos numéricos , Infarto del Miocardio/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Corazón/diagnóstico por imagen , Corazón/fisiología , Corazón/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
13.
Eur Radiol ; 27(12): 5169-5178, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28656464

RESUMEN

OBJECTIVES: To re-evaluate a recently suggested approach of quantifying myocardial oedema and increased tissue inhomogeneity in myocarditis by T2-mapping. METHODS: Cardiac magnetic resonance data of 99 patients with myocarditis were retrospectively analysed. Thirthy healthy volunteers served as controls. T2-mapping data were acquired at 1.5 T using a gradient-spin-echo T2-mapping sequence. T2-maps were segmented according to the 16-segments AHA-model. Segmental T2-values, segmental pixel-standard deviation (SD) and the derived parameters maxT2, maxSD and madSD were analysed and compared to the established Lake Louise criteria (LLC). RESULTS: A re-estimation of logistic regression models revealed that all models containing an SD-parameter were superior to any model containing global myocardial T2. Using a combined cut-off of 1.8 ms for madSD + 68 ms for maxT2 resulted in a diagnostic sensitivity of 75% and specificity of 80% and showed a similar diagnostic performance compared to LLC in receiver-operating-curve analyses. Combining madSD, maxT2 and late gadolinium enhancement (LGE) in a model resulted in a superior diagnostic performance compared to LLC (sensitivity 93%, specificity 83%). CONCLUSIONS: The results show that the novel T2-mapping-derived parameters exhibit an additional diagnostic value over LGE with the inherent potential to overcome the current limitations of T2-mapping. KEY POINTS: • A novel quantitative approach to myocardial oedema imaging in myocarditis was re-evaluated. • The T2-mapping-derived parameters maxT2 and madSD were compared to traditional Lake-Louise criteria. • Using maxT2 and madSD with dedicated cut-offs performs similarly to Lake-Louise criteria. • Adding maxT2 and madSD to LGE results in further increased diagnostic performance. • This novel approach has the potential to overcome the limitations of T2-mapping.


Asunto(s)
Edema Cardíaco/diagnóstico por imagen , Corazón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Miocarditis/diagnóstico por imagen , Adulto , Anciano , Estudios de Casos y Controles , Femenino , Gadolinio , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Miocarditis/patología , Estudios Retrospectivos , Sensibilidad y Especificidad
14.
Eur Radiol ; 27(12): 5136-5145, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28616729

RESUMEN

OBJECTIVES: To evaluate the ability of late gadolinium enhancement (LGE) and mapping cardiac magnetic resonance (CMR) including native T1 and global extracellular volume (ECV) to identify hypertrophic cardiomyopathy (HCM) patients at risk for sudden cardiac death (SCD) and to predict syncope or non-sustained ventricular tachycardia (VT). METHODS: A 1.5-T CMR was performed in 73 HCM patients and 16 controls. LGE size was quantified using the 3SD, 5SD and full width at half maximum (FWHM) method. T1 and ECV maps were generated by a 3(3)5 modified Look-Locker inversion recovery sequence. Receiver-operating curve analysis evaluated the best parameter to identify patients with increased SCD risk ≥4% and patients with syncope or non-sustained VT. RESULTS: Global ECV was the best predictor of SCD risk with an area under the curve (AUC) of 0.83. LGE size was significantly inferior to global ECV with an AUC of 0.68, 0.70 and 0.70 (all P < 0.05) for 3SD-, 5SD- and FWHM-LGE, respectively. Combined use of the SCD risk score and global ECV significantly improved the diagnostic accuracy to identify HCM patients with syncope or non-sustained VT. CONCLUSIONS: Combined use of the SCD risk score and global ECV has the potential to improve HCM patient selection, benefiting most implantable cardioverter defibrillators. KEY POINTS: • Global ECV identified the best HCM patients with increased SCD risk. • Global ECV performed equally well compared to a SCD risk score. • Combined use of the SCD risk score and global ECV improved test accuracy. • Combined use potentially improves selection of HCM patients for ICD implantation.


Asunto(s)
Cardiomiopatía Hipertrófica/diagnóstico por imagen , Muerte Súbita Cardíaca , Imagen por Resonancia Magnética/métodos , Medición de Riesgo/métodos , Síncope , Taquicardia Ventricular , Adulto , Anciano , Área Bajo la Curva , Volumen Cardíaco , Estudios de Casos y Controles , Medios de Contraste , Muerte Súbita Cardíaca/patología , Femenino , Gadolinio , Humanos , Masculino , Persona de Mediana Edad , Miocardio/patología , Probabilidad , Síncope/patología
15.
J Cardiovasc Magn Reson ; 19(1): 71, 2017 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-28931401

RESUMEN

BACKGROUND: The aim of this study was to evaluate the diagnostic potential of a novel cardiovascular magnetic resonance (CMR) based multiparametric imaging approach in suspected myocarditis and to compare it to traditional Lake Louise criteria (LLC). METHODS: CMR data from 67 patients with suspected acute myocarditis were retrospectively analyzed. Seventeen age- and gender-matched healthy subjects served as control. T2-mapping data were acquired using a Gradient-Spin-Echo T2-mapping sequence in short-axis orientation. T2-maps were segmented according to the 16-segments AHA-model and segmental T2 values and pixel-standard deviation (SD) were recorded. Afterwards, the parameters maxT2 (the highest segmental T2 value) and madSD (the mean absolute deviation (MAD) of the pixel-SDs) were calculated for each subject. Cine sequences in three long axes and a stack of short-axis views covering the left and right ventricle were analyzed using a dedicated feature tracking algorithm. RESULTS: A multiparametric imaging model containing madSD and LV global circumferential strain (GCSLV) resulted in the highest diagnostic performance in receiver operating curve analyses (area under the curve [AUC] 0.84) when compared to any model containing a single imaging parameter or to LLC (AUC 0.79). Adding late gadolinium enhancement (LGE) to the model resulted in a further increased diagnostic performance (AUC 0.93) and yielded the highest diagnostic sensitivity of 97% and specificity of 77%. CONCLUSIONS: A multiparametric CMR imaging model including the novel T2-mapping derived parameter madSD, the feature tracking derived strain parameter GCSLV and LGE yields superior diagnostic sensitivity in suspected acute myocarditis when compared to any imaging parameter alone and to LLC.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Miocarditis/diagnóstico por imagen , Adulto , Algoritmos , Área Bajo la Curva , Fenómenos Biomecánicos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Contracción Miocárdica , Miocarditis/fisiopatología , Valor Predictivo de las Pruebas , Curva ROC , Reproducibilidad de los Resultados , Estudios Retrospectivos , Función Ventricular Izquierda , Función Ventricular Derecha , Adulto Joven
16.
Circ J ; 81(5): 701-708, 2017 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-28179611

RESUMEN

BACKGROUND: Use of cocaine is widespread and associated with several cardiovascular diseases. Recent CMR studies indicate frequent myocardial scar/fibrosis in asymptomatic cocaine abusers (CA).Methods and Results:This study used a combination of advanced CMR tissue characterization techniques, including late gadolinium enhancement (LGE) for focal, and extracellular volume (ECV) imaging for diffuse myocardial injury/fibrosis, with circulating biomarkers for a comprehensive characterization of myocardial injury. We included 20 cardiac asymptomatic CA and a control group of 20 healthy volunteers. The comprehensive assessment included physical examination, resting ECG, exercise ECG, cardiac biomarkers, transthoracic echocardiogram and CMR. We did not find significant differences between CA and controls either in functional CMR parameters such as LVEDVi, LVESVi, LVEF, LV mass index, or in global myocardial ECV. Neither CA nor controls had evidence of myocardial edema on T2-weighted CMR, but 8 CA (40%), and none of the controls had focal myocardial scar (P<0.01). Interestingly, CA with focal myocardial scar on LGE had significantly higher high-sensitivity troponin I (hs-TNI) compared with CA without focal scar (median, 1.7 ng/L; IQR, 1.3-2.5 ng/L vs. 0.6 ng/L; 0.4-1.3 ng/L; P<0.01). CONCLUSIONS: Focal myocardial injury in terms of subtle LGE in 40% of asymptomatic CA was associated with higher hs-TNI. Comprehensive assessment including advanced ECV imaging indicates a focal rather than diffuse pattern of myocardial involvement in asymptomatic CA.


Asunto(s)
Cardiomiopatías/diagnóstico , Trastornos Relacionados con Cocaína/complicaciones , Adulto , Biomarcadores/sangre , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/patología , Estudios de Casos y Controles , Trastornos Relacionados con Cocaína/patología , Edema/diagnóstico por imagen , Edema/etiología , Femenino , Fibrosis/diagnóstico por imagen , Fibrosis/etiología , Adhesiones Focales , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Troponina I/sangre
17.
Pacing Clin Electrophysiol ; 40(2): 175-182, 2017 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-27995637

RESUMEN

BACKGROUND: Extensive and repeated substrate modification (SM) is frequently performed as an ablation strategy in persistent atrial fibrillation (persAF). The effect of these extended ablation strategies on atrial function has not been investigated sufficiently so far. The purpose was to assess atrial function by cardiac magnetic resonance (CMR) and its association with left atrial (LA) scar burden by electroanatomical voltage-mapping after multiple persAF ablation procedures. METHODS: We included 16 persAF patients who had ≥2 SM procedures and a control group (CG) of 21 persAF patients without prior ablation. CMR was performed in sinus rhythm at least 4 weeks after the last cardioversion. Active left and right (RA) atrial emptying fractions (AEF) as well as peak active left atrial appendage (LAA) emptying velocities were obtained by CMR flow measurements. Furthermore, LA scar burden was quantified on electroanatomical voltage maps by the portion of points with local voltage amplitude <0.2 mV. RESULTS: We found median LA-AEF to be lower (13 [9-22] vs 32 [26-36] %, P < 0.001) and median LA scar burden to be higher (40 [20-68] vs nine [3-18] %, P < 0.05) in the SM group compared with the CG. Furthermore, a significant correlation was found between mean LA voltage and LA-AEF (r2 = 0.62, P < 0.001). No significant differences were detected with respect to median RA-AEF (41 [28-48] vs 47 [35-50] %, P = 0.43) and median peak LAA emptying velocities (30 [16-40] vs 17 [13-28] cm/s, P = 0.07). CONCLUSIONS: Active LA function is preserved but significantly impaired and associated with ablation-related LA scar burden after multiple extensive persAF ablations.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Función Atrial , Remodelación Atrial , Ablación por Catéter/efectos adversos , Cicatriz/etiología , Anciano , Fibrilación Atrial/diagnóstico , Enfermedad Crónica , Cicatriz/patología , Cicatriz/fisiopatología , Femenino , Humanos , Imagen por Resonancia Cinemagnética , Masculino , Persona de Mediana Edad , Reoperación/efectos adversos , Resultado del Tratamiento
18.
J Magn Reson Imaging ; 44(5): 1168-1178, 2016 11.
Artículo en Inglés | MEDLINE | ID: mdl-27043352

RESUMEN

PURPOSE: To elucidate the impact of technical and intraindividual reproducibility on the overall variability of myocardial T2 relaxation times. MATERIALS AND METHODS: Thirty healthy volunteers were examined three times (day 1 morning/evening, evening after 2-3 weeks) at 1.5T. During each examination three different T2 -mapping sequences were acquired twice at three slices in short axis view: multi-echo-spin-echo (MESE), T2 -prepared balanced steady-state free precession (SSFP) (T2 prep), and gradient-spin-echo with and without fat saturation (GraSE/GraSEFS ). Repeated measurements were performed for T2 prep and GraSE. Segmented T2 -maps were generated for each slice according to the American Heart Association (AHA) 16-segment model. RESULTS: The coefficients of variation and intraclass correlation coefficients for intraobserver variability were: 1.3% and 0.89 for T2 prep, 1.5% and 0.93 for GraSE, 3.1% and 0.83 for MESE; and for interobserver variability: 3.3% and 0.66 for T2 prep, 2.0% and 0.83 for GraSE, 3.6% and 0.77 for MESE. No systematic difference of T2 times was observed due to diurnal effects and on long-term analysis using one-way analysis of variance (ANOVA) with Tukey-type multiple comparisons (morning vs. evening scan for T2 prep: 52.5 ± 2.4 vs. 51.7 ± 2.7 msec, P = 0.119; for GraSE: 58.6 ± 4.0 vs. 58.5 ± 3.8 msec, P = 0.984; for GraSEFS 57.1 ± 3.2 vs. 57.2 ± 3.9 msec, P = 0.998, and for MESE: 53.8 ± 2.7 vs. 53.3 ± 3.3 msec, P = 0.541; scans between weeks for T2 prep: 51.7 ± 2.7 vs. 51.4 ± 2.4 msec, P = 0.873; for GraSE: 58.5 ± 3.8 vs. 58.1 ± 3.4 msec, P = 0.736; for GraSEFS : 57.2 ± 3.9 vs. 57.0 ± 4.6 msec, P = 0.964, and for MESE: 53.3 ± 3.3 vs. 53.4 ± 2.4 msec, P = 0.970). ANOVA components, however, demonstrated a greater variance of T2 times over multiple timepoints than for repeated measurements within the same scan (variance components of the model fit for intraday variance vs. repeated measurements: T2 prep 2.22 vs. 1.36, GraSE 3.76 vs. 2.09, GraSEFS 3.96 vs. 1.58, MESE 1.86; and for interweeks variance vs. repeated measurements: T2 prep 2.21 vs. 0.80, GraSE 3.20 vs. 2.10, GraSEFS 8.82 vs. 1.18, and MESE 4.49). CONCLUSION: Technical reproducibility and intra- and interobserver agreement of myocardial T2 relaxation times are excellent and intraindividual variation over time is small. Therefore, we consider subject-related factors to explain most of the interindividual variability of myocardial T2 times reported in previous studies. The acknowledgment of this subject-related, biological variability may be important for the future diagnostic value of T2 -mapping. J. Magn. Reson. Imaging 2016;44:1168-1178.


Asunto(s)
Algoritmos , Técnicas de Imagen Cardíaca/métodos , Ventrículos Cardíacos/anatomía & histología , Ventrículos Cardíacos/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Procesamiento de Señales Asistido por Computador , Adulto , Anciano , Simulación por Computador , Femenino , Humanos , Aumento de la Imagen/métodos , Masculino , Persona de Mediana Edad , Modelos Biológicos , Modelos Estadísticos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
19.
Magn Reson Med ; 73(1): 214-22, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24554395

RESUMEN

PURPOSE: To develop a three-dimensional (3D) free-breathing myocardial T1 mapping sequence for assessment of left ventricle diffuse fibrosis after contrast administration. METHODS: In the proposed sequence, multiple 3D inversion recovery images are acquired in an interleaved manner. A mixed prospective/retrospective navigator scheme is used to obtain the 3D Cartesian k-space data with fully sampled center and randomly undersampled outer k-space. The resulting undersampled 3D k-space data are then reconstructed using compressed sensing. Subsequently, T1 maps are generated by voxel-wise curve fitting of the individual interleaved images. In a phantom study, the accuracy of the 3D sequence was evaluated against two-dimensional (2D) modified Look-Locker inversion recovery (MOLLI) and spin-echo sequences. In vivo T1 times of the proposed method were compared with 2D multislice MOLLI T1 mapping. Subsequently, the feasibility of high-resolution 3D T1 mapping with spatial resolution of 1.7 × 1.7 × 4 mm(3) was demonstrated. RESULTS: The proposed method shows good agreement with 2D MOLLI and the spin-echo reference in phantom. No significant difference was found in the in vivo T1 times estimated using the proposed sequence and the 2D MOLLI technique (myocardium, 330 ± 66 ms versus 319 ± 93 ms; blood pools, 211 ± 68 ms versus 210 ± 98 ms). However, improved homogeneity, as measured using standard deviation of the T1 signal, was observed in the 3D T1 maps. CONCLUSION: The proposed sequence enables high-resolution 3D T1 mapping after contrast injection during free-breathing with volumetric left ventricle coverage.


Asunto(s)
Algoritmos , Ventrículos Cardíacos/patología , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Disfunción Ventricular Izquierda/patología , Adulto , Femenino , Fibrosis , Humanos , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Mecánica Respiratoria , Sensibilidad y Especificidad
20.
J Cardiovasc Magn Reson ; 17: 67, 2015 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-26231927

RESUMEN

BACKGROUND: The aim of this study was the evaluation of a fast Gradient Spin Echo Technique (GraSE) for cardiac T2-mapping, combining a robust estimation of T2 relaxation times with short acquisition times. The sequence was compared against two previously introduced T2-mapping techniques in a phantom and in vivo. METHODS: Phantom experiments were performed at 1.5 T using a commercially available cylindrical gel phantom. Three different T2-mapping techniques were compared: a Multi Echo Spin Echo (MESE; serving as a reference), a T2-prepared balanced Steady State Free Precession (T2prep) and a Gradient Spin Echo sequence. For the subsequent in vivo study, 12 healthy volunteers were examined on a clinical 1.5 T scanner. The three T2-mapping sequences were performed at three short-axis slices. Global myocardial T2 relaxation times were calculated and statistical analysis was performed. For assessment of pixel-by-pixel homogeneity, the number of segments showing an inhomogeneous T2 value distribution, as defined by a pixel SD exceeding 20 % of the corresponding observed T2 time, was counted. RESULTS: Phantom experiments showed a greater difference of measured T2 values between T2prep and MESE than between GraSE and MESE, especially for species with low T1 values. Both, GraSE and T2prep resulted in an overestimation of T2 times compared to MESE. In vivo, significant differences between mean T2 times were observed. In general, T2prep resulted in lowest (52.4 ± 2.8 ms) and GraSE in highest T2 estimates (59.3 ± 4.0 ms). Analysis of pixel-by-pixel homogeneity revealed the least number of segments with inhomogeneous T2 distribution for GraSE-derived T2 maps. CONCLUSIONS: The GraSE sequence is a fast and robust sequence, combining advantages of both MESE and T2prep techniques, which promises to enable improved clinical applicability of T2-mapping in the future. Our study revealed significant differences of derived mean T2 values when applying different sequence designs. Therefore, a systematic comparison of different cardiac T2-mapping sequences and the establishment of dedicated reference values should be the goal of future studies.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Cinemagnética/métodos , Contracción Miocárdica , Función Ventricular Izquierda , Adulto , Femenino , Voluntarios Sanos , Humanos , Imagen por Resonancia Cinemagnética/instrumentación , Masculino , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Volumen Sistólico , Factores de Tiempo , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA