Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Digit Imaging ; 34(1): 96-104, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33269449

RESUMEN

Several visual scoring methods are currently used to assess progression of rheumatoid arthritis (RA) on radiography. However, they are limited by its subjectivity and insufficient sensitivity. We have developed an original measurement system which uses a technique called phase-only correlation (POC). The purpose of this study is to validate the system by using a phantom simulating the joint of RA patients.A micrometer measurement apparatus that can adjust arbitrary joint space width (JSW) in a phantom joint was developed to define true JSW. The phantom was scanned with radiography, 320 multi detector CT (MDCT), high-resolution peripheral quantitative CT (HR-pQCT), cone beam CT (CBCT), and tomosynthesis. The width was adjusted to the average size of a women's metacarpophalangeal joint, from 1.2 to 2.2 mm with increments of 0.1 mm and 0.01 mm. Radiographical images were analyzed by the POC-based system and manual method, and images from various tomographical modalities were measured via the automatic margin detection method. Correlation coefficients between true JSW difference and measured JSW difference were all strong at 0.1 mm intervals with radiography (POC-based system and manual method), CBCT, 320MDCT, HR-pQCT, and tomosynthesis. At 0.01 mm intervals, radiography (POC-based system), 320MDCT, and HR-pQCT had strong correlations, while radiography (manual method) and CBCT had low correlations, and tomosynthesis had no statistically significant correlation. The smallest detectable changes for radiography (POC-based system), radiography (manual method), 320MDCT, HR-pQCT, CBCT, and tomosynthesis were 0.020 mm, 0.041 mm, 0.076 mm, 0.077 mm, 0.057 mm, and 0.087 mm, respectively. We conclude that radiography analyzed with the POC-based system might sensitively detect minute joint space changes of the finger joint.


Asunto(s)
Articulación Metacarpofalángica , Tomografía Computarizada por Rayos X , Femenino , Articulaciones de los Dedos , Humanos , Fantasmas de Imagen , Radiografía
2.
J Digit Imaging ; 30(3): 369-375, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28105533

RESUMEN

The purpose of the study is to validate the semi-automated method using tomosynthesis images for the assessment of finger joint space narrowing (JSN) in patients with rheumatoid arthritis (RA), by using the semi-quantitative scoring method as the reference standard. Twenty patients (14 females and 6 males) with RA were included in this retrospective study. All patients underwent radiography and tomosynthesis of the bilateral hand and wrist. Two rheumatologists and a radiologist independently scored JSN with two modalities according to the Sharp/van der Heijde score. Two observers independently measured joint space width on tomosynthesis images using an in-house semi-automated method. More joints with JSN were revealed with tomosynthesis score (243 joints) and the semi-automated method (215 joints) than with radiography (120 joints), and the associations between tomosynthesis scores and radiography scores were demonstrated (P < 0.001). There was significant, negative correlation between measured joint space width and tomosynthesis scores with r = -0.606 (P < 0.001) in metacarpophalangeal joints and r = -0.518 (P < 0.001) in proximal interphalangeal joints. Inter-observer and intra-observer agreement of the semi-automated method using tomosynthesis images was in almost perfect agreement with intra-class correlation coefficient (ICC) values of 0.964 and 0.963, respectively. The semi-automated method using tomosynthesis images provided sensitive, quantitative, and reproducible measurement of finger joint space in patients with RA.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Articulaciones de los Dedos/diagnóstico por imagen , Articulación Metacarpofalángica/diagnóstico por imagen , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
3.
Knee Surg Sports Traumatol Arthrosc ; 18(9): 1176-83, 2010 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-20012014

RESUMEN

It is difficult to precisely identify the locations of tunnels after double-bundle anterior cruciate ligament (ACL) reconstruction postoperatively. Using our novel transparent 3-dimensional computed tomography (T-3DCT), we evaluated intra-articular outlet locations and the angles of the anteromedial (AM) and posterolateral (PL) tunnels after anatomic double-bundle ACL reconstruction using the trans-tibial technique. A prospective study was performed with 123 consecutive patients. Tunnel outlet locations were identified on T-3DCT images showing the true lateral view of the femur and indicated by our originally defined X, Y coordinates. We also determined the angles between the tunnel axis and a joint surface line in the coronal plane, the long axis of the femur in the sagittal plane, and the posterior condyle line in the axial plane of both the femur and the tibia. The mean X, Y coordinates of the AM and PL tunnel outlets were 21, 43% and 0, 33%, respectively. In the coronal, sagittal, and axial planes, the mean AM femoral tunnel angles were 63 degrees, 48 degrees, and 55 degrees, respectively; the mean AM tibial tunnel angles in the tibia were 63 degrees, 49 degrees, and 71 degrees, respectively; the mean PL femoral tunnel angles were 38 degrees, 58 degrees, and 43 degrees, respectively; and the mean PL tibial tunnel angles were 46 degrees, 53 degrees, and 45 degrees, respectively. The AM and PL tunnel outlets and angles could be detailed precisely in three dimensions by using T-3DCT. This imaging technique may be useful to confirm surgical techniques and to improve clinical outcomes.


Asunto(s)
Ligamento Cruzado Anterior/diagnóstico por imagen , Artroscopía/métodos , Fémur/diagnóstico por imagen , Radiografía Intervencional/métodos , Tibia/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Ligamento Cruzado Anterior/anatomía & histología , Ligamento Cruzado Anterior/cirugía , Femenino , Fémur/anatomía & histología , Humanos , Articulación de la Rodilla/anatomía & histología , Articulación de la Rodilla/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Tendones/trasplante , Tibia/anatomía & histología , Tibia/cirugía , Adulto Joven
4.
Sci Rep ; 9(1): 8526, 2019 06 12.
Artículo en Inglés | MEDLINE | ID: mdl-31189913

RESUMEN

The visual assessment of joint space narrowing (JSN) on radiographs of rheumatoid arthritis (RA) patients such as the Genant-modified Sharp score (GSS) is widely accepted but limited by its subjectivity and insufficient sensitivity. We developed a software application which can assess JSN quantitatively using a temporal subtraction technique for radiographs, in which the chronological change in JSN between two radiographs was defined as the joint space difference index (JSDI). The aim of this study is to prove the superiority of the software in terms of detecting fine radiographic progression in finger JSN over human observers. A micrometer measurement apparatus that can adjust arbitrary joint space width (JSW) in a phantom joint was developed to define true JSW. We compared the smallest detectable changes in JSW between the JSDI and visual assessment using phantom images. In a clinical study, 222 finger joints without interval score change on GSS in 15 RA patients were examined. We compared the JSDI between joints with and without synovial vascularity (SV) on power Doppler ultrasonography during the follow-up period. True JSW difference was correlated with JSDI for JSW differences ranging from 0.10 to 1.00 mm at increments of 0.10 mm (R2 = 0.986 and P < 0.001). Rheumatologists were difficult to detect JSW difference of 0.30 mm or less. The JSDI of finger joints with SV was significantly higher than those without SV (P = 0.030). The software can detect fine differences in JSW that are visually unrecognizable.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Articulaciones de los Dedos/diagnóstico por imagen , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador , Programas Informáticos , Adulto , Anciano , Progresión de la Enfermedad , Humanos , Masculino , Persona de Mediana Edad
5.
Radiol Phys Technol ; 9(1): 6-14, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26092218

RESUMEN

Rheumatoid arthritis (RA) is a systemic disease that is caused by autoimmunity. RA causes synovial proliferation, which may result in bone erosion and joint space narrowing in the affected joint. Tomosynthesis is a promising modality which may detect early bone lesions such as small bone erosion and slight joint space narrowing. Nevertheless, so far, the optimal reconstruction filter for detection of early bone lesions of fingers on tomosynthesis has not yet been known. Our purpose in this study was to determine an optimal reconstruction filter setting by using a bone phantom. We obtained images of a cylindrical phantom with holes simulating bone erosions (diameters of 0.6, 0.8, 1.0, 1.2, and 1.4 mm) and joint spaces by aligning two phantoms (space widths from 0.5 to 5.0 mm with 0.5 mm intervals), examining six reconstruction filters by using tomosynthesis. We carried out an accuracy test of the bone erosion size and joint space width, done by one radiological technologist, and a test to assess the visibility of bone erosion, done by five radiological technologists. No statistically significant difference was observed in the measured bone erosion size and joint space width among all of the reconstruction filters. In the visibility assessment test, reconstruction filters of Thickness+- and Thickness-- were among the best statistically in all characteristics except the signal-to-noise ratio. The Thickness+- and Thickness-- reconstruction filter may be optimal for evaluation of RA bone lesions of small joints in tomosynthesis.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Falanges de los Dedos de la Mano/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/instrumentación , Fantasmas de Imagen , Intensificación de Imagen Radiográfica , Humanos , Relación Señal-Ruido
6.
Br J Radiol ; 89(1062): 20150967, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27043764

RESUMEN

OBJECTIVE: Accurate evaluation of joint space width (JSW) is important in the assessment of rheumatoid arthritis (RA). In clinical radiography of bilateral hands, the oblique incidence of X-rays is unavoidable, which may cause perceptional or measurement error of JSW. The objective of this study was to examine whether tomosynthesis, a recently developed modality, can facilitate a more accurate evaluation of JSW than radiography under the condition of oblique incidence of X-rays. METHODS: We investigated quantitative errors derived from the oblique incidence of X-rays by imaging phantoms simulating various finger joint spaces using radiographs and tomosynthesis images. We then compared the qualitative results of the modified total Sharp score of a total of 320 joints from 20 patients with RA between these modalities. RESULTS: A quantitative error was prominent when the location of the phantom was shifted along the JSW direction. Modified total Sharp scores of tomosynthesis images were significantly higher than those of radiography, that is to say JSW was regarded as narrower in tomosynthesis than in radiography when finger joints were located where the oblique incidence of X-rays is expected in the JSW direction. CONCLUSION: Tomosynthesis can facilitate accurate evaluation of JSW in finger joints of patients with RA, even with oblique incidence of X-rays. ADVANCES IN KNOWLEDGE: Accurate evaluation of JSW is necessary for the management of patients with RA. Through phantom and clinical studies, we demonstrate that tomosynthesis may achieve more accurate evaluation of JSW.


Asunto(s)
Artritis Reumatoide/diagnóstico por imagen , Articulaciones de los Dedos/diagnóstico por imagen , Posicionamiento del Paciente/métodos , Intensificación de Imagen Radiográfica/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Artrografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA