1.
Sensors (Basel) ; 22(23)2022 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-36501777

RESUMEN

Herein a gold nanosphere (AuNS)-coated wavelength-mode localized surface plasmon resonance (LSPR) fiber sensor was fabricated by a simple and time-saving electrostatic self-assembly method using poly(allylamine hydrochloride). Based on the localized enhanced coupling effect between AuNSs, the LSPR spectrums of the AuNS monolayer with good dispersity and high density exhibited a favourable capability for refractive index (RI) measurement. Based on the results obtained from the optimization for AuNS distribution, sensing length, and RI range, the best RI sensitivity of the fiber modified by 100 nm AuNS reached up to about 2975 nm/RIU, with the surrounding RI range from 1.3322 to 1.3664. Using an 80 nm AuNS-modified fiber sensor, the RI sensitivity of 3953 nm/RIU was achieved, with the RI range increased from 1.3744 to 1.3911. The effect of sensing length to RI sensitivity was proven to be negligible. Furthermore, the linear relationship between the RI sensitivity and plasma resonance frequency of the bulk metal, which was dependent on the interparticle plasmon coupling effect, was quantified. Additionally, the resonance peak was tuned from 539.18 nm to 820.48 nm by different sizes of AuNSs-coated fiber sensors at a RI of 1.3322, which means the spectrum was extended from VIS to NIR. It has enormous potential in hypersensitive biochemistry detection at VIS and NIR ranges.


Asunto(s)
Refractometría , Resonancia por Plasmón de Superficie , Resonancia por Plasmón de Superficie/métodos , Refractometría/métodos , Oro
2.
Sensors (Basel) ; 20(22)2020 Nov 23.
Artículo en Inglés | MEDLINE | ID: mdl-33238386

RESUMEN

Mercury ions (Hg2+) pollution in the water environment can cause serious harm to human health. Trace Hg2+ detection is of vital importance for environmental monitoring. Herein, we report a novel design of Ru-MOFs modified gold microelectrode for Hg2+ determination. Ru-MOFs are synthesized directly by the cathodic method on gold microelectrode, with the covered area accurately controlled. Cathodic synthesized Ru-MOFs show good conductivity and are suitable to be used as the electrode surface material directly. The synergy of the pre-deposition process and the adsorption process of Ru-MOFs can effectively improves the performance of the sensor. The results show good linearity (R2 = 0.996) from 0.1 ppb to 5 ppb, with a high sensitivity of 0.583 µA ppb-1 mm-2. The limit of detection is found to be 0.08 ppb and the test process is within 6 min. Most importantly, the senor has a good anti-interference ability and the recoveries are satisfactory. This miniature electrochemical sensor has the potential for on-site detection of trace mercury in the field.

3.
Sensors (Basel) ; 18(3)2018 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-29543744

RESUMEN

One of the major concerns in the development of three-dimensional (3D) electric field sensors (EFSs) is their susceptibility to cross-axis coupling interference. The output signal for each sensing axis of a 3D EFS is often coupled by electric field components from the two other orthogonal sensing axes. In this paper, a one-dimensional (1D) electric field sensor chip (EFSC) with low cross-axis coupling interference is presented. It is designed to be symmetrical, forming a pair of in-plane symmetrically-located sensing structures. Using a difference circuit, the 1D EFSC is capable of sensing parallel electric fields along symmetrical structures and eliminating cross-axis coupling interference, which is contrast to previously reported 1D EFSCs designed for perpendicular electric field component measurement. Thus, a 3D EFS with low cross-axis coupling interference can be realized using three proposed 1D EFSCs. This 3D EFS has the advantages of low cross-axis coupling interference, small size, and high integration. The testing and calibration systems of the proposed 3D EFS were developed. Experimental results show that in the range of 0-120 kV/m, cross-axis sensitivities are within 5.48%, and the total measurement errors of this 3D EFS are within 6.16%.

4.
Sensors (Basel) ; 18(1)2018 Jan 19.
Artículo en Inglés | MEDLINE | ID: mdl-29351210

RESUMEN

This paper proposes a high sensitivity electric field microsensor (EFM) based on torsional resonance. The proposed microsensor adopts torsional shutter, which is composed of shielding electrodes and torsional beams. The movable shielding electrodes and the fixed sensing electrodes are fabricated on the same plane and interdigitally arranged. Push-pull electrostatic actuation method is employed to excite the torsional shutter. Simulation results proved that the torsional shutter has higher efficiency of charge induction. The optimization of structure parameters was conducted to improve its efficiency of charge induction further. A micromachining fabrication process was developed to fabricate the EFM. Experiments were conducted to characterize the EFM. A good linearity of 0.15% was achieved within an electrostatic field range of 0-50 kV/m, and the uncertainty was below 0.38% in the three roundtrip measurements. A high sensitivity of 4.82 mV/(kV/m) was achieved with the trans-resistance of 100 MΩ, which is improved by at least one order of magnitude compared with previously reported EFMs. The efficiency of charge induction for this microsensor reached 48.19 pA/(kV/m).

5.
Sensors (Basel) ; 17(11)2017 Nov 10.
Artículo en Inglés | MEDLINE | ID: mdl-29125543

RESUMEN

We have developed a novel mediated biochemical oxygen demand (BOD) biosensor based on immobilized Bacillus subtilis (B. subtilis) on three-dimensional (3D) porous graphene-polypyrrole (rGO-PPy) composite. The 3D porous rGO-PPy composite was prepared using hydrothermal method following with electropolymerization. Then the 3D porous rGO-PPy composite was used as a support for immobilizing negatively charged B. subtilis denoted as rGO-PPy-B through coordination and electrostatic interaction. Further, the prepared rGO-PPy-B was used as a microbial biofilm for establishing a mediated BOD biosensor with ferricyanide as an electronic acceptor. The indirect determination of BOD was performed by electrochemical measuring ferrocyanide generated from a reduced ferricyanide mediator using interdigited ultramicroelectrode array (IUDA) as the working electrode. The experimental results suggested a good linear relationship between the amperometric responses and BOD standard concentrations from 4 to 60 mg/L, with a limit detection of 1.8 mg/L (S/N ≥ 3). The electrochemical measurement of real water samples showed a good agreement with the conventional BOD5 method, and the good anti-interference as well as the long-term stability were well demonstrated, indicating that the proposed mediated BOD biosensor in this study holds a potential practical application of real water monitoring.


Asunto(s)
Técnicas Biosensibles , Bacillus subtilis , Grafito , Polímeros , Pirroles
6.
Sensors (Basel) ; 17(1)2017 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-28098824

RESUMEN

Water contamination is a main inducement of human diseases. It is an important step to monitor the water quality in the water distribution system. Due to the features of large size, high cost, and complicated structure of traditional water determination sensors and devices, it is difficult to realize real-time water monitoring on a large scale. In this paper, we present a multi-parameter sensor chip, which is miniature, low-cost, and robust, to detect the pH, conductivity, and temperature of water simultaneously. The sensor chip was fabricated using micro-electro-mechanical system (MEMS) techniques. Iridium oxide film was electrodeposited as the pH-sensing material. The atomic ratio of Ir(III) to Ir(IV) is about 1.38 according to the X-ray photoelectron spectroscopy (XPS) analysis. The pH sensing electrode showed super-Nernstian response (-67.60 mV/pH) and good linearity (R² = 0.9997), in the range of pH 2.22 to pH 11.81. KCl-agar and epoxy were used as the electrolyte layer and liquid junction for the solid-state reference electrode, respectively, and its potential stability in deionized water was 56 h. The conductivity cell exhibited a linear determination range from 21.43 µ S / cm to 1.99 mS / cm , and the electrode constant was 1.566 cm-1. Sensitivity of the temperature sensor was 5.46 Ω / ° C . The results indicate that the developed sensor chip has potential application in water quality measurements.


Asunto(s)
Calidad del Agua , Electrodos , Electrólitos , Concentración de Iones de Hidrógeno , Sistemas Microelectromecánicos
7.
Sensors (Basel) ; 17(3)2017 Mar 19.
Artículo en Inglés | MEDLINE | ID: mdl-28335500

RESUMEN

Poly(3,4-ethylenedioxythiophene) (PEDOT) films were prepared by electro-oxidation on Au microelectrodes in an aqueous solution. Electrolyte solutions and polymerization parameters were optimized prior to overoxidation. The effect of overoxidation time has been optimized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS), which results in the film overoxidized for 45 s at 1.35 V presenting a strong adsorption. The other one-step overoxidation film prepared by direct CV ranging from -0.6 V to 1.35 V was polymerized for comparison. Scanning electron microscope (SEM) analysis and Fourier transform infrared (FTIR) spectroscopy were used for monitoring morphological changes and the evolution of functional groups. Both of them indicate increased abundant oxygen functional groups and roughness, yet the products exhibit dendritic morphology and piles of spherical protrusions, respectively. Moreover, double-step overoxidized film showed better electrochemical performance toward lead ion sensing. These characterizations highlight some novel properties that may be beneficial for specific sensing applications.

8.
Sensors (Basel) ; 15(6): 12560-72, 2015 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-26024421

RESUMEN

Terahertz (THz) spectroscopy and multivariate data analysis were explored to discriminate eight wheat varieties. The absorption spectra were measured using THz time-domain spectroscopy from 0.2 to 2.0 THz. Using partial least squares (PLS), a regression model for discriminating wheat varieties was developed. The coefficient of correlation in cross validation (R) and root-mean-square error of cross validation (RMSECV) were 0.985 and 1.162, respectively. In addition, interval PLS was applied to optimize the models by selecting the most appropriate regions in the spectra, improving the prediction accuracy (R = 0.992 and RMSECV = 0.967). Results demonstrate that THz spectroscopy combined with multivariate analysis can provide rapid, nondestructive discrimination of wheat varieties.


Asunto(s)
Espectroscopía de Terahertz/métodos , Triticum/química , Triticum/clasificación , Calibración , Análisis de los Mínimos Cuadrados , Reproducibilidad de los Resultados
9.
Sensors (Basel) ; 15(9): 23249-61, 2015 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-26389904

RESUMEN

A microband electrode array modified with palladium-tin bimetallic composite has been developed for nitrate determination. The microband electrode array was fabricated by Micro Electro-Mechanical System (MEMS) technique. Palladium and tin were electrodeposited successively on the electrode, forming a double-layer structure. The effect of the Pd-Sn composite was investigated and its enhancement of catalytic activity and lifetime was revealed. The Pd-Sn modified electrode showed good linearity (R² = 0.998) from 1 mg/L to 20 mg/L for nitrate determination with a sensitivity of 398 µA/(mg∙L(-1)∙cm²). The electrode exhibited a satisfying analytical performance after 60 days of storage, indicating a long lifetime. Good repeatability was also displayed by the Pd-Sn modified electrodes. The results provided an option for nitrate determination in water.


Asunto(s)
Técnicas Biosensibles/instrumentación , Nitratos/análisis , Paladio/química , Estaño/química , Análisis por Micromatrices/instrumentación , Microelectrodos , Nanocompuestos/química , Nitratos/metabolismo , Oxidación-Reducción , Sensibilidad y Especificidad , Estaño/metabolismo
10.
Opt Express ; 22(10): 12533-44, 2014 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-24921371

RESUMEN

The terahertz (THz) spectra in the range of 0.2-1.6 THz (6.6-52.8 cm-1) of wheat grains with various degrees of deterioration (normal, worm-eaten, moldy, and sprouting wheat grains) were investigated by terahertz time domain spectroscopy. Principal component analysis (PCA) was employed to extract feature data according to the cumulative contribution rates; the top four principal components were selected, and then a support vector machine (SVM) method was applied. Several selection kernels (linear, polynomial, and radial basis functions) were applied to identify the four types of wheat grain. The results showed that the materials were identified with an accuracy of nearly 95%. Furthermore, this approach was compared with others (principal component regression, partial least squares regression, and back-propagation neural networks). The comparisons showed that PCA-SVM outperformed the others and also indicated that the proposed method of THz technology combined with PCA-SVM is efficient and feasible for identifying wheat of different qualities.


Asunto(s)
Algoritmos , Redes Neurales de la Computación , Análisis de Componente Principal/métodos , Espectroscopía de Terahertz/métodos , Triticum/química , Programas Informáticos
11.
Sensors (Basel) ; 14(12): 24472-82, 2014 Dec 19.
Artículo en Inglés | MEDLINE | ID: mdl-25536001

RESUMEN

This work describes the fabrication, characterization, and application of a gold microband array electrode (MAE) for the determination of phosphate in fresh water samples. The working principle of this MAE is based on the reduction of a molybdophosphate complex using the linear sweep voltammetric (LSV) method. The calibration of this microsensor was performed with standard phosphate solutions prepared with KH2PO4 and pH adjusted to 1.0. The microsensor consists of a platinum counter electrode, a gold MAE as working electrode, and an Ag/AgCl electrode as reference electrode. The microelectrode chips were fabricated by the Micro Electro-Mechanical System (MEMS) technique. To improve the sensitivity, gold nanoparticles (AuNPs) were electrodeposited on the working electrode. With a linear range from 0.02 to 0.50 mg P/L, the sensitivity of the unmodified microsensor is 2.40 µA per (mg P/L) (R2 = 0.99) and that of the AuNPs-modified microsensor is 7.66 µA per (mg P/L) (R2 = 0.99). The experimental results showed that AuNPs-modified microelectrode had better sensitivity and a larger current response than the unmodified microelectrode.

12.
Sensors (Basel) ; 15(1): 382-93, 2014 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-25549176

RESUMEN

This paper investigated two different modification methods of graphene (GN) on ultramicroelectrode array (UMEA) and applied the GN modified UMEA for the determination of dissolved oxygen (DO). The UMEAs were fabricated by Micro Electro-Mechanical System (MEMS) technique and the radius of each ultramicroelectrode is 10 µm. GN-NH2 and GN-COOH were modified on UMEA by using self-assembling method. Compared with GN-NH2 modified UMEA, the GN-COOH modified UMEA showed better electrochemical reduction to DO, owing to better dispersing and more active sites. The GN-COOH on UMEA was electroreduced to reduced GN-COOH (rGN-COOH) to increase the conductivity and the catalysis performance. Finally, the palladium nanoparticles/rGN-COOH composite was incorporated into DO microsensor for the detection of DO.

13.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(11): 2897-900, 2014 Nov.
Artículo en Zh | MEDLINE | ID: mdl-25752027

RESUMEN

Terahertz time-domain spectroscopy (THz-TDS) is used to investigate the spectra properties of the wheat kernel with various deterioration degrees in the frequency range of 0.2-1.6 THz. The absorption coefficient and refractive index of normal, worm-eaten, moldy and sprouting wheat kernel were calculated. Comparison of the experimental data, clearly indicates that changes in the absorption coefficient and refractive index are recorded, different wheat samples have different optical parameters. The absorption coefficient of normal wheat sample is more obvious and higher than others; refractive index increases as the frequency increases. THz-TDS can be employed to evaluate the quality of wheat kernel nondestructively. The results show that THz-TDS is a promising and new experimental method for quality analyses and control for agricultural production detection. This study will provide an important guidance for nondestructive detecting the quality of stored-grain.


Asunto(s)
Espectroscopía de Terahertz , Triticum , Refractometría , Semillas
14.
Guang Pu Xue Yu Guang Pu Fen Xi ; 34(8): 2047-52, 2014 Aug.
Artículo en Zh | MEDLINE | ID: mdl-25474932

RESUMEN

With recent development of THz sources and detector, applications of THz radiation to nondestructive testing and quality control have expanded in many fields, such as agriculture, safety inspection and quality control, medicine, biochemistry, communication etc. Compared with other detection technique, being a new kind of technique, THz radiation has low energy, good perspectivity, and high signal-to-noise ratio, and thus can obtain physical, chemical and biological information. This paper first introduces the basic concept of THz radiation and the major properties, then gives an extensive review of recent research progress in detection of the quality of agricultural products via THz technique, analyzes the existing shortcomings of THz detection and discusses the outlook of potential application, finally proposes the new application of THz technique to detection of quality of stored grain.


Asunto(s)
Grano Comestible , Calidad de los Alimentos , Control de Calidad , Agricultura , Radiación Terahertz
15.
Micromachines (Basel) ; 15(3)2024 Feb 29.
Artículo en Inglés | MEDLINE | ID: mdl-38542603

RESUMEN

In order to enhance the sensitivity of wafer-level vacuum-packaged electric field sensors, this paper proposed a vertical-resonant MEMS electric field sensor based on TGV (Through Glass Via) technology. The microsensor is composed of the electric field sensing cover, the drive cover, and the SOI-based microstructures between them. TGV technology is innovatively used to fabricate the electric field sensing cover and the vertically-driven cover. The external electric field is concentrated and transmitted to the area below the silicon plate in the center of the electric field sensing cover through a metal plate and a metal pillar, reducing the coupling capacitance between the silicon plate and the packaging structure, thereby achieving the enhanced transmission of the electric field. The sensitivity-enhanced mechanism of the sensor is analyzed, and the key parameters of the sensor are optimized through finite element simulation. The fabrication process is designed and realized. A prototype is tested to characterize its performance. The experimental results indicate that the sensitivity of the sensor is 0.82 mV/(kV/m) within the electrostatic electric field ranging from 0-50 kV/m. The linearity of the sensor is 0.65%.

16.
Micromachines (Basel) ; 14(4)2023 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-37420972

RESUMEN

As a highly toxic heavy metal ion, mercury ion (Hg2+) pollution has caused serious harm to the environment and human health. In this paper, 4-mercaptopyridine (4-MPY) was selected as the sensing material and decorated on the surface of a gold electrode. Trace Hg2+ could be detected by both differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) methods. The proposed sensor displayed a wide detection range from 0.01 µg/L to 500 µg/L with a low limit of detection (LOD) of 0.002 µg/L by EIS measurements. Combined with molecular simulations and electrochemical analyses, the chelating mechanism between Hg2+ and 4-MPY was explored. Through the analysis of binding energy (BE) values and stability constants, 4-MPY showed an excellent selectivity for Hg2+. In the presence of Hg2+, the coordination of Hg2+ with the pyridine nitrogen of 4-MPY was generated at the sensing region, which caused a change in the electrochemical activity of the electrode surface. Due to the strong specific binding capability, the proposed sensor featured excellent selectivity and an anti-interference capability. Furthermore, the practicality of the sensor for Hg2+ detection was validated with the samples of tap water and pond water, which demonstrated its potential application for on-site environmental detection.

17.
Micromachines (Basel) ; 14(5)2023 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-37241526

RESUMEN

A highly sensitive and accurate dual-signal strategy is developed for trace Cu2+ detection based on the inner filter effect (IFE) between Tween 20-gold nanoparticles (AuNPs) and CdSe/ZnS quantum dots (QDs). Tween 20-AuNPs are utilized as colorimetric probes and excellent fluorescent absorbers. The fluorescence of CdSe/ZnS QDs can be quenched efficiently by Tween 20-AuNPs via IFE. In the presence of D-penicillamine, D-penicillamine induces the aggregation of Tween 20-AuNPs and the fluorescent recovery of CdSe/ZnS QDs at high ionic strength. Upon addition of Cu2+, D-penicillamine tends to selectively chelate with Cu2+ and then forms the mixed-valence complexes, which consequently inhibits the aggregation of Tween 20-AuNPs and the fluorescent recovery. The dual-signal method is used to quantitatively detect trace Cu2+, with low detection limits of 0.57 µg/L and 0.36 µg/L for colorimetry and fluorescence, respectively. In addition, the proposed method using a portable spectrometer is applied to the detection of Cu2+ in water. This sensitive, accurate and miniature sensing system has potential in environmental evaluations.

18.
Micromachines (Basel) ; 14(8)2023 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-37630029

RESUMEN

This paper proposes a highly sensitive and high-resolution resonant MEMS electrostatic field sensor based on electrostatic stiffness perturbation, which uses resonant frequency as an output signal to eliminate the feedthrough interference from the driving voltage. The sensor is composed of a resonator, driving electrode, detection electrode, transition electrode, and electrostatic field sensing plate. The working principle is that when there is an electrostatic field, an induction charge will appear at the surface of the electrostatic field sensing plate and induce electrostatic stiffness on the resonator, which will cause a resonant frequency shift. The resonant frequency is used as the output signal of the microsensor. The characteristics of the electrostatic field sensor are analyzed with a theoretical model and verified by finite element simulation. A device prototype is fabricated based on the Silicon on Insulator (SOI) process and tested under vacuum conditions. The results indicate that the sensitivity of the sensor is 0.1384Hz/(kV/m) and the resolution is better than 10 V/m.

19.
Sensors (Basel) ; 12(4): 5105-15, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22666077

RESUMEN

The steady-state zero output of static electric field measuring systems often fluctuates, which is caused mainly by the finite leakage resistance of the water film on the surface of the electric field microsensor package. The water adsorption has been calculated using the Boltzmann distribution equation at various relative humidities for borosilicate glass and polytetrafluoroethylene surfaces. At various humidities, water film thickness has been calculated, and the induced charge leakage and field attenuation have been theoretically investigated. Experiments have been performed with microsensors to verify the theoretical predictions and the results are in good agreement.

20.
Micromachines (Basel) ; 13(6)2022 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-35744542

RESUMEN

This paper proposes a novel wafer-level vacuum packaged electric field microsensor (EFM) featuring a high quality factor, low driving voltage, low noise, and low power consumption. The silicon-on-insulator (SOI) conductive handle layer was innovatively used as the sensing channel to transmit the external electric field to the surface of the sensitive structure, and the vacuum packaging was realized through anodic bonding between the SOI and glass-on-silicon (GOS). The fabrication process was designed and successfully realized, featured with a simplified process and highly efficient batch manufacturing, and the final chip size was only 5 × 5 mm. A theoretical model for the packaged device was set up. The influence of key parameters in the packaging structure on the output characteristics of the microsensor was analyzed on the basis of the proposed model. Experiments were conducted on the wafer-level vacuum-packaged EFM to characterize its performance. Experimental results show that, under the condition of applying 5 V DC driving voltage, the required AC driving voltage of the sensor was only 0.05 VP, and the feedthrough was only 4.2 mV. The quality factor was higher than 5000 and was maintained with no drop in the 50-day test. The vacuum in the chamber of the sensor was about 10 Pa. A sensitivity of 0.16 mV/(kV/m) was achieved within the electrostatic field range of 0-50 kV/m. The linearity of the microsensor was 1.62%, and the uncertainty was 4.42%.