Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Pacing Clin Electrophysiol ; 36(1): 24-30, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23078045

RESUMEN

BACKGROUND: The Achieve catheter (AC; Medtronic-CryoCath, Pointe-Claire, Canada) is a circular mapping catheter introduced through the lumen of the cryoballoon (CB) catheter which is safe and effective to both navigate the CB to the pulmonary veins (PV) and allow PV potential recording during PV cryoablation. The aim of this study was to evaluate the impact of the use of the AC on procedural outcomes. METHODS: Sixteen consecutive patients (14 men) underwent AC-guided PV isolation (PVI) for drug-refractory paroxysmal atrial fibrillation (AF; AC group). Clinical and procedural data of these patients were compared to those obtained from 16 consecutive patients who had undergone PVI for paroxysmal AF with the regular "single transseptal" approach (control group). RESULTS: Clinical characteristics of patients enrolled in both groups did not differ significantly. In the AC group, 64 PVs were targeted using a single 28-mm (n = 13) or 23-mm (n = 3) CB catheter with PVI achieved in 62 PVs (97%). In the control group, 66 PVs were targeted using a single 28-mm (n = 12) or 23-mm (n = 4) CB catheter with PVI achieved in 62 PVs (94%), (P = non-significant for CB size and PVI rate). Procedure duration and fluoroscopy time were significantly reduced in AC group compared to control group (96.6 ± 26 minutes vs 125.9 ± 25 minutes, P = 0.003 and 24.4 ± 10 minutes vs 32.6 ± 11 minutes, P = 0.04, respectively). CONCLUSION: The use of the AC significantly reduced procedure duration and radiation exposure during PVI with the CB technique.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Mapeo del Potencial de Superficie Corporal/instrumentación , Criocirugía/instrumentación , Dosis de Radiación , Cirugía Asistida por Computador/instrumentación , Tomografía Computarizada por Rayos X , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Protección Radiológica/métodos , Cirugía Asistida por Computador/métodos , Resultado del Tratamiento
2.
Int J Cardiol ; 168(1): 108-11, 2013 Sep 20.
Artículo en Inglés | MEDLINE | ID: mdl-23044433

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) using cryoballoon (CB) catheter is a new technique for atrial fibrillation (AF) ablation. Previous studies used computer tomography (CT) or magnetic resonance imaging (MRI) scan to determine the pulmonary vein (PV) diameter and anatomy for choosing the CB size. We evaluated pre-ablation transoesophageal-echocardiography (TEE) as an alternative to CT/MRI scan in patients undergoing AF ablation for determining the appropriate size of the CB. METHODS: Fifty-five consecutive patients (men=43, women=12) with a mean age of 63 ± 12.5 years, and with drug-refractory paroxysmal AF (34 patients) or persistent AF (21 patients) were included in this prospective study. All patients underwent pre-ablation TEE. RESULTS: Hypertension was present in 19 patients (34%). Mean anterior-posterior left atrium diameter was 45.1 ± 8.9 mm. In total, 217 PV were targeted using a single 23-mm (n=14) or 28-mm (n=40) CB catheter chosen according to TEE-obtained measurements. PVI was achieved in 195 PV (90%). Mean number of CB applications per patient was 9.8 ± 2.1 (range 8-14). Mean procedure duration and fluoroscopy times were 131 ± 27 min (90-190 min) and 36 ± 12 min (22-66 min) respectively. Phrenic nerve palsy occurred in 3 patients (5.4%) and was transient (<1 month) in all of them. CONCLUSION: This study suggests that TEE is an easily available and effective tool to select the size of the CB for PVI according to evaluated PV diameters and anatomy.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Criocirugía/métodos , Ecocardiografía Transesofágica/métodos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Adulto , Anciano , Anciano de 80 o más Años , Ablación por Catéter/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA