1.
Invest Radiol ; 57(12): 780-788, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-35640019

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the feasibility and quality of ultra-high-resolution coronary computed tomography angiography (CCTA) with dual-source photon-counting detector CT (PCD-CT) in patients with a high coronary calcium load, including an analysis of the optimal reconstruction kernel and matrix size. MATERIALS AND METHODS: In this institutional review board-approved study, 20 patients (6 women; mean age, 79 ± 10 years; mean body mass index, 25.6 ± 4.3 kg/m 2 ) undergoing PCD-CCTA in the ultra-high-resolution mode were included. Ultra-high-resolution CCTA was acquired in an electrocardiography-gated dual-source spiral mode at a tube voltage of 120 kV and collimation of 120 × 0.2 mm. The field of view (FOV) and matrix sizes were adjusted to the resolution properties of the individual reconstruction kernels using a FOV of 200 × 200 mm 2 or 150 × 150 mm 2 and a matrix size of 512 × 512 pixels or 1024 × 1024 pixels, respectively. Images were reconstructed using vascular kernels of 8 sharpness levels (Bv40, Bv44, Bv56, Bv60, Bv64, Bv72, Bv80, and Bv89), using quantum iterative reconstruction (QIR) at a strength level of 4, and a slice thickness of 0.2 mm. Images with the Bv40 kernel, QIR at a strength level of 4, and a slice thickness of 0.6 mm served as the reference. Image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, and blooming artifacts were quantified. For subjective image quality, 2 blinded readers evaluated image noise and delineation of coronary artery plaques and the adjacent vessel lumen using a 5-point discrete visual scale. A phantom scan served to characterize image noise texture by calculating the noise power spectrum for every reconstruction kernel. RESULTS: Maximum spatial frequency (f peak ) gradually shifted to higher values for reconstructions with the Bv40 to Bv64 kernel (0.15 to 0.56 mm -1 ), but not for reconstructions with the Bv72 to Bv89 kernel. Ultra-high-resolution CCTA was feasible in all patients (median calcium score, 479). In patients, reconstructions with the Bv40 kernel and a slice thickness of 0.6 mm showed largest blooming artifacts (55.2% ± 9.8%) and lowest vessel sharpness (477.1 ± 73.6 ΔHU/mm) while achieving highest SNR (27.4 ± 5.6) and CNR (32.9 ± 6.6) and lowest noise (17.1 ± 2.2 HU). Considering reconstructions with a slice thickness of 0.2 mm, image noise, SNR, CNR, vessel sharpness, and blooming artifacts significantly differed across kernels (all P 's < 0.001). With higher kernel sharpness, SNR and CNR continuously decreased, whereas image noise and vessel sharpness increased, with highest sharpness for the Bv89 kernel (2383.4 ± 787.1 ΔHU/mm). Blooming artifacts continuously decreased for reconstructions with the Bv40 (slice thickness, 0.2 mm; 52.8% ± 9.2%) to the Bv72 kernel (39.7% ± 9.1%). Subjective noise was perceived by both readers in agreement with the objective measurements. Considering delineation of coronary artery plaques and the adjacent vessel lumen, reconstructions with the Bv64 and Bv72 kernel (for both, median score of 5) were favored by the readers providing an excellent anatomic delineation of plaque characteristics and vessel lumen. CONCLUSIONS: Ultra-high-resolution CCTA with PCD-CT is feasible and enables the visualization of calcified coronaries with an excellent image quality, high sharpness, and reduced blooming. Coronary plaque characterization and delineation of the adjacent vessel lumen are possible with an optimal quality using Bv64 kernel, a FOV of 200 × 200 mm 2 , and a matrix size of 512 × 512 pixels.


Asunto(s)
Calcio , Angiografía por Tomografía Computarizada , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Angiografía Coronaria/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos
2.
Eur Radiol ; 20(2): 469-76, 2010 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-19697041

RESUMEN

Besides the assessment of carotid artery stenosis, evaluation of the vascular anatomy and lesions within both the extra- and intracranial arteries is crucial for proper clinical evaluation, treatment choice and planning. The purpose of our study was to evaluate the potential of dual-source CTA and 3T-MRA. In 16 symptomatic CAS patients, contrast-enhanced DSCT and 3T-MRA examinations were performed. For DSCT a dual-energy protocol with a 64 x 0.6-mm collimation was applied. In 3T-MRA intracranial high-resolution unenhanced TOF and extracranial contrast-enhanced MRA were performed. All examinations were analyzed for relevant morphologic and pathologic features or anomalies, and a total of 624 vessel segments were scored. All examinations were of diagnostic image quality with good to excellent vessel visibility. Almost all intracranial arteries were significantly better visualized by MRA compared to CTA (five of six vessels, p < 0.05). DSCT however allowed for further morphological carotid stenosis description, especially with respect to calcification. Although MRA proved to be superior in visualization of smaller intracranial arteries, all pre-interventionally relevant information could be perceived from DSCT. DSCT and MRA may both be regarded as a reliable, fast, pre-interventional imaging investigation in patients with carotid artery stenosis.


Asunto(s)
Estenosis Carotídea/diagnóstico , Angiografía Cerebral/métodos , Angiografía por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Femenino , Humanos , Masculino , Proyectos Piloto , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
3.
Invest Radiol ; 55(9): 556-558, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32701619

RESUMEN

Computed tomography (CT) has evolved over decades, offering superb morphologic imaging with isotropic resolution at rapid acquisition times. The latest developments in hardware, such as photon-counting and ultrahigh-resolution detectors, together with breakthroughs in software technology have further improved spatial and temporal resolution while steadily reducing radiation exposure. These achievements enable CT for functional imaging and make high-quality imaging more accessible through workflow automation. Radiomics, integrated diagnostics, and data science will further push CT applications beyond their current limits.


Asunto(s)
Fotones , Tomografía Computarizada por Rayos X , Programas Informáticos
4.
Am J Cardiol ; 96(6): 747-9, 2005 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-16169351

RESUMEN

Vitamin K antagonists, known as oral anticoagulants, affect the synthesis and function of the matrix Gla protein, which is a potent inhibitor of tissue calcification. We performed multislice spiral computed tomography in 86 patients (53 men, mean age 71 +/- 8 years) with calcific aortic valve disease to quantitate the amount of calcification in the aortic valve and coronary arteries. Patients with long-term oral anticoagulation therapy (mean duration 88 +/- 113 months; n = 23) were compared with those without anticoagulation (n = 63). No differences were found in the demographic, clinical, or echocardiographic characteristics between the 2 study groups. Patients on oral anticoagulant therapy had increased coronary calcium (coronary Agatston score 1,561 +/- 1,141 vs 738 +/- 978, respectively; p = 0.024) and valvular calcium (valvular Agatston score 2,410 +/- 1,759 vs 1,070 +/- 1,085, respectively; p = 0.002) compared with patients without anticoagulation treatment. The results of our study have demonstrated that oral anticoagulation may be associated with increased valvular and coronary calcium in patients with aortic valve disease, presumably due to decreased activation of the matrix Gla protein.


Asunto(s)
Anticoagulantes/efectos adversos , Válvula Aórtica/efectos de los fármacos , Calcinosis/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Administración Oral , Anciano , Anticoagulantes/administración & dosificación , Enfermedad de la Arteria Coronaria/inducido químicamente , Femenino , Enfermedades de las Válvulas Cardíacas/inducido químicamente , Humanos , Masculino , Tomografía Computarizada Espiral , Resultado del Tratamiento , Warfarina/efectos adversos
5.
Int J Cardiol ; 102(2): 195-200, 2005 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-15982484

RESUMEN

BACKGROUND: The aim was to correlate the degree of valvular calcification in patients with aortic stenosis determined by retrospectively electrocardiogram (ECG)-gated multislice spiral computed tomography with stenosis severity assessed by cardiac catheterization. METHODS: Prospective study on 41 patients (18 men, mean age 71+/-8 years) with aortic stenosis, who underwent four detector row multislice spiral computed tomography and cardiac catheterization. Severity of aortic stenosis was classified by cardiac catheterization. Aortic valve area, peak to peak and mean transvalvular gradients were correlated with the degree of calcification determined by multislice spiral computed tomography. Aortic valve calcification was assessed using aortic Agatston score, aortic mass score and aortic volume score. RESULTS: All measured aortic valve calcification scores were significantly higher in patients with severe aortic stenosis (n=29) than in patients with moderate (n=7) or mild aortic stenosis (n=5, p<0.001). Aortic valve calcification scores correlated significantly with aortic valve area (r=-0.49, p=0.001 for aortic mass score) and with peak to peak (r=0.68, p<0.001) and mean (r=0.60, p<0.001) transvalvular gradients. CONCLUSIONS: Severity of aortic valve calcification assessed by cardiac multislice spiral computed tomography is inversely related to aortic valve area and positively correlated with transvalvular gradients. Based on this preliminary data larger studies should be performed with echocardiography as a reference standard in order to validate this new information and its utility in the clinical management of the patient.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Electrocardiografía/métodos , Tomografía Computarizada Espiral , Anciano , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/fisiopatología , Calcinosis/complicaciones , Calcinosis/fisiopatología , Cateterismo Cardíaco , Angiografía Coronaria , Estenosis Coronaria/complicaciones , Estenosis Coronaria/diagnóstico , Femenino , Humanos , Masculino , Estudios Prospectivos , Índice de Severidad de la Enfermedad
6.
Eur Radiol ; 18(7): 1350-5, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18292998

RESUMEN

The purpose was to assess the sensitivity of a CAD software prototype for the detection of pulmonary embolism in MDCT chest examinations with regard to vessel level and to assess the influence on radiologists' detection performance. Forty-three patients with suspected PE were included in this retrospective study. MDCT chest examinations with a standard PE protocol were acquired at a 16-slice MDCT. All patient data were read by three radiologists (R1, R2, R3), and all thrombi were marked. A CAD prototype software was applied to all datasets, and each finding of the software was analyzed with regard to vessel level. The standard of reference was assessed in a consensus read. Sensitivity for the radiologists and CAD software was assessed. Thirty-three patients were positive for PE, with a total of 215 thrombi. The mean overall sensitivity for the CAD software alone was 83% (specificity, 80%). Radiologist sensitivity was 77% = R3, 82% = R2, and R1 = 87%. With the aid of the CAD software, sensitivities increased to 98% (R1), 93% (R2), and 92% (R3) (p<0.0001). CAD performance at the lobar level was 87%, at the segmental 90% and at the subsegmental 77%. With the use of CAD for PE, the detection performance of radiologists can be improved.


Asunto(s)
Competencia Clínica , Embolia Pulmonar/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X/métodos , Medios de Contraste , Femenino , Humanos , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
7.
Radiology ; 241(1): 76-82, 2006 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-16908682

RESUMEN

PURPOSE: To evaluate retrospectively the prevalence and grade of aortic valve calcification incidentally detected on chest multi-detector row computed tomographic (CT) scans and to compare the grade of calcification with the severity of aortic valve disease as assessed with echocardiography. MATERIALS AND METHODS: Patient informed consent was waived by the institutional board on medical ethics that approved this study. The authors identified 402 patients (231 men and 171 women; mean age, 62.5 years +/- 12.1) of 1820 patients who underwent chest multi-detector row CT between July 2001 and August 2004 and also underwent echocardiography. Aortic valve calcification at multi-detector row CT was visually graded on a scale ranging from 0 to 4 (0 = no calcification, 4 = severe calcification). CT findings were correlated with hemodynamic data obtained at echocardiography. Patients without aortic stenosis were compared with patients with aortic stenosis. The Student t test, Spearman correlation coefficient, chi(2) analysis, and an unweighted kappa test were used to compare results. RESULTS: Aortic valve calcification was noted on multi-detector row CT scans in 72 of the 402 patients (18%). Twelve of 20 patients (60%) with grade 3 or grade 4 calcification on CT scans had aortic stenosis at echocardiography, compared with only nine of 382 patients (2.4%) with grade 0-2 calcification (P < .001). Significant correlations were observed between the grade of aortic valve calcification and the echocardiographically determined mean (r = 0.45, P = .03) and peak transvalvular gradient (r = 0.47, P = .03). There was substantial agreement between the grade of valve calcification at multi-detector row CT and the severity of aortic valve disease at echocardiography (kappa = 0.67). CONCLUSION: Aortic valve calcification was an incidental finding on 18% of multi-detector row CT scans. The grade of aortic valve calcification is correlated with the hemodynamic severity of aortic valve disease as determined with echocardiography.


Asunto(s)
Válvula Aórtica/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Calcinosis/epidemiología , Ecocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos
8.
Eur Radiol ; 16(2): 269-75, 2006 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-16075212

RESUMEN

The aims of this study were to optimize image quality for indirect CT venography (sequential versus spiral), and to evaluate different image reconstruction parameters for patients with suspected deep venous thrombosis (DVT). Fifty-one patients (26/25 with/without DVT) were prospectively evaluated for pulmonary embolism (PE) with standard multidetector-row computed tomography (MDCT) protocols. Retrospective image reconstruction was done with different slice thicknesses and reconstruction increments in sequential and spiral modes. All reconstructions were read for depiction of DVT and to evaluate best reconstruction parameters in comparison with the thinnest reconstruction ("gold standard"). Image noise and venous enhancement were measured as objective criteria for image quality. Subjective image quality was rated on a four-point scale. Effective dose was estimated for all reconstructions. In sequential 10/50 reconstruction DVT was completely detected in 13/26 cases, partially in 10/26 cases and was not detected at all in 3/26 cases, and 15/26, 9/26 and 2/26 cases for the 10/20 reconstruction, respectively. DVT was completely detected in all spiral reconstructions. Image noise ranged between 14.8-29.1 HU. Median image quality was 2. Estimated effective dose ranged between 2.3 mSv and 11.8 mSv. Gaps in sequential protocols may lead to false negative results. Therefore, spiral scanning protocols for complete depiction of DVT are mandatory.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Flebografía , Embolia Pulmonar/diagnóstico por imagen , Tomografía Computarizada Espiral , Trombosis de la Vena/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Femenino , Humanos , Aumento de la Imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Sensibilidad y Especificidad , Evaluación de la Tecnología Biomédica
9.
Eur Radiol ; 15(7): 1378-86, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15776240

RESUMEN

The purpose of our animal study was to evaluate a new computed tomography (CT) subtraction technique for visualization of perfusion defects within the lung parenchyma in subsegmental pulmonary embolism (PE). Seven healthy pigs were entered into a prospective trial. Acute PE was artificially induced by fresh clot material prior to the CT scans. Within a single breath-hold, whole thorax CT scans were performed with a 16-slice multidetector-row CT scanner (SOMATOM Sensation 16; Siemens, Forchheim, Germany) before and after intravenous application of 80 ml of contrast medium with a flow rate of 4 ml/s, followed by a saline chaser. The scan parameters were 120 kV and 100 mAs(eff), using a thin collimation of 16x0.75 mm and a table speed/rotation of 15-18 mm (pitch, 1.25-1.5; rotation time, 0.5 s). Axial source images were reconstructed with an effective slice thickness of 1 mm (overlap, 30%). A new automatic subtraction technique was used. After 3D segmentation of the lungs in the plain and contrast-enhanced series, threshold-based extraction of major airways and vascular structures in the contrast images was performed. This segmentation was repeated in the plain CT images segmenting the same number of vessels and airways as in the contrast images. Both scans were registered onto each other using nonrigid registration. After registration both image sets were filtered in a nonlinear fashion excluding segmented airways and vessels. After subtracting the plain CT data from the contrast data the resulting enhancement images were color-encoded and overlaid onto the contrast-enhanced CT angiography (CTA) images. This color-encoded combined display of parenchymal enhancement of the lungs was evaluated interactively on a workstation (Leonardo, Siemens) in axial, coronal and sagittal plane orientations. Axial contrast-enhanced CTA images were rated first, followed by an analysis of the combination images. Finally, CTA images were reread focusing on areas with perfusion deficits indicating PE on the color-coded enhancement display. Subtraction was feasible for all seven studies. In one animal, opacification of the pulmonary arteries was suboptimal owing to heart insufficiency. In the remaining six pigs, a total of 37 perfusion defects were clearly assessable downstream of occluded subsegmental arteries, showing lower or missing enhancement compared with normally perfused lung parenchyma. Indeterminate findings from CTA showed typical PE perfusion defects in four out of six cases on CT subtraction. Additionally, 22 peripheral triangular-shaped enhancement defects were delineated. Nine of these findings were reclassified as definitely being caused by PE on second reading of the CTA data sets. Our initial results have shown that this new subtraction technique for perfusion imaging of PE is feasible, using routine contrast delivery. Dedicated examination protocols are mandatory for adequate opacification of the pulmonary arteries and for optimization of data sets for subsequent subtraction. Perfusion imaging allows a comprehensive assessment of morphology and function, providing more accurate information on acute PE.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Embolia Pulmonar/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Angiografía/métodos , Animales , Medios de Contraste , Modelos Animales de Enfermedad , Estudios de Factibilidad , Imagenología Tridimensional/métodos , Pulmón/irrigación sanguínea , Intensificación de Imagen Radiográfica/métodos , Técnica de Sustracción , Porcinos
10.
Cardiovasc Intervent Radiol ; 28(2): 221-7, 2005.
Artículo en Inglés | MEDLINE | ID: mdl-15883861

RESUMEN

PURPOSE: To evaluate the size and quantity of downstream emboli after thrombectomy using the Arrow-Trerotola Percutaneous Thrombolytic Device (PTD) with or without temporary filtration for extensive iliofemoral and iliocaval thrombi in an in vitro flow model. METHODS: Iliocaval thrombi were simulated by clotted bovine blood in a flow model (semilucent silicone tubings, diameter 12-16 mm). Five experimental set-ups were performed 10 times each; thrombus particles and distribution were measured in the effluent. First, after retrograde insertion, mechanical thrombectomy was performed using the PTD alone. Then a modified self-expanding tulip-shaped temporary vena cava stent filter was inserted additionally at the beginning of each declotting procedure and removed immediately after the intervention without any manipulation within or at the filter itself. In a third step, the filter was filled with thrombus only. Here, two experiments were performed: Careful closure within the flow circuit without any additional fragmentation procedure and running the PTD within the filter lumen, respectively. In the final set-up, mechanical thrombectomy was performed within the thrombus-filled tubing as well as in the filter lumen. The latter was closed at the end of the procedure and both devices were removed from the flow circuit. RESULTS: Running the PTD in the flow circuit without filter protection led to a fragmentation of 67.9% (+/-7.14%) of the clot into particles < or =500 microm; restoration of flow was established in all cases. Additional placement of the filter safely allowed maceration of 82.9% (+/-5.59%) of the thrombus. Controlled closure of the thrombus-filled filter within the flow circuit without additional mechanical treatment broke up 75.2% (+/-10.49%), while additional mechanical thrombectomy by running the PTD within the occluded filter led to dissolution of 90.4% (+/-3.99%) of the initial clot. In the final set-up, an overall fragmentation rate of 99.6% (+/-0.44%) was achieved. CONCLUSIONS: The combined use of the Arrow-Trerotola PTD and a temporary vena cava stent filter proved to be effective for even large clot removal in this experimental set-up.


Asunto(s)
Trombectomía/instrumentación , Filtros de Vena Cava , Trombosis de la Vena/cirugía , Aleaciones , Animales , Cateterismo/instrumentación , Bovinos , Embolia/etiología , Embolia/prevención & control , Diseño de Equipo , Vena Femoral/patología , Vena Ilíaca/patología , Seguridad , Acero Inoxidable , Trombectomía/métodos , Resultado del Tratamiento , Vena Cava Inferior/patología
11.
AJR Am J Roentgenol ; 184(5): 1437-43, 2005 May.
Artículo en Inglés | MEDLINE | ID: mdl-15855093

RESUMEN

OBJECTIVE: The purpose of our study was to develop a simple protocol for reduction of radiation exposure without loss of diagnostic information in chest 16-MDCT. MATERIALS AND METHODS: Two hundred and four patients underwent MDCT of the thorax (Somatom Sensation 16, Siemens). Group 1 was scanned using a standard protocol with 100 mAs(effective) (mAs(eff)). Group 2 was scanned using a dose modulation template (CareDose). Group 3 was scanned with mAs(eff) = body weight (kg). Group 4 was scanned with a combination of weight-adapted mAs(eff) and dose modulation. All other parameters were kept constant. Signal-to-noise ratio was assessed as an objective measurement for image quality, and subjective image quality was rated by three experienced radiologists on a 4-point scale. Effective dose was calculated using dedicated software. RESULTS: The mean noise measurement values were 8.31 H for the 100 mAs(eff) protocol for the regression between weight and signal-to-noise (p < 0.0001), 9.08 H for group 2 (p < 0.0001), 9.0 H for group 3 (p = 0.5051), and 9.98 H for group 4 (p = 0.0152). The median image quality was 1 (1 = highest quality) in all subgroups. The mean effective dose was 6.83 mSv, 5.92 mSv, 4.73 mSv, and 3.97 mSv, respectively. The least correlation between weight and image noise was achieved for the individually weight-adapted protocol and in the weight-adapted with CareDose combination. CONCLUSION: By tube current time product adaptation (kg = mAs(eff)) combined with an online tube current modulation template, a well-balanced examination without significant loss of information was achieved for this specific scanner. Thus, individually adapted protocols for chest 16-MDCT can be recommended.


Asunto(s)
Protección Radiológica/métodos , Tomografía Computarizada por Rayos X , Algoritmos , Análisis de Varianza , Índice de Masa Corporal , Peso Corporal , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosis de Radiación , Radiografía Torácica , Análisis de Regresión
12.
Int J Cardiovasc Imaging ; 19(4): 349-53, 2003 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-14598905

RESUMEN

This case report describes the use of retrospectively ECG-gated multislice spiral computed tomography (MSCT) for evaluation of lesion severity in a patient with relevant left main stenosis by visual analysis of the coronary angiogram. For further diagnostic evaluation the patient underwent intravascular ultrasound (IVUS) imaging, which showed a maximal 30% area stenosis, and MSCT, which demonstrated a maximal 48% area stenosis. MSCT was useful in this case to defer cardiac surgery and might be used as a noninvasive alternative to IVUS imaging in case of doubtful lesion severity.


Asunto(s)
Estenosis Coronaria/diagnóstico por imagen , Electrocardiografía , Tomografía Computarizada Espiral , Anciano , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Humanos , Masculino , Ultrasonografía Intervencional
13.
AJR Am J Roentgenol ; 183(6): 1813-8, 2004 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-15547235

RESUMEN

OBJECTIVE: The degree of valvular calcification in patients with aortic stenosis was determined with retrospectively ECG-gated 16-MDCT and correlated with the severity of stenosis assessed at cardiac catheterization. SUBJECTS AND METHODS: We conducted a prospective study of 72 patients (38 men and 34 women; mean age +/- SD, 69.5 +/- 8.8 years) with aortic stenosis who underwent 16-MDCT and cardiac catheterization. Aortic valve calcification was assessed using the aortic Agatston score, aortic mass score, and aortic volume score. Severity of aortic stenosis was classified at cardiac catheterization. Aortic valve area and peak-to-peak and mean transvalvular gradients were correlated with the degree of calcification determined on MDCT. RESULTS: All measured aortic valve calcification scores were significantly higher in patients with severe aortic stenosis (n = 46) than in patients with moderate (n = 15) or mild (n = 11, p < 0.001) aortic stenosis. Aortic valve calcification scores were inversely related to aortic valve area (r = -0.67, p < 0.001 for aortic mass score) and correlated significantly with peak-to-peak (r = 0.70, p < 0.001) and mean transvalvular (r = 0.72, p < 0.001) gradients. No correlation between the aortic valve calcification and the total coronary calcium scores was observed. CONCLUSION: Aortic valve calcification assessed on 16-MDCT is associated with severity of aortic stenosis. Thus, aortic valve calcification scores should be calculated routinely in all patients undergoing MDCT for assessment of coronary calcification. High aortic valve calcification scores indicate possibly severe aortic stenosis and should prompt a further functional evaluation.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos X/métodos , Anciano , Estenosis de la Válvula Aórtica/patología , Calcinosis/patología , Cateterismo Cardíaco , Distribución de Chi-Cuadrado , Femenino , Humanos , Masculino , Estudios Prospectivos , Reproducibilidad de los Resultados
14.
Lancet ; 361(9360): 827-33, 2003 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-12642050

RESUMEN

BACKGROUND: Vascular calcification is the most prominent underlying pathological finding in patients with uraemia, and is a predictor of mortality in this population. Fetuin-A (alpha2-Heremans Schmid glycoprotein; AHSG) is an important circulating inhibitor of calcification in vivo, and is downregulated during the acute-phase response. We aimed to investigate the hypothesis that AHSG deficiency is directly related to uraemic vascular calcification. METHODS: We did a cross-sectional study in 312 stable patients on haemodialysis to analyse the inter-relation of AHSG and C-reactive protein (CRP) and their predictive effect on all-cause and cardiovascular mortality, over a period of 32 months. Subsequently, we tested the capacity of serum to inhibit CaxPO4 precipitation in patients on long-term dialysis (n=17) with apparent soft-tissue calcifications, and in those on short-term dialysis (n=8) without evidence of calcifications and cardiovascular disease. FINDINGS: AHSG concentrations in serum were significantly lower in patients on haemodialysis (mean 0.66 g/L [SD 0.28]) than in healthy controls (0.72 [0.19]). Low concentrations of the glycoprotein were associated with raised amounts of CRP and with enhanced cardiovascular (p=0.031) and all-cause mortality (p=0.0013). Sera from patients on long-term dialysis with low AHSG concentrations showed impaired ex-vivo capacity to inhibit CaxPO4 precipitation (mean IC50: 9.0 microL serum [SD 3.1] vs 7.5 [0.8] in short-term patients and 6.4 [2.6] in controls). Reconstitution of sera with purified AHSG returned this impairment to normal. Interpretation AHSG deficiency is associated with inflammation and links vascular calcification to mortality in patients on dialysis. Activated acute-phase response and AHSG deficiency might account for accelerated atherosclerosis in uraemia.


Asunto(s)
Proteínas Sanguíneas/deficiencia , Enfermedades Cardiovasculares/mortalidad , Diálisis Renal , Proteínas Sanguíneas/metabolismo , Calcinosis/etiología , Enfermedades Cardiovasculares/sangre , Estudios de Casos y Controles , Estudios Transversales , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , alfa-2-Glicoproteína-HS