Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Chemistry ; 30(21): e202304152, 2024 Apr 11.
Artículo en Inglés | MEDLINE | ID: mdl-38311589

RESUMEN

Due to the ultrahigh theoretical specific capacity (3860 mAh g-1) and low redox potential (-3.04 V vs. standard hydrogen electrode), Lithium (Li) metal anode (LMA) received increasing attentions. However, notorious dendrite and volume expansion during the cycling process seriously hinder the development of high energy density Li metal batteries. Constructing three-dimensional (3D) current collectors for Li can fundamentally solve the intrinsic drawback of hostless for Li. Therefore, this review systematically introduces the design and synthesis engineering and the current development status of different 3D collectors in recent years (the current collectors are divided into two major parts: metal-based current collectors and carbon-based current collectors). In the end, some perspectives of the future promotion for LMA application are also presented.

2.
Zhonghua Xin Xue Guan Bing Za Zhi ; 38(11): 1025-30, 2010 Nov.
Artículo en Zh | MEDLINE | ID: mdl-21215233

RESUMEN

OBJECTIVE: To explore the effects and related mechanism of nifedipine on vascular inflammation induced by cuff placement. METHODS: Adult male C57BL/6J mice (10 to 12 weeks of age) were assigned to control (no cuff placement without nifedipine), cuff placement (cuff placement without nifedipine) and treatment (cuff placement with nifedipine 1 or 5 mg×kg(-1)×d(-1)) groups. Activity of NF-κB in injured artery was measured 5 days after operation. MCP-1 expression and nuclear translocation of NF-κB were examined in injured artery 7 days after operation. RESULTS: DNA-binding activity of NF-κB was significantly increased in the injured artery 5 days after cuff placement which could be downregulated by nifedipine 5 mg×kg(-1)×d(-1). MCP-1 mRNA expression in the injured arteries was increased 7 days after cuff placement and which could be significantly attenuated by nifedipine 5 mg×kg(-1)×d(-1). Cuff placement decreased the cytoplasmic level of p50, IκBα, IκBß, and increased the nuclear level of p50. Nifedipine 5 mg×kg(-1)×d(-1) significantly attenuated these changes. CONCLUSION: Our results suggest that high dose nifedipine could suppresses expression of MCP-1 induced by injured arteries via the inhibin NF-κB DNA binding activity, thereby attenuating vascular inflammation.


Asunto(s)
FN-kappa B/metabolismo , Nifedipino/farmacología , Enfermedades Vasculares/metabolismo , Animales , Vasos Sanguíneos/metabolismo , Quimiocina CCL2/metabolismo , Inflamación , Masculino , Ratones , Ratones Endogámicos C57BL
3.
Molecules ; 14(2): 608-20, 2009 Feb 04.
Artículo en Inglés | MEDLINE | ID: mdl-19214151

RESUMEN

3-Phenylamino-4-phenyl-1,2,4-triazole-5-thione was synthesized and characterized by elemental analysis, IR and X-ray single crystal diffraction. Density functional theory calculations of the structure, natural bond orbitals, atomic charge distributions and thermodynamic functions of the title compound were performed at B3LYP/ 6-311G** and PBE1PBE/6-311G**levels of theory, respectively. NPA atomic charge distributions indicate that the title compound can be used as a potential multi-dentate ligand to coordinate with various metallic ions. Calculation of the second order optical nonlinearity was also carried out. The thermodynamic properties of C(0)(p,m), S(0)(m) and H(0)(m) were calculated and correlative equations between the thermodynamic properties and temperatures were also obtained.


Asunto(s)
Tionas , Triazoles , Antiinfecciosos/síntesis química , Antiinfecciosos/química , Antiinfecciosos/farmacología , Cristalografía por Rayos X , Hongos/efectos de los fármacos , Enlace de Hidrógeno , Pruebas de Sensibilidad Microbiana , Modelos Químicos , Estructura Molecular , Termodinámica , Tionas/síntesis química , Tionas/química , Triazoles/síntesis química , Triazoles/química
4.
Med Phys ; 35(12): 5426-33, 2008 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19175102

RESUMEN

A given outcome of radiotherapy treatment can be modeled by analyzing its correlation with a combination of dosimetric, physiological, biological, and clinical factors, through a logistic regression fit of a large patient population. The quality of the fit is measured by the combination of the predictive power of this particular set of factors and the statistical significance of the individual factors in the model. We developed a genetic algorithm (GA), in which a small sample of all the possible combinations of variables are fitted to the patient data. New models are derived from the best models, through crossover and mutation operations, and are in turn fitted. The process is repeated until the sample converges to the combination of factors that best predicts the outcome. The GA was tested on a data set that investigated the incidence of lung injury in NSCLC patients treated with 3DCRT. The GA identified a model with two variables as the best predictor of radiation pneumonitis: the V30 (p=0.048) and the ongoing use of tobacco at the time of referral (p=0.074). This two-variable model was confirmed as the best model by analyzing all possible combinations of factors. In conclusion, genetic algorithms provide a reliable and fast way to select significant factors in logistic regression analysis of large clinical studies.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Neoplasias Pulmonares/radioterapia , Neoplasias/radioterapia , Radioterapia/métodos , Análisis de Regresión , Algoritmos , Área Bajo la Curva , Humanos , Modelos Genéticos , Modelos Estadísticos , Modelos Teóricos , Curva ROC , Radiometría , Planificación de la Radioterapia Asistida por Computador , Resultado del Tratamiento
5.
Med Phys ; 35(7): 3110-5, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-18697536

RESUMEN

We developed a novel digital tomosynthesis (DTS) reconstruction method using a deformation field map to optimally estimate volumetric information in DTS images. The deformation field map is solved by using prior information, a deformation model, and new projection data. Patients' previous cone-beam CT (CBCT) or planning CT data are used as the prior information, and the new patient volume to be reconstructed is considered as a deformation of the prior patient volume. The deformation field is solved by minimizing bending energy and maintaining new projection data fidelity using a nonlinear conjugate gradient method. The new patient DTS volume is then obtained by deforming the prior patient CBCT or CT volume according to the solution to the deformation field. This method is novel because it is the first method to combine deformable registration with limited angle image reconstruction. The method was tested in 2D cases using simulated projections of a Shepp-Logan phantom, liver, and head-and-neck patient data. The accuracy of the reconstruction was evaluated by comparing both organ volume and pixel value differences between DTS and CBCT images. In the Shepp-Logan phantom study, the reconstructed pixel signal-to-noise ratio (PSNR) for the 60 degrees DTS image reached 34.3 dB. In the liver patient study, the relative error of the liver volume reconstructed using 60 degrees projections was 3.4%. The reconstructed PSNR for the 60 degrees DTS image reached 23.5 dB. In the head-and-neck patient study, the new method using 60 degrees projections was able to reconstruct the 8.1 degrees rotation of the bony structure with 0.0 degrees error. The reconstructed PSNR for the 60 degrees DTS image reached 24.2 dB. In summary, the new reconstruction method can optimally estimate the volumetric information in DTS images using 60 degrees projections. Preliminary validation of the algorithm showed that it is both technically and clinically feasible for image guidance in radiation therapy.


Asunto(s)
Gráficos por Computador , Computadores , Tomografía Computarizada por Rayos X/métodos , Algoritmos , Tomografía Computarizada de Haz Cónico/métodos , Humanos , Procesamiento de Imagen Asistido por Computador , Neoplasias/diagnóstico , Neoplasias/patología , Fantasmas de Imagen , Radioterapia/métodos , Planificación de la Radioterapia Asistida por Computador , Reproducibilidad de los Resultados , Técnica de Sustracción , Interfaz Usuario-Computador
6.
Semin Radiat Oncol ; 17(2): 72-80, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17395037

RESUMEN

Normal tissue injury after radiation therapy (RT) can be defined based on either clinical symptoms or laboratory/radiologic tests. In the research setting, functional imaging (eg, single-photon emission computed tomography [SPECT], positron-emission tomography [PET], and magnetic resonance imaging [MRI]) is useful because it provides objective quantitative data such as metabolic activity, perfusion, and soft-tissue contrast within tissues and organs. For RT-induced lung, heart, and parotid gland injury, pre- and post-RT SPECT images can be compared with the dose- and volume-dependent nature of regional injury. In the brain, SPECT can detect changes in perfusion and blood flow post-RT, and PET can detect metabolic changes, particularly to regions of the brain that have received doses above 40 to 50 Gy. On MRI, changes in contrast-enhanced images, T(1) and T(2) relaxation times, and pulmonary vascular resistance at different intervals pre- and post-RT show its ability to detect and distinguish different phases of radiation pneumonitis. Similarly, conventional and diffusion-weighted MRI can be used to differentiate between normal tissue edema, necrosis, and tumor in the irradiated brain, and magnetic resonance spectroscopy can measure changes in compounds, indicative of membrane and neuron disruption. The use of functional imaging is a powerful tool for early detection of RT-induced normal tissue injury, which may be related to long-term clinically significant injury.


Asunto(s)
Imagen por Resonancia Magnética , Traumatismos por Radiación/diagnóstico , Radioterapia/efectos adversos , Tomografía Computarizada de Emisión de Fotón Único , Relación Dosis-Respuesta en la Radiación , Humanos , Traumatismos por Radiación/diagnóstico por imagen , Dosificación Radioterapéutica
7.
Med Phys ; 34(7): 2807-15, 2007 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17821988

RESUMEN

Traditional methods to compute the tumor control probability (TCP) or normal tissue complication probability (NTCP) typically require a heterogeneous radiation dose distribution to be converted into a simple uniform dose distribution with an equivalent biological effect. Several power-law type dose-volume-histogram reduction schemes, particularly Niemierko's generalized equivalent uniform dose model [Med. Phys. 26, 1000 (1999)], have been proposed to achieve this goal. In this study, we carefully examine the mathematical outcome of these schemes. We demonstrate that (1) for tumors, with each tumor cell independently responding to local radiation dose, a closed-form analytical solution for tumor survival fraction and TCP can be obtained; (2) for serial structured normal tissues, an exponential power-law form relating survival to functional sub-unit (FSU) radiation is required, and a closed-form analytical solution for the related NTCP is provided; (3) in the case of a parallel structured normal tissue, when NTCP is determined solely by the number of the surviving FSUs, a mathematical solution is available only when there is a non-zero threshold dose and/or a finite critical dose defining the radiotherapy response. Some discussion is offered for the partial irradiation effect on normal tissues in this category; (4) for normal tissues with alternative architectures, where the radiation response of FSU is inhomogeneous, there is no exact global mathematical solution for SF or NTCP within the available schemes. Finally, numerical fits of our models to some experimental data are also presented.


Asunto(s)
Relación Dosis-Respuesta en la Radiación , Probabilidad , Humanos , Modelos Biológicos , Modelos Teóricos , Neoplasias/radioterapia
8.
Med Phys ; 44(5): 1939-1947, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-28273341

RESUMEN

PURPOSE: Inhomogeneity dose modeling and respiratory motion description are two critical technical challenges for lung stereotactic body radiotherapy, an important treatment modality for small size primary and secondary lung tumors. Recent studies revealed lung density-dependent target dose differences between Monte Carlo (Type-C) algorithm and earlier algorithms. Therefore, this study aimed to investigate the equivalence of the two most popular CT datasets for treatment planning, free breathing (FB) and average intensity projection (AIP) CTs, using Type-C algorithms, and comparing with two older generation algorithms (Type-A and Type-B). METHODS: Twenty patients (twenty-one lesions) were planned using a Type-A algorithm on the FB CT. Lung was contoured separately on FB and AIP CTs and compared. Dose comparison was obtained between the two CTs using four commercial dose algorithms including one Type-A (Pencil Beam Convolution - PBC), one Type-B (Analytical Anisotropic Algorithm - AAA), and two Type-C algorithms (Voxel Monte Carlo - VMC and Acuros External Beam - AXB). For each algorithm, the dosimetric parameters of the target (PTV, Dmin , Dmax , Dmean , D95, and D90) and lung (V5, V10, V20, V30, V35, and V40) were compared between the two CTs using the Wilcoxon signed rank test. Correlation between dosimetric differences and density differences for each algorithm were studied using linear regression and Spearman correlation, in which both global and local density differences were evaluated. RESULTS: Although the lung density differences on FB and AIP CTs were statistically significant (P = 0.003), the magnitude was small at 1.21 ± 1.45%. Correspondingly, for the two Type-C algorithms, target and lung dosimetric differences were small in magnitude and statistically insignificant (P > 0.05) for all but one instance, similar to the findings for the older generation algorithms. Nevertheless, a significant correlation was shown between the dosimetric and density differences for Type-C and Type-B algorithms, but not for the Type-A algorithm. CONCLUSIONS: With the capability to more accurately model inhomogeneity, Monte Carlo (Type-C) algorithms are sensitive to respiration-induced local and global tissue density changes and exhibit a strong correlation between dosimetric and density differences. However, FB and AIP CTs may still be considered equivalent for dose calculation in the Monte Carlo era, due to the small magnitude of lung density differences between these two datasets.


Asunto(s)
Algoritmos , Neoplasias Pulmonares/radioterapia , Método de Montecarlo , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Humanos , Radiocirugia , Tomografía Computarizada por Rayos X
9.
Semin Radiat Oncol ; 16(2): 85-101, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16564444

RESUMEN

Oligometastases refer to metastases that are limited in number and location and are amenable to regional treatment. The majority of these metastases appear in the brain, lung, liver, and bone. Although the focus of interest in the past within radiation oncology has been on the treatment of intracranial metastases, there has been growing interest in extracranial sites such as the liver and lung. This is largely because of the rapid development of targeting techniques for oligometastases such as intensity-modulated and image-guided radiation therapy, which has made it possible to deliver single or a few fractions of high-dose radiation treatments, highly conformal to the target. The clinical decision to use radiation to treat oligometastases is based on both radiobiological and physics considerations. The radiobiological considerations involve improvement of treatment schema for time, dose, and volume. Areas of interests are hypofractionation, tumor and normal tissue tolerance, and hypoxia. The physics considerations for oligometastases treatment are focused mainly on ensuring treatment accuracy and precision. This article discusses the physics and imaging aspects involved in each step of the radiation treatment process for oligometastases, including target definition, treatment simulation, treatment planning, pretreatment target localization, radiation delivery, treatment verification, and treatment evaluation.


Asunto(s)
Imagenología Tridimensional , Metástasis de la Neoplasia/radioterapia , Técnicas Estereotáxicas , Irradiación Corporal Total/métodos , Fraccionamiento de la Dosis de Radiación , Relación Dosis-Respuesta en la Radiación , Humanos , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Radiometría , Radiocirugia/instrumentación , Radiocirugia/métodos , Planificación de la Radioterapia Asistida por Computador , Restricción Física
10.
Lung Cancer ; 52(1): 111-6, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16483686

RESUMEN

PURPOSE: Symptomatic narrowing of the tracheobronchial tree is not a common clinical problem after conventional-dose external beam radiation therapy but has been described when higher doses are utilized. This in-depth study quantifies changes in the caliber of the trachea and mainstem bronchi after high-dose external beam radiation therapy (EBRT). METHODS AND MATERIALS: As part of an IRB-approved prospective clinical trial to assess for radiation-induced lung injury, patients with thoracic malignancies had pre- and serial post-RT CT scans in the radiation oncology department. This report focuses on 18 enrolled patients who received high-dose (> or = 73.6 Gy) EBRT for NSCLC. The caliber of the trachea, right mainstem bronchus, and left mainstem bronchus were measured utilizing three-dimensional coordinates in axial and coronal planes such that multiple measurements were made of each structure. The decrease in airway caliber was tested for significance using a one-sided Wilcoxon matched-pairs signed-ranks test. The correlation between airway caliber changes, dose, and follow-up interval was tested using the Spearman rank correlation coefficient and the effect of chemotherapy on airway narrowing was evaluated with a one-sided exact Wilcoxon rank sum test. RESULTS: There was no significant narrowing of the trachea for all dose and time points. There were significant decreases in the caliber of both mainstem bronchi on axial measurements (p = 0.07 and 0.005 for right and left mainstem bronchi, respectively). Decrease in airway caliber ranged from 6 to 57% and appeared to be dose dependent (p = 0.08), progressed with increasing time post-RT (p = 0.04), and was worse in patients who also received chemotherapy (p = 0.04). CONCLUSION: High-dose EBRT (> or = 73.6 Gy) appears to cause narrowing of the mainstem bronchi as early as 3 months post radiation therapy. Additional study is needed to assess the impact of such narrowing on RT-induced pulmonary symptoms.


Asunto(s)
Bronquios/efectos de la radiación , Constricción Patológica/etiología , Lesión Pulmonar , Neoplasias Pulmonares/radioterapia , Traumatismos por Radiación/complicaciones , Tráquea/efectos de la radiación , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosificación Radioterapéutica
11.
Phys Med ; 32(2): 379-85, 2016 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-26896390

RESUMEN

PURPOSE: In the present study, clinical stereotactic radiosurgery (SRS) setup uncertainties from image-guidance data are analyzed, and the corresponding setup margin is estimated for treatment planning purposes. METHODS: Patients undergoing single-fraction SRS at our institution were localized using invasive head ring or non-invasive thermoplastic masks. Setup discrepancies were obtained from an in-room x-ray patient position monitoring system. Post treatment re-planning using the measured setup errors was performed in order to estimate the individual target margins sufficient to compensate for the actual setup errors. The formula of setup margin for a general SRS patient population was derived by proposing a correlation between the three-dimensional setup error and the required minimal margin. RESULTS: Setup errors of 104 brain lesions were analyzed, in which 81 lesions were treated using an invasive head ring, and 23 were treated using non-invasive masks. In the mask cases with image guidance, the translational setup uncertainties achieved the same level as those in the head ring cases. Re-planning results showed that the margins for individual patients could be smaller than the clinical three-dimensional setup errors. The derivation of setup margin adequate to address the patient setup errors was demonstrated by using the arbitrary planning goal of treating 95% of the lesions with sufficient doses. CONCLUSIONS: With image guidance, the patient setup accuracy of mask cases can be comparable to that of invasive head rings. The SRS setup margin can be derived for a patient population with the proposed margin formula to compensate for the institution-specific setup errors.


Asunto(s)
Aceleradores de Partículas , Radiocirugia/instrumentación , Planificación de la Radioterapia Asistida por Computador/métodos , Errores de Configuración en Radioterapia , Incertidumbre , Humanos , Radioterapia Guiada por Imagen
12.
Int J Radiat Oncol Biol Phys ; 62(3): 635-8, 2005 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-15936538

RESUMEN

PURPOSE: To assess the difficulty of assigning a definitive clinical diagnosis of radiation (RT)-induced lung injury in patients irradiated for lung cancer. METHODS: Between 1991 and 2003, 318 patients were enrolled in a prospective study to evaluate RT-induced lung injury. Only patients with lung cancer who had a longer than 6-month follow-up (251 patients) were considered in the current analysis. Of these, 47 of 251 patients had Grade >/=2 (treated with steroids) increasing shortness of breath after RT, thought possibly consistent with pneumonitis/fibrosis. The treating physician, and one to three additional reviewing physicians, evaluated the patients or their medical records, or both. The presence or absence of confounding clinical factors that made the diagnosis of RT-induced uncertain lung injury were recorded. RESULTS: Thirty-one of 47 patients (66%) with shortness of breath had "classic" pneumonitis, i.e., they responded to steroids and had a definitive diagnosis of pneumonitis. In 13 of 47 patients (28%), the diagnosis of RT-induced toxicity was confounded by possible infection; exacerbation of preexisting lung disease (chronic obstructive pulmonary disease); tumor regrowth/progression; and cardiac disease in 6, 8, 5, and 1 patients, respectively (some of the patients had multiple confounding factors and were counted more than once). An additional 3 patients (6%) had progressive shortness of breath and an overall clinical course more consistent with fibrosis. All 3 had evidence of bronchial stenosis by bronchoscopy. CONCLUSIONS: Scoring of radiation pneumonitis was challenging in 28% of patients treated for lung cancer owing to confounding medical conditions. Recognition of this uncertainty is needed and may limit our ability to understand RT-induced lung injury.


Asunto(s)
Neoplasias Pulmonares/radioterapia , Neumonitis por Radiación/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Disnea/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Enfermedad Pulmonar Obstructiva Crónica/complicaciones , Neumonitis por Radiación/complicaciones
13.
Int J Radiat Oncol Biol Phys ; 63(1): 214-23, 2005 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-16111592

RESUMEN

PURPOSE: Radiation therapy (RT) for left-sided breast cancer has been associated with cardiac dysfunction. We herein assess the temporal nature and volume dependence of RT-induced left ventricular perfusion defects and whether these perfusion defects are related to changes in cardiac wall motion or alterations in ejection fraction. METHODS: From 1998 to 2001, 114 patients were enrolled onto an IRB-approved prospective clinical study to assess changes in regional and global cardiac function after RT for left-sided breast cancer. Patients were imaged 30 to 60 minutes after injection of technetium 99m sestamibi or tetrofosmin. Post-RT perfusion scans were compared with the pre-RT studies to assess for RT-induced perfusion defects as well as functional changes in wall motion and ejection fraction. Two-tailed Fisher's exact test and the Cochran-Armitage test for linear trends were used for statistical analysis. RESULTS: The incidence of new perfusion defects 6, 12, 18, and 24 months after RT was 27%, 29%, 38%, and 42%, respectively. New defects occurred in approximately 10% to 20% and 50% to 60% of patients with less than 5%, and greater than 5%, of their left ventricle included within the RT fields, respectively (p = 0.33 to 0.00008). The rates of wall motion abnormalities in patients with and without perfusion defects were 12% to 40% versus 0% to 9%, respectively; p values were 0.007 to 0.16, depending on the post-RT interval. CONCLUSIONS: Radiation therapy causes volume-dependent perfusion defects in approximately 40% of patients within 2 years of RT. These perfusion defects are associated with corresponding wall-motion abnormalities. Additional study is necessary to better define the long-term functional consequences of RT-induced perfusion defects.


Asunto(s)
Neoplasias de la Mama/radioterapia , Corazón/efectos de la radiación , Contracción Miocárdica/efectos de la radiación , Traumatismos por Radiación/fisiopatología , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Mama/patología , Neoplasias de la Mama/fisiopatología , Circulación Coronaria/fisiología , Circulación Coronaria/efectos de la radiación , Femenino , Corazón/diagnóstico por imagen , Corazón/fisiopatología , Humanos , Persona de Mediana Edad , Contracción Miocárdica/fisiología , Estudios Prospectivos , Dosis de Radiación , Traumatismos por Radiación/diagnóstico por imagen , Volumen Sistólico/fisiología , Volumen Sistólico/efectos de la radiación , Tomografía Computarizada de Emisión de Fotón Único
14.
Int J Radiat Oncol Biol Phys ; 62(4): 1009-13, 2005 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-15990002

RESUMEN

PURPOSE: To assess the 6-minute walk test (6MWT) as a predictor of radiation therapy-induced lung injury (RTLI). METHODS AND MATERIALS: The 6MWT is a simple, economical, and reproducible test that measures both how far a person can walk in 6 min and any associated changes in vital signs. As part of a prospective trial to study RTLI, a pre-RT 6MWT was performed in 41 patients. The predictive capacities of pre-RT 6MWT, forced expiratory volume in 1 s (FEV1), and single-breath diffusing capacity for carbon monoxide (DLCO) for the development of RTLI were assessed with receiver operating curve (ROC) techniques. To evaluate the 6MWT, alone or with mean lung dose (MLD) of radiation, as a predictor of RTLI, the rates of RTLI in patient subgroups defined by 6MWT results were compared by using Fisher's exact test. RESULTS: Thirty-one patients with > or =3 months' follow-up were evaluable. The median baseline 6MWT result was 1400 ft. Of 31 patients, 7 developed Grade > or =2 RTLI. Of 15 patients with an MLD >18 Gy (the median), 5 developed RTLI, compared with 2 of 16 with MLD < or =18 Gy (p = 0.22). Among those with an MLD < or =18 Gy, the RTLI rates were 0 of 8 and 2 of 8 for 6MWT results > or =1400 ft or <1400 ft, respectively, p = 0.46. The ROC area under the curve for individual metrics was as follows: FEV1 0.66, MLD 0.70, DLCO 0.61, and 6MWT 0.47. Combining FEV1 with 6MWT increased the ROC to 0.71, suggesting that the ratio might be a better predictor than the individual values. Patients with a high 6MWT/FEV1 ratio had a lower rate of RTLI than those with a relatively low ratio. CONCLUSIONS: The 6MWT might provide prognostic information beyond pulmonary function tests and dosimetric parameters in predicting RTLI. Additional work is needed to better assess the utility of these functional metrics.


Asunto(s)
Pulmón/efectos de la radiación , Traumatismos por Radiación/fisiopatología , Adulto , Anciano , Prueba de Esfuerzo , Tolerancia al Ejercicio , Femenino , Volumen Espiratorio Forzado , Humanos , Pulmón/fisiopatología , Mediciones del Volumen Pulmonar , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Capacidad de Difusión Pulmonar , Curva ROC , Traumatismos por Radiación/etiología
15.
Int J Radiat Oncol Biol Phys ; 61(1): 64-9, 2005 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-15629595

RESUMEN

PURPOSE: To assess the incidence of clinically significant bronchial stenosis in patients treated with high doses (i.e., >70 Gy) of twice-daily external beam radiation therapy (RT). METHODS AND MATERIALS: The outcomes of 103 patients with unresectable non-small-cell lung cancer, treated twice daily to doses ranging from 7080 to 8640 cGy between 1992 and 2001, were analyzed. Most were treated on prospective clinical trials. For the dose-effect comparison, the patients were divided on the basis of the total dose: 67 received 74 Gy (range, 70.8-74.5 Gy; median, 73.6 Gy), 20 received 80 Gy, and 16 received 86 Gy (range, 85.2-86.4 Gy; median, 86.4 Gy). Sixty-six patients received sequential chemotherapy before RT. RT-induced bronchial stenosis was defined as symptomatic airway narrowing diagnosed by bronchoscopy or computed tomography scan without evidence of recurrent tumor in that region. RESULTS: Eight patients developed RT-induced, clinically significant, bronchial stenosis 2-48 months (median, 6 months) after RT. The 1-year and 4-year actuarial rate of stenosis was 7% and 38%, respectively. The median overall survival was 2.5 years (5 of 8 were alive at the writing of this report). A suggestion was also found of a dose-response effect with external beam radiotherapy-induced stenosis, with a rate of 4% and 25% at a dose of approximately 74 Gy and 86 Gy, respectively. CONCLUSION: Radiation therapy-induced bronchial stenosis is a significant clinical complication of dose escalation for lung cancer. This complication has been previously mentioned in the literature, but ours is the largest report to date, and the findings suggest that the risk rises with increasing dose. It is likely that this process would manifest in more patients if their disease were controlled well enough for more prolonged survival.


Asunto(s)
Bronquios/efectos de la radiación , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Neoplasias Pulmonares/radioterapia , Traumatismos por Radiación/complicaciones , Constricción Patológica/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dosificación Radioterapéutica
16.
Int J Radiat Oncol Biol Phys ; 55(4): 914-20, 2003 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-12605969

RESUMEN

PURPOSE: To evaluate postradiation regional heart perfusion changes with single photon emission tomography (SPECT) myocardial perfusion imaging in 69 patients treated with tangential photon beams radiation therapy (RT) for left-sided breast cancer. To correlate SPECT changes with percent irradiated left ventricle (LV) volume and risk factors for coronary artery disease (CAD). METHODS AND MATERIALS: Rest SPECT of the LV was acquired pre-RT and at 6-month intervals post-RT. The extent of defects (%) with a severity > 1.5 standard deviations below the mean was quantitatively analyzed for the distributions of the left anterior descending (LAD) artery, left circumflex (LCX) artery, and right coronary artery (RCA) based on computer assisted polar map reconstruction (i.e., bull's-eye-view). Changes in perfusion were correlated with percent irradiated LV receiving > 25 Gy (range 0-32%). Data on patient- and treatment-related factors were collected prospectively (e.g., cardiac premorbidity, risk factors for CAD, chemotherapy, and hormonal treatment). RESULTS: In the LAD distribution, there were increased perfusion defects at 6 months (median 11%; interquartile range 2-23) compared with baseline (median 5%; interquartile range 1-14) (p < 0.001). There were no increases in perfusion defects in the LCX or RCA distributions. In multivariate analysis, the SPECT perfusion changes in the LAD distribution at 6 months were independently associated with percent irradiated LV (p < 0.001), hormonal therapy (p = 0.005), and pre-RT hypercholesterolemia (p = 0.006). The SPECT defects in the LAD distribution at 12 and 18 months were not statistically different from those at 6 months. The perfusion defects in the LAD distribution were limited essentially to the regions of irradiated myocardium. CONCLUSION: Tangential photon beam RT in patients with left-sided breast cancer was associated with short-term SPECT defects in the vascular distribution corresponding to the radiation portals. Factors related to the extent of perfusion defects included the percent irradiated LV, hormonal treatment, and pre-RT hypercholesterolemia.


Asunto(s)
Neoplasias de la Mama/radioterapia , Circulación Coronaria/efectos de la radiación , Vasos Coronarios/diagnóstico por imagen , Corazón/diagnóstico por imagen , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Anciano , Neoplasias de la Mama/patología , Circulación Coronaria/fisiología , Enfermedad Coronaria/diagnóstico por imagen , Enfermedad Coronaria/fisiopatología , Vasos Coronarios/anatomía & histología , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/efectos de la radiación , Humanos , Masculino , Mastectomía Segmentaria , Persona de Mediana Edad , Estudios Prospectivos , Dosificación Radioterapéutica , Radioterapia Conformacional , Función Ventricular Izquierda
17.
Int J Radiat Oncol Biol Phys ; 56(3): 611-5, 2003 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-12788165

RESUMEN

PURPOSE: To evaluate the long-term changes in pulmonary function tests (PFTs) in patients surviving at least 2 years after definitive radiotherapy (RT) for unresectable lung cancer. METHODS AND MATERIALS: Between 1992 and 2000, 277 patients were enrolled in a prospective clinical study to relate RT-induced changes in lung function with dosimetric and functional metrics. Of these, 128 received definitive RT for lung cancer, and 13 of these had follow-up PFTs for approximately >/=2 years without evidence of recurrent or progressive cancer. PFTs were obtained before RT and approximately every 6 months after RT. The results were evaluated on the basis of each study's "percentage of predicted" of normal values (i.e., adjusted for age, gender, height), and a patient's sequential examinations were compared with their initial study and a percentage of the baseline value was calculated. Follow-up PFTs were available for a median of 38 months (range 23-95). The median patient age was 65 years (range 40-74), 6 patients were men, and 10 were white. Most had Stage T2-T4 and N2-N3. The median RT dose was 71.4 Gy (range 60-73), 6 had twice-daily RT. Four patients received chemotherapy, one concurrent and three neoadjuvant. None of the patients continued to smoke after their treatment. The median pre-RT PFT results were (percentage of predicted) forced expiratory volume in 1 s, 67% (range 24-121); forced vital capacity, 72% (range 45-116); and diffusing capacity of lung for carbon monoxide, 70% (range 41-129). RESULTS: At 6 months, all PFT values had declined, with some stabilization by 1 year. However, after 1 year, a gradual reduction occurred in all three parameters. Ten patients (77%) developed RT-induced respiratory symptoms (2 cough only, 8 dyspnea) at 2-21 months (median 5) after treatment. Two patients required inhalers, another required long-term steroids and oxygen. Of the 8 patients with dyspnea, 7 had an increase in symptoms beyond 2 years. No patient died of RT-induced pulmonary insufficiency. CONCLUSION: RT caused a decline in PFTs that was apparent at 6 months and continued well beyond 1 year. The continued decline in PFTs is suggestive of progressive/evolving RT-induced lung injury. "Late" pulmonary symptoms have also occurred in these patients. Because of the high mortality rate of unresectable lung cancer, few patients can be evaluated for long-term analysis. Additional studies and pooling of data from multiple institutions may help to clarify better the long-term impact of RT on pulmonary function in this subset of patients.


Asunto(s)
Neoplasias Pulmonares/radioterapia , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Pulmón/fisiopatología , Pulmón/efectos de la radiación , Neoplasias Pulmonares/complicaciones , Neoplasias Pulmonares/fisiopatología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Dosificación Radioterapéutica , Pruebas de Función Respiratoria
18.
Int J Radiat Oncol Biol Phys ; 54(2): 340-7, 2002 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-12243806

RESUMEN

PURPOSE: To assess the utility of dosimetric/functional metrics as predictors of symptomatic radiation pneumonitis using receiver operating characteristic curves. METHODS: Between 1991 and 1999, 277 patients were enrolled on a prospective clinical study to relate radiation therapy (RT) induced changes in lung function with dosimetric and functional metrics. Pre-RT whole and regional functional assessments included pulmonary function tests and single photon emission computed tomography lung perfusion scans. Patients had three-dimensional planning scans and dose calculations (reflecting tissue density heterogeneity) to provide a dose-volume histogram of the lung and associated dosimetric parameters (MLD = mean lung dose, V30 = % of lung receiving >or=30 Gy). Fusion of single photon emission computed tomography and computed tomography scans provides perfusion-weighted dose-function histograms and associated dosimetric parameters (mean perfusion-weighted lung dose). The incidence of clinically relevant radiation pneumonitis requiring steroids was related to the dosimetric and functional metrics. The predictive abilities of models (sensitivity and specificity) were calculated and compared based on the area beneath receiver operating characteristic (ROC) curves (Wilcoxon rank-sum and chi-square). RESULTS: Twenty-seven of 162 evaluable patients with >or=6 months' follow-up developed pneumonitis requiring steroids. Single metrics were typically not good predictors for pneumonitis ( area under ROC curve = 0.5-0.68). The two-dimensional models (e.g., MLD and pre-RT diffusion capacity for carbon monoxide) generally provided greater ROC areas (0.61-0.72). Overall, the models that considered a measure of pre-RT lung function (i.e., pulmonary function tests), the MLD, and mean perfusion-weighted lung dose were best correlated with outcome (ROC area: 0.7) (p < 0.05 compared to unidimensional models). However, because the area under the ROC curve for these models was <<1, they too seemed not to be ideal. CONCLUSION: Predicting symptomatic radiation pneumonitis remains difficult. Multiparameter models that consider pre-RT pulmonary function and the three-dimensional dose distribution seem to be best able to predict outcome. Additional studies are needed to better understand the dosimetric/functional determinants of radiation pneumonitis.


Asunto(s)
Modelos Estadísticos , Curva ROC , Neumonitis por Radiación/etiología , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Neoplasias/tratamiento farmacológico , Neoplasias/radioterapia , Estudios Prospectivos , Dosificación Radioterapéutica , Análisis de Regresión
19.
Int J Radiat Oncol Biol Phys ; 53(4): 835-46, 2002 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-12095548

RESUMEN

PURPOSE: To investigate the importance of CT-defined total tumor volume (TTV) on overall survival (OS) in patients with unresectable or medically inoperable non-small-cell lung carcinoma (NSCLC). METHODS AND MATERIALS: Between 1991 and 1998, 150 evaluable patients with Stage I-IIIB NSCLC were treated with three-dimensionally planned conformal radiotherapy and curative intent at Duke University Medical Center. On the treatment-planning CT, the primary tumor and nodal volumes were identified and subsequently combined to form the TTV. The TTV was compared with the stage and outcome with respect to OS, local progression-free survival, and distant failure-free survival using the Kruskall-Wallis analysis of variance and Kaplan-Meier actuarial method. To account for the potentially confounding effects of therapeutic and patient-specific covariates on survival, the Cox proportional hazard regression model was used. RESULTS: The TTVs in patients with Stage I disease (median 19 cm3) were smaller than in patients with Stage II (median 80 cm3) or Stage III (median 97 cm3; p <0.001) disease. The Stage II TTVs were not significantly different from those of Stage III (post-hoc test according to Bonferroni). Prolonged OS was independently associated with a small TTV (<80 vs. >80 cm3 [median]; p = 0.01), young age (<60 vs. > or =60 years; p = 0.03), high Karnofsky performance status (< o r =70 vs. >70; p = 0.04), and female gender (p = 0.04). Both stage (p = 0.7) and T stage (p = 0.06) were of less importance for OS than was the TTV, according to multivariate modeling. Increased local progression-free survival (p = 0.001) and distant failure-free survival (p = 0.03) were independently associated with a small TTV (i.e., <80 cm3). The results were unchanged if the TTV was analyzed as a continuous variable. CONCLUSION: A strong independent association between a small CT-defined TTV and prolonged survival in patients with NSCLC selected for curative/definitive RT was found. Future therapeutic studies in NSCLC should consider stratifying/adjusting for differences in TTV to avoid confounding effects on survival from variations in the TTV at baseline.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/mortalidad , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Neoplasias Pulmonares/mortalidad , Neoplasias Pulmonares/radioterapia , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/patología , Supervivencia sin Enfermedad , Femenino , Humanos , Neoplasias Pulmonares/patología , Masculino , Persona de Mediana Edad , Factores de Tiempo
20.
Med Phys ; 31(9): 2577-83, 2004 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-15487740

RESUMEN

The concept of equivalent uniform dose (EUD) has been suggested as a means to quantitatively consider heterogeneous dose distributions within targets. Tumor cell density/function is typically assumed to be uniform. We herein propose to use 18F-labeled 2-deoxyglucose (FDG) positron emission tomography (PET) tumor imaging activity as a surrogate marker for tumor cell density to allow the EUD concept to include intratumor heterogeneities and to study its effect on EUD calculation. Thirty-one patients with lung cancer who had computerized tomography (CT)-based 3D planning and PET imaging were studied. Treatment beams were designed based on the information from both the CT and PET scans. Doses were calculated in 3D based on CT images to reflect tissue heterogeneity. The EUD was calculated in two different ways: first, assuming a uniform tumor cell density within the tumor target; second, using FDG-PET activity (counts/cm3) as a surrogate for tumor cell density at different parts of tumor to calculate the functional-imaging-weighted EUD (therefore will be labeled fEUD for convenience). The EUD calculation can be easily incorporated into the treatment planning process. For 28/31 patients, their fEUD and EUD differed by less than 6%. Twenty-one of these twenty-eight patients had tumor volumes < 200 cm3. In the three patients with larger tumor volume, the fEUD and EUD differed by 8%-14%. Incorporating information from PET imaging to represent tumor cell density in the EUD calculation is straightforward. This approach provides the opportunity to include heterogeneity in tumor function/metabolism into the EUD calculation. The difference between fEUD and EUD, i.e., whether including or not including the possible tumor cell density heterogeneity within tumor can be significant with large tumor volumes. Further research is needed to assess the usefulness of the fEUD concept in radiation treatment.


Asunto(s)
Fluorodesoxiglucosa F18 , Interpretación de Imagen Asistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Radiometría/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Algoritmos , Recuento de Células/métodos , Relación Dosis-Respuesta en la Radiación , Humanos , Neoplasias Pulmonares/patología , Estadificación de Neoplasias/métodos , Tomografía de Emisión de Positrones/métodos , Radiofármacos , Dosificación Radioterapéutica , Efectividad Biológica Relativa , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA