Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 387(14): 1253-1263, 2022 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-36121045

RESUMEN

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) for the treatment of aortic stenosis can lead to embolization of debris. Capture of debris by devices that provide cerebral embolic protection (CEP) may reduce the risk of stroke. METHODS: We randomly assigned patients with aortic stenosis in a 1:1 ratio to undergo transfemoral TAVR with CEP (CEP group) or without CEP (control group). The primary end point was stroke within 72 hours after TAVR or before discharge (whichever came first) in the intention-to-treat population. Disabling stroke, death, transient ischemic attack, delirium, major or minor vascular complications at the CEP access site, and acute kidney injury were also assessed. A neurology professional examined all the patients at baseline and after TAVR. RESULTS: A total of 3000 patients across North America, Europe, and Australia underwent randomization; 1501 were assigned to the CEP group and 1499 to the control group. A CEP device was successfully deployed in 1406 of the 1489 patients (94.4%) in whom an attempt was made. The incidence of stroke within 72 hours after TAVR or before discharge did not differ significantly between the CEP group and the control group (2.3% vs. 2.9%; difference, -0.6 percentage points; 95% confidence interval, -1.7 to 0.5; P = 0.30). Disabling stroke occurred in 0.5% of the patients in the CEP group and in 1.3% of those in the control group. There were no substantial differences between the CEP group and the control group in the percentage of patients who died (0.5% vs. 0.3%); had a stroke, a transient ischemic attack, or delirium (3.1% vs. 3.7%); or had acute kidney injury (0.5% vs. 0.5%). One patient (0.1%) had a vascular complication at the CEP access site. CONCLUSIONS: Among patients with aortic stenosis undergoing transfemoral TAVR, the use of CEP did not have a significant effect on the incidence of periprocedural stroke, but on the basis of the 95% confidence interval around this outcome, the results may not rule out a benefit of CEP during TAVR. (Funded by Boston Scientific; PROTECTED TAVR ClinicalTrials.gov number, NCT04149535.).


Asunto(s)
Estenosis de la Válvula Aórtica , Dispositivos de Protección Embólica , Embolia Intracraneal , Implantación de Prótesis , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Lesión Renal Aguda/etiología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Delirio/etiología , Humanos , Embolia Intracraneal/etiología , Embolia Intracraneal/prevención & control , Ataque Isquémico Transitorio/etiología , Implantación de Prótesis/instrumentación , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 102(3): 464-471, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37493431

RESUMEN

BACKGROUND: Ultrathin strut coronary drug-eluting stents (DES) have demonstrated improved safety and efficacy in large contemporary trials. The evaluation of an ultrathin strut DES in a post-market United States (US) patient population was undertaken. OBJECTIVE: The purpose of this post-approval study is to confirm that the clinical performance of an ultrathin strut bioresorbable polymer sirolimus-eluting stent (BP SES) in clinical practice is similar to that observed with BP SES in the BIOFLOW V pivotal trial. METHODS: BIOFLOW VII is a prospective, multicenter, single-arm US post-market approval study to confirm the clinical performance of BP SES in a real-world setting. The primary endpoint of 1-year target lesion failure (TLF) was compared with a performance goal of 6.9% based on an adapted BIOFLOW V trial BP SES TLF rate and TLF rates from other US market-released DES utilizing the Society for Cardiovascular Angiography and Interventions definition for peri-procedural myocardial infarction (MI). Subjects undergoing percutaneous coronary intervention with BP SES were consented within 24 h post-index procedure with planned follow-up through 5 years. RESULTS: Among 556 enrolled patients, clinical demographics included: 34.7% female, 35.6% with diabetes mellitus, and 56.8% with acute coronary syndromes. The average stent length (mean ± standard deviation) was 20.2 ± 11.8 mm, and the mean number of stents per patient was 1.3 ± 0.6. Procedure success was 99.1% (551/556), and device success was 99.9% (689/690). Among 531 subjects included in the primary endpoint analysis, the 1-year rate of TLF rate was 1.7% (9/531), and the primary endpoint was met compared with the performance goal (p < 0.0001, 95% confidence interval: 0.69%, 3.43%). Rates of target vessel MI and clinically driven target lesion revascularization were 1.3% (7/531) and 0.9% (5/531), with no occurrence of cardiac death. Definite stent thrombosis was observed for two cases (0.4%; 2/556) with one acute (≤24 h) and one late (>30 days and ≤1 year) event. CONCLUSION: In a post-approval study, 1-year clinical outcomes with BP SES were consistent with prior trials supporting the safety and effectiveness of ultrathin BP SES.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Femenino , Masculino , Sirolimus/efectos adversos , Everolimus , Polímeros , Implantes Absorbibles , Estudios Prospectivos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Resultado del Tratamiento , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis
3.
Scand Cardiovasc J ; 53(6): 299-304, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31315473

RESUMEN

Objectives. Using composite endpoints and/or only first events in clinical research result in information loss and alternative statistical methods which incorporate recurrent event data exist. We compared information-loss under traditional analyses to alternative models. Design. We conducted a retrospective analysis of patients who underwent percutaneous coronary intervention (Jan2010-Dec2014) and constructed Cox models for a composite endpoint (readmission/death), a shared frailty model for recurrent events, and a joint frailty (JF) model to simultaneously account for recurrent and terminal events and evaluated the impact of heart failure (HF) on the outcome. Results. Among 4901 patients, 2047(41.8%) experienced a readmission or death within 1 year. Of those with recurrent events, 60% had ≥1 readmission and 6% had >4; a total of 121(2.5%) patients died during follow-up. The presence of HF conferred an adjusted Hazard ratio (HR) of 1.32 (95% CI: 1.18-1.47, p < .001) for the risk of composite endpoint (Cox model), 1.44 (95% CI: 1.36-1.52, p < .001) in the frailty model, and 1.34 (95% CI:1.22-1.46, p < .001) in the JF model. However, HF was not associated with death (HR 0.87, 95% CI: 0.52-1.48, p = .61) in the JF model. Conclusions. Using a composite endpoint and/or only the first event yields substantial loss of information, as many individuals endure >1 event. JF models reduce bias by simultaneously providing event-specific HRs for recurrent and terminal events.


Asunto(s)
Readmisión del Paciente , Intervención Coronaria Percutánea/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/mortalidad , Recurrencia , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
JAMA ; 319(1): 27-37, 2018 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-29297076

RESUMEN

Importance: Transcatheter aortic valve replacement (TAVR) is established for selected patients with severe aortic stenosis. However, limitations such as suboptimal deployment, conduction disturbances, and paravalvular leak occur. Objective: To evaluate if a mechanically expanded valve (MEV) is noninferior to an approved self-expanding valve (SEV) in high-risk patients with aortic stenosis undergoing TAVR. Design, Setting, and Participants: The REPRISE III trial was conducted in 912 patients with high or extreme risk and severe, symptomatic aortic stenosis at 55 centers in North America, Europe, and Australia between September 22, 2014, and December 24, 2015, with final follow-up on March 8, 2017. Interventions: Participants were randomized in a 2:1 ratio to receive either an MEV (n = 607) or an SEV (n = 305). Main Outcomes and Measures: The primary safety end point was the 30-day composite of all-cause mortality, stroke, life-threatening or major bleeding, stage 2/3 acute kidney injury, and major vascular complications tested for noninferiority (margin, 10.5%). The primary effectiveness end point was the 1-year composite of all-cause mortality, disabling stroke, and moderate or greater paravalvular leak tested for noninferiority (margin, 9.5%). If noninferiority criteria were met, the secondary end point of 1-year moderate or greater paravalvular leak was tested for superiority in the full analysis data set. Results: Among 912 randomized patients (mean age, 82.8 [SD, 7.3] years; 463 [51%] women; predicted risk of mortality, 6.8%), 874 (96%) were evaluable at 1 year. The primary safety composite end point at 30 days occurred in 20.3% of MEV patients and 17.2% of SEV patients (difference, 3.1%; Farrington-Manning 97.5% CI, -∞ to 8.3%; P = .003 for noninferiority). At 1 year, the primary effectiveness composite end point occurred in 15.4% with the MEV and 25.5% with the SEV (difference, -10.1%; Farrington-Manning 97.5% CI, -∞ to -4.4%; P<.001 for noninferiority). The 1-year rates of moderate or severe paravalvular leak were 0.9% for the MEV and 6.8% for the SEV (difference, -6.1%; 95% CI, -9.6% to -2.6%; P < .001). The superiority analysis for primary effectiveness was statistically significant (difference, -10.2%; 95% CI, -16.3% to -4.0%; P < .001). The MEV had higher rates of new pacemaker implants (35.5% vs 19.6%; P < .001) and valve thrombosis (1.5% vs 0%) but lower rates of repeat procedures (0.2% vs 2.0%), valve-in-valve deployments (0% vs 3.7%), and valve malpositioning (0% vs 2.7%). Conclusions and Relevance: Among high-risk patients with aortic stenosis, use of the MEV compared with the SEV did not result in inferior outcomes for the primary safety end point or the primary effectiveness end point. These findings suggest that the MEV may be a useful addition for TAVR in high-risk patients. Trial Registration: ClinicalTrials.gov Identifier: NCT02202434.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Bioprótesis , Enfermedades Cardiovasculares/etiología , Enfermedades Cardiovasculares/mortalidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
5.
Rev Cardiovasc Med ; 16(4): 261-4, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26827749

RESUMEN

Myocardial infarction (MI) secondary to acute coronary occlusion related to trauma is rare. A previously healthy man developed acute MI shortly after a motor vehicle accident. This case illustrates the feasibility of primary percutaneous coronary intervention for acute MI due to complete coronary artery occlusion related to trauma, including the use of manual thrombectomy, stents, and dual antiplatelet therapy. This approach requires the intervention of a multidisciplinary team in a Level 1 trauma center that can rapidly evaluate the patient and rule out other life-threatening injuries that could preclude antiplatelet therapy.

6.
Artículo en Inglés | MEDLINE | ID: mdl-38599918

RESUMEN

BACKGROUND: The next generation supra-annular, self-expanding Evolut FX transcatheter aortic valve (TAV) system was designed to improve catheter deliverability, provide stable and symmetric valve deployment, and assess commissural alignment during the procedure. The impact of these modifications has not been clinically evaluated. METHODS: Procedural information was collected by survey in 2 Stages: Stage I comprised 23 centers with extensive experience with Evolut TAV systems, and Stage II comprised an additional 46 centers with a broad range of balloon- and self-expanding system experience. Operators were to compare the experience with the Evolut FX to the predicate Evolut PRO+ system. RESULTS: There were 285 cases during Stage I from June 24 to August 12, 2022, and 254 cases during Stage II from August 15 to September 11, 2022. Overall, the cusp overlap technique was used in 88.6 %, and commissural alignment was achieved in 96.1 % of these cases. Compared to implanter's previous experience with the Evolut PRO+ system, less resistance was noted with the Evolut FX system: in 83.0 % of cases during vascular insertion, in 84.7 % of cases while tracking through the vasculature, in 84.4 % of cases while traversing over the arch, and 76.1 % of cases in advancing across the valve. Better symmetry of valve depth was observed in 423 of 525 cases (80.6 %). CONCLUSION: Evolut FX system design modifications translated into improvements in catheter deliverability, deployment symmetry and stability, and commissural alignment as assessed by experienced self-expanding and balloon expandable operators.

7.
Proc (Bayl Univ Med Cent) ; 36(3): 351-353, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37091776

RESUMEN

Background: As the incidence of aortic stenosis is increasing in correlation with the aging population, symptomatic patients commonly require valve replacement procedures. If left untreated, symptomatic aortic stenosis can lead to death in 2 to 3 years. Often, transcatheter aortic valve replacement (TAVR) procedures are performed with the assistance of oxygenation via nasal cannula. However, oxygenation achieved through a nasal continuous positive airway pressure (nCPAP) device could be a more optimized strategy for patients without any sacrifice in efficacy compared to nasal cannula. Methods: A retrospective chart review was conducted on 28 patients at Baylor University Medical Center who presented to the operating room for a TAVR between January and October 2021. Fourteen patients received oxygenation via nasal cannula (control group) and 14 received oxygenation with nCPAP. Information gathered included method of oxygenation, length of stay, episodes of hypoxia (defined as sustained oxygen saturation <92% for at least 1 minute), paravalvular leak, pacemaker placement, and mean atrial valve (AV) gradient before and after the procedure. Results: In the nCPAP group, the average length of stay was 2.79 days vs 2.71 days in the nasal cannula group. In the nCPAP group, no patient required a permanent pacemaker, while the nasal cannula group had a 40% rate of permanent pacemaker placement. The average preprocedure AV gradient was 51.14 in the nCPAP group and 42.57 in the nasal cannula group. The average postprocedure AV gradient was 8.5 in the nCPAP group and 5.36 in the nasal cannula group. Both groups had an intensive care unit admission rate of 0%. The rate of paravalvular leak was 35.7% in the nCPAP group and 28.6% in the nasal cannula group. The nCPAP group had an average of 0 episodes of hypoxia and the nasal cannula group had an average of 0.93 episodes of hypoxia. Conclusion: The findings demonstrate the viability of nCPAP as an effective method of oxygenation during intravenous sedation of TAVR patients when compared to oxygenation achieved via nasal cannula during TAVRs.

8.
Am J Cardiol ; 191: 110-118, 2023 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-36669380

RESUMEN

Discordance exists between Doppler-derived and left heart catheterization (LHC)-derived mean gradient (MG) in transcatheter aortic valve implantation (TAVI). We compared echocardiographic parameters of prosthetic valve stenosis and LHC-derived MG in new TAVIs. In a retrospective, single-center study, intraoperative transesophageal echocardiogram (TEE)-derived MG, LHC-derived MG, and acceleration time (AT) were obtained before and after TAVI in 362 patients. Discharge MG, AT, and Doppler velocity index (DVI) using transthoracic echocardiogram (TTE) were also obtained. MG ≥10 mm Hg was defined as abnormal. During native valve assessment with pre-TAVI TEE and pre-TAVI LHC, Pearson correlation coefficient revealed a nearly perfect linear relation between both methods' MGs (r = 0.97, p <0.0001). Intraoperatively, after TAVI, Spearman correlation coefficient revealed a weak-to-moderate relation between post-TAVI TEE and LHC MGs (r = 0.33, p <0.0001). Significant differences were observed in categorizations between post-TAVI TEE MG and post-TAVI AT (McNemar test p = 0.0003) and between post-TAVI TEE MG and post-TAVI LHC MG (signed-rank test p <0.0001), with TEE MG more likely to misclassify a patient as abnormal. At discharge, 30% of patients had abnormal TTE MG, whereas 0% and 0.8% of patients had abnormal DVI and AT, respectively. Discharge TTE MG was not associated with death or hospitalization for heart failure at a median follow-up of 862 days. Post-TAVI Doppler-derived MG by intraoperative TEE was higher than LHC, despite being virtually identical before implantation. At discharge, patients were more likely to be classified as abnormal using MG than DVI and AT. Elevated MG at discharge was not associated with death or hospitalization for heart failure.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/cirugía , Constricción Patológica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Estudios Retrospectivos , Ecocardiografía , Ecocardiografía Transesofágica , Catéteres , Resultado del Tratamiento
9.
J Am Coll Cardiol ; 81(17): 1663-1674, 2023 05 02.
Artículo en Inglés | MEDLINE | ID: mdl-36882136

RESUMEN

BACKGROUND: Randomized data comparing outcomes of transcatheter aortic valve replacement (TAVR) with surgery in low-surgical risk patients at time points beyond 2 years is limited. This presents an unknown for physicians striving to educate patients as part of a shared decision-making process. OBJECTIVES: The authors evaluated 3-year clinical and echocardiographic outcomes from the Evolut Low Risk trial. METHODS: Low-risk patients were randomized to TAVR with a self-expanding, supra-annular valve or surgery. The primary endpoint of all-cause mortality or disabling stroke and several secondary endpoints were assessed at 3 years. RESULTS: There were 1,414 attempted implantations (730 TAVR; 684 surgery). Patients had a mean age of 74 years and 35% were women. At 3 years, the primary endpoint occurred in 7.4% of TAVR patients and 10.4% of surgery patients (HR: 0.70; 95% CI: 0.49-1.00; P = 0.051). The difference between treatment arms for all-cause mortality or disabling stroke remained broadly consistent over time: -1.8% at year 1; -2.0% at year 2; and -2.9% at year 3. The incidence of mild paravalvular regurgitation (20.3% TAVR vs 2.5% surgery) and pacemaker placement (23.2% TAVR vs 9.1% surgery; P < 0.001) were lower in the surgery group. Rates of moderate or greater paravalvular regurgitation for both groups were <1% and not significantly different. Patients who underwent TAVR had significantly improved valve hemodynamics (mean gradient 9.1 mm Hg TAVR vs 12.1 mm Hg surgery; P < 0.001) at 3 years. CONCLUSIONS: Within the Evolut Low Risk study, TAVR at 3 years showed durable benefits compared with surgery with respect to all-cause mortality or disabling stroke. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283).


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano , Masculino , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Factores de Riesgo , Resultado del Tratamiento , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/cirugía
10.
JAMA Netw Open ; 5(10): e2238792, 2022 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-36301543

RESUMEN

Importance: Long-term follow-up after transcatheter aortic valve replacement (TAVR) is of interest given that longitudinal data on mortality and durability of transcatheter heart valves are limited. The REPRISE III (Repositionable Percutaneous Replacement of Stenotic Aortic Valve Through Implantation of Lotus Valve System-Randomized Clinical Evaluation) randomized clinical trial compared the mechanically expanded Lotus valve with the self-expanding CoreValve/EvolutR TAVR platforms. Objective: To describe the final 5-year outcomes of the REPRISE III trial. Design, Setting, and Participants: This prespecified secondary analysis assessed the final 5-year clinical, functional, and echocardiographic outcomes of 912 patients from the REPRISE III trial, which was conducted at 55 centers in North America, Europe, and Australia between September 22, 2014, and December 24, 2015. Patients had high risk for aortic stenosis or severe or symptomatic aortic stenosis. Data were analyzed from September 22, 2014, to May 21, 2021. Intervention: Lotus valve or CoreValve/EvolutR TAVR platforms. Main Outcomes and Measures: Valve Academic Research Consortium-2 end points, hemodynamic measures, functional status, and health status were examined through the 5-year follow-up. Results: A total of 912 patients (mean [SD] age, 82.8 [7.3] years; 463 women [50.8%]) were randomized to either the Lotus valve group (n = 607) or CoreValve/EvolutR group (n = 305), with a baseline Society of Thoracic Surgeons risk score of 6.8%. Clinical follow-up data from the REPRISE III trial were available for 581 patients (95.7%) in the Lotus valve group and 285 patients (93.4%) in the CoreValve/EvolutR group. At 5 years, the cumulative event rate for all-cause mortality was 50.9% in the Lotus valve group vs 52.8% in the CoreValve/EvolutR group (P = .59). Disabling stroke was less frequent with the Lotus valve vs CoreValve/EvolutR (cumulative event rates, 8.3% vs 12.2%; P = .04), whereas the cumulative event rates for overall stroke were similar in both groups (14.1% vs 15.3%; P = .38). Insertion of a new permanent pacemaker (38.9% vs 27.3%; P < .001) and detection of prosthetic aortic valve thrombosis (5.8% vs 1.8%; P = .007) were more common in the Lotus valve group than in the CoreValve/EvolutR group. A smaller proportion of patients who received the Lotus valve experienced valve malpositioning (0% vs 2.6%; P < .001) and required the use of a second valve (1.0% vs 3.8%; P < .001) during the procedure compared with those who received the CoreValve/EvolutR. Compared with the Lotus valve group, the CoreValve/EvolutR group had a significantly lower mean (SD) aortic gradient (7.8 [4.2] mm Hg vs 12.6 [6.7] mm Hg; P < .001) and larger valve areas (1.57 [0.56] cm2 vs 1.42 [0.42] cm2; P = .10). After 5 years, the proportion of patients with moderate or greater paravalvular leak was not significantly higher with the CoreValve/EvolutR than with the Lotus valve (1.9% vs 0%; P = .31); however, the proportion of patients with mild paravalvular leak was higher in the CoreValve/EvolutR group compared with the Lotus valve group (23.1% vs 7.8%; P = .006). Long-term, similar improvements in New York Heart Association class and Kansas City Cardiomyopathy Questionnaire score were observed in both groups. Conclusions and Relevance: The REPRISE III trial found that, at 5 years, the clinical outcomes of the Lotus valve were comparable to those of the CoreValve/EvolutR and that the Lotus valve was safe and effective. Trial Registration: ClinicalTrials.gov Identifier: NCT02202434.


Asunto(s)
Estenosis de la Válvula Aórtica , Accidente Cerebrovascular , Trombosis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Anciano de 80 o más Años , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Válvula Aórtica/cirugía , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Accidente Cerebrovascular/etiología
12.
Am J Cardiol ; 125(9): 1443-1445, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-32005440

RESUMEN

This report describes a 64-year-old woman who presented with unstable angina pectoris, her first atherosclerotic event, and who underwent coronary bypass including endarterectomy of the entire right coronary artery which was diffusely and severely narrowed by atherosclerotic plaque. Preoperatively, she fulfilled none of the present-day criteria for lipid-lowering drug therapy. The report demonstrates the deficiency of present-day lipid-lowering drug guidelines and emphasizes the need to switch emphasis from decreasing risk of an atherosclerotic event to the prevention of arterial plaques, a goal which will require a much lower threshold of low-density lipoprotein cholesterol to initiate drug therapy.


Asunto(s)
Enfermedad de la Arteria Coronaria/prevención & control , Prevención Primaria , Femenino , Humanos , Persona de Mediana Edad
13.
Am J Cardiol ; 131: 115-119, 2020 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-32723554

RESUMEN

Accumulating evidence suggests that influenza and influenza-like illnesses can act as a trigger for acute myocardial infarction. Despite these unprecedented times providers should not overlook acute coronary syndrome (ACS) guidelines, but may choose to modify the recommended approach in situations with confirmed or suspected COVID-19 disease. In this document, we suggest recommendations as to how to triage patients diagnosed with ACSs and provide with algorithms of how to manage the patients and decide the appropriate treatment options in the era of COVID-19 pandemic. We also address the inpatient logistics and discharge to follow-up considerations for the function of already established ACS network during the pandemic.


Asunto(s)
Síndrome Coronario Agudo/terapia , Betacoronavirus , Infecciones por Coronavirus/complicaciones , Manejo de la Enfermedad , Neumonía Viral/complicaciones , Triaje/métodos , Síndrome Coronario Agudo/complicaciones , COVID-19 , Infecciones por Coronavirus/epidemiología , Humanos , Pandemias , Neumonía Viral/epidemiología , SARS-CoV-2
14.
Proc (Bayl Univ Med Cent) ; 33(4): 520-523, 2020 Jul 13.
Artículo en Inglés | MEDLINE | ID: mdl-33100519

RESUMEN

Coronary angiography is used to assess the burden of coronary artery disease prior to surgical valve repair/replacement and often leads to concomitant bypass and valve surgery. We sought to evaluate outcomes of an alternative, hybrid approach involving percutaneous coronary intervention (PCI) and valve surgery, assessing the rate of stent thrombosis as a primary outcome. We reviewed charts of consecutive patients who underwent planned PCI prior to surgical valve repair/replacement by a single surgeon from January 2008 to December 2016. We calculated rates of surgical complication, duration of dual antiplatelet therapy (DAPT) prior to surgery, and rates of stent thrombosis and in-stent restenosis. Twenty-four patients were included in this study. Surgery was performed a median of 52.5 days following PCI. DAPT was withheld an average of 8 days before and resumed an average of 4 days after surgery. Ninety-two percent of surgeries were minimally invasive. There were no bleeding complications, stent thromboses, or restenosis events. All patients survived the 1-year follow-up. For patients with mixed coronary and valvular heart disease, a heart team approach involving preoperative PCI followed by staged minimally invasive valvular surgery appears to be safe and warrants further exploration.

15.
Am J Cardiol ; 131: 1-6, 2020 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-32732010

RESUMEN

There is limited information regarding clinical characteristics and outcomes of patients with SARS-CoV-2 (COVID-19) disease presenting with ST-segment elevation myocardial infarction (STEMI). In this multicenter retrospective study, we reviewed charts of patients admitted with symptomatic COVID-19 infection and STEMI to a total of 4 hospitals spanning Italy, Lithuania, Spain and Iraq from February 1, 2020 to April 15, 2020. A total of 78 patients were included in this study, 49 (63%) of whom were men, with a median age of 65 [58, 71] years, and high comorbidity burden. During hospitalization, 8 (10%) developed acute respiratory distress syndrome, and 14 (18%) required mechanical ventilation. 19 (24%) patients were treated with primary Percutaneous Coronary Intervention (PCI) and 59 (76%) were treated with fibrinolytic therapy. 13 (17%) patients required cardiac resuscitation, and 9 (11%) died. For the 19 patients treated with primary PCI, 8 (42%) required intubation and 8 (42%) required cardiac resuscitation; stent thrombosis occurred in 4 patients (21%). A total of 5 patients (26%) died during hospitalization. 50 (85%) of the 59 patients initially treated with fibrinolytic therapy had successful fibrinolysis. The median time to reperfusion was 27 minutes [20, 34]. Hemorrhagic stroke occurred in 5 patients (9%). Six patients (10%) required invasive mechanical ventilation; 5 (9%) required cardiac resuscitation, and 4 (7%) died. In conclusion, this is the largest case series to-date of COVID-19 positive patients presenting with STEMI and spans 4 countries. We found a high rate of stent thrombosis, indicating a possible need to adapt STEMI management for COVID-19 patients.


Asunto(s)
Betacoronavirus , Infecciones por Coronavirus/complicaciones , Fibrinolíticos/uso terapéutico , Intervención Coronaria Percutánea/métodos , Neumonía Viral/complicaciones , Infarto del Miocardio con Elevación del ST/terapia , Terapia Trombolítica/métodos , Anciano , COVID-19 , Angiografía Coronaria , Infecciones por Coronavirus/epidemiología , Femenino , Estudios de Seguimiento , Humanos , Incidencia , Italia/epidemiología , Masculino , Persona de Mediana Edad , Pandemias , Neumonía Viral/epidemiología , Estudios Retrospectivos , SARS-CoV-2 , Infarto del Miocardio con Elevación del ST/complicaciones , Infarto del Miocardio con Elevación del ST/diagnóstico , España/epidemiología , Tasa de Supervivencia/tendencias , Resultado del Tratamiento
16.
EuroIntervention ; 16(10): 833-841, 2020 Nov 20.
Artículo en Inglés | MEDLINE | ID: mdl-32715995

RESUMEN

AIMS: In patients with aortic stenosis randomised to transcatheter aortic valve implantation (TAVI) or surgical aortic valve replacement (SAVR), sex-specific differences in complication rates are unclear in intermediate-risk patients. The purpose of this analysis was to identify sex-specific differences in outcome for patients at intermediate surgical risk randomised to TAVI or SAVR in the international Surgical Replacement and Transcatheter Aortic Valve Implantation (SURTAVI) trial. METHODS AND RESULTS: A total of 1,660 intermediate-risk patients underwent TAVI with a supra-annular, self-expanding bioprosthesis or SAVR. The population was stratified by sex and treatment modality (female TAVI=366, male TAVI=498, female SAVR=358, male SAVR=438). The primary endpoint was a composite of all-cause mortality or disabling stroke at two years. Compared to males, females had a smaller body surface area, a higher Society of Thoracic Surgeons score (4.7±1.6% vs 4.3±1.6%, p<0.01) and were more frail. Men required more concomitant revascularisation (23% vs 16%). All-cause mortality or disabling stroke at two years was similar between TAVI and SAVR for females (10.2% vs 10.5%, p=0.90) and males (14.5% vs 14.4%, p=0.99); the difference between females and males was 10.2% vs 14.5%, for TAVI (p=0.08) and 10.5% vs 14.4%, SAVR (p=0.13). Functional status improvement was more pronounced after TAVI in females than in males. CONCLUSIONS: Aortic valve replacement, either by surgical or transcatheter approach, appears similarly effective and safe for males and females at intermediate surgical risk. Functional status appears to improve most in females after TAVI. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov NCT01586910.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
17.
Cardiovasc Revasc Med ; 20(2): 143-146, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-29807815

RESUMEN

BACKGROUND: Fractional flow reserve(FFR) is a validated tool for evaluating functional severity and guiding the revascularization of angiographically moderate coronary artery lesions. OBJECTIVE: To study if there is a higher frequency of positive FFR measurements in the left anterior descending(LAD) versus other major coronary arteries and also evaluate the differences in the total length of the stent placed. METHODS: A retrospective cohort study including all subjects (January 2011 to December 2015) who had fractional flow reserve (FFR) measured during coronary catheterization was conducted. Coronary catheterizations with FFR at a single tertiary care center were reviewed and FFR ≤ 0.80 post adenosine was deemed positive. The differences in the baseline characteristics and the degree of stenosis were compared between the different vessel groups. RESULTS: Of the 758 vessels included in the analysis, the majority were LAD(51.3%) followed by right coronary artery(RCA)(22.8%), Circumflex(22.2%), Left main(2.2%), and Ramus intermedius(1.5%). 25.1% of 758 vessels were FFR positive. The proportion of positive FFR were higher among LAD versus other vessels(33.2%vs.16.5%,p < 0.001), while no differences were noted between RCA and circumflex(p = 0.87) or other vessels excluding LAD(p = 0.69). Of 175 patients who received stents, no statistical difference was noted in the median[range] total length of the stent between LAD(22[9-64]) and the other coronary arteries (18[8-42])(p = 0.19). In patients with an FFR <0.75, we found that the stent length(median [range]) was significantly longer in LAD(28[9-42]) than the other coronary arteries(18[8-42])(p = 0.03). CONCLUSION: In our study, FFR was almost twice as likely to be positive in the LAD when compared to other major coronary arteries. Furthermore, there was a trend towards FFR positive LAD lesions needing longer stents than other coronary arteries. This data should encourage operators to evaluate moderate, long lesions in the LAD with FFR, as they have a higher probability of functional significance.


Asunto(s)
Cateterismo Cardíaco , Enfermedad de la Arteria Coronaria/diagnóstico , Estenosis Coronaria/diagnóstico , Vasos Coronarios/fisiopatología , Reserva del Flujo Fraccional Miocárdico , Anciano , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/fisiopatología , Estenosis Coronaria/terapia , Bases de Datos Factuales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/instrumentación , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Stents , Resultado del Tratamiento
18.
Proc (Bayl Univ Med Cent) ; 32(3): 387-389, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31384194

RESUMEN

Described herein is a 63-year-old man who developed methicillin-sensitive Staphylococcus aureus endocarditis on a previously anatomically normal mitral valve. The resulting vegetations were so large that severe mitral stenosis resulted. The development of valve stenosis due exclusively to infective endocarditis is extremely rare.

19.
J Investig Med ; 67(6): 943-949, 2019 08.
Artículo en Inglés | MEDLINE | ID: mdl-30659091

RESUMEN

Recurrent hospitalizations are common in longitudinal studies; however, many forms of cumulative event analyses assume recurrent events are independent. We explore the presence of event dependence when readmissions are spaced apart by at least 30 and 60 days. We set up a comparative framework with the assumption that patients with emergency percutaneous coronary intervention (PCI) will be at higher risk for recurrent cardiovascular readmissions than those with elective procedures. A retrospective study of patients who underwent PCI (January 2008-December 2012) with their follow-up information obtained from a regional database for hospitalization was conducted. Conditional gap time (CG), frailty gamma (FG) and conditional frailty models (CFM) were constructed to evaluate the dependence of events. Relative bias (%RB) in point estimates using CFM as the reference was calculated for comparison of the models. Among 4380 patients, emergent cases were at higher risk as compared with elective cases for recurrent events in different statistical models and time-spaced data sets, but the magnitude of HRs varied across the models (adjusted HR [95% CI]: all readmissions [unstructured data]-CG 1.16 [1.09 to 1.22], FG 1.45 [1.33 to 1.57], CFM 1.24 [1.16 to 1.32]; 30-day spaced-CG1.14 [1.08 to 1.21], FG 1.28 [1.17 to 1.39], CFM 1.17 [1.10 to 1.26]; and 60-day spaced-CG 1.14 [1.07 to 1.22], FG 1.23 [1.13 to 1.34] CFM 1.18 [1.09 to 1.26]). For all of the time-spaced readmissions, we found that the values of %RB were closer to the conditional models, suggesting that event dependence dominated the data despite attempts to create independence by increasing the space in time between admissions. Our analysis showed that independent of the intercurrent event duration, prior events have an influence on future events. Hence, event dependence should be accounted for when analyzing recurrent events and challenges contemporary methods for such analysis.


Asunto(s)
Readmisión del Paciente , Intervención Coronaria Percutánea , Sesgo , Intervalos de Confianza , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Biológicos
20.
Am J Cardiol ; 123(8): 1314-1320, 2019 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-30704670

RESUMEN

This study was performed to investigate the prevalence and impact on survival of baseline mitral stenosis (MS) in patients who underwent transcatheter aortic valve implantation (TAVI) due to the presence of severe symptomatic aortic stenosis. This retrospective study included 928 consecutive patients with severe, symptomatic aortic stenosis who underwent TAVI in 2 institutions, from January 2012 to August 2016. Mean follow-up was 40.8 ± 13.9 months. Based on the mean mitral gradient (MMG) at baseline, 3 groups were identified: MMG <5 mm Hg (n = 737, 81.7%); MMG ≥5 and <10 mm Hg (n = 147, 16.3%); MMG ≥10 mm Hg (n = 17, 1.9%). These latter were more frequently women, with a smaller body surface area, a higher prevalence of atrial fibrillation, chronic obstructive pulmonary disease, and previous history of coronary-artery bypass graft/percutaneous coronary intervention. At baseline, patients with MMG ≥10 mm Hg compared with ≥5 and <10 mm Hg and <5 mm Hg patients had a lower mitral valve area (2.4 ± 0.94 vs 2.1 ± 0.86 vs 1.5 ± 0.44 cm2), a lower prevalence of MR ≥2+ (5.9% vs 28.6% and 15.6%, p <0.0001), a higher prevalence of severe mitral annular calcium (70.6% vs 45.6% and 13.0%, p <0.0001) and a higher systolic pulmonary arterial pressure (50.6 ± 12.1 vs 47.2 ± 14.5 and 41.6 ± 14.4, p <0.0001). Despite the low prevalence of MMG ≥10 mm Hg, these patients had higher 5-year mortality compared with the other groups (adjusted hazard ratio 2.91, 95% confidence interval 1.17 to 7.20, p = 0.02). In conclusion, severe calcific MS is uncommon in patients who underwent TAVI. Its presence is associated with higher long-term mortality whereas moderate MS is not.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Mitral/etiología , Válvula Mitral/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter , Función Ventricular Izquierda/fisiología , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Cateterismo Cardíaco , Ecocardiografía , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estenosis de la Válvula Mitral/epidemiología , Prevalencia , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Tasa de Supervivencia/tendencias , Texas/epidemiología , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA