Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 249
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Appl Clin Med Phys ; 23(11): e13810, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36316761

RESUMEN

PURPOSE: To quantify the clinical practice of respiratory motion management in radiation oncology. METHODS: A respiratory motion management survey was designed and conducted based on clinician survey guidelines. The survey was administered to American Association of Physicists in Medicine (AAPM) members on 17 August 2020 and closed on 13 September 2020. RESULTS: A total of 527 respondents completed the entire survey and 651 respondents completed part of the survey, with the partially completed surveys included in the analysis. Overall, 84% of survey respondents used deep inspiration breath hold for left-sided breast cancer. Overall, 83% of respondents perceived respiratory motion management for thoracic and abdominal cancer radiotherapy patients to be either very important or required. Overall, 95% of respondents used respiratory motion management for thoracic and abdominal sites, with 36% of respondents using respiratory motion management for at least 90% of thoracic and abdominal patients. The majority (60%) of respondents used the internal target volume method to treat thoracic and abdominal cancer patients, with 25% using breath hold or abdominal compression and 13% using gating or tracking. CONCLUSIONS: A respiratory motion management survey has been completed by AAPM members. Respiratory motion management is generally considered very important or required and is widely used for breast, thoracic, and abdominal cancer treatments.


Asunto(s)
Oncología por Radiación , Humanos , Estados Unidos , Dosificación Radioterapéutica , Tomografía Computarizada por Rayos X/métodos , Contencion de la Respiración , Movimiento (Física) , Planificación de la Radioterapia Asistida por Computador/métodos , Encuestas y Cuestionarios
2.
BMC Cancer ; 20(1): 1165, 2020 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-33256671

RESUMEN

BACKGROUND: The primary aim was to test the hypothesis that deriving pre-treatment 3D magnetic resonance tumour volume (mrTV) quantification improves performance characteristics for the prediction of loco-regional failure compared with standard maximal tumour diameter (1D) assessment in patients with squamous cell carcinoma of the anus undergoing chemoradiotherapy. METHODS: We performed an early evaluation case-control study at two UK centres (2007-2014) in 39 patients with loco-regional failure (cases), and 41 patients disease-free at 3 years (controls). mrTV was determined using the summation of areas method (Volsum). Reproducibility was assessed using intraclass concordance correlation (ICC) and Bland-Altman limits of agreements. We derived receiver operating curves using logistic regression models and expressed accuracy as area under the curve (ROCAUC). RESULTS: The median time per patient for Volsum quantification was 7.00 (inter-quartile range, IQR: 0.57-12.48) minutes. Intra and inter-observer reproducibilities were generally good (ICCs from 0.79 to 0.89) but with wide limits of agreement (intra-observer: - 28 to 31%; inter-observer: - 28 to 46%). Median mrTVs were greater for cases (32.6 IQR: 21.5-53.1 cm3) than controls (9.9 IQR: 5.7-18.1 cm3, p < 0.0001). The ROCAUC for mrT-size predicting loco-regional failure was 0.74 (95% CI: 0.63-0.85) improving to 0.82 (95% CI: 0.72-0.92) when replaced with mrTV (test for ROC differences, p = 0.024). CONCLUSION: Preliminary results suggest that the replacement of mrTV for mrT-size improves prediction of loco-regional failure after chemoradiotherapy for squamous cell carcinoma of the anus. However, mrTV calculation is time consuming and variation in its reproducibility are drawbacks with the current technology.


Asunto(s)
Neoplasias del Ano/diagnóstico por imagen , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Estudios de Casos y Controles , Femenino , Humanos , Masculino
3.
Acta Oncol ; 58(2): 200-208, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30375905

RESUMEN

BACKGROUND: To assess the impact of training and interprofessional collaboration on the interobserver variation in the delineation of the lung gross tumor volume (GTVp) and lymph node (GTVln). MATERIAL AND METHODS: Eight target volume delineations courses were organized between 2008 and 2013. Specialists and trainees in radiation oncology were asked to delineate the GTVp and GTVln on four representative CT images of a patient diagnosed with lung cancer individually prior each course (baseline), together as group (interprofessional collaboration) and post-training. The mean delineated volume and local standard deviation (local SD) between the contours for each course group were calculated and compared with the expert delineations. RESULTS: A total 410 delineations were evaluated. The average local SD was lowest for the interprofessional collaboration (GTVp = 0.194 cm, GTVln = 0.371 cm) followed by the post-training (GTVp = 0.244 cm, GTVln = 0.607 cm) and baseline delineations (GTVp = 0.274 cm, GTVln: 0.718 cm). The mean delineated volume was smallest for the interprofessional (GTVp = 4.93 cm3, GTVln = 4.34 cm3) followed by the post-training (GTVp = 5.68 cm3, GTVln = 5.47 cm3) and baseline delineations (GTVp = 6.65 cm3, GTVln = 6.93 cm3). All delineations were larger than the expert for both GTVp and GTVln (p < .001). CONCLUSION: Our findings indicate that image interpretational differences can lead to large interobserver variation particularly when delineating the GTVln. Interprofessional collaboration was found to have the greatest impact on reducing interobserver variation in the delineation of the GTVln. This highlights the need to develop a clinical workflow so as to ensure that difficult cases are reviewed routinely by a second radiation oncologist or radiologist so as to minimize the risk of geographical tumor miss and unnecessary irradiation to normal tissue.


Asunto(s)
Competencia Clínica , Conducta Cooperativa , Neoplasias Pulmonares/patología , Oncólogos de Radiación/educación , Radioterapia Guiada por Imagen/normas , Carga Tumoral , Competencia Clínica/normas , Competencia Clínica/estadística & datos numéricos , Educación Médica , Marcadores Fiduciales , Fluorodesoxiglucosa F18 , Humanos , Comunicación Interdisciplinaria , Neoplasias Pulmonares/epidemiología , Neoplasias Pulmonares/radioterapia , Variaciones Dependientes del Observador , Tomografía Computarizada por Tomografía de Emisión de Positrones/métodos , Oncólogos de Radiación/normas , Oncólogos de Radiación/estadística & datos numéricos , Planificación de la Radioterapia Asistida por Computador/métodos , Planificación de la Radioterapia Asistida por Computador/estadística & datos numéricos , Errores de Configuración en Radioterapia/estadística & datos numéricos , Radioterapia Guiada por Imagen/estadística & datos numéricos , Entrenamiento Simulado/normas , Entrenamiento Simulado/estadística & datos numéricos
4.
Acta Oncol ; 58(6): 943-950, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30905243

RESUMEN

Objective: Delineation variation of esophageal tumors remains a large source of geometric uncertainty. In the present study, we investigated the inter- and intra-observer variation in esophageal gross tumor volume (GTV) delineation and the impact of endoscopically implanted fiducial markers on these variations. Material/Methods: Ten esophageal cancer patients with at least two markers endoscopically implanted at the cranial and caudal tumor borders and visible on the planning computed tomography (pCT) were included in this study. Five dedicated gastrointestinal radiation oncologists independently delineated GTVs on the pCT without markers and with markers. The GTV was first delineated on pCTs where markers were digitally removed and next on the original pCT with markers. Both delineation series were executed twice to determine intra-observer variation. For both the inter- and intra-observer analyses, the generalized conformity index (CIgen), and the standard deviation (SD) of the distances between delineated surfaces (i.e., overall, longitudinal, and radial SDs) were calculated. Linear mixed-effect models were used to compare the without and with markers series (α = 0.05). Results: Both the inter- and intra-observer CIgen were significantly larger in the series with markers than in the series without markers (p < .001). For the series without markers vs. with markers, the inter-observer overall SD, longitudinal SD, and radial SD was 0.63 cm vs. 0.22 cm, 1.44 cm vs. 0.42 cm, and 0.26 cm vs. 0.18 cm, respectively (p < .05); moreover, the intra-observer overall SD, longitudinal SD, and radial SD was 0.45 cm vs. 0.26 cm, 1.10 cm vs. 0.41 cm, and 0.22 cm vs. 0.15 cm, respectively (p < .05). Conclusion: The presence of markers at the cranial and caudal tumor borders significantly reduced both inter- and intra-observer GTV delineation variation, especially in the longitudinal direction. Our results endorse the use of markers in GTV delineation for esophageal cancer patients.


Asunto(s)
Adenocarcinoma/radioterapia , Carcinoma de Células Escamosas/radioterapia , Neoplasias Esofágicas/radioterapia , Marcadores Fiduciales , Variaciones Dependientes del Observador , Radioterapia/normas , Adenocarcinoma/metabolismo , Adenocarcinoma/patología , Anciano , Anciano de 80 o más Años , Carcinoma de Células Escamosas/metabolismo , Carcinoma de Células Escamosas/patología , Neoplasias Esofágicas/metabolismo , Neoplasias Esofágicas/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Pronóstico , Planificación de la Radioterapia Asistida por Computador/métodos , Estudios Retrospectivos , Tasa de Supervivencia , Tomografía Computarizada por Rayos X/métodos
5.
J Appl Clin Med Phys ; 20(1): 43-49, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30371972

RESUMEN

PURPOSE: For the 1.5 T Elekta MR-Linac it is essential that the optimisation of a treatment plan accounts for the electron return effect on the planned dose distribution. The ability of two algorithms for the first stage fluence optimisation, pencil beam (PB) and Monte Carlo (MC), to produce acceptable plan quality was investigated. Optimisation time for each algorithm was also compared. METHODS: Ten head and neck patients, ten lung patients and five prostate patients were selected from the clinical archive. These were retrospectively planned using a research version of Monaco with both the PB and MC algorithms for the fluence optimisation stage. After full optimisation DVH parameters, optimisation time and the number of Monitor Units (MU) as a measure of plan complexity were extracted. RESULTS: There were no clinically significant differences between any of the DVH parameters studied or the total number of MUs between using PB or MC for stage 1 optimisation across the three patient groups. However, planning time increased by a factor of ten using MC algorithms for stage 1. CONCLUSION: The use of MC calculations compared to PB, for stage 1 fluence optimisation, results in increased planning time without clinical improvement in plan quality or reduction in complexity and is therefore not necessary.


Asunto(s)
Neoplasias de Cabeza y Cuello/radioterapia , Neoplasias Pulmonares/radioterapia , Aceleradores de Partículas/instrumentación , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/normas , Humanos , Masculino , Método de Montecarlo , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/métodos , Estudios Retrospectivos
6.
J Neurooncol ; 139(3): 591-598, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29777418

RESUMEN

BACKGROUND: Detection of glioblastoma progression is important for clinical decision-making on cessation or initiation of therapy, for enrollment in clinical trials, and for response measurement in time and location. The RANO-criteria are considered standard for the timing of progression. To evaluate local treatment, we aim to find the most accurate progression location. We determined the differences in progression free survival (PFS) and in tumor volumes at progression (Vprog) by three definitions of progression. METHODS: In a consecutive cohort of 73 patients with newly-diagnosed glioblastoma between 1/1/2012 and 31/12/2013, progression was established according to three definitions. We determined (1) earliest radiological progression (ERP) by retrospective multidisciplinary consensus review using all available imaging and follow-up, (2) clinical practice progression (CPP) from multidisciplinary tumor board conclusions, and (3) progression by the RANO-criteria. RESULTS: ERP was established in 63 (86%), CPP in 64 (88%), RANO progression in 42 (58%). Of the 63 patients who had died, 37 (59%) did with prior RANO-progression, compared to 57 (90%) for both ERP and CPP. The median overall survival was 15.3 months. The median PFS was 8.8 months for ERP, 9.5 months for CPP, and 11.8 months for RANO. The PFS by ERP was shorter than CPP (HR 0.57, 95% CI 0.38-0.84, p = 0.004) and RANO-progression (HR 0.29, 95% CI 0.19-0.43, p < 0.001). The Vprog were significantly smaller for ERP (median 8.8 mL), than for CPP (17 mL) and RANO (22 mL). CONCLUSION: PFS and Vprog vary considerably between progression definitions. Earliest radiological progression by retrospective consensus review should be considered to accurately localize progression and to address confounding of lead time bias in clinical trial enrollment.


Asunto(s)
Neoplasias Encefálicas/diagnóstico por imagen , Glioblastoma/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Neoplasias Encefálicas/mortalidad , Neoplasias Encefálicas/fisiopatología , Neoplasias Encefálicas/terapia , Consenso , Progresión de la Enfermedad , Supervivencia sin Enfermedad , Femenino , Estudios de Seguimiento , Glioblastoma/mortalidad , Glioblastoma/fisiopatología , Glioblastoma/terapia , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
7.
Acta Oncol ; 57(8): 1038-1042, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29630433

RESUMEN

AIMS: This feasibility study aimed to identify relationships between radiation doses to the masticatory apparatus as a combined block or as individual subunits with changes in trismus following radiotherapy. MATERIAL AND METHODS: Twenty patients from a single center were recruited prospectively as part of a randomized trial comparing proactive exercises in the management of trismus. Patients with stage III/IV oral cavity or oropharyngeal squamous cell cancers received intensity-modulated radiotherapy with concurrent systemic therapy. All patients had trismus prior to radiotherapy. Maximal inter-incisor distance (MID) was measured pre- and 6 months from the start of radiotherapy. Bilateral muscles of mastication: medial and lateral pterygoids (MP and LP), masseters (M), temporalis (T), temporomandibular joint (TMJ) were contoured on CT images. The block comprised all muscles excluding the TMJ below the orbital floor. Mean dose, equivalent uniform dose (EUD) and V35-V60 Gy were compared with change in MID. RESULTS: In six patients, the MID deteriorated at 6 months from the start of radiotherapy compared with 14 whose MID improved. No significant association was observed between age, gender, smoking, alcohol status, exercise compliance, cisplatin, tumor site, stage, V35-V60 Gy or EUD with change in MID. A clinical outlier was excluded. Without the outlier (n = 19), a significant association was seen between mean dose and change in MID at 6 months for the ipsilateral block (p = .01), LP (p = .04) and M (p < .01). All patients where trismus deteriorated at 6 months received mean doses >40 Gy to the block. CONCLUSION: Higher mean radiation doses to the ipsilateral block, LP and M were significantly associated with deterioration in trismus. Limiting dose to these structures to ≤40 Gy for tumors not invading the masticatory muscles may improve treatment-related sequelae. The ipsilateral block, LP and M should be studied further as possible alternative avoidance structures in radiotherapy treatment planning.


Asunto(s)
Masticación/efectos de la radiación , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada/efectos adversos , Trismo/etiología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Músculos Masticadores/diagnóstico por imagen , Músculos Masticadores/efectos de la radiación , Neoplasias de Células Escamosas/diagnóstico por imagen , Neoplasias de Células Escamosas/radioterapia , Neoplasias Orofaríngeas/diagnóstico por imagen , Neoplasias Orofaríngeas/radioterapia , Estudios Prospectivos , Enfermedades Estomatognáticas/etiología , Articulación Temporomandibular/diagnóstico por imagen , Articulación Temporomandibular/efectos de la radiación
8.
Lancet Oncol ; 18(10): 1348-1359, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28802802

RESUMEN

BACKGROUND: In patients with squamous cell carcinoma of the anus (SCCA), lymph node positivity (LNP) indicates poor prognosis for survival and is central to radiotherapy planning. Over the past three decades, LNP proportion has increased, mainly reflecting enhanced detection with newer imaging modalities; a process known as nodal stage migration. If accompanied by constant T stage distributions, prognosis for both lymph node-positive and lymph node-negative groups may improve without any increase in overall survival for individual patients; a paradox termed the Will Rogers phenomenon. Here, we aim to systematically evaluate the impact of nodal stage migration on survival in SCCA and address a novel hypothesis that this phenomenon results in reduced prognostic discrimination. METHODS: We did a systematic review and meta-regression to quantify changes in LNP over time and the impact of this change on survival and prognostic discrimination. We searched MEDLINE, Embase, and the Cochrane Library to identify randomised trials and observational studies in patients with SCCA published between Jan 1, 1970, and Oct 11, 2016. Studies were eligible if patients received chemoradiotherapy or radiotherapy as the main treatment, reported LNP proportions (all studies), and reported overall survival (not necessarily present in all studies). We excluded studies with fewer than 50 patients. We extracted study-level data with a standardised, piloted form. The primary outcome measure was 5-year overall survival. To investigate scenarios in which reduced prognostic discrimination might occur, we simulated varying true LNP proportions and true overall survival, and compared these with expected observed outcomes for varying levels of misclassification of true nodal state. FINDINGS: We identified 62 studies reporting LNP proportions, which included 10 569 patients. From these, we included 45 studies (6302 patients) with whole cohort 5-year overall survival, 11 studies with 5-year survival stratified by nodal status, and 20 studies with hazard ratios in our analyses of temporal changes. In 62 studies, the LNP proportions increased from a mean estimate of 15·3% (95% CI 10·5-20·1) in 1980 to 37·1% (34·0-41·3) in 2012 (p<0·0001). In 11 studies with prognostic data, increasing LNP was associated with improved overall survival in both lymph node-positive and lymph node-negative categories, whereas the proportions with combined tumour stage T3 and T4 remained constant. In 20 studies, across a range of LNP proportions from 15% to 40%, the hazard ratios for overall survival of lymph node-positive versus lymph node-negative patients decreased significantly from 2·5 (95% CI 1·8-3·3) at 15% LNP to 1·3 (1·2-1·9; p=0·014) at 40% LNP. The simulated scenarios reproduced this effect if the true LNP proportions were 20% or 25%, but not if the true LNP proportions were 30% or greater. INTERPRETATION: We describe a consequence of staging misclassification in anal cancer that we have termed reduced prognostic discrimination. We used this new observation to infer that the LNP proportions of more than 30% seen in modern clinical series (11 out of 15 studies with a median year since 2007) are higher than the true LNP proportion. The introduction of new staging technologies in oncology might misclassify true disease stage, spuriously informing disease management and ultimately increasing the risk of overtreatment. FUNDING: Bowel Disease Research Foundation.


Asunto(s)
Neoplasias del Ano/mortalidad , Neoplasias del Ano/patología , Carcinoma de Células Escamosas/mortalidad , Carcinoma de Células Escamosas/patología , Escisión del Ganglio Linfático/métodos , Ganglios Linfáticos/patología , Anciano , Neoplasias del Ano/terapia , Carcinoma de Células Escamosas/terapia , Causas de Muerte , Quimioradioterapia/métodos , Ensayos Clínicos Fase III como Asunto , Supervivencia sin Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Invasividad Neoplásica/patología , Estadificación de Neoplasias , Pronóstico , Análisis de Supervivencia , Resultado del Tratamiento
9.
Acta Oncol ; 56(7): 923-930, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-28375667

RESUMEN

PURPOSE: To assess the effect of additional magnetic resonance imaging (MRI) alongside the planning computed tomography (CT) scan on target volume delineation in pancreatic cancer patients. MATERIAL AND METHODS: Eight observers (radiation oncologists) from six institutions delineated the gross tumor volume (GTV) on 3DCT, and internal GTV (iGTV) on 4DCT of four pancreatic cancer patients, while MRI was available in a second window (CT + MRI). Variations in volume, generalized conformity index (CIgen), and overall observer variation, expressed as standard deviation (SD) of the distances between delineated surfaces, were analyzed. CIgen is a measure of overlap of the delineated iGTVs (1 = full overlap, 0 = no overlap). Results were compared with those from an earlier study that assessed the interobserver variation by the same observers on the same patients on CT without MRI (CT-only). RESULTS: The maximum ratios between delineated volumes within a patient were 6.1 and 22.4 for the GTV (3DCT) and iGTV (4DCT), respectively. The average (root-mean-square) overall observer variations were SD = 0.41 cm (GTV) and SD = 0.73 cm (iGTV). The mean CIgen was 0.36 for GTV and 0.37 for iGTV. When compared to the iGTV delineated on CT-only, the mean volumes of the iGTV on CT + MRI were significantly smaller (32%, Wilcoxon signed-rank, p < .0005). The median volumes of the iGTV on CT + MRI were included for 97% and 92% in the median volumes of the iGTV on CT. Furthermore, CT + MRI showed smaller overall observer variations (root-mean-square SD = 0.59 cm) in six out of eight delineated structures compared to CT-only (root-mean-square SD = 0.72 cm). However, large local observer variations remained close to biliary stents and pathological lymph nodes, indicating issues with instructions and instruction compliance. CONCLUSIONS: The availability of MRI images during target delineation of pancreatic cancer on 3DCT and 4DCT resulted in smaller target volumes and reduced the interobserver variation in six out of eight delineated structures.


Asunto(s)
Tomografía Computarizada Cuatridimensional/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Neoplasias Pancreáticas/patología , Tomografía Computarizada por Rayos X/métodos , Quimioradioterapia , Estudios de Factibilidad , Estudios de Seguimiento , Humanos , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/terapia , Pronóstico
10.
J Biomed Inform ; 65: 145-158, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27932222

RESUMEN

Sensemaking theories help designers understand the cognitive processes of a user when he/she performs a complicated task. This paper introduces a two-step approach of incorporating sensemaking support within the design of health information systems by: (1) modeling the sensemaking process of physicians while performing a task, and (2) identifying software interaction design requirements that support sensemaking based on this model. The two-step approach is presented based on a case study of the tumor contouring clinical task for radiotherapy planning. In the first step of the approach, a contextualized sensemaking model was developed to describe the sensemaking process based on the goal, the workflow and the context of the task. In the second step, based on a research software prototype, an experiment was conducted where three contouring tasks were performed by eight physicians respectively. Four types of navigation interactions and five types of interaction sequence patterns were identified by analyzing the gathered interaction log data from those twenty-four cases. Further in-depth study on each of the navigation interactions and interaction sequence patterns in relation to the contextualized sensemaking model revealed five main areas for design improvements to increase sensemaking support. Outcomes of the case study indicate that the proposed two-step approach was beneficial for gaining a deeper understanding of the sensemaking process during the task, as well as for identifying design requirements for better sensemaking support.


Asunto(s)
Cognición , Sistemas de Información en Salud , Neoplasias , Programas Informáticos , Comprensión , Femenino , Humanos , Masculino , Modelos Teóricos
11.
Acta Oncol ; 54(6): 839-46, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25591817

RESUMEN

BACKGROUND: The efficacy of focal continuous low dose-rate brachytherapy (CLDR-BT) for prostate cancer requires that appropriate margins are applied to ensure robust target coverage. In this study we propose a method to establish such margins by emulating a focal treatment in patients treated with CLDR-BT to the entire gland. MATERIAL AND METHODS: In 15 patients with localized prostate cancer, prostate volumes and dominant intra-prostatic lesions were delineated on pre-treatment magnetic resonance imaging (MRI). Delineations and MRI were registered to trans-rectal ultrasound images in the operating theater. The patients received CLDR-BT treatment to the total prostate volume. The implantation consisted of two parts: an experimental focal plan covering the dominant intra-prostatic lesion (F-GTV), followed by a plan containing additional seeds to achieve entire prostate coverage. Isodose surfaces were reconstructed using follow-up computed tomography (CT). The focal dose was emulated by reconstructing seeds from the focal plan only. The distance to agreement between planned and delivered isodose surfaces and F-GTV coverage was determined to calculate the margin required for robust treatment. RESULTS: If patients had been treated only focally, the target volume would have been reduced from an average of 40.9 cm3 for the entire prostate to 5.8 cm3 for the focal plan. The D90 for the F-GTV in the focal plan was 195±60 Gy, the V100 was 94% [range 71-100%]. The maximum distance (cd95) between the planned and delivered isodose contours was 0.48 cm. CONCLUSIONS: This study provides an estimate of 0.5 cm for the margin required for robust coverage of a focal target volume prior to actually implementing a focal treatment protocol.


Asunto(s)
Braquiterapia/métodos , Radioisótopos de Yodo/uso terapéutico , Neoplasias de la Próstata/radioterapia , Humanos , Imagen por Resonancia Magnética , Masculino , Tamaño de los Órganos , Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador , Carga Tumoral , Ultrasonografía , Incertidumbre
12.
J Appl Clin Med Phys ; 16(3): 5375, 2015 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-26103497

RESUMEN

Portal dosimetry using electronic portal imaging devices (EPIDs) is often applied to verify high-energy photon beam treatments. Due to the change in photon energy spectrum, the resulting dose values are, however, not very accurate in the case of wedged beams if the pixel-to-dose conversion for the situation without wedge is used. A possible solution would be to consider a wedged beam as another photon beam quality requiring separate beam modeling of the dose calculation algorithm. The aim of this study was to investigate a more practical solution: to make aSi EPID-based dosimetry models also applicable for wedged beams without an extra commissioning effort of the parameters of the model. For this purpose two energy-dependent wedge multiplication factors have been introduced to be applied for portal images taken with and without a patient/phantom in the beam. These wedge multiplication factors were derived from EPID and ionization chamber measurements at the EPID level for wedged and nonwedged beams, both with and without a polystyrene slab phantom in the beam. This method was verified for an EPID dosimetry model used for wedged beams at three photon beam energies (6, 10, and 18 MV) by comparing dose values reconstructed in a phantom with data provided by a treatment planning system (TPS), as a function of field size, depth, and off-axis distance. Generally good agreement, within 2%, was observed for depths between dose maximum and 15 cm. Applying the new model to EPID dose measurements performed during ten breast cancer patient treatments with wedged 6 MV photon beams showed that the average isocenter underdosage of 5.3% was reduced to 0.4%. Gamma-evaluation (global 3%/3 mm) of these in vivo data showed an increase in percentage of points with γ ≤ 1 from 60.2% to 87.4%, while γmean reduced from 1.01 to 0.55. It can be concluded that, for wedged beams, the multiplication of EPID pixel values with an energy-dependent correction factor provides good agreement between dose values determined by an EPID and a TPS, indicating the usefulness of such a practical solution.


Asunto(s)
Algoritmos , Radiometría/instrumentación , Radiometría/métodos , Radioterapia de Alta Energía/instrumentación , Radioterapia de Alta Energía/métodos , Pantallas Intensificadoras de Rayos X , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
14.
Eur J Epidemiol ; 29(4): 293-301, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24748424

RESUMEN

Computed tomography (CT) scans are indispensable in modern medicine; however, the spectacular rise in global use coupled with relatively high doses of ionizing radiation per examination have raised radiation protection concerns. Children are of particular concern because they are more sensitive to radiation-induced cancer compared with adults and have a long lifespan to express harmful effects which may offset clinical benefits of performing a scan. This paper describes the design and methodology of a nationwide study, the Dutch Pediatric CT Study, regarding risk of leukemia and brain tumors in children after radiation exposure from CT scans. It is a retrospective record-linkage cohort study with an expected number of 100,000 children who received at least one electronically archived CT scan covering the calendar period since the introduction of digital archiving until 2012. Information on all archived CT scans of these children will be obtained, including date of examination, scanned body part and radiologist's report, as well as the machine settings required for organ dose estimation. We will obtain cancer incidence by record linkage with external databases. In this article, we describe several approaches to the collection of data on archived CT scans, the estimation of radiation doses and the assessment of confounding. The proposed approaches provide useful strategies for data collection and confounder assessment for general retrospective record-linkage studies, particular those using hospital databases on radiological procedures for the assessment of exposure to ionizing or non-ionizing radiation.


Asunto(s)
Neoplasias Encefálicas/epidemiología , Bases de Datos Factuales , Leucemia/epidemiología , Registro Médico Coordinado , Dosis de Radiación , Tomografía Computarizada por Rayos X/efectos adversos , Adolescente , Niño , Preescolar , Estudios de Seguimiento , Humanos , Incidencia , Lactante , Masculino , Neoplasias Inducidas por Radiación/epidemiología , Países Bajos/epidemiología , Pediatría , Radiación Ionizante , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores Socioeconómicos , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
15.
Br J Radiol ; 97(1156): 757-762, 2024 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-38407369

RESUMEN

OBJECTIVES: Metallic implants cause artefacts and distortion on MRI. To ensure accurate dose delivery and plan adaptation on an MR Linac, there is a need to evaluate distortion caused. METHODS: Participants were imaged on an MR Linac (Elekta Unity, Elekta AB Stockholm). Three sequences were evaluated. Two vendor supplied (T2W TSE 3D), and one T2W TSE 3D optimized to reduce metal artefact distortions. Images were rigidly registered to CT images by a single observer, using bony anatomy. Three coronal and three axial images were selected, and six paired, adjacent, bony landmarks were identified on each slice. Images bisecting treatment isocentre were included. Difference between landmark coordinates was taken to be measure of distortion. RESULTS: Five observers participated. Thirty six pairs of bony landmarks were identified. Median difference in position of landmarks was ≤3 mm (range 0.3-4.4 mm). One-way analysis of variance (ANOVA) between observer means showed no significant variation between sequences or patients (P = 1.26 in plane, P = 0.11 through plane). Interobserver intra class correlation (ICC) was 0.70 in-plane and 0.78 through-plane. Intra-observer ICC for three observers was 0.76, 0.81, 0.83, showing moderate to good reliability on this small cohort. CONCLUSIONS: This in-vivo feasibility study suggests distortion due to metallic hip prosthesis is not an obstacle for pelvic radiotherapy on an MR Linac. Research on the impact on plan quality is warranted. ADVANCES IN KNOWLEDGE: This work supports feasibility of treating patients with metallic hip prosthesis on an MR Linac.


Asunto(s)
Prótesis de Cadera , Neoplasias de la Próstata , Masculino , Humanos , Prótesis de Cadera/efectos adversos , Reproducibilidad de los Resultados , Imagen por Resonancia Magnética/métodos , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Fantasmas de Imagen , Aceleradores de Partículas
16.
BJR Open ; 6(1): tzae006, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38737623

RESUMEN

Objectives: We validated an auto-contouring algorithm for heart substructures in lung cancer patients, aiming to establish its accuracy and reliability for radiotherapy (RT) planning. We focus on contouring an amalgamated set of subregions in the base of the heart considered to be a new organ at risk, the cardiac avoidance area (CAA), to enable maximum dose limit implementation in lung RT planning. Methods: The study validates a deep-learning model specifically adapted for auto-contouring the CAA (which includes the right atrium, aortic valve root, and proximal segments of the left and right coronary arteries). Geometric, dosimetric, quantitative, and qualitative validation measures are reported. Comparison with manual contours, including assessment of interobserver variability, and robustness testing over 198 cases are also conducted. Results: Geometric validation shows that auto-contouring performance lies within the expected range of manual observer variability despite being slightly poorer than the average of manual observers (mean surface distance for CAA of 1.6 vs 1.2 mm, dice similarity coefficient of 0.86 vs 0.88). Dosimetric validation demonstrates consistency between plans optimized using auto-contours and manual contours. Robustness testing confirms acceptable contours in all cases, with 80% rated as "Good" and the remaining 20% as "Useful." Conclusions: The auto-contouring algorithm for heart substructures in lung cancer patients demonstrates acceptable and comparable performance to human observers. Advances in knowledge: Accurate and reliable auto-contouring results for the CAA facilitate the implementation of a maximum dose limit to this region in lung RT planning, which has now been introduced in the routine setting at our institution.

17.
Radiother Oncol ; 190: 109963, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38406888

RESUMEN

BACKGROUND: Implementation of daily cone-beam CT (CBCT) into clinical practice in paediatric image-guided radiotherapy (IGRT) lags behind compared to adults. Surveys report wide variation in practice for paediatric IGRT and technical information remains unreported. In this study we report on technical settings from applied paediatric CBCT protocols and review the literature for paediatric CBCT protocols. METHODS: From September to October 2022, a survey was conducted among 246 SIOPE-affiliated centres across 35 countries. The survey consisted of 3 parts: 1) baseline information; technical CBCT exposure settings and patient set-up procedure for 2) brain/head, and 3) abdomen. Descriptive statistics was used to summarise current practice. The literature was reviewed systematically with two reviewers obtaining consensus RESULTS: The literature search revealed 22 papers concerning paediatric CBCT protocols. Seven papers focused on dose-optimisation. Responses from 50/246 centres in 25/35 countries were collected: 44/50 treated with photons and 10/50 with protons. In total, 48 brain/head and 53 abdominal protocols were reported. 42/50 centres used kV-CBCT for brain/head and 35/50 for abdomen; daily CBCT was used for brain/head = 28/48 (58%) and abdomen = 33/53 62%. Greater consistency was seen in brain/head protocols (dose range 0.32 - 67.7 mGy) compared to abdominal (dose range 0.27 - 119.7 mGy). CONCLUSION: Although daily CBCT is now widely used in paediatric IGRT, our survey demonstrates a wide range of technical settings, suggesting an unmet need to optimise paediatric IGRT protocols. This is in accordance with the literature. However, there are only few paediatric optimisation studies suggesting that dose reduction is possible while maintaining image quality.


Asunto(s)
Radioterapia Guiada por Imagen , Tomografía Computarizada de Haz Cónico Espiral , Adulto , Humanos , Niño , Radioterapia Guiada por Imagen/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Abdomen , Tomografía Computarizada de Haz Cónico/métodos , Europa (Continente) , Fantasmas de Imagen , Dosificación Radioterapéutica , Literatura de Revisión como Asunto
18.
Radiother Oncol ; 193: 110113, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38301958

RESUMEN

BACKGROUND AND PURPOSE: Radiation induced cardiotoxicity (RICT) is as an important sequela of radiotherapy to the thorax for patients. In this study, we aim to investigate the dose and fractionation response of RICT. We propose global longitudinal strain (GLS) as an early indicator of RICT and investigate myocardial deformation following irradiation. METHODS: RICT was investigated in female C57BL/6J mice in which the base of the heart was irradiated under image-guidance using a small animal radiation research platform (SARRP). Mice were randomly assigned to a treatment group: single-fraction dose of 16 Gy or 20 Gy, 3 consecutive fractions of 8.66 Gy, or sham irradiation; biological effective doses (BED) used were 101.3 Gy, 153.3 Gy and 101.3 Gy respectively. Longitudinal transthoracic echocardiography (TTE) was performed from baseline up to 50 weeks post-irradiation to detect structural and functional effects. RESULTS: Irradiation of the heart base leads to BED-dependent changes in systolic and diastolic function 50 weeks post-irradiation. GLS showed significant decreases in a BED-dependent manner for all irradiated animals, as early as 10 weeks after irradiation. Early changes in GLS indicate late changes in cardiac function. BED-independent increases were observed in the left ventricle (LV) mass and volume and myocardial fibrosis. CONCLUSIONS: Functional features of RICT displayed a BED dependence in this study. GLS showed an early change at 10 weeks post-irradiation. Cardiac remodelling was observed as increases in mass and volume of the LV, further supporting our hypothesis that dose to the base of the heart drives the global heart toxicity.


Asunto(s)
Corazón , Miocardio , Humanos , Femenino , Animales , Ratones , Ratones Endogámicos C57BL , Corazón/efectos de la radiación , Ecocardiografía , Cardiotoxicidad/etiología
19.
J Thorac Oncol ; 18(5): 599-607, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36738929

RESUMEN

INTRODUCTION: The RTOG 0617 trial presented a worse survival for patients with lung cancer treated in the high-dose (74 Gy) arm. In multivariable models, radiation level and whole-heart volumetric dose parameters were associated with survival. In this work, we consider heart subregions to explain the observed survival difference between radiation levels. METHODS: Voxel-based analysis identified anatomical regions where the dose was associated with survival. Bootstrapping clinical and dosimetric variables into an elastic net model selected variables associated with survival. Multivariable Cox regression survival models assessed the significance of dose to the heart subregion, compared with whole heart v5 and v30. Finally, the trial outcome was assessed after propensity score matching of patients on lung dose, heart subregion dose, and tumor volume. RESULTS: A total of 458 patients were eligible for voxel-based analysis. A region of significance (p < 0.001) was identified in the base of the heart. Bootstrapping selected mean lung dose, radiation level, log tumor volume, and heart region dose. The multivariable Cox model exhibited dose to the heart region (p = 0.02), and tumor volume (p = 0.03) were significantly associated with survival, and radiation level was not significant (p = 0.07). The models exhibited that whole heart v5 and v30 were not associated with survival, with radiation level being significant (p < 0.05). In the matched cohort, no significant survival difference was seen between radiation levels. CONCLUSIONS: Dose to the base of the heart is associated with overall survival, partly removing the radiation level effect, and explaining that worse survival in the high-dose arm is owing, in part, to the heart subregion dose. By defining a heart avoidance region, future dose escalation trials may be feasible.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Neoplasias Pulmonares , Traumatismos por Radiación , Humanos , Neoplasias Pulmonares/patología , Carcinoma de Pulmón de Células no Pequeñas/patología , Pulmón/patología , Radiometría , Dosificación Radioterapéutica
20.
Phys Med ; 109: 102579, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37068428

RESUMEN

PURPOSE: In addition to patient set-up uncertainties, anatomical deformations, e.g., weight loss, lead to time-dependent differences between the planned and delivered dose in a radiotherapy course that currently cannot easily be predicted. The aim of this study was to create time-varying prediction models to describe both the average and residual anatomical deformations. METHODS: Weekly population-based principal component analysis models were generated from on-treatment cone-beam CT scans (CBCTs) of 30 head and neck cancer patients, with additional data of 35 patients used as a validation cohort. We simulated treatment courses accounting for a) anatomical deformations, b) set-up uncertainties and c) a combination of both. The dosimetric effects of the simulated deformations were compared to a direct dose accumulation based on deformable registration of the CBCT data. RESULTS: Set-up uncertainties were seen to have a larger effect on the organ at risk (OAR) doses than anatomical deformations for all OARs except the larynx and the primary CTV. Distributions from simulation results were in good agreement with those of the accumulated dose. CONCLUSIONS: We present a novel method of modelling time-varying organ deformations in head and neck cancer. The effect on the OAR doses from these deformations are smaller than the effect of set-up uncertainties for most OARs. These models can, for instance, be used to predict which patients could benefit from adaptive radiotherapy, prior to commencing treatment.


Asunto(s)
Neoplasias de Cabeza y Cuello , Radioterapia de Intensidad Modulada , Humanos , Radioterapia de Intensidad Modulada/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Neoplasias de Cabeza y Cuello/radioterapia , Dosificación Radioterapéutica , Tomografía Computarizada de Haz Cónico/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA