Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 107
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Cytotherapy ; 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38819362

RESUMEN

Chimeric antigen receptor cell therapy is a successful immunotherapy for the treatment of blood cancers. However, hurdles in their manufacturing remain including efficient isolation and purification of the T-cell starting material. Herein, we describe a one-step separation based on inertial spiral microfluidics for efficient enrichment of T-cells in B-cell acute lymphoblastic leukemia (ALL) and B-cell chronic lymphocytic leukemia patient's samples. In healthy donors used to optimize the process, the lymphocyte purity was enriched from 65% (SD ± 0.2) to 91% (SD ± 0.06) and T-cell purity was enriched from 45% (SD ± 0.1) to 73% (SD ± 0.02). Leukemic samples had higher starting B-cells compared to the healthy donor samples. Efficient enrichment and recovery of lymphocytes and T-cells were achieved in ALL samples with B-cells, monocytes and leukemic blasts depleted by 80% (SD ± 0.09), 89% (SD ± 0.1) and 74% (SD ± 0.09), respectively, and a 70% (SD ± 0.1) T-cell recovery. Chronic lymphocytic leukemia samples had lower T-cell numbers, and the separation process was less efficient compared to the ALL. This study demonstrates the use of inertial microfluidics for T-cell enrichment and depletion of B-cell blasts in ALL, suggesting its potential to address a key bottleneck of the chimeric antigen receptor-T manufacturing workflow.

2.
Small ; 19(21): e2204956, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36840671

RESUMEN

Accurate delineation of gross tumor volumes remains a barrier to radiotherapy dose escalation and boost dosing in the treatment of solid tumors, such as prostate cancer. Magnetic resonance imaging (MRI) of tumor targets has the power to enable focal dose boosting, particularly when combined with technological advances such as MRI-linear accelerator. Fibroblast activation protein (FAP) is overexpressed in stromal components of >90% of epithelial carcinomas. Herein, the authors compare targeted MRI of prostate specific membrane antigen (PSMA) with FAP in the delineation of orthotopic prostate tumors. Control, FAP, and PSMA-targeting iron oxide nanoparticles were prepared with modification of a lymphotropic MRI agent (FerroTrace, Ferronova). Mice with orthotopic LNCaP tumors underwent MRI 24 h after intravenous injection of nanoparticles. FAP and PSMA nanoparticles produced contrast enhancement on MRI when compared to control nanoparticles. FAP-targeted MRI increased the proportion of tumor contrast-enhancing black pixels by 13%, compared to PSMA. Analysis of changes in R2 values between healthy prostates and LNCaP tumors indicated an increase in contrast-enhancing pixels in the tumor border of 15% when targeting FAP, compared to PSMA. This study demonstrates the preclinical feasibility of PSMA and FAP-targeted MRI which can enable targeted image-guided focal therapy of localized prostate cancer.


Asunto(s)
Nanopartículas , Neoplasias de la Próstata , Masculino , Humanos , Animales , Ratones , Próstata , Imagen por Resonancia Magnética , Fibroblastos
3.
Surg Endosc ; 37(8): 6185-6196, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37165173

RESUMEN

BACKGROUND: Gastrectomy with extended (D2) lymphadenectomy is considered standard of care for gastric cancer to provide the best possible outcomes and pathologic staging. However, D2 gastrectomy is a technically demanding operation and reported to be associated with increased complications and mortality. Application of sentinel lymph node (SLN) concept in gastric cancer has the potential to reduce patient morbidity; however, SLN techniques are not established for gastrectomy, in part due to lack of practical tracers. An effective and convenient tracer with enhanced SLN accumulation is critically needed. METHODS: Mannose-labelled magnetic tracer 'FerroTrace' and fluorescent dye indocyanine green (ICG) were injected laparoscopically into the stomach submucosa of 8 healthy swine under general anaesthesia. Intraoperative fluorescence imaging was used to highlight draining lymphatic pathways containing ICG, while preoperative T2-weighted MRI and ex vivo magnetometer probe measurements were used to identify nodes containing FerroTrace. Lymphadenectomy was performed either robotically (n = 2) or via laparotomy (n = 6). RESULTS: Mixing ICG and FerroTrace ensured concurrence of fluorescent and magnetic signals in SLNs. An initial trial with robotic dissection removed all magnetic LNs (n = 4). In the subsequent laparotomy study that targeted all ICG-LNs based on intraoperative fluorescence imaging, dissection removed an average of 4.7 ± 1.2 fluorescent, and 2.0 ± 1.3 magnetic LNs per animal. Both MRI and magnetometer detected 100% of SLNs (n = 7). FerroTrace demonstrated high specificity to SLNs, which contained 76 ± 30% of total lymphotropic iron, and 88 ± 20 % of the overall magnetometer signal. CONCLUSIONS: Through utilisation of this dual tracer approach, SLNs were identified via preoperative MRI, visualised intraoperatively with fluorescence imaging, and confirmed with a magnetometer. This combination pairs the sensitivity of ICG with SLN-specific FerroTrace and can be used for reliable SLN detection in gastric cancer, with potential applications in neoadjuvant therapy.


Asunto(s)
Nanopartículas de Magnetita , Ganglio Linfático Centinela , Neoplasias Gástricas , Animales , Porcinos , Ganglio Linfático Centinela/diagnóstico por imagen , Ganglio Linfático Centinela/cirugía , Ganglio Linfático Centinela/patología , Verde de Indocianina , Biopsia del Ganglio Linfático Centinela/métodos , Manosa , Neoplasias Gástricas/diagnóstico por imagen , Neoplasias Gástricas/cirugía , Neoplasias Gástricas/patología , Colorantes , Escisión del Ganglio Linfático , Colorantes Fluorescentes , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/cirugía , Ganglios Linfáticos/patología
4.
J Nanobiotechnology ; 21(1): 102, 2023 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-36945003

RESUMEN

Disruption of the cell cycle is among the most effective approach to increase tumour cells' radio-sensitivity. However, the presence of dose-limiting side effects hampers the clinical use of tyrosine kinase inhibitors targeting the cell cycle. Towards addressing this challenge, we identified a bosutinib nanoformulation within high density lipoprotein nanoparticles (HDL NPs) as a promising radiosensitiser. Bosutinib is a kinase inhibitor clinically approved for the treatment of chronic myeloid leukemia that possesses radiosensitising properties through cell cycle checkpoint inhibition. We found that a remarkably high bosutinib loading (> 10%) within HDL NPs could be reliably achieved under optimal preparation conditions. The radiosensitisation activity of the bosutinib-HDL nanoformulation was first assessed in vitro in UM-SCC-1 head and neck squamous cell carcinoma (HNSCC) cells, which confirmed efficient disruption of the radiation induced G2/M cell cycle arrest. Interestingly, the bosutinib nanoformulation out-performed free bosutinib, likely because of the specific affinity of HDL NPs with tumour cells. The combination of bosutinib-HDL NPs and radiotherapy significantly controlled tumour growth in an immunocompetent murine HNSCC model. The bosutinib-HDL nanoformulation also enhanced the radiation induced immune response through the polarisation of tumour associated macrophages towards proinflammatory phenotypes.


Asunto(s)
Antineoplásicos , Neoplasias de Cabeza y Cuello , Animales , Ratones , Carcinoma de Células Escamosas de Cabeza y Cuello/tratamiento farmacológico , Carcinoma de Células Escamosas de Cabeza y Cuello/radioterapia , Antineoplásicos/farmacología , Compuestos de Anilina/farmacología , Inhibidores de Proteínas Quinasas/farmacología , Inhibidores de Proteínas Quinasas/uso terapéutico , Neoplasias de Cabeza y Cuello/tratamiento farmacológico , Neoplasias de Cabeza y Cuello/radioterapia
5.
Parasitol Res ; 122(12): 2891-2905, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37776335

RESUMEN

Cryptosporidium is a major cause of diarrhoeal disease and mortality in young children in resource-poor countries, for which no vaccines or adequate therapeutic options are available. Infection in humans is primarily caused by two species: C. hominis and C. parvum. Despite C. hominis being the dominant species infecting humans in most countries, very little is known about its growth characteristics and life cycle in vitro, given that the majority of our knowledge of the in vitro development of Cryptosporidium has been based on C. parvum. In the present study, the growth and development of two C. parvum isolates (subtypes Iowa-IIaA17G2R1 and IIaA18G3R1) and one C. hominis isolate (subtype IdA15G1) in HCT-8 cells were examined and compared at 24 h and 48 h using morphological data acquired with scanning electron microscopy. Our data indicated no significant differences in the proportion of meronts or merozoites between species or subtypes at either time-point. Sexual development was observed at the 48-h time-point across both species through observations of both microgamonts and macrogamonts, with a higher frequency of macrogamont observations in C. hominis (IdA15G1) cultures at 48-h post-infection compared to both C. parvum subtypes. This corresponded to differences in the proportion of trophozoites observed at the same time point. No differences in proportion of microgamonts were observed between the three subtypes, which were rarely observed across all cultures. In summary, our data indicate that asexual development of C. hominis is similar to that of C. parvum, while sexual development is accelerated in C. hominis. This study provides new insights into differences in the in vitro growth characteristics of C. hominis when compared to C. parvum, which will facilitate our understanding of the sexual development of both species.


Asunto(s)
Criptosporidiosis , Cryptosporidium parvum , Cryptosporidium , Niño , Animales , Humanos , Preescolar , Iowa , Estadios del Ciclo de Vida
6.
Anal Chem ; 94(2): 1256-1263, 2022 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-34978430

RESUMEN

Continued advances in label-free electrical biosensors pave the way to simple, rapid, cost-effective, high-sensitivity, and quantitative biomarker testing at the point-of-care setting that would profoundly transform healthcare. However, implementation in routine diagnostics is faced with significant challenges associated with the inherent requirement for biofluid sample processing before and during testing. We present here a simple yet robust autonomous finger-prick blood sample processing platform integrated with nanoscale field-effect transistor biosensors and demonstrate the feasibility of measuring the SARS-CoV-2 nucleocapsid protein. The 3D-printed platform incorporates a high-yield blood-to-plasma separation module and a delay valve designed to terminate the assay at a specific time. The platform is driven by hydrostatic pressure to efficiently and automatically dispense plasma and washing/measurement buffer to the nanosensors. Our model study demonstrates the feasibility of detecting down to 1.4 pg/mL of the SARS-CoV-2 nucleocapsid protein within 25 min and with only minimal operator intervention.


Asunto(s)
COVID-19 , Sistemas de Atención de Punto , Biomarcadores , Humanos , Pruebas en el Punto de Atención , SARS-CoV-2
7.
Nanomedicine ; 42: 102546, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35278683

RESUMEN

Sentinel lymph node biopsy in cancers of the head and neck offers demonstrated clinical and diagnostic value, but adoption is limited by concerns about the detrimental consequence to survival of false negative results in a highly curable setting. The aim of this study was to demonstrate potential to overcome this via application of a novel mannose-labeled magnetic iron oxide tracer. In a large animal model, preoperative imaging and intraoperative magnetometer detection were used to identify magnetic lymph nodes. Iron quantification mapped the distribution of tracer within lymphatic levels. Over a 4-week test period, uptake of magnetic tracer in lymph nodes increased in a linear-like fashion, with a substantial percentage of accumulated iron (83%) being retained in the sentinel node. This result indicates a high affinity of mannose-labeled particles to the sentinel node, while providing a means for the magnetometer probe to indicate node status based on intraoperative signal.


Asunto(s)
Nanopartículas de Magnetita , Ganglio Linfático Centinela , Animales , Hierro , Ganglios Linfáticos , Fenómenos Magnéticos , Manosa , Ganglio Linfático Centinela/diagnóstico por imagen , Ganglio Linfático Centinela/cirugía , Biopsia del Ganglio Linfático Centinela/métodos
8.
Molecules ; 27(22)2022 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-36432052

RESUMEN

Metal-oxide semiconducting materials are promising for building high-performance field-effect transistor (FET) based biochemical sensors. The existence of well-established top-down scalable manufacturing processes enables the reliable production of cost-effective yet high-performance sensors, two key considerations toward the translation of such devices in real-life applications. Metal-oxide semiconductor FET biochemical sensors are especially well-suited to the development of Point-of-Care testing (PoCT) devices, as illustrated by the rapidly growing body of reports in the field. Yet, metal-oxide semiconductor FET sensors remain confined to date, mainly in academia. Toward accelerating the real-life translation of this exciting technology, we review the current literature and discuss the critical features underpinning the successful development of metal-oxide semiconductor FET-based PoCT devices that meet the stringent performance, manufacturing, and regulatory requirements of PoCT.


Asunto(s)
Técnicas Biosensibles , Transistores Electrónicos , Sistemas de Atención de Punto , Óxidos , Semiconductores
9.
Anal Chem ; 93(10): 4584-4592, 2021 03 16.
Artículo en Inglés | MEDLINE | ID: mdl-33656329

RESUMEN

Microfluidics-based technologies for single-cell analysis are becoming increasingly important tools in biological studies. With the increasing sophistication of microfluidics, cellular barcoding techniques, and next-generation sequencing, a more detailed picture of cellular subtype is emerging. Unfortunately, the majority of the methods developed for single-cell analysis are high-throughput and not suitable for rare cell analysis as they require a high input cell number. Here, we report a low-cost and reproducible method for rare single-cell analysis using a highly hydrophobic surface and nanosized static droplets. Our method allows rapid and efficient on-chip single-cell lysis and subsequent collection of genetic materials in nanoliter droplets using a micromanipulator or a laboratory pipette before subsequent genetic analysis. We show precise isolation of single cancer cells with high purity using two different strategies (i- cytospin and ii- static droplet array) for subsequent RNA analysis using droplet digital polymerase chain reaction (PCR) and real-time PCR. Our highly controlled isolation method opens a new avenue for the study of subcellular functional mechanisms, enabling the identification of rare cells of potential functional or pathogenic consequence.


Asunto(s)
Microfluídica , Análisis de la Célula Individual , Secuenciación de Nucleótidos de Alto Rendimiento , Reacción en Cadena de la Polimerasa
10.
Crit Rev Biotechnol ; 40(2): 213-230, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31906727

RESUMEN

Recently, organ-on-a-chip models, which are microfluidic devices that mimic the cellular architecture and physiological environment of an organ, have been developed and extensively investigated. The chips can be tailored to accommodate the disease conditions pertaining to many organs; and in the case of this review, the lung. Lung-on-a-chip models result in a more accurate reflection compared to conventional in vitro models. Pharmaceutical drug testing methods traditionally use animal models in order to evaluate pharmacological and toxicological responses to a new agent. However, these responses do not directly reflect human physiological responses. In this review, current and future applications of the lung-on-a-chip in the respiratory system will be discussed. Furthermore, the limitations of current conventional in vitro models used for respiratory disease modeling and drug development will be addressed. Highlights of additional translational aspects of the lung-on-a-chip will be discussed in order to demonstrate the importance of this subject for medical research.


Asunto(s)
Dispositivos Laboratorio en un Chip , Enfermedades Respiratorias/fisiopatología , Animales , Investigación Biomédica , Evaluación Preclínica de Medicamentos , Ensayos Analíticos de Alto Rendimiento , Humanos , Pulmón/efectos de los fármacos , Pulmón/fisiología , Modelos Biológicos , Fenómenos Farmacológicos y Toxicológicos , Impresión Tridimensional , Enfermedades Respiratorias/tratamiento farmacológico , Ingeniería de Tejidos
11.
Int J Mol Sci ; 21(2)2020 Jan 16.
Artículo en Inglés | MEDLINE | ID: mdl-31963205

RESUMEN

Metal nanoparticles are of increasing interest with respect to radiosensitization. The physical mechanisms of dose enhancement from X-rays interacting with nanoparticles has been well described theoretically, however have been insufficient in adequately explaining radiobiological response. Further confounding experimental observations is examples of radioprotection. Consequently, other mechanisms have gained increasing attention, especially via enhanced production of reactive oxygen species (ROS) leading to chemical-based mechanisms. Despite the large number of variables differing between published studies, a consensus identifies ROS-related mechanisms as being of significant importance. Understanding the structure-function relationship in enhancing ROS generation will guide optimization of metal nanoparticle radiosensitisers with respect to maximizing oxidative damage to cancer cells. This review highlights the physico-chemical mechanisms involved in enhancing ROS, commonly used assays and experimental considerations, variables involved in enhancing ROS generation and damage to cells and identifies current gaps in the literature that deserve attention. ROS generation and the radiobiological effects are shown to be highly complex with respect to nanoparticle physico-chemical properties and their fate within cells. There are a number of potential biological targets impacted by enhancing, or scavenging, ROS which add significant complexity to directly linking specific nanoparticle properties to a macroscale radiobiological result.


Asunto(s)
Nanopartículas del Metal/química , Protección Radiológica/métodos , Especies Reactivas de Oxígeno/metabolismo , Animales , Humanos , Modelos Teóricos , Oxidación-Reducción , Relación Estructura-Actividad
12.
Anal Chem ; 91(19): 12568-12573, 2019 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-31483135

RESUMEN

Potentiometric sensors based on silicon nanowire field effect transistors (SiNW FETs) typically display exquisite sensitivities, but their bioanalytical implementation is limited due to the need for stringent measurement conditions and high-precision readout units. An alternative operation principle where SiNW FETs are operated in a frequency-domain electrical impedimetric approach is promising. However, to date only limited data is available in regard to the sensing performance and translational relevance of this novel approach in comparison to the standard charge detection paradigm. We demonstrate the feasibility of conducting electrical impedimetric FET measurements with a portable unit for the ultrasensitive detection of cancer biomarkers in biospecimens. Compared to standard potentiometric measurements, electrical impedimetric FET measurements yielded significant improvements in biosensing performances, including the limit of detection, sensing resolution, and dynamic range.

13.
Anal Bioanal Chem ; 411(28): 7529-7538, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-31691854

RESUMEN

Quantification of intercellular heterogeneity in nanoparticle association is of paramount interest in research investigating applications of nanoparticles in the biomedical space. In this work, gold nanoparticle association (AuNP) in cell populations was quantified using synchrotron X-ray fluorescence microscopy (XRF) for 3 different cell lines (PC-3, Caco2 and MDA-MB-231) and 2 nanoparticle co-culture times (30 min and 10% of each respective cell lines' doubling time). Heterogeneity in association between single cells in the same population was dependant on cell line as well as co-culture time. AuNP association heterogeneity increased with co-culture time for 2 out of the 3 cell lines. Regardless of mean association quantity and measured intercellular heterogeneity, all data were best described by log normal distributions. Mean association between cell lines was statistically different at 30 min, yet indistinguishable at 10% doubling time. Heterogeneity between cell lines which demonstrated statistical differences in distribution can exist despite having statistically indistinguishable means.


Asunto(s)
Oro/metabolismo , Nanopartículas del Metal/química , Línea Celular , Técnicas de Cocultivo , Oro/química , Humanos , Microscopía Fluorescente , Sincrotrones
14.
Sensors (Basel) ; 19(2)2019 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-30650578

RESUMEN

Surface plasmon enhanced light scattering (SP-LS) is a powerful new sensing SPR modality that yields excellent sensitivity in sandwich immunoassay using spherical gold nanoparticle (AuNP) tags. Towards further improving the performance of SP-LS, we systematically investigated the AuNP size effect. Simulation results indicated an AuNP size-dependent scattered power, and predicted the optimized AuNPs sizes (i.e., 100 and 130 nm) that afford extremely high signal enhancement in SP-LS. The maximum scattered power from a 130 nm AuNP is about 1700-fold higher than that obtained from a 17 nm AuNP. Experimentally, a bio-conjugation protocol was developed by coating the AuNPs with mixture of low and high molecular weight PEG molecules. Optimal IgG antibody bioconjugation conditions were identified using physicochemical characterization and a model dot-blot assay. Aggregation prevented the use of the larger AuNPs in SP-LS experiments. As predicted by simulation, AuNPs with diameters of 50 and 64 nm yielded significantly higher SP-LS signal enhancement in comparison to the smaller particles. Finally, we demonstrated the feasibility of a two-step SP-LS protocol based on a gold enhancement step, aimed at enlarging 36 nm AuNPs tags. This study provides a blue-print for the further development of SP-LS biosensing and its translation in the bioanalytical field.


Asunto(s)
Técnicas Biosensibles , Inmunoensayo/métodos , Nanopartículas del Metal/química , Dispersión Dinámica de Luz , Oro/química , Humanos , Inmunoconjugados/química , Inmunoconjugados/inmunología , Inmunoglobulina G/química , Inmunoglobulina G/inmunología , Resonancia por Plasmón de Superficie
15.
J Mater Sci Mater Med ; 29(6): 76, 2018 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-29845339

RESUMEN

Accuracy of sentinel lymph node identification using radioactive tracers in non-superficial cancers can be limited by radiation shine through and low spatial resolution of detection systems such as intraoperative gamma probes. By utilising a dual radioactive/magnetic tracer, sensitive lymphoscintigraphy can be paired with high spatial resolution intraoperative magnetometer probes to improve the accuracy of sentinel node detection in cancers with complex multidirectional lymphatic drainage. Dextran-coated magnetite nanoparticles (33 nm mean hydrodynamic diameter) were labelled with 99mTc and applied as a lymphotropic tracer in small and large animal models. The dual tracer could be radiolabelled with 98 ± 2% efficiency after 10 min of incubation at room temperature. Biodistribution studies of the tracer were conducted in normal rats (subdermal and intravenous tail delivery, n = 3) and swine (subdermal hind limb delivery, n = 5). In rats the dual tracer migrated through four tiers of lymph node, 20 min after subdermal injection. Results from intravenous biodistribution test for radiocolloids demonstrated no aggregation in vivo, however indicated the presence of some lower-molecular weight radioactive impurities (99mTc-dextran). In swine, the dual tracer could be effectively used to map lymphatic drainage from hind hoof to popliteal and inguinal basins using intraoperative gamma and magnetometer probes. Of the eight primary nodes excised, eight were positively identified by gamma probe and seven by magnetometer probe. The high-purity dual tracer shows early promise for sentinel node identification in complex lymphatic environments by combining sensitive preoperative lymphoscintigraphy with a high-resolution intraoperative magnetometer probe.


Asunto(s)
Nanopartículas de Magnetita/química , Ganglio Linfático Centinela/patología , Tecnecio/química , Animales , Coloides/química , Dextranos/química , Femenino , Óxido Ferrosoférrico , Linfocintigrafia , Imagen por Resonancia Magnética , Microscopía Electrónica de Transmisión , Neoplasias/diagnóstico por imagen , Cintigrafía , Ratas , Ratas Sprague-Dawley , Porcinos , Temperatura , Distribución Tisular
16.
Anal Chem ; 88(23): 11924-11930, 2016 12 06.
Artículo en Inglés | MEDLINE | ID: mdl-27934101

RESUMEN

Development of new detection methodologies and amplification schemes is indispensable for plasmonic biosensors to improve the sensitivity for the detection of trace amounts of analytes. Herein, an ultrasensitive scheme for signal enhancement based on the concept of surface-plasmon-resonance-enhanced light scattering (SP-LS) was validated experimentally and theoretically. The SP-LS of gold nanoparticles' (AuNPs) tags was employed in a sandwich assay for the detection of cardiac troponin I and provided up to 2 orders of magnitude improved sensitivity over conventional AuNPs-enhanced refractometric measurements and 3 orders of magnitude improvement over label-free SPR. Simulations were also performed to provide insights into the physical mechanisms.


Asunto(s)
Luz , Resonancia por Plasmón de Superficie/métodos , Troponina I/análisis , Diseño de Equipo , Humanos , Dispersión de Radiación , Resonancia por Plasmón de Superficie/instrumentación
17.
Int J Cancer ; 136(4): 743-51, 2015 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-24469881

RESUMEN

Accurate detection of lymph node metastases is critical for many solid tumours to guide treatment strategies and determine prognostic outcomes. The gold standard for detection of metastasis is by histological analysis of formalin-fixed paraffin-embedded (FFPE) sections of removed lymph nodes; this analysis method has remained largely unchanged for decades. Recent studies have highlighted limitations in the sensitivity of this approach, at least in its current clinical use, to detect very small metastatic deposits. Importantly, the poor prognostic outcomes associated with the presence of such small tumour deposits are now well established in a number of cancers. In addition, histological analysis of FFPE sections cannot be used practically for intraoperative node assessment. Novel lymph node staging technologies are therefore actively being developed. This review critically presents the main advances in this field and discusses why these technologies have not been able to provide a better alternative to the current gold standard diagnostic technique.


Asunto(s)
Estadificación de Neoplasias/métodos , Neoplasias/patología , Humanos , Periodo Intraoperatorio , Metástasis Linfática , Técnicas de Diagnóstico Molecular , Neoplasias/cirugía , Periodo Preoperatorio
18.
Mol Med ; 21 Suppl 1: S25-31, 2015 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-26605644

RESUMEN

Circulating tumor cells (CTC) may be defined as tumor- or metastasis-derived cells that are present in the bloodstream. The CTC pool in colorectal cancer (CRC) patients may include not only epithelial tumor cells, but also tumor cells undergoing epithelial-mesenchymal transition (EMT) and tumor stem cells. A significant number of patients diagnosed with early stage CRC subsequently relapse with recurrent or metastatic disease despite undergoing "curative" resection of their primary tumor. This suggests that an occult metastatic disease process was already underway, with viable tumor cells being shed from the primary tumor site, at least some of which have proliferative and metastatic potential and the ability to survive in the bloodstream. Such tumor cells are considered to be responsible for disease relapse in these patients. Their detection in peripheral blood at the time of diagnosis or after resection of the primary tumor may identify those early-stage patients who are at risk of developing recurrent or metastatic disease and who would benefit from adjuvant therapy. CTC may also be a useful adjunct to radiological assessment of tumor response to therapy. Over the last 20 years many approaches have been developed for the isolation and characterization of CTC. However, none of these methods can be considered the gold standard for detection of the entire pool of CTC. Recently our group has developed novel unbiased inertial microfluidics to enrich for CTC, followed by identification of CTC by imaging flow cytometry. Here, we provide a review of progress on CTC detection and clinical significance over the last 20 years.


Asunto(s)
Separación Celular/métodos , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/historia , Transición Epitelial-Mesenquimal/genética , Células Neoplásicas Circulantes/patología , Células Madre Neoplásicas/patología , Factores de Transcripción con Motivo Hélice-Asa-Hélice Básico/genética , Factores de Transcripción con Motivo Hélice-Asa-Hélice Básico/metabolismo , Biomarcadores/metabolismo , Separación Celular/instrumentación , Neoplasias Colorrectales/genética , Neoplasias Colorrectales/patología , Células Epiteliales/metabolismo , Células Epiteliales/patología , Expresión Génica , Factor Estimulante de Colonias de Granulocitos/genética , Factor Estimulante de Colonias de Granulocitos/metabolismo , Historia del Siglo XX , Historia del Siglo XXI , Humanos , Microfluídica/instrumentación , Células Neoplásicas Circulantes/metabolismo , Células Madre Neoplásicas/metabolismo , Pronóstico , Receptores Acoplados a Proteínas G/genética , Receptores Acoplados a Proteínas G/metabolismo , Recurrencia
19.
Anal Chem ; 87(21): 10693-7, 2015 Nov 03.
Artículo en Inglés | MEDLINE | ID: mdl-26461268

RESUMEN

Internalized gold nanoparticles were quantified in large numbers of individual prostate cancer cells using large area synchrotron X-ray fluorescence microscopy. Cells were also irradiated with a 6 MV linear accelerator to assess the biological consequence of radiosensitization with gold nanoparticles. A large degree of heterogeneity in nanoparticle uptake between cells resulted in influenced biological effect.


Asunto(s)
Células/efectos de la radiación , Fluorescencia , Luz , Nanopartículas del Metal/química , Células/efectos de los fármacos , Oro/química , Humanos , Masculino , Neoplasias de la Próstata/tratamiento farmacológico , Rayos X
20.
Anal Chem ; 87(3): 1456-61, 2015 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-25495915

RESUMEN

Long-range surface plasmon resonance (LRSPR) is a powerful biosensing technology due to a substantially larger probing depth into the medium and sensitivity, compared with conventional SPR. We demonstrate here that LRSPR can provide sensitive noninvasive measurement of the dynamic fluctuation of adherent cells, often referred to as the cellular micromotion. Proof of concept was achieved using confluent layers of 3T3 fibroblast cells and MDA-MB-231 cancer cells. The slope of the power spectral density (PSD) of the optical fluctuations was calculated to determine the micromotion index, and significant differences were measured between live and fixed cell layers. Furthermore, the performances of LRSPR and conventional surface plasmon resonance (cSPR) were compared with respect to micromotion monitoring. Our study showed that the micromotion index of cells measured by LRSPR sensors was higher than when measured with cSPR, suggesting a higher sensitivity of LRSPR to the micromotion of cells. To investigate further this finding, simulations were conducted to establish the relative sensitivities of LRSPR and cSPR to membrane fluctuations. Increased signal intensity was predicted for LRSPR in comparison to cSPR, suggesting that membrane fluctuations play a significant role in the optical micromotion measured in LRSPR. Analogous to cellular micromotion measured using impedance techniques, LRSPR micromotion has the potential to provide important biological information on the metabolic activity and viability of adherent cells.


Asunto(s)
Movimiento Celular , Resonancia por Plasmón de Superficie/métodos , Células 3T3 , Animales , Adhesión Celular , Línea Celular Tumoral , Humanos , Ratones
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA