Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 99
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur J Neurol ; 31(1): e16066, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37738525

RESUMEN

BACKGROUND AND PURPOSE: Vestibular symptoms are common in emergency department (ED) patients and have various causes, including stroke. Accurate identification of stroke in patients with vestibular symptoms is crucial for timely management. We conducted a prospective cross-sectional study from 2015 to 2019 to determine stroke prevalence and associated symptoms in ED patients with vestibular symptoms, aiming to improve diagnosis and outcomes. METHODS: As part of the DETECT project, we screened 1647 ED patients with acute vestibular symptoms. Following a retrospective analysis of 961 head and neck magnetic resonance imaging (MRI) scans, we included 122 confirmed stroke cases and assessed them for vestibular signs and symptoms. RESULTS: Stroke prevalence in dizzy patients was 13% (122/961 MRI scans). Most patients (95%) presented with acute vestibular symptoms with or without nystagmus, whereas 5% had episodic vestibular syndrome (EVS). Nystagmus was present in 50% of stroke patients. Eighty percent had a purely posterior circulation stroke, and nystagmus was absent in 46% of these patients. Seven patients (6%) had lesions in both the anterior and posterior circulation. Vertigo was experienced by 52% regardless of territory. CONCLUSIONS: A stroke was identified in 13% of ED patients presenting with acute vestibular symptoms. In 5%, it was EVS. Most strokes were in the posterior circulation territory; vertigo occurred with similar frequency in anterior and posterior circulation stroke, and absence of nystagmus was common in both.


Asunto(s)
Nistagmo Patológico , Accidente Cerebrovascular , Enfermedades Vestibulares , Humanos , Mareo/epidemiología , Mareo/etiología , Estudios Retrospectivos , Estudios Transversales , Estudios Prospectivos , Vértigo/etiología , Vértigo/complicaciones , Enfermedades Vestibulares/complicaciones , Enfermedades Vestibulares/diagnóstico , Enfermedades Vestibulares/epidemiología , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/epidemiología , Nistagmo Patológico/epidemiología , Nistagmo Patológico/etiología
2.
Crit Care ; 28(1): 215, 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38956665

RESUMEN

BACKGROUND: Despite advances in resuscitation practice, patient survival following cardiac arrest remains poor. The utilization of MRI in neurological outcome prognostication post-cardiac arrest is growing and various classifications has been proposed; however a consensus has yet to be established. MRI, though valuable, is resource-intensive, time-consuming, costly, and not universally available. This study aims to validate a MRI lesion pattern score in a cohort of out of hospital cardiac arrest patients at a tertiary referral hospital in Switzerland. METHODS: This cohort study spanned twelve months from February 2021 to January 2022, encompassing all unconscious patients aged ≥ 18 years who experienced out-of-hospital cardiac arrest of any cause and were admitted to the intensive care unit (ICU) at Inselspital, University Hospital Bern, Switzerland. We included patients who underwent the neuroprognostication process, assessing the performance and validation of a MRI scoring system. RESULTS: Over the twelve-month period, 137 patients were admitted to the ICU, with 52 entering the neuroprognostication process and 47 undergoing MRI analysis. Among the 35 MRIs indicating severe hypoxic brain injury, 33 patients (94%) experienced an unfavourable outcome (UO), while ten (83%) of the twelve patients with no or minimal MRI lesions had a favourable outcome. This yielded a sensitivity of 0.94 and specificity of 0.83 for predicting UO with the proposed MRI scoring system. The positive and negative likelihood ratios were 5.53 and 0.07, respectively, resulting in an accuracy of 91.49%. CONCLUSION: We demonstrated the effectiveness of the MLP scoring scheme in predicting neurological outcome in patients following cardiac arrest. However, to ensure a comprehensive neuroprognostication, MRI results need to be combined with other assessments. While neuroimaging is a promising objective tool for neuroprognostication, given the absence of sedation-related confounders-compared to electroencephalogram (EEG) and clinical examination-the current lack of a validated scoring system necessitates further studies. Incorporating standardized MRI techniques and grading systems is crucial for advancing the reliability of neuroimaging for neuroprognostication. TRIAL REGISTRATION: Registry of all Projects in Switzerland (RAPS) 2020-01761.


Asunto(s)
Imagen por Resonancia Magnética , Paro Cardíaco Extrahospitalario , Humanos , Imagen por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/estadística & datos numéricos , Masculino , Paro Cardíaco Extrahospitalario/terapia , Paro Cardíaco Extrahospitalario/diagnóstico por imagen , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Anciano , Suiza , Estudios de Cohortes , Unidades de Cuidados Intensivos/organización & administración , Unidades de Cuidados Intensivos/estadística & datos numéricos , Valor Predictivo de las Pruebas , Pronóstico , Adulto
3.
Eur Arch Otorhinolaryngol ; 281(4): 1781-1787, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37943315

RESUMEN

OBJECTIVES: To assess the prevalence of new hearing losses in patients with acute vestibular syndrome (AVS) and to start to evaluate its diagnostic value for the differentiation between peripheral and central causes. DESIGN: We performed a cross-sectional prospective study in AVS patients presenting to our Emergency Department (ED) from February 2015 to November 2020. All patients received an MRI, Head-impulse test, Nystagmus test and Test of skew ('HINTS'), caloric testing and a pure-tone audiometry. RESULTS: We assessed 71 AVS patients, 17 of whom had a central and 54 a peripheral cause of dizziness. 12.7% had an objective hearing loss. 'HINTS' had an accuracy of 78.9% to diagnose stroke, whereas 'HINTS' plus audiometry 73.2%. 'HINTS' sensitivity was 82.4% and specificity 77.8% compared to 'HINTS' plus audiometry showing a sensitivity of 82.4% and specificity of 70.4%. The four patients with stroke and minor stroke had all central 'HINTS'. 55% of the patients did not perceive their new unilateral hearing loss. CONCLUSIONS: We found that almost one-eighth of the AVS patients had a new onset of hearing loss and only half had self-reported it. 'HINTS' plus audiometry proved to be less accurate to diagnose a central cause than 'HINTS' alone. Audiometry offered little diagnostic accuracy to detect strokes in the ED but might be useful to objectify a new hearing loss that was underestimated in the acute phase. Complete hearing loss should be considered a red flag, as three in four patients suffered from a central cause.


Asunto(s)
Sordera , Pérdida Auditiva , Nistagmo Patológico , Accidente Cerebrovascular , Humanos , Estudios Transversales , Prevalencia , Estudios Prospectivos , Vértigo/etiología , Náusea/complicaciones , Vómitos/complicaciones , Pérdida Auditiva/diagnóstico , Pérdida Auditiva/epidemiología , Enfermedad Aguda , Accidente Cerebrovascular/complicaciones , Nistagmo Patológico/diagnóstico
4.
Hum Brain Mapp ; 44(3): 970-979, 2023 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-36250711

RESUMEN

Brain morphometry is usually based on non-enhanced (pre-contrast) T1-weighted MRI. However, such dedicated protocols are sometimes missing in clinical examinations. Instead, an image with a contrast agent is often available. Existing tools such as FreeSurfer yield unreliable results when applied to contrast-enhanced (CE) images. Consequently, these acquisitions are excluded from retrospective morphometry studies, which reduces the sample size. We hypothesize that deep learning (DL)-based morphometry methods can extract morphometric measures also from contrast-enhanced MRI. We have extended DL+DiReCT to cope with contrast-enhanced MRI. Training data for our DL-based model were enriched with non-enhanced and CE image pairs from the same session. The segmentations were derived with FreeSurfer from the non-enhanced image and used as ground truth for the coregistered CE image. A longitudinal dataset of patients with multiple sclerosis (MS), comprising relapsing remitting (RRMS) and primary progressive (PPMS) subgroups, was used for the evaluation. Global and regional cortical thickness derived from non-enhanced and CE images were contrasted to results from FreeSurfer. Correlation coefficients of global mean cortical thickness between non-enhanced and CE images were significantly larger with DL+DiReCT (r = 0.92) than with FreeSurfer (r = 0.75). When comparing the longitudinal atrophy rates between the two MS subgroups, the effect sizes between PPMS and RRMS were higher with DL+DiReCT both for non-enhanced (d = -0.304) and CE images (d = -0.169) than for FreeSurfer (non-enhanced d = -0.111, CE d = 0.085). In conclusion, brain morphometry can be derived reliably from contrast-enhanced MRI using DL-based morphometry tools, making additional cases available for analysis and potential future diagnostic morphometry tools.


Asunto(s)
Esclerosis Múltiple Recurrente-Remitente , Esclerosis Múltiple , Humanos , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Estudios Retrospectivos , Encéfalo/diagnóstico por imagen , Encéfalo/patología , Imagen por Resonancia Magnética/métodos , Atrofia/patología , Esclerosis Múltiple Recurrente-Remitente/patología
5.
Artículo en Inglés | MEDLINE | ID: mdl-37555808

RESUMEN

OBJECTIVES: To investigate the diagnostic performance of diffusion-weighted imaging (DWI) of the superficial cranial arteries in the diagnosis of giant cell arteritis (GCA). METHODS: Retrospectively, 156 patients with clinically suspected GCA were included. A new 4-point ordinal DWI rating scale was developed. A post-contrast, fat-suppressed, T1-weighted "black-blood" sequence (T1-BB) was rated for comparison. Ten arterial segments were assessed: common superficial temporal arteries, temporal and parietal branches, occipital and posterior auricular arteries bilaterally. The expert clinical diagnosis after ≥ 6 months of follow-up was the diagnostic reference standard. Diagnostic accuracy was evaluated for different rating methods. RESULTS: The study cohort consisted of 87 patients with and 69 without GCA. For DWI, the area under the curve was 0.90. For a cut-off of ≥ 2 consecutive pathological slices, DWI showed a sensitivity of 75.9%, a specificity of 94.2% and a positive likelihood ratio of 13.09. With a cut-off of ≥ 3 consecutive pathological slices, sensitivity was 70.1%, specificity was 98.6%, and the positive likelihood ratio was 48.38. For the T1-BB, values were 88.5%, 88.4% and 7.63, respectively. The inter-rater analysis for DWI with a cut-off of ≥ 2 pathological slices showed a kappa of 1.00 on the patient level and 0.85 on the arterial segment level. For the T1-BB the kappa was 0.78 and 0.79, respectively. CONCLUSION: DWI of the superficial cranial arteries demonstrates a good diagnostic accuracy and reliability for the diagnosis of GCA. DWI is widely available and can be used immediately in clinical practice for patients with suspected GCA.

6.
J Magn Reson Imaging ; 58(3): 864-876, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-36708267

RESUMEN

BACKGROUND: Detecting new and enlarged lesions in multiple sclerosis (MS) patients is needed to determine their disease activity. LeMan-PV is a software embedded in the scanner reconstruction system of one vendor, which automatically assesses new and enlarged white matter lesions (NELs) in the follow-up of MS patients; however, multicenter validation studies are lacking. PURPOSE: To assess the accuracy of LeMan-PV for the longitudinal detection NEL white-matter MS lesions in a multicenter clinical setting. STUDY TYPE: Retrospective, longitudinal. SUBJECTS: A total of 206 patients with a definitive MS diagnosis and at least two follow-up MRI studies from five centers participating in the Swiss Multiple Sclerosis Cohort study. Mean age at first follow-up = 45.2 years (range: 36.9-52.8 years); 70 males. FIELD STRENGTH/SEQUENCE: Fluid attenuated inversion recovery (FLAIR) and T1-weighted magnetization prepared rapid gradient echo (T1-MPRAGE) sequences at 1.5 T and 3 T. ASSESSMENT: The study included 313 MRI pairs of datasets. Data were analyzed with LeMan-PV and compared with a manual "reference standard" provided by a neuroradiologist. A second rater (neurologist) performed the same analysis in a subset of MRI pairs to evaluate the rating-accuracy. The Sensitivity (Se), Specificity (Sp), Accuracy (Acc), F1-score, lesion-wise False-Positive-Rate (aFPR), and other measures were used to assess LeMan-PV performance for the detection of NEL at 1.5 T and 3 T. The performance was also evaluated in the subgroup of 123 MRI pairs at 3 T. STATISTICAL TESTS: Intraclass correlation coefficient (ICC) and Cohen's kappa (CK) were used to evaluate the agreement between readers. RESULTS: The interreader agreement was high for detecting new lesions (ICC = 0.97, Pvalue < 10-20 , CK = 0.82, P value = 0) and good (ICC = 0.75, P value < 10-12 , CK = 0.68, P value = 0) for detecting enlarged lesions. Across all centers, scanner field strengths (1.5 T, 3 T), and for NEL, LeMan-PV achieved: Acc = 61%, Se = 65%, Sp = 60%, F1-score = 0.44, aFPR = 1.31. When both follow-ups were acquired at 3 T, LeMan-PV accuracy was higher (Acc = 66%, Se = 66%, Sp = 66%, F1-score = 0.28, aFPR = 3.03). DATA CONCLUSION: In this multicenter study using clinical data settings acquired at 1.5 T and 3 T, and variations in MRI protocols, LeMan-PV showed similar sensitivity in detecting NEL with respect to other recent 3 T multicentric studies based on neural networks. While LeMan-PV performance is not optimal, its main advantage is that it provides automated clinical decision support integrated into the radiological-routine flow. EVIDENCE LEVEL: 4 TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Esclerosis Múltiple , Sustancia Blanca , Masculino , Humanos , Adulto , Persona de Mediana Edad , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/patología , Estudios de Cohortes , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Encéfalo/patología
7.
Mult Scler ; 29(1): 63-73, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36113094

RESUMEN

BACKGROUND: Leptomeningeal inflammation in patients with multiple sclerosis (MS) mainly affects meningeal B-cell follicle-like structures linked to cortical and subpial lesions and can be visualized as leptomeningeal enhancement (LME). OBJECTIVE: To evaluate the evolution of LME under different MS immunotherapies. METHODS: A total of 214 MS patients treated with anti-CD20 therapies or fingolimod at the university hospital Bern were screened for LME. Magnetic resonance imaging (MRI) and medical records were retrospectively evaluated, and comparative statistics were applied. RESULTS: We compared MS patients treated with anti-CD20 therapies (128 patients (59.8%)) or fingolimod (86 patients (40.2%)). Of 128 anti-CD20-treated patients, 108 (84.4%) had no LME, 11 (8.6%) had persistent LME, and 9 (7.0%) showed resolution of LME. Of 86 fingolimod-treated MS patients, 81 (94.2%) had no LME and 5 (5.8%) persistent LME. Patients with LME persistence were older than those without or resolution of LME (p = 0.039). Resolution of LME was more frequent during anti-CD20 compared with fingolimod treatment (p = 0.019). CONCLUSION: We observed LME resolution under treatment with anti-CD20 therapies. As LME might play an important role in cerebral gray matter pathology in MS, further investigations including extensions to higher field strengths, correlation with clinical phenotypes, and comparison with other immunotherapies are needed.


Asunto(s)
Clorhidrato de Fingolimod , Esclerosis Múltiple , Humanos , Estudios Retrospectivos , Clorhidrato de Fingolimod/uso terapéutico , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/tratamiento farmacológico , Esclerosis Múltiple/patología , Meninges/diagnóstico por imagen , Meninges/patología , Imagen por Resonancia Magnética/métodos , Inmunoterapia
8.
Eur Radiol ; 2023 Nov 13.
Artículo en Inglés | MEDLINE | ID: mdl-37953368

RESUMEN

OBJECTIVE: To assess the accuracy of CT and MRI reports of alert patients presenting after non-self-inflicted strangulation (NSIS) and evaluate the appropriateness of these imaging modalities in NSIS. MATERIAL AND METHODS: The study was a retrospective analysis of patient characteristics and strangulation details, with a comparison of original radiology reports (ORR) to expert read-outs (EXR) of CT and MRI studies of all NSIS cases seen from 2008 to 2020 at a single centre. RESULTS: The study included 116 patients (71% women, p < .001, χ2), with an average age of 33.8 years, mostly presenting after manual strangulation (97%). Most had experienced intimate partner violence (74% of women, p < .001, χ2) or assault by unknown offender (88% of men, p < 0.002 χ2). Overall, 132 imaging studies (67 CT, 51% and 65 MRI, 49%) were reviewed. Potentially dangerous injuries were present in 7%, minor injuries in 22%, and no injuries in 71% of patients. Sensitivity and specificity of ORR were 78% and 97% for MRI and 30% and 98% for CT. Discrepancies between ORR and EXR occurred in 18% of all patients, or 62% of injured patients, with a substantial number of unreported injuries on CT. CONCLUSIONS: The results indicate that MRI is more appropriate than CT for alert patients presenting after non-self-inflicted strangulation and underline the need for radiologists with specialist knowledge to report these cases in order to add value to both patient care and potential future medico-legal investigations. CLINICAL RELEVANCE STATEMENT: MRI should be preferred over CT for the investigation of strangulation related injuries in alert patients because MRI has a higher accuracy than CT and does not expose this usually young patient population to ionizing radiation. KEY POINTS: • Patients presenting after strangulation are often young women with a history of intimate partner violence while men typically present after assault by an unknown offender. • Expert read-outs of CT and MRI revealed potentially dangerous injuries in one of 14 patients. • MRI has a significantly higher sensitivity than CT and appears to be more appropriate for the diagnostic workup of alert patients after strangulation.

9.
Ear Hear ; 44(6): 1379-1388, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37157125

RESUMEN

OBJECTIVES: Reliable determination of cochlear implant electrode positions shows promise for clinical applications, including anatomy-based fitting of audio processors or monitoring of electrode migration during follow-up. Currently, electrode positioning is measured using radiography. The primary objective of this study is to extend and validate an impedance-based method for estimating electrode insertion depths, which could serve as a radiation-free and cost-effective alternative to radiography. The secondary objective is to evaluate the reliability of the estimation method in the postoperative follow-up over several months. DESIGN: The ground truth insertion depths were measured from postoperative computed tomography scans obtained from the records of 56 cases with an identical lateral wall electrode array. For each of these cases, impedance telemetry records were retrieved starting from the day of implantation up to a maximum observation period of 60 mo. Based on these recordings, the linear and angular electrode insertion depths were estimated using a phenomenological model. The estimates obtained were compared with the ground truth values to calculate the accuracy of the model. RESULTS: Analysis of the long-term recordings using a linear mixed-effects model showed that postoperative tissue resistances remained stable throughout the follow-up period, except for the two most basal electrodes, which increased significantly over time (electrode 11: ~10 Ω/year, electrode 12: ~30 Ω/year). Inferred phenomenological models from early and late impedance telemetry recordings were not different. The insertion depth of all electrodes was estimated with an absolute error of 0.9 mm ± 0.6 mm or 22° ± 18° angle (mean ± SD). CONCLUSIONS: Insertion depth estimations of the model were reliable over time when comparing two postoperative computed tomography scans of the same ear. Our results confirm that the impedance-based position estimation method can be applied to postoperative impedance telemetry recordings. Future work needs to address extracochlear electrode detection to increase the performance of the method.


Asunto(s)
Implantación Coclear , Implantes Cocleares , Humanos , Impedancia Eléctrica , Reproducibilidad de los Resultados , Cóclea/cirugía , Implantación Coclear/métodos
10.
Eur Arch Otorhinolaryngol ; 280(1): 131-136, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35695918

RESUMEN

PURPOSE: This study aimed to investigate the variability of the retrotympanum in patients undergoing surgical treatment for cholesteatoma. METHODS: We included 59 ears of patients undergoing middle ear surgery for cholesteatoma who had preoperative computed tomography scans. A retrospective analysis of the medical records was conducted. The sinus tympani (ST), subtympanic sinus (STS) and facial recess (FR) were classified into types A-C based on the relationship of their extension to the facial nerve. The mastoid and petrous apex were assessed and categorized as normal pneumatized or sclerotic. RESULTS: Type A extension was the most frequently found in all sinuses (ST 64%, FR 77%, STS 69%), Type B extension was found more often in ST (34%) and STS (24%) than in FR (15%). A very deep extension was found only rarely (ST 2%, FR 8%, STS 7%). A sclerotic mastoid was found in 67% of cases. Those cases showed a statistically significant difference regarding retrotympanum pneumatization when compared with normal mastoid. CONCLUSION: The most frequent variant of retrotympanic pneumatization in relation to the facial nerve was type A in all subsites in cholesteatoma patients. The variability among patients with cholesteatoma is different to previously published results in healthy subjects. Moreover, the pneumatization of the retrotympanum is associated with mastoid pneumatization.


Asunto(s)
Colesteatoma , Apófisis Mastoides , Humanos , Apófisis Mastoides/diagnóstico por imagen , Apófisis Mastoides/cirugía , Estudios Retrospectivos , Colesteatoma/diagnóstico por imagen , Colesteatoma/cirugía , Oído Medio , Hueso Petroso
11.
Audiol Neurootol ; 27(6): 449-457, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36037798

RESUMEN

INTRODUCTION: The aim of this study is to evaluate signal alteration in the inner ear using three-dimensional (3D)-constructive interference in steady state (CISS) sequence in patients with Ménière's disease and labyrinthitis and its correlation with clinical and audiological parameters. METHODS: The medical records of the department of otorhinolaryngology were searched for patients with Ménière's disease or labyrinthitis who underwent MRI with 3D-CISS sequence. Blinded analysis of these patients and of MRI from control subjects without middle or inner ear symptoms was performed to detect any signal asymmetry of the inner ear structures. The results were correlated with clinical symptoms and results of audiological and vestibular tests. RESULTS: Fifty-eight patients with definite Ménière's disease and 5 patients with labyrinthitis as well as 41 control exams were included. A separate analysis was performed for patients with probable Ménière's disease (n = 68). A total of 172 3D-CISS sequences were analyzed by 2 blinded independent neuroradiologists. A CISS-hypointense signal of the inner ear structures was found in 3 patients with definite Ménière's disease (5.2%), in 4 patients with probable Ménière's disease (5.9%), and 2 patients with labyrinthitis (40%). No CISS hypointensity was found in the control group. Although no significant difference in symptoms or audiological test results was found between patients with and without this signal change, the side of hypointensity was frequently correlated with the symptomatic side and with hearing impairment. DISCUSSION/CONCLUSION: CISS hypointensity of the inner ear structures was evident in patients with clinical conditions other than vestibular schwannoma - more frequently in labyrinthitis than in Ménière's disease. This signal alteration was frequently encountered on the same symptomatic side as that of the pathological audiology tests, but it is not a predictor for hearing or vestibular impairment.


Asunto(s)
Oído Interno , Hidropesía Endolinfática , Laberintitis , Enfermedad de Meniere , Humanos , Enfermedad de Meniere/diagnóstico por imagen , Laberintitis/diagnóstico por imagen , Laberintitis/patología , Oído Interno/diagnóstico por imagen , Oído Interno/patología , Imagen por Resonancia Magnética
12.
BMC Med Imaging ; 22(1): 191, 2022 11 07.
Artículo en Inglés | MEDLINE | ID: mdl-36344914

RESUMEN

Imaging of parotid gland tumors is challenging due to the wide variety of differential diagnoses. Malignant parotid tumors can have very similar features to benign ones, such as slow growth and displacement instead of infiltration of neighboring structures. Malignant and benign tumors may therefore not be clinically distinguishable. Correct characterization of parotid tumors (i.e., benign or malignant) determines preoperative treatment planning and is important in optimizing the individualized surgical plan. Magnetic resonance imaging (MRI) is the imaging modality of choice for evaluation of suspected parotid gland lesions and differentiation between benign and malignant lesions. Certain conventional MRI features can suggest whether a mass is more likely to be a benign or low-grade malignancy or a high-grade malignancy and adding diffusion-weighted imaging or advanced MRI techniques like perfusion can aid in this distinction. Morphological features seen on MRI, such as low signal on T2-w, infiltrative changes or ill-defined margins, change over time and diffusion restriction can point to the malignant nature of the lesion. MRI is useful for detection and localization of the lesion(s), and associated findings like perineural spread of tumor, lymph node involvement and infiltrative changes of the surrounding tissues. In this pictorial essay, we present selected images of a variety of benign and malignant parotid tumors and emphasize the MRI features that may be useful in their characterization.


Asunto(s)
Neoplasias de la Parótida , Humanos , Neoplasias de la Parótida/diagnóstico por imagen , Glándula Parótida , Imagen por Resonancia Magnética/métodos , Imagen de Difusión por Resonancia Magnética , Diagnóstico Diferencial , Estudios Retrospectivos
13.
Eur Arch Otorhinolaryngol ; 279(10): 4793-4799, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35072767

RESUMEN

PURPOSE: The use of magnetic resonance imaging (MRI) is often limited in patients with auditory implants because of the presence of metallic components and magnets. The aim of this study was to evaluate the clinical usefulness of a customized MRI sequence for metal artifact suppression in patients with BONEBRIDGETM BCI 602 implants (MED-EL, Innsbruck, Austria), the successor of the BCI 601 model. METHODS: Using our in-house developed and customized metal artifact reduction sequence (SEMAC-VAT WARP), MRI artifacts were evaluated qualitatively and quantitatively. MRI sequences were performed with and without artifact reduction on two whole head specimens with and without the BCI 602 implant. In addition, the influence of two different implantation sites (mastoid versus retrosigmoid) and head orientation on artifact presence was investigated. RESULTS: Artifact volume was reduced by more than the 50%. Results were comparable with those obtained with the BCI 601, showing no significant differences in the dimensions of artifacts caused by the implant. CONCLUSION: SEMAC-VAT WARP was once more proved to be efficient at reducing metal artifacts on MR images. The dimensions of artifacts associated with the BCI 602 are not smaller than those caused by the BCI 601.


Asunto(s)
Artefactos , Conducción Ósea , Humanos , Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Metales , Prótesis e Implantes
14.
Eur J Neurol ; 28(9): 2971-2979, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34176187

RESUMEN

OBJECTIVE: Gaze-evoked nystagmus (GEN) is a central sign in patients with the acute vestibular syndrome (AVS); however, discriminating between a pathological and a physiologic GEN is a challenge. Here we evaluate GEN in patients with AVS. METHODS: In this prospective cross-sectional study, we used video-oculography (VOG) to compare GEN in the light (target at 15° eccentric) in 64 healthy subjects with 47 patients seen in the emergency department (ED) who had AVS; 35 with vestibular neuritis and 12 with stroke. All patients with an initial non-diagnostic MRI received a confirmatory, delayed MRI as a reference standard in detecting stroke. RESULTS: Healthy subjects with GEN had a time constant of centripetal drift >18 s. VOG identified pathologic GEN (time constant ≤ 18 s) in 33% of patients with vestibular strokes, specificity was 100%, accuracy was 83%. Results were equivalent to examination by a clinical expert. As expected, since all patients with GEN had a SN in straight-ahead position, they showed the pattern of a Bruns' nystagmus. CONCLUSIONS: One third of patients with AVS due to central vestibular strokes had a spontaneous SN in straight-ahead gaze and a pathological GEN, producing the pattern of a Bruns' nystagmus with a shift of the null position. The localization of the side of the lesion based on the null was not consistent, presumably because the circuits underlying gaze-holding are widespread in the brainstem and cerebellum. Nevertheless, automated quantification of GEN with VOG was specific, and accurately identified patients in the ED with AVS due to strokes.


Asunto(s)
Nistagmo Patológico , Accidente Cerebrovascular , Estudios Transversales , Humanos , Nistagmo Patológico/diagnóstico , Nistagmo Patológico/etiología , Estudios Prospectivos , Accidente Cerebrovascular/complicaciones , Accidente Cerebrovascular/diagnóstico por imagen , Vértigo
15.
Eur J Neurol ; 28(8): 2614-2621, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33983645

RESUMEN

BACKGROUND AND PURPOSE: A peripheral spontaneous nystagmus (SN) is typically enhanced or revealed by removing fixation. Conversely, failure of fixation suppression of SN is usually a sign of a central disorder. Based on Luebke and Robinson (Vision Res 1988, vol. 28 (8), pp. 941-946), who suggested that the normal fixation mechanism is disengaged during pursuit, it is hypothesized that vertical tracking in the light would bring out or enhance a horizontal SN. METHODS: Eighteen patients with acute vestibular neuritis were studied. Eye movements were recorded using video-oculography at straight-ahead gaze with and without visual fixation, and during smooth pursuit. The slow-phase velocity and the fixation suppression indices of nystagmus (relative to SN in darkness) were compared in each condition. RESULTS: During vertical tracking, the slow-phase velocity of horizontal SN with eyes near straight-ahead gaze was significantly higher (median 2.7°/s) than under static visual fixation (median 1.2°/s). Likewise, the fixation index was significantly higher (worse suppression) during pursuit (median 48%) than during fixation (median 26%). A release of SN was also suggested during horizontal pursuit, if one assumes superposition of SN on a normal and symmetrical pursuit capability.


Asunto(s)
Nistagmo Patológico , Seguimiento Ocular Uniforme , Movimientos Oculares , Fijación Ocular , Humanos
16.
Neurocrit Care ; 35(1): 197-209, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33326065

RESUMEN

BACKGROUND/OBJECTIVE: In order to monitor tissue oxygenation in patients with acute neurological disorders, probes for measurement of brain tissue oxygen tension (ptO2) are often placed non-specifically in a right frontal lobe location. To improve the value of ptO2 monitoring, placement of the probe into a specific area of interest is desirable. We present a technique using CT-guidance to place the ptO2 probe in a particular area of interest based on the individual patient's pathology. METHODS: In this retrospective cohort study, we analyzed imaging and clinical data from all patients who underwent CT-guided ptO2 probe placement at our institution between October 2017 and April 2019. Primary endpoint was successful placement of the probe in a particular area of interest rated by two independent reviewers. Secondary outcomes were complications from probe insertion, clinical consequences from ptO2 measurements, clinical outcome according to the modified Rankin Scale (mRS) as well as development of ischemia on follow-up imaging. A historical control group was selected from patients who underwent conventional ptO2 probe placement between January 2010 and October 2017. RESULTS: Eleven patients had 16 CT-guided probes inserted. In 15 (93.75%) probes, both raters agreed on the correct placement in the area of interest. Each probe triggered on average 0.48 diagnostic or therapeutic adjustments per day. Only one infarction within the vascular territory of a probe was found on follow-up imaging. Eight out of eleven patients (72.73%) reached a good outcome (mRS ≤ 3). In comparison, conventionally placed probes triggered less diagnostic and therapeutic adjustment per day (p = 0.007). Outcome was worse in the control group (p = 0.024). CONCLUSION: CT-guided probe insertion is a reliable and easy technique to place a ptO2 probe in a particular area of interest in patients with potentially reduced cerebral oxygen supply. By adjusting treatment aggressively according to this individualized monitoring data, clinical outcome may improve.


Asunto(s)
Encéfalo , Oxígeno , Encéfalo/diagnóstico por imagen , Humanos , Microcirugia , Monitoreo Fisiológico , Estudios Retrospectivos
17.
BMC Emerg Med ; 20(1): 70, 2020 08 31.
Artículo en Inglés | MEDLINE | ID: mdl-32867677

RESUMEN

BACKGROUND: Vestibular symptoms are a frequent reason for presenting at the emergency department (ED). Underlying conditions range in severity from life-threatening to benign, but often remain undiagnosed despite extensive investigations. We aimed to identify clinical characteristics that are associated with ED consultations by patients with vestibular symptoms of unknown origin (VUO) and to quantify the ED resources consumed during the investigations. METHODS: This retrospective one-year, single-centre, cross-sectional study assessed ED consultations with patients whose chief complaint was 'vestibular symptoms'. Data on risk factors, clinical characteristics, management and ED resources were extracted from the administrative database and medical records. Consultations were grouped according to the discharge diagnosis as either VUO or non-VUO. We determined clinical factors associated with VUO and compared ED resource consumption by the two patient groups using multivariable analysis. RESULTS: A total of 1599 ED consultations were eligible. Of these, 14.3% (n = 229) were consultations with patients with VUO. Clinical characteristics included in the final multivariable model to determine associations with VUO were sensory disorders, aural fullness, improvement at rest, absence of situational provocation, pre-existing neurological conditions, and age < 65 years. Patients with VUO had higher total ED resource consumption in terms of physicians' work and radiology resources, as a result of more use of computed tomography and magnetic resonance imaging. CONCLUSION: One in seven emergency patients with vestibular symptoms is dismissed without a diagnosis. Clinical characteristics of VUO patients are distinct from patients in whom a diagnosis was made in the ED. VUO triggers higher ED resource consumption, which can be justified if appropriately indicated.


Asunto(s)
Servicio de Urgencia en Hospital , Necesidades y Demandas de Servicios de Salud , Enfermedades Vestibulares/diagnóstico , Adulto , Anciano , Estudios Transversales , Diagnóstico Diferencial , Diagnóstico por Imagen/estadística & datos numéricos , Mareo/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Parestesia/diagnóstico , Estudios Retrospectivos , Factores de Riesgo , Suiza , Vértigo/diagnóstico
18.
19.
Audiol Neurootol ; 24(2): 56-64, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31067530

RESUMEN

OBJECTIVE: Magnetic resonance imaging (MRI) is often limited in patients with auditory implants because of the presence of metallic components and magnets. The aim of this study was to evaluate the clinical usefulness of a customized MRI sequence for metal artifact suppression for patients with implants in the temporal bone region, specifically patients with a transcutaneous bone conduction implant. METHODS: Two whole head specimens were unilaterally implanted with a transcutaneous bone conduction implant. MRI examinations with and without a primarily self-build sequence (SEMAC-VAT WARP) for metal artifact suppression were performed. The diagnostic usefulness of the acquired MRI scans was rated independently by two neuroradiologists. The sequence was also used to acquire postimplantation follow-up MRI in a patient with a transcutaneous bone conduction implant. RESULTS: The customized SEMAC-VAT WARP sequence significantly improved the diagnostic usefulness of the postimplantation MRIs. The image acquisition time was 12 min and 20 s for the T1-weighted and 12 min and 12 s for the T2-weighted MRI. There was good agreement between the two blinded raters (Cohen's κ = 0.61, p < 0.001). CONCLUSION: The sequence for metal artifact reduction optimized in Bern enables MRI at 1.5 T in patients with active transcutaneous bone conduction implants without sacrificing diagnostic imaging quality. Particularly on the implanted side, imaging of intracranial and supra- and infratentorial brain pathologies is clinically more valuable than standard diagnostic MRI without any artifact reduction sequences.


Asunto(s)
Artefactos , Conducción Ósea , Implantes Cocleares , Imagen por Resonancia Magnética/métodos , Metales , Humanos , Interpretación de Imagen Asistida por Computador , Masculino , Persona de Mediana Edad , Diseño de Prótesis
20.
Stroke ; 49(11): 2643-2651, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30355192

RESUMEN

Background and Purpose- Sustained successful reperfusion is an important prognostic factor for good clinical outcome in acute ischemic stroke. We aimed to identify the prevalence, clinical impact, and predictors of early reocclusion after initially successful thrombectomies within a prospective cohort. Methods- A total of 711 stroke patients with successful reperfusion (modified Thrombolysis in Cerebral Infarction, 2b/3) followed with magnetic resonance or computed tomographic angiography at 24 to 48 hours were included. Multivariable logistic regression analysis was used to evaluate associated factors and clinical impact. Results are displayed as adjusted odds ratio (aOR) and 95% CI. Improvement in accuracy of additional imaging findings on angiography control runs after the intervention was evaluated by area under the curve. Results- Early reocclusion was observed in 16 of 711 successfully reperfused patients (2.3%; 95% CI, 1.1-3.3; median delay: 20 hours). Suggestive predictors were higher platelets on admission (aOR, 1.01; 95% CI, 1.01-1.02), prestroke functional dependence (aOR, 7.12; 95% CI, 1.49-34.03), and stroke of undetermined or other specified pathogenesis in the TOAST classification (aOR, 7.19; 95% CI, 1.10-47.05 and aOR, 36.50; 95% CI, 4.47-298.11, respectively). When implementing residual embolic fragments or stenosis at the thrombectomy site into the logistic regression model, discrimination between patients with and without reocclusion improved significantly (area under the curve, 0.955 versus 0.854; P=0.023). Early reocclusion was an independent predictor of unfavorable outcome at 90 days (aOR for modified Rankin Scale ≤2, 0.13; 95% CI, 0.03-0.57). Conclusions- Early reocclusion within 48 hours after successful mechanical thrombectomy is rare but associated with poor outcome. Patients with high platelets on admission and residual embolic fragments or stenosis at the thrombectomy site are at high risk for reocclusion, which may be prevented or corrected after carefully re-evaluating the last angiographic run.


Asunto(s)
Isquemia Encefálica/cirugía , Trombosis de las Arterias Carótidas/cirugía , Procedimientos Endovasculares , Infarto de la Arteria Cerebral Media/cirugía , Accidente Cerebrovascular/cirugía , Trombectomía , Anciano , Anciano de 80 o más Años , Área Bajo la Curva , Isquemia Encefálica/sangre , Isquemia Encefálica/diagnóstico por imagen , Trombosis de las Arterias Carótidas/sangre , Trombosis de las Arterias Carótidas/diagnóstico por imagen , Angiografía Cerebral , Angiografía por Tomografía Computarizada , Constricción Patológica , Femenino , Humanos , Infarto de la Arteria Cerebral Media/sangre , Infarto de la Arteria Cerebral Media/diagnóstico por imagen , Modelos Logísticos , Angiografía por Resonancia Magnética , Masculino , Persona de Mediana Edad , Análisis Multivariante , Recuento de Plaquetas , Recurrencia , Factores de Riesgo , Accidente Cerebrovascular/sangre , Accidente Cerebrovascular/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA