Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
3.
Cornea ; 42(9): 1074-1082, 2023 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36730371

RESUMEN

PURPOSE: The aim of this study was to explore video-graded intraoperative risk factors for graft detachment (GD) and rebubbling in Descemet membrane endothelial keratoplasty surgery. METHODS: A post hoc analysis of 65 eyes of 65 pseudophakic subjects with Fuchs endothelial dystrophy that underwent Descemet membrane endothelial keratoplasty surgery as part of the Advanced Visualization In Corneal Surgery Evaluation trial. All surgical recordings were assessed by 2 graders using a structured assessment form. A multinominal regression was performed to estimate the independent effect of video-graded intraoperative factors on the incidence of GD and rebubbling. Secondary outcomes are corrected distance visual acuity and endothelial cell density. RESULTS: In total, 33 GDs were recorded, of which 17 required rebubbling. No significant predictors for GD or rebubbling were identified. However, the results revealed 2 clinically relevant patterns. An unfavorable graft configuration (ie, wrinkled, tight scroll, or taco-shaped) and a gas-bubble size smaller than the graft diameter were associated with an increased risk of GD [odds ratio (OR) 2.5 and OR 2.26, respectively] and rebubbling (OR 2.0 and OR 2.60, respectively). Inversely, a larger gas-bubble size was associated with a reduced risk of GD (OR 0.37) and rebubbling (OR 0.36). At 3 and 6 months postoperatively, corrected distance visual acuity was poorer in subjects requiring a rebubbling and endothelial cell density loss was higher in subjects with a partial GD. CONCLUSIONS: Our analysis revealed that the gas-bubble size and graft shape/geometry seem to be relevant clinical factors for GD and rebubbling, whereas descemetorhexis difficulty, degree of graft manipulation, graft overlap, and surgical iridectomy were not associated with an increased risk.


Asunto(s)
Queratoplastia Endotelial de la Lámina Limitante Posterior , Distrofia Endotelial de Fuchs , Cirujanos , Humanos , Recuento de Células , Lámina Limitante Posterior/cirugía , Queratoplastia Endotelial de la Lámina Limitante Posterior/métodos , Endotelio Corneal , Distrofia Endotelial de Fuchs/cirugía , Estudios Retrospectivos
4.
Ophthalmol Ther ; 12(6): 3347-3359, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37843772

RESUMEN

INTRODUCTION: Allogeneic serum from blood donors is starting to be used to treat patients with dry eye disease (DED). However, the optimal dose is not known. We therefore aimed to evaluate the clinical efficaciousness and user-friendliness of micro-sized versus conventional-sized allogeneic serum eye drops (SEDs). METHODS: In a randomized trial, patients with DED first receive micro-sized SEDs (7 µl/unit) for 1 month, followed by a 1-month washout, before receiving conventional-sized SEDs (50 µl/unit) for 1 month; or vice versa. The primary endpoint was the Ocular Surface Disease Index (OSDI) score. Secondary endpoints were tear break-up time (TBT), tear production (TP), and presence of corneal punctate lesions (CP). The user-friendliness of both application systems was also compared. A linear mixed model for cross-over design was applied to compare both treatments. RESULTS: Forty-nine patients completed the trial. The mean OSDI score significantly improved from 52 ± 3 to 41 ± 3 for micro-sized SEDs, and from 54 ± 3 to 45 ± 3 for conventional-sized SEDs. Non-inferiority (margin = 6) of micro-sized SEDs was established. We demonstrate a significant improvement for TBT in case of conventional-sized SEDs and for CP in both treatment groups. TP trended towards an improvement in both treatment groups. The user-friendliness of the conventional drop system was significantly higher. CONCLUSIONS: For the first time, non-inferiority of micro-sized allogeneic SEDs was established. The beneficial effect of both SED volumes was similar as measured by the OSDI score. Although user-friendliness of the micro drop system was significantly lower, it is an attractive alternative as it saves valuable donor serum. TRIAL REGISTRATION: ClinicalTrials.gov (NCT03539159).

5.
Cell Tissue Bank ; 13(2): 333-9, 2012 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21637991

RESUMEN

The aim of this study was to report the efficacy of adding chlorhexidine to the protocol for decontamination of human donor globes prior to excision of corneo-scleral rims for future keratoplasty procedures. In 2005, chlorhexidine was introduced by our eye bank as an additional step in the protocol for decontaminating human donor globes. After 5 years, we prospectively evaluated the number of contaminations. Out of 2,891 globes included in our study, 2,663 globes were processed, of which 36 (1.4%) were considered contaminated. Seventeen contaminations (0.6%) were detected by culturing limbal swabs, directly after decontamination, eight (0.3%) by visible discoloration of the culture medium carrying a corneo-scleral rim, and eleven (0.4%) after inoculation of the culture medium on blood agar plates. Importantly, after 4 weeks of incubation, none of the aerobic and anaerobic cultures taken from the secondary 'transport medium' (dextran containing medium used to transport corneal tissue to the transplantation centre) showed microbiological growth. In conclusion, the combined use of 0.02% chlorhexidine and 0.5% povidone-iodine may allow decontamination of donor globes to a level at which the risk of tissue contamination at the time of transplantation is minimized, while corneal viability is preserved.


Asunto(s)
Clorhexidina/farmacología , Córnea/efectos de los fármacos , Descontaminación/métodos , Bancos de Ojos , Povidona Yodada/farmacología , Preservación Biológica/métodos , Donantes de Tejidos , Bacterias/efectos de los fármacos , Bacterias/aislamiento & purificación , Humanos , Transportes
6.
Cornea ; 39(6): 674-679, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32141944

RESUMEN

PURPOSE: To evaluate the clinical value of intraoperative optical coherence tomography (iOCT) and prolonged overpressure in Descemet membrane endothelial keratoplasty for surgical safety, efficiency, and outcome. METHODS: All Descemet membrane endothelial keratoplasties performed by the same surgeon from November 2016 through April 2018 at the University Medical Center Utrecht were included, including 6 months of follow-up. The primary outcome was the prevalence of adverse events, and the secondary outcomes included critical decision-making and surgery time. Surgeries that included prolonged (ca. 12 minutes) overpressurization of the globe were classified as group 1, and those without prolonged overpressurization of the globe were classified as group 2. In all cases, iOCT was used to determine the graft orientation, apposition, and assessment of interface fluid. RESULTS: A total of 38 cases were included for analysis. In groups 1 and 2, 7 (43.6%) and 4 (18.1%) adverse events, respectively, were recorded (P = 0.29). Specifically, in groups 1 and 2, 4 and 3 cases, respectively, required rebubbling because of graft dislocation (P = 0.15). In 43% of surgeries, iOCT proved to be of value for surgical decision-making. Surgery time differed significantly between groups 1 and 2 (P < 0.001) and was the result of a shortened pressurization time in group 2. CONCLUSIONS: iOCT provides a direct assessment of the graft orientation and apposition, allowing the surgeon to refrain from prolonged pressurization of the globe after graft insertion. Optimizing the surgical protocol using iOCT can lead to a significant reduction in surgery time without compromising surgical safety or outcome.


Asunto(s)
Enfermedades de la Córnea/cirugía , Queratoplastia Endotelial de la Lámina Limitante Posterior/métodos , Monitoreo Intraoperatorio/métodos , Tomografía de Coherencia Óptica/métodos , Anciano , Enfermedades de la Córnea/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Masculino , Tempo Operativo , Estudios Prospectivos , Resultado del Tratamiento
7.
Ned Tijdschr Geneeskd ; 1632019 08 29.
Artículo en Holandés | MEDLINE | ID: mdl-31483581

RESUMEN

BACKGROUND Keeping exotic pets can lead to dangerous situations. We describe an ophthalmological injury caused by Palythoa, an anemone that produces palytoxin when irritated. Palytoxin is one of the most poisonous marine toxins ever described. CASE This case concerns a healthy, 44-year-old man who had rubbed his eyes after setting up a tropical aquarium, which contained sea-anemones among other species. This resulted in bilateral corneal melting, or keratolysis. The injury turned out to be caused by palytoxin. As a consequence, this patient was permanently visually impaired. CONCLUSION The anemone described in this case (Palythoasp) can easily be purchased online with no warnings whatsoever. When working with an aquarium, it is important to know about the species it contains and to wear protective clothing if necessary.


Asunto(s)
Lesiones Accidentales/inducido químicamente , Acrilamidas , Antozoos , Venenos de Cnidarios , Córnea , Lesiones de la Cornea/inducido químicamente , Adulto , Animales , Lesiones de la Cornea/complicaciones , Humanos , Masculino , Trastornos de la Visión/etiología
8.
Acta Ophthalmol ; 97(7): 714-720, 2019 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-30803143

RESUMEN

PURPOSE: Posterior lamellar corneal surgery is considered the standard of care for irreversible endothelial cell dysfunction. Pre-cut grafts can be prepared either manually (Descemet stripping endothelial keratoplasty; DSEK) or mechanically (Descemet stripping automated endothelial keratoplasty; DSAEK). We performed a head-to-head clinical comparison between DSEK and DSAEK grafts. METHODS: All DSEK and DSAEK procedures performed by two corneal specialists at the University Medical Center Utrecht from 1 January 2016 through 31 October 2016 were prospectively included. Pre-cut grafts were delivered by two eye banks, which either exclusively prepared the DSEK or DSAEK grafts. Preoperative and postoperative measurements were obtained, and all surgical events and adverse events were recorded. RESULTS: A total of 21 DSEK and 53 DSAEK procedures were included for analysis; the two groups were similar at baseline, with the exception of graft endothelial cell density, which was 2531 ± 67 versus 2748 ± 148 cells/mm2 , respectively (p < 0.001). At the one-year follow-up visit, corrected distance visual acuity and endothelial cell loss were similar between the groups. Mean pachymetry was significantly lower in the DSEK group (521 ± 39 versus 588 ± 59 µm; p < 0.001), whereas the rebubbling rate was significantly higher in the DSEK group (47.6% versus 18.9%; p = 0.001). Finally, three grafts in the DSEK group experienced failure compared to one graft in the DSAEK group (14% versus 1.9%, respectively). CONCLUSION: Manually dissected and microkeratome-dissected grafts performed similarly with respect to vision and endothelial cell loss assessed one year after surgery. The higher incidence of graft failure among manually dissected (i.e. DSEK) grafts may be attributable to reduced relative thickness compared to DSAEK grafts and/or the resulting differences in tissue handling and the surgeon's learning curve.


Asunto(s)
Enfermedades de la Córnea/cirugía , Queratoplastia Endotelial de la Lámina Limitante Posterior/métodos , Endotelio Corneal/trasplante , Donantes de Tejidos , Agudeza Visual , Anciano , Bancos de Ojos , Femenino , Estudios de Seguimiento , Supervivencia de Injerto , Humanos , Masculino , Estudios Prospectivos , Factores de Tiempo , Resultado del Tratamiento
10.
Acta Ophthalmol Scand ; 84(2): 188-91, 2006 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-16637834

RESUMEN

PURPOSE: Pigmented lesions of the conjunctiva are often difficult to classify clinically. Exfoliative cytology may be helpful, but reliable data regarding the sensitivity and specificity of this test are currently lacking. We determined the value of exfoliative cytology with regard to pigmented conjunctival lesions. METHODS: A total of 294 smears from 182 patients were screened for malignancy within 6 months of exfoliative cytology. Smears were classified according to the following categories: grade 0 = insufficient material for diagnosis; grade 1 = normal conjunctival cells; grade 2 = melanocytes with mild atypia; grade 3 = melanocytes with moderate atypia, and grade 4 = melanocytes with severe atypia. RESULTS: The sensitivity, specificity, positive predictive value and negative predictive value of exfoliative cytology were 85%, 78%, 59% and 93%, respectively. CONCLUSION: Exfoliative cytology is a fast, easy and non-invasive technique that may be used in the evaluation of patients with a pigmented conjunctival lesion.


Asunto(s)
Enfermedades de la Conjuntiva/patología , Neoplasias de la Conjuntiva/patología , Melanoma/patología , Melanosis/patología , Nevo Pigmentado/patología , Lesiones Precancerosas/patología , Adulto , Enfermedades de la Conjuntiva/clasificación , Neoplasias de la Conjuntiva/clasificación , Reacciones Falso Positivas , Femenino , Humanos , Masculino , Melanoma/clasificación , Melanosis/clasificación , Nevo Pigmentado/clasificación , Lesiones Precancerosas/clasificación , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA