Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Anal Chem ; 95(12): 5331-5339, 2023 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-36926822

RESUMEN

As an enzyme-free exponential nucleic acid amplification method, the click chemistry-mediated ligation chain reaction (ccLCR) has shown great prospects in the molecular diagnosis. However, the current optics-based ccLCR is challenged by remarkable nonspecific amplification, severely hindering its future application. This study demonstrated that the severe nonspecific amplification was generated probably due to high random collision in the high DNA probe concentration (µM level). To solve this hurdle, a nucleic acid template-dominated ccLCR was constructed using nM-level DNA probes and read on an electrochemical platform (cc-eLCR). Under the optimal conditions, the proposed cc-eLCR detected a low-level nucleic acid target (1 fM) with a single-base resolution. Furthermore, this assay was applied to detect the target of interest in cell extracts with a satisfactory result. The proposed cc-eLCR offers huge possibility for click chemistry-mediated enzyme-free exponential nucleic acid amplification in the application of medical diagnosis and biomedical research.


Asunto(s)
Técnicas Biosensibles , ARN , Química Clic/métodos , Técnicas Biosensibles/métodos , ADN/química , Sondas de ADN/genética , Sondas de ADN/química , Técnicas de Amplificación de Ácido Nucleico/métodos , Técnicas Electroquímicas/métodos , Límite de Detección , Hibridación de Ácido Nucleico
2.
Anal Chem ; 93(2): 911-919, 2021 01 19.
Artículo en Inglés | MEDLINE | ID: mdl-33284015

RESUMEN

Accurate and sensitive detection of single-base mutations in RNAs is of great value in basic studies of life science and medical diagnostics. However, the current available RNA detection methods are challenged by heterogeneous clinical samples in which trace RNA mutants usually existed in a large pool of normal wild sequences. Thus, there is still great need for developing the highly sensitive and highly specific methods in detecting single-base mutations of RNAs in heterogeneous clinical samples. In the present study, a new chimeric DNA probe-aided ligase chain reaction-based electrochemical method (cmDNA-eLCR) was developed for RNA mutation detection through the BSA-based carrier platform and the horseradish peroxidase-hydrogen peroxide-tetramethylbenzidine (HRP-H2O2-TMB) system. The denaturing polyacrylamide gel electrophoresis and a fluorophore-labeled probe was ingeniously designed to demonstrate the advantage of cmDNA in ligation to normal DNA templated by RNA with the catalysis of T4 RNA ligase 2 as well as its higher selectivity than DNA ligase system. Finally, the proposed cmDNA-eLCR, compared with the traditional eLCR, showed excellent performance in discriminating single base-mismatched sequences, where the signal response for mismatched targets at a high concentration could overlap completely with that for the blank control. Besides, this cmDNA-eLCR assay had a wide linear range crossing six orders of magnitude from 1.0 × 10-15 to1.0 × 10-10 M with a limit of detection as low as 0.6 fM. Furthermore, this assay was applied to detect RNA in real sample with a satisfactory result, thereby demonstrating its great potential in diagnosis of RNA-related diseases.


Asunto(s)
Técnicas Biosensibles , Sondas de ADN/química , Técnicas Electroquímicas , Reacción en Cadena de la Ligasa , ARN/genética , Humanos
3.
Anal Chem ; 91(7): 4552-4558, 2019 04 02.
Artículo en Inglés | MEDLINE | ID: mdl-30838849

RESUMEN

As an alternative to most of the reported nucleic acid amplification-based electrochemical DNA biosensors used for detection of trace levels of genomic DNA, we herein present a novel detection concept. The proposed system involves the conversion of two short double-stranded DNAs (dsDNAs), labeled with a thiol-tag or biotin-tag, into a single integrated dsDNA containing thiol and biotin at both terminals in the presence of target DNA through ligase chain reaction (LCR) and followed by the immobilization of these integrated dsDNAs on a bovine serum albumin (BSA)-modified gold electrode surface. Owing to rapid depletion of the two short dsDNAs via LCR, the integrated dsDNAs were generated in an exponential manner so that this sensoring approach offered a limit of detection of 25 yoctomoles (15 copies in 50 µL sample volumes), a high discrimination of single-base mismatch and a wide linear concentration range (across 6 orders of magnitude) for target DNA. Significantly, the proposed sensor, which has simplicity in operation and ease of miniaturization, detected the target of interest in total nucleic acid extracts derived from clinical serum samples with excellent results, thereby demonstrating its considerable diagnostic potential in fields ranging from virus detection to the diagnosis of genetic diseases.


Asunto(s)
Técnicas Biosensibles/métodos , ADN/sangre , Genoma Humano , Animales , Bovinos , ADN/metabolismo , Técnicas Electroquímicas , Electrodos , Oro/química , Humanos , Técnicas de Amplificación de Ácido Nucleico , Polimorfismo de Nucleótido Simple , Albúmina Sérica Bovina/química
4.
Talanta ; 216: 120966, 2020 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-32456905

RESUMEN

Challenged by the detection of trace amounts of mutants and disturbance from endogenous substances in clinical samples, herein, we present a novel electrochemical biosensor based on ligase chain reaction (eLCR) via the thermostable ligase with high mutation recognizing ability. The lengthened double-stranded DNAs exponentially generated via LCR were uniformly distributed on a bovine serum albumin-modified gold electrode, in which the phosphate buffer was tactfully added to remove adsorbed uninterested-probes, and thereafter the amperometry current was collected for the specific binding of streptavidin-poly-HRP and subsequent catalysis in the 3, 3', 5, 5'-tetramethylbenzidine substrate that contained hydrogen peroxide. It found that, under optimized conditions, the proposed biosensor exhibited a high selectivity of mutant targets from the 104-fold excess of co-existent wild targets within a detection limit of 0.5 fM. Impressively, without the involvement of pre-PCR, the homozygous mutants were specifically distinguished from the wild genotype of CYP2C19*2 allele in human whole blood samples. Therefore, the proposed eLCR, due to its advantages in simple primer design, operational ease and ease of miniaturization, has demonstrated its considerable potential for point-of-care testing in the diagnosis of point mutation-related diseases and personalized medicine.


Asunto(s)
Técnicas Biosensibles , Citocromo P-450 CYP2C19/genética , Técnicas Electroquímicas , Reacción en Cadena de la Ligasa , Citocromo P-450 CYP2C19/sangre , Humanos , Mutación Puntual
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA