Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Circulation ; 149(10): 734-743, 2024 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-37874908

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is common in patients undergoing transcatheter aortic valve replacement (TAVR) and is associated with increased risk of bleeding and stroke. While left atrial appendage occlusion (LAAO) is approved as an alternative to anticoagulants for stroke prevention in patients with AF, placement of these devices in patients with severe aortic stenosis, or when performed at the same time as TAVR, has not been extensively studied. METHODS: WATCH-TAVR (WATCHMAN for Patients with AF Undergoing TAVR) was a multicenter, randomized trial evaluating the safety and effectiveness of concomitant TAVR and LAAO with WATCHMAN in AF patients. Patients were randomized 1:1 to TAVR + LAAO or TAVR + medical therapy. WATCHMAN patients received anticoagulation for 45 days followed by dual antiplatelet therapy until 6 months. Anticoagulation was per treating physician preference for patients randomized to TAVR + medical therapy. The primary noninferiority end point was all-cause mortality, stroke, and major bleeding at 2 years between the 2 strategies. RESULTS: The study enrolled 349 patients (177 TAVR + LAAO and 172 TAVR + medical therapy) between December 2017 and November 2020 at 34 US centers. The mean age of patients was 81 years, and the mean scores for CHA2DS2-VASc and HAS-BLED (Hypertension, Abnormal renal/liver function, Stroke, Bleeding history or predisposition, Labile INR, Elderly, Drugs/alcohol concomitantly) were 4.9 and 3.0, respectively. At baseline, 85.4% of patients were taking anticoagulants and 71.3% patients were on antiplatelet therapy. The cohorts were well-balanced for baseline characteristics. The incremental LAAO procedure time was 38 minutes, and the median contrast volume used for combined procedures was 119 mL versus 70 mL with TAVR alone. At the 24-month follow-up, 82.5% compared with 50.8% of patients were on any antiplatelet therapy, and 13.9% compared with 66.7% of patients were on any anticoagulation therapy in TAVR + LAAO compared with TAVR + medical therapy group, respectively. For the composite primary end point, TAVR + LAAO was noninferior to TAVR + medical therapy (22.7 versus 27.3 events per 100 patient-years for TAVR + LAAO and TAVR + medical therapy, respectively; hazard ratio, 0.86 [95% CI, 0.60-1.22]; Pnoninferiority<0.001). CONCLUSIONS: Concomitant WATCHMAN LAAO and TAVR is noninferior to TAVR with medical therapy in severe aortic stenosis patients with AF. The increased complexity and risks of the combined procedure should be considered when concomitant LAAO is viewed as an alternative to medical therapy for patients with AF undergoing TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03173534.


Asunto(s)
Estenosis de la Válvula Aórtica , Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Apéndice Atrial/cirugía , Accidente Cerebrovascular/epidemiología , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Hemorragia/inducido químicamente , Anticoagulantes/efectos adversos , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento
2.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artículo en Inglés | MEDLINE | ID: mdl-38552656

RESUMEN

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Adolescente , Adulto , Anciano , Femenino , Humanos , Masculino , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
3.
J Card Fail ; 30(1): 95-99, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37625582

RESUMEN

BACKGROUND: Aortic regurgitation (AR) is a common complication following left ventricular assist device (LVAD) implantation. We evaluated the hemodynamic implications of AR in patients with HeartMate 3 (HM3) LVAD at baseline and in response to speed changes. METHODS AND RESULTS: Clinically stable outpatients supported by HM3 who underwent a routine hemodynamic ramp test were retrospectively enrolled in this analysis. Patients were stratified based on the presence of at least mild AR at baseline speed. Hemodynamic and echocardiographic parameters were compared between the AR and non-AR groups. Sixty-two patients were identified. At the baseline LVAD speed, 29 patients (47%) had AR, while 33 patients (53%) did not. Patients with AR were older and supported on HM3 for a longer duration. At baseline speed, all hemodynamic parameters were similar between the groups including central venous pressure, pulmonary capillary wedge pressure, pulmonary arterial pressures, cardiac output and index, and pulmonary artery pulsatility index (p > 0.05 for all). During the subacute assessment, AR worsened in some, but not all, patients, with increases in LVAD speed. There were no significant differences in 1-year mortality or hospitalization rates between the groups, however, at 1-year, ≥ moderate AR and right ventricular failure (RVF) were detected in higher rates among the AR group compared to the non-AR group (45% vs. 0%; p < 0.01, and 75% vs. 36.8%; p = 0.02, respectively). CONCLUSIONS: In a cohort of stable outpatients supported with HM3 who underwent a routine hemodynamic ramp test, the presence of mild or greater AR did not impact the ability of HM3 LVADs to effectively unload the left ventricle during early subacute assessment. Although the presence of AR did not affect mortality and hospitalization rates, it resulted in higher rates of late hemodynamic-related events in the form of progressive AR and RVF.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Insuficiencia Cardíaca , Corazón Auxiliar , Humanos , Estudios Retrospectivos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/cirugía , Corazón Auxiliar/efectos adversos , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Hemodinámica/fisiología
4.
Catheter Cardiovasc Interv ; 103(2): 367-375, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-37890014

RESUMEN

AIMS: Characterize the impact of residual tricuspid regurgitation (TR) on right ventricle (RV) remodeling and clinical outcomes after transcatheter tricuspid valve intervention. METHODS: We performed a single-center retrospective analysis of transcatheter tricuspid valve repair (TTVr) or replacement (TTVR) patients. The primary outcomes were longitudinal tricuspid annular plane systolic excursion (TAPSE), fractional area change (FAC), pulmonary artery systolic pressure (PASP), and RV dimensions (RVd). We used multivariable linear mixed models to evaluate association with replacement versus repair and degree of TR reduction with changes in these echo measures over time. Multivariable Cox regression was used to identify associations between changes in these echo measures and a composite clinical outcome of death, heart failure hospitalization, or re-do tricuspid valve intervention. RESULTS: We included a total of 61 patients; mean age was 77.5 ± 11.7 and 62% were female. TTVR was performed in 25 (41%) and TTVr in 36 (59%). Initially, 72% (n = 44) had ≤ severe TR and 28% (n = 17) had massive or torrential TR. The median number of follow up echos was 2: time to 1st follow-up was 50 days (interquartile range [IQR]: 20, 91) and last follow-up was 147 (IQR: 90, 327). Median TR reduction was 1 (IQR: 0, 2) versus 4 (IQR: 3, 6) grades in TTVr versus TTVR (p < 0.0001). In linear mixed modeling, TTVR was associated with decline in TAPSE and PASP, and TR reduction was associated with decreased RVd. In multivariable Cox regression, greater RVd was associated with the clinical outcome (hazard ratio: 9.27, 95% confidence interval: 1.23-69.88, p = 0.03). CONCLUSION: Greater TR reduction is achieved by TTVR versus TTVr, which is in turn associated with RV reverse remodeling. RV dimension in follow-up is associated with increased risk of a composite outcome of death, heart failure hospitalization, or re-do tricuspid valve intervention.


Asunto(s)
Insuficiencia Cardíaca , Insuficiencia de la Válvula Tricúspide , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Masculino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Estudios Retrospectivos , Remodelación Ventricular , Resultado del Tratamiento , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/terapia
5.
Catheter Cardiovasc Interv ; 102(2): 328-338, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37393603

RESUMEN

BACKGROUND: Valve-in-valve (VIV) transcatheter aortic valve implantation (TAVI) is a less invasive therapeutic option compared with redo surgical valve replacement for high-risk patients. Relative to procedures within stented surgical valves, VIV-TAVI within stentless valves is associated with a higher complication rate due to challenging underlying anatomy and absence of fluoroscopic landmarks. AIMS: We share a single-center experience with VIV-TAVI in stentless valves, discussing our procedural insights and associated outcomes. METHODS: Our institutional database was queried, and 25 patients who had undergone VIV-TAVI within a stentless bioprosthesis, homograft, or valve-sparing aortic root replacement between 2013 and 2022 were found. Outcome endpoints were based on the Valve Academic Research Consortium-3 criteria. RESULTS: The mean age of the cohort was 69.5 ± 13.6 years. VIV implantation was performed within a homograft in 11 patients, a stentless bioprothesis in 10 patients, and a valve-sparing aortic root replacement in 4 patients. Nineteen (76%) balloon-expandable valves, 5 (20%) self-expanding valves, and one mechanically-expandable (4%) valve were implanted with 100% procedural success, with no instances of significant paravalvular leak, coronary occlusion, or device embolization. There was one (4%) in-hospitality mortality after an emergency procedure; one (4%) patient experienced a transient ischemic attack; and two (8%) patients required permanent pacemaker implantation. The median length of hospital stay was 2 days. After a median follow-up time of 16.5 months, valve function was acceptable in all patients with available data. CONCLUSION: VIV-TAVI within stentless valves can be safely performed with methodical procedural technique and can provide clinical benefit in patients at high reoperation risk.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Resultado del Tratamiento , Diseño de Prótesis , Estenosis de la Válvula Aórtica/cirugía
6.
Catheter Cardiovasc Interv ; 99(5): 1668-1678, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35066989

RESUMEN

OBJECTIVE: The objective of this study was to evaluate the incidence of and risk factors associated with cardiogenic shock (CS) following surgery versus transcatheter tricuspid valve intervention (TTVI) for tricuspid regurgitation (TR). BACKGROUND: Surgical therapy for TR is associated with high rates of CS. Postprocedural shock has not been studied following TTVI. METHODS: We performed a single-center retrospective analysis of isolated tricuspid valve (TV) surgery or TTVI for TR. The primary outcome was postprocedural class D or E CS according to Society for Cardiovascular Angiography and Interventions (SCAI) CS classification scheme, and secondary outcome was in-hospital mortality. Multivariable logistic regression modeling was performed for primary and secondary outcomes. Support vector machine analysis was performed for sensitivity analysis. RESULTS: From 2008 to 2020, a total of 122 patients underwent isolated TV surgery (n = 58, 14 TV repair, and 44 TV replacement) or TTVI (n = 64, 36 TV repair, and 28 TV replacement). Surgical patients were significantly younger than TTVI patients (67.5 vs. 80 years, p < 0.0001). Multivariable modeling revealed an association between the primary outcome and surgery (odds ratio [OR]: 8.75, 95% confidence interval [CI]: 2.83, 27.03, p = 0.0002), as well as baseline central venous pressure (CVP, OR: 1.12, 95% CI: 1.02, 1.22, p = 0.016). Additionally, class DE CS was independently associated with in-hospital mortality (OR: 5.21, 1.35, 20.09, p = 0.016). CVP and surgery were found to have highest importance indices in support vector machine analysis. CONCLUSION: In patients undergoing TV intervention for TR, surgery versus TTVI and elevated CVP are associated with advanced postprocedural CS. Patients developing advanced CS are at increased risk of in-hospital mortality.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Incidencia , Estudios Retrospectivos , Choque Cardiogénico/diagnóstico , Choque Cardiogénico/epidemiología , Choque Cardiogénico/terapia , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/etiología , Insuficiencia de la Válvula Tricúspide/cirugía
7.
Catheter Cardiovasc Interv ; 99(4): 1206-1213, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35084101

RESUMEN

To highlight the trends of surgical (open) aortic valve replacement (SAVR) as well as to compare the outcome between transcatheter aortic valve replacement (TAVR) and SAVR in elderly dialysis patients. TAVR has evolved as an effective alternative to surgery (SAVR) for aortic stenosis. We identified dialysis-dependent patients who underwent SAVR or TAVR from 2000 to 2015 from the United States Renal Data System using ICD-9 codes. We defined high-risk surgical patients as age over 70 or older. The primary endpoint was survival at 3 years and we compared the outcome between SAVR and TAVR groups using inverse probability of treatment weighting (IPTW). A total of 4332 and 1280 dialysis patients underwent SAVR and TAVR, respectively, during the study period. Among SAVR cohort, 3312 patients underwent SAVR before June 2012 and 1020 after June 2012. In-hospital mortality was significantly worse before 2012 (14.6% vs. 11.3% after 2012, p = 0.007) as well as estimated 3-year mortality (69.1% vs. 60.3% after 2012, p < 0.001). After June 2012, the TAVR cohort was older and had more comorbidities including coronary artery disease and congestive heart failure compared to the SAVR cohort. After IPTW, in-hospital mortality was significantly lower after TAVR versus SAVR (odds ratio 0.38 [95% confidence interval [CI], 0.27-0.52], p < 0.001). However, TAVR had a significantly higher risk of 3-year mortality than SAVR (hazard ratio 1.24 [95% CI 1.1-1.39], p < 0.001). TAVR may be a reasonable and potentially preferable alternative to SAVR in the elderly dialysis population in the short-term period.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Diálisis Renal/efectos adversos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Estados Unidos/epidemiología
8.
Catheter Cardiovasc Interv ; 99(4): 1268-1276, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35084803

RESUMEN

OBJECTIVES: The purpose of this study was to characterize the anatomic relationship between the inferior vena cava (IVC) and tricuspid annulus (TA) and its potential impact on the performance of transcatheter TV interventions. BACKGROUND: Transcatheter tricuspid valve (TV) interventions are emerging as a therapeutic alternative for the treatment of severe, symptomatic tricuspid regurgitation (TR). Progression of TR is associated with right heart dilatation. These anatomic changes may distort the IVC-TA relationship and impact successful implantation of transcatheter devices. METHODS: Fifty patients who presented with symptomatic TR for consideration of transcatheter TV therapy with an available CT were included in the study. Comprehensive transesophageal echocardiogram and CT analyses were performed to assess the right-sided cardiac chambers, TA and IVC-TA relationship. RESULTS: The mean age of the study cohort was 78.4 ± 8.9 years. Torrential TR was present in 54% (n = 27). There was considerable variation in the short axis mid-IVC to mid-TA offset (SAXMID 18.2 ± 7.9 mm, range 4.7-42.1 mm). CONCLUSIONS: The IVC-to-TA relationship exhibits significant variability in patients with symptomatic TR. CT analysis of the tricuspid anatomy, including the relationship to the surrounding structures and the IVC, is essential for planning transcatheter TV interventions. Further studies are needed to define whether the IVC-to-TA relationship is a predictor of technical success in the context of specific transcatheter delivery systems.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Anciano , Anciano de 80 o más Años , Humanos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Vena Cava Inferior/diagnóstico por imagen
9.
Catheter Cardiovasc Interv ; 97(2): 201-205, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-32415916

RESUMEN

BACKGROUND: The healthcare burden posed by the coronavirus disease 2019 (COVID-19) pandemic in the New York Metropolitan area has necessitated the postponement of elective procedures resulting in a marked reduction in cardiac catheterization laboratory (CCL) volumes with a potential to impact interventional cardiology (IC) fellowship training. METHODS: We conducted a web-based survey sent electronically to 21 Accreditation Council for Graduate Medical Education accredited IC fellowship program directors (PDs) and their respective fellows. RESULTS: Fourteen programs (67%) responded to the survey and all acknowledged a significant decrease in CCL procedural volumes. More than half of the PDs reported part of their CCL being converted to inpatient units and IC fellows being redeployed to COVID-19 related duties. More than two-thirds of PDs believed that the COVID-19 pandemic would have a moderate (57%) or severe (14%) adverse impact on IC fellowship training, and 21% of the PDs expected their current fellows' average percutaneous coronary intervention (PCI) volume to be below 250. Of 25 IC fellow respondents, 95% expressed concern that the pandemic would have a moderate (72%) or severe (24%) adverse impact on their fellowship training, and nearly one-fourth of fellows reported performing fewer than 250 PCIs as of March 1st. Finally, roughly one-third of PDs and IC fellows felt that there should be consideration of an extension of fellowship training or a period of early career mentorship after fellowship. CONCLUSIONS: The COVID-19 pandemic has caused a significant reduction in CCL procedural volumes that is impacting IC fellowship training in the NY metropolitan area. These results should inform professional societies and accreditation bodies to offer tailored opportunities for remediation of affected trainees.


Asunto(s)
COVID-19/epidemiología , Cateterismo Cardíaco , Cardiología/educación , Educación de Postgrado en Medicina/organización & administración , Becas/organización & administración , Intervención Coronaria Percutánea/educación , Acreditación , Humanos , New Jersey , Ciudad de Nueva York , Ejecutivos Médicos , Encuestas y Cuestionarios
10.
Eur Heart J ; 41(8): 958-969, 2020 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-31883339

RESUMEN

AIMS: B-type natriuretic peptide (BNP) is a cardiac neurohormone that is secreted in response to ventricular volume expansion and pressure overload. There are conflicting data regarding the association between BNP levels and outcomes after transcatheter aortic valve replacement (TAVR). We therefore sought to assess the association between baseline BNP and adverse outcomes in patients with symptomatic, severe aortic stenosis (AS), and left ventricular ejection fraction (LVEF) ≥50%, undergoing TAVR in the PARTNER 2 Trial and Registry. METHODS AND RESULTS: A total of 1782 patients were included in the analysis, and BNP was evaluated both as a continuous log-transformed value and by a priori categories: low (<50 pg/mL), normal (≥50 and <100 pg/mL), moderately elevated (≥100 and <400 pg/mL), or markedly elevated (≥400 pg/mL). Clinical outcomes from discharge to 2 years were compared between patients according to their baseline BNP level, using Kaplan-Meier event rates and multivariable Cox proportional hazards regression models. After adjustment, spline curves revealed a non-linear association between log-transformed BNP and all-cause and cardiovascular mortality in which both the lowest and highest values were associated with increased mortality. Two-year all-cause mortality rates for those with low (n = 86), normal (n = 202), moderately elevated (n = 885), and markedly elevated (n = 609) baseline BNP were 20.0%, 9.8%, 17.7%, and 26.1%, respectively. In adjusted models, compared to a normal baseline BNP, low [adjusted hazard ratio (HR) 2.6, 95% confidence interval (CI) 1.3-5.0, P-value 0.005], moderately elevated (adjusted HR 1.6, 95% CI 1.0-2.6, P-value 0.06), and markedly elevated (adjusted HR 2.1, 95% CI 1.3-3.5, P-value 0.003) BNP were associated with increased all-cause mortality, driven by cardiovascular mortality. CONCLUSIONS: In a large cohort of patients with severe symptomatic AS and preserved LVEF undergoing TAVR, all-cause and cardiovascular mortality rates at 2 years were higher in patients with low and markedly elevated BNP levels. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ unique identifier #NCT01314313, #NCT02184442, #NCT03222128, and #NCT03222141.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Péptido Natriurético Encefálico , Sistema de Registros , Factores de Riesgo , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
11.
Eur Heart J ; 41(8): 943-954, 2020 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-31711153

RESUMEN

AIMS: Left ventricular pressure overload is associated with activation of the cardiac renin-angiotensin system, which may contribute to myocardial fibrosis and worse clinical outcomes. We sought to assess the association between treatment with angiotensin-converting enzyme inhibitors (ACEIs) or angiotensin II receptor blockers (ARBs) at baseline and clinical outcomes in patients with symptomatic, severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) in the PARTNER 2 trial and registries. METHODS AND RESULTS: A total of 3979 intermediate, high, or prohibitive risk patients who underwent TAVR in the PARTNER 2 trial and registries (excluding the valve in valve registry) were included in the study. Clinical outcomes at 2 years were compared according to baseline ACEI/ARB treatment status using Kaplan-Meier event rates and study-stratified multivariable Cox proportional hazards regression models. Sensitivity analysis was conducted using propensity score matching. Of 3979 patients who were included in the current analysis, 1736 (43.6%) were treated and 2243 (56.4%) were not treated with ACEI/ARB at baseline. Treatment with ACEI/ARB was associated with lower 2-year all-cause mortality (18.6% vs. 27.5%, P < 0.0001), cardiovascular mortality (12.3% vs. 17.9%, P < 0.0001), and non-cardiovascular mortality (7.2% vs. 11.7%, P < 0.0001). Angiotensin-converting enzyme inhibitor/ARB treatment at baseline remained independently associated with a lower hazard of 2-year all-cause and cardiovascular mortality after multivariable adjustment, and propensity score matching. CONCLUSION: In a large cohort of patients with severe symptomatic AS from the PARTNER 2 trial and registries, ACEI/ARB treatment at baseline was independently associated with a lower risk of 2-year all-cause and cardiovascular mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Antagonistas de Receptores de Angiotensina/uso terapéutico , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Sistema de Registros , Sistema Renina-Angiotensina , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
12.
Catheter Cardiovasc Interv ; 95(6): 1178-1183, 2020 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-31452322

RESUMEN

OBJECTIVES: To describe outcomes after suprasternal (SS) transcatheter aortic valve replacement (TAVR) as a new alternative access approach. BACKGROUND: There still remains a cohort of the TAVR population who are not suitable for a transfemoral (TF) approach. SS-TAVR is a safe and effective alternative to TF-TAVR and has now become our preferred alternative access route. METHODS: We retrospectively reviewed all patients from New York Presbyterian Hospital, Columbia University Medical Center and Princeton Baptist Medical Center who underwent SS-TAVR from 2015 to July 2018. A total of 84 patients were included in the study. RESULTS: Technical success was achieved in all cases. Thirty-day survival was 98.8% (n = 83). There were minimal complications. Most notably, there were no transient ischemic attacks or strokes (0%, n = 0). Reexploration for bleeding was 3.6% (n = 3), and major bleeding was 1.7% (n = 1). We also achieved satisfactory results with a mean aortic valve gradient of 6.07 ± 3.79 mmHg and an aortic valve area of 2.21 ± 0.51 cm2 . No patients had anything more than mild paravalvular leak. The mean length of stay (LOS) in the intensive care unit was 1.42 ± 1.23 days, and hospital LOS was 4.20 ± 3.29 days. CONCLUSIONS: SS access for TAVR is an extremely important technique to have in any valve team's alternative access armamentarium. This technique can be safely and reliably reproduced with any standard hybrid operating room setup and no additional equipment, and it can be used with any commercially available valve system. In the current experience, minimal complications and excellent early term results were obtained.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Alabama , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Hemodinámica , Humanos , Masculino , Ciudad de Nueva York , Complicaciones Posoperatorias/etiología , Recuperación de la Función , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
13.
J Cardiovasc Electrophysiol ; 30(4): 461-467, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30585678

RESUMEN

INTRODUCTION: Percutaneous left atrial appendage closure (LAAC) is typically performed utilizing transesophageal echocardiography (TEE) and fluoroscopy. Intracardiac echocardiography (ICE) can be a suitable alternative to guide implantation. Given the limited data, we performed a meta-analysis of all studies that compared ICE vs TEE for percutaneous LAAC. METHODS: A comprehensive literature search was performed in PubMed, Embase, Scopus, Google Scholar, and major scientific conference sessions for published abstracts and manuscripts until 1 August 2018. Studies reporting clinical outcomes comparing TEE vs ICE for endocardial LAAC in human subjects aged greater than or equal to 18 years were included. Two investigators independently extracted the data and individual quality assessment was performed. The analysis was performed using Cochrane Collaboration software, RevMan 5.3. RESULTS: Five eligible studies consisting of 1157 patients (ICE-391 patients and TEE-766 patients) were included. Four studies were retrospective and one was prospective, nonrandomized. Two studies included Watchman, two included the Amplatzer Cardiac Plug/Amulet device, and one included both devices. There was no significant difference in CHA2DS2VASC or HAS-BLED scores between both groups. There was no significant difference in acute procedural success between ICE vs TEE (risk ratio, 1.01; 95% CI, 0.99-1.04; P = 0.24). There was no significant difference in fluoroscopy time (mean difference [MD], 1.84 minutes; 95% CI, 0.59-4.27; P = 0.14) and total procedure time (MD, -5.06 minutes; 95% CI, -24.6-14.4; P = 0.61) between both groups. There was also no significant difference in complications including pericardial tamponade, device embolization, and stroke between both groups. CONCLUSION: In our meta-analysis, ICE was as effective as TEE during percutaneous LAAC.


Asunto(s)
Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Cateterismo Cardíaco , Ecocardiografía Transesofágica , Anciano , Apéndice Atrial/fisiopatología , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Resultado del Tratamiento
14.
Eur Heart J ; 38(38): 2879-2887, 2017 Oct 07.
Artículo en Inglés | MEDLINE | ID: mdl-29019612

RESUMEN

AIMS: Transthyretin cardiac amyloidosis (ATTR-CA) has been reported in patients with aortic stenosis (AS) but its prevalence and phenotype are not known. We examine elderly patients with severe symptomatic AS undergoing transcatheter aortic valve replacement (TAVR) and determine the prevalence and phenotype of ATTR-CA non-invasively. METHODS AND RESULTS: We performed technetium-99m pyrophosphate (99mTc-PYP) cardiac scintigraphy prospectively on patients who underwent TAVR, to screen for ATTR-CA. Transthoracic echocardiography and speckle-strain imaging were performed. We assessed the association of several parameters with ATTR-CA using multivariable logistic regression and constructed receiver operating curves to evaluate the best predictors of ATTR-CA. Among 151 patients (mean age 84 ± 6 years, 68% men), 16% (n = 24) screened positive for ATTR-CA with 99mTc-PYP scintigraphy. Compared with patients without ATTR-CA, ATTR-CA patients had a thicker interventricular septum (1.3 vs. 1.1 cm, P = 0.007), higher left ventricular (LV) mass index (130 vs. 98 g/m2, P = 0.002), and lower stroke volume index (30 vs. 36 mL/m2, P = 0.009). ATTR-CA patients had advanced diastolic dysfunction with higher E/A ratio (2.3 vs. 0.9, P = 0.001) and lower deceleration time (176 vs. 257 ms, P < 0.0001); impairment in systolic function with lower ejection fraction (48% vs. 56%, P = 0.011), myocardial contraction fraction (26 vs. 41, P < 0.0001), and average of lateral and septal mitral annular tissue Doppler S' (4.0 vs. 6.6 cm/s, P < 0.0001). While ATTR-CA patients had more impaired global longitudinal strain (-12 vs. -16%, P = 0.007), relative apical longitudinal strain was the same regardless of ATTR-CA diagnosis (0.98 vs. 0.98, P = 0.991). Average S' best predicted ATTR-CA in multivariable logistic regression (odds ratio 16.67 per 1 cm/s decrease with AUC 0.96, 95% confidence interval 0.90-0.99, P = 0.002) with a value ≤6 conferring 100% sensitivity for predicting a positive 99mTc-PYP amyloid scan. CONCLUSIONS: Transthyretin cardiac amyloidosis is prevalent in 16% of patients with severe calcific AS undergoing TAVR and is associated with a severe AS phenotype of low-flow low-gradient with mildly reduced ejection fraction. Average tissue Doppler mitral annular S' of < 6 cm/s may be a sensitive measure that should prompt a confirmatory 99mTc-PYP scan and subsequent testing for ATTR-CA. Prospective assessment of outcomes after TAVR is needed in patients with and without ATTR-CA.


Asunto(s)
Neuropatías Amiloides Familiares/complicaciones , Estenosis de la Válvula Aórtica/complicaciones , Cardiomiopatías/complicaciones , Calcificación Vascular/complicaciones , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/cirugía , Ecocardiografía , Femenino , Humanos , Masculino , Fenotipo , Estudios Prospectivos , Cintigrafía , Radiofármacos , Volumen Sistólico/fisiología , Pirofosfato de Tecnecio Tc 99m , Reemplazo de la Válvula Aórtica Transcatéter , Calcificación Vascular/cirugía , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/fisiopatología
15.
Circulation ; 133(10): 954-66, 2016 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-26826180

RESUMEN

BACKGROUND: Fingolimod, a sphingosine-1-phosphate receptor agonist, is used for the treatment of multiple sclerosis and exerts antiapoptotic properties. We hypothesized that sphingosine-1-phosphate receptor activation with fingolimod during acute myocardial infarction (MI) inhibits apoptosis, leading to increased myocardial salvage, reduced infarct size, and mitigated left ventricular (LV) remodeling in a porcine model of ischemia/reperfusion. METHODS AND RESULTS: Ischemia/reperfusion was induced in pigs by balloon occlusion of the left anterior descending artery, followed by reperfusion. Animals randomly received fingolimod or saline (control). In short-term experiments, fingolimod treatment activated the cardioprotective reperfusion injury salvage kinase and survivor activating factor enhancement pathways in the infarct border zone 24 hours after MI, leading to decreased cardiomyocyte apoptosis and reduced myocardial oxidative stress. These effects were abolished by specific inhibitors of both pathways, demonstrating that fingolimod-induced cardioprotection was mediated by reperfusion injury salvage kinase and survivor activating factor enhancement pathways. In long-term experiments, fingolimod significantly improved myocardial salvage, reduced infarct size, and improved systolic LV function measured by cardiac magnetic resonance 1 week and 1 month after MI. Importantly, fingolimod mitigated the development of adverse post-MI LV remodeling 1 month after MI. Specifically, fingolimod treatment led to a significant reduction in LV mass, LV dilatation, and neurohormonal activation, and it preserved LV geometry. Furthermore, fingolimod decreased interstitial fibrosis, cardiomyocyte hypertrophy, and chronic activation of Akt and extracellular receptor kinase 1/2 in the remote noninfarcted myocardium. CONCLUSIONS: Sphingosine-1-phosphate receptor activation with fingolimod during acute MI reduced infarct size via the reperfusion injury salvage kinase and survivor activating factor enhancement pathways, improved systolic LV function, and mitigated post-MI LV remodeling. Our data strongly support a cardioprotective role for sphingosine-1-phosphate receptor activation during MI.


Asunto(s)
Clorhidrato de Fingolimod/uso terapéutico , Infarto del Miocardio/tratamiento farmacológico , Daño por Reperfusión Miocárdica/tratamiento farmacológico , Receptores de Lisoesfingolípidos/agonistas , Terapia Recuperativa/métodos , Remodelación Ventricular/efectos de los fármacos , Animales , Modelos Animales de Enfermedad , Clorhidrato de Fingolimod/farmacología , Infarto del Miocardio/metabolismo , Infarto del Miocardio/patología , Daño por Reperfusión Miocárdica/metabolismo , Daño por Reperfusión Miocárdica/patología , Receptores de Lisoesfingolípidos/metabolismo , Porcinos , Remodelación Ventricular/fisiología
16.
Am J Physiol Endocrinol Metab ; 310(9): E774-81, 2016 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-26979523

RESUMEN

The incretin effect reflects the actions of enteral stimuli to promote prandial insulin secretion. Impairment of this measure has been proposed as an early marker of ß-cell dysfunction and described in T2D, IGT, and even obesity without IGT. We sought to determine the effects of obesity and diabetes on the incretin effect in young subjects with short exposures to metabolic abnormalities and a few other confounding medical conditions. Subjects with T2D (n = 10; 18.0 ± 0.4 yr) or NGT, either obese (n = 11; 17.7 ± 0.4 yr) or lean (n = 8; 26.5 ± 2.3 yr), had OGTT and iso-iv. The incretin effect was calculated as the difference in insulin secretion during these tests and was decreased ∼50% in both the NGT-Ob and T2D subjects relative to the NGT-Ln group. The T2D group had impaired glucose tolerance and insulin secretion during the OGTT, whereas the lean and obese NGT subjects had comparable glucose excursions and ß-cell function. During the iso-iv test, the NGT-Ob subjects had significantly greater insulin secretion than the NGT-Ln and T2D groups. These findings demonstrate that in young subjects with early, well-controlled T2D the incretin effect is reduced, similar to what has been described in diabetic adults. The lower incretin effect calculated for the obese subjects with NGT is driven by a disproportionately greater insulin response to iv glucose and does not affect postprandial glucose regulation. These findings confirm that the incretin effect is an early marker of impaired insulin secretion in persons with abnormal glucose tolerance but suggest that in obese subjects with NGT the incretin effect calculation can be confounded by exaggerated insulin secretion to iv glucose.


Asunto(s)
Glucemia/metabolismo , Diabetes Mellitus Tipo 2/metabolismo , Incretinas/metabolismo , Insulina/sangre , Obesidad/metabolismo , Adolescente , Estudios de Casos y Controles , Femenino , Prueba de Tolerancia a la Glucosa , Humanos , Insulina/metabolismo , Resistencia a la Insulina , Secreción de Insulina , Masculino , Adulto Joven
17.
Am J Physiol Endocrinol Metab ; 307(9): E784-92, 2014 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-25159330

RESUMEN

Meal-fed (MF) rats with access to food for only 4 consecutive hours during the light cycle learn to eat large meals to maintain energy balance. MF animals develop behavioral and endocrine changes that permit glucose tolerance despite increased meal size. We hypothesized that enhanced activity of the enteroinsular axis mediates glucose homeostasis during MF. Cohorts of rats were allocated to MF or ad libitum (AL) regimens for 2-4 wk. Insulin secretion and glucose tolerance were determined after oral carbohydrate and intraperitoneal (ip) and intravenous (iv) glucose. MF rats ate less than AL in the first week but maintained a comparable weight trajectory thereafter. MF rats had decreased glucose excursions after a liquid mixed meal (AUC: MF 75 ± 7, AL 461 ± 28 mmol·l⁻¹·min, P < 0.001), with left-shifted insulin secretion (AUC(0-15): MF 31.0 ± 4.9, AL 9.6 ± 4.4 pM·min, P < 0.02), which peaked before a significant rise in blood glucose. Both groups had comparable fasting glucagon levels, but postprandial responses were lower with MF. However, neither intestinal expression of proGIP and proglucagon mRNA nor plasma incretin levels differed between MF and AL groups. There were no differences in the insulin response to ip or iv glucose between MF and AL rats. These findings demonstrate that MF improves oral glucose tolerance and is associated with significant changes in postprandial islet hormone secretion. Because MF enhanced ß-cell function during oral but not parenteral carbohydrate administration, and was not accounted for by changes in circulating incretins, these results support a neural mechanism of adaptive insulin secretion.


Asunto(s)
Alostasis , Conducta Alimentaria , Intolerancia a la Glucosa/tratamiento farmacológico , Insulina/metabolismo , Islotes Pancreáticos/metabolismo , Comidas , Sistemas Neurosecretores/fisiopatología , Animales , Conducta Animal , Polipéptido Inhibidor Gástrico/genética , Polipéptido Inhibidor Gástrico/metabolismo , Glucagón/sangre , Glucagón/genética , Glucagón/metabolismo , Intolerancia a la Glucosa/sangre , Intolerancia a la Glucosa/metabolismo , Intolerancia a la Glucosa/fisiopatología , Hiperglucemia/prevención & control , Íleon/metabolismo , Incretinas/sangre , Incretinas/metabolismo , Insulina/sangre , Secreción de Insulina , Mucosa Intestinal/metabolismo , Islotes Pancreáticos/inervación , Yeyuno/metabolismo , Masculino , Especificidad de Órganos , Periodo Posprandial , Proglucagón/genética , Proglucagón/metabolismo , Ratas Long-Evans
18.
Cardiovasc Revasc Med ; 58: 25-30, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37532604

RESUMEN

BACKGROUND: Mitral regurgitation (MR) is the most common valvular heart disease worldwide with a 5-year mortality rate of 50 % with medical therapy alone. Several transcatheter mitral valve replacement (TMVR) devices are being investigated in clinical trials. Early evidence has demonstrated clinical benefits with a reduction in heart failure symptoms, low rates of residual MR, and reverse remodeling of the left ventricle (LV) over time. However, high anatomical screen failure rates limit its applicability. The primary reasons for the anatomical screen failure are risk of LV outflow tract obstruction, large mitral valve annulus size, and the presence of mitral annular calcification. Our clinical experiences using an atrial only fixation TMVR technology delivered via a transfemoral-transseptal approach is described. METHODS: Three consecutive patients with severe functional MR underwent TMVR implantation using an atrial only fixation technology and a low-profile transseptal delivery system. RESULTS: Technical success was achieved in 100 % of the patients with a clinically significant reduction in MR. Longer-term follow-up (up to 6-months) has demonstrated a sustained reduction in MR and significant improvement in quality of life for all patients. CONCLUSIONS: Longer-term outcomes in our patients showed persistent reduction in MR, sustained implant performance, and notable improvements in NYHA Class and quality of life. There were no major adverse events. Follow-up CT data showed no evidence of device-related thrombosis, with stable valve position and integrity. The atrial fixation TMVR technology may have benefits in preserving the dynamics of the native mitral valve annulus thereby reducing the overall risk of LVOT obstruction. SHORT ABSTRACT: We present a single-center experience of three consecutive patients with severe functional MR treated with the AltaValve using a low-profile transseptal delivery system. A clinically significant reduction in mitral regurgitation was achieved in all patients, and longer-term follow-up has demonstrated sustained clinical benefits.


Asunto(s)
Enfermedades de las Válvulas Cardíacas , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/etiología , Calidad de Vida , Cateterismo Cardíaco , Resultado del Tratamiento , Enfermedades de las Válvulas Cardíacas/cirugía
19.
JACC Adv ; 3(3): 100839, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38938839

RESUMEN

Background: Augmented reality (AR) guidance holds potential to improve transcatheter interventions by enabling visualization of and interaction with patient-specific 3-dimensional virtual content. Positioning of cerebral embolic protection devices (CEP) during transcatheter aortic valve replacement (TAVR) increases patient exposure to radiation and iodinated contrast, and increases procedure time. AR may enhance procedural guidance and facilitate a safer intervention. Objectives: The purpose of this study was to develop and test a novel AR guidance system with a custom user interface that displays virtual, patient-specific 3-dimensional anatomic models, and assess its intraprocedural impact during CEP placement in TAVR. Methods: Patients undergoing CEP during TAVR were prospectively enrolled and assigned to either AR guidance or control groups. Primary endpoints were contrast volume used prior to filter placement, times to filter placement, and fluoroscopy time. Postprocedure questionnaires were administered to assess intraprocedural physician experience with AR guidance. Results: A total of 24 patients presenting for TAVR were enrolled in the study (12 with AR guidance and 12 controls). AR guidance eliminated the need for aortic arch angiograms prior to device placement thus reducing contrast volume (0 mL vs 15 mL, P < 0.0001). There was no significant difference in the time required for filter placement or fluoroscopy time. Postprocedure questionnaires indicated that AR guidance increased confidence in wiring of the aortic arch and facilitated easier device placement. Conclusions: We developed a novel AR guidance system that eliminated the need for additional intraprocedural angiograms prior to device placement without any significant difference in time to intervention and offered a subjective improvement in performance of the intervention.

20.
Am J Med ; 137(4): 321-330.e7, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38190959

RESUMEN

PURPOSE: There are concerns that transcatheter or surgical aortic valve replacement (TAVR/SAVR) procedures are preferentially available to White patients. Our objective was to examine differences in utilization of aortic valve replacement and outcomes by race/ethnicity in the US for patients with aortic stenosis. METHODS: We performed a serial cross-sectional cohort study of 299,976 Medicare beneficiaries hospitalized with principal diagnosis of aortic stenosis between 2012 and 2019 stratified by self-reported race/ethnicity (Black, Hispanic, Asian, Native American, and White). Outcomes included aortic valve replacement rates within 6 months of index hospitalization and associated procedural outcomes, including 30-day readmission, 30-day and 1-year mortality. RESULTS: Within 6 months of an index admission for aortic stenosis, 86.8% (122,457 SAVR; 138,026 TAVR) patients underwent aortic valve replacement. Overall, compared with White people, Black (HR 0.87 [0.85-0.89]), Hispanic (0.92 [0.88-0.96]), and Asian (0.95 [0.91-0.99]) people were less likely to receive aortic valve replacement. Among patients who were admitted emergently/urgently, White patients (41.1%, 95% CI, 40.7-41.4) had a significantly higher aortic valve replacement rate compared with Black (29.6%, 95% CI, 28.3-30.9), Hispanic (36.6%, 95% CI, 34.0-39.3), and Asian patients (35.4%, 95% CI, 32.3-38.9). Aortic valve replacement rates increased annually for all race/ethnicities. There were no significant differences in 30-day or 1-year mortality by race/ethnicity. CONCLUSIONS: Aortic valve replacement rates within 6 months of aortic stenosis admission are lower for Black, Hispanic, and Asian people compared to White people. These race-related differences in aortic stenosis treatment reflect complex issues in diagnosis and management, warranting a comprehensive reassessment of the entire care spectrum for disadvantaged populations.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano , Estados Unidos/epidemiología , Válvula Aórtica/cirugía , Estudios Transversales , Medicare , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA