RESUMEN
PURPOSE: To develop a new electromagnetic interference (EMI) elimination strategy for RF shielding-free MRI via active EMI sensing and deep learning direct MR signal prediction (Deep-DSP). METHODS: Deep-DSP is proposed to directly predict EMI-free MR signals. During scanning, MRI receive coil and EMI sensing coils simultaneously sample data within two windows (i.e., for MR data and EMI characterization data acquisition, respectively). Afterward, a residual U-Net model is trained using synthetic MRI receive coil data and EMI sensing coil data acquired during EMI signal characterization window, to predict EMI-free MR signals from signals acquired by MRI receive and EMI sensing coils. The trained model is then used to directly predict EMI-free MR signals from data acquired by MRI receive and sensing coils during the MR signal-acquisition window. This strategy was evaluated on an ultralow-field 0.055T brain MRI scanner without any RF shielding and a 1.5T whole-body scanner with incomplete RF shielding. RESULTS: Deep-DSP accurately predicted EMI-free MR signals in presence of strong EMI. It outperformed recently developed EDITER and convolutional neural network methods, yielding better EMI elimination and enabling use of few EMI sensing coils. Furthermore, it could work well without dedicated EMI characterization data. CONCLUSION: Deep-DSP presents an effective EMI elimination strategy that outperforms existing methods, advancing toward truly portable and patient-friendly MRI. It exploits electromagnetic coupling between MRI receive and EMI sensing coils as well as typical MR signal characteristics. Despite its deep learning nature, Deep-DSP framework is computationally simple and efficient.
Asunto(s)
Encéfalo , Aprendizaje Profundo , Imagen por Resonancia Magnética , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Humanos , Encéfalo/diagnóstico por imagen , Ondas de Radio , Fantasmas de Imagen , Campos Electromagnéticos , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Procesamiento de Señales Asistido por ComputadorRESUMEN
PURPOSE: To demonstrate magnetization transfer (MT) effects with low specific absorption rate (SAR) on ultra-low-field (ULF) MRI. METHODS: MT imaging was implemented by using sinc-modulated RF pulse train (SPT) modules to provide bilateral off-resonance irradiation. They were incorporated into 3D gradient echo (GRE) and fast spin echo (FSE) protocols on a shielding-free 0.055T head scanner. MT effects were first verified using phantoms. Brain MT imaging was conducted in both healthy subjects and patients. RESULTS: MT effects were clearly observed in phantoms using six SPT modules with total flip angle 3600° at central primary saturation bands of approximate offset ±786 Hz, even in the presence of large relative B0 inhomogeneity. For brain, strong MT effects were observed in gray matter, white matter, and muscle in 3D GRE and FSE imaging using six and sixteen SPT modules with total flip angle 3600° and 9600°, respectively. Fat, cerebrospinal fluid, and blood exhibited relatively weak MT effects. MT preparation enhanced tissue contrasts in T2-weighted and FLAIR-like images, and improved brain lesion delineation. The estimated MT SAR was 0.0024 and 0.0008 W/kg for two protocols, respectively, which is far below the US Food and Drug Administration (FDA) limit of 3.0 W/kg. CONCLUSION: Robust MT effects can be readily obtained at ULF with extremely low SAR, despite poor relative B0 homogeneity in ppm. This unique advantage enables flexible MT pulse design and implementation on low-cost ULF MRI platforms to achieve strong MT effects in brain and beyond, potentially augmenting their clinical utility in the future.
Asunto(s)
Encéfalo , Imagen por Resonancia Magnética , Fantasmas de Imagen , Humanos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagenología Tridimensional/métodos , Masculino , Adulto , Femenino , Algoritmos , Sustancia Gris/diagnóstico por imagen , Sustancia Blanca/diagnóstico por imagenRESUMEN
Low magnetic field magnetic resonance imaging (MRI) ( B 0 $$ {B}_0 $$ < 1 T) is regaining interest in the magnetic resonance (MR) community as a complementary, more flexible, and cost-effective approach to MRI diagnosis. Yet, the impaired signal-to-noise ratio (SNR) per square root of time, or SNR efficiency, leading in turn to prolonged acquisition times, still challenges its relevance at the clinical level. To address this, researchers investigate various hardware and software solutions to improve SNR efficiency at low field, including the leveraging of latest advances in computing hardware. However, there may not be a single recipe for improving SNR at low field, and it is key to embrace the challenges and limitations of each proposed solution. In other words, suitable solutions depend on the final objective or application envisioned for a low-field scanner and, more importantly, on the characteristics of a specific low B 0 $$ {B}_0 $$ field. In this review, we aim to provide an overview on software solutions to improve SNR efficiency at low field. First, we cover techniques for efficient k-space sampling and reconstruction. Then, we present post-acquisition techniques that enhance MR images such as denoising and super-resolution. In addition, we summarize recently introduced electromagnetic interference cancellation approaches showing great promises when operating in shielding-free environments. Finally, we discuss the advantages and limitations of these approaches that could provide directions for future applications.
RESUMEN
We aim to explore the feasibility of head and neck time-of-flight (TOF) magnetic resonance angiography (MRA) at ultra-low-field (ULF). TOF MRA was conducted on a highly simplified 0.05 T MRI scanner with no radiofrequency (RF) and magnetic shielding. A flow-compensated three-dimensional (3D) gradient echo (GRE) sequence with a tilt-optimized nonsaturated excitation RF pulse, and a flow-compensated multislice two-dimensional (2D) GRE sequence, were implemented for cerebral artery and vein imaging, respectively. For carotid artery and jugular vein imaging, flow-compensated 2D GRE sequences were utilized with venous and arterial blood presaturation, respectively. MRA was performed on young healthy subjects. Vessel-to-background contrast was experimentally observed with strong blood inflow effect and background tissue suppression. The large primary cerebral arteries and veins, carotid arteries, jugular veins, and artery bifurcations could be identified in both raw GRE images and maximum intensity projections. The primary brain and neck arteries were found to be reproducible among multiple examination sessions. These preliminary experimental results demonstrated the possibility of artery TOF MRA on low-cost 0.05 T scanners for the first time, despite the extremely low MR signal. We expect to improve the quality of ULF TOF MRA in the near future through sequence development and optimization, ongoing advances in ULF hardware and image formation, and the use of vascular T1 contrast agents.
Asunto(s)
Angiografía por Resonancia Magnética , Humanos , Angiografía por Resonancia Magnética/métodos , Masculino , Adulto , Femenino , Adulto Joven , Arterias Cerebrales/diagnóstico por imagen , Reproducibilidad de los ResultadosRESUMEN
The cortical distribution and functional role of cholecystokinin (CCK) are largely unknown. Here, a CCK receptor antagonist challenge paradigm was developed to assess functional connectivity and neuronal responses. Structural-functional magnetic resonance imaging and calcium imaging were undertaken in environmental enrichment (EE) and standard environment (SE) groups (naïve adult male mice, n = 59, C57BL/B6J, P = 60). Functional connectivity network-based statistics and pseudo-demarcation Voronoi tessellations to cluster calcium signals were used to derive region of interest metrics based on calcium transients, firing rate, and location. The CCK challenge elicited robust changes to structural-functional networks, decreased neuronal calcium transients, and max firing rate (5 s) of dorsal hippocampus in SE mice. However, the functional changes were not observed in EE mice, while the decreased neuronal calcium transients and max firing rate (5 s) were similar to SE mice. Decreased gray matter alterations were observed in multiple brain regions in the SE group due to CCK challenge, while no effect was observed in the EE group. The networks most affected by CCK challenge in SE included within isocortex, isocortex to olfactory, isocortex to striatum, olfactory to midbrain, and olfactory to thalamus. The EE group did not experience network changes in functional connectivity due to CCK challenge. Interestingly, calcium imaging revealed a significant decrease in transients and max firing rate (5 s) in the dorsal CA1 hippocampus subregion after CCK challenge in EE. Overall, CCK receptor antagonists affected brain-wide structural-functional connectivity within the isocortex, in addition to eliciting decreased neuronal calcium transients and max firing rate (5 s) in CA1 of the hippocampus. Future studies should investigate the CCK functional networks and how these processes affect isocortex modulation. Significance Statement Cholecystokinin is a neuropeptide predominately found in the gastrointestinal system. Albeit abundantly expressed in neurons, the role and distribution of cholecystokinin are largely unknown. Here, we demonstrate cholecystokinin affects brain-wide structural-functional networks within the isocortex. In the hippocampus, the cholecystokinin receptor antagonist challenge decreases neuronal calcium transients and max firing rate (5 s) in CA1. We further demonstrate that mice in environmental enrichment do not experience functional network changes to the CCK receptor antagonist challenge. Environmental enrichment may afford protection to the alterations observed in control mice due to CCK. Our results suggest that cholecystokinin is distributed throughout the brain, interacts in the isocortex, and demonstrates an unexpected functional network stability for enriched mice.
Asunto(s)
Colecistoquinina , Conectoma , Ratones , Masculino , Animales , Receptores de Colecistoquinina , Calcio , Ratones Endogámicos C57BL , HipocampoRESUMEN
Despite its prominence in learning and memory, hippocampal influence in early auditory processing centers remains unknown. Here, we examined how hippocampal activity modulates sound-evoked responses in the auditory midbrain and thalamus using optogenetics and functional MRI (fMRI) in rodents. Ventral hippocampus (vHP) excitatory neuron stimulation at 5 Hz evoked robust hippocampal activity that propagates to the primary auditory cortex. We then tested 5 Hz vHP stimulation paired with either natural vocalizations or artificial/noise acoustic stimuli. vHP stimulation enhanced auditory responses to vocalizations (with a negative or positive valence) in the inferior colliculus, medial geniculate body, and auditory cortex, but not to their temporally reversed counterparts (artificial sounds) or broadband noise. Meanwhile, pharmacological vHP inactivation diminished response selectivity to vocalizations. These results directly reveal the large-scale hippocampal participation in natural sound processing at early centers of the ascending auditory pathway. They expand our present understanding of hippocampus in global auditory networks.
Asunto(s)
Corteza Auditiva , Colículos Inferiores , Colículos Inferiores/fisiología , Vías Auditivas/fisiología , Corteza Auditiva/fisiología , Estimulación Acústica/métodos , Percepción Auditiva/fisiología , Cuerpos Geniculados/fisiología , HipocampoRESUMEN
PURPOSE: To develop a robust parallel imaging reconstruction method using spatial nulling maps (SNMs). METHODS: Parallel reconstruction using null operations (PRUNO) is a k-space reconstruction method where a k-space nulling system is derived using null-subspace bases of the calibration matrix. ESPIRiT reconstruction extends the PRUNO subspace concept by exploiting the linear relationship between signal-subspace bases and spatial coil sensitivity characteristics, yielding a hybrid-domain approach. Yet it requires empirical eigenvalue thresholding to mask the coil sensitivity information and is sensitive to signal- and null-subspace division. In this study, we combine the concepts of null-subspace PRUNO and hybrid-domain ESPIRiT to provide a more robust reconstruction method that extracts null-subspace bases of calibration matrix to calculate image-domain SNMs. Multi-channel images are reconstructed by solving an image-domain nulling system formed by SNMs that contain both coil sensitivity and finite image support information, therefore, circumventing the masking-related procedure. The proposed method was evaluated with multi-channel 2D brain and knee data and compared to ESPIRiT. RESULTS: The proposed hybrid-domain method produced quality reconstruction highly comparable to ESPIRiT with optimal manual masking. It involved no masking-related manual procedure and was tolerant of the actual division of null- and signal-subspace. Spatial regularization could be also readily incorporated to reduce noise amplification as in ESPIRiT. CONCLUSION: We provide an efficient hybrid-domain reconstruction method using multi-channel SNMs that are calculated from coil calibration data. It eliminates the need for coil sensitivity masking and is relatively insensitive to subspace separation, therefore, presenting a robust parallel imaging reconstruction procedure in practice.
Asunto(s)
Algoritmos , Imagen por Resonancia Magnética , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagen , Calibración , Procesamiento de Imagen Asistido por Computador/métodos , Fantasmas de ImagenRESUMEN
PURPOSE: Recent development of ultra-low-field (ULF) MRI presents opportunities for low-power, shielding-free, and portable clinical applications at a fraction of the cost. However, its performance remains limited by poor image quality. Here, a computational approach is formulated to advance ULF MR brain imaging through deep learning of large-scale publicly available 3T brain data. METHODS: A dual-acquisition 3D superresolution model is developed for ULF brain MRI at 0.055 T. It consists of deep cross-scale feature extraction, attentional fusion of two acquisitions, and reconstruction. Models for T1 -weighted and T2 -weighted imaging were trained with 3D ULF image data sets synthesized from the high-resolution 3T brain data from the Human Connectome Project. They were applied to 0.055T brain MRI with two repetitions and isotropic 3-mm acquisition resolution in healthy volunteers, young and old, as well as patients. RESULTS: The proposed approach significantly enhanced image spatial resolution and suppressed noise/artifacts. It yielded high 3D image quality at 0.055 T for the two most common neuroimaging protocols with isotropic 1.5-mm synthetic resolution and total scan time under 20 min. Fine anatomical details were restored with intrasubject reproducibility, intercontrast consistency, and confirmed by 3T MRI. CONCLUSION: The proposed dual-acquisition 3D superresolution approach advances ULF MRI for quality brain imaging through deep learning of high-field brain data. Such strategy can empower ULF MRI for low-cost brain imaging, especially in point-of-care scenarios or/and in low-income and mid-income countries.
Asunto(s)
Aprendizaje Profundo , Humanos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Imagenología Tridimensional/métodos , Neuroimagen/métodos , Encéfalo/diagnóstico por imagenRESUMEN
PURPOSE: To develop a truly calibrationless reconstruction method that derives An Eigenvalue Approach to Autocalibrating Parallel MRI (ESPIRiT) maps from uniformly-undersampled multi-channel MR data by deep learning. METHODS: ESPIRiT, one commonly used parallel imaging reconstruction technique, forms the images from undersampled MR k-space data using ESPIRiT maps that effectively represents coil sensitivity information. Accurate ESPIRiT map estimation requires quality coil sensitivity calibration or autocalibration data. We present a U-Net based deep learning model to estimate the multi-channel ESPIRiT maps directly from uniformly-undersampled multi-channel multi-slice MR data. The model is trained using fully-sampled multi-slice axial brain datasets from the same MR receiving coil system. To utilize subject-coil geometric parameters available for each dataset, the training imposes a hybrid loss on ESPIRiT maps at the original locations as well as their corresponding locations within the standard reference multi-slice axial stack. The performance of the approach was evaluated using publicly available T1-weighed brain and cardiac data. RESULTS: The proposed model robustly predicted multi-channel ESPIRiT maps from uniformly-undersampled k-space data. They were highly comparable to the reference ESPIRiT maps directly computed from 24 consecutive central k-space lines. Further, they led to excellent ESPIRiT reconstruction performance even at high acceleration, exhibiting a similar level of errors and artifacts to that by using reference ESPIRiT maps. CONCLUSION: A new deep learning approach is developed to estimate ESPIRiT maps directly from uniformly-undersampled MR data. It presents a general strategy for calibrationless parallel imaging reconstruction through learning from the coil and protocol-specific data.
Asunto(s)
Aprendizaje Profundo , Procesamiento de Imagen Asistido por Computador/métodos , Algoritmos , Imagen por Resonancia Magnética/métodos , Encéfalo/diagnóstico por imagenRESUMEN
At present, MRI scans are typically performed inside fully enclosed radiofrequency (RF) shielding rooms, posing stringent installation requirements and causing patient discomfort. We aim to eliminate electromagnetic interference (EMI) for MRI with no or incomplete RF shielding. In this study, a method of active sensing and deep learning EMI prediction is presented to model, predict, and remove EMI signal components from acquired MRI signals. Specifically, during each MRI scan, separate EMI-sensing coils placed in various locations are utilized to simultaneously sample external and internal EMI signals within two windows (for both conventional MRI signal acquisition and EMI characterization acquisition). A convolution neural network model is trained using the EMI characterization data to relate EMI signals detected by EMI-sensing coils to EMI signals in the MRI receive coil. This model is then used to retrospectively predict and remove EMI signal components detected by the MRI receive coil during the MRI signal acquisition window. This strategy was implemented on a low-cost ultralow-field 0.055 T permanent magnet MRI scanner without RF shielding. It produced final image signal-to-noise ratios that were comparable with those obtained using a fully enclosed RF shielding cage, and outperformed existing analytical EMI elimination methods (i.e., spectral domain transfer function and external dynamic interference estimation and removal [EDITER] methods). A preliminary experiment also demonstrated its applicability on a 1.5 T superconducting magnet MRI scanner with incomplete RF shielding. Altogether, the results demonstrated that the proposed method was highly effective in predicting and removing various EMI signals from both external environments and internal scanner electronics at both 0.055 T (2.3 MHz) and 1.5 T (63.9 MHz). The proposed strategy enables shielding-free MRI. The concept is relatively simple and is potentially applicable to other RF signal detection scenarios in the presence of external and/or internal EMI.
RESUMEN
Environmental enrichment induces widespread neuronal changes, but the initiation of the cascade is unknown. We ascertained the critical period of divergence between environmental enriched (EE) and standard environment (SE) mice using continuous infrared (IR) videography, functional magnetic resonance imaging (fMRI), and neuron level calcium imaging. Naïve adult male mice (n = 285, C57BL/6J, postnatal day 60) were divided into SE and EE groups. We assessed the linear time-series of motion activity using a novel structural break test which examined the dataset for change in circadian and day-by-day motion activity. fMRI was used to map brain-wide response using a functional connectome analysis pipeline. Awake calcium imaging was performed on the dorsal CA1 pyramidal layer. We found the preeminent behavioral feature in EE was a forward shift in the circadian rhythm, prolongation of activity in the dark photoperiod, and overall decreased motion activity. The crepuscular period of dusk was seen as the critical period of divergence between EE and SE mice. The functional processes at dusk in EE included increased functional connectivity in the visual cortex, motor cortex, retrosplenial granular cortex, and cingulate cortex using seed-based analysis. Network based statistics found a modulated functional connectome in EE concentrated in two hubs: the hippocampal formation and isocortical network. These hubs experienced a higher node degree and significant enhanced edge connectivity. Calcium imaging revealed increased spikes per second and maximum firing rate in the dorsal CA1 pyramidal layer, in addition to location (anterior-posterior and medial-lateral) effect size differences between EE and SE. The emergence of functional-neuronal changes due to enrichment consisted of enhanced hippocampal-isocortex functional connectivity and CA1 neuronal increased spiking linked to a circadian shift during the dusk period. Future studies should explore the molecular consequences of enrichment inducing shifts in the circadian period.
Asunto(s)
Calcio , Ambiente , Animales , Encéfalo/fisiología , Hipocampo , Humanos , Masculino , Ratones , Ratones Endogámicos C57BLRESUMEN
PURPOSE: To develop a joint denoising method that effectively exploits natural information redundancy in MR DWIs via low-rank patch matrix approximation. METHODS: A denoising method is introduced to jointly reduce noise in DWI dataset by exploiting nonlocal self-similarity as well as local anatomical/structural similarity within multiple 2D DWIs acquired with the same anatomical geometry but different diffusion directions. Specifically, for each small 3D reference patch sliding within 2D DWI, nonlocal but similar patches are searched by matching image contents within entire DWI dataset and then structured into a patch matrix. The resulting patch matrices are denoised by enforcing low-rankness via weighted nuclear norm minimization and finally are back-distributed to DWI space. The proposed procedure was evaluated with simulated and in vivo brain diffusion tensor imaging (DTI) datasets and then compared to existing Marchenko-Pastur principal component analysis denoising method. RESULTS: The proposed method achieved significant noise reduction while preserving structural details in all DWIs for both simulated and in vivo datasets. Quantitative evaluation of error maps demonstrated it consistently outperformed Marchenko-Pastur principal component analysis method. Further, the denoised DWIs led to substantially improved DTI parametric maps, exhibiting significantly less noise and revealing more microstructural details. CONCLUSION: The proposed method denoises DWI dataset by utilizing both nonlocal self-similarity and local structural similarity within DWI dataset. This weighted nuclear norm minimization-based low-rank patch matrix denoising approach is effective and highly applicable to various diffusion MRI applications, including DTI as a postprocessing procedure.
Asunto(s)
Algoritmos , Imagen de Difusión Tensora , Encéfalo/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Relación Señal-RuidoRESUMEN
PURPOSE: To provide a complex-valued deep learning approach for partial Fourier (PF) reconstruction of complex MR images. METHODS: Conventional PF reconstruction methods, such as projection onto convex sets (POCS), uses low-resolution image phase information from the central symmetrically sampled k-space for image reconstruction. However, this smooth phase constraint undermines the phase estimation accuracy in presence of rapid local phase variations, causing image artifacts and limiting the extent of PF reconstruction. Using both magnitude and phase characteristics in big complex image datasets, we propose a complex-valued deep learning approach with an unrolled network architecture for PF reconstruction that iteratively reconstructs PF sampled data and enforces data consistency. We evaluate our approach for reconstructing both spin-echo and gradient-echo data. RESULTS: The proposed method outperformed the iterative POCS PF reconstruction method. It produced better artifact suppression and recovery of both image magnitude and phase details in presence of local phase changes. No noise amplification was observed even for highly PF reconstruction. Moreover, the network trained on axial brain data could reconstruct sagittal and coronal brain and knee data. This method could be extended to 2D PF reconstruction and joint multi-slice PF reconstruction. CONCLUSION: Our proposed method can effectively reconstruct MR data even at low PF fractions, yielding high-fidelity magnitude and phase images. It presents a valuable alternative to conventional PF reconstruction, especially for phase-sensitive 2D or 3D MRI applications.
Asunto(s)
Procesamiento de Imagen Asistido por Computador , Variación de la Fase , Algoritmos , Humanos , Imagen por Resonancia Magnética , Redes Neurales de la ComputaciónRESUMEN
We propose a multi-slice acquisition with orthogonally alternating phase encoding (PE) direction and subsequent joint calibrationless reconstruction for accelerated multiple individual 2D slices or multi-slice 2D Cartesian MRI. Specifically, multi-slice multi-channel data are first acquired with random or uniform PE undersampling while orthogonally alternating PE direction between adjacent slices. They are then jointly reconstructed through a recently developed low-rank multi-slice Hankel tensor completion (MS-HTC) approach. The proposed acquisition and reconstruction strategy was evaluated with human brain MR data. It effectively suppressed aliasing artifacts even at high acceleration factor, outperforming the existing MS-HTC approach, where PE direction is the same between adjacent slices. More importantly, the new strategy worked robustly with uniform undersampling or random undersampling without any consecutive central k-space lines. In summary, our proposed multi-slice MRI strategy exploits both coil sensitivity and image content similarities across adjacent slices. Orthogonally alternating PE direction among slices substantially facilitates the low-rank completion process and improves image reconstruction quality. This new strategy is applicable to uniform and random PE undersampling. It can be easily implemented in practice for Cartesian parallel imaging of multiple individual 2D slices without any coil sensitivity calibration.
Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Algoritmos , Artefactos , Encéfalo/diagnóstico por imagen , Calibración , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodosRESUMEN
Blood oxygen level-dependent functional MRI (fMRI) constitutes a powerful neuroimaging technology to map brain-wide functions in response to specific sensory or cognitive tasks. However, fMRI mapping of the vestibular system, which is pivotal for our sense of balance, poses significant challenges. Physical constraints limit a subject's ability to perform motion- and balance-related tasks inside the scanner, and current stimulation techniques within the scanner are nonspecific to delineate complex vestibular nucleus (VN) pathways. Using fMRI, we examined brain-wide neural activity patterns elicited by optogenetically stimulating excitatory neurons of a major vestibular nucleus, the ipsilateral medial VN (MVN). We demonstrated robust optogenetically evoked fMRI activations bilaterally at sensorimotor cortices and their associated thalamic nuclei (auditory, visual, somatosensory, and motor), high-order cortices (cingulate, retrosplenial, temporal association, and parietal), and hippocampal formations (dentate gyrus, entorhinal cortex, and subiculum). We then examined the modulatory effects of the vestibular system on sensory processing using auditory and visual stimulation in combination with optogenetic excitation of the MVN. We found enhanced responses to sound in the auditory cortex, thalamus, and inferior colliculus ipsilateral to the stimulated MVN. In the visual pathway, we observed enhanced responses to visual stimuli in the ipsilateral visual cortex, thalamus, and contralateral superior colliculus. Taken together, our imaging findings reveal multiple brain-wide central vestibular pathways. We demonstrate large-scale modulatory effects of the vestibular system on sensory processing.
Asunto(s)
Mapeo Encefálico , Núcleos Vestibulares/fisiología , Animales , Percepción Auditiva/fisiología , Imagen por Resonancia Magnética , Masculino , Optogenética , Ratas Sprague-Dawley , Percepción Visual/fisiologíaRESUMEN
Brain possesses a complex spatiotemporal architecture for efficient information processing and computing. However, it remains unknown how neural signal propagates to its intended targets brain-wide. Using optogenetics and functional MRI, we arbitrarily initiated various discrete neural activity pulse trains with different temporal patterns and revealed their distinct long-range propagation targets within the well-defined, topographically organized somatosensory thalamo-cortical circuit. We further observed that such neural activity propagation over long range could modulate brain-wide sensory functions. Electrophysiological analysis indicated that distinct propagation pathways arose from system level neural adaptation and facilitation in response to the neural activity temporal characteristics. Together, our findings provide fundamental insights into the long-range information transfer and processing. They directly support that temporal coding underpins the whole brain functional architecture in presence of the vast and relatively static anatomical architecture.
Asunto(s)
Encéfalo/fisiología , Vías Nerviosas/fisiología , Animales , Mapeo Encefálico , Imagen por Resonancia Magnética , Masculino , Red Nerviosa/fisiología , Optogenética , Ratas , Ratas Sprague-Dawley , Corteza Somatosensorial/fisiología , Tálamo/fisiologíaRESUMEN
PURPOSE: To jointly reconstruct highly undersampled multicontrast two-dimensional (2D) datasets through a low-rank Hankel tensor completion framework. METHODS: A multicontrast Hankel tensor completion (MC-HTC) framework is proposed to exploit the shareable information in multicontrast datasets with respect to their highly correlated image structure, common spatial support, and shared coil sensitivity for joint reconstruction. This is achieved by first organizing multicontrast k-space datasets into a single block-wise Hankel tensor. Subsequent low-rank tensor approximation via higher-order singular value decomposition (HOSVD) uses the image structural correlation by considering different contrasts as virtual channels. Meanwhile, the HOSVD imposes common spatial support and shared coil sensitivity by treating data from different contrasts as from additional k-space kernels. The missing k-space data are then recovered by iteratively performing such low-rank approximation and enforcing data consistency. This joint reconstruction framework was evaluated using multicontrast multichannel 2D human brain datasets (T1 -weighted, T2 -weighted, fluid-attenuated inversion recovery, and T1 -weighted-inversion recovery) of identical image geometry with random and uniform undersampling schemes. RESULTS: The proposed method offered high acceleration, exhibiting significantly less residual errors when compared with both single-contrast SAKE (simultaneous autocalibrating and k-space estimation) and multicontrast J-LORAKS (joint parallel-imaging-low-rank matrix modeling of local k-space neighborhoods) low-rank reconstruction. Furthermore, the MC-HTC framework was applied uniquely to Cartesian uniform undersampling by incorporating a novel complementary k-space sampling strategy where the phase-encoding direction among different contrasts is orthogonally alternated. CONCLUSION: The proposed MC-HTC approach presents an effective tensor completion framework to jointly reconstruct highly undersampled multicontrast 2D datasets without coil-sensitivity calibration.
Asunto(s)
Algoritmos , Imagen por Resonancia Magnética , Encéfalo/diagnóstico por imagen , Calibración , Medios de Contraste , Humanos , Procesamiento de Imagen Asistido por ComputadorRESUMEN
PURPOSE: To provide joint calibrationless parallel imaging reconstruction of highly accelerated multislice 2D MR k-space data. METHODS: Adjacent image slices in multislice MR data have similar coil sensitivity maps, spatial support, and image content. Such similarities can be utilized to improve image quality by reconstructing multiple slices jointly with low-rank tensor completion. Specifically, the multichannel k-space data from multiple slices are constructed into a block-wise Hankel tensor and iteratively updated by promoting tensor low-rankness through higher-order SVD. This multislice block-wise Hankel tensor completion was implemented for 2D spiral and Cartesian k-space undersampling where sampling patterns vary between adjacent slices. The approach was evaluated with human brain MR data and compared to the traditional single-slice simultaneous autocalibrating and k-space estimation reconstruction. RESULTS: The proposed multislice block-wise Hankel tensor completion approach robustly reconstructed highly undersampled multislice 2D spiral and Cartesian data. It produced substantially lower level of artifacts compared to the traditional single-slice simultaneous autocalibrating and k-space estimation reconstruction. Quantitative evaluation using error maps and root mean square error demonstrated its significantly improved performance in terms of residual artifacts and root mean square error. CONCLUSION: Our proposed multislice block-wise Hankel tensor completion method exploits the similar coil sensitivity and image content within multislice MR data through a tensor completion framework. It offers a new and effective approach to acquire and reconstruct highly undersampled multislice MR data in a calibrationless manner.
Asunto(s)
Algoritmos , Procesamiento de Imagen Asistido por Computador , Artefactos , Encéfalo/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Fantasmas de ImagenRESUMEN
PURPOSE: Examine the feasibility of characterizing the regulation of renal oxygenation using high-temporal-resolution monitoring of the T2∗ response to a step-like oxygenation stimulus. METHODS: For T2∗ mapping, multi-echo gradient-echo imaging was used (temporal resolution = 9 seconds). A step-like renal oxygenation challenge was applied involving sequential exposure to hyperoxia (100% O2 ), hypoxia (10% O2 + 90% N2 ), and hyperoxia (100% O2 ). In vivo experiments were performed in healthy rats (N = 10) and in rats with bilateral ischemia-reperfusion injury (N = 4). To assess the step response of renal oxygenation, a second-order exponential model was used (model parameters: amplitude [A], time delay [Δt], damping constant [D], and period of the oscillation [T]) for renal cortex, outer stripe of the outer medulla, inner stripe of the outer medulla, and inner medulla. RESULTS: The second-order exponential model permitted us to model the exponential T2∗ recovery and the superimposed T2∗ oscillation following renal oxygenation stimulus. The in vivo experiments revealed a difference in Douter medulla between healthy controls (D < 1, indicating oscillatory recovery) and ischemia-reperfusion injury (D > 1, reflecting aperiodic recovery). The increase in Douter medulla by a factor of 3.7 (outer stripe of the outer medulla) and 10.0 (inner stripe of the outer medulla) suggests that this parameter might be rather sensitive to (patho)physiological oxygenation changes. CONCLUSION: This study demonstrates the feasibility of monitoring the dynamic oxygenation response of renal tissues to a step-like oxygenation challenge using high-temporal-resolution T2∗ mapping. Our results suggest that the implemented system analysis approach may help to unlock questions regarding regulation of renal oxygenation, with the ultimate goal of providing imaging means for diagnostics and therapy of renal diseases.
Asunto(s)
Hiperoxia , Daño por Reperfusión , Animales , Hiperoxia/diagnóstico por imagen , Hipoxia , Riñón/diagnóstico por imagen , Corteza Renal/diagnóstico por imagen , Médula Renal/diagnóstico por imagen , Imagen por Resonancia Magnética , Oxígeno , RatasRESUMEN
BACKGROUND: Proteoglycan (PG) is a major component of the intervertebral disc extracellular matrix (ECM) that acts to hydrate the disc nucleus. Early detection of PG degradation is valuable for both diagnosis and preclinical research of intervertebral disc degeneration (IVDD). PURPOSE: To compare different MR techniques for detecting early degradative changes of PG in IVDD. STUDY TYPE: Prospective. PHANTOM/SPECIMEN: Glycosaminoglycan (GAG) phantom/bovine discs with papain injection and human cadaveric discs. FIELD STRENGTH/SEQUENCES: 7T/diffusion-weighted MR spectroscopy (DW-MRS), T2 -weighted MRS (T2 W-MRS), and chemical exchange saturation transfer (CEST) imaging. ASSESSMENT: DW-MRS, T2 W-MRS, and CEST imaging were applied longitudinally to measure PG diffusivity, T2 value, overall content, and spatial distribution in the disc nucleus with enzyme-induced proteolytic ECM degradation (n = 8). Similar MR measurements were applied in GAG phantom and human cadaveric discs with different levels of degeneration (n = 6). STATISTICAL TESTS: T-tests were conducted to measure the differences of PG properties between pre- and post-enzyme injection. Linear regression and mixed-effects models were used to assess the associations among different PG properties as well as the degeneration grades in human cadaveric discs. RESULTS: In bovine discs, PG diffusivity increased most rapidly after the enzyme was injected into the disc nucleus (12 hours postinjection, t = 5.76, P = 0.0007). The PG T2 value did not change significantly (t < 1.54, P > 0.17 for all timepoints) during ECM degradation and was not associated with PG diffusivity (t = 0.06, P = 0.95). PG distribution change was more rapid than overall PG content and was strongly associated with PG diffusivity increase (t = -9.25, P < 1 × 10-8 ). In severely degenerated human cadaveric discs, the PG ADCs and T2 values were both associated with degeneration grades. DATA CONCLUSION: PG diffusivity is a direct biomarker for early ECM degradation, while PG distribution can be an indirect biomarker for early IVDD. LEVEL OF EVIDENCE: 2 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2020;51:1390-1400.