1.
Clin Chim Acta ; 556: 117821, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38342424

RESUMEN

CONTEXT: Although immunoassay interference is a well-known phenomenon, its detection in routine clinical practice remains challenging. Most immunoassay interference can be attributed to the presence of heterophilic or anti-hormone antibodies. However, reports on immunoassay interference specifically related to parathyroid hormone (PTH) are scarce. CASE DESCRIPTION: A 77-year-old woman with hypertension, nephrotic syndrome, and high PTH levels for one year was admitted to our Surgical Department for treatment. The patient had no specific symptoms and normal calcium and alkaline phosphatase (ALP) levels but markedly elevated PTH levels. PTH was 2172 pg/mL using the Beckman Coulter system, whereas the Roche, Abbot, and Siemens systems yielded normal results. PTH concentration decreased to 63.8 pg/mL after pretreatment with polyethylene glycol 6000 and did not decrease to normal levels following pretreatment with heterophilic blocking tube-50 (HBT-50), heterophilic blocking reagent (HBR)-21, or HBR-25. When the HBR-21 concentration was increased, serum PTH decreased to 99.0 pg/mL. After treatment with scavenger bovine alkaline phosphatase (inactive), the concentration of PTH decreased to a normal value (51.3 pg/mL). Additionally, PTH (1-84) concentration was 17.6 pg/mL using LC-MS/MS. CONCLUSION: PTH was falsely evaluated due to anti-bovine ALP antibodies (antibodies against reagent ALP). Anti-bovine ALP antibodies should be considered in assays that use ALP as a signal generator.


Asunto(s)
Fosfatasa Alcalina , Espectrometría de Masas en Tándem , Femenino , Humanos , Animales , Bovinos , Anciano , Indicadores y Reactivos , Cromatografía Liquida , Hormona Paratiroidea , Anticuerpos
2.
J Steroid Biochem Mol Biol ; 244: 106596, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-39089343

RESUMEN

Since steroids are crucial for diagnosing endocrine disorders, the lack of research on factors that affect hormone levels makes interpreting the results difficult. Our study aims to assess the stability of the pre-analytical procedure and the impact of hormonal physiological fluctuations using real-world data. The datasets were created using 12,418 records from individuals whose steroid hormone measurements were taken in our laboratory between September 2019 and March 2024. 22 steroid hormones in plasma by a well-validated liquid chromatography tandem mass spectrometry method were measured. After normalization transformation, outlier removal, and z-score normalization, generalized additive models were constructed to evaluate preanalytic stability and age, sex, and sample time-dependent hormonal fluctuations. Most hormones exhibit significant variability with age, particularly steroid hormone precursors, sex hormones, and certain corticosteroids such as aldosterone. 18-hydroxycortisol, 18-oxocortisol. Sex hormones varied between males and females. Levels of certain hormones, including cortisol, cortisone, 11-deoxycortisol, 18-hydroxycortisol, 18-oxocortisol, corticosterone, aldosterone, estrone, testosterone, dihydrotestosterone, dehydroepiandrosterone sulfate, 11-ketotestosterone, and 11-hydroxytestosterone, fluctuated with sampling time. Moreover, levels of pregnenolone and progesterone decreased within 1 hour of sampling, with pregnenolone becoming unstable with storage time at 4 degrees after centrifugation, while other hormone levels remained relatively stable for a short period of time without or after centrifugation of the sample. This is the first instance real-world data has been used to assess the pre-analytic stability of plasma hormones and to evaluate the impact of physiological factors on steroid hormones.

3.
Artículo en Inglés | MEDLINE | ID: mdl-38103306

RESUMEN

Steroids are essential in the differential diagnosis of congenital adrenal hyperplasia (CAH) subtypes; however, they may confuse physicians with multifarious results. In this study, we established a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the simultaneous measurement of 24 steroids and developed a steroid metabolite pathway-based report to aid physicians in understanding these results. Solid-phase extraction was used to concentrate and purify target plasma steroids. The linearity, precision, recovery, and matrix effects were thoroughly evaluated. PowerBuilder was used to transfer the results from LC-MS/MS to the graphic report in a laboratory information management system (LIS) and was applied to different subtypes of CAH. Twenty-four steroids were separated and analyzed in one sample preparation and two injections using LC-MS/MS. The linearity of the steroids was excellent, with coefficients of linear regression greater than 0.99. The relative recovery ranged from 90.0 to 107.1 %, whereas the intra- and total coefficient variations were 1.6 âˆ¼ 8.7 % and 2.0 âˆ¼ 9.9 %, respectively. Matrix effects were compensated after internal standard correction. A graphic combination report mode was established and used to effectively identify CAH subtypes. In conclusion, a useful LC-MS/MS method and graphic combination report of 24 steroids based on their metabolite pathways were established.


Asunto(s)
Hiperplasia Suprarrenal Congénita , Espectrometría de Masas en Tándem , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Cromatografía Líquida con Espectrometría de Masas , Esteroides , Hiperplasia Suprarrenal Congénita/diagnóstico
4.
Clin Chim Acta ; 555: 117797, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-38280490

RESUMEN

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) has attracted significant attention in clinical practice owing to its numerous advantages. However, the widespread adoption of this technique is hindered by certain limitations, such as inappropriate analyte selection, low levels of automation, and a lack of specific reference intervals and quality control programs. This review comprehensively summarizes the current challenges associated with LC-MS/MS and proposes potential resolutions. The principle of utility should guide the selection of biomarkers, prioritizing their practical value over sheer quantity. To achieve full-process automation, methodological innovation is crucial for developing high-throughput equipment. Establishing reference intervals for mass spectrometry-based assays across multiple centers and diverse populations is essential for accurate result interpretation. Additionally, the development of commercial quality control materials assumes pivotal importance in ensuring assay reliability and reproducibility. Harmonization and standardization efforts should focus on the development of reference methods and materials for the clinical use of LC-MS/MS. In the future, commercial assay kits and laboratory-developed tests (LDTs) are expected to coexist in clinical laboratories, each offering distinct advantages. The collaborative efforts of diverse professionals is vital for addressing the challenges associated with the clinical application of LC-MS/MS. The anticipated advancements include simplification, increased automation, intelligence, and the standardization of LC-MS/MS, ultimately facilitating its seamless integration into clinical routines for both technicians and clinicians.


Asunto(s)
Laboratorios Clínicos , Espectrometría de Masas en Tándem , Humanos , Cromatografía Liquida/métodos , Espectrometría de Masas en Tándem/métodos , Reproducibilidad de los Resultados , Cromatografía Líquida con Espectrometría de Masas
5.
Clin Chim Acta ; 562: 119846, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38969085

RESUMEN

Proteins are essential components of human cells and tissues, and they are commonly measured in clinical laboratories using immunoassays. However, these assays have certain limitations, such as non-specificity binding, insufficient selectivity, and interference of antibodies. More sensitive, accurate, and efficient technology is required to overcome these limitations. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a powerful analytical tool that provides high sensitivity and specificity, making it superior to traditional methods such as biochemical methods and immunoassays. While LC-MS/MS has been increasingly used for detecting small molecular analytes and steroid hormones in clinical practice recently, its application for protein or peptide analysis is still in its early stages. Established methods for quantifying proteins and peptides by LC-MS/MS are mainly focused on scientific research, and only a few proteins and peptides can be or have the potential to be detected and applied in clinical practice. Therefore, this article aims to review the clinical applications, advantages, and challenges of analyzing proteins and peptides using LC-MS/MS in clinical laboratories.


Asunto(s)
Proteínas , Espectrometría de Masas en Tándem , Espectrometría de Masas en Tándem/métodos , Humanos , Cromatografía Liquida/métodos , Proteínas/análisis , Laboratorios Clínicos
SELECCIÓN DE REFERENCIAS