Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Radiol Prot ; 42(3)2022 07 19.
Artículo en Inglés | MEDLINE | ID: mdl-35705021

RESUMEN

In Japan, the radiation-dose limit for the lens of the eye was revised in April 2021. Consequently, for workers, the numerical values of the equivalent dose to the lens of the eye are equal to those of the effective dose. Radiation workers, radiation safety officers and licensees must comply with regulations related to radiation protection and optimize protection. The new guidelines on dose monitoring of the lens of the eye developed by the Japan Health Physics Society recommend for the dose to be estimated near the eye for accurate estimation, when the dose to the lens approaches or exceeds the management criteria. However, there is limited information regarding the non-uniform exposure of nuclear power plant workers. In this study, the dose equivalents of high-dose-rate workplaces and the personal doses of 88 workers were estimated at four Japanese commercial nuclear power plant sites (RWR: 3 units and BWR: 3 units) and the dose to the lens of the eye and the exposure situations of the workers were analyzed.


Asunto(s)
Cristalino , Exposición Profesional , Exposición a la Radiación , Humanos , Japón , Plantas de Energía Nuclear , Exposición Profesional/análisis , Dosis de Radiación , Exposición a la Radiación/análisis
2.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 75(10): 1141-1149, 2019.
Artículo en Japonés | MEDLINE | ID: mdl-31631107

RESUMEN

PURPOSE: Ichihara et al. (Fujita Med J 2015; 1(1): 9-14) developed a method to simultaneously obtain both coronary computed tomography (CT) angiography and CT myocardial perfusion (CTP) using 64-multi detector CT (MDCT). An input-function (time enhancement curve, TEC) of the ascending aorta (Ao) and myocardial CT density are necessary to calculate absolute myocardial blood flow (ml/g/min) using a two-compartment model. Helical scan starting timing is important to capture the peak (P) of Ao time enhancement curve (TEC). The purpose is to search the optimal timing of starting helical scan to capture the P. METHODS: We performed 14 CTPs using Definition AS+ (SIEMENS). A dynamic scan at the Ao level was started at 7 s after contrast injection and helical scan was started at various trigger on bolus tracking. Definition AS+ needs 2 s (other scanner may need 4 s) for changing from a dynamic to helical scan mode. We created TECs of pulmonary artery (PA) and Ao using the fifth function fitting. We measured the time from trigger point to the P (t200, t250, t300 and tCP). RESULTS: Mean t200, t250, t300 and tCP were 9.1±1.9, 7.9±2.0, 6.6±1.9 and 3.9±1.2 s, respectively. In additional other 16 CTP studies using the cross point method, we can capture the P in all (100%) examinations. CONCLUSION: Scan starting at the cross point is best for Definition AS+, and the Ao=300 HU may be best for other scanner that needs 4 s for changing scan mode to obtain a fine input function for calculating absolute myocardial blood flow.


Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste , Angiografía Coronaria , Tomografía Computarizada Espiral , Tomografía Computarizada Multidetector , Cintigrafía , Factores de Tiempo , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA