Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 363
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
N Engl J Med ; 2024 Aug 31.
Artículo en Inglés | MEDLINE | ID: mdl-39216092

RESUMEN

BACKGROUND: Whether transcatheter mitral-valve repair improves outcomes in patients with heart failure and functional mitral regurgitation is uncertain. METHODS: We conducted a randomized, controlled trial involving patients with heart failure and moderate to severe functional mitral regurgitation from 30 sites in nine countries. The patients were assigned in a 1:1 ratio to either transcatheter mitral-valve repair and guideline-recommended medical therapy (device group) or medical therapy alone (control group). The three primary end points were the rate of the composite of first or recurrent hospitalization for heart failure or cardiovascular death during 24 months; the rate of first or recurrent hospitalization for heart failure during 24 months; and the change from baseline to 12 months in the score on the Kansas City Cardiomyopathy Questionnaire-Overall Summary (KCCQ-OS; scores range from 0 to 100, with higher scores indicating better health status). RESULTS: A total of 505 patients underwent randomization: 250 were assigned to the device group and 255 to the control group. At 24 months, the rate of first or recurrent hospitalization for heart failure or cardiovascular death was 37.0 events per 100 patient-years in the device group and 58.9 events per 100 patient-years in the control group (rate ratio, 0.64; 95% confidence interval [CI], 0.48 to 0.85; P = 0.002). The rate of first or recurrent hospitalization for heart failure was 26.9 events per 100 patient-years in the device group and 46.6 events per 100 patient-years in the control group (rate ratio, 0.59; 95% CI, 0.42 to 0.82; P = 0.002). The KCCQ-OS score increased by a mean (±SD) of 21.6±26.9 points in the device group and 8.0±24.5 points in the control group (mean difference, 10.9 points; 95% CI, 6.8 to 15.0; P<0.001). Device-specific safety events occurred in 4 patients (1.6%). CONCLUSIONS: Among patients with heart failure with moderate to severe functional mitral regurgitation who received medical therapy, the addition of transcatheter mitral-valve repair led to a lower rate of first or recurrent hospitalization for heart failure or cardiovascular death and a lower rate of first or recurrent hospitalization for heart failure at 24 months and better health status at 12 months than medical therapy alone. (Funded by Abbott Laboratories; RESHAPE-HF2 ClinicalTrials.gov number, NCT02444338.).

2.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38096587

RESUMEN

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Asunto(s)
Desfibriladores Implantables , Marcapaso Artificial , Cardiopatía Reumática , Insuficiencia de la Válvula Tricúspide , Humanos , Marcapaso Artificial/efectos adversos , Desfibriladores Implantables/efectos adversos , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/complicaciones , Cardiopatía Reumática/complicaciones , Estudios Retrospectivos
3.
Eur Heart J ; 45(8): 586-597, 2024 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-37624856

RESUMEN

BACKGROUND AND AIMS: Benefit of tricuspid regurgitation (TR) correction and timing of intervention are unclear. This study aimed to compare survival rates after surgical or transcatheter intervention to conservative management according to a TR clinical stage as assessed using the TRI-SCORE. METHODS: A total of 2,413 patients with severe isolated functional TR were enrolled in TRIGISTRY (1217 conservatively managed, 551 isolated tricuspid valve surgery, and 645 transcatheter valve repair). The primary endpoint was survival at 2 years. RESULTS: The TRI-SCORE was low (≤3) in 32%, intermediate (4-5) in 33%, and high (≥6) in 35%. A successful correction was achieved in 97% and 65% of patients in the surgical and transcatheter groups, respectively. Survival rates decreased with the TRI-SCORE in the three treatment groups (all P < .0001). In the low TRI-SCORE category, survival rates were higher in the surgical and transcatheter groups than in the conservative management group (93%, 87%, and 79%, respectively, P = .0002). In the intermediate category, no significant difference between groups was observed overall (80%, 71%, and 71%, respectively, P = .13) but benefit of the intervention became significant when the analysis was restricted to patients with successful correction (80%, 81%, and 71%, respectively, P = .009). In the high TRI-SCORE category, survival was not different to conservative management in the surgical and successful repair group (61% and 68% vs 58%, P = .26 and P = .18 respectively). CONCLUSIONS: Survival progressively decreased with the TRI-SCORE irrespective of treatment modality. Compared to conservative management, an early and successful surgical or transcatheter intervention improved 2-year survival in patients at low and, to a lower extent, intermediate TRI-SCORE, while no benefit was observed in the high TRI-SCORE category.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Resultado del Tratamiento , Cateterismo Cardíaco
4.
Basic Res Cardiol ; 2024 Oct 18.
Artículo en Inglés | MEDLINE | ID: mdl-39422732

RESUMEN

Numerous cardioprotective interventions have been reported to reduce myocardial infarct size (IS) in pre-clinical studies. However, their translation for the benefit of patients with acute myocardial infarction (AMI) has been largely disappointing. One reason for the lack of translation is the lack of rigor and reproducibility in pre-clinical studies. To address this, we have established the European IMproving Preclinical Assessment of Cardioprotective Therapies (IMPACT) pig AMI network with centralized randomization and blinded core laboratory IS analysis and validated the network with ischemic preconditioning (IPC) as a positive control. Ten sites in the COST Innovators Grant (IG16225) network participated in the IMPACT network. Three sites were excluded from the final analysis through quality control of infarct images and use of pre-defined exclusion criteria. Using a centrally generated randomization list, pigs were allocated to myocardial ischemia/reperfusion (I/R, N = 5/site) or IPC + I/R (N = 5/site). The primary endpoint was IS [% area-at-risk (AAR)], as quantified by triphenyl-tetrazolium-chloride (TTC) staining in a centralized, blinded core laboratory (5 sites), or IS [% left-ventricular mass (LV)], as quantified by a centralized, blinded cardiac magnetic resonance (CMR) core laboratory (2 sites). In pooled analyses, IPC significantly reduced IS when compared to I/R (57 ± 14 versus 32 ± 19 [%AAR] N = 25 pigs/group; p < 0.001; 25 ± 13 versus 14 ± 8 [%LV]; N = 10 pigs/group; p = 0.021). In site-specific analyses, in 4 of the 5 sites, IS was significantly reduced by IPC when compared to I/R when quantified by TTC and in 1 of 2 sites when quantified by CMR. A pig AMI multicenter European network with centralized randomization and core blinded IS analysis was established and validated with the aim to improve the reproducibility of cardioprotective interventions in pre-clinical studies and the translation of cardioprotection for patient benefit.

5.
J Cardiovasc Electrophysiol ; 35(10): 2071-2075, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39138830

RESUMEN

INTRODUCTION: Pulsed-field ablation (PFA) is a novel nonthermal energy that shows unique features that can be of use beyond pulmonary vein ablation, like tissue selectivity or proximity rather than contact dependency. METHODS AND RESULTS: We report three cases of right focal atrial tachycardias arising from the superior cavoatrial junction and the crista terminalis, in close relationship with the phrenic nerve, effectively ablated using a commercially available PFA catheter designed for pulmonary vein isolation without collateral damage. CONCLUSION: PFA can be useful for treating right atrial tachycardias involving sites near the phrenic nerve, avoiding the need for complex nerve-sparing strategies.


Asunto(s)
Electroporación , Nervio Frénico , Humanos , Nervio Frénico/fisiopatología , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Femenino , Taquicardia Supraventricular/cirugía , Taquicardia Supraventricular/fisiopatología , Taquicardia Supraventricular/diagnóstico , Frecuencia Cardíaca , Anciano , Ablación por Catéter , Técnicas Electrofisiológicas Cardíacas , Potenciales de Acción , Catéteres Cardíacos
6.
Eur J Clin Invest ; 54(9): e14241, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38767226

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is increasingly being used in younger patients and those with lower peri-procedural risk, meaning more patients will live long enough to experience structural valve deterioration (SVD) of the bioprosthesis, indicating repeated TAVI. Experience of repeated TAVI-transcatheter heart valve (THV) implantation into an index THV is limited. This registry aims to assess the peri-procedural and short-term safety, efficacy and durability of repeated TAVI. METHODS: The ReTAVI Prospective observational registry is an investigator-initiated, multicentre, international, prospective registry of patients undergoing repeated TAVI using balloon-expandable SAPIEN prosthesis to evaluate procedural and short-term safety, efficacy and durability as well as anatomical and procedural factors associated with optimal results. The registry will enrol at least 150 patients across 60 high-volume centres. Patients must be ≥18 years old, have had procedural success with their first TAVI, have index THV device failure, intend to undergo repeated TAVI and be considered suitable candidates by their local Heart Team. All patients will undergo a 30-day and 12-month follow-up. The estimated study completion is 2025. CONCLUSIONS: The registry will collect pre-, peri-, postoperative and 12-months data on patients undergoing repeated TAVI procedures with THVs for failure of the index THV and determine VARC-3-defined efficacy and safety at 30 days and functional outcome at 12 months. The registry will expand existing data sets and identify patient characteristics/indicators related to complications and clinical benefits for patients with symptomatic severe calcific degenerative aortic stenosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estenosis de la Válvula Aórtica/cirugía , Estudios Prospectivos , Resultado del Tratamiento , Prótesis Valvulares Cardíacas , Falla de Prótesis , Masculino , Anciano
7.
Eur Heart J ; 44(2): 142-158, 2023 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-36452988

RESUMEN

BACKGROUND: The prospective, multicentre EURECA registry assessed the use of imaging and adoption of the European Society of Cardiology (ESC) Guidelines (GL) in patients with chronic coronary syndromes (CCS). METHODS: Between May 2019 and March 2020, 5156 patients were recruited in 73 centres from 24 ESC member countries. The adoption of GL recommendations was evaluated according to clinical presentation and pre-test probability (PTP) of obstructive coronary artery disease (CAD). RESULTS: The mean age of the population was 64 ± 11 years, 60% of patients were males, 42% had PTP >15%, 27% had previous CAD, and ejection fraction was <50% in 5%. Exercise ECG was performed in 32% of patients, stress imaging as the first choice in 40%, and computed tomography coronary angiography (CTCA) in 22%. Invasive coronary angiography (ICA) was the first or downstream test in 17% and 11%, respectively. Obstructive CAD was documented in 24% of patients, inducible ischaemia in 19%, and 13% of patients underwent revascularization. In 44% of patients, the overall diagnostic process did not adopt the GL. In these patients, referral to stress imaging (21% vs. 58%; P < 0.001) or CTCA (17% vs. 30%; P < 0.001) was less frequent, while exercise ECG (43% vs. 22%; P < 0.001) and ICA (48% vs. 15%; P < 0.001) were more frequently performed. The adoption of GL was associated with fewer ICA, higher proportion of diagnosis of obstructive CAD (60% vs. 39%, P < 0.001) and revascularization (54% vs. 37%, P < 0.001), higher quality of life, fewer additional testing, and longer times to late revascularization. CONCLUSIONS: In patients with CCS, current clinical practice does not adopt GL recommendations on the use of diagnostic tests in a significant proportion of patients. When the diagnostic approach adopts GL recommendations, invasive procedures are less frequently used and the diagnostic yield and therapeutic utility are superior.


Asunto(s)
Enfermedad de la Arteria Coronaria , Calidad de Vida , Masculino , Humanos , Persona de Mediana Edad , Anciano , Femenino , Angiografía Coronaria/métodos , Estudios Prospectivos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Tomografía Computarizada por Rayos X/métodos , Angiografía por Tomografía Computarizada , Valor Predictivo de las Pruebas
8.
Int J Mol Sci ; 25(18)2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39337378

RESUMEN

Vascular aging is associated with the development of cardiovascular complications, in which endothelial cell senescence (ES) may play a critical role. Nitric oxide (NO) prevents human ES through inhibition of oxidative stress, and inflammatory signaling by mechanisms yet to be elucidated. Endothelial cells undergo an irreversible growth arrest and alter their functional state after a finite number of divisions, a phenomenon called replicative senescence. We assessed the contribution of NO during replicative senescence of human aortic (HAEC) and coronary (CAEC) endothelial cells, in which accumulation of the senescence marker SA-ß-Gal was quantified by ß-galactosidase staining on cultured cells. We found a negative correlation in passaged cell cultures from P0 to P12, between a reduction in NO production with increased ES and the formation of reactive oxygen (ROS) and nitrogen (ONOO-) species, indicative of oxidative and nitrosative stress. The effect of ES was evidenced by reduced expression of endothelial Nitric Oxide Synthase (eNOS), Interleukin Linked Kinase (ILK), and Heat shock protein 90 (Hsp90), alongside a significant increase in the BH2/BH4 ratio, inducing the uncoupling of eNOS, favoring the production of superoxide and peroxynitrite species, and fostering an inflammatory environment, as confirmed by the levels of Cyclophilin A (CypA) and its receptor Extracellular Matrix Metalloprotease Inducer (EMMPRIN). NO prevents ES by preventing the uncoupling of eNOS, in which oxidation of BH4, which plays a key role in eNOS producing NO, may play a critical role in launching the release of free radical species, triggering an aging-related inflammatory response.


Asunto(s)
Senescencia Celular , Células Endoteliales , Óxido Nítrico Sintasa de Tipo III , Óxido Nítrico , Estrés Oxidativo , Humanos , Óxido Nítrico Sintasa de Tipo III/metabolismo , Células Endoteliales/metabolismo , Óxido Nítrico/metabolismo , Especies Reactivas de Oxígeno/metabolismo , Células Cultivadas , Aorta/metabolismo , Aorta/citología
9.
J Cardiovasc Electrophysiol ; 34(2): 356-365, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36434798

RESUMEN

INTRODUCTION: Critical isthmuses of atypical atrial flutters (AAFLs) are usually located at slow conduction areas that exhibit fractionated electrograms. We tested a novel software, intended for integration with a commercially available navigation system, that automatically detects fractionated electrograms, to identify the critical isthmus in patients with AAFL ablation. METHODS AND RESULTS: All available patients were analyzed; 27 patients with 33 AAFLs were included. The PentaRay NAV catheter (Biosense Webster) was used for mapping. The novel software was retrospectively applied; fractionated points with duration ≥80 ms and bipolar voltage between 0.05 and 0.5 mV were highlighted on the surface of maps. In 10 randomly chosen AAFLs, an expert electrophysiologist evaluated the positive predictive value of the algorithm to detect true fractionation: 74.4%. We tested the capacity of the software to identify areas of fractionation (defined as clusters of ≥3 adjacent points with fractionation) at the critical isthmus of the AAFLs (defined using conventional mapping criteria). An area of fractionation was identified at the critical isthmus in 30 cases (91%). Globally, 144 areas of fractionation (median number per AAFL 4 [3-6]) were identified. Duration of the fractionation or the surface of the areas was not different between areas at critical isthmuses and the rest. Setting the fractionation score filter of the software in nine provided best performance. CONCLUSIONS: The novel software detected areas of fractionation at the critical isthmus in most AAFLs, which may help identify the critical isthmus in clinical practice.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Humanos , Estudios Retrospectivos , Ablación por Catéter/métodos , Frecuencia Cardíaca , Valor Predictivo de las Pruebas
10.
Eur J Clin Invest ; 53(4): e13935, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36504276

RESUMEN

BACKGROUND: Although cardiac resynchronization therapy (CRT) is beneficial in most heart failure patients, up to 40% do not respond to CRT. It has been suggested that multipoint left ventricle pacing (MPP) would increase the response rate. AIM: To assess the CRT response rate at 6 months in patients implanted with a CRT device with the MPP feature activated early after the implant. METHODS: This was a multicentre, prospective, open-label and non-randomized study. The primary endpoint was response to biventricular pacing defined as >15% relative reduction in left ventricular end-systolic volume (LVESV) comparing echocardiography measurements performed at baseline and 6 months by a core laboratory. Among secondary endpoints the combined endpoint of mortality or all-cause hospitalizations was evaluated. Primary study endpoint and clinical outcomes were compared to a Quarto II control cohort. RESULTS: Totally, 105 patients were included. The response rate was 64.6% (97.5% lower confidence bound 53%). Mean relative reduction in LVESV was 25.3%, and mean absolute increase in LVEF was 9.4%. The subjects with device programmed using anatomical approach showed a trend towards higher responder rate than those using the electrical approach (72% vs. 61.1%, p = 0.32). Finally, the combined incidence of mortality and or all-cause hospitalizations at 6 month was 12.4%. CONCLUSIONS: Early activation of MPP was not associated to an advantage increasing echocardiography responders to CRT at 6 months of follow-up. Nevertheless, patients programmed using widest pacing cathodes had a numerically higher responder rate. Finally, early activation of MPP was associated to a low incidence of clinical endpoints at 6 months of follow-up.


Asunto(s)
Terapia de Resincronización Cardíaca , Insuficiencia Cardíaca , Humanos , Estudios Prospectivos , Función Ventricular Izquierda/fisiología , Volumen Sistólico/fisiología , Resultado del Tratamiento , Dispositivos de Terapia de Resincronización Cardíaca
11.
Catheter Cardiovasc Interv ; 102(3): 547-557, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37431253

RESUMEN

Transcatheter aortic valve implantation (TAVI) is recommended for a growing range of patients with severe aortic stenosis in the European Society of Cardiology and European Association for Cardio-Thoracic Surgery (ESC/EACTS) 2021 Guidelines update. However, guideline implementation programs are needed to ensure the application of clinical recommendations which will favorably influence disease outcomes. An Expert Council was convened to identify whether cardiology services across Europe are set up to address the growing needs of patients with severe aortic stenosis for increased access to TAVI by identifying the key challenges faced in growing TAVI programs and mapping associated solutions. Wide variation exists across Europe in terms of TAVI availability and capacity to deliver the increased demand for TAVI in different countries. The recommendations of this Expert Council focus on the short-to-medium-term aspects where the most immediate, actionable impact can be achieved. The focus on improving procedural efficiency and optimizing the patient pathway via clinical practice and patient management demonstrates how to mitigate the current major issues of shortfall in catheterization laboratory, workforce, and bed capacity. Procedural efficiencies may be achieved through steps including streamlined patient assessment, the benchmarking of standards for minimalist procedures, standardized approaches around patient monitoring and conduction issues, and the implementation of nurse specialists and dedicated TAVI coordinators to manage organization, logistics, and early mobilization. Increased collaboration with wider stakeholders within institutions will support successful TAVI uptake and improve patient and economic outcomes. Further, increased education, collaboration, and partnership between cardiology centers will facilitate sharing of expertise and best clinical practice.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Europa (Continente) , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
12.
Echocardiography ; 40(8): 775-783, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37351556

RESUMEN

AIM: we sought to test the inter-center reproducibility of 16 echo laboratories involved in the EACVI-Afib Echo Europe. METHODS: This was done on a dedicated setting of 10 patients with sinus rhythm (SR) and 10 with persistent atrial fibrillation (AF), collected by the Principal Investigator. Images and loops of echo-exams were stored and made available for labs. The tested measurements included main echo-Doppler parameters, global longitudinal strain (GLS) and peak atrial longitudinal strain (PALS). RESULTS: Single measures interclass correlation coefficients (ICCs) of left ventricular mass and ejection fraction were suboptimal in both patients with SR and AF. Among diastolic parameters, ICCs of deceleration time were poor, in particular in AF (=.50). ICCs of left atrial size and function, besides optimal in AF, showed an acceptable despite moderate concordance in SR. ICC of GLS was .81 and .78 in SR and AF respectively. ICCs of PALS were suitable but lower in 4-chamber than in 2-chamber view. By depicting the boxplot of the 16 laboratories, GLS distribution was completely homogeneous in SR, whereas GLS of AF and PALS of both SR and AF presented a limited number of outliers. GLS mean ± SE of the 16 labs was 19.7 ± .36 (95% CI: 18.8-20.4) in SR and 16.5 ± .29 (95% CI: 15.9-17.1) in AF, whereas PALS mean ± SE was 43.8 ± .70 (95% CI: 42.3-45.3) and 10.2 ± .32 (95% CI: 9.5-10.9) respectively. CONCLUSION: While the utilization of some standard-echo variables should be discouraged in registries, the application of GLS and PALS could be largely promoted because their superior reproducibility, even in AF.


Asunto(s)
Fibrilación Atrial , Humanos , Reproducibilidad de los Resultados , Ecocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen , Sistema de Registros
13.
J Cardiovasc Electrophysiol ; 33(12): 2528-2537, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36116038

RESUMEN

INTRODUCTION: High-power short-duration (HPSD) has been proposed to shorten procedure times while maintaining efficacy and safety. We evaluated the differences in size and geometry between radiofrequency lesions obtained with this method and conventional ones. METHODS AND RESULTS: Twenty-eight sets of 10 perpendicular radiofrequency applications were performed with two commercially available catheters: a temperature-controlled HPSD catheter (QDot-Micro) and a conventional power-controlled catheter (Thermocool SmartTouch) on porcine left ventricle. Different power settings (35, 40, 50, and 90 W), contact force (CF; 10 and 20 g), ablation index (AI; 400 and 550), and application times were combined to create conventional (35-40 W), HPSD (50 W) and very-high-power short-duration (VHPSD; 90 W) lesions, that were cross-sectioned and measured. About 4-s VHPSD lesions were smaller, shallower, and thinner than HPSD performed with the QDot-Micro catheter in any scenario of CF or AI (61 ± 7.8 mm3 , 6.1 ± 0.3 mm wide, and 2.9 ± 0.1 mm deep with 10 g; 72.2 ± 0.5 mm3 , 6.8 ± 0.3 mm wide, and 2.9 ± 0.2 mm deep with 20 g). Conventional and HPSD lesions performed with the temperature-controlled catheter were generally bigger, deeper, and wider than the ones obtained with the power-controlled catheter, as well as more consistent in size. This was especially true with the lower CF and AI scenario, while differences were less notable with other setting combinations. CONCLUSION: VHPSD lesions performed with QDot-Micro catheter were smaller than any other lesions, which is especially attractive for posterior left atrial wall ablation. On the contrary, conventional-powered and HPSD lesions performed with this catheter were equally sized (or even bigger with lower CF and AI objectives), as well as more consistent in size, which would guarantee transmurality in other locations.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Porcinos , Animales , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Temperatura , Catéteres , Resultado del Tratamiento
14.
Eur Heart J ; 42(13): 1254-1269, 2021 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-33734354

RESUMEN

Secondary (or functional) mitral regurgitation (SMR) occurs frequently in chronic heart failure (HF) with reduced left ventricular (LV) ejection fraction, resulting from LV remodelling that prevents coaptation of the valve leaflets. Secondary mitral regurgitation contributes to progression of the symptoms and signs of HF and confers worse prognosis. The management of HF patients with SMR is complex and requires timely referral to a multidisciplinary Heart Team. Optimization of pharmacological and device therapy according to guideline recommendations is crucial. Further management requires careful clinical and imaging assessment, addressing the anatomical and functional features of the mitral valve and left ventricle, overall HF status, and relevant comorbidities. Evidence concerning surgical correction of SMR is sparse and it is doubtful whether this approach improves prognosis. Transcatheter repair has emerged as a promising alternative, but the conflicting results of current randomized trials require careful interpretation. This collaborative position statement, developed by four key associations of the European Society of Cardiology-the Heart Failure Association (HFA), European Association of Percutaneous Cardiovascular Interventions (EAPCI), European Association of Cardiovascular Imaging (EACVI), and European Heart Rhythm Association (EHRA)-presents an updated practical approach to the evaluation and management of patients with HF and SMR based upon a Heart Team approach.

15.
Eur Radiol ; 31(7): 5106-5115, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33449184

RESUMEN

OBJECTIVE: Speckle-tracking echocardiography (STE) deformation parameters detect latent LV dysfunction in chronic aortic regurgitation (AR) and are associated with outcomes. The aim of the study was to evaluate cardiac magnetic resonance (CMR) feature tracking (FT) deformation parameters in asymptomatic patients with AR and implications in outcomes. METHODS: Fifty-five patients with AR and 54 controls were included. Conventional functional CMR parameters, aortic regurgitant volume, and fraction were assessed. CMR-FT analysis was performed with a dedicated software. Clinical data was obtained from hospital records. A combined endpoint included all-cause mortality, cardiovascular mortality, aortic valve surgery, or cardiovascular hospital admission due to heart failure. RESULTS: Left ventricular (LV) mechanics is impaired in patients with significant AR. Significant differences were noted in global longitudinal strain (GLS) between controls and AR patients (- 19.1 ± 2.9% vs - 16.5 ± 3.2%, p < 0.001) and among AR severity groups (- 18.3 ± 3.1% vs - 16.2 ± 1.6% vs - 15 ± 3.5%; p = 0.02 for AR grades I-II, III, and IV). In univariate and multivariate analyses, circumferential strain (GCS) and global radial strain (GRS) but not GLS were associated with and increased risk of the end point with a HR of 1.26 (p = 0.016, 1.04-1.52) per 1% worsening for GCS and 0.90 (p = 0.012, 0.83-0.98) per 1% worsening for GRS. CONCLUSIONS: CMR-FT myocardial deformation parameters are impaired in patients with AR not meeting surgical criteria. GLS decreases early in the course of the disease and is a marker of AR severity while GCS and GRS worsen later but predict a bad prognosis, mainly the need of aortic valve surgery. KEY POINTS: • CMR feature tracking LV mechanic parameters may be reduced in significant chronic AR with normal EF. • LV mechanics, mainly global longitudinal strain, worsens as AR severity increases. • LV mechanics, specially global radial and circumferential strain, is associated with a worse prognosis in AR patients.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Disfunción Ventricular Izquierda , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Ecocardiografía , Humanos , Imagen por Resonancia Cinemagnética , Espectroscopía de Resonancia Magnética , Valor Predictivo de las Pruebas , Pronóstico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda
16.
J Am Acad Dermatol ; 84(6): 1644-1651, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33639244

RESUMEN

BACKGROUND: The major concern regarding the use of low-dose oral minoxidil (LDOM) for the treatment of hair loss is the potential risk of systemic adverse effects. OBJECTIVE: To describe the safety of LDOM for the treatment of hair loss in a large cohort of patients. METHODS: Retrospective multicenter study of patients treated with LDOM for at least 3 months for any type of alopecia. RESULTS: A total of 1404 patients (943 women [67.2%] and 461 men [32.8%]) with a mean age of 43 years (range 8-86) were included. The dose of LDOM was titrated in 1065 patients, allowing the analysis of 2469 different cases. The most frequent adverse effect was hypertrichosis (15.1%), which led to treatment withdrawal in 14 patients (0.5%). Systemic adverse effects included lightheadedness (1.7%), fluid retention (1.3%), tachycardia (0.9%), headache (0.4%), periorbital edema (0.3%), and insomnia (0.2%), leading to drug discontinuation in 29 patients (1.2%). No life-threatening adverse effects were observed. LIMITATIONS: Retrospective design and lack of a control group. CONCLUSION: LDOM has a good safety profile as a treatment for hair loss. Systemic adverse effects were infrequent and only 1.7% of patients discontinued treatment owing to adverse effects.


Asunto(s)
Alopecia/tratamiento farmacológico , Minoxidil/efectos adversos , Administración Oral , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Mareo/inducido químicamente , Mareo/epidemiología , Edema/inducido químicamente , Edema/epidemiología , Femenino , Cefalea/inducido químicamente , Cefalea/epidemiología , Humanos , Hipertricosis/inducido químicamente , Hipertricosis/epidemiología , Masculino , Persona de Mediana Edad , Minoxidil/administración & dosificación , Estudios Retrospectivos , Trastornos del Inicio y del Mantenimiento del Sueño/inducido químicamente , Trastornos del Inicio y del Mantenimiento del Sueño/epidemiología , Taquicardia/inducido químicamente , Taquicardia/epidemiología , Adulto Joven
17.
Eur Heart J ; 41(3): 347-356, 2020 01 14.
Artículo en Inglés | MEDLINE | ID: mdl-31504434

RESUMEN

AIMS: Over the last decades, the profile of chronic coronary syndrome has changed substantially. We aimed to determine characteristics and management of patients with chronic coronary syndrome in the contemporary era, as well as outcomes and their determinants. METHODS AND RESULTS: Data from 32 703 patients (45 countries) with chronic coronary syndrome enrolled in the prospective observational CLARIFY registry (November 2009 to June 2010) with a 5-year follow-up, were analysed. The primary outcome [cardiovascular death or non-fatal myocardial infarction (MI)] 5-year rate was 8.0% [95% confidence interval (CI) 7.7-8.3] overall [male 8.1% (7.8-8.5); female 7.6% (7.0-8.3)]. A cox proportional hazards model showed that the main independent predictors of the primary outcome were prior hospitalization for heart failure, current smoking, atrial fibrillation, living in Central/South America, prior MI, prior stroke, diabetes, current angina, and peripheral artery disease. There was an interaction between angina and prior MI (P = 0.0016); among patients with prior MI, angina was associated with a higher primary event rate [11.8% (95% CI 10.9-12.9) vs. 8.2% (95% CI 7.8-8.7) in patients with no angina, P < 0.001], whereas among patients without prior MI, event rates were similar for patients with [6.3% (95% CI 5.4-7.3)] or without angina [6.4% (95% CI 5.9-7.0)], P > 0.99. Prescription rates of evidence-based secondary prevention therapies were high. CONCLUSION: This description of the spectrum of chronic coronary syndrome patients shows that, despite high rates of prescription of evidence-based therapies, patients with both angina and prior MI are an easily identifiable high-risk group who may deserve intensive treatment. CLINICAL REGISTRY: ISRCTN43070564.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Manejo de la Enfermedad , Sistema de Registros , Anciano , Enfermedad Crónica , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/epidemiología , Femenino , Estudios de Seguimiento , Salud Global , Humanos , Masculino , Persona de Mediana Edad , Morbilidad/tendencias , Pronóstico , Estudios Prospectivos , Tasa de Supervivencia/tendencias , Síndrome , Factores de Tiempo
18.
Int J Mol Sci ; 22(6)2021 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-33809359

RESUMEN

In response to cardiac ischemia/reperfusion, proteolysis mediated by extracellular matrix metalloproteinase inducer (EMMPRIN) and its secreted ligand cyclophilin-A (CyPA) significantly contributes to cardiac injury and necrosis. Here, we aimed to investigate if, in addition to the effect on the funny current (I(f)), Ivabradine may also play a role against cardiac necrosis by reducing EMMPRIN/CyPA-mediated cardiac inflammation. In a porcine model of cardiac ischemia/reperfusion (IR), we found that administration of 0.3 mg/kg Ivabradine significantly improved cardiac function and reduced cardiac necrosis by day 7 after IR, detecting a significant increase in cardiac CyPA in the necrotic compared to the risk areas, which was inversely correlated with the levels of circulating CyPA detected in plasma samples from the same subjects. In testing whether Ivabradine may regulate the levels of CyPA, no changes in tissue CyPA were found in healthy pigs treated with 0.3 mg/kg Ivabradine, but interestingly, when analyzing the complex EMMPRIN/CyPA, rather high glycosylated EMMPRIN, which is required for EMMPRIN-mediated matrix metalloproteinase (MMP) activation and increased CyPA bonding to low-glycosylated forms of EMMPRIN were detected by day 7 after IR in pigs treated with Ivabradine. To study the mechanism by which Ivabradine may prevent secretion of CyPA, we first found that Ivabradine was time-dependent in inhibiting co-localization of CyPA with the granule exocytosis marker vesicle-associated membrane protein 1 (VAMP1). However, Ivabradine had no effect on mRNA expression nor in the proteasome and lysosome degradation of CyPA. In conclusion, our results point toward CyPA, its ligand EMMPRIN, and the complex CyPA/EMMPRIN as important targets of Ivabradine in cardiac protection against IR.


Asunto(s)
Basigina/genética , Ciclofilina A/genética , Infarto del Miocardio/tratamiento farmacológico , Proteína 1 de Membrana Asociada a Vesículas/genética , Animales , Biomarcadores/metabolismo , Cardiotónicos/farmacología , Modelos Animales de Enfermedad , Regulación de la Expresión Génica , Corazón/efectos de los fármacos , Corazón/fisiopatología , Humanos , Ivabradina/farmacología , Infarto del Miocardio/genética , Infarto del Miocardio/patología , Porcinos
19.
Echocardiography ; 37(4): 586-591, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32212399

RESUMEN

INTRODUCTION: Limited data are available regarding the evaluation of right ventricular (RV) performance in patients with aortic stenosis (AS) undergoing transcatheter aortic valve implantation (TAVI). OBJECTIVE: To evaluate the prevalence of RV dysfunction in patients with severe AS undergoing TAVI and long-term changes. METHODS: Consecutive patients with severe AS undergoing TAVI from January 2016 to July 2017 were included. RV anatomical and functional parameters were analyzed: RV diameters, fractional area change, tricuspid annular plane systolic excursion (TAPSE), S-wave tissue Doppler of the tricuspid annulus (RV-S'TDI), global longitudinal strain (RV-GLS), and free wall strain (RV-FWS). Preprocedure and 1-year echo were analyzed. RESULTS: Final population included 114 patients, mean age 83.63 ± 6.31 years, and 38.2% women. The prevalence of abnormal RV function was high, variable depending on the parameter that we analyzed, and it showed a significant reduction 1 year after TAVI implantation: 13.9% vs 6.8% (TAPSE < 17mm), P = .04; 26.3% vs 20% (fractional area change < 35%), P = .048; 41.2% vs 29.2% (RV-S'TDI < 9.5cm/s), P = .04; 48.7% vs 39.5% (RV-GLS > [20]), P = .049; and 48.7% vs 28.9% (RV-FWS > [20]), P = .03. Significant differences were noted between patients with low-flow (LF) vs normal-flow (NF) AS in RV dysfunction prevalence as well as in RV function recovery which is less evident in LF compared with NF patients. CONCLUSIONS: RV dysfunction is high among symptomatic AS patients undergoing TAVI, with variable prevalence depending on the echocardiographic parameter used.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Disfunción Ventricular Derecha , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Disfunción Ventricular Derecha/cirugía , Función Ventricular Derecha
20.
Eur Heart J ; 40(22): 1756-1763, 2019 06 07.
Artículo en Inglés | MEDLINE | ID: mdl-30085070

RESUMEN

AIMS: Anticancer therapies have extended the lives of millions of patients with malignancies, but for some this benefit is tempered by adverse cardiovascular (CV) effects. Cardiotoxicity may occur early or late after treatment initiation or termination. The extent of this cardiotoxicity is variable, depending on the type of drug used, combination with other drugs, mediastinal radiotherapy, the presence of CV risk factors, and comorbidities. A recent position paper from the European Society of Cardiology addressed the management of CV monitoring and management of patients treated for cancer. METHODS AND RESULTS: The current document is focused on the basis of the Cardio-Oncology (C-O) Services, presenting their rationale, organization, and implementation. C-O Services address the spectrum of prevention, detection, monitoring, and treatment of cancer patients at risk of cardiotoxicity and/or with concomitant CV diseases. These services require a multidisciplinary approach, with the aims of promoting CV health and facilitating the most effective cancer therapy. CONCLUSION: The expected growing volume of patients with cancer at risk of developing/worsening CV disease, the advent of new technological opportunities to refine diagnosis, and the necessity of early recognition of cancer therapy-related toxicity mandate an integrative multidisciplinary approach and care in a specialized environment. This document from the ESC Cardio-Oncology council proposes the grounds for creating C-O Services in Europe based on expert opinion.


Asunto(s)
Cardiología/organización & administración , Enfermedades Cardiovasculares , Oncología Médica/organización & administración , Modelos Organizacionales , Neoplasias , Cardiología/educación , Enfermedades Cardiovasculares/diagnóstico , Enfermedades Cardiovasculares/prevención & control , Enfermedades Cardiovasculares/terapia , Humanos , Oncología Médica/educación , Neoplasias/diagnóstico , Neoplasias/prevención & control , Neoplasias/terapia , Grupo de Atención al Paciente
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA