Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 34(1): 82-89, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36321661

RESUMEN

INTRODUCTION: Aim of this study was to evaluate the incidence of ablation-induced endoscopically detected esophageal lesions (EDEL) and gastroparesis in patients undergoing high-power short-duration (HPSD) atrial fibrillation (AF) ablation using different target ablation index (AI) values. METHODS AND RESULTS: Consecutive patients undergoing AF ablation were included. Radiofrequency (RF) ablation was performed using HPSD ablation (50 W, target AI of 320 and 350 (group 1) and 380 (group 2) at posterior wall). Postablation endoscopy was performed in all patients. In total, 233 patients (66.8 ± 10 years; 52% male) were included consecutively (n = 137 patients in group 1 and n = 96 patients in group 2). Mean AI values und RF time at posterior wall was significantly higher and longer in group 2 compared to group 1 patients (413 ± 9 vs. 392 ± 19 AI, p < 0.01; 9.0 ± 0.8 s vs. 7.8 ± 0.7 s, p < 0.01). Esophageal endoscopy revealed esophageal lesions or gastroparesis in 43 of 233 patients (18.5%) in the total cohort (13.1% in group 1 and 26.0% in group 2; p = 0.02). Incidence of EDEL was 8.0% and 13.5% in group 1 and group 2, respectively. According to logistic analysis incidence of EDEL and/or gastroparesis was significantly lower in patients with a higher body mass index and higher in group 2 patients compared to group 1 patients. CONCLUSION: The incidence of EDEL or gastroparesis in patients undergoing HPSD AF ablation was 18.5% in the total cohort. The risk of EDEL and gastroparesis was associated with a higher AI target value of 380 compared to 320 and 350 at posterior wall and was reversely associated with body mass index.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Gastroparesia , Venas Pulmonares , Humanos , Masculino , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Incidencia , Gastroparesia/diagnóstico , Gastroparesia/epidemiología , Gastroparesia/etiología , Esófago/diagnóstico por imagen , Esófago/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Resultado del Tratamiento
2.
Europace ; 25(4): 1379-1391, 2023 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-36881791

RESUMEN

AIMS: Pulmonary vein isolation using radiofrequency ablation is an effective treatment option for patients with symptomatic atrial fibrillation (AF). Application of high power over a short period of time (HPSD) is reported to create more efficient lesions and may prevent collateral thermal oesophageal injury. This study aims to compare efficacy and safety of two different HPSD ablation approaches using different ablation index settings. METHODS AND RESULTS: Consecutive patients undergoing AF ablation with HPSD (50 W; ablation index-guided) using the ThermoCool SmartTouch SF catheter were included. Patients were grouped by ablation protocol: ablation with target ablation index (AI) of 400 on the anterior left atrial wall vs. 300 at the posterior left atrial wall (AI 400/300) or AI 450/350 was performed upon the operator's preference and compared. Peri-procedural parameters and complications were recorded, and incidences of endoscopically detected thermal oesophageal lesions (EDEL) analysed. Recurrence rates after a mean follow-up of 25 ± 7 months and reconnection patterns in patients undergoing redo procedures were investigated. A total of 795 patients (67 ± 10 years; 58% male; 48% paroxysmal AF) underwent a first AF ablation with HPSD (211 in group AI 400/300 and 584 in group 450/350). Median procedure time was 82.9 ± 24.6 min with longer ablation times in patients with target AI 400/300 due to higher intraprocedural reconnection rates, increased box lesions, and additional right atrial isthmus ablations. EDEL rates among target AI 400/300 procedures were significantly lower (3% vs. 7%; P = 0.019). Correspondingly, AI 450/350 was the strongest independent predictor of post-ablation EDEL (OR 4.799, CI 1.427-16.138, P = 0.011). Twelve-month (76% vs. 76%; P = 0.892) and long-term ablation single procedure success (68% vs. 71%; log-rank P = 0.452) after a mean of 25 ± 7 months were comparable among both target AI groups; however, long-term success was significantly higher for paroxysmal AF compared to persistent AF (12 months: 80% vs. 72%; P = 0.010; end of follow-up: 76% vs. 65%; log-rank P = 0.001). One hundred three patients (16%) underwent a redo procedure during follow-up documented comparable pulmonary vein (PV) reconnection among groups. Multivariate predictors of AF recurrence were age, left atrium (LA) size, persistent AF, and extra-PV ablation targets. CONCLUSION: High-power short-duration AF ablation with target AI of 400 for non-posterior wall and 300 for posterior wall lesions resulted in comparable long-term results compared to higher AI (450/350) ablations with significantly lower risk for thermal oesophageal lesions. Older age, larger LA size, persistent AF, and extra-PV ablation targets were identified in a multivariate analysis as independent risk factors for recurrences of atrial arrhythmias.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Fibrilación Atrial/etiología , Estudios de Seguimiento , Resultado del Tratamiento , Esófago/cirugía , Inteligencia Artificial , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Recurrencia
3.
J Cardiovasc Electrophysiol ; 33(7): 1425-1434, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35441414

RESUMEN

INTRODUCTION: Data about atrial fibrillation (AF) ablation using high-power short duration (HPSD) radiofrequency ablation in the elderly population is still scarce. The aim of our study was to investigate the efficacy and safety of HPSD ablation in patients over 75 years compared to younger patients. METHODS: Consecutive patients older than 75 years with paroxysmal or persistent AF undergoing a first-time AF ablation using 50 W HPSD ablation approach were analyzed in this retrospective observational analysis and compared to a control group <75 years. Short-term endpoints included intraprocedural reconnection of at least one pulmonary vein (PV) and intrahospital and AF recurrence during 3 months blanking period, as well as a long-term endpoint of freedom from atrial arrhythmias of antiarrhythmic drugs after 12 months. RESULTS: A total of 540 patients underwent a first AF ablation with HPSD (66 ± 10 years; 58% male; 47% paroxysmal AF). Mean age was 78 ± 2.4 and 63 ± 6.3 years (p < .001), respectively. Elderly patients were significantly more often women (p < .001). The procedure, fluoroscopy, and ablation were comparable. Elderly patients revealed significantly more often extra-PV low-voltage areas requiring additional left atrial ablations (p < .001). Overall complication rates were low; however, elderly patients revealed higher major complication rates mainly due to unmasking sick sinus syndrome (p = .003). Freedom from arrhythmia recurrences was comparable (68% vs. 76%, log-rank p = .087). Only in the subgroup of paroxysmal AF, AF recurrences were more common after 12 months (69% vs. 82%; log-rank p = .040; hazard ratio: 1.462, p = .044) in the elderly patients. In multivariable Cox regression analysis of the whole cohort persistent AF, female gender, diabetes mellitus and presence of left atrium low-voltage areas, but not age >75 years were associated with AF recurrences. CONCLUSION: HPSD AF ablation of patients >75 years in experienced centers is safe and effective. Therefore, age alone should not be the reason to withhold AF ablation from vital elderly patients due to only a slightly worse outcome and safety profile. In paroxysmal AF, elderly patients have more recurrences compared to the younger control group.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/etiología , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Humanos , Masculino , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
4.
J Cardiovasc Electrophysiol ; 33(5): 920-927, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35233883

RESUMEN

INTRODUCTION: High power short duration (HPSD) ablation proved to be an effective and safe ablation technique for atrial fibrillation (AF). In former case series, a significant amount of postablation coagulation at the catheter tip as well as silent cerebral lesions (SCL) in postprocedural cerebral magnetic resonance (cMRI) have been identified in patients undergoing de-novo AF ablations with very high power 90 W short duration (vHPvSD) ablations using the QDot ablation catheter in combination with a novel RF generator (nGEN, Biosense Webster). Therefore, the RF generator software has been recently modified. METHODS AND RESULTS: Consecutive patients undergoing a first AF ablation including pulmonary vein isolation (PVI) with vHPvSD (90 W, with a predefined ablation time of 3 s at posterior left atrium (LA) wall sites and 4 s at other ablation sites) using the QDOT Micro ablation catheter (Biosense Webster) in conjunction with the technically modified nGEN RF generator (software V1c; Biosense Webster) were included. Procedural characteristics including first-pass isolation per pulmonary vein (PV) pair and early reconnection location within the 30-min waiting period were recorded. In all patients postablation endoscopy to document any thermal esophageal injury (EDEL) and in eligible patients a cMRI to detect silent cerebral events (SCEs)/lesions were performed. All acute procedure-related complications were recorded during the time until hospital discharge. Furthermore, short-term and midterm success after 3 and 6-12 months of follow-up was investigated. In total, 34 consecutive patients (67 ± 9 years; 62% male; 68% paroxysmal AF) were included. First-pass isolation of all PVs was achieved in 6/34 (18%) patients. First-pass isolation was seen in 37/68 (54%) of PV pairs. Early reconnection occurred in 11 (32%) patients (including reconnections at posterior LA wall sites n = 6 and at nonposterior sites n = 5). No patient had an EDEL (0%). In 6/23 (26%) patients undergoing postablation cerebral MRI SCEs were identified. In six patients, coagulation on the catheter tip was detected at the end of the procedure. No further peri- or postprocedural complications were detected. Early AF recurrence before discharge was seen in 1/34 (3%) of the patients included in this study. Within 3 months 10/34 (29%) revealed AF recurrence during blanking period. After a mean follow-up of 7 months, 31/34 (88%) patients revealed sinus rhythm. CONCLUSION: AF ablation using 90 W vHPvSD with a specialized ablation catheter in conjunction with a recently modified RF generator was associated with no EDEL in the whole study cohort and 26% SCEs in a subgroup of patients undergoing acute postablation cerebral MRI. Accordingly, to our previously published results, a relevant number of catheter tip coagulations was identified in this patient cohort even after modifications of the RF generator. The vHPvSD ablation technique using the present and the previous generator seems to be associated with a very low rate of esophageal injury. However, the recently revised generator software also produced a relevant number of catheter tip coagulum formation and SCEs.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Esófago , Femenino , Humanos , Masculino , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 33(12): 2504-2513, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36124396

RESUMEN

BACKGROUND: This study sought to evaluate the short and midterm efficacy and safety of the novel very high power very short duration (vHPvSD) 90 W approach compared to HPSD 50 W for atrial fibrillation (AF) ablation as well as reconnection patterns of 90 W ablations. METHODS AND RESULTS: Consecutive patients undergoing first AF ablation with vHPvSD (90 W; predefined ablation time of 3 s for posterior wall ablation and 4 s for anterior wall ablation) were compared to patients using HPSD (50 W; ablation index-guided; AI 350 for posterior wall ablation, AI 450 for anterior wall ablation) retrospectively. A total of 84 patients (67.1 ± 9.8 years; 58% male; 47% paroxysmal AF) were included (42 with 90 W, 42 with 50 W) out of a propensity score-matched cohort. 90 W ablations revealed shorter ablation times (10.5 ± 6.7 min vs. 17.4 ± 9.9 min; p = .001). No major complication occurred. 90 W ablations revealed lower first pass PVI rates (40% vs. 62%; p = .049) and higher AF recurrences during blanking period (38% vs. 12%; p = .007). After 12 months, both ablation approaches revealed comparable midterm outcomes (62% vs. 70%; log-rank p = .452). In a multivariable Cox regression model, persistent AF (hazard ratio [HR]: 1.442, 95% confidence interval [CI]: 1.035-2.010, p = .031) and increased procedural duration (HR: 1.011, 95% CI: 1.005-1.017, p = .001) were identified as independent predictors of AF recurrence during follow-up. CONCLUSIONS: AF ablation using 90 W vHPvSD reveals a similar safety profile compared to 50 W ablation with shorter ablation times. However, vHPvSD ablation was associated with lower rates of first-pass isolations and increased AF recurrences during the blanking period. After 12 months, 90 W revealed comparable efficacy results to 50 W ablations in a nonrandomized, propensity-matched comparison.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Estudios Retrospectivos , Recurrencia , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos
6.
Europace ; 24(6): 928-937, 2022 07 15.
Artículo en Inglés | MEDLINE | ID: mdl-35134155

RESUMEN

AIMS: Pulmonary vein isolation (PVI) using radiofrequency (RF) ablation is an effective treatment option for patients with atrial fibrillation (AF). This study aims to investigate the safety of high-power short duration (HPSD) with emphasis on oesophageal lesions after PVI. METHODS AND RESULTS: Consecutive patients undergoing AF ablation with HPSD (50 W; ablation index (AI)-guided; target AI 350 for posterior wall ablation, AI 450 for anterior wall ablation) using the ThermoCool SmartTouch SF catheter were included. Patients underwent post-ablation oesophageal endoscopy to detect and categorize thermal oesophageal injury (EDEL). Occurrence and risk factors of oesophageal lesions and perforating complications were analysed. A total of 1033 patients underwent AF ablation with HPSD. Of them, 953 patients (67.6 ± 9.6 years; 58% male; 43% paroxysmal AF; 68% first PVI) underwent post-procedural oesophageal endoscopy and were included in further analyses. Median procedure time was 82.8 ± 24.4 min with ablation times of 16.1 ± 9.2 min. Thermal oesophageal injury was detected in 58 patients (6%) (n = 29 Category 1 erosion, n = 29 Category 2 ulcerous). One patient developed oesophageal perforation (redo, 4th AF ablation). No patient died. Using multivariable regression models, increased total ablation time [odds ratio (OR) 1.029, P = 0.010] and history of stroke (OR 2.619, P = 0.033) were associated with increased incidence of EDEL after AF ablation, whereas increased body mass index was protective (OR 0.980, P = 0.022). CONCLUSION: Thermal oesophageal lesions occur in 6% of HPSD AF ablations. The risk for development of perforating complications seems to be low. Incidence of atrio-oesophageal fistula (0.1%) is comparable to other reported series about RF ablation approaches.


Asunto(s)
Fibrilación Atrial , Quemaduras , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Quemaduras/epidemiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Esofagoscopía/efectos adversos , Esófago/lesiones , Femenino , Humanos , Masculino , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
7.
Artículo en Inglés | MEDLINE | ID: mdl-34655759

RESUMEN

INTRODUCTION: Aim of this study was to evaluate efficacy and safety of ventricular tachycardia (VT) catheter ablation in patients with structural heart disease (SHD) in relation to the presence of an intramural septal substrate. METHODS: Consecutive patients undergoing VT ablation between January 2019 and October 2020 were included. All patients were stratified based on the presence of relevant septal substrate and freedom from VT recurrences were analyzed. RESULTS: In total, 199 consecutive patients (64.2 ± 13.0 years; 89% male; 55% ischemic cardiomyopathy (ICM)) undergoing VT ablation were included. 129/199 patients (65%) showed significant septal substrate (55/90 patients (61%) with non-ischemic cardiomyopathy (NICM) compared to 74/109 patients (68%) with ICM; p = 0.37). Acute procedural success with elimination of all inducible VTs was achieved in 66/70 patients (94%) without and in 103/129 patients (80%) with a septal substrate (p = 0.007). In the cohort including patients with a clinical FU, 15/60 patients (25%) without a septal substrate and 48/123 patients (39%) with a septal substrate experienced VT recurrence during a FU of 8.1 ± 5.9 months (p = 0.069). CONCLUSION: Presence of septal VT substrate in patients with a structural heart disease or coronary artery disease is common. Acute success of VT catheter ablation was significantly higher and mid-term success tended to be higher in patients without a septal substrate.

8.
J Interv Cardiol ; 2021: 8843935, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33536855

RESUMEN

BACKGROUND: Although scoring systems are widely used to predict outcomes in postcardiac arrest cardiogenic shock (CS) after out-of-hospital cardiac arrest (OHCA) complicating acute myocardial infarction (AMI), data concerning the accuracy of these scores to predict mortality of patients treated with Impella in this setting are lacking. Thus, we aimed to evaluate as well as to compare the prognostic accuracy of acute physiology and chronic health II (APACHE II), simplified acute physiology score II (SAPS II), sepsis-related organ failure assessment (SOFA), the intra-aortic balloon pump (IABP), CardShock, the prediction of cardiogenic shock outcome for AMI patients salvaged by VA-ECMO (ENCOURAGE), and the survival after venoarterial extracorporeal membrane oxygenation (SAVE) score in patients with OHCA refractory CS due to an AMI treated with Impella 2.5 or CP. METHODS: Retrospective study of 65 consecutive Impella 2.5 and 32 CP patients treated in our cardiac arrest center from September 2015 until June 2020. RESULTS: Overall survival to discharge was 44.3%. The expected mortality according to scores was SOFA 70%, SAPS II 90%, IABP shock 55%, CardShock 80%, APACHE II 85%, ENCOURAGE 50%, and SAVE score 70% in the 2.5 group; SOFA 70%, SAPS II 85%, IABP shock 55%, CardShock 80%, APACHE II 85%, ENCOURAGE 75%, and SAVE score 70% in the CP group. The ENCOURAGE score was the most effective predictive model of mortality outcome presenting a moderate area under the curve (AUC) of 0.79, followed by the CardShock, APACHE II, IABP, and SAPS score. These derived an AUC between 0.71 and 0.78. The SOFA and the SAVE scores failed to predict the outcome in this particular setting of refractory CS after OHCA due to an AMI. CONCLUSION: The available intensive care and newly developed CS scores offered only a moderate prognostic accuracy for outcomes in OHCA patients with refractory CS due to an AMI treated with Impella. A new score is needed in order to guide the therapy in these patients.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Paro Cardíaco Extrahospitalario , Medición de Riesgo/métodos , Choque Cardiogénico , Anciano , Cuidados Críticos/métodos , Oxigenación por Membrana Extracorpórea/métodos , Oxigenación por Membrana Extracorpórea/mortalidad , Femenino , Humanos , Contrapulsador Intraaórtico/métodos , Contrapulsador Intraaórtico/mortalidad , Masculino , Persona de Mediana Edad , Puntuaciones en la Disfunción de Órganos , Paro Cardíaco Extrahospitalario/complicaciones , Paro Cardíaco Extrahospitalario/terapia , Pronóstico , Estudios Retrospectivos , Choque Cardiogénico/etiología , Choque Cardiogénico/mortalidad , Choque Cardiogénico/terapia , Análisis de Supervivencia
9.
Int J Mol Sci ; 23(1)2021 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-35008777

RESUMEN

Oncostatin M (OSM) and leukemia inhibitory factor (LIF) signaling protects the heart after myocardial infarction (MI). In mice, oncostatin M receptor (OSMR) and leukemia inhibitory factor receptor (LIFR) are selectively activated by the respective cognate ligands while OSM activates both the OSMR and LIFR in humans, which prevents efficient translation of mouse data into potential clinical applications. We used an engineered human-like OSM (hlOSM) protein, capable to signal via both OSMR and LIFR, to evaluate beneficial effects on cardiomyocytes and hearts after MI in comparison to selective stimulation of either LIFR or OSMR. Cell viability assays, transcriptome and immunoblot analysis revealed increased survival of hypoxic cardiomyocytes by mLIF, mOSM and hlOSM stimulation, associated with increased activation of STAT3. Kinetic expression profiling of infarcted hearts further specified a transient increase of OSM and LIF during the early inflammatory phase of cardiac remodeling. A post-infarction delivery of hlOSM but not mOSM or mLIF within this time period combined with cardiac magnetic resonance imaging-based strain analysis uncovered a global cardioprotective effect on infarcted hearts. Our data conclusively suggest that a simultaneous and rapid activation of OSMR and LIFR after MI offers a therapeutic opportunity to preserve functional and structural integrity of the infarcted heart.


Asunto(s)
Cardiotónicos/metabolismo , Infarto del Miocardio/prevención & control , Oncostatina M/metabolismo , Receptores OSM-LIF/metabolismo , Animales , Hipoxia de la Célula/genética , Supervivencia Celular , Células Cultivadas , Humanos , Cinética , Factor Inhibidor de Leucemia/metabolismo , Ratones , Contracción Miocárdica , Infarto del Miocardio/genética , Miocitos Cardíacos/metabolismo , Ingeniería de Proteínas , Proteínas Proto-Oncogénicas c-myc/metabolismo , Receptores de Oncostatina M/metabolismo , Factor de Transcripción STAT3/metabolismo , Factor de Transcripción STAT5/metabolismo , Transducción de Señal , Especificidad de la Especie , Transcriptoma/genética
10.
J Interv Cardiol ; 2020: 6542028, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32934608

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is a highly prevalent comorbidity in patients with severe mitral valve regurgitation (MR). Recent studies show a deleterious outcome of patients with concomitant AF after transcatheter mitral valve repair (TMVR). This underlines the essential need for additional strategies that ameliorate the prognosis of these patients. Fundamental data on AF characteristics and treatment regimes in this special cohort of patients are lacking. METHODS: We retrospectively analyzed the data of 542 consecutive patients with severe MR undergoing TMVR in three tertiary heart centers with special focus on AF type and underlying treatment strategies. RESULTS: The prevalence of concomitant AF was 73.3%, and AF did not affect the procedural success or the incidence of major adverse cardiac and cerebrovascular events. The patients with AF were more frequently >75 years, had more tricuspid regurgitation, and less coronary artery disease than non-AF patients. The distribution of AF types was 32% paroxysmal AF, 27% persistent AF, and 41% permanent AF. Except for a higher degree in severe tricuspid regurgitation and a higher likelihood of male sex, no substantial differences were observed while comparing permanent and nonpermanent AF patients. The predominant treatment regime was rate control (57%), with only beta blockers (BB) in the majority of persistent and permanent AF patients, while additional digitalis or a pacemaker was used infrequently. Rhythm control was mainly achieved with BB alone in paroxysmal AF patients and with additional antiarrhythmic drugs in the majority of persistent AF patients. Interventional rhythm control therapy was performed in 2.5% and 30.9% of paroxysmal and persistent AF patients, respectively. The guideline-adherent use of oral anticoagulants was comparable and high in both groups (91.9% in nonpermanent vs. 90.1% in permanent AF). CONCLUSION: This is the first study to provide necessary information for the understanding of the current clinical practice in dealing with TMVR patients. Since evidence suggests that AF is not a benign concomitant disease, further investigations are needed to assess the prognostic impact of these different AF treatment strategies.


Asunto(s)
Antiarrítmicos , Anticoagulantes , Fibrilación Atrial , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral , Anciano , Antiarrítmicos/uso terapéutico , Anticoagulantes/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/epidemiología , Cateterismo Cardíaco/métodos , Comorbilidad , Femenino , Humanos , Masculino , Administración del Tratamiento Farmacológico , Anuloplastia de la Válvula Mitral/métodos , Insuficiencia de la Válvula Mitral/epidemiología , Insuficiencia de la Válvula Mitral/cirugía , Pronóstico , Factores de Riesgo , Resultado del Tratamiento
11.
J Clin Med ; 13(2)2024 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-38276082

RESUMEN

Focal pulsed field ablation (PFA) is a novel technique for treating cardiac arrhythmias. It has demonstrated positive results in initial studies and has a good safety profile. In recent studies, PFA was often utilized for first-time pulmonary vein isolation (PVI) and was performed under general anesthesia. In our study, we assessed the feasibility, safety, acute procedural efficacy, and efficiency of focal PFA under deep sedation in patients, 80% of whom had undergone at least one left atrial ablation previously. We treated 30 patients (71 ± 7, 46% male) using the CENTAURI system for various atrial arrhythmias, including atrial fibrillation, typical and atypical atrial flutter, and focal atrial tachycardia. The average procedure and fluoroscopy times were 122 ± 43 min and 9 ± 7 min, respectively. A total of 83.33% of patients received additional line ablations beyond PVI, specifically targeting the posterior box and anterior mitral line. All ablations were successfully performed in deep sedation with only one major and one minor complication observed. The major complication was a vasospasm of the right coronary artery during ablation of the cavotricuspid isthmus, which was treated successfully with intracoronary nitroglycerin. All patients could be discharged in sinus rhythm. Moreover, adenosine appears effective in identifying dormant conduction in some patients after focal PFA. In conclusion, focal PFA is an effective approach for complex left atrial ablations under deep sedation, offering both high efficacy and efficiency with a reliable safety profile. Studies on long-term outcomes are needed.

12.
Clin Case Rep ; 11(6): e7525, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37327138

RESUMEN

Key Clinical Message: Nonspecific symptoms such as pleuritic or pericardial chest pain in cardiovascular implantable electronic devices patients, even with unremarkable ECG or device parameters, should always raise suspicion of electrode perforation, regardless of how long ago the implantation was performed. Abstract: We report the successful percutaneous management of a 77-year-old woman who had a dual-chamber pacemaker implanted more than 1 year ago and presented with pericarditis pain and compensated pericardial hemorrhagic tamponade. The symptoms were due to very late acute perforation of the atrial lead. This report is intended to raise awareness of procedure-related complications in the large group of cardiovascular implantable electronic device patients. Pleuritic or pericardial pain in these patients should raise suspicion of electrode perforation, as the risk of perforation is not restricted to the period immediately after implantation and a lifelong risk cannot apparently be excluded.

13.
J Clin Med ; 12(23)2023 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-38068282

RESUMEN

BACKGROUND: mitral regurgitation (mr) is the most common valvular heart disease (vhd) in the elderly and tends to be more prevalent in women. while relevant sex differences in outcomes are evident in surgically treated collectives, there are very limited and conflicting sex-specific data for the growing cohort of patients undergoing transcatheter edge-to-edge repair (teer). OBJECTIVE: to investigate whether sex impacts procedural safety and efficacy, and in-hospital- and long-term outcomes, after teer for mr. METHODS: in a multicenter observational cohort study, patients who underwent teer were stratified by sex and relevant outcome measures, and analyzed using multivariable cox regression and propensity score matching (psm). RESULTS: a total of 821 patients were analyzed, of whom 37.4% (307/821) were female. compared to male patients, females were significantly older (77 ± 8.5 vs. 80.4 ± 6.7 years, p = 0.03), and had less coronary artery disease (cad, 67.7% vs. 53.1%, p < 0.0001) and a higher proportion of preserved left ventricular function (lvef > 50%, 32.5% vs. 50.5%, p > 0.0001). safety and efficacy of the teer procedure and in-hospital mortality did not differ between the sexes. after psm, women showed significantly better survival 3 years after teer compared to men (60.7% vs. 54.2%, p = 0.04) and a lower risk of all-cause death according to multiple cox regression (hr 0.8, 95% ci 0.6-0.9, p = 0.02). after sex-specific stratification for concomitant atrial fibrillation (af), the most common comorbidity in the present collective, women with af experience significantly worse adjusted survival compared to women without af (53.9% vs. 75.1%, p = 0.042) three years after teer and lose the survival advantage over men. CONCLUSIONS: female patients are older and less comorbid than males undergoing TEER. The TEER procedure is equally safe and effective in both sexes. While in-hospital mortality did not differ, female patients experienced a significantly better adjusted long-term survival compared to male patients. Concomitant AF offsets the prognostic advantage of females over males and, in contrast to males, significantly impairs long-term survival in women undergoing TEER. Further research is warranted to elucidate underlying causes for the observed sex disparities and to develop sex-tailored treatment recommendations.

14.
J Clin Med ; 12(22)2023 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-38002789

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) is an effective treatment option for patients with symptomatic atrial fibrillation (AF). However, the electrical recovery of pulmonary veins (PVs) is the main trigger for AF recurrences. This study investigates the characteristics of patients admitted for redo AF ablation, the PV reconnection rates depending on previous ablation modalities and the impact of different ablation strategies for redo procedures. METHODS: Consecutive patients undergoing first redo AF ablation were included. Patients were grouped according to the electrical recovery of at least one PV. The impacts of the technique for first AF ablation on PV reconnection rates and patients with and without PV reconnection were compared. Different ablation strategies for redo procedures were compared and its recurrence rates after a mean follow-up of 25 ± 20 months were investigated. RESULTS: A total of 389 patients (68 ± 10 years; 57% male; 39% paroxysmal AF) underwent a first redo. The median time between the first and redo procedure was 40 ± 39 months. Radiofrequency was used in 278 patients, cryoballoon was used in 85 patients and surgical AF ablation was performed on 26 patients. In total, 325 patients (84%) had at least one PV reconnected, and the mean number of reconnected PVs was 2.0 ± 1.3, with significant differences between ablation approaches (p for all = 0.002); this was mainly due to differences in the left inferior PV and right superior PV reconnections. The presence of PV reconnection during redo was not associated with better long-term success compared to completely isolated PVs (67% vs. 67%; log-rank p = 0.997). Overall, the different ablation strategies for redos were comparable regarding AF recurrences during follow-up (p = 0.079), with the ablation approach having no impact in the case of left atrial low voltage or without. CONCLUSIONS: PV reconnections after initial successful PVI are common among all techniques of AF ablation. Long-term rhythm control off antiarrhythmic drugs was possible in 2/3 of all patients after the redo procedure; however, different ablation strategies with extra-PV trigger ablation did not improve long-term success. Patients with recurrent AF after PVI constitute a challenging group of patients.

15.
Front Cardiovasc Med ; 10: 1229651, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37645518

RESUMEN

Background: Atrial fibrillation (AF) is the most common concomitant disease in patients undergoing transcatheter edge-to-edge repair (TEER) for mitral regurgitation (MR) and detrimentally affects their outcome. While there is increasing evidence for prognostic improvement and safety of catheter ablation (CA) of AF in the overall cohort of heart failure patients, corresponding data in TEER patients are lacking. Objectives: To investigate the impact of treatment regimens for concomitant AF on survival of TEER patients. Methods: In a multicenter observational cohort study consecutive patients successfully undergoing TEER were analyzed and survival of patients receiving CA of concomitant AF was compared with that of patients on pharmacological AF treatment and with that of patients without a history of AF, using propensity score matching (PSM). Results: A total of 821 patients were analyzed. Of these, 608 (74.1%) had concomitant AF, of whom 48 patients received CA. Patients with CA in AF showed significantly higher 3-year-survival after TEER compared to PSM-patients on pharmacological AF treatment (75.5% [36/48] vs. 49.4% [166/336], p = 0.009). The 3-year-survival after TEER of patients with concomitant AF treated with CA was not significantly different from PSM-patients without AF (75.5% [36/48] vs. 68.3% [98/144], p = 0.36). Conclusions: CA of AF is superior to pharmacotherapy as it significantly improves the survival of TEER patients in a PSM analysis. CA even offsets the prognostic disadvantage of coexisting AF in TEER patients. Given the growing evidence of prognostic benefits in the overall cohort of HF patients, our data point out the importance of treating concomitant AF and support CA as an essential part of a holistic management of TEER patients.

16.
Front Genet ; 14: 1213829, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37564874

RESUMEN

Next-generation sequencing has revolutionized the field of microbiology research and greatly expanded our knowledge of complex bacterial communities. Nanopore sequencing provides distinct advantages, combining cost-effectiveness, ease of use, high throughput, and high taxonomic resolution through its ability to process long amplicons, such as the entire 16s rRNA genome. We examine the performance of the conventional 27F primer (27F-I) included in the 16S Barcoding Kit distributed by Oxford Nanopore Technologies (ONT) and that of a more degenerate 27F primer (27F-II) in the context of highly complex bacterial communities in 73 human fecal samples. The results show striking differences in both taxonomic diversity and relative abundance of a substantial number of taxa between the two primer sets. Primer 27F-I reveals a significantly lower biodiversity and, for example, at the taxonomic level of the phyla, a dominance of Firmicutes and Proteobacteria as determined by relative abundances, as well as an unusually high ratio of Firmicutes/Bacteriodetes when compared to the more degenerate primer set (27F-II). Considering the findings in the context of the gut microbiomes common in Western industrial societies, as reported in the American Gut Project, the more degenerate primer set (27F-II) reflects the composition and diversity of the fecal microbiome significantly better than the 27F-I primer. This study provides a fundamentally relevant comparative analysis of the in situ performance of two primer sets designed for sequencing of the entire 16s rRNA genome and suggests that the more degenerate primer set (27F-II) should be preferred for nanopore sequencing-based analyses of the human fecal microbiome.

17.
J Clin Med ; 12(7)2023 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-37048813

RESUMEN

BACKGROUND: Electrical storm (ES) represents a serious heart rhythm disorder. This study investigates the impact of ES on acute ablation success and long-term outcomes after VT ablation compared to non-ES patients. METHODS: In this large single-centre study, patients presenting with ES and undergoing VT ablation from June 2018 to April 2021 were compared to patients undergoing VT ablation due to ventricular tachyarrhythmias but without ES. The primary prognostic outcome was VT recurrence, and secondary endpoints were rehospitalization rates and cardiovascular mortality, all after a median follow-up of 22 months. RESULTS: A total of 311 patients underwent a first VT ablation due to ventricular tachyarrhythmias and were included (63 ± 14 years; 86% male). Of these, 108 presented with ES. In the ES cohort, dilated cardiomyopathy as underlying heart disease was significantly higher (p = 0.008). Major complications were equal across both groups (all p > 0.05). Ablation of the clinical VT was achieved in 94% of all patients (p > 0.05). Noninducibility of any VT was achieved in 91% without ES and in 76% with ES (p = 0.001). Patients with ES revealed increased VT recurrence rates during follow-up (65% vs. 40%; log rank p = 0.001; HR 1.841, 95% CI 1.289-2.628; p = 0.001). Furthermore, ES patients suffered from increased rehospitalization rates (73% vs. 48%; log rank p = 0.001; HR 1.948, 95% CI 1.415-2.682; p = 0.001) and cardiovascular mortality (18% vs. 9%; log rank p = 0.045; HR 1.948, 95% CI 1.004-3.780; p = 0.049). After multivariable adjustment, ES was a strong independent predictor of VT recurrence and rehospitalization rates, but not for mortality. In a propensity score-matched cohort, patients with ES still had a higher risk of VT recurrences and rehospitalizations compared to non-ES patients. CONCLUSIONS: VT ablation in patients with ES is challenging and these patients reveal the highest risk for recurrent VTs, rehospitalization and cardiovascular mortality. These patients need close follow-ups and optimal guideline-directed therapy.

18.
JACC Clin Electrophysiol ; 9(6): 790-804, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36951814

RESUMEN

BACKGROUND: Data about ventricular tachycardia (VT) ablation in patients with electrical storm (ES) is limited. OBJECTIVES: This study sought to compare the prognostic outcome of patients undergoing VT ablation after ES with and without a septal substrate. METHODS: In this large single-center study, consecutive patients presenting with ES and undergoing VT ablation from June 2018 to April 2021 were included. Patients with septal substrate were compared with patients without septal substrate regarding endpoints of cardiovascular mortality, VT recurrences, recurrences of the clinical VT, and rehospitalization rates. RESULTS: A total of 107 patients undergoing a first VT ablation because of electrical storm (ES) were included (age 65 ± 13 years, 86% male, 45% ischemic cardiomyopathy). Major complications occurred in 11% of all patients with increased postinterventional third-degree atrioventricular blocks among patients with septal substrate (9% vs 0%; P = 0.063). Partial ablation successes were similar (95% with a septal substrate vs 100% without a septal substrate; P = 0.251). Complete ablation success was achieved in 63% with a septal substrate and in 87% without a septal substrate (P = 0.004). After a median 22 months of follow-up, patients with septal substrate died significantly more often from cardiovascular causes (26% vs 7%; log-rank P = 0.018). In univariate analysis cardiovascular mortality for ES patients with septal substrate was 4.1-fold higher (HR: 4.192; CI: 1.194-14.719; P = 0.025). Independent predictors of adverse outcome in multivariable regression analysis were presence of septal substrate (HR: 5.723; P = 0.025) and increased age (HR: 1.104; P = 0.003). Recurrences of any ventricular arrhythmia (67% vs 56%; log rank P = 0.554) and rehospitalization rates (80% vs 66%; log rank P = 0.515) were similar between groups. Recurrences of clinical VT were similar (7% vs 2%; P = 0.252). CONCLUSIONS: Presence of a septal substrate is associated with adverse long-term cardiovascular mortality in patients admitted for VT ablation after ES. Despite decreased acute ablation successes in these patients, VT recurrence rates were similar to those without a septal substrate during follow-up.


Asunto(s)
Ablación por Catéter , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Masculino , Persona de Mediana Edad , Anciano , Femenino , Pronóstico , Isquemia Miocárdica/complicaciones , Arritmias Cardíacas/etiología , Ablación por Catéter/efectos adversos , Recurrencia
19.
J Interv Card Electrophysiol ; 65(2): 551-558, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35857220

RESUMEN

BACKGROUND: Although the ectopic foci responsible for initiating atrial fibrillation (AF) are usually located in the pulmonary veins (PVs), non-PV sources may initiate AF in approximately 11% of unselected patients with paroxysmal or persistent AF. The superior vena cava (SVC) is one of the most frequent non-PV origins for initiating AF. This study aims to investigate the effect of empirical SVC isolation in redo AF ablation procedures. METHODS: Consecutive patients undergoing redo AF ablation procedures using a high-power short-duration protocol (HPSD) (50 W; ablation index guided; target AI 350 for posterior wall ablation, AI 450 for anterior wall ablation; CARTO 3 mapping system) were included. Patients with SVC isolation were compared to patients without SVC isolation. Periprocedural parameters and complications were recorded and analyzed. Short-term endpoints included intrahospital AF recurrence, midterm endpoint AF freedom after 3 months, and long-term endpoint AF freedom after 12 months. RESULTS: A total of 276 patients underwent repeat ablation for recurrent AF (67 ± 10 years; 57% male; 31.5% paroxysmal AF). The patients were divided into two groups: redo procedures with SVC isolation vs redo procedure without SVC isolation. Additional LA substrate modification was done based on intraprocedural voltage maps. Baseline characteristics did not differ significantly between the two groups. Median procedure time was 85.4 ± 27.1 min with ablation times of 14.0 ± 8.5 min. Intrahospital AF recurrence occurred in 32 patients (12%) with no difference among both groups: 17 patients (13%) SVC vs 15 patients (10%) No-SVC; p = 0.416. At 3-month follow-up, 47 (17%) presented an AF recurrence during the blanking period: 25 patients (19%) SVC vs 22 patients (15%) No-SVC; p = 0.304). After 12 months, 202 (73%) of all patients were in stable sinus rhythm with no significant difference between the two groups: 93 patients (73%) SVC vs 109 patients (74%) No-SVC; p = 0.853). No significant differences were noted when dividing the patients in paroxysmal or persistent AF with and without SVC isolation. CONCLUSIONS: In our series of repeat AF ablation procedures, the addition of empirical SVC isolation to Re-PVI and LA substrate modification did not influence AF recurrence rates. This strategy can however be safe and useful in patients in whom SVC is identified as a trigger of AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Masculino , Femenino , Fibrilación Atrial/cirugía , Vena Cava Superior/cirugía , Recurrencia , Ablación por Catéter/métodos , Venas Pulmonares/cirugía , Resultado del Tratamiento
20.
J Cardiovasc Dev Dis ; 9(11)2022 Oct 25.
Artículo en Inglés | MEDLINE | ID: mdl-36354765

RESUMEN

Transcatheter edge-to-edge mitral valve repair (TEER) has become established as a safe and efficacious therapy for severe mitral regurgitation (MR) in high-risk patients. Despite its widespread use, postprocedural antithrombotic therapy (ATT) still to date is based on local expertise rather than evidence. In a multicenter, observational cohort study, 646 consecutive patients undergoing TEER were enrolled; 609 patients were successfully treated and antithrombotic therapy analyzed; 449 patients (73.7%) were previously treated with oral anticoagulants (OAC) due to the high prevalence of atrial fibrillation (459/609, 75.4%). Postprocedural ATT in patients previously treated with OAC consisted of no additional, additional single (SAPT) or dual antiplatelet therapy (DAPT) in 146/449 (33.6%), 248/449 (55.2%) and 55/449 (12.2%), respectively. There were 234/449 (52.1%) patients treated with vitamin-k antagonists (VKA) and 215/449 (47.9%) with nonvitamin-k antagonist oral anticoagulants (NOAC). One hundred sixty patients (26.3%) had no prior indication for OAC and were predominantly treated with DAPT (132/160, 82.5%). Use of SAPT (17/160, 10.6%) and no APT (11/160, 6.9%) was marginal. No statistically significant differences in terms of in-hospital mortality or the rate of major adverse cardiac and cerebrovascular events (MACCE) between the different antithrombotic therapy regimens were observed. Multiple Cox regression analysis showed a statistically significant decreased risk for all-cause mortality after a median follow-up of 419 days for OAC monotherapy (HR 0.6, 95%-CI 0.5-0.9, p = 0.04). This study provides evidence for a more favorable long-term outcome of OAC monotherapy in patients with an indication for OAC and reiterates the urgent need for randomized controlled trials on the optimal antithrombotic treatment of TEER patients.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA