Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Surg Endosc ; 38(5): 2805-2816, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38594365

RESUMEN

BACKGROUND: Indocyanine green fluorescence angiography (ICG-FA) may reduce perfusion-related complications of gastrointestinal anastomosis. Software implementations for quantifying ICG-FA are emerging to overcome a subjective interpretation of the technology. Comparison between quantification algorithms is needed to judge its external validity. This study aimed to measure the agreement for visceral perfusion assessment between two independently developed quantification software implementations. METHODS: This retrospective cohort analysis included standardized ICG-FA video recordings of patients who underwent esophagectomy with gastric conduit reconstruction between August 2020 until February 2022. Recordings were analyzed by two quantification software implementations: AMS and CPH. The quantitative parameter used to measure visceral perfusion was the normalized maximum slope derived from fluorescence time curves. The agreement between AMS and CPH was evaluated in a Bland-Altman analysis. The relation between the intraoperative measurement of perfusion and the incidence of anastomotic leakage was determined for both software implementations. RESULTS: Seventy pre-anastomosis ICG-FA recordings were included in the study. The Bland-Altman analysis indicated a mean relative difference of + 58.2% in the measurement of the normalized maximum slope when comparing the AMS software to CPH. The agreement between AMS and CPH deteriorated as the magnitude of the measured values increased, revealing a proportional (linear) bias (R2 = 0.512, p < 0.001). Neither the AMS nor the CPH measurements of the normalized maximum slope held a significant relationship with the occurrence of anastomotic leakage (median of 0.081 versus 0.074, p = 0.32 and 0.041 vs 0.042, p = 0.51, respectively). CONCLUSION: This is the first study to demonstrate technical differences in software implementations that can lead to discrepancies in ICG-FA quantification in human clinical cases. The possible variation among software-based quantification methods should be considered when interpreting studies that report quantitative ICG-FA parameters and derived thresholds, as there may be a limited external validity.


Asunto(s)
Algoritmos , Fuga Anastomótica , Angiografía con Fluoresceína , Verde de Indocianina , Programas Informáticos , Humanos , Estudios Retrospectivos , Angiografía con Fluoresceína/métodos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Fuga Anastomótica/etiología , Fuga Anastomótica/diagnóstico , Fuga Anastomótica/diagnóstico por imagen , Esofagectomía/efectos adversos , Anastomosis Quirúrgica/métodos , Colorantes , Vísceras/irrigación sanguínea
2.
Surg Endosc ; 37(8): 6343-6352, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37208482

RESUMEN

BACKGROUND: Intraoperative perfusion assessment with indocyanine green fluorescence angiography (ICG-FA) may reduce postoperative anastomotic leakage rates after esophagectomy with gastric conduit reconstruction. This study evaluated quantitative parameters derived from fluorescence time curves to determine a threshold for adequate perfusion and predict postoperative anastomotic complications. METHODS: This prospective cohort study included consecutive patients who underwent FA-guided esophagectomy with gastric conduit reconstruction between August 2020 and February 2022. After intravenous bolus injection of 0.05-mg/kg ICG, fluorescence intensity was registered over time by PINPOINT camera (Stryker, USA). Fluorescent angiograms were quantitatively analyzed at a region of interest of 1 cm diameter at the anastomotic site on the conduit using tailor-made software. Extracted fluorescence parameters were both inflow (T0, Tmax, Fmax, slope, Time-to-peak) as outflow parameters (T90% and T80%). Anastomotic complications including anastomotic leakage (AL) and strictures were documented. Fluorescence parameters in patients with AL were compared to those without AL. RESULTS: One hundred and three patients (81 male, 65.7 ± 9.9 years) were included, the majority of whom (88%) underwent an Ivor Lewis procedure. AL occurred in 19% of patients (n = 20/103). Both time to peak as Tmax were significantly longer for the AL group in comparison to the non-AL group (39 s vs. 26 s, p = 0.04 and 65 vs. 51 s, p = 0.03, respectively). Slope was 1.0 (IQR 0.3-2.5) and 1.7 (IQR 1.0-3.0) for the AL and non-AL group (p = 0.11). Outflow was longer in the AL group, although not significantly, T90% 30 versus 15 s, respectively, p = 0.20). Univariate analysis indicated that Tmax might be predictive for AL, although not reaching significance (p = 0.10, area under the curve 0.71) and a cut-off value of 97 s was derived, with a specificity of 92%. CONCLUSION: This study demonstrated quantitative parameters and identified a fluorescent threshold which could be used for intraoperative decision-making and to identify high-risk patients for anastomotic leakage during esophagectomy with gastric conduit reconstruction. A significant predictive value remains to be determined in future studies.


Asunto(s)
Fuga Anastomótica , Esofagectomía , Humanos , Masculino , Fuga Anastomótica/etiología , Fuga Anastomótica/prevención & control , Fuga Anastomótica/cirugía , Esofagectomía/métodos , Estudios Prospectivos , Verde de Indocianina , Estómago/cirugía , Anastomosis Quirúrgica/efectos adversos , Anastomosis Quirúrgica/métodos , Colorantes , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/cirugía , Angiografía con Fluoresceína/métodos , Perfusión
3.
Surg Endosc ; 37(7): 5086-5093, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-36917344

RESUMEN

BACKGROUND: Intraoperative indocyanine green fluorescence angiography (ICG-FA) may be of added value during pouch surgery, in particular after vascular ligations as lengthening maneuver. The aim was to determine quantitative perfusion parameters within the efferent/afferent loop and explore the impact of vascular ligation. Perfusion parameters were also compared in patients with and without anastomotic leakage (AL). METHODS: All consenting patients that underwent FA-guided ileal pouch-anal anastomosis (IPAA) between July 2020 and December 2021 were included. After intravenous bolus injection of 0.1 mg/kg ICG, the near-infrared camera (Stryker Aim 1688) registered the fluorescence intensity over time. Quantitative analysis of ICG-FA from standardized regions of interests on the pouch was performed using software. Fluorescence parameters were extracted for inflow (T0, Tmax, Fmax, slope, Time-to-peak) and outflow (T90% and T80%). Change of management related to FA findings and AL rates were recorded. RESULTS: Twenty-one patients were included, three patients (14%) required vascular ligation to obtain additional length, by ligating terminal ileal branches in two and the ileocolic artery (ICA) in one patient. In nine patients the ICA was already ligated during subtotal colectomy. ICG-FA triggered a change of management in 19% of patients (n = 4/21), all of them had impaired vascular supply (ligated ileocolic/ terminal ileal branches). Overall, patients with intact vascular supply had similar perfusion patterns for the afferent and efferent loop. Pouches with ICA ligation had longer Tmax in both afferent as efferent loop than pouches with intact ICA (afferent 51 and efferent 53 versus 41 and 43 s respectively). Mean slope of the efferent loop diminished in ICA ligated patients 1.5(IQR 0.8-4.4) versus 2.2 (1.3-3.6) in ICA intact patients. CONCLUSION: Quantitative analysis of ICG-FA perfusion during IPAA is feasible and reflects the ligation of the supplying vessels.


Asunto(s)
Proctocolectomía Restauradora , Humanos , Anastomosis Quirúrgica , Fluorescencia , Colectomía , Fuga Anastomótica/etiología , Verde de Indocianina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA