Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 70
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Ann Vasc Surg ; 101: 204-208, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38307229

RESUMEN

BACKGROUND: Soft-tissue sarcomas represent approximately 1% of adult malignancies. When they involve the lower limbs (LLs) and come into contact with blood vessels, the therapeutic choice was historically a primary amputation. Today, radical surgical resection with wide margins of safety is the primary therapeutic option for multidisciplinary limb-salvage surgery. The aim was to compare the morbidity and mortality results of an oncologic resection of LL soft-tissue sarcomas with arterial replacement (AR) to that obtained with arterial subadventitial dissection (ASD). METHODS: All consecutive patients with arterial close contact soft-tissue sarcomas of LL were included. Two groups were formed: an AR group where AR was performed following surgical resection and an ASD group in which the artery in contact with the tumor was preserved by ASD. Fisher's exact test was used. RESULTS: Eighteen patients with a median age of 61.50 (interquartile range [IQR] 54.25-69.75) years underwent oncovascular surgery with orthopedic and vascular surgeons between August 2013 and May 2022. Sarcomas were all located in the thigh. Nine patients were enrolled in each of the 2 groups. The 6-month survival rate was 77.78% in the AR group and 100% in the ASD group (P = 0.4). In the AR group, 2 patients presented local recurrence, with a median recurrence-free time of 24.48 (IQR 14.08-34.87) months, and 2 patients presented distant metastases, with metastasis-free time of 13.45 (IQR 8.12-35.11) months. In the ASD group, no local recurrence was observed, and 2 patients presented metastases with a median metastasis-free time of 3.90 (IQR 3.18-4.61) months. Six patients in the AR group and 7 in the ASD group required surgical revision (P = 0.017). No major amputation was necessary. CONCLUSIONS: Oncovascular surgery for LL sarcomas with ASD is certainly more locally morbid perioperatively than that with AR but provides patients with better medium-term survival.


Asunto(s)
Procedimientos de Cirugía Plástica , Sarcoma , Neoplasias de los Tejidos Blandos , Adulto , Humanos , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Estudios Retrospectivos , Sarcoma/diagnóstico por imagen , Sarcoma/cirugía , Extremidad Inferior/irrigación sanguínea , Neoplasias de los Tejidos Blandos/patología , Recuperación del Miembro/métodos
2.
Eur J Vasc Endovasc Surg ; 66(4): 531-540, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37385368

RESUMEN

OBJECTIVE: The aim of this study was to compare the long term efficacy of lower limb bypass with that of endovascular treatment (EVT) in patients with chronic limb threatening ischaemia (CLTI). METHODS: This retrospective, multicentre study evaluated the outcomes of patients with CLTI who underwent first time infra-inguinal bypass or EVT. The primary outcome was to compare amputation free survival (AFS) rates between the two propensity score matched groups. The secondary outcome was to compare wound healing within the first six months. Major adverse events were compared according to the type of revascularisation. RESULTS: Overall, 793 patients fulfilled the eligibility criteria, from whom 236 propensity score matched pairs were analysed. The mean follow up was 52 months. The 236 bypass procedures included 190 autogenous bypass grafts (80.5%), 151 (64.0%) of which were infrapopliteal. Among the 236 EVT procedures, the target lesion was the femoropopliteal segment in 81 patients (34.3%), the femoropopliteal and infrapopliteal segments in 101 patients (42.8%), and the infrapopliteal segment in 54 patients (22.9%). AFS was significantly better in the bypass group at five years (60.5 ± 3.6%) compared with the EVT group (35.3 ± 3.6%) (p < .001). Major amputation occurred in 61 patients (25.8%) in the bypass group and 85 patients (36.0%) in the EVT group (HR 0.66, 95% CI 0.47 - 0.92; p = .014). The probability of healing was significantly better in the bypass group at six months compared with the EVT group (p = .003). The median length of stay was shorter for the EVT group (4 days) than for the bypass group (8 days) (p = .001). Urgent re-intervention and re-admission rates were high and did not differ significantly between the groups. CONCLUSION: This study has shown that lower limb bypass surgery offered a significantly higher probability of AFS and wound healing compared with EVT in patients with CLTI.

3.
Ann Vasc Surg ; 91: 28-35, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36549474

RESUMEN

BACKGROUND: To study the mortality and delays of management of patients with acute mesenteric ischemia (AMI) admitted to the emergency department of a tertiary hospital and identify risk factors for 1-month mortality. METHODS: A single-center and retrospective study including all consecutive patients treated for AMI from January 2008 to December 2018 was conducted. Short- and medium-term survival was studied with a Kaplan-Meier analysis. Delays before diagnosis and surgical intervention were collected. To determine factors associated with mortality at 1 month postoperatively, univariate and multivariate analyzes were performed. RESULTS: The survival rate of the 67 included patients was 55.22% at 1 month and 37.31% at 1 year. In-hospital mortality was 50.74%. The average delay between admission and diagnosis was 4.83 ± 5.03 hr (95% confidence interval [CI], 3.60-6.05), and the delay between admission and surgical treatment was 10.64 ± 8.80 hr (95% CI, 8.49-12.79). The independent variables associated with an increased mortality at 1 month postoperatively in the univariate analysis were age >65 years old (odds ratio [OR] = 3.52; P = 0.046), lactate >3.31 mmol/l at admission (H0) (OR = 7.38; P < 0.001), lactate >3.32 mmol/l on day 1 (H24) (OR = 5.60; P = 0.002), creatinine >95.9 µmol/l at H0 (OR = 4.66; P = 0.004), aspartate aminotransferase (AST) >59 U/l at H0 (OR = 3.55; P = 0.017), and having hypertension as comorbidity (OR = 9.32; P = 0.040). Early curative anticoagulation (z = -2.4; P = 0.016) was an independent protective factor for mortality, and lactate >3.31 mmol/l at H0 (z = 2.62; P = 0.009) was an independent predictor factor of mortality at 1 month postoperatively in the multivariate analysis. CONCLUSION: AMI remains a serious and lethal condition with delays of surgical management remaining too long due to a lack of a dedicated therapeutic protocol allowing an early diagnosis.


Asunto(s)
Isquemia Mesentérica , Humanos , Anciano , Isquemia Mesentérica/diagnóstico por imagen , Isquemia Mesentérica/terapia , Estudios Retrospectivos , Resultado del Tratamiento , Factores de Riesgo , Mortalidad Hospitalaria , Lactatos
4.
J Endovasc Ther ; 29(6): 885-892, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35012405

RESUMEN

INTRODUCTION: The purpose of this study was to evaluate the efficacy of polycystic kidney embolization, performed to reduce kidney volume before heterotopic kidney transplantation, as this technique could be an alternative to pretransplant nephrectomy. MATERIALS AND METHODS: All patients who underwent pretransplant embolization of polycystic kidneys were included in a prospective register from June 2014 to February 2020. All patients underwent computed tomography (CT) scan with volumetric reconstruction (OsiriX, Bernex, Switzerland) before embolization and were then followed up at 3 and 6 months after embolization. Primary outcome was percentage of kidney volume reduction. Secondary outcomes were 30 day mortality and morbidity. RESULTS: Thirty-one embolizations performed on 29 patients (medium age = 55.6; 62.1% male) were included between June 2014 and February 2020. All patients were under dialysis before embolization (9 peritoneal dialysis and 20 hemodialysis). Technical success was observed in 96.8% of cases. Mean procedural time was 65 minutes (range = 35-106 minutes) and mean length of in-hospital stay was 3.8 days (range = 3-6 days). A volume reduction allowing a kidney transplant was obtained for 28 patients (96.5%). The mean volume reduction was 39.9% (range = 6.01-68.2). The main observed complication was postembolization pain in 10 cases (32.2%). One patient needed complementary nephrectomy due to insufficient volume reduction. Twenty-three patients (79.3%) received renal transplant during follow-up with a mean delay of 19.5 month (range = 4-54). CONCLUSION: Polycystic kidney embolization is an effective and safe minimally invasive technique. It can be proposed as the first-choice technique for kidney transplant recipients as an alternative to pretransplantation nephrectomy.


Asunto(s)
Embolización Terapéutica , Enfermedades Renales Poliquísticas , Riñón Poliquístico Autosómico Dominante , Humanos , Masculino , Persona de Mediana Edad , Femenino , Riñón Poliquístico Autosómico Dominante/diagnóstico por imagen , Riñón Poliquístico Autosómico Dominante/terapia , Trasplante Heterotópico , Resultado del Tratamiento , Nefrectomía/métodos , Estudios Retrospectivos
5.
Ann Vasc Surg ; 83: 62-69, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-35108557

RESUMEN

BACKGROUND: Conventional open surgery is still important beside endovascular surgery in the management of abdominal aortic aneurysms, with less reinterventions in the long-term follow-up. Incisional hernias are the major complication open surgery in the mid- and long term. The occurrence of this late complication could be due to the choice of the incision, median or transverse. The objectives of our retrospective and bicentric study were to characterize the long-term risk factors for incisional hernias after open surgery for abdominal aortic aneurysms, in particular by comparing the 2 types of laparotomy, and to determine the prevalence of the operated and not operated incisional hernias. MATERIALS AND METHODS: Between January 2009 and December 2011, all the patients having elective open surgery for abdominal aortic aneurysm (AAA) by midline laparotomy at the University hospital of Besancon or by transversal laparotomy at the University Hospital of Strasbourg were included retrospectively. The demographic data, the time of diagnosis of the incisional hernia and the parietal reinterventions were collected during a 5-year postoperative follow-up. A univariate and multivariate Cox model was used for the statistical analysis to determine the long-term risk factors for the appearance of an incisional hernia. RESULTS: During the study period, 223 patients presenting with AAA were included, 112 of them were operated by a midline laparotomy and 111 by a transverse laparotomy. The mean age of the patients was 69 ± 8,4years and 208 (93.3%) were men. The 5-year prevalence of incisional hernias was 14.3% (32), and 20 of these hernias (9%) had to be operated. Eighteen hernias (16.1%) occurred after a midline laparotomy and 14 (12.6%) after a transverse incision (P = 0.30). In univariate analysis, obstructive chronic pulmonary disease was the only significant risk factor for incisional hernia (P = 0.01) and an age over 65 years appeared to protect against this risk (P = 0.049). These results were confirmed by multivariate analysis, which showed that obstructive chronic pulmonary disease was an independent risk factor for incisional hernia (HR = 2.35, 95% CI 1.16-4.75), and that an age over 65 years was a protective factor (HR = 0.49 95% IC 0.00-0.99). CONCLUSIONS: The type of laparotomy did not modify the rate of incisional hernias. We showed that only 9% of the patients had to be operated to treat an incisional hernia during the first 5 years after surgery for AAA in our bicentric study. Chronic obstructive pulmonary disease was the only independent risk factor for the occurrence of an incisional hernia.


Asunto(s)
Aneurisma de la Aorta Abdominal , Hernia Incisional , Enfermedades Pulmonares , Anciano , Aneurisma de la Aorta Abdominal/complicaciones , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Femenino , Hernia/complicaciones , Humanos , Hernia Incisional/epidemiología , Hernia Incisional/etiología , Masculino , Estudios Retrospectivos , Factores de Riesgo , Resultado del Tratamiento
6.
Int J Obes (Lond) ; 45(10): 2274-2276, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34211115

RESUMEN

This study aimed at developing scores predicting surgical complications in obese transplant recipients, based on preoperative computed tomography (CT) parameters. All consecutive patients with a body mass index (BMI) ≥ 30 kg/m2 who underwent kidney transplantation between 2012 and 2019 were included. The preoperative CT parameters were assessed: total fatty surface (TFS), subcutaneous fatty surface (SFS), iliac vessel to skin distance (VSD), and abdominal perimeter (AP). Per- and postoperative complications (vascular, urinary, parietal, and digestive complications) within 30 days were listed. Predictive models of surgical complications were generated based on the results of the logistic regression. Among the 163 patients included, 53 (32.5%) experienced surgical complications. The AP was a risk factor for complications in multivariate analysis (OR: 1.050; 95% CI: 1.016-1.087; p = 0.03). Two predictive models of complications were created based on the statistical analysis: a one-variable model based on AP (sensitivity 86.8%, specificity 41.8%, area under the curve (AUC) 65.3, with a cutoff value of 107 cm) and a five-variable model based on BMI, TFS, SFS, VSD, and AP (sensitivity 73.6%, specificity 57.3%, AUC 66.2). These models, based on patient morphometric measurements, could allow predicting the occurrence of surgical complications in obese candidates for kidney transplantation.


Asunto(s)
Toma de Decisiones , Trasplante de Riñón/métodos , Complicaciones Posoperatorias/prevención & control , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Índice de Masa Corporal , Humanos , Trasplante de Riñón/estadística & datos numéricos , Modelos Logísticos , Obesidad/complicaciones , Obesidad/epidemiología , Complicaciones Posoperatorias/epidemiología , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Tomografía Computarizada por Rayos X/métodos
7.
J Vasc Surg ; 74(2): 569-578.e3, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33592295

RESUMEN

AUTHORS' NOTE: On February 17, 2021, Medtronic Incorporated issued a global voluntary recall of the Valiant Navion Thoracic Stent Graft System (the device under study in the Valiant Evo Global Clinical Program that is the subject of this publication), and instructed physicians to immediately cease use of the Valiant Navion system and return any unused product. Medtronic initiated the recall in response to three clinical trial subjects recently observed with stent fractures, two of whom have confirmed type IIIb endoleaks. The data collection, analysis, and manuscript submission occurred before the notice of this recall, and, specifically, the 100 procedures reviewed for this series were free of events at 1 year related to the reason for this device recall. The authors of this article and the manufacturer were unaware of the recently detected adverse events at the time of the preparation of the manuscript, and the 1-year trial results, and imaging-based analyses described are unchanged. Management of thoracic aortic aneurysms continues to be a challenging problem and outcomes are dependent on patient anatomy. The present publication focuses on the importance of achieving proximal and distal seals and the consideration of the temporal changes of the aortic morphology as a part of the TEVAR planning process. The authors believe there is still scientific merit in disclosing this information, despite the current nonavailability of the Valiant Navion system. OBJECTIVE: The Valiant Navion stent graft system (Medtronic Inc, Santa Rosa, Calif) is a third-generation device with improved conformability. We have reported the 1-year clinical trial outcomes, with a focus on an imaging-based analysis of the aortic morphology. We assessed the effects of graft implantation on the native anatomy and the effects of the 1-year changes in thoracic aorta morphology on the original seal zones of the stent graft. METHODS: A total of 100 subjects were enrolled in a prospective single-arm clinical trial investigating the Valiant Navion stent graft system. An independent core laboratory (Syntactx, New York, NY) assessed the anatomic characteristics and performance outcomes. RESULTS: Through 1 year of follow-up, the freedom from all-cause mortality, aneurysm-related mortality, and secondary procedures was 89.8%, 97.0%, and 94.8% respectively. Of the 100 patients, 5 had undergone a total of six secondary procedures, and 9 patients had developed an endoleak (type Ia and Ib in 1, type Ia in 1, type Ib in 3, and type II in 4 patients) within the first year. After 1 year, 2 of 76 patients (2.6%) had had an increase in their maximum aneurysm diameter of ≥5 mm, 62 (81.6%) had had stable sacs, and 12 (15.8%) had experienced sac shrinkage. Although no deployment failures had occurred, 36 of the 100 proximal (36%) and 31 of the 100 distal (31%) attachment zones were considered short according to our definitions. The stent graft had conformed to the native anatomy at implantation, because the preprocedural thoracic aorta tortuosity (1.45 ± 0.02) had not significantly changed at 1 month after implantation (1.46 ± 0.02). Despite a natural increase in thoracic tortuosity after 1 year (1.49 ± 0.02), wall apposition had been maintained over time, as evidenced by the low endoleak rates. Aortic elongation and dilation had occurred at the proximal end of the graft by an average of 1.2 mm and 1.6 mm, respectively. Aortic remodeling was more pronounced at the distal end, with an average increase of 4.2 mm in length and 2.8 mm in diameter. CONCLUSIONS: The included patients had had positive 1-year outcomes with high freedom from mortality, endoleak development, and secondary procedures. Aortic elongation and dilation were more prevalent at the distal end, emphasizing the importance of distal attachment zone consideration as part of preoperative planning. Because aortic remodeling can be expected to continue over time, additional follow-up and imaging analysis in the trial will be necessary to assess the aortic morphology and its effects on stent graft performance.


Asunto(s)
Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Aorta Torácica/diagnóstico por imagen , Aorta Torácica/fisiopatología , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/fisiopatología , Aortografía , Implantación de Prótesis Vascular/efectos adversos , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/cirugía , Estudios Prospectivos , Diseño de Prótesis , Reoperación , Factores de Tiempo , Resultado del Tratamiento , Remodelación Vascular
8.
Ann Vasc Surg ; 72: 72-78, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32479878

RESUMEN

BACKGROUND: Sarcopenia is a factor of poor prognosis for patients with critical limb threatening ischemia (CLTI), but its diagnosis requires imaging measurements and is time consuming. We investigated whether preoperative platelet-to-lymphocyte ratio (PLR) could be an easy and rapid marker of sarcopenia. METHODS: Patients treated for CLTI between January 2019 and July 2019 were included in this single-center retrospective study. Sarcopenia was defined by a psoas muscle index (PMI) <5.5 cm2/m2 in men, and <4.0 cm2/m2 in women. PLR was calculated for all patients based on their systematic preoperative blood analysis. The diagnostic power of PLR was analyzed through a receiver operating characteristic (ROC) curve. Early outcomes of sarcopenic patients in terms of 30-day mortality and 30-day morbidity were retrieved. RESULTS: Sixty-four patients were included in the study: 48 nonsarcopenic patients (mean PMI 7.34 cm2/m2; interquartile range [IQR] 6.58-8.01) and 16 sarcopenic patients (mean PMI 4.30 cm2/m2; IQR 3.45-5.17). No difference was found between both groups regarding patient demographics, clinical characteristics, cardiovascular risk factors, comorbidities, or revascularization modalities. PLR was significantly higher in the sarcopenic group (mean 332.1; IQR 158.2-320.7) compared with the nonsarcopenic group (mean 204.6; IQR 133.8-265.6) (P = 0.02). A PLR value ≥292.5 was shown to be a diagnostic marker for sarcopenia based on the ROC curve (sensitivity 31.3%, specificity 91.7%). Thirty-day mortality was 12.5% in the sarcopenic group and 2.1% in the nonsarcopenic group (P = 0.15); 30-day morbidity was 56.3% in the sarcopenic group and 10.4% in the nonsarcopenic group (P < 0.001). CONCLUSIONS: PLR might help identifying a subgroup of CTLI patients associated with poor prognosis but does not seem appropriate to be used as a marker of sarcopenia given its low sensitivity.


Asunto(s)
Plaquetas , Isquemia/cirugía , Linfocitos , Enfermedad Arterial Periférica/cirugía , Sarcopenia/diagnóstico , Procedimientos Quirúrgicos Vasculares , Anciano , Anciano de 80 o más Años , Enfermedad Crítica , Femenino , Humanos , Isquemia/sangre , Isquemia/diagnóstico , Isquemia/mortalidad , Recuento de Linfocitos , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/sangre , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/mortalidad , Recuento de Plaquetas , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Sarcopenia/sangre , Sarcopenia/mortalidad , Factores de Tiempo , Procedimientos Quirúrgicos Vasculares/efectos adversos , Procedimientos Quirúrgicos Vasculares/mortalidad
9.
Ann Vasc Surg ; 74: 526.e7-526.e12, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33836224

RESUMEN

CASE REPORT: Classical surgical options for renal artery aneurysm (RAA) are usually restricted to endovascular surgery or open repair, either using an in-situ or ex-situ approach. A 45-year-old woman presenting with a 20-mm complex RAA with hilum location, not suitable for endovascular repair renal was treated with a mini-invasive robotic approach. This approach allowed an in-situ reconstruction in a complete mini-invasive manner with the Da Vinci Xi robot (Intuitive Surgical, Sunnyvale, CA). The robotic system was used for both surgical exposure and aneurysmectomy with patch closure. Clamping time was 38 minutes (warm ischemia), total operative time was 210 minutes. LIITERATURE REVIEW: A comprehensive literature review was performed concerning the studies reporting a robotic approach for RAA. Main outcomes of interest were surgical technique, total operative time, clamping time, blood loss and postoperative renal function. Seven studies were identified, reporting a total of 20 RAAs. Most of the RAA were treated by aneurysmoraphy (n=9). Median total operative time varied between 228 and 300 min (range: 155 - 360 minutes), median clamping time varied between 26 and 44 minutes (range: 10 - 82 minutes). Median blood loss was comprised between100 and 150 mL (range: 25 - 650 mL). No alteration of renal function in the early post-operative period was reported. CONCLUSION: RAA in-situ repair with a robotic approach is feasible and safe and should be considered as an alternative to open surgical repair when endovascular technique cannot be an option.


Asunto(s)
Aneurisma/cirugía , Arteria Renal/cirugía , Procedimientos Quirúrgicos Robotizados , Procedimientos Quirúrgicos Vasculares , Aneurisma/diagnóstico por imagen , Femenino , Humanos , Persona de Mediana Edad , Arteria Renal/diagnóstico por imagen , Resultado del Tratamiento
10.
Eur J Vasc Endovasc Surg ; 60(5): 773-779, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-32792290

RESUMEN

OBJECTIVE: Compliance is considered to be a major property influencing the long term performances of synthetic vascular substitutes that could play a role in anastomotic false aneurysm and intimal hyperplasia stenosis onset. Over the last decades, manufacturers have tried to develop substitutes that mechanically mimic arterial properties and avoid a compliance mismatch at the anastomoses in particular. However, data are missing about how initial compliance properties could change with time. The goal of this study was to evaluate how the compliance of vascular grafts evolves under cyclic loading conditions in vitro. METHODS: The compliance of three different models of commercially available textile polyethylene terephthalate (PET) grafts was evaluated. Tests were performed with and without their original coating. Compliance was assessed with a specific device dedicated to measure the deformations undergone by a graft under cyclic pressure loading conditions, using image analysis software. In each experiment, image analysis was performed under 60 and 140 mmHg pressure loading conditions at loading start (H0) and after three, six, and 24 h (H3, H6, H24) loading time. Average radial, longitudinal, and volumetric compliance was calculated from the obtained images. RESULTS: Twenty-four samples were tested. Results demonstrate that all values decreased significantly within only a few hours. On average, the loss of compliance after 3 h of cyclic loading ranged on average from 35% for longitudinal compliance to 39% for radial compliance and 37% (p < .050) for volume compliance. After 24 h, the loss of radial, longitudinal and volume compliance was respectively 63 ± 3%, 60.5 ± 2% and 61 ± 7%. CONCLUSION: In this in vitro model, PET graft compliance has already decreased significantly within 3 h. The rapid loss of compliance identified in this experimental study helps explain the mismatch mentioned in clinical observations.


Asunto(s)
Prótesis Vascular , Ensayo de Materiales/estadística & datos numéricos , Tereftalatos Polietilenos , Textiles , Injerto Vascular/instrumentación , Adaptabilidad , Estrés Mecánico , Factores de Tiempo
11.
Eur J Vasc Endovasc Surg ; 59(1): 51-58, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31732469

RESUMEN

OBJECTIVE: The aim of this study was to assess the post-operative volumetric evolution of common iliac arteries (CIA) ≥ 17 mm diameter with respect to the type of endovascular technique performed and to assess type 1b endoleak risk factors. METHODS: All consecutive patients presenting with aneurysmal disease with CIA ≥17 mm treated endovascularly from 2008 to 2016 were included. Patients were divided into two groups dependent upon the type of endovascular technique performed: bell bottom technique (BBT group), vs. other techniques (non-BBT group). Volumetric evolution of the CIA was assessed for each patient by computed tomography angiographic reconstructions performed pre-operatively, at six months, one year, and two years. Multivariable analysis was performed to identify risk factors for type 1b endoleak. RESULTS: From 2008 to 2016, 74 patients with 110 CIA ≥17 mm were treated (BBT group: n = 58; non-BBT group: n = 52). Mean follow up was 48.1 months (median 39.0, IQR 38.1). Mean volumetric evolution significantly differed in the BBT group +14.2% (median 19.9%, IQR 24.6) compared with the non-BBT group: -20.9% (median -20.1%, IQR -26.0), p < .001. The five year type 1b endoleak related re-intervention rate was 16.1% and 7.7% in the BBT and non-BBT groups, respectively (p = .04), mean time to type 1b endoleak was 24.8 months and 54.3 months, respectively. The BBT appeared as a risk factor for type 1b endoleak (OR: 7.13; 95% CI: 1.58-3.04; p < .001). CONCLUSION: The BBT is associated with an increase in CIA volume post-operatively and consequently can be considered a risk factor for type 1b endoleak. It might be avoided if an iliac branched endograft is possible.


Asunto(s)
Implantación de Prótesis Vascular/efectos adversos , Endofuga/epidemiología , Procedimientos Endovasculares/efectos adversos , Aneurisma Ilíaco/cirugía , Arteria Ilíaca/cirugía , Anciano , Anciano de 80 o más Años , Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/métodos , Angiografía por Tomografía Computarizada , Endofuga/diagnóstico por imagen , Endofuga/etiología , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/métodos , Femenino , Estudios de Seguimiento , Humanos , Aneurisma Ilíaco/diagnóstico por imagen , Aneurisma Ilíaco/mortalidad , Arteria Ilíaca/diagnóstico por imagen , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Factores de Riesgo , Stents/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
12.
Ann Vasc Surg ; 64: 2-10, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31629851

RESUMEN

BACKGROUND: Common femoral artery (CFA) stenting appears as a promising alternative treatment to the open surgery for de novo CFA stenosis. The stenting of lesions just located at the CFA is simple, whereas stenting of CFA bifurcation lesions is more complex, and outcomes are still matter of debate. The aim of this study was to describe and to compare clinical outcomes of techniques used to treat simple over complex lesions for the stenting of CFA lesions. MATERIALS/METHODS: From the French randomized controlled trial, TECCO, a total of 54 patients underwent stenting intervention and were enrolled in this study. Patients were excluded if they had CFA thrombosis, restenosis, and nonatheromatous lesions. Patients were classified by simple and complex lesions based on the type of lesion. The primary end point was the primary sustained clinical improvement. RESULTS: Eighteen patients were included in the simple lesion group, and 36 patients, in the complex lesion group. Baseline characteristics of patients were comparable between the 2 groups. The technical success was 100% in the simple lesion group and 91.7% in the complex lesion group. There was no significant difference between the 2 groups, regarding the primary sustained clinical improvement. The primary patency rates at 24 months for simple and complex lesion groups were 86.3% and 79%, respectively (P = 0.66). Freedom from target lesion revascularization was of 93.3% and 82% in the simple and complex lesion group, respectively (P = 0.34). CONCLUSIONS: The stenting technique for CFA bifurcation lesions is a safe and effective technique. More trials with a large number of patients are needed to define the optimal stenting technique.


Asunto(s)
Procedimientos Endovasculares/instrumentación , Arteria Femoral , Enfermedad Arterial Periférica/terapia , Stents , Anciano , Constricción Patológica , Procedimientos Endovasculares/efectos adversos , Femenino , Arteria Femoral/diagnóstico por imagen , Arteria Femoral/fisiopatología , Francia , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/fisiopatología , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
13.
J Vasc Surg ; 70(5): 1399-1408.e1, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31126765

RESUMEN

OBJECTIVE: The Valiant Navion stent graft system (Medtronic, Santa Rosa, Calif) is a new iteration of a thoracic endograft for the treatment of descending thoracic aortic aneurysms. Herein, the 30-day primary safety and efficacy outcomes and secondary end points are presented. METHODS: The Valiant EVO global clinical trial is a prospective, nonrandomized, single-arm trial. Patient enrollment occurred from April 2016 to October 2017. The primary end point was defined as access and/or deployment failure and/or a major device effect (MDE), including device-related secondary procedures, device-related mortality, conversion to open surgery, or thoracic aortic aneurysm rupture within 30 days of the index procedure. Other measures of stent graft performance including procedural data, rates of secondary procedures, and frequency of endoleaks are also reported. RESULTS: Of the 87 consecutive patients undergoing thoracic endovascular aneurysm repair who were enrolled, 33 (37.9%) were female with 61 (70.9%) presenting with severe access artery tortuosity and 66 (85.7%) with high thoracic aortic tortuosity per core laboratory evaluation. The mean procedure duration was 88.7 ± 53.4 minutes and geographical differences existed such as percutaneous access (37/52 [71.2%]) in the United States and surgical cut down in the outside of the U.S. sites (28/35 [80.0%]). There were no access or deployment failures and only 2.3% of the patients (2/87; P < .0001; performance goal of 16%) experienced a MDE within 30 days of the index procedure. Two secondary procedures (n = 1 retrograde type A dissection; n = 1 aortic arch rupture) were required, and in the first 30 days, two patients died leading to a freedom from all-cause mortality of 97.7%. Endoleaks at 1 month were reported in 2.5% of patients (n = 1 type Ia; n = 1 type II). CONCLUSIONS: Access/deployment failures, MDEs, and endoleaks were rare in the first 30 days of the Valiant Evo clinical trial. The Valiant Navion thoracic stent graft system has shown encouraging 30-day results in this challenging cohort and trial patients will continue to be followed through 5 years.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Endofuga/epidemiología , Procedimientos Endovasculares/efectos adversos , Stents/efectos adversos , Anciano , Aneurisma de la Aorta Torácica/mortalidad , Implantación de Prótesis Vascular/instrumentación , Conversión a Cirugía Abierta/estadística & datos numéricos , Endofuga/etiología , Procedimientos Endovasculares/instrumentación , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Falla de Prótesis , Reoperación/estadística & datos numéricos , Resultado del Tratamiento
14.
Eur J Vasc Endovasc Surg ; 58(4): 576-582, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31422047

RESUMEN

OBJECTIVES: The current study was performed in order to determine the influence of hypercholesterolaemia on critical limb ischaemia (CLI) and whether targeting oxidative stress by antioxidant therapies such as N-acetyl cysteine (NAC), considered to be a direct scavenger of reactive oxygen species, could confer muscle protection. METHODS: Apolipoprotein E (ApoE)-/- mice (n = 9, 29 weeks old) and their genetic controls ApoE+/+ mice (n = 9, 29 weeks old) were submitted to sequential right femoral and iliac ligations; the left limb served as control. ApoE+/+ mice were divided into two groups: Group 1 (n = 4) and Group 2 (n = 5); as well as ApoE-/- mice: Group 3 (n = 3), and Group 4 (n = 6). NAC treatment was administered to Groups 2 and 4 in drinking water. Mice were sacrificed on Day 40 and gastrocnemius muscles were harvested to study mitochondrial respiration by oxygraphy, calcium retention capacity by spectrofluorometry, and production of reactive oxygen species by electron paramagnetic resonance. RESULTS: CLI associated with ApoE deficiency resulted in more severe mitochondrial dysfunction: maximum oxidative capacity and calcium retention capacity were decreased (-42.9% vs. -25.1%, p = .010; and -73.1% vs. -40.3%, p = .003 respectively) and production of reactive oxygen species was enhanced (+63.6% vs. +41.4%, p = .03) in ApoE-/- mice compared with ApoE+/+ mice respectively. Antioxidant treatment restored oxidative capacity, calcium retention capacity and decreased production of reactive oxygen species in both mice strands. CONCLUSIONS: In this small murine study, hypercholesterolaemia exacerbated mitochondrial dysfunction, as clinically expected; but antioxidant therapy appeared protective, which is counter to clinical experience. Further work is clearly needed.


Asunto(s)
Acetilcisteína/farmacología , Antioxidantes/farmacología , Hiperlipidemias/complicaciones , Isquemia/tratamiento farmacológico , Mitocondrias Musculares/efectos de los fármacos , Músculo Esquelético/efectos de los fármacos , Estrés Oxidativo/efectos de los fármacos , Enfermedad Arterial Periférica/tratamiento farmacológico , Animales , Calcio/metabolismo , Enfermedad Crítica , Modelos Animales de Enfermedad , Hiperlipidemias/genética , Hiperlipidemias/metabolismo , Isquemia/etiología , Isquemia/metabolismo , Isquemia/patología , Ratones Noqueados para ApoE , Mitocondrias Musculares/metabolismo , Mitocondrias Musculares/patología , Músculo Esquelético/metabolismo , Músculo Esquelético/patología , Enfermedad Arterial Periférica/etiología , Enfermedad Arterial Periférica/metabolismo , Enfermedad Arterial Periférica/patología , Especies Reactivas de Oxígeno/metabolismo
15.
Ann Vasc Surg ; 60: 479.e11-479.e15, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31200062

RESUMEN

We report the case of a 68-year-old man complaining of sudden intermittent claudication of the left limb. The patient was rapidly diagnosed with duplex ultrasound (DUS), computed tomography angiography, and magnetic resonance angiography as having a popliteal cyst (PC) compressing the popliteal artery, responsible for intermittent claudication. The patient underwent DUS-guided PC aspiration allowing symptoms resolution. However, he presented 3 recurrent ischemic syndromes from brutal claudication to more severe ischemia in a 3-month period, with increasing severity of the symptoms, treated with 3 DUS-guided PC aspirations. An extensive work-up excluded an atherosclerotic etiology. Consequently, due to increasing severity and quick recurrence of the symptoms and given the underlying knee osteoarthritis, the patient underwent radical treatment and got a total knee prosthetic replacement. One year later, follow-up was uneventful.


Asunto(s)
Arteriopatías Oclusivas/etiología , Claudicación Intermitente/etiología , Isquemia/etiología , Osteoartritis de la Rodilla/complicaciones , Arteria Poplítea , Quiste Poplíteo/complicaciones , Enfermedad Aguda , Anciano , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/fisiopatología , Artroplastia de Reemplazo de Rodilla , Humanos , Claudicación Intermitente/diagnóstico por imagen , Claudicación Intermitente/fisiopatología , Isquemia/diagnóstico por imagen , Isquemia/fisiopatología , Masculino , Osteoartritis de la Rodilla/diagnóstico por imagen , Osteoartritis de la Rodilla/cirugía , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Quiste Poplíteo/diagnóstico por imagen , Quiste Poplíteo/terapia , Recurrencia , Flujo Sanguíneo Regional , Resultado del Tratamiento
16.
Eur J Vasc Endovasc Surg ; 56(5): 730-738, 2018 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30172667

RESUMEN

OBJECTIVE/BACKGROUND: The aim of this study was to investigate whether antioxidant therapy might decrease oxidative stress related deleterious effects in the setting of critical limb ischaemia (CLI). METHODS: Twenty Swiss mice were submitted to sequential right femoral and iliac ligatures; the left limb served as control. The mice were assigned to two groups: in the first group (no-treatment group, n = 10) no treatment was administered; in the second group (N-acetyl cysteine [NAC] group, n = 10) NAC was administered by dissolution in drinking water for 4 weeks, starting on day 7, when CLI was effective. Clinical and functional scores were assessed by two blinded investigators. Mice were killed on day 40 and mitochondrial respiratory chain complex activities, calcium retention capacity, oxidative stress, and histological analysis were analysed. RESULTS: Ischaemic muscles in the no-treatment group showed significantly impaired mitochondrial respiration and calcium retention capacity, with increased production of reactive oxygen species; but no statistical difference was noticed when comparing ischaemic muscles in the NAC group (n = 10) to contralateral muscles (n = 10) and to control muscles in the no-treatment group (n = 10). Ischaemic muscles in the no-treatment group exhibited myopathic features such as wider range in fibre size, rounded shape, centrally located nuclei, and smaller cross sectional areas, but none of these features were observed in contralateral muscles or in NAC-group muscles (ischaemic or controls). CONCLUSION: Targeting inhibition of oxidative stress may be a potential therapeutic strategy for muscle protection in CLI and might be considered as potential adjunctive therapy to revascularisation procedures.


Asunto(s)
Acetilcisteína/uso terapéutico , Isquemia/tratamiento farmacológico , Mitocondrias/efectos de los fármacos , Estrés Oxidativo/efectos de los fármacos , Animales , Calcio/metabolismo , Isquemia/metabolismo , Masculino , Ratones , Músculo Esquelético/irrigación sanguínea , Especies Reactivas de Oxígeno/metabolismo
17.
Eur J Vasc Endovasc Surg ; 55(4): 567-576, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29478909

RESUMEN

OBJECTIVE/BACKGROUND: Since the late 1950s, major advances in vascular surgical practice have been closely associated with the introduction of novel vascular implants. These devices have been constructed from a variety of materials and have been designed to be implanted in several different ways. Despite a rigorous regulatory process, regular failures continue to be observed. A systematic review of the literature and of the Geprovas registry was performed in order to improve understanding of the failures. METHODS: A systematic review was performed via a search of the MEDLINE and Embase databases. Full text, English, German, or French language studies without any chronological limit were included. The reference lists of included studies, as well as the first 20 related items, were scanned for other potentially relevant studies. RESULTS: Data extraction allowed the evaluation of 184 publications; 72 publications met the inclusion criteria. Only 12 publications reported sufficient data for structural, histopathological, and epidemiological analysis. However, explant analysis allowed the understanding of degenerative phenomena: "warp knitted" replaced "weft knitted" polyethylene terephthalate grafts, decreasing the risk of dilatation or rupture; inter-nodal distance was modified in order to improve polytetrafluoroethylene graft incorporation capacities; and index of saturation, endograft fabric/stent interactions, and stent fatigue phenomena have been extensively studied in an attempt to improve endovascular device durability. CONCLUSION: A general lack of depth of reporting of explants remains. Dedicated systematic explant analysis programs are the key to improving the performance of future generations of devices.


Asunto(s)
Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Remoción de Dispositivos/métodos , Procedimientos Endovasculares/instrumentación , Stents , Implantación de Prótesis Vascular/efectos adversos , Remoción de Dispositivos/efectos adversos , Procedimientos Endovasculares/efectos adversos , Análisis de Falla de Equipo , Humanos , Diseño de Prótesis , Falla de Prótesis , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
18.
Ann Vasc Surg ; 51: 150-159, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29481923

RESUMEN

BACKGROUND: The goal of the present study was to identify the potential degradations undergone by textile endoprostheses (EPs) over the crimping process related to the catheter insertion purpose. In particular, we studied how the device design parameters can influence the wrinkling of the textile material, assuming that wrinkling induces stress concentration and may jeopardize the lifetime of the device. MATERIALS AND METHODS: Custom-designed EPs were obtained from various stent designs and textile constructions. Monofilament and multifilament materials were considered for the cover. Stent segment size, distance, and wire diameter were considered as variable for the stent. The EPs of 26-mm diameter were then crimped in a mock transparent 6-mm diameter catheter sheath for 8 and 30 days duration. After releasing the EPs from the sheath, the textile cover was characterized for roughness properties to identify the crease level induced on the surface by crimping. RESULTS: Results brought out that the monofilament material was characterized by a larger number of deeper creases in the zones where the stent was in contact with the cover. Conversely, the multifilament was more folded in the zones between stent segments. Moreover, it appeared that the stent design influenced the creases' topography. The textile seemed to be less prone to heavy wrinkling with stent segments made from larger wire diameter and larger segment size. Regarding the crimping duration, it came out that a longer stay in the sheath tends to promote more significant wrinkling. CONCLUSIONS: In this work, it was shown that wrinkling of the textile cover occurs in the EPs already at crimping level. However, an appropriate design of the EPs should limit the phenomenon and improve the performances of the EPs.


Asunto(s)
Aorta/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/efectos adversos , Humanos , Ensayo de Materiales , Diseño de Prótesis , Falla de Prótesis , Estrés Mecánico , Propiedades de Superficie , Textiles
19.
Ann Vasc Surg ; 47: 283.e1-283.e4, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-28947218

RESUMEN

We report the case of a 71-year-old man complaining of swollen left limb and progressively worsening pain. He underwent surgery 12 years ago for popliteal artery aneurysm with proximal and distal ligation and venous bypass grafting. The patient was diagnosed as having left peroneal neuropathy caused by a 10.5 cm expanded aneurysmal sac compressing the peroneal nerve in the popliteal fossa. The patient underwent open repair with opening of the aneurysmal sac, removal of the thrombus, and sewing of the left genicular artery responsible for back-bleeding. Postoperative range of motion exercises and physical therapy allowed resolving foot drop 1 year after surgery.


Asunto(s)
Aneurisma/cirugía , Síndromes de Compresión Nerviosa/etiología , Neuropatías Peroneas/etiología , Arteria Poplítea/cirugía , Injerto Vascular/efectos adversos , Anciano , Aneurisma/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Terapia por Ejercicio , Humanos , Ligadura , Masculino , Síndromes de Compresión Nerviosa/diagnóstico , Síndromes de Compresión Nerviosa/fisiopatología , Síndromes de Compresión Nerviosa/rehabilitación , Neuropatías Peroneas/diagnóstico , Neuropatías Peroneas/fisiopatología , Neuropatías Peroneas/rehabilitación , Arteria Poplítea/diagnóstico por imagen , Reoperación , Factores de Tiempo , Resultado del Tratamiento
20.
Ann Vasc Surg ; 50: 119-127, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29501897

RESUMEN

BACKGROUND: The purpose of this study was to report midterm outcomes of open repair (OR) or endovascular repair (ER) of popliteal artery aneurysms (PAAs) and assess if outcomes of patients have changed in the endovascular era. METHODS: This monocentric and retrospective study included all consecutive patients treated for PAA between January 2004 and December 2016. Before 2010, all patients underwent OR, but ER was available since 2010, and the choice between OR or ER was made on the basis of clinical presentation and preoperative morphological assessment. Survival, primary patency, primary-assisted patency, secondary patency, and limb salvage rates were assessed regarding the surgical way of treatment (OR or ER) or regarding the period of time (before 2010 or since 2010). RESULTS: A total of 153 PAA were treated in 126 patients (103 limbs in OR and 50 limbs in ER). Mean follow-up was 3.8 years. Five-year survival was 97.7% for OR and 88.7% for ER. Five-year primary patency was 77.8% and 29.5% for OR and ER, respectively, primary-assisted patency 85.0% and 49.7%, respectively, and secondary patency 92.8% and 79.6%, respectively. Five-year limb salvage was 89.5% for OR and 87.9% for ER. No outcome difference was observed between patients who underwent surgery before or after ER was available. CONCLUSIONS: Results of OR and ER in the setting of PAA are satisfactory. Outcomes of patients did not change in the endovascular era.


Asunto(s)
Aneurisma/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Arteria Poplítea/cirugía , Anciano , Anciano de 80 o más Años , Aneurisma/diagnóstico por imagen , Aneurisma/mortalidad , Aneurisma/fisiopatología , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Recuperación del Miembro , Masculino , Persona de Mediana Edad , Arteria Poplítea/diagnóstico por imagen , Arteria Poplítea/fisiopatología , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Grado de Desobstrucción Vascular
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA