Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
Spine (Phila Pa 1976) ; 22(10): 1160-4, 1997 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-9160477

RESUMEN

STUDY DESIGN: Frameless stereotaxy with doppler ultrasound and three dimensional computer model registration is assessed in vitro for pedicle screw placement. OBJECTIVE: To identify feasibility of pedicle screw navigation and placement using this technology. SUMMARY OF BACKGROUND DATA: Inaccurate pedicle screw placement can lead to neurovascular injury or suboptimal fixation. Present techniques in pedicle screw placement involve only confirmation of hole orientation. METHOD: Forty-four pedicle screws were placed in lumbosacral models and cadaver specimens. Accuracy was assessed with a computed tomography scan and vertebral cross sectioning. RESULTS: All screws were intrapedicular. Accuracy of anterior cortical fixation was 1.5 mm, with a range of 2.5 mm. CONCLUSION: In vitro frameless stereotaxy is accurate for pedicle screw placement. This technology adds a component of navigation to pedicle screw placement.


Asunto(s)
Tornillos Óseos , Vértebras Lumbares/cirugía , Sacro/cirugía , Técnicas Estereotáxicas , Cadáver , Simulación por Computador , Estudios de Factibilidad , Humanos , Procesamiento de Imagen Asistido por Computador , Tomografía Computarizada por Rayos X
2.
J Spinal Disord ; 13(3): 225-9, 2000 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-10872760

RESUMEN

Near-real-time frameless stereotaxy registering intraoperative anatomy to a preoperative three-dimensional computer model has been developed for use with in vivo pedicle screw placement. Eight patients underwent thoracolumbar and lumbar spine stabilization surgery using this new technology, and 32 pedicle screws were placed. Three additional patients had 12 pedicle screws removed during revision surgery, and they allowed the authors to estimate the accuracy of this navigational system. Accuracy was determined by comparing pedicle screw position on postoperative computed tomographs for the first eight patients and on preoperative computed tomographs for the latter three patients, with the intraoperative computer trajectory data gathered during operation. In the group of eight patients, all screws were intrapedicular. In evaluating all 11 patients, the overall accuracy was +/- 2 mm, but the greatest error of 5.4 mm was noted in the sagittal plane measurement. During the development phase of this technology, time constraints prolong surgery, but this may be addressed once the tool's accuracy has been confirmed and intraoperative radiographic confirmation becomes unnecessary. In vivo real-time frameless stereotaxy for pedicle screw placement offers promise for the future. Refinements are needed to improve accuracy and address time constraints.


Asunto(s)
Tornillos Óseos , Procesamiento de Imagen Asistido por Computador/métodos , Fusión Vertebral , Técnicas Estereotáxicas/normas , Interfaz Usuario-Computador , Humanos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA