Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo de estudio
Tipo del documento
Intervalo de año de publicación
1.
Artif Organs ; 43(9): 880-887, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-30964951

RESUMEN

Chromogenic anti-Xa assays for unfractionated heparin monitoring (heparin activity) are susceptible to interference from hemolysis and icterus. The purpose of this study was to better understand the effect of hemolysis and icterus on anti-Xa heparin activity and to predict the magnitude of the error. Increasing levels of hemoglobin and unconjugated bilirubin were added to pooled normal plasma or buffer containing known levels of heparin. Increased plasma hemoglobin or bilirubin produced falsely increased residual factor Xa activity as measured by the absorbance change (OD/min) in the Stago heparin activity assay. This increased absorbance change slope resulted in falsely lower estimates of heparin activity. The falsely lower heparin activity measurement occurred even when heparin was not present, indicating it was not due to heparin neutralization. In a sample containing 0.62 ± 0.06 U/mL heparin and 228 mg/dL hemoglobin, the measured heparin activity was 0.41 ± 0.03 U/mL, underestimating heparin activity by 0.21 ± 0.07 U/mL. Interference occurred if plasma hemoglobin was above 70 mg/dL or bilirubin was above 16 mg/dL, which happened in 16%-26% of samples from pediatric patients on extracorporeal life support (ECLS). In conclusion, hemolysis and icterus were common in ECLS patients, leading to underestimates of unfractionated heparin activity and potentially higher doses of heparin than intended. The magnitude of the heparin activity measurement error could be predicted based on plasma hemoglobin and bilirubin levels until these levels exceeded the technical limits of the assay, ~230 mg/dL hemoglobin and 55 mg/dL bilirubin.


Asunto(s)
Monitoreo de Drogas/métodos , Oxigenación por Membrana Extracorpórea , Inhibidores del Factor Xa/sangre , Heparina/sangre , Bilirrubina/sangre , Niño , Inhibidores del Factor Xa/uso terapéutico , Hemoglobinas/análisis , Hemólisis/efectos de los fármacos , Heparina/uso terapéutico , Humanos , Ictericia/sangre , Ictericia/terapia
2.
Bioorg Med Chem Lett ; 25(21): 4774-4776, 2015 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-26216842

RESUMEN

Pentapeptides have been shown to bind the synthetic heparin fondaparinux (Arixtra) as well the biological heparins dalteparin (Fragmin) and salmon heparin. In contrast to heparin binding consensus sequences, the pentapeptides are acidic or neutral, with no arginine or histidine residue. The peptides showed an effect on in vitro heparin anti-factor X activity with a reduction of fondaparinux activity by 65-95%. Heparin binding was further studied by using peptide solid phase chromatography and NMR analysis.


Asunto(s)
Heparina/química , Heparina/síntesis química , Oligopéptidos/química , Sitios de Unión , Relación Dosis-Respuesta a Droga , Estructura Molecular , Relación Estructura-Actividad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA