RESUMEN
BACKGROUND/OBJECTIVES: The practice of palliative radiation therapy (RT) is based on extrapolation from adult literature. We evaluated patterns of pediatric palliative RT to describe regimens used to identify opportunity for future pediatric-specific clinical trials. DESIGN/METHODS: Six international institutions with pediatric expertise completed a 122-item survey evaluating patterns of palliative RT for patients ≤21 years old from 2010 to 2015. Two institutions use proton RT. Palliative RT was defined as treatment with the goal of symptom control or prevention of immediate life-threatening progression. RESULTS: Of 3,225 pediatric patients, 365 (11%) were treated with palliative intent to a total of 427 disease sites. Anesthesia was required in 10% of patients. Treatment was delivered to metastatic disease in 54% of patients. Histologies included neuroblastoma (30%), osteosarcoma (18%), leukemia/lymphoma (12%), rhabdomyosarcoma (12%), medulloblastoma/ependymoma (12%), Ewing sarcoma (8%), and other (8%). Indications included pain (43%), intracranial symptoms (23%), respiratory compromise (14%), cord compression (8%), and abdominal distention (6%). Sites included nonspine bone (35%), brain (16% primary tumors, 6% metastases), abdomen/pelvis (15%), spine (12%), head/neck (9%), and lung/mediastinum (5%). Re-irradiation comprised 16% of cases. Techniques employed three-dimensional conformal RT (41%), intensity-modulated RT (23%), conventional RT (26%), stereotactic body RT (6%), protons (1%), electrons (1%), and other (2%). The most common physician-reported barrier to consideration of palliative RT was the concern about treatment toxicity (83%). CONCLUSION: There is significant diversity of practice in pediatric palliative RT. Combined with ongoing research characterizing treatment response and toxicity, these data will inform the design of forthcoming clinical trials to establish effective regimens and minimize treatment toxicity for this patient population.
Asunto(s)
Neoplasias/radioterapia , Cuidados Paliativos , Pautas de la Práctica en Medicina/normas , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Adolescente , Adulto , Niño , Preescolar , Femenino , Estudios de Seguimiento , Humanos , Lactante , Recién Nacido , Agencias Internacionales , Masculino , Estadificación de Neoplasias , Neoplasias/patología , Pronóstico , Dosificación Radioterapéutica , Adulto JovenRESUMEN
Objective.To experimentally validate two online adaptive proton therapy (APT) workflows using Gafchromic EBT3 films and optically stimulated luminescent dosimeters (OSLDs) in an anthropomorphic head-and-neck phantom.Approach.A three-field proton plan was optimized on the planning CT of the head-and-neck phantom with 2.0 Gy(RBE) per fraction prescribed to the clinical target volume. Four fractions were simulated by varying the internal anatomy of the phantom. Three distinct methods were delivered: daily APT researched by the Paul Scherrer Institute (DAPTPSI), online adaptation researched by the Massachusetts General Hospital (OAMGH), and a non-adaptive (NA) workflow. All methods were implemented and measured at PSI. DAPTPSIperformed full online replanning based on analytical dose calculation, optimizing to the same objectives as the initial treatment plan. OAMGHperformed Monte-Carlo-based online plan adaptation by only changing the fluences of a subset of proton beamlets, mimicking the planned dose distribution. NA delivered the initial plan with a couch-shift correction based on in-room imaging. For all 12 deliveries, two films and two sets of OSLDs were placed at different locations in the phantom.Main results.Both adaptive methods showed improved dosimetric results compared to NA. For film measurements in the presence of anatomical variations, the [min-max] gamma pass rates (3%/3 mm) between measured and clinically approved doses were [91.5%-96.1%], [94.0%-95.8%], and [67.2%-93.1%] for DAPTPSI, OAMGH, and NA, respectively. The OSLDs confirmed the dose calculations in terms of absolute dosimetry. Between the two adaptive workflows, OAMGHshowed improved target coverage, while DAPTPSIshowed improved normal tissue sparing, particularly relevant for the brainstem.Significance.This is the first multi-institutional study to experimentally validate two different concepts with respect to online APT workflows. It highlights their respective dosimetric advantages, particularly in managing interfractional variations in patient anatomy that cannot be addressed by non-adaptive methods, such as internal anatomy changes.
Asunto(s)
Fantasmas de Imagen , Terapia de Protones , Planificación de la Radioterapia Asistida por Computador , Flujo de Trabajo , Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Humanos , Dosificación Radioterapéutica , Método de Montecarlo , RadiometríaRESUMEN
Purpose: This work evaluates an online adaptive (OA) workflow for head-and-neck (H&N) intensity-modulated proton therapy (IMPT) and compares it with full offline replanning (FOR) in patients with large anatomical changes. Methods: IMPT treatment plans are created retrospectively for a cohort of eight H&N cancer patients that previously required replanning during the course of treatment due to large anatomical changes. Daily cone-beam CTs (CBCT) are acquired and corrected for scatter, resulting in 253 analyzed fractions. To simulate the FOR workflow, nominal plans are created on the planning-CT and delivered until a repeated-CT is acquired; at this point, a new plan is created on the repeated-CT. To simulate the OA workflow, nominal plans are created on the planning-CT and adapted at each fraction using a simple beamlet weight-tuning technique. Dose distributions are calculated on the CBCTs with Monte Carlo for both delivery methods. The total treatment dose is accumulated on the planning-CT. Results: Daily OA improved target coverage compared to FOR despite using smaller target margins. In the high-risk CTV, the median D98 degradation was 1.1 % and 2.1 % for OA and FOR, respectively. In the low-risk CTV, the same metrics yield 1.3 % and 5.2 % for OA and FOR, respectively. Smaller setup margins of OA reduced the dose to all OARs, which was most relevant for the parotid glands. Conclusion: Daily OA can maintain prescription doses and constraints over the course of fractionated treatment, even in cases of large anatomical changes, reducing the necessity for manual replanning in H&N IMPT.
RESUMEN
Purpose: To demonstrate the suitability of optically stimulated luminescence detectors (OSLDs) for accurate simultaneous measurement of the absolute point dose and dose-weighted linear energy transfer (LETD) in an anthropomorphic phantom for experimental validation of daily adaptive proton therapy. Methods: A clinically realistic intensity-modulated proton therapy (IMPT) treatment plan was created based on a CT of an anthropomorphic head-and-neck phantom made of tissue-equivalent material. The IMPT plan was optimized with three fields to deliver a uniform dose to the target volume covering the OSLDs. Different scenarios representing inter-fractional anatomical changes were created by modifying the phantom. An online adaptive proton therapy workflow was used to recover the daily dose distribution and account for the applied geometry changes. To validate the adaptive workflow, measurements were performed by irradiating Al2O3:C OSLDs inside the phantom. In addition to the measurements, retrospective Monte Carlo simulations were performed to compare the absolute dose and dose-averaged LET (LETD) delivered to the OSLDs. Results: The online adaptive proton therapy workflow was shown to recover significant degradation in dose conformity resulting from large anatomical and positioning deviations from the reference plan. The Monte Carlo simulations were in close agreement with the OSLD measurements, with an average relative error of 1.4% for doses and 3.2% for LETD. The use of OSLDs for LET determination allowed for a correction for the ionization quenched response. Conclusion: The OSLDs appear to be an excellent detector for simultaneously assessing dose and LET distributions in proton irradiation of an anthropomorphic phantom. The OSLDs can be cut to almost any size and shape, making them ideal for in-phantom measurements to probe the radiation quality and dose in a predefined region of interest. Although we have presented the results obtained in the experimental validation of an adaptive proton therapy workflow, the same approach can be generalized and used for a variety of clinical innovations and workflow developments that require accurate assessment of point dose and/or average LET.
RESUMEN
PURPOSE: To evaluate the suitability of low-dose CT protocols for online plan adaptation of head-and-neck patients. METHODS: We acquired CT scans of a head phantom with protocols corresponding to CT dose index volume CTDIvol in the range of 4.2-165.9 mGy. The highest value corresponds to the standard protocol used for CT simulations of 10 head-and-neck patients included in the study. The minimum value corresponds to the lowest achievable tube current of the GE Discovery RT scanner used for the study. For each patient and each low-dose protocol, the noise relative to the standard protocol, derived from phantom images, was applied to a virtual CT (vCT). The vCT was obtained from a daily CBCT scan corresponding to the fraction with the largest anatomical changes. We ran an established adaptive workflow twice for each low-dose protocol using a high-quality daily vCT and the corresponding low-dose synthetic vCT. For a relative comparison of the adaptation efficacy, two adapted plans were recalculated in the high-quality vCT and evaluated with the contours obtained through deformable registration of the planning CT. We also evaluated the accuracy of dose calculation in low-dose CT volumes using the standard CT protocol as reference. RESULTS: The maximum differences in D98 between low-dose protocols and the standard protocol for the high-risk and low-risk CTV were found to be 0.6% and 0.3%, respectively. The difference in OAR sparing was up to 3%. The Dice similarity coefficient between propagated contours obtained with low-dose and standard protocols was above 0.982. The mean 2%/2 mm gamma pass rate for the lowest-dose image, using the standard protocol as reference, was found to be 99.99%. CONCLUSION: The differences between low-dose protocols and the standard scanning protocol were marginal. Thus, low-dose CT protocols are suitable for online adaptive proton therapy of head-and-neck cancers. As such, considering scanning protocols used in our clinic, the imaging dose associated with online adaption of head-and-neck cancers treated with protons can be reduced by a factor of 40.
RESUMEN
PURPOSE: To compare the efficacy of CT-on-rails versus in-room CBCT for daily adaptive proton therapy. METHODS: We analyzed a cohort of ten head-and-neck patients with daily CBCT and corresponding virtual CT images. The necessity of moving the patient after a CT scan is the most significant difference in the adaptation workflow, leading to an increased treatment execution uncertainty σ. It is a combination of the isocenter-matching σi and random patient movements induced by the couch motion σm. The former is assumed to never exceed 1 mm. For the latter, we studied three different scenarios with σm = 1, 2, and 3 mm. Accordingly, to mimic the adaptation workflow with CT-on-rails, we introduced random offsets after Monte-Carlo-based adaptation but before delivery of the adapted plan. RESULTS: There were no significant differences in accumulated dose-volume histograms and dose distributions for σm = 1 and 2 mm. Offsets with σm = 3 mm resulted in underdosage to CTV and hot spots of considerable volume. CONCLUSION: Since σm typically does not exceed 2 mm for in-room CT, there is no clinically significant dosimetric difference between the two modalities for online adaptive therapy of head-and-neck patients. Therefore, in-room CT-on-rails can be considered a good alternative to CBCT for adaptive proton therapy.
RESUMEN
The high conformality of intensity-modulated proton therapy (IMPT) dose distributions causes treatment plans to be sensitive to geometrical changes during the course of a fractionated treatment. This can be addressed using adaptive proton therapy (APT). One important question in APT is the frequency of adaptations performed during a fractionated treatment, which is related to the question whether plan adaptation has to be done online or offline. The purpose of this work is to investigate the impact of weekly and daily online IMPT plan adaptation on the treatment quality for head and neck patients. A cohort of ten head and neck patients with daily acquired cone-beam CT (CBCT) images was evaluated retrospectively. Dose tracking of the IMPT treatment was performed for three scenarios: base plan with no adaptation (BP), weekly online adaptation (OAW), and daily online adaptation (OAD). Both adaptation schemes used an in-house developed online APT workflow, performing Monte Carlo dose calculations on scatter-corrected CBCTs. IMPT plan adaptation was achieved by only tuning the weights of a subset of beamlets, based on deformable image registration from the planning CT to each CBCT. Although OADmitigated random delivery errors more effectively than OAWon a fraction per fraction basis, both OAWand OADachieved the clinical goals for all ten patients, while BP failed for six cases. In the high-risk CTV, accumulated values ofD98%ranged between 97.15% and 99.73% of the prescription dose for OAD, with a median of 98.07%. For OAW, values between 95.02% and 99.26% were obtained, with a median of 97.61% of the prescription dose. Otherwise, the dose to most organs at risk was similar for all three scenarios. Globally, our results suggest that OAWcould be used as an alternative approach to OADfor most patients in order to reduce the clinical workload.
Asunto(s)
Neoplasias de Cabeza y Cuello , Terapia de Protones , Radioterapia de Intensidad Modulada , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Órganos en Riesgo , Terapia de Protones/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/métodos , Estudios RetrospectivosRESUMEN
BACKGROUND: Lower-dose cone-beam computed tomography protocols for image-guided radiotherapy may permit target localization while minimizing radiation exposure. We prospectively evaluated a lower-dose cone-beam protocol for central nervous system image-guided radiotherapy across a multinational pediatrics consortium. METHODS: Seven institutions prospectively employed a lower-dose cone-beam computed tomography central nervous system protocol (weighted average dose 0.7 mGy) for patients ≤21 years. Treatment table shifts between setup with surface lasers versus cone-beam computed tomography were used to approximate setup accuracy, and vector magnitudes for these shifts were calculated. Setup group mean, interpatient, interinstitution, and random error were estimated, and clinical factors were compared by mixed linear modeling. RESULTS: Among 96 patients, with 2179 pretreatment cone-beam computed tomography acquisitions, median age was 9 years (1-20). Setup parameters were 3.13, 3.02, 1.64, and 1.48 mm for vector magnitude group mean, interpatient, interinstitution, and random error, respectively. On multivariable analysis, there were no significant differences in mean vector magnitude by age, gender, performance status, target location, extent of resection, chemotherapy, or steroid or anesthesia use. Providers rated >99% of images as adequate or better for target localization. CONCLUSIONS: A lower-dose cone-beam computed tomography protocol demonstrated table shift vector magnitude that approximate clinical target volume/planning target volume expansions used in central nervous system radiotherapy. There were no significant clinical predictors of setup accuracy identified, supporting use of this lower-dose cone-beam computed tomography protocol across a diverse pediatric population with brain tumors.
Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Errores de Configuración en Radioterapia/prevención & control , Adolescente , Adulto , Neoplasias Encefálicas/patología , Niño , Preescolar , Tomografía Computarizada de Haz Cónico/métodos , Femenino , Humanos , Lactante , Cooperación Internacional , Masculino , Pediatría/métodos , Estudios Prospectivos , Dosificación Radioterapéutica , Radioterapia Guiada por Imagen/métodos , Adulto JovenRESUMEN
BACKGROUND: Stereotactic body radiotherapy (SBRT) of the spine provides superior tumor control, but vertebral compression fractures are increased and the pathophysiological process underneath is not well understood. Data on histopathological changes, particularly after salvage SBRT (sSBRT) following conventional irradiation, are scarce. OBJECTIVE: To investigate surgical specimens after sSBRT and primary SBRT (pSBRT) regarding histopathological changes. METHODS: We assessed 704 patients treated with spine SBRT 2006 to 2012. Thirty patients underwent salvage surgery; 23 histopathological reports were available. Clinical and histopathological findings were analyzed for sSBRT (69.6%) and pSBRT (30.4%). RESULTS: Mean time to surgery after sSBRT/pSBRT was 8.3/10.3 mo (P = .64). Reason for surgery included pain (sSBRT/pSBRT: 12.5%/71.4%, P = .25), fractures (sSBRT/pSBRT: 37.5%/28.6%, P = .68), and neurological symptoms (sSBRT/pSBRT: 68.8%/42.9%, P = .24). Radiological tumor progression after sSBRT/pSBRT was seen in 71.4%/42.9% (P = .2). Most specimens displayed viable/proliferative tumor (sSBRT/pSBRT: 62.5%/71.4%, P = .68 and 56.3%/57.1%, P = .97). Few specimens showed soft tissue necrosis (sSBRT/pSBRT: 20%/28.6%, P = .66), osteonecrosis (sSBRT/pSBRT: 14.3%/16.7%, P = .89), or bone marrow fibrosis (sSBRT/pSBRT: 42.9%/33.3%, P = .69). Tumor bed necrosis was more common after sSBRT (81.3%/42.9%, P = .066). Radiological tumor progression correlated with viable/proliferative tumor (P = .03/P = .006) and tumor bed necrosis (P = .03). Fractures were increased with bone marrow fibrosis (P = .07), but not with osteonecrosis (P = .53) or soft tissue necrosis (P = .19). Neurological symptoms were common with radiological tumor progression (P = .07), but not with fractures (P = .18). CONCLUSION: For both, sSBRT and pSBRT, histopathological changes were similar. Neurological symptoms were attributable to tumor progression and pathological fractures were not associated with osteonecrosis or tumor progression.
Asunto(s)
Radiocirugia/efectos adversos , Reirradiación/efectos adversos , Terapia Recuperativa/efectos adversos , Neoplasias de la Columna Vertebral/radioterapia , Adulto , Anciano , Estudios de Cohortes , Femenino , Fracturas por Compresión/epidemiología , Fracturas por Compresión/etiología , Humanos , Masculino , Persona de Mediana Edad , Necrosis/epidemiología , Necrosis/etiología , Traumatismos por Radiación/epidemiología , Traumatismos por Radiación/etiología , Radiocirugia/métodos , Reirradiación/métodos , Terapia Recuperativa/métodos , Fracturas de la Columna Vertebral/epidemiología , Fracturas de la Columna Vertebral/etiología , Neoplasias de la Columna Vertebral/secundarioRESUMEN
PURPOSE: To predict the organ at risk (OAR) dose levels achievable with proton beam therapy (PBT), solely based on the geometric arrangement of the target volume in relation to the OARs. A comparison with an alternative therapy yields a prediction of the patient-specific benefits offered by PBT. This could enable physicians at hospitals without proton capabilities to make a better-informed referral decision or aid patient selection in model-based clinical trials. METHODS AND MATERIALS: Skull-base tumors were chosen to test the method, owing to their geometric complexity and multitude of nearby OARs. By exploiting the correlations between the dose and distance-to-target in existing PBT plans, the models were independently trained for 6 types of OARs: brainstem, cochlea, optic chiasm, optic nerve, parotid gland, and spinal cord. Once trained, the models could estimate the feasible dose-volume histogram and generalized equivalent uniform dose (gEUD) for OAR structures of new patients. The models were trained using 20 patients and validated using an additional 21 patients. Validation was achieved by comparing the predicted gEUD to that of the actual PBT plan. RESULTS: The predicted and planned gEUD were in good agreement. Considering all OARs, the prediction error was +1.4 ± 5.1 Gy (mean ± standard deviation), and Pearson's correlation coefficient was 93%. By comparing with an intensity modulated photon treatment plan, the model could classify whether an OAR structure would experience a gain, with a sensitivity of 93% (95% confidence interval: 87%-97%) and specificity of 63% (95% confidence interval: 38%-84%). CONCLUSIONS: We trained and validated models that could quickly and accurately predict the patient-specific benefits of PBT for skull-base tumors. Similar models could be developed for other tumor sites. Such models will be useful when an estimation of the feasible benefits of PBT is desired but the experience and/or resources required for treatment planning are unavailable.
Asunto(s)
Modelos Biológicos , Atención Dirigida al Paciente/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de la Base del Cráneo/diagnóstico , Neoplasias de la Base del Cráneo/radioterapia , Simulación por Computador , Relación Dosis-Respuesta en la Radiación , Humanos , Bases del Conocimiento , Aprendizaje Automático , Pronóstico , Dosificación Radioterapéutica , Reproducibilidad de los Resultados , Sensibilidad y EspecificidadRESUMEN
PURPOSE: Reirradiation has been proposed as an effective modality for recurrent central nervous system (CNS) malignancies in adults. We evaluated the toxicity and outcomes of CNS reirradiation in pediatric patients. METHODS AND MATERIALS: The data from pediatric patients <21 years of age at the initial diagnosis who developed a recurrent CNS malignancy that received repeat radiation therapy (RT) across 5 facilities in an international pediatric research consortium were retrospectively reviewed. RESULTS: Sixty-seven pediatric patients underwent CNS reirradiation. The primary diagnoses included medulloblastoma/primitive neuroectodermal tumor (n=20; 30%), ependymoma (n=19; 28%), germ cell tumor (n=8; 12%), high-grade glioma (n=9; 13%), low-grade glioma (n=5; 7%), and other (n=6; 9%). The median age at the first course of RT was 8.5 years (range 0.5-19.5) and was 12.3 years (range 3.3-30.2) at reirradiation. The median interval between RT courses was 2.0 years (range 0.3-16.5). The median radiation dose and fractionation in equivalent 2-Gy fractions was 63.7 Gy (range 27.6-74.8) for initial RT and 53.1 Gy (range 18.6-70.1) for repeat RT. The relapse location was infield in 52 patients (78%) and surrounding the initial RT field in 15 patients (22%). Thirty-seven patients (58%) underwent gross or subtotal resection at recurrence. The techniques used for reirradiation were intensity modulated RT (n=46), 3-dimensional conformal RT (n=9), stereotactic radiosurgery (n=4; 12-13 Gy × 1 or 5 Gy × 5), protons (n=4), combined modality (n=3), 2-dimensional RT (n=1), and brachytherapy (n=1). Radiation necrosis was detected in 2 patients after the first RT course and 1 additional patient after reirradiation. Six patients (9%) developed secondary neoplasms after initial RT (1 hematologic, 5 intracranial). One patient developed a secondary neoplasm identified shortly after repeat RT. The median overall survival after completion of repeat RT was 12.8 months for the entire cohort and 20.5 and 8.4 months for patients with recurrent ependymoma and medulloblastoma after reirradiation, respectively. CONCLUSIONS: CNS reirradiation in pediatric patients could be a reasonable treatment option, with moderate survival noted after repeat RT. However, prospective data characterizing the rates of local control and toxicity are needed.
Asunto(s)
Neoplasias del Sistema Nervioso Central/radioterapia , Recurrencia Local de Neoplasia/radioterapia , Reirradiación/métodos , Adolescente , Adulto , Niño , Preescolar , Fraccionamiento de la Dosis de Radiación , Ependimoma/radioterapia , Femenino , Glioma/radioterapia , Humanos , Lactante , Masculino , Meduloblastoma/radioterapia , Reirradiación/efectos adversos , Adulto JovenRESUMEN
Ultrasound-induced blood stasis has been observed for more than 30 years. Most of the literature has been focused on the health risks associated with this phenomenon and methods employed to prevent stasis from occurring during ultrasound imaging. To date, experimental observations have been either in vitro or invasive. The current work demonstrates ultrasound-induced blood stasis in murine normal leg muscle versus tumor-bearing legs, observed through noninvasive measurements of optical spectroscopy, and discusses possible diagnostic uses for this previously undesirable effect of ultrasound. We demonstrate that, using optical spectroscopy, effects of ultrasound can be used to differentiate tumor from normal leg muscle tissue in mice. Finally, we propose a novel diagnostic algorithm that quantitatively differentiates tumor from nontumor with maximum specificity 0.83, maximum sensitivity 0.79, and area under receiver-operating-characteristics curve 0.90.
Asunto(s)
Hemostasis/efectos de la radiación , Neoplasias/diagnóstico , Óptica y Fotónica , Análisis Espectral/métodos , Ultrasonido , Animales , Diagnóstico Diferencial , Modelos Animales de Enfermedad , Femenino , Miembro Posterior/irrigación sanguínea , Miembro Posterior/patología , Miembro Posterior/efectos de la radiación , Ratones , Músculos/irrigación sanguínea , Músculos/patología , Músculos/efectos de la radiación , Neoplasias/irrigación sanguínea , Neoplasias/patología , Análisis Espectral/instrumentación , Factores de TiempoRESUMEN
PURPOSE: This work aims at investigating intensity corrected cone-beam x-ray computed tomography (CBCT) images for accurate dose calculation in adaptive intensity modulated proton therapy (IMPT) for prostate and head and neck (H&N) cancer. A deformable image registration (DIR)-based method and a scatter correction approach using the image data obtained from DIR as prior are characterized and compared on the basis of the same clinical patient cohort for the first time. METHODS: Planning CT (pCT) and daily CBCT data (reconstructed images and measured projections) of four H&N and four prostate cancer patients have been considered in this study. A previously validated Morphons algorithm was used for DIR of the planning CT to the current CBCT image, yielding a so-called virtual CT (vCT). For the first time, this approach was translated from H&N to prostate cancer cases in the scope of proton therapy. The warped pCT images were also used as prior for scatter correction of the CBCT projections for both tumor sites. Single field uniform dose and IMPT (only for H&N cases) treatment plans have been generated with a research version of a commercial planning system. Dose calculations on vCT and scatter corrected CBCT (CBCTcor) were compared by means of the proton range and a gamma-index analysis. For the H&N cases, an additional diagnostic replanning CT (rpCT) acquired within three days of the CBCT served as additional reference. For the prostate patients, a comprehensive contour comparison of CBCT and vCT, using a trained physician's delineation, was performed. RESULTS: A high agreement of vCT and CBCTcor was found in terms of the proton range and gamma-index analysis. For all patients and indications between 95% and 100% of the proton dose profiles in beam's eye view showed a range agreement of better than 3 mm. The pass rate in a (2%,2 mm) gamma-comparison was between 96% and 100%. For H&N patients, an equivalent agreement of vCT and CBCTcor to the reference rpCT was observed. However, for the prostate cases, an insufficient accuracy of the vCT contours retrieved from DIR was found, while the CBCTcor contours showed very high agreement to the contours delineated on the raw CBCT. CONCLUSIONS: For H&N patients, no considerable differences of vCT and CBCTcor were found. For prostate cases, despite the high dosimetric agreement, the DIR yields incorrect contours, probably due to the more pronounced anatomical changes in the abdomen and the reduced soft-tissue contrast in the CBCT. Using the vCT as prior, these inaccuracies can be overcome and images suitable for accurate delineation and dose calculation in CBCT-based adaptive IMPT can be retrieved from scatter correction of the CBCT projections.
Asunto(s)
Tomografía Computarizada de Haz Cónico , Procesamiento de Imagen Asistido por Computador , Dosis de Radiación , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia Guiada por Imagen , Radioterapia de Intensidad Modulada , Dispersión de Radiación , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Masculino , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Dosificación RadioterapéuticaRESUMEN
PURPOSE: To demonstrate the feasibility of proton dose calculation on scatter-corrected cone-beam computed tomographic (CBCT) images for the purpose of adaptive proton therapy. METHODS: CBCT projection images were acquired from anthropomorphic phantoms and a prostate patient using an on-board imaging system of an Elekta infinity linear accelerator. Two previously introduced techniques were used to correct the scattered x-rays in the raw projection images: uniform scatter correction (CBCTus) and a priori CT-based scatter correction (CBCTap). CBCT images were reconstructed using a standard FDK algorithm and GPU-based reconstruction toolkit. Soft tissue ROI-based HU shifting was used to improve HU accuracy of the uncorrected CBCT images and CBCTus, while no HU change was applied to the CBCTap. The degree of equivalence of the corrected CBCT images with respect to the reference CT image (CTref) was evaluated by using angular profiles of water equivalent path length (WEPL) and passively scattered proton treatment plans. The CBCTap was further evaluated in more realistic scenarios such as rectal filling and weight loss to assess the effect of mismatched prior information on the corrected images. RESULTS: The uncorrected CBCT and CBCTus images demonstrated substantial WEPL discrepancies (7.3 ± 5.3 mm and 11.1 ± 6.6 mm, respectively) with respect to the CTref, while the CBCTap images showed substantially reduced WEPL errors (2.4 ± 2.0 mm). Similarly, the CBCTap-based treatment plans demonstrated a high pass rate (96.0% ± 2.5% in 2 mm/2% criteria) in a 3D gamma analysis. CONCLUSIONS: A priori CT-based scatter correction technique was shown to be promising for adaptive proton therapy, as it achieved equivalent proton dose distributions and water equivalent path lengths compared to those of a reference CT in a selection of anthropomorphic phantoms.
Asunto(s)
Tomografía Computarizada de Haz Cónico/métodos , Terapia de Protones/métodos , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Algoritmos , Tomografía Computarizada de Haz Cónico/instrumentación , Estudios de Factibilidad , Humanos , Masculino , Modelos Biológicos , Fantasmas de Imagen , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Terapia de Protones/instrumentación , Protones , Dosificación Radioterapéutica , Dispersión de Radiación , Agua , Rayos XRESUMEN
PURPOSE: To evaluate plan quality and delivery efficiency gains of volumetric modulated arc therapy (VMAT) versus a multicriteria optimization-based intensity modulated radiation therapy (MCO-IMRT) for stereotactic radiosurgery of spinal metastases. METHODS AND MATERIALS: MCO-IMRT plans (RayStation V2.5; RaySearch Laboratories, Stockholm, Sweden) of 10 spinal radiosurgery cases using 7-9 beams were developed for clinical delivery, and patients were replanned using VMAT with partial arcs. The prescribed dose was 18 Gy, and target coverage was maximized such that the maximum dose to the planning organ-at-risk volume (PRV) of the spinal cord was 10 or 12 Gy. Dose-volume histogram (DVH) constraints from the clinically acceptable MCO-IMRT plans were utilized for VMAT optimization. Plan quality and delivery efficiency with and without collimator rotation for MCO-IMRT and VMAT were compared and analyzed based upon DVH, planning target volume coverage, homogeneity index, conformity number, cord PRV sparing, total monitor units (MU), and delivery time. RESULTS: The VMAT plans were capable of matching most DVH constraints from the MCO-IMRT plans. The ranges of MU were 4808-7193 for MCO-IMRT without collimator rotation, 3509-5907 for MCO-IMRT with collimator rotation, 4444-7309 for VMAT without collimator rotation, and 3277-5643 for VMAT with collimator of 90 degrees. The MU for the VMAT plans were similar to their corresponding MCO-IMRT plans, depending upon the complexity of the target and PRV geometries, but had a larger range. The delivery times of the MCO-IMRT and VMAT plans, both with collimator rotation, were 18.3 ± 2.5 minutes and 14.2 ± 2.0 minutes, respectively (P < .05). CONCLUSIONS: The MCO-IMRT and VMAT can create clinically acceptable plans for spinal radiosurgery. The MU for MCO-IMRT and VMAT can be reduced significantly by utilizing a collimator rotation following the orientation of the spinal cord. Plan quality for VMAT is similar to MCO-IMRT, with similar MU for both modalities. Delivery times can be reduced by nominally 25% with VMAT.
Asunto(s)
Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de la Columna Vertebral/cirugía , Humanos , Metástasis de la Neoplasia , Dosificación Radioterapéutica , Neoplasias de la Columna Vertebral/patología , Neoplasias de la Columna Vertebral/secundarioRESUMEN
PURPOSE: Proton radiotherapy allows radiation treatment delivery with high dose gradients. The nature of such dose distributions increases the influence of patient positioning uncertainties on their fidelity when compared to photon radiotherapy. The present work quantitatively analyzes the influence of setup uncertainties on proton range and dose distributions. METHODS: Thirty-eight clinical passive scattering treatment fields for small lesions in the head were studied. Dose distributions for shifted and rotated patient positions were Monte Carlo-simulated. Proton range uncertainties at the 50%- and 90%-dose falloff position were calculated considering 18 arbitrary combinations of maximal patient position shifts and rotations for two patient positioning methods. Normal tissue complication probabilities (NTCPs), equivalent uniform doses (EUDs), and tumor control probabilities (TCPs) were studied for organs at risk (OARs) and target volumes of eight patients. RESULTS: The authors identified a median 1σ proton range uncertainty at the 50%-dose falloff of 2.8 mm for anatomy-based patient positioning and 1.6 mm for fiducial-based patient positioning as well as 7.2 and 5.8 mm for the 90%-dose falloff position, respectively. These range uncertainties were correlated to heterogeneity indices (HIs) calculated for each treatment field (38%Asunto(s)
Posicionamiento del Paciente/métodos
, Terapia de Protones/métodos
, Incertidumbre
, Adulto
, Neoplasias Encefálicas/radioterapia
, Simulación por Computador
, Femenino
, Neoplasias de Cabeza y Cuello/radioterapia
, Humanos
, Masculino
, Persona de Mediana Edad
, Modelos Biológicos
, Método de Montecarlo
, Posicionamiento del Paciente/instrumentación
, Terapia de Protones/instrumentación
, Dosificación Radioterapéutica
, Rotación
RESUMEN
BACKGROUND: To precisely calculate skin dose and thus to evaluate the relationship between the skin dose and permanent alopecia for pediatric medulloblastoma patients treated with proton beams. METHODS: The dosimetry and alopecia outcomes of 12 children with medulloblastoma (ages 4-15 years) comprise the study cohort. Permanent alopecia was assessed and graded after completion of the entire therapy. Skin threshold doses of permanent alopecia were calculated based on the skin dose from the craniospinal irradiation (CSI) plan using the concept of generalized equivalent uniform dose (gEUD) and accounting for chemotherapy intensity. Monte Carlo simulations were employed to accurately assess uncertainties due to beam range prediction and secondary particles. RESULTS: Increasing the dose of the CSI field or the dose given by the boost field to the posterior fossa increased total skin dose delivered in that region. It was found that permanent alopecia could be correlated with CSI dose with a threshold of about 21 Gy (relative biological effectiveness, RBE) with high dose chemotherapy and 30 Gy (RBE) with conventional chemotherapy. CONCLUSIONS: Our results based on 12 patients provide a relationship between the skin dose and permanent alopecia for pediatric medulloblastoma patients treated with protons. The alopecia risk as assessed with gEUD could be predicted based on the treatment plan information.
Asunto(s)
Alopecia/etiología , Neoplasias Cerebelosas/radioterapia , Irradiación Craneoespinal/efectos adversos , Meduloblastoma/radioterapia , Terapia de Protones/efectos adversos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/efectos adversos , Adolescente , Niño , Preescolar , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Humanos , Masculino , Método de Montecarlo , Pronóstico , Dosificación Radioterapéutica , Efectividad Biológica RelativaRESUMEN
PURPOSE: Image guided radiation therapy (IGRT) has become common practice for both photon and proton radiation therapy, but there is little consensus regarding its application in the pediatric population. We evaluated clinical patterns of pediatric IGRT practice through an international pediatrics consortium comprised of institutions using either photon or proton radiation therapy. METHODS AND MATERIALS: Seven international institutions with dedicated pediatric expertise completed a 53-item survey evaluating patterns of IGRT use in definitive radiation therapy for patients ≤21 years old. Two institutions use proton therapy for children and all others use IG photon therapy. Descriptive statistics including frequencies of IGRT use and means and standard deviations for planning target volume (PTV) margins by institution and treatment site were calculated. RESULTS: Approximately 750 pediatric patients were treated annually across the 7 institutions. IGRT was used in tumors of the central nervous system (98%), abdomen or pelvis (73%), head and neck (100%), lung (83%), and liver (69%). Photon institutions used kV cone beam computed tomography and kV- and MV-based planar imaging for IGRT, and all proton institutions used kV-based planar imaging; 57% of photon institutions used a specialized pediatric protocol for IGRT that delivers lower dose than standard adult protocols. Immobilization techniques varied by treatment site and institution. IGRT was utilized daily in 45% and weekly in 35% of cases. The PTV margin with use of IGRT ranged from 2 cm to 1 cm across treatment sites and institution. CONCLUSIONS: Use of IGRT in children was prevalent at all consortium institutions. There was treatment site-specific variability in IGRT use and technique across institutions, although practices varied less at proton facilities. Despite use of IGRT, there was no consensus of optimum PTV margin by treatment site. Given the desire to restrict any additional radiation exposure in children to instances where the exposure is associated with measureable benefit, prospective studies are warranted to optimize IGRT protocols by modality and treatment site.
Asunto(s)
Tomografía Computarizada de Haz Cónico , Neoplasias/radioterapia , Fotones/uso terapéutico , Pautas de la Práctica en Medicina , Terapia de Protones , Radioterapia Guiada por Imagen , Adulto , Niño , Estudios de Seguimiento , Humanos , Agencias Internacionales , Neoplasias/diagnóstico por imagen , Pronóstico , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Radioterapia de Intensidad ModuladaRESUMEN
PURPOSE: The purpose of this study is to evaluate the potential of using in-room positron emission tomography (PET) for treatment verification in proton therapy and for deriving suitable PET scan times. METHODS AND MATERIALS: Nine patients undergoing passive scattering proton therapy underwent scanning immediately after treatment with an in-room PET scanner. The scanner was positioned next to the treatment head after treatment. The Monte Carlo (MC) method was used to reproduce PET activities for each patient. To assess the proton beam range uncertainty, we designed a novel concept in which the measured PET activity surface distal to the target at the end of range was compared with MC predictions. The repositioning of patients for the PET scan took, on average, approximately 2 minutes. The PET images were reconstructed considering varying scan times to test the scan time dependency of the method. RESULTS: The measured PET images show overall good spatial correlations with MC predictions. Some discrepancies could be attributed to uncertainties in the local elemental composition and biological washout. For 8 patients treated with a single field, the average range differences between PET measurements and computed tomography (CT) image-based MC results were <5 mm (<3 mm for 6 of 8 patients) and root-mean-square deviations were 4 to 11 mm with PET-CT image co-registration errors of approximately 2 mm. Our results also show that a short-length PET scan of 5 minutes can yield results similar to those of a 20-minute PET scan. CONCLUSIONS: Our first clinical trials in 9 patients using an in-room PET system demonstrated its potential for in vivo treatment monitoring in proton therapy. For a quantitative range prediction with arbitrary shape of target volume, we suggest using the distal PET activity surface.