Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Vasc Surg ; 78(4): 954-962.e2, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37330149

RESUMEN

OBJECTIVE: The study reports retrospective evaluation of early outcomes from a multicentric experience with the Excluder conformable endograft with active control system (CEXC Device) in the treatment of abdominal aortic aneurysms. Its design allows more flexibility, given by proximal unconnected stent rows and a bending wire within the delivery catheter enables control of proximal angulation. This study specifically focuses on the severe neck angulation (SNA) subgroup (≥60°). METHODS: All patients treated with CEXC Device in nine vascular surgery centers of Triveneto area (Northeast Italy) between January 2019 and July 2022 were enrolled prospectively and analyzed retrospectively. Demographic and aortic anatomical characteristics were evaluated. Endovascular aneurysm repair in SNA were selected for analysis. Major investigated outcomes were technical success, endoleaks, morbidity, mortality, and reinterventions at 30 days and during follow-up. Endograft migration and postoperative aortic neck angulation changes were also analyzed. RESULTS: A total of 129 patients were enrolled. An infrarenal angle of ≥60° was observed in 56 patients (43%) (SNA group) and their data analyzed. The mean patient age was 78.9 ± 5.9 years and median abdominal aortic aneurysm diameter 59 mm (range, 45-94 mm). Median aortic infrarenal neck length, angulation and diameter were 22 mm (range, 13-58 mm), 77° (range, 60°-150°), and 22.0 ± 3.5 mm respectively. Analysis revealed a technical success rate of 100% and perioperative major complication rate of 1.7%. Intraoperative and perioperative morbidity and mortality rates were 3.5% (one buttock claudication and one inguinal surgical cutdown) and 0%, respectively. No perioperative type I endoleaks were observed. The median follow-up was 13 months (range, 1-40 months). Five patients died during follow-up from aneurysm-unrelated causes. Two reinterventions occurred (3.5%): one conversion for a type IA endoleak and one sac embolization for a type II endoleak. Aneurysm sac shrinkage was observed in 15 patients (26%) and aneurysm stability in 35 patients (62%), respectively. Estimated freedom from reinterventions at 24 months was 92%. Aortic neck median postoperative angulation was 75° (range, 45°-139°). CONCLUSIONS: The Triveneto Conformable Registry shows good early results of the CEXC device in severely angulated aortic infrarenal necks. These data need confirmation on longer follow-up and a wider cohort of patients to further increase endovascular aneurysm repair eligibility in SNA.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Humanos , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/complicaciones , Endofuga/etiología , Endofuga/cirugía , Prótesis Vascular/efectos adversos , Estudios Retrospectivos , Resultado del Tratamiento , Stents/efectos adversos , Aorta Abdominal/cirugía , Sistema de Registros , Diseño de Prótesis
2.
J Endovasc Ther ; 29(2): 283-288, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-34369168

RESUMEN

PURPOSE: We describe the feasibility and early results of iliac stenting using a physician-modified endograft (PMEG) to preserve a transplant renal artery in patient with iliac occlusive disease. CASE REPORT: A 70-year-old male patient, with sub-occlusive left common iliac artery stenosis at the level of the transplanted kidney arterial anastomosis, presented with left critical limb ischemia (CLI) and pseudo-transplant renal artery stenosis (pseudo-TRAS) symptoms. He was treated with a physician-modified fenestrated covered stent introduced percutaneously via ipsilateral femoral artery after failure of simple angioplasty (percutaneous transluminal angioplasty, PTA). The modified graft was created by performing a square fenestration graftotomy on a Medtronic iliac limb stent graft (Medtronic Cardiovascular, Santa Rosa, CA, USA). The procedure was technically successful with no intraoperative complications. Procedural time was 110 minutes, including 35 minutes for device modification. On short-term follow-up, the patient had early improvement of renal function and resolution of CLI. The iliac and transplant renal artery remained patent with no sign of stent migration or kinking on 6 months surveillance computed tomography angiography and 1 year color Doppler ultrasonography. CONCLUSION: Use of PMEG to preserve visceral branches in occlusive iliac disease is a feasible endovascular technique with encouraging technical success and satisfying early results.


Asunto(s)
Arteriopatías Oclusivas , Procedimientos Endovasculares , Médicos , Anciano , Procedimientos Endovasculares/efectos adversos , Humanos , Arteria Ilíaca/diagnóstico por imagen , Arteria Ilíaca/cirugía , Masculino , Arteria Renal , Stents , Resultado del Tratamiento
3.
Vascular ; : 17085381221128058, 2022 Sep 17.
Artículo en Inglés | MEDLINE | ID: mdl-36120869

RESUMEN

OBJECTIVE: Subclavian artery aneurysms (SAA) are rare and usually involve the proximal segment of the artery. In this setting traditional surgical treatment or hybrid procedures are associated with significative morbidity rate so that new endovascular solutions are preferred. METHODS: Authors report a case of a patient with an intrathoracic left SAA involving the aortic arch's outer curve. Patient's comorbidities contraindicated open surgical treatment while anatomical issues were not favourable to hybrid or standard endovascular solutions. Thus a single-branched custom-made thoracic stent-graft (Castor, MicroPort Medical, Shanghai, China) was implanted. RESULTS: Technical success was achieved with no intra-operative complications and technical steps of the procedure are accurately described.A pre-discharge CT scan showed the correct position of the endograft, complete aneurysm exclusion and branch patency. CONCLUSION: Single-branched thoracic stentgrafts could be a good option in unfavourable anatomies with supra-aortic vessels disease involving the aortic arch, with good results in terms of morbidity and early outcomes.

4.
Vascular ; 29(2): 183-189, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32869729

RESUMEN

OBJECTIVES: Endovascular procedures are now the standard of care for endovascular aortic aneurysm repair but treatment of hostile proximal neck anatomy is still challenging. New endografts were brought to the market specifically designed to accommodate severe neck angulation. Authors describe a preliminary experience and early results using the Gore Excluder Conformable endograft (W. L. Gore & Associates, Flagstaff, Ariz) and its active control system in severe neck angulation with a standardized technical approach to achieve precise deployment in this hostile anatomy. METHODS: From June 2019 to May 2020, five patients with abdominal aortic aneurysm and severe neck angulation (≥70°) were treated with the Gore Excluder Conformable endograft at two different centers. Deployment of this endograft in this kind of anatomy should be aggressive starting over the level of renal arteries due to risk of distal migration downward on the external curvature and difficulty in upward repositioning. Authors suggested a standard technique with a routine through-and-through axillary-femoral approach, using a floppy guidewire together with preventive cannulation of the lower renal artery if a short neck (<15 mm) is associated. RESULTS: Endovascular aortic procedures were successfully completed in all patients. Final deployment of the stent graft using our standardized technical approach was extremely precise in all cases even if redeployment of the graft was necessary in all cases. No other secondary procedures were needed. At 30 days, no type IA endoleak was recorded and no aneurysm-related secondary procedures were performed. Median follow-up for this group of patients was 5.2 months (range 1-11). Early results revealed no type IA endoleak and no migration at Ct angiogram. No aneurysm-related secondary procedures were required. CONCLUSION: Routine use of through-and-through axillary-femoral guidewire associated with selective pre-cannulation of the lower renal artery allows a precise deployment of the Gore Excluder Conformable endograft in difficult anatomies possibly affecting early outcomes.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Italia , Masculino , Diseño de Prótesis , Estudios Retrospectivos , Resultado del Tratamiento
5.
Ann Vasc Surg ; 68: 553-558, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32474147

RESUMEN

OBJECTIVES: To describe a new technique based on a different deployment of the Endurant Stent-Graft System (Medtronic Cardiovascular, Santa Rosa, CA) during endovascular aortic aneurysm repair to guarantee a more precise deployment in presence of severe neck angulation (SNA). TECHNIQUE: The "step-by-step" deployment technique consists of an alternate partial release of the main body and of the free-flow suprarenal stents to approximate the radiopaque markers of the graft fabric to the aortic wall, obtaining a more precise delivery, reducing the possibility of downward dislodgments along the external curve of the infrarenal angle and asymmetrical deployments in presence of SNA. CONCLUSIONS: The "step-by-step" technique is a simple, safe, and effective graft-deployment method, which allows a very precise release in SNA and possibly achieves better results in the long-term period in such difficult anatomies.


Asunto(s)
Aneurisma de la Aorta/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Aneurisma de la Aorta/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Complicaciones Posoperatorias/etiología , Diseño de Prótesis , Factores de Riesgo , Resultado del Tratamiento
6.
Ann Vasc Surg ; 52: 57-66, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-29778608

RESUMEN

BACKGROUND: This study aims at evaluating technical success and long-term results using Gore Excluder/C3 endoprosthesis in patients with narrow aortic bifurcation (NAB; inner aortic diameter < 18 mm). METHODS: Clinical and anatomical data were collected retrospectively from patients treated in 2 high-volume Italian vascular centers between 2005 and 2017. A total of 1325 endovascular aneurysm repair procedures were performed, of which 195 involved Excluder/C3 Gore endoprosthesis. One hundred forty-one patients had a regular aortic bifurcation (RAB; maximum inner diameter ≥ 18 mm), whereas 54 presented with NAB (<18 mm). Technical success and procedural time were considered as primary outcomes. Secondary outcomes were perioperative complications, long-term graft-related complications and reintervention rates. RESULTS: Demographic data and risk factors were similar in the 2 groups. The mean diameter of aortic bifurcation was 29.8 ± 10.4 mm in RAB versus 17.1 ± 0.9 mm in NAB. Technical success was 100% in both groups. Incidence of intraoperative kinking/stenosis of limb graft was significantly higher in NAB (40.7% vs. 12.8%; P < 0.001), which was treated by means of kissing balloon technique (KiBaTe) and selective stenting. Time of procedure was similar. Post-operative complications rate was similar in both the groups (9.5% in RAB versus 4.2% in NAB, P = 0.180). Mean follow-up period was 40.0 months (range, 1-130). No significant difference was registered in long-term graft-related complications between RAB and NAB (38.3% vs. 38.8%; P = 0.939). Reintervention rate after 70 months was 21.8% vs. 24.6% in RAB and NAB, respectively (log rank = 0.517). Primary patency at 6, 12, and 48 months was 99.3% vs. 100%, 99.3% vs. 100%, and 98.5% vs. 97.9%, respectively (log rank = 0.497). Assisted primary patency was 98.6% vs. 96.0%, 97.8% vs. 96.0%, and 97.8% vs. 96.0%, respectively (log rank = 0.789). Secondary patency was 100% in both the groups. CONCLUSIONS: Endovascular aneurysm repair of NAB using Gore Excluder/C3 graft can be considered safe and effective in early and late follow-up. Intraoperative graft kinking is frequent in NAB and KiBaTe is recommended to prevent occlusive complications.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/epidemiología , Aneurisma de la Aorta Abdominal/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Incidencia , Italia/epidemiología , Masculino , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Retratamiento , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
7.
Vasc Endovascular Surg ; 58(6): 645-650, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38335135

RESUMEN

OBJECTIVE: Static 3-dimensional (3D) printing became attractive for operative planning in cases that involve difficult anatomy. An interactive (low cost, fast) 3D print allowing deliberate surgical practice can be used to improve interventional simulation and planning. BACKGROUND: Endovascular treatment of complex aortic aneurysms is technically challenging, especially in case of narrow aortic lumen or significant aortic angulation (hostile anatomy). The risk of complications such as graft kinking and target vessel occlusion is difficult to assess based solely on traditional software measuring methods and remain highly dependent on surgeon skills and expertise. METHODS: A patient with juxtarenal AAA with hostile anatomy had a 3-dimensional printed model constructed preoperatively according to computed tomography images. Endovascular graft implantation in the 3D printed aorta with a standard T-Branch Cook (Cook® Medical, Bloomington, IN, USA) was performed preoperatively in the simulation laboratory enabling optimized feasibility, surgical planning and intraoperative decision making. RESULTS: The 3D printed aortic model proved to be radio-opaque and allowed simulation of branched endovascular aortic repair (BREVAR). The assessment of intervention feasibility, as well as optimal branch position and orientation was found to be useful for surgeon confidence and the actual intervention in the patient. There was a remarkable agreement between the 3D printed model and both CT and X-ray angiographic images. Although the technical success was achieved as planned, a previously deployed renal stent caused unexpected difficulty in advancing the renal stent, which was not observed in the 3D model simulation. CONCLUSION: The 3D printed aortic models can be useful for determining feasibility, optimizing planning and intraoperative decision making in hostile anatomy improving the outcome. Despite already offering satisfying accuracy at present, further advancements could enhance the 3D model capability to replicate minor anatomical deformities and variations in tissue density.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Impresión Tridimensional , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía , Prótesis Vascular , Implantación de Prótesis Vascular/instrumentación , Toma de Decisiones Clínicas , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/instrumentación , Modelos Cardiovasculares , Modelación Específica para el Paciente , Valor Predictivo de las Pruebas , Diseño de Prótesis , Stents , Cirugía Asistida por Computador , Resultado del Tratamiento
8.
J Vasc Surg ; 57(4): 1006-13, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23343667

RESUMEN

OBJECTIVE: The goal of this article is to report the preliminary results of infrapopliteal percutaneous transluminal angioplasty stenting with the Nile Croco coronary bifurcated stent (Minvasys, Gennevilliers, France) for selected patients with critical limb ischemia (CLI). METHODS: From October 2006 to December 2010, 31 patients with CLI with below-the-knee TransAtlantic Inter-Society Consensus C and D lesions at the popliteal (n = 17, 54.8%) and distal tibioperoneal trunk (n = 14, 45.2%) bifurcations, with suboptimal primary percutaneous transluminal angioplasty results (residual stenosis >30%, elastic recoiling, or dissection), with at least two-vessel runoff to the foot (present or after percutaneous transluminal angioplasty), free of aortoiliac arterial disease, and at high surgical risk (more than three risk factors) were treated with the Nile Croco coronary bifurcated stent. Study end points included technical success, immediate and midterm primary and secondary patency rates, clinical improvement, and limb salvage. RESULTS: Technical success was achieved in all patients (100%) without any intraoperative complications. Early complications included an acute stent occlusion and an acute compartment syndrome for a collateral arterial branch perforation. Median follow-up was 12.1 months (range, 1-32). Primary and secondary patency rates were 96.7% and 86.2% (95% confidence interval [CI], 67.2%-94.6%) at 30 days and and 100% and 96.6% (95% CI, 78.0%-99.5%) at 1 year, respectively. Clinical improvement (an upward shift of at least two Rutherford categories) was achieved in 28 patients (90.3%). A major amputation was required in one patient (3.2%). The overall limb salvage rate at 1 year was 96.7% (95% CI, 78.6%-99.5%). CONCLUSIONS: Preliminary data suggest that the Nile Croco bifurcated stent for below-the-knee angioplasty in selected patients with CLI is associated with high rates of technical success, early and midterm patency, and clinical improvement. Limb salvage rates are acceptable for this technically highly challenging anatomy, yet further studies with larger patient populations are necessary to validate these results.


Asunto(s)
Angioplastia de Balón/instrumentación , Isquemia/terapia , Enfermedad Arterial Periférica/terapia , Arteria Poplítea , Stents , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/mortalidad , Enfermedad Crítica , Supervivencia sin Enfermedad , Femenino , Humanos , Isquemia/diagnóstico , Isquemia/etiología , Isquemia/mortalidad , Isquemia/fisiopatología , Estimación de Kaplan-Meier , Recuperación del Miembro , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/complicaciones , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/mortalidad , Enfermedad Arterial Periférica/fisiopatología , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Diseño de Prótesis , Radiografía , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
9.
J Endovasc Ther ; 19(4): 517-24, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22891834

RESUMEN

PURPOSE: To evaluate endovascular aneurysm repair (EVAR) of abdominal aortic aneurysms (AAA) with severe neck angulation (SNA) utilizing a thoracic endograft placed proximal to a bifurcated endograft. METHODS: A retrospective review was conducted of 28 consecutive EVAR patients (25 men; mean age 71 years, range 62-86) with proximal SNA ≥60° treated electively between December 2006 and May 2011. The average AAA neck diameter was 23 mm (range 22-28), with a mean length of 25 mm (range 10-51) and a mean maximum sac diameter of 63 mm (range 55-98). The mean neck angulation was 73° (range 60-92). All patients received an endograft designed for the thoracic aorta (Relay) placed as a proximal extension above a bifurcated abdominal aortic endograft (IntuiTrak Powerlink). RESULTS: Technical success was achieved in 100% of cases. An intraoperative type I proximal endoleak was successfully treated with stent deployment, and 2 type II endoleaks spontaneously resolved within 30 days. In all 28 patients, endograft integrity and correct positioning were confirmed at the latest imaging follow-up (mean 23.7 months, range 6-43). Fifteen (56%) aneurysm sacs were stable and 13 (46%) were reduced in size. Two patients died of unrelated causes during follow-up. CONCLUSION: The unique morphology of SNA requires the development of a precise proximal fixation technology for successful endovascular repair. This hybrid solution exploits the technological advances of the thoracic aortic endograft and the stability of an anatomically fixed bifurcated endograft. This device combination may be an alternative solution for patients with SNA who are unsuitable for traditional surgery.


Asunto(s)
Aorta Abdominal/cirugía , Aorta Torácica/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Anciano , Anciano de 80 o más Años , Aorta Abdominal/diagnóstico por imagen , Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/diagnóstico , Aortografía/métodos , Implantación de Prótesis Vascular/efectos adversos , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Italia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Diseño de Prótesis , Estudios Retrospectivos , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Ultrasonografía Doppler Dúplex
10.
J Vasc Interv Radiol ; 21(10): 1579-82, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20801682

RESUMEN

Common iliac artery (CIA) aneurysms that extend into the iliac bifurcation and internal iliac artery (IIA) usually require exclusion of the IIA, exposing pelvic ischemic complication risks. This case report presents an endovascular technique of "cross-stenting" in a short proximal landing zone with complete exclusion of the CIA aneurysm using a covered stent graft with a longer uncovered stent extending into one branch of the IIAs, maintaining full pelvic circulation. External iliac artery to IIA cross-stenting with an additional uncovered stent warrants further investigation, because it seems to extend graft stent placement indications, increase stability, and help avoid IIA exclusion.


Asunto(s)
Anastomosis Quirúrgica/instrumentación , Aneurisma de la Aorta/cirugía , Prótesis Vascular , Aneurisma Ilíaco/cirugía , Arteria Ilíaca/cirugía , Pelvis/irrigación sanguínea , Stents , Anciano , Aneurisma de la Aorta/fisiopatología , Velocidad del Flujo Sanguíneo , Circulación Colateral , Humanos , Aneurisma Ilíaco/fisiopatología , Masculino , Pelvis/fisiopatología , Resultado del Tratamiento
11.
J Vasc Surg ; 49(3): 582-8, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19135841

RESUMEN

OBJECTIVE: A retrospective analysis of immediate outcomes following aneurysm rupture (rAAA) in two groups: patients previously treated at our center with primary endovascular repair (EVAR) and patients without previous EVAR for abdominal aortic aneurysms (AAA) in an 8-year period. METHODS: Fourteen patients with a confirmed rAAA identified throughout the follow-up period following primary EVAR repair at our center (from a population of 820 AAA treated at our center in election) were retrospectively compared with 155 patients without previous EVAR in the same time period, from the introduction of an intention-to-treat protocol with EVAR for rAAA in January 1999. Primary study outcomes included 30-day mortality and severe systemic complications following rAAA correction with both open and EVAR treatments. RESULTS: In the 14 patients secondary interventions were necessary throughout follow-up prior to rupture in 43% (6/14). The mean time to rupture was 50.23 months (9-113). The mean increase in maximum aneurysmal diameter at rupture was 18.39 mm. Type of endoleaks observed at rupture: 35.7% I proximal, 35.7% III contralateral stump disconnection, 14.3% I distal, 14.3% III midgraft tear: treatment at rupture included five EVAR corrections with aortouniiliac endografts, four EVAR corrections with extensions, and five surgical conversions. Thirty-day mortality between the two groups, 28.5% (patients with prior EVAR) 38.7% (patients without prior EVAR), and severe systemic complications, 50% vs 37.6%, were not found to be statistically significant. Hemodynamic instability, 36% (patients with prior EVAR) 63% (patients without prior EVAR), was found to be an independent predictor of 30-day mortality (P < .0001), whereas severe systemic complications, 50% vs 33.5%, did not influence the same outcome (P = .852). CONCLUSIONS: In terms of mortality, it would be logical to expect a protection from the endograft in patients with previous EVAR. A trend seems to confirm this assumption, but no statistical significance was found, which may be due to the small population size.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/fisiopatología , Rotura de la Aorta/mortalidad , Rotura de la Aorta/fisiopatología , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Femenino , Hemodinámica , Mortalidad Hospitalaria , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Falla de Prótesis , Reoperación , Estudios Retrospectivos , Stents , Factores de Tiempo , Resultado del Tratamiento
12.
J Vasc Surg ; 48(4): 795-801, 2008 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-18586447

RESUMEN

OBJECTIVE: We evaluated the influence of placement of the bifurcated Powerlink endograft (Endologix Inc, Irvine, Calif) on the aortic bifurcation, with the addition of a proximal extension, in the endovascular treatment (EVAR) of selected patients with atherosclerotic abdominal aortic aneurysms (AAAs). METHODS: From September 1999 to June 2007, 205 patients were treated with the bifurcated Powerlink endograft for atherosclerotic AAA at two Italian centers with shared protocols. Patients were retrospectively divided in two groups according to treatment with the bifurcated graft only (n = 126), or its placement on the bifurcation with the addition of a proximal extension (n = 79) at the initial procedure. Study end points included postoperative complications, secondary procedures, immediate and late conversion, migration, endoleak, death, and aneurysmal sac behavior. RESULTS: Overall technical success was 98.5%. Additional procedures were performed in 18%, and postoperative complications occurred in 11.2% (systemic, 8.3%; local, 2.9%). Median follow-up was 42.4 months (range, 6-94 months). Secondary procedures were recorded in 11.2%, migration in 3.9%, type I proximal endoleak in 7.8%, and late conversions in 2.4%. Placement on the bifurcation and the addition of an extension were associated with a higher incidence of postoperative complications (7.1% vs 17.7%, P = .020). A reduced incidence of endoleak (19% vs 8.9%, P = .048), secondary procedures (14.3% vs 6.3%, P = .04), and migration (6.3% vs 0%, P = .024) were observed in the group with a proximal extension. Analysis of single variables reveals that migration was significantly influenced by placement of the graft on the bifurcation (47% vs 0%, P < .001). Both placement on the bifurcation and the addition of an extension positively influenced the type I proximal endoleak rate (3.8% vs 35.3% P < .001) and the need for a secondary intervention (6.3% vs 35.3% P < .001) Two aneurysm ruptures and five cases of late conversion occurred in the group treated with a bifurcated graft only (4%, P = .52, P = .159). Analysis of aneurysm sac behavior was not statistically significant: enlargement, 4.1% vs 1.3% (P = .158); reduction, 34.1% vs 40.5% (P = .542). CONCLUSION: The placement of the bifurcated Powerlink endograft on the aortic bifurcation with a proximal extension for complete sealing seems to improve late outcomes, particularly secondary procedures, migration, and endoleak development. Larger prospective studies with longer follow-up are necessary to confirm these promising results.


Asunto(s)
Angioplastia , Aneurisma de la Aorta Abdominal/cirugía , Aterosclerosis/cirugía , Prótesis Vascular , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/complicaciones , Enfermedades de la Aorta/complicaciones , Enfermedades de la Aorta/cirugía , Aterosclerosis/complicaciones , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo , Resultado del Tratamiento
13.
Chir Ital ; 60(1): 23-31, 2008.
Artículo en Italiano | MEDLINE | ID: mdl-18389744

RESUMEN

The association between abdominal aortic aneurysms (AAA) and cancer is becoming more and more frequent, giving rise to several questions regarding the therapeutic and surgical management strategies for both diseases. Endovascular aneurysm repair (EVAR) is the treatment of choice for complex and high-risk patients. In this study we reviewed our experience with patients concomitantly affected by any type of cancer and AAA treated by EVAR at our institution over the last six years. From April 2001 to July 2007, 497 AAA patients underwent open or endografting repair in the 1st Division of General Surgery--Service of Vascular Surgery of the University of Verona. In 53 cases (10.6%) an association with a solid neoplasm was found and 27 of these patients (50.9%) were treated by EVAR. Twenty patients underwent a two-stage approach, with EVAR performed first, while in 5 cases a one-stage approach was preferred on the basis of the general condition of the patients, the site of the tumour to be resected, the logistic possibilities and increased experience of the operators with EVAR. Two patients received chemotherapy after EVAR. There was no in-hospital mortality and four perioperative complications (14.8%) were registered. During a mean follow-up of 25.7 months (range: 2-64 months) 5 deaths occurred, 2 in the short term and 3 in the long term, none of which were related to AAA treatment. Three type-2 endoleaks occurred that sealed spontaneously and 62.9% of the treated aneurysms had a mean 20% decrease in diameter while the others presented no variations. In our experience, EVAR was a safe and effective treatment of AAA patients with concomitant malignancies with a relatively low procedure-related morbidity and no mortality. A simultaneous surgical approach can be achieved safely, performing EVAR as the first step without significant risks. Simultaneous treatment has the advantage of avoiding a second major procedure and eliminates the risk of aortic aneurysm rupture in the postoperative period or during chemotherapy in patients who are usually in poor general condition. Care must be taken with regard to the choice of the device to be used and the possible vascular complications of the visceral circulation. In our opinion, EVAR should be considered the treatment of choice in these patients, taking into account, however, that this treatment is not always feasible in all cases and that in patients with a normal life-expectancy (tumour-cured) it may not always be the right choice. Thus, a multidisciplinary approach is necessary in the individual evaluation of these challenging patients in order to make the right decisions.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/métodos , Endoscopía/métodos , Neoplasias/complicaciones , Procedimientos Quirúrgicos Vasculares/métodos , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Implantación de Prótesis Vascular/instrumentación , Terapia Combinada , Comorbilidad , Progresión de la Enfermedad , Embolización Terapéutica/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Procedimientos Quirúrgicos Mínimamente Invasivos , Neoplasias/tratamiento farmacológico , Neoplasias/cirugía , Complicaciones Posoperatorias/epidemiología , Cuidados Preoperatorios , Estudios Retrospectivos , Riesgo , Stents , Tomografía Computarizada por Rayos X , Procedimientos Quirúrgicos Vasculares/instrumentación
14.
Chir Ital ; 60(2): 273-7, 2008.
Artículo en Inglés | MEDLINE | ID: mdl-18689178

RESUMEN

Primary aortoduodenal fistula is a serious and rare complication of abdominal aortic aneurysms. This life-threatening disease results most commonly from an abdominal aortic aneurysm, with the fistula forming between the aorta and the third or the fourth portions of the duodenum. Diagnosis is often difficult and urgent adequate surgical treatment as soon as possible is the only therapeutic option to save the lives of these patients. In this paper we report the case of a 76-year-old female admitted to our institution for massive haematemesis, melaena, severe hypotension and violent back pain. The urgent diagnostic work-up revealed an abdominal aortic aneurysm with a strong suspicion of duodenal fistulisation. The diagnosis was confirmed in the operating room, where the patient was immediately submitted to closure of the fistula and in situ aortic reconstruction using an aortic homograft. The postoperative course was uneventful and after 6 months the patient is doing well without any recurrence of infection.


Asunto(s)
Aorta Abdominal , Enfermedades de la Aorta/cirugía , Enfermedades Duodenales/cirugía , Fístula Intestinal/cirugía , Fístula Vascular/cirugía , Anciano , Femenino , Humanos , Procedimientos Quirúrgicos Vasculares
15.
J Gastrointest Surg ; 11(2): 143-9, 2007 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-17390163

RESUMEN

BACKGROUND: Radio frequency ablation (RFA) of hepatocellular carcinoma has proved to be useful in local control of tumor. A few data on survival after treatment are available in literature. The aim of the study was to evaluate factors related to survival and to identify different classes of risk after radio frequency ablation. METHODS: Ninety-eight cirrhotic patients with 145 hepatocellular carcinomas were treated with radio frequency ablation from January 1998 to May 2004. In 55 patients, cirrhosis was in Child-Pugh class A, and in 43, in class B. Tumor was single in 60 and multiple in 38; mean tumor number was 1.5 (range 1-3). Tumor size ranged from 1.5 to 6.0 cm, mean 3.8 cm. Mean follow up period was 24.9 months. Radio frequency ablation was performed with expandable type needle with percutaneous approach under real-time ultrasound guidance. For statistical analysis, univariate and multivariate analysis were performed. RESULTS: Complete ablation of the tumor was achieved in 85.5% of lesions. Survival, 1 and 3 years, was 76.7 and 36.6%, respectively. Univariate analysis showed that Cancer of the Liver Italian Program (CLIP) score, tumor growth pattern, alpha-fetoprotein level, and complete tumor necrosis, were factors significantly related to poor survival. Multivariate analysis identified that factors related to poor survival were alpha-fetoprotein level >100 ng/ml, Child-Pugh class B, and incomplete tumor necrosis with a hazard ratio of 4.0, 2.7, and 3.8, respectively. After complete ablation, median survival was 38 months in patients with Child-Pugh class A cirrhosis and alpha-fetoprotein level < or =100 ng/ml, 22 months for patient with Child-Pugh class B cirrhosis and alpha-fetoprotein < or =100 ng/ml, and 9 months for patient with Child-Pugh class A cirrhosis and alpha-fetoprotein >100 ng/ml (P < 0.01). CONCLUSIONS: Complete necrosis and absence of residual tumor positively affect survival after RFA. In patients with Child-Pugh A cirrhosis and alpha-fetoprotein level < or =100 radio frequency, ablation have results, 55% after 3 years, that are comparable to those of surgical resection. Patients with Child-Pugh B cirrhosis and/or alpha-fetoprotein >100 ng/ml showed less satisfactory results, and in these patients, multimodality treatment or other treatments should be considered.


Asunto(s)
Carcinoma Hepatocelular/cirugía , Ablación por Catéter , Cirrosis Hepática/complicaciones , Neoplasias Hepáticas/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma Hepatocelular/complicaciones , Carcinoma Hepatocelular/mortalidad , Ablación por Catéter/efectos adversos , Femenino , Humanos , Neoplasias Hepáticas/complicaciones , Neoplasias Hepáticas/mortalidad , Masculino , Persona de Mediana Edad , Análisis de Supervivencia
16.
Vasc Endovascular Surg ; 51(5): 288-294, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28504077

RESUMEN

AIM: To evaluate the protective role of routine shunting in patients with acute watershed stroke (WS) undergoing carotid endarterectomy (CEA). METHODS: A total of 138 patients with symptomatic carotid stenosis (SCS) who underwent CEA after acute ischemic stroke from March 2008 to March 2015 were included in this study. Transient ischemic attacks were excluded. These patients were divided into 2 groups according to the topographic pattern of the stroke on magnetic resonance imaging: group 1, territorial strokes (TS) caused by emboli of carotid origin, and group 2, WS caused by a hemodynamic mechanism related to an SCS. Primary end points were 30-day mortality and postoperative neurological morbidity. The insertion of a Pruitt carotid shunt was performed systematically. RESULTS: Ninety (65.2%) patients presented a TS of carotid origin and were included in group 1, and 48 (34.8%) of the 138 patients had a WS related to an SCS and were included in group 2. The median time between clinical onset of the cerebral ischemic event and surgery was 9 days (range: 0-89 days). Postoperative mortality was 0%. Seven (5.1%) patients had an aggravation of the neurological status during the postoperative period, of whom 2 presented a complete regression of the symptoms in less than 1 hour (definitive postoperative neurologic morbidity: 3.6%). Postoperative neurologic morbidity rate was significantly higher in the TS group (7 of 90; 7.8%) compared to the WS group (0 of 48; P = .04). No other independent predictive factor of neurologic morbidity after CEA for an SCS was found. CONCLUSIONS: Our results suggest that routine shunting should be considered in case of acute WS since it may play a protective role. Further studies are eagerly awaited to better define the timing and the best treatment option for both acute WS and TS related to an SCS in order to reduce postoperative neurologic morbidity.


Asunto(s)
Isquemia Encefálica/etiología , Estenosis Carotídea/cirugía , Circulación Cerebrovascular , Endarterectomía Carotidea , Accidente Cerebrovascular/etiología , Anciano , Anciano de 80 o más Años , Isquemia Encefálica/diagnóstico por imagen , Isquemia Encefálica/fisiopatología , Estenosis Carotídea/complicaciones , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/fisiopatología , Bases de Datos Factuales , Endarterectomía Carotidea/efectos adversos , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Examen Neurológico , Flujo Sanguíneo Regional , Estudios Retrospectivos , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/fisiopatología , Resultado del Tratamiento
17.
Vasc Endovascular Surg ; 51(7): 493-497, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28743219

RESUMEN

PURPOSE: We report the case of a thoracic endograft used to achieve exclusion of a ruptured proximal paranastomotic abdominal aortic aneurysm (PAAA) as a consequence of aortic ballooning. CASE REPORT: A type I proximal endoleak was evidenced following endovascular repair of a PAAA with an aortic cuff. The leak was treated with ballooning, which caused distal aortic rupture. A thoracic endograft was deployed inside the cuff, achieving complete exclusion. At 1 year, there are no signs of migration or endoleak with complete PAAA thrombosis, according to computed tomographic angiography. CONCLUSION: In hostile proximal abdominal aortic neck, challenging anatomies, or urgent cases, the structural adaptability of thoracic endografts could provide safe and successful abdominal aortic endovascular exclusion.


Asunto(s)
Aorta Abdominal/cirugía , Aorta Torácica , Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Diseño de Prótesis , Stents , Enfermedad Aguda , Anciano , Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Rotura de la Aorta/diagnóstico por imagen , Aortografía/métodos , Angiografía por Tomografía Computarizada , Humanos , Masculino , Resultado del Tratamiento
18.
Hepatogastroenterology ; 53(72): 973-5, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-17153466

RESUMEN

BACKGROUND/AIMS: There are great controversies regarding the surgical management of abdominal aortic aneurysm (AAA) with coexistent gastrointestinal cancers. The aim of this study was to report our experience of AAA with concomitant gastric cancer and to compare our results with the literature. METHODOLOGY: From January 1988 to December 2002, six patients with simultaneous diagnosis of AAA and gastric cancer were operated on at the First Department of General Surgery, University of Verona, Italy. The study was completed with the review of the literature data collected by Medline search. RESULTS: The surgical treatment of the cases observed at our Institution, 2 treated by a staged procedure, 2 by synchronous surgery and 2 in which the AAA remained untreated due to the evidence of metastatic disease at laparotomy, were described. Furthermore 47 cases, previously described in literature, 21 who underwent staged surgery, 23 with a synchronous procedure and 3 in which the treatment was limited to the tumor were analyzed. CONCLUSIONS: 1) Synchronous treatment of AAA and gastric cancer is feasible, 2) it can be done with an adequate extent of gastric resection and nodal dissection in the majority of cases, 3) it has a complications rate comparable to the staged procedure.


Asunto(s)
Aneurisma de la Aorta Abdominal/complicaciones , Neoplasias Gástricas/complicaciones , Neoplasias Gástricas/cirugía , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
19.
Chir Ital ; 58(2): 247-51, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16734175

RESUMEN

Humeral neck fracture is rarely associated with injury of the nearby axillary artery and in the English literature only 29 such cases have been reported. An injury of the distal axillary artery secondary to reduction and fixation of a humeral neck fracture is a very rare and unusual complication, to the best of our knowledge has never been reported in literature. In this paper we report the case of entrapment of the distal axillary artery in the humerus rhyme fracture in a 9-year-old child who suffered a nighttime car-accident with her father. At admission, the child presented a left humeral neck fracture with no other lesions and no neurologic problems in her limb; peripheral pulses present in her left hand at palpation. After closed reduction and pinning of the fracture with 2 K-wires, the left upper limb became ischemic and pulseless and the child was transferred at our Institution for diagnosis and treatment. In this paper we discuss the treatment to be adopted in this very unusual situation.


Asunto(s)
Arteria Axilar/lesiones , Fracturas del Húmero/cirugía , Complicaciones Intraoperatorias/cirugía , Niño , Femenino , Humanos , Complicaciones Intraoperatorias/etiología , Recuperación del Miembro
20.
Chir Ital ; 57(6): 723-30, 2005.
Artículo en Italiano | MEDLINE | ID: mdl-16400767

RESUMEN

Treatment of femoral artery pseudoaneurysms includes US-guided compression, endovascular coil embolisation or stenting, thrombin injection and open surgical repair. Thrombin injection is currently the standard approach to all non-complicated pseudoaneurysms of the peripheral arteries. Between January 2001 and December 2004, 59 pseudoaneurysms of the femoral artery were submitted to percutaneous US-guided thrombin injection in our surgery division. Complicated pseudoaneurysms, patients in whom percutaneous treatment failed, and chronic pseudoaneurysms with large necks were excluded from this kind of treatment and underwent surgical repair. Eighteen patients were on therapeutic anticoagulation (30.5%) and none of the pseudoaneurysms had an associated arteriovenous fistula. All patients were submitted to clinical and ultrasound follow-up at 24 hours and at 1, 6 and 12 months, and thereafter at yearly intervals for evaluation of recurrences. The thrombin injection was successful in 57/59 patients (96.6%) while two patients (3.4%) were submitted to surgical treatment after failure of the procedure. In 1 patient (1.7%) an additional injection was necessary to achieve complete thrombosis of the pseudoaneurysm. No complications occurred; none of the patients reported discomfort and there was no request for sedation. No recurrences were seen at follow-up. Nowadays US-guided percutaneous thrombin injection is the treatment of choice for femoral artery pseudoaneurysms. Surgical treatment is reserved to rare selected cases. More studies are necessary to evaluate further indications for treatment of visceral or small distal artery pseudoaneurysms.


Asunto(s)
Aneurisma Falso/cirugía , Cateterismo Periférico , Arteria Femoral/cirugía , Hemostáticos/administración & dosificación , Trombina/administración & dosificación , Ultrasonografía Intervencional , Adulto , Anciano , Anciano de 80 o más Años , Aneurisma Falso/diagnóstico por imagen , Femenino , Arteria Femoral/diagnóstico por imagen , Estudios de Seguimiento , Humanos , Inyecciones Intralesiones , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA