Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Eur Radiol ; 19(1): 110-20, 2009 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-18704438

RESUMEN

The purpose of this paper is to present a pulse sequence optimized to visualize human peripheral vessels. The optimized MR technique is a 3D multi-shot balanced non-SSFP gradient echo pulse sequence with fat suppression. Several imaging parameters were adjusted to find the best compromise between the contrast of vascular structures and muscle, fat, and bone. Most of the optimization was performed in the knee and calf regions using multi-channel SENSE coils. To verify potential clinical use, images of both healthy volunteers and volunteers with varicose veins were produced. The balanced non-SSFP sequence can produce high-spatial-resolution images of the human peripheral vessels without the need for an intravenous contrast agent. Both arteries and veins are displayed along with other body fluids. Due to the high spatial resolution of the axial plane source or reconstructed images, the need for procedures to separate arteries from veins is limited. We demonstrate that high signals from synovial joint fluid and cystic structures can be suppressed by applying an inversion prepulse but at the expense of reduced image signal-to-noise and overall image quality.


Asunto(s)
Algoritmos , Vasos Sanguíneos/patología , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Angiografía por Resonancia Magnética/métodos , Várices/patología , Adulto , Medios de Contraste , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
2.
Eur Radiol ; 17(9): 2294-301, 2007 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-17483955

RESUMEN

The aim was to compare bowel distension and diagnostic properties of magnetic resonance imaging of the small bowel with oral contrast (MRI per OS) with magnetic resonance enteroclysis (MRE). Forty patients with suspected Crohn's disease (CD) were examined with both MRI methods. MRI per OS was performed with a 6% mannitol solution and MRE with nasojejunal intubation and a polyethylenglycol solution. MRI protocol consisted of balanced fast field echo (B-FFE), T2 and T1 sequences with and without gadolinium. Two experienced radiologists individually evaluated bowel distension and pathological findings including wall thickness (BWT), contrast enhancement (BWE), ulcer (BWU), stenosis (BWS) and edema (EDM). The diameter of the small bowel was smaller with MRI per OS than with MRE (difference jejunum: 0.55 cm, p < 0.001; ileum: 0.35 cm, p < 0.001, terminal ileum: 0.09 cm, p = 0.08). However, CD was diagnosed with high diagnostic accuracy (sensitivity, specificity, positive and negative predictive values: MRI per OS 88%, 89%, 89%, 89%; MRE 88%, 84%, 82%, 89%) and inter-observer agreement (MRI per OS k = 0.95; MRE k = 1). In conclusion, bowel distension was inferior in MRI per OS compared to MRE. However, both methods diagnosed CD with a high diagnostic accuracy and reproducibility.


Asunto(s)
Enfermedad de Crohn/diagnóstico , Intestino Delgado , Imagen por Resonancia Magnética/métodos , Administración Oral , Adolescente , Adulto , Medios de Contraste/administración & dosificación , Femenino , Humanos , Intubación Gastrointestinal , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Eur Radiol ; 13(6): 1423-7, 2003 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-12764661

RESUMEN

Our purpose was to compare the quality of ureteral imaging in pediatric patients using two different MR sequences: the non-enhanced heavily T2-weighted (W) turbo spin-echo sequence (TSE) and the gadolinium-enhanced T1W fast-field-echo sequence (T1 FFE). An experimental study on three pigs was first performed. The TSE, before and after furosemide injection, was followed by the T1 FFE sequence. The clinical study included 11 infants and 10 children. With some modifications the same MR parameters and techniques were used as in the animal study. The TSE with TR 8000 ms and TE 650 ms implied 6 radial stacks each of 40 mm thickness. The T1 FFE included TR 18 ms, TE 2.9 ms, flip angle 60, and 50 slices with thickness 0.7 mm. After post-processing, image reconstructions qualitative and quantitative analysis were performed. Complete visualization of the ureters was achieved in 35 of 42 (83%) cases. Seventy-four percent of the ureters were completely visualized with T1 FFE compared with only 19% with TSE. Sixty-nine percent of the ureters were better imaged with T1 FFE than TSE and 21% equally well imaged. Four ureters (10%), either obstructed or due to poor renal function, were better imaged with TSE. The two sequences are complementary. Visualization of non-obstructed ureters is excellent with T1 FFE and the sequence is superior to TSE. The TSE, however, may be equal to or even better than T1 FFE in visualizing obstructed ureters or ureters draining malfunctioning kidneys.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Uréter/anatomía & histología , Obstrucción Ureteral/diagnóstico , Animales , Niño , Medios de Contraste , Diuréticos , Femenino , Furosemida , Gadolinio DTPA , Humanos , Procesamiento de Imagen Asistido por Computador , Lactante , Masculino , Porcinos , Micción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA