Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
BMC Cardiovasc Disord ; 23(1): 290, 2023 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-37286952

RESUMEN

PURPOSE: Post-operative atrial fibrillation (PoAF) occurs in ~ 30% of patients after cardiac surgery. The etiology of PoAF is complex, but a disbalance in autonomic systems plays an important role. The goal of this study was to assess whether pre-operative heart rate variability analysis can predict the risk of PoAF. METHODS: Patients without a history of AF with an indication for cardiac surgery were included. Two-hour ECG recordings one day before surgery was used for the HRV analysis. Univariate and multivariate logistic regression, including all HRV parameters, their combination, and clinical variables, were calculated to find the best predictive model for post-operative AF. RESULTS: One hundred and thirty-seven patients (33 women) were enrolled in the study. PoAF occurred in 48 patients (35%, AF group); the remaining 89 patients were in the NoAF group. AF patients were significantly older (69.1 ± 8.6 vs. 63.4 ± 10.5 yrs., p = 0.002), and had higher CHA2DS2-VASc score (3 ± 1.4 vs. 2.5 ± 1.3, p = 0.01). In the multivariate regression model, parameters independently associated with higher risk of AF were pNN50, TINN, absolute power VLF, LF and HF, total power, SD2, and the Porta index. A combination of clinical variables with HRV parameters in the ROC analysis achieved an AUC of 0.86, a sensitivity of 0.95, and a specificity of 0.57 and was more effective in PoAF prediction than a combination of clinical variables alone. CONCLUSION: A combination of several HRV parameters is helpful in predicting the risk of PoAF. Attenuation of heart rate variability increases the risk for PoAF.


Asunto(s)
Fibrilación Atrial , Procedimientos Quirúrgicos Cardíacos , Humanos , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/etiología , Frecuencia Cardíaca/fisiología , Factores de Riesgo , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Curva ROC , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología
2.
Eur Heart J Suppl ; 25(Suppl E): E17-E24, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37234235

RESUMEN

Biventricular pacing (Biv) and left bundle branch area pacing (LBBAP) are methods of cardiac resynchronization therapy (CRT). Currently, little is known about how they differ in terms of ventricular activation. This study compared ventricular activation patterns in left bundle branch block (LBBB) heart failure patients using an ultra-high-frequency electrocardiography (UHF-ECG). This was a retrospective analysis including 80 CRT patients from two centres. UHF-ECG data were obtained during LBBB, LBBAP, and Biv. Left bundle branch area pacing patients were divided into non-selective left bundle branch pacing (NSLBBP) or left ventricular septal pacing (LVSP) and into groups with V6 R-wave peak times (V6RWPT) < 90 ms and ≥ 90 ms. Calculated parameters were: e-DYS (time difference between the first and last activation in V1-V8 leads) and Vdmean (average of V1-V8 local depolarization durations). In LBBB patients (n = 80) indicated for CRT, spontaneous rhythms were compared with Biv (39) and LBBAP rhythms (64). Although both Biv and LBBAP significantly reduced QRS duration (QRSd) compared with LBBB (from 172 to 148 and 152 ms, respectively, both P < 0.001), the difference between them was not significant (P = 0.2). Left bundle branch area pacing led to shorter e-DYS (24 ms) than Biv (33 ms; P = 0.008) and shorter Vdmean (53 vs. 59 ms; P = 0.003). No differences in QRSd, e-DYS, or Vdmean were found between NSLBBP, LVSP, and LBBAP with paced V6RWPTs < 90 and ≥ 90 ms. Both Biv CRT and LBBAP significantly reduce ventricular dyssynchrony in CRT patients with LBBB. Left bundle branch area pacing is associated with more physiological ventricular activation.

3.
J Cardiovasc Electrophysiol ; 32(1): 117-125, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33296523

RESUMEN

INTRODUCTION: We aimed to compare the acute differences in left ventricular (LV) function and mechanical synchrony during nonselective His bundle pacing (ns-HBP) versus selective His bundle pacing (s-HBP) using strain echocardiography. METHODS AND RESULTS: Consecutive patients with permanent His bundle pacing, in whom it was possible to obtain both s-HBP and ns-HBP, were studied in two centers. In each patient, echocardiography was performed sequentially during s-HBP and ns-HBP. Speckle-tracking echocardiography parameters were analyzed: Global longitudinal strain (GLS), the time delay between peak systolic strain in the basal septal and basal lateral segments (BS-BL delay), peak strain dispersion (PSD) and strain delay index. Right ventricle function was assessed using tricuspid annular plane systolic excursion (TAPSE) and tissue Doppler velocity of the lateral tricuspid annulus (S'). A total of 69 patients (age: 75.6 ± 10.5 years; males: 75%) were enrolled. There were no differences in LV ejection fraction and GLS between s-HBP and ns-HBP modes: 59% versus 60%, and -15.6% versus -15.7%, respectively; as well as no difference in BS-BL delay and strain delay index. The PSD value was higher in the ns-HBP group than in the s-HBP group with the most pronounced difference in the basal LV segments. No differences in right ventricular function parameters (TAPSE and S') were found. CONCLUSION: The ns-HBP and s-HBP modes seem comparable regarding ventricular function. The dyssynchrony parameters were significantly higher during ns-HBP, however, the difference seems modest and clarification of its impact on LV function requires a larger long-term study.


Asunto(s)
Fascículo Atrioventricular , Estimulación Cardíaca Artificial , Anciano , Fascículo Atrioventricular/diagnóstico por imagen , Ecocardiografía , Humanos , Masculino , Volumen Sistólico , Función Ventricular Derecha
4.
Antimicrob Agents Chemother ; 64(11)2020 10 20.
Artículo en Inglés | MEDLINE | ID: mdl-32816732

RESUMEN

Vga(A) protein variants confer different levels of resistance to lincosamides, streptogramin A, and pleuromutilins (LSAP) by displacing antibiotics from the ribosome. Here, we show that expression of vga(A) variants from Staphylococcus haemolyticus is regulated by cis-regulatory RNA in response to the LSAP antibiotics by the mechanism of ribosome-mediated attenuation. The specificity of induction depends on Vga(A)-mediated resistance rather than on the sequence of the riboregulator. Fine tuning between Vga(A) activity and its expression in response to the antibiotics may contribute to the selection of more potent Vga(A) variants because newly acquired mutation can be immediately phenotypically manifested.


Asunto(s)
Farmacorresistencia Bacteriana Múltiple , Estreptogramina A , Antibacterianos/farmacología , Proteínas Bacterianas/genética , Lincosamidas , Macrólidos , Ribosomas/genética
5.
J Cardiovasc Electrophysiol ; 31(1): 300-307, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31788894

RESUMEN

INTRODUCTION: The present study introduces a new ultra-high-frequency 14-lead electrocardiogram technique (UHF-ECG) for mapping ventricular depolarization patterns and calculation of novel dyssynchrony parameters that may improve the selection of patients and application of cardiac resynchronization therapy (CRT). METHODS: Components of the ECG in sixteen frequency bands within the 150 to 1000 Hz range were used to create ventricular depolarization maps. The maximum time difference between the UHF QRS complex centers of mass of leads V1 to V8 was defined as ventricular electrical dyssynchrony (e-DYS), and the duration at 50% of peak voltage amplitude in each lead was defined as the duration of local depolarization (Vd). Proof of principle measurements was performed in seven patients with left (left bundle branch block) and four patients with right bundle branch block (right bundle branch block) before and during CRT using biventricular and His-bundle pacing. RESULTS: The acquired activation maps reflect the activation sequence under the tested conditions. e-DYS decreased considerably more than QRS duration, during both biventricular pacing (-50% vs -8%) and His-bundle pacing (-77% vs -13%). While biventricular pacing slightly increased Vd, His-bundle pacing reduced Vd significantly (+11% vs -36%), indicating the contribution of the fast conduction system. Optimization of biventricular pacing by adjusting VV-interval showed a decrease of e-DYS from 102 to 36 ms with only a small Vd increase and QRS duration decrease. CONCLUSIONS: The UHF-ECG technique provides novel information about electrical activation of the ventricles from a standard ECG electrode setup, potentially improving the selection of patients for CRT and application of CRT.


Asunto(s)
Fascículo Atrioventricular/fisiopatología , Bloqueo de Rama/terapia , Terapia de Resincronización Cardíaca , Electrocardiografía , Insuficiencia Cardíaca/terapia , Frecuencia Cardíaca , Potenciales de Acción , Anciano , Anciano de 80 o más Años , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/fisiopatología , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Humanos , Masculino , Valor Predictivo de las Pruebas , Prueba de Estudio Conceptual , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda , Función Ventricular Derecha
6.
Eur Heart J Suppl ; 22(Suppl F): F14-F22, 2020 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-32694949

RESUMEN

The location of the pacemaker lead is based on the shape of the lead on fluoroscopy only, typically in the left and right anterior oblique positions. However, these fluoroscopy criteria are insufficient and many leads apparently considered to be in septum are in fact anchored in anterior wall. Periprocedural ECG could determine the correct lead location. The aim of the current analysis is to characterize ECG criteria associated with a correct position of the right ventricular (RV) lead in the mid-septum. Patients with indications for a pacemaker had the RV lead implanted in the apex (Group A) or mid-septum using the standard fluoroscopic criteria. The exact position of the RV lead was verified using computed tomography. Based on the findings, the mid-septal group was divided into two subgroups: (i) true septum, i.e. lead was found in the mid-septum, and (ii) false septum, i.e. lead was in the adjacent areas (anterior wall, anteroseptal groove). Paced ECGs were acquired from all patients and multiple criteria were analysed. Paced ECGs from 106 patients were analysed (27 in A, 36 in true septum, and 43 in false septum group). Group A had a significantly wider QRS, more left-deviated axis and later transition zone compared with the true septum and false septum groups. There were no differences in presence of q in lead I, or notching in inferior or lateral leads between the three groups. QRS patterns of true septum and false septum groups were similar with only one exception of the transition zone. In the multivariate model, the only ECG parameters associated with correct lead placement in the septum was an earlier transition zone (odds ratio (OR) 2.53, P = 0.001). ECGs can be easily used to differentiate apical pacing from septal or septum-close pacing. The only ECG characteristic that could help to identify true septum lead position was the transition zone in the precordial leads. ClinicalTrials.gov identifier: NCT02412176.

8.
JACC Clin Electrophysiol ; 10(7 Pt 2): 1660-1671, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38852101

RESUMEN

BACKGROUND: Hemolysis-related renal failure has been described after pulmonary vein isolation (PVI) with pulsed-field ablation (PFA). OBJECTIVES: This study sought to compare the potential for hemolysis during PVI with PFA vs radiofrequency ablation (RFA). METHODS: In consecutive patients, PVI was performed with PFA or RFA. Blood samples were drawn at baseline, immediately postablation, and 24 hours postablation. Using flow cytometry, the concentration of red blood cell microparticles (RBCµ) (fragments of damaged erythrocytes) in blood was assessed. Lactate dehydrogenase (LDH), haptoglobin, and indirect bilirubin were measured at baseline and 24 hours. RESULTS: Seventy patients (age: 64.7 ± 10.2 years; 47% women; 36 [51.4%] paroxysmal atrial fibrillation) were enrolled: 47 patients were in the PFA group (22 PVI-only and 36.4 ± 5.5 PFA applications; 25 PVI-plus, 67.3 ± 12.4 pulsed field energy applications), and 23 patients underwent RFA. Compared to baseline, the RBCµ concentration increased ∼12-fold postablation and returned to baseline by 24 hours in the PFA group (median: 70.8 [Q1-Q3: 51.8-102.5] vs 846.6 [Q1-Q3: 639.2-1,215.5] vs 59.3 [Q1-Q3: 42.9-86.5] RBCµ/µL, respectively; P < 0.001); this increase was greater with PVI-plus compared to PVI-only (P = 0.007). There was also a significant, albeit substantially smaller, periprocedural increase in RBCµ with RFA (77.7 [Q1-Q3: 39.2-92.0] vs 149.6 [Q1-Q3: 106.6-180.8] vs 89.0 [Q1-Q3: 61.2-123.4] RBCµ/µL, respectively; P < 0.001). At 24 hours with PFA, the concentration of LDH and indirect bilirubin increased, whereas haptoglobin decreased significantly (all P < 0.001). In contrast, with RFA, there were only smaller changes in LDH and haptoglobin concentrations (P = 0.03) and no change in bilirubin. CONCLUSIONS: PFA was associated with significant periprocedural hemolysis. With a number of 70 PFA lesions, the likelihood of significant renal injury is uncommon.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Hemólisis , Humanos , Femenino , Fibrilación Atrial/cirugía , Masculino , Persona de Mediana Edad , Anciano , Ablación por Catéter/efectos adversos , Venas Pulmonares/cirugía , Ablación por Radiofrecuencia/efectos adversos , Ablación por Radiofrecuencia/métodos , Estudios Prospectivos
9.
JACC Clin Electrophysiol ; 10(3): 463-474, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38085214

RESUMEN

BACKGROUND: Pulsed-field ablation (PFA) represents a new, nonthermal ablation energy for the ablation of atrial fibrillation (AF). Ablation energies producing thermal injury are associated with an inflammatory response, platelet activation, and coagulation activation. OBJECTIVES: This study aimed to compare the systemic response in patients undergoing pulmonary vein isolation (PVI) using pulsed-field and radiofrequency (RF) energy. METHODS: Patients with AF indicated for PVI were enrolled and randomly assigned to undergo PVI using RF (CARTO Smart Touch, Biosense Webster) or pulsed-field (Farapulse, Boston-Scientific) energy. Markers of myocardial damage (troponin I), inflammation (interleukin-6), coagulation (D-dimers, fibrin monomers, von Willebrand antigen and factor activity), and platelet activation (P-selectin, activated GpIIb/IIIa antigen) were measured before the procedure (T1), after trans-septal puncture (T2), after completing the ablation in the left atrium (T3), and 1 day after the procedure (T4). RESULTS: A total of 65 patients were enrolled in the pulsed-field ablation (n = 33) and RF ablation (n = 32) groups. Both groups were similar in baseline characteristics (age 60.5 ± 12.7 years vs 64.0 ± 10.7 years; paroxysmal AF: 60.6% vs 62.5% patients). Procedural and left atrial dwelling times were substantially shorter in the PFA group (55:09 ± 11:57 min vs 151:19 ± 41:25 min; P < 0.001; 36:00 ± 8:05 min vs 115:58 ± 36:49 min; P < 0.001). Peak troponin release was substantially higher in the PFA group (10,102 ng/L [IQR: 8,272-14,207 ng/L] vs 1,006 ng/L [IQR: 603-1,433ng/L]). Both procedures were associated with similar extents (>50%) of platelet and coagulation activation. The proinflammatory response 24 h after the procedure was slightly but nonsignificantly higher in the RF group. CONCLUSIONS: Despite 10 times more myocardial damage, pulsed-field ablation was associated with a similar degree of platelet/coagulation activation, and slightly lower inflammatory response. (The Effect of Pulsed-Field and Radiofrequency Ablation on Platelet, Coagulation and Inflammation; NCT05603637).


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Inflamación , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía
10.
Int J Syst Evol Microbiol ; 63(Pt 1): 377-387, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23087168

RESUMEN

The diversity of green microalgae in subaerial habitats remains largely unexplored and a number of new genus- and species-level lineages have been discovered recently. The traditional green algal genus, Chlorella, which accommodated coccoid unicellular green algal species with globular to oval cells, reproducing entirely by autospores, has been found to be polyphyletic. In this study, we provide a detailed characterization of two strains of microalgae isolated from tree bark in the Mediterranean. These algae share the general Chlorella-like morphology and their 18S rRNA and rbcL gene sequences place them in the Trebouxiophyceae. Strain CAUP H8401 forms an independent trebouxiophycean lineage, together with three previously published 18S rRNA gene environmental sequences of undescribed microalgae, which were retrieved from profoundly different habitats. In contrast, strain CAUP H7902 is related to Kalinella bambusicola in the Watanabea clade of the Trebouxiophyceae on the basis of its 18S rRNA gene sequence. This relationship is also supported by the rbcL gene sequence, acquired from the type strain of K. bambusicola. The investigated strains are described as representatives of a novel species in a new genus, Leptochlorella corticola gen. et sp. nov., and a novel species, Kalinella apyrenoidosa sp. nov., according to the International Code of Nomenclature for Algae, Fungi and Plants.


Asunto(s)
Chlorophyta/clasificación , Cupressus/microbiología , Laurus/microbiología , Filogenia , Corteza de la Planta/microbiología , Chlorophyta/genética , Chlorophyta/ultraestructura , ADN de Algas/genética , Región Mediterránea , Datos de Secuencia Molecular , ARN Ribosómico 16S/genética , ARN Ribosómico 18S/genética , Análisis de Secuencia de ADN , Eslovenia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA