Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
J Arthroplasty ; 39(8S1): S130-S136.e2, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38604282

RESUMEN

BACKGROUND: Wearable sensors and associated supporting technologies (ie, patient applications) can provide both objective (joint position, step counts, etc.) and subjective data (ie, pain scores and patient-reported outcome measures) to track a patient's episode of care. Establishing a subjective and objective baseline of a patient's experience may arguably be beneficial for multiple reasons, including setting recovery expectations for the patient and demonstrating the effectiveness or success of the intervention. METHODS: In this pilot study, we characterized a subset of patients (n = 82 from 7 surgeons) using a wearable sensor system at least 6 days before total knee arthroplasty and provided postsurgical data up to 50 days postintervention. The 5-day average before surgery for total step counts (activity), achieved flexion and extension on a progress test (functional limit) and visual analog scale daily pain score were calculated. The difference from baseline was then calculated for each patient for each day postsurgery and reported as averages. RESULTS: On average, a patient will experience a relative deficit of 4,000 steps immediately following surgery that will return to near-baseline levels 50 days postintervention. A 30° deficit in flexion and a 10° deficit in extension will return at a similar rate as steps. Relative pain scores will worsen with an increase of approximately 3 points immediately following surgery. However, pain will decrease by 2 points relative to baseline between 40 and 50 days. CONCLUSIONS: The results of this pilot study demonstrate a method to baseline a patient's presurgical subjective and objective data and to provide a reference for postsurgical recovery expectations. Applications for these data include benchmarking for evaluating intervention success as well as setting patient expectations.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Medición de Resultados Informados por el Paciente , Dispositivos Electrónicos Vestibles , Humanos , Artroplastia de Reemplazo de Rodilla/instrumentación , Proyectos Piloto , Masculino , Femenino , Anciano , Persona de Mediana Edad , Rango del Movimiento Articular , Articulación de la Rodilla/cirugía , Articulación de la Rodilla/fisiopatología , Dimensión del Dolor , Recuperación de la Función
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA