Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur J Nucl Med Mol Imaging ; 50(12): 3609-3618, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37391545

RESUMEN

PURPOSE: Whether myocardial inflammation causes long-term sequelae potentially affecting myocardial blood flow (MBF) is unknown. We aimed to assess the effect of myocardial inflammation on quantitative MBF parameters, as assessed by 13N-ammonia positron emission tomography myocardial perfusion imaging (PET-MPI) late after myocarditis. METHODS: Fifty patients with a history of myocarditis underwent cardiac magnetic resonance (CMR) imaging at diagnosis and PET/MR imaging at follow-up at least 6 months later. Segmental MBF, myocardial flow reserve (MFR), and 13N-ammonia washout were obtained from PET, and segments with reduced 13N-ammonia retention, resembling scar, were recorded. Based on CMR, segments were classified as remote (n = 469), healed (inflammation at baseline but no late gadolinium enhancement [LGE] at follow-up, n = 118), and scarred (LGE at follow-up, n = 72). Additionally, apparently healed segments but with scar at PET were classified as PET discordant (n = 18). RESULTS: Compared to remote segments, healed segments showed higher stress MBF (2.71 mL*min-1*g-1 [IQR 2.18-3.08] vs. 2.20 mL*min-1*g-1 [1.75-2.68], p < 0.0001), MFR (3.78 [2.83-4.79] vs. 3.36 [2.60-4.03], p < 0.0001), and washout (rest 0.24/min [0.18-0.31] and stress 0.53/min [0.40-0.67] vs. 0.22/min [0.16-0.27] and 0.46/min [0.32-0.63], p = 0.010 and p = 0.021, respectively). While PET discordant segments did not differ from healed segments regarding MBF and MFR, washout was higher by ~ 30% (p < 0.014). Finally, 10 (20%) patients were diagnosed by PET-MPI as presenting with a myocardial scar but without a corresponding LGE. CONCLUSION: In patients with a history of myocarditis, quantitative measurements of myocardial perfusion as obtained from PET-MPI remain altered in areas initially affected by inflammation. CMR = cardiac magnetic resonance; PET = positron emission tomography; LGE = late gadolinium enhancement.


Asunto(s)
Enfermedad de la Arteria Coronaria , Imagen de Perfusión Miocárdica , Miocarditis , Humanos , Radioisótopos de Nitrógeno , Circulación Coronaria/fisiología , Miocarditis/diagnóstico por imagen , Amoníaco , Cicatriz/diagnóstico por imagen , Medios de Contraste , Gadolinio , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Radiofármacos , Inflamación/diagnóstico por imagen , Perfusión , Imagen de Perfusión Miocárdica/métodos
2.
J Nucl Cardiol ; 30(2): 616-625, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-35819716

RESUMEN

BACKGROUND: Positron emission tomography (PET) myocardial perfusion imaging (MPI) can be used to evaluate left ventricular (LV) volumes and function. We performed a head-to-head comparison of LV function and volumes obtained simultaneously using [13N]-ammonia-PET and cardiac magnetic resonance (CMR), with the latter serving as the reference standard. METHODS AND RESULTS: In this prospective study, 51 patients underwent [13N]-ammonia-PET MPI and CMR using a hybrid PET/MR device. Left ventricular end-systolic volumes (LVESV), end-diastolic volumes (LVEDV), stroke volumes (LVSV), ejection fractions (LVEF), and segmental wall motion were analyzed for both methods and were compared using correlational and Bland-Altman (BA) analysis; segmental wall motion was compared using ANOVA. The agreement between [13N]-ammonia-PET and CMR for LVEF was good, with minimal bias (- .6%) and narrow BA limits of agreement (- 7.9% to 6.8%), but [13N]-ammonia-PET systematically underestimated LV volumes, with high bias in LVESV (- 11.2 ml), LVEDV (- 28.9 ml), and LVSV (- 17.5 ml). Mean segmental wall motion in [13N]-ammonia-PET differed significantly among the corresponding normokinetic (6.6 ± 2 mm), hypokinetic (5.1 ± 2 mm), and akinetic (3.3 ± 2 mm) segments in CMR (P < .01). CONCLUSION: LVEF and LV wall motion can be accurately assessed using [13N]-ammonia-PET MPI, although LV volumes are significantly underestimated compared to CMR.


Asunto(s)
Enfermedad de la Arteria Coronaria , Disfunción Ventricular Izquierda , Humanos , Función Ventricular Izquierda , Estudios Prospectivos , Amoníaco , Tomografía Computarizada por Rayos X , Tomografía de Emisión de Positrones/métodos , Volumen Sistólico , Espectroscopía de Resonancia Magnética , Perfusión
3.
J Nucl Cardiol ; 29(1): 350-358, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32613474

RESUMEN

BACKGROUND: Coronary computed tomography angiography (CCTA)-based transluminal attenuation gradient (TAG) was suggested to determine the functional significance of a stenosis. However, evidence that TAG acquired by wide-volume scanners can assess the hemodynamic significance of stenosis assessed by single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is lacking. Moreover, coronary cross-sectional area may influence TAG. Hence, we aimed at assessing the diagnostic value of TAG to predict ischemia in SPECT-MPI and the correlation between TAG and the transluminal cross-sectional area gradient (TCG). METHODS: Patients undergoing CCTA and SPECT-MPI for suspected coronary artery disease were included. TAG and TCG were calculated measuring the mean vessel attenuation and the cross-sectional area along major coronary vessels at 5-mm intervals. RESULTS: A total of 255 coronary arteries of 87 patients were included. TAG and TCG did not discriminate between coronary arteries with or without ischemia as assessed by SPECT-MPI (p = .44 and p = .25, respectively). The area under the curve to predict ischemia was not increased by adding TAG (0.88, 95% CI 0.83-0.92) or TCG (0.87, 95% CI 0.81-0.90) to CCTA alone (0.85, 95% CI 0.80-0.89). There was a significant correlation between TAG and TCG (r = 0.43; p < .001). CONCLUSIONS: CCTA-derived TAG and TCG do not offer any value in predicting ischemia assessed by SPECT-MPI. TAG is partly affected by differences in the coronary luminal area.


Asunto(s)
Angiografía por Tomografía Computarizada , Estenosis Coronaria , Angiografía por Tomografía Computarizada/métodos , Constricción Patológica , Humanos , Isquemia , Perfusión , Tomografía Computarizada de Emisión de Fotón Único
4.
J Nucl Cardiol ; 29(3): 1205-1214, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-33354759

RESUMEN

BACKGROUND: No methodology is available to distinguish truly reduced myocardial flow reserve (MFR) in positron emission tomography myocardial perfusion imaging (PET MPI) from seemingly impaired MFR due to inadequate adenosine response. The adenosine-induced splenic switch-off (SSO) sign has been proposed as a potential marker for adequate adenosine response in cardiac magnetic resonance (CMR). We assessed the feasibility of detecting SSO in nitrogen-13 ammonia PET MPI using SSO in CMR as the standard of reference. METHODS AND RESULTS: Fifty patients underwent simultaneous CMR and PET MPI on a hybrid PET/MR device with co-injection of a gadolinium-based contrast agent and nitrogen-13 ammonia during rest and adenosine-induced stress. In CMR, SSO was assessed visually (positive vs negative SSO) and quantitatively by calculating the ratio of the peak signal intensity of the spleen during stress over rest (SIR). In PET MPI, the splenic signal activity ratio (SAR) was calculated as the maximal standard uptake value of the spleen during stress over rest. The median SIR was significantly lower in patients with positive versus negative SSO in CMR (0.57 [IQR 0.49 to 0.62] vs 0.89 [IQR 0.76 to 0.98]; P < .001). Similarly, median SAR in PET MPI was significantly lower in patients with positive versus negative SSO (0.40 [IQR 0.32 to 0.45] vs 0.80 [IQR 0.47 to 0.98]; P < .001). CONCLUSION: Similarly to CMR, SSO can be detected in nitrogen-13 ammonia PET MPI. This might help distinguish adenosine non-responders from patients with truly impaired MFR due to microvascular dysfunction or multivessel coronary artery disease.


Asunto(s)
Enfermedad de la Arteria Coronaria , Imagen de Perfusión Miocárdica , Adenosina/farmacología , Amoníaco , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Circulación Coronaria , Humanos , Espectroscopía de Resonancia Magnética , Imagen de Perfusión Miocárdica/métodos , Radioisótopos de Nitrógeno , Perfusión , Bazo
5.
Eur J Nucl Med Mol Imaging ; 48(2): 406-413, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-32681446

RESUMEN

PURPOSE: Misalignment between positron emission tomography (PET) datasets and attenuation correction (AC) maps is a potential source of artifacts in myocardial perfusion imaging (MPI). We assessed the impact of adenosine on the alignment of AC maps derived from magnetic resonance (MR) and PET datasets during MPI on a hybrid PET/MR scanner. METHODS: Twenty-eight volunteers underwent adenosine stress and rest 13N-ammonia MPI on a PET/MR. We acquired Dixon sequences for the creation of MRAC maps. After reconstruction of the original non-shifted PET images, we examined MRAC and PET datasets for cardiac spatial misalignment and, if necessary, reconstructed a second set of shifted PET images after manually adjusting co-registration. Summed rest, stress, and difference scores (SRS, SSS, and SDS) were compared between shifted and non-shifted PET images. Additionally, we measured the amount of cranial movement of the heart (i.e., myocardial creep) after termination of adenosine infusion. RESULTS: Realignment was necessary for 25 (89.3%) stress and 12 (42.9%) rest PET datasets. Median SRS, SSS, and SDS of the non-shifted images were 6 (IQR = 4-7), 12 (IQR = 7-18), and 8 (IQR = 2-11), respectively, and of the shifted images 2 (IQR = 1-6), 4 (IQR = 7-18), and 1 (IQR = 0-2), respectively. All three scores were significantly higher in non-shifted versus shifted images (all p < 0.05). The difference in SDS correlated moderately but significantly with the amount of myocardial creep (r = 0.541, p = 0.005). CONCLUSION: Misalignment of MRAC and PET datasets commonly occurs during adenosine stress MPI on a hybrid PET/MR device, potentially leading to an increase in false-positive findings. Our results suggest that myocardial creep may substantially account for this and prompt for a careful review and correction of PET/MRAC data.


Asunto(s)
Imagen de Perfusión Miocárdica , Radioisótopos de Nitrógeno , Artefactos , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones
6.
Eur J Nucl Med Mol Imaging ; 49(1): 311-320, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34191100

RESUMEN

PURPOSE: To assess the prognostic value of regional quantitative myocardial flow measures as assessed by 13N-ammonia positron emission tomography (PET) myocardial perfusion imaging (MPI) in patients with suspected coronary artery disease (CAD). METHODS: We retrospectively included 150 consecutive patients with suspected CAD who underwent clinically indicated 13 N-ammonia PET-MPI and who did not undergo revascularization within 90 days of PET-MPI. The presence or absence of a decreased global myocardial flow reserve (i.e., MFR < 2) as well as decreased regional MFR (i.e., ≥ 2 adjacent segments with MFR < 2) was recorded, and patients were classified as having preserved global and regional MFR (MFR group 1), preserved global but decreased regional MFR (MFR group 2), or decreased global and regional MFR (MFR group 3). We obtained follow-up regarding major adverse cardiac events (MACE, i.e., a combined endpoint including all-cause death, non-fatal myocardial infarction, and late revascularization) and all-cause death. RESULTS: Over a median follow-up of 50 months (IQR 38-103), 30 events occurred in 29 patients. Kaplan-Meier analysis showed significantly reduced event-free and overall survival in MFR groups 2 and 3 compared to MFR group 1 (log-rank: p = 0.015 and p = 0.013). In a multivariable Cox regression analysis, decreased regional MFR was an independent predictor for MACE (adjusted HR 3.44, 95% CI 1.17-10.11, p = 0.024) and all-cause death (adjusted HR 4.72, 95% CI 1.07-20.7, p = 0.04). CONCLUSIONS: A decreased regional MFR as assessed by 13 N-ammonia PET-MPI confers prognostic value by identifying patients at increased risk for future adverse cardiac outcomes and all-cause death.


Asunto(s)
Enfermedad de la Arteria Coronaria , Imagen de Perfusión Miocárdica , Amoníaco , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Humanos , Tomografía de Emisión de Positrones , Pronóstico , Estudios Retrospectivos
7.
Eur Radiol ; 31(7): 5116-5126, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33454800

RESUMEN

OBJECTIVES: Coronary artery volume indexed to left myocardial mass (CAVi), derived from coronary computed tomography angiography (CCTA), has been proposed as an indicator of diffuse atherosclerosis. We investigated the association of CAVi with quantitative flow parameters and its ability to predict ischemia as derived from 13N-ammonia positron emission tomography myocardial perfusion imaging (PET-MPI). METHODS: Sixty patients who underwent hybrid CCTA/PET-MPI due to suspected CAD were retrospectively included. CAVi was defined as total coronary artery lumen volume over myocardial mass, both derived from CCTA. From PET-MPI, quantitative stress and rest myocardial blood flow (MBF) and myocardial flow reserve (MFR) were obtained and correlated with CAVi, and semi-quantitative perfusion images were analyzed for the presence of ischemia. Harrell's c-statistic and net reclassification improvement (NRI) analysis were performed to evaluate the incremental value of CAVi over the CCTA model (i.e., stenosis > 50% and > 70%). RESULTS: CAVi correlated moderately with stress MBF and MFR (R = 0.50, p < 0.001, and R = 0.39, p = 0.002). Mean stress MBF and MFR were lower in patients with low (i.e., ≤ 20.2 mm3/g, n = 24) versus high (i.e., > 20.2 mm3/g, n = 36) CAVi (p < 0.001 for both comparisons). CAVi was independently associated with abnormal stress MBF (OR 0.90, 95% CI 0.82-0.998, p = 0.045). CAVi increased the predictive ability of the CCTA model for abnormal stress MBF and ischemia (c-statistic 0.763 versus 0.596, pdiff < 0.05 and 0.770 versus 0.645, pdiff < 0.05, NRI 0.84, p = 0.001 and 0.96, p < 0.001, respectively). CONCLUSIONS: CAVi exhibits incremental value to predict both abnormal stress MBF and ischemia over CCTA alone. KEY POINTS: • Coronary artery volume indexed to left myocardial mass (CAVi), derived from coronary computed tomography angiography (CCTA), is correlated with myocardial blood flow indices derived from 13N-ammonia positron emission tomography myocardial perfusion imaging. • CAVi is independently associated with abnormal stress myocardial blood flow. • CAVi provides incremental diagnostic value over CCTA for both abnormal stress MBF and ischemia.


Asunto(s)
Aterosclerosis , Enfermedad de la Arteria Coronaria , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica , Amoníaco , Animales , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Cobayas , Humanos , Tomografía de Emisión de Positrones , Valor Predictivo de las Pruebas , Estudios Retrospectivos
8.
J Cardiovasc Magn Reson ; 23(1): 3, 2021 01 07.
Artículo en Inglés | MEDLINE | ID: mdl-33407586

RESUMEN

BACKGROUND: Inadequate coronary adenosine response is a potential cause for false negative ischemia testing. Recently, the splenic switch-off (SSO) sign has been identified as a promising tool to ascertain the efficacy of adenosine during vasodilator stress cardiovascular magnetic resonance imaging (CMR). We assessed the value of SSO to predict adenosine response, defined as an increase in myocardial blood flow (MBF) during quantitative stress myocardial perfusion 13 N-ammonia positron emission tomography (PET). METHODS: We prospectively enrolled 64 patients who underwent simultaneous CMR and PET myocardial perfusion imaging on a hybrid PET/CMR scanner with co-injection of gadolinium based contrast agent (GBCA) and 13N-ammonia during rest and adenosine-induced stress. A myocardial flow reserve (MFR) of  > 1.5 or ischemia as assessed by PET were defined as markers for adequate coronary adenosine response. The presence or absence of SSO was visually assessed. The stress-to-rest intensity ratio (SIR) was calculated as the ratio of stress over rest peak signal intensity for splenic tissue. Additionally, the spleen-to-myocardium ratio, defined as the relative change of spleen to myocardial signal, was calculated for stress (SMRstress) and rest. RESULTS: Sixty-one (95%) patients were coronary adenosine responders, but SSO was absent in 18 (28%) patients. SIR and SMRstress were significantly lower in patients with SSO (SIR: 0.56 ± 0.13 vs. 0.93 ± 0.23; p < 0.001 and SMRstress: 1.09 ± 0.47 vs. 1.68 ± 0.62; p < 0.001). Mean hyperemic and rest MBF were 2.12 ± 0.68 ml/min/g and 0.78 ± 0.26 ml/min/g, respectively. MFR was significantly higher in patients with vs. patients without presence of SSO (3.07 ± 1.03 vs. 2.48 ± 0.96; p = 0.038), but there was only a weak inverse correlation between SMRstress and MFR (R = -0.378; p = 0.02) as well as between SIR and MFR (R = -0.356; p = 0.004). CONCLUSIONS: The presence of SSO implies adequate coronary adenosine-induced MBF response. Its absence, however, is not a reliable indicator for failed adenosine-induced coronary vasodilatation.


Asunto(s)
Adenosina/administración & dosificación , Amoníaco , Circulación Coronaria , Imagen por Resonancia Magnética , Isquemia Miocárdica/diagnóstico por imagen , Imagen de Perfusión Miocárdica , Radioisótopos de Nitrógeno , Tomografía de Emisión de Positrones , Bazo/irrigación sanguínea , Vasodilatadores/administración & dosificación , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Isquemia Miocárdica/fisiopatología , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados
9.
J Nucl Cardiol ; 28(1): 263-273, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-30895563

RESUMEN

OBJECTIVE: Positron emission tomography (PET) integrating assessment of perfusion with 13N-ammonia (NH3) and viability with 18F-fluorodeoxyglucose (FDG) has high accuracy to identify viable, hibernating myocardium. We tested whether quantification of myocardial blood flow (MBF) and washout (k2) can predict myocardial viability using FDG as standard of reference. METHODS: In 180 consecutive patients with ischemic cardiomyopathy, myocardium was categorized on a segment-level into normal, ischemic, hibernating, and scar. From dynamic images, stress MBF, rest MBF, and k2 were derived and myocardial flow reserve (MFR) and volume of distribution (VD) were calculated. RESULTS: Across myocardial tissues, all parameters differed significantly. The area under the curve (AUC) was 0.564 (95% CI 0.527-0.601), 0.635 (0.599-0.671), 0.553 (0.516-0.591), 0.520 (0.482-0.559), and 0.560 (0.522-0.597) for stress MBF, rest MBF, MFR, k2, and VD. The generalized linear mixed model correctly classified 81% of scar as viable, hibernating myocardium. If the threshold of rest MBF to predict viability was set to 0.45 mL·min-1·g-1, sensitivity and specificity were 96% and 12%, respectively. CONCLUSION: Quantitative NH3 PET parameters have low to moderate diagnostic performance to predict viability in ischemic cardiomyopathy. However, if rest MBF falls below 0.45 mL·min-1·g-1, viability testing by FDG-PET may be safely deferred.


Asunto(s)
Amoníaco/farmacocinética , Circulación Coronaria/fisiología , Isquemia Miocárdica/diagnóstico por imagen , Radioisótopos de Nitrógeno/farmacocinética , Tomografía de Emisión de Positrones , Anciano , Femenino , Fluorodesoxiglucosa F18/farmacocinética , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/metabolismo , Imagen de Perfusión Miocárdica , Valor Predictivo de las Pruebas , Curva ROC , Radiofármacos/farmacocinética , Estudios Retrospectivos
10.
J Nucl Cardiol ; 27(3): 726-736, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31286420

RESUMEN

BACKGROUND: Sexual dimorphism in the manifestation of coronary artery disease (CAD) has unleashed a call to reconsider cardiovascular risk assessment. Alterations of bone mineral density (BMD) have been associated with congestive heart failure and appear to be modified by sex. However, the sex-specific association between BMD, myocardial perfusion, and cardiovascular outcomes is currently unknown. METHODS: A total number of 491 patients (65.9 ± 10.7 years, 32.4% women) underwent 13N-ammonia positron emission tomography/computed tomography for evaluation of CAD, and were tracked for major adverse cardiac events (MACEs). RESULTS: Event-free survival (median follow-up time of 4.3 ± 2.0 years) was significantly reduced in patients with low (≤ 100 Hounsfield units) compared to those with higher BMD (log-rank P = .037). Accordingly, reduced BMD was chosen as significant predictor of MACE in a fully adjusted proportional hazards regression model (P = .015). Further, a first-order interaction term consisting of sex and BMD was statistically significant (P = .007). BMD was significantly lower in patients with abnormal myocardial perfusion or impaired left ventricular ejection fraction (P < .05). This difference, however, was noticed in men, but not in women. CONCLUSIONS: The association between low BMD and cardiovascular disease is sex dependent. Our data suggest that quantification of BMD during myocardial perfusion imaging for evaluation of CAD may be particularly useful in men.


Asunto(s)
Densidad Ósea , Enfermedades Cardiovasculares/diagnóstico por imagen , Enfermedades Cardiovasculares/terapia , Corazón/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Anciano , Amoníaco , Supervivencia sin Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radioisótopos de Nitrógeno , Tomografía Computarizada por Tomografía de Emisión de Positrones , Estudios Retrospectivos , Riesgo , Factores de Riesgo , Factores Sexuales , Vértebras Torácicas/diagnóstico por imagen , Resultado del Tratamiento
11.
J Nucl Cardiol ; 27(1): 159-170, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-29687292

RESUMEN

BACKGROUND: In light of growing cardiovascular mortality rates observed in young women, sexual dimorphism in cardiac autonomic nervous control is gaining increasing attention. Heart rate responses to adenosine mirror autonomic activity and may carry important prognostic information. METHODS AND RESULTS: Hemodynamic changes during adenosine stress were retrospectively analysed in a propensity-matched cohort of 1932 consecutive patients undergoing myocardial perfusion single-photon-emission computed tomography (MPI-SPECT). Heart rate (HR) and systolic blood pressure (SBP) increased during adenosine infusion (P < 0.001). The increase in SBP and HR (heart rate reserve, HRR), was significantly more pronounced in women compared with men (P < 0.05). Patients ≤ 55 years had a higher HRR compared with patients > 55 years (46.8% vs 37.5%, P = 0.015). Women ≤ 55 years with a reversible perfusion defect on MPI-SPECT exhibited the highest HRR (89.2%), while age-matched men showed a blunted HR response to adenosine (26.4%, P = 0.01). Accordingly, age and an interaction term of female sex and increased HRR were identified as significant predictors of myocardial ischemia in a multiple regression analysis (OR 1.4, 95% CI 1.02-1.9, P = 0.038). CONCLUSION: HRR during adenosine infusion is influenced by age and sex. Our data suggest a stronger, sympathetic-driven, hemodynamic response to adenosine in younger women with myocardial ischemia.


Asunto(s)
Adenosina/farmacología , Frecuencia Cardíaca/efectos de los fármacos , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/fisiopatología , Imagen de Perfusión Miocárdica , Tomografía Computarizada de Emisión de Fotón Único , Factores de Edad , Anciano , Anciano de 80 o más Años , Presión Sanguínea/fisiología , Prueba de Esfuerzo , Femenino , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Estudios Retrospectivos , Factores Sexuales , Vasodilatadores/farmacología
12.
J Comput Assist Tomogr ; 44(2): 289-294, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32195809

RESUMEN

OBJECTIVE: The purpose of this study was to quantify the reduction in radiation dose achievable by using the optimal z-axis coverage in coronary computed tomography (CT) angiography (CCTA) on a latest-generation 256-slice scanner. METHODS: A total of 408 scans were reviewed that were performed on a wide-range detector scanner allowing up to 16-cm z-axis coverage (adjustable in 2-cm increments). For each CCTA study, we assessed the radiation dose (ie, dose-length product and volume CT dose index) and measured the minimum z-axis coverage necessary to cover the complete cardiac anatomy. We calculated the potential radiation dose savings achievable through reduction of the z-axis coverage to the minimum necessary. RESULTS: The majority of the CCTA scans were performed with a z-axis coverage of 16 cm (n = 285, 69.9%), followed by 14 cm (n = 121, 29.7%) and 12 cm (n = 2, 0.5%). In the group that was scanned with a collimation of 16 cm, radiation dose could have been reduced by 12.5% in 55 patients, 25% in 195 patients, and 37.5% in 33 patients when using optimal z-axis coverage for CCTA. In the group that was scanned with a collimation of 14 cm, radiation dose could have been reduced by 14.3% in 90 patients, and 28.6% in 30 patients, whereas in the group that was scanned with a collimation of 12 cm, dose could have been reduced by 16.7% in 2 patients. CONCLUSIONS: Using correct z-axis coverage in CCTA on a latest-generation 256-slice scanner yields average dose reductions of 22.0% but may be as high as 37.5%.


Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Dosis de Radiación , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos
13.
Eur J Nucl Med Mol Imaging ; 46(11): 2322-2328, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31359109

RESUMEN

PURPOSE: The human pathophysiology of stunned, hibernating and scarred myocardium in ischemic cardiomyopathy is a subject of controversy. While the "smart heart" theory postulates that reduced myocardial blood flow (MBF) at rest is responsible for myocytes switching to a state of hibernation, other theories suggest that a reduced myocardial flow reserve (MFR) may be the cause. METHODS: We included 110 patients with ischemic cardiomyopathy. Based on quantitative myocardial perfusion assessment and viability imaging with 13N-NH3 and 18F-FDG positron emission tomography, respectively, as well as wall motion assessment from echocardiography, myocardial tissue was characterized as remote (i.e., normal myocardium), stunned (i.e., dysfunctional but viable myocardium with normal rest perfusion), hibernating (i.e., dysfunctional but viable myocardium with impaired rest perfusion), or scarred myocardium (i.e., non-viable myocardium). RESULTS: Compared to remote myocardium, dysfunctional but viable myocardium (including stunned and hibernating) had reduced rest MBF (0.89 mL/min/g vs. 0.79 and 0.76 mL/min/g, respectively; p < 0.001) and MFR (1.53 vs. 1.27 and 1.17; p < 0.001). Between stunned and hibernating myocardium, however, rest MBF and MFR did not differ (p = 0.40). In scarred myocardium, rest MBF was lowest (0.66 mL/min/g; p < 0.001) but, in contrast to the other myocardial states, k2 (i.e., tracer washout) was increased (0.199/min vs. 0.178/min to 0.181/min; all p < 0.05 in pairwise comparison). CONCLUSIONS: In patients with ischemic cardiomyopathy, impaired MFR is associated with stunning and hibernation. These states of dysfunctional but viable myocardium have lower rest MBF compared to remote myocardium. At the end of the continuum, rest MBF is lowest in scar tissue and linked to increased rate of tracer washout.


Asunto(s)
Corazón/diagnóstico por imagen , Isquemia Miocárdica/diagnóstico por imagen , Miocardio/patología , Anciano , Cardiomiopatías , Femenino , Fluorodesoxiglucosa F18 , Corazón/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Movimiento (Física) , Isquemia Miocárdica/fisiopatología , Imagen de Perfusión Miocárdica , Tomografía de Emisión de Positrones , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Disfunción Ventricular Izquierda
14.
Eur J Nucl Med Mol Imaging ; 46(6): 1257-1267, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30648200

RESUMEN

PURPOSE: Evidence to date has failed to adequately explore determinants of cardiovascular risk in women with coronary microvascular dysfunction (CMVD). Heart rate responses to adenosine mirror autonomic activity and may carry important prognostic information for the diagnosis of CMVD. METHODS: Hemodynamic changes during adenosine stress were analyzed in a propensity-matched cohort of 404 patients (202 women, mean age 65.9 ± 11.0) who underwent clinically indicated myocardial perfusion 13N-ammonia Positron-Emission-Tomography (PET) at our institution between September 2013 and May 2017. RESULTS: Baseline heart rate (HR) was significantly higher in patients with abnormal coronary flow reserve (CFR, p < 0.001 vs normal CFR). Accordingly, a blunted HR response to adenosine (=reduced heart rate reserve, %HRR) was seen in patients with abnormal CFR, with a most pronounced effect being observed in female patients free of myocardial ischemia (45.9 ± 34.9 vs 26.5 ± 18.0, p < 0.001 in women and 29.1 ± 16.9 vs 24.3 ± 21.7, p = 0.15 in men). Hence, a fully-adjusted multivariate logistic regression model identified HRR as the strongest negative predictor of reduced CFR in women free of myocardial ischemia, but not in men. Accordingly, receiver operating characteristics (ROC) curves for the presence of reduced CFR revealed that a %HRR <35 was a powerful predictor for abnormal CFR with a sensitivity of 81% and a specificity of 60% in women. CONCLUSION: A blunted HRR <35% is associated with abnormal CFR in women. Taking into account HR responses during stress test in women may help to risk stratify the heterogeneous female population of patients with non-obstructive coronary artery disease (CAD).


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico , Imagen de Perfusión Miocárdica , Radioisótopos de Nitrógeno , Anciano , Área Bajo la Curva , Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria , Prueba de Esfuerzo , Femenino , Frecuencia Cardíaca , Hemodinámica , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Análisis Multivariante , Isquemia Miocárdica/fisiopatología , Isótopos de Nitrógeno , Tomografía de Emisión de Positrones , Curva ROC , Radiofármacos , Riesgo , Factores de Riesgo , Sensibilidad y Especificidad , Factores Sexuales
15.
Eur J Nucl Med Mol Imaging ; 46(10): 2032-2041, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31254034

RESUMEN

BACKGROUND: Although women with cardiovascular disease experience relatively worse outcomes as compared to men, substantial knowledge gaps remain regarding the unique female determinants of cardiovascular risk. Heart rate (HR) responses to vasodilator stress mirror autonomic activity and may carry important long-term prognostic information in women. METHODS AND RESULTS: Hemodynamic changes during adenosine stress were recorded in a total of 508 consecutive patients (104 women) undergoing clinically indicated 13N-ammonia Positron-Emission-Tomography (PET) at our institution. Following propensity matching, 202 patients (101 women, mean age 61.3 ± 12.6 years) were analyzed. During a median follow-up of 5.6 years, 97 patients had at least one cardiac event, including 17 cardiac deaths. Heart rate reserve (% HRR) during adenosine infusion was significantly higher in women as compared to men (23.8 ± 19.5 vs 17.3 ± 15.3, p = 0.009). A strong association between 10-year cardiovascular endpoints and a blunted HRR was observed in women, while this association was less pronounced in men. Accordingly, in women, but not in men, reduced HRR was selected as a strong predictor for adverse cardiovascular events in a Cox regression model fully adjusted for imaging findings and traditional risk factors (HR 2.41, 95% CI 1.23-4.75, p = 0.011). Receiver operating characteristics (ROC) curves revealed that a blunted HRR <21% was a powerful predictor for MACE in women with a sensitivity of 77% and a specificity of 68%. CONCLUSION: Blunted HRR to adenosine stress adds incremental prognostic value for long-term cardiovascular outcomes in women beyond that provided by traditional risk factors and imaging findings.


Asunto(s)
Cardiopatías/diagnóstico por imagen , Frecuencia Cardíaca , Imagen de Perfusión Miocárdica/métodos , Tomografía de Emisión de Positrones/métodos , Adenosina/administración & dosificación , Adenosina/farmacología , Anciano , Femenino , Corazón/efectos de los fármacos , Corazón/fisiopatología , Cardiopatías/diagnóstico , Humanos , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/normas , Radioisótopos de Nitrógeno , Radiofármacos , Sensibilidad y Especificidad , Vasodilatadores/administración & dosificación , Vasodilatadores/farmacología
16.
Radiology ; 288(3): 694-702, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29969066

RESUMEN

Purpose To determine the value of cardiac hybrid imaging, performed by combining SPECT myocardial perfusion imaging (MPI) with coronary CT angiography, as a long-term predictor for major adverse cardiac events (MACEs) (death, myocardial infarction [MI], unstable angina requiring hospitalization, coronary revascularization). Materials and Methods For this retrospective single-center study, 428 patients referred between May 2005 and December 2008 were classified according to hybrid imaging findings into the following groups: (a) those with stenosis of 50% or greater (at coronary CT angiography) with ischemia (at SPECT) in subtended territory (matched), (b) those with coronary CT angiography and/or SPECT findings in unrelated territories (unmatched), and (c) those with normal findings at coronary CT angiography and SPECT. End points were all-cause death or MI ("hard events") and a composite of MACEs. The Kaplan-Meier method was used to identify survival free of MACEs, and Cox proportional hazard regression analysis was used to determine independent predictors for MACE. Results During a median follow-up of 6.8 years, a total of 160 MACEs, including 45 deaths, were observed in the final study population (mean age, 62 years ± 11 [standard deviation]; 132 women). The annual hard event rate was more than fivefold higher for patients with matched findings (n = 46 [7.0%]) and was threefold higher for patients with unmatched findings (n = 113 [3.7%]) compared with that for patients with normal findings (1.2%; n = 216 [1.2%]; P < .001). The MACE rates were 21.8%, 9.0%, and 2.4% for matched, unmatched, and normal findings, respectively. A matched finding was an independent predictor for MACE and hard events. Conclusion In patients evaluated for coronary artery disease, cardiac hybrid imaging is an excellent long-term predictor of adverse cardiac events. A matched hybrid finding is associated with a high annual cardiac event rate. © RSNA, 2018.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Evaluación del Resultado de la Atención al Paciente , Tomografía Computarizada de Emisión de Fotón Único/métodos , Adulto , Anciano , Anciano de 80 o más Años , Enfermedades Cardiovasculares/complicaciones , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Imagen Multimodal/métodos , Imagen de Perfusión Miocárdica , Valor Predictivo de las Pruebas , Pronóstico , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo
18.
Angiology ; 75(4): 367-374, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36786297

RESUMEN

Myocardial bridging (MB) is a segment of coronary arteries with an intramural course, typically spared from atherosclerosis, while the adjacent proximal segment is reported to be atherosclerosis-prone, a phenomenon contributed to local endothelial shear stress (ESS). We aimed to describe the ESS milieu in coronaries with MBs combining coronary computed tomography angiography with computational fluid dynamics and to investigate the association of atherosclerosis presence proximal to MBs with hemorheological characteristics. Patients (n = 36) were identified and 36 arteries with MBs (11 deep and 25 superficial) were analyzed. ESS did not fluctuate 5 mm proximally to MBs vs 5 mm within MBs (0.94 vs 1.06 Pa, p = .56). There was no difference when comparing ESS in the proximal versus mid versus distal MB segments (1.48 vs 1.37 vs 1.9 Pa, p = ns). In arteries with plaques (n = 12), no significant ESS variances were observed around the MB entrance, when analyzing all arteries (p = .81) and irrespective of morphological features of the bridged segment (deep MBs; p = .65, superficial MBs; p = .84). MBs are characterized by homogeneous, atheroprotective ESS, possibly explaining the absence of atherosclerosis within bridged segments. The interplay between ESS and atherosclerosis is potentially not different in arteries with MB compared with arteries without bridges.


Asunto(s)
Aterosclerosis , Enfermedad de la Arteria Coronaria , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Angiografía Coronaria/métodos , Corazón , Vasos Coronarios/diagnóstico por imagen
19.
Acad Radiol ; 29 Suppl 4: S11-S16, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-33187851

RESUMEN

OBJECTIVE: To evaluate the impact of adaptive statistical iterative reconstruction-V (ASIR-V) on the accuracy of ultra-low-dose coronary artery calcium (CAC) scoring. MATERIALS AND METHOD: One-hundred-and-three patients who underwent computed tomography (CT) for CAC scoring were prospectively included. All underwent standard scanning with 120-kilovolt-peak (kVp) and with 80- and 70-kVp tube voltage. ASiR-V was applied to the 80- and 70-kVp scans at different levels. The 120-kVp scans reconstructed with filtered back projection served as the standard of reference. Recently published novel kVp-adapted thresholds were used for calculation of CAC scores from 80- and 70-kVp scans and the resulting CAC scores were compared against the standard of reference. Patients were stratified into six CAC score risk categories: 0, 1-10, 11-100, 101-400, 401-1000, and >1000. RESULTS: Increasing levels of ASIR-V led to an increasing underestimation of CAC scores with bias ranging from -128 to -118 and from -205 to -198 for the 80- and 70-kVp scans, respectively, when compared with the standard of reference. Reconstruction with 20% and 40% ASIR-V for the 80- and 70-kVp scans, respectively, yielded noise levels comparable to the standard of reference. Nevertheless, a change in risk-class was observed in 29 (28.6%) and 46 (44.7%) patients, exclusively to a lower risk-class, when CAC scores were derived from these reconstructions. CONCLUSION: ASIR-V leads to noise reduction in CT scans acquired with low tube-voltages. However, ASIR-V introduces substantial inaccuracies and marked underestimation of ultra-low-dose CAC scoring as compared with standard-dose CAC scoring despite normalization of noise.


Asunto(s)
Calcio , Vasos Coronarios , Algoritmos , Vasos Coronarios/diagnóstico por imagen , Humanos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Cintigrafía , Tomografía Computarizada por Rayos X/métodos
20.
Int J Cardiovasc Imaging ; 38(10): 2227-2234, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37726457

RESUMEN

To determine if coronary artery calcium (CAC) scoring using computed tomography at 80 kilovolt-peak (kVp) and 70-kVp and tube voltage-adapted scoring-thresholds allow for accurate risk stratification as compared to the standard 120-kVp protocol. We prospectively included 170 patients who underwent standard CAC scanning at 120-kVp and 200 milliamperes and additional scans with 80-kVp and 70-kVp tube voltage with adapted tube current to normalize image noise across scans. Novel kVp-adapted thresholds were applied to calculate CAC scores from the low-kVp scans and were compared to those from standard 120-kVp scans by assessing risk reclassification rates and agreement using Kendall's rank correlation coefficients (Τb) for risk categories bounded by 0, 1, 100, and 400. Interreader reclassification rates for the 120-kVp scans were assessed. Agreement for risk classification obtained from 80-kVp and 70-kVp scans as compared to 120-kVp was good (Τb = 0.967 and 0.915, respectively; both p < 0.001) with reclassification rates of 7.1% and 17.2%, respectively, mostly towards a lower risk category. By comparison, the interreader reclassification rate was 4.1% (Τb = 0.980, p < 0.001). Reclassification rates were dependent on body mass index (BMI) with 7.1% and 13.6% reclassifications for the 80-kVp and 70-kVp scans, respectively, in patients with a BMI < 30 kg/m2 (n = 140), and 2.9% and 7.4%, respectively, in patients with a BMI < 25 kg/m2 (n = 68). Mean effective radiation dose from the 120-kVp, the 80-kVp, and 70-kVp scans was 0.54 ± 0.03, 0.42 ± 0.02, and 0.26 ± 0.02 millisieverts. CAC scoring with reduced tube voltage allows for accurate risk stratification if kVp-adapted thresholds for calculation of CAC scores are applied.ClinicalTrials.gov NCT03637231.


Asunto(s)
Calcio , Vasos Coronarios , Humanos , Vasos Coronarios/diagnóstico por imagen , Valor Predictivo de las Pruebas , Medición de Riesgo , Tomografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA