Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Chembiochem ; : e202400395, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39145407

RESUMEN

Broadening of signals from atoms at interfaces can often be a limiting factor in applying solution NMR to the structure determination of complexes. Common contributors to such problems include exchange between free and bound states and the increased molecular weight of complexes relative to the free components, but another cause that can be more difficult to deal with occurs when conformational dynamics within the interface takes place at an intermediate rate on the chemical shift timescale. In this work we show how a carefully chosen mutation in the protein HMG-D rescued such a situation, making possible high-resolution structure determination of its complex with a dA2 bulge DNA ligand designed to mimic a natural DNA bend, and thereby revealing a new spatial organization of the complex.

2.
Nanotechnology ; 2024 Aug 13.
Artículo en Inglés | MEDLINE | ID: mdl-39137800

RESUMEN

Line edge roughness (LER) has been an important issue in the nanofabrication research, especially in integrated circuits. Despite numerous research studies has made efforts on achieving smaller LER value, a strategy to achieve sub-nanometer level LER still remain challenging due to inability to deposit energy with a profile of sub-nanometer LER. In this work, we use scanning helium ion beam to expose hydrogen silsesquioxane (HSQ) resist on SiNx membrane and present the 0.16 nm spatial imaging resolution based on this suspended thin membrane geometric construction, which is characterized by scanning transmission electron microscope (STEM). The suspended membrane serves as an energy filter of helium ion beam and due to the elimination of backscattering induced secondary electrons, we can systematically study the factors that influences the LER of the fabricated nanostructures. Furthermore, we explore the parameters including step size, designed exposure linewidth (DEL), delivered dosage and resist thickness and choosing the high contrast developer, the process window allows to fabricate lines with 0.2nm LER is determined. AFM measurement and simulation work further reveal that at specific beam step size and DEL, the nanostructures with minimum LER can only be fabricated at specific resist thickness and dosage. .

3.
Sensors (Basel) ; 24(11)2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38894446

RESUMEN

Narrow-linewidth lasers mainly depend on the development of advanced laser linewidth measurement methods for related technological progress as key devices in satellite laser communications, precision measurements, ultra-high-speed optical communications, and other fields. This manuscript provides a theoretical analysis of linewidth characterization methods based on the beat frequency power spectrum and laser phase noise calculations, and elaborates on existing research of measurement technologies. In addition, to address the technical challenges of complex measurement systems that commonly rely on long optical fibers and significant phase noise jitter in the existing research, a short-delay self-heterodyne method based on coherent envelope spectrum demodulation was discussed in depth to reduce the phase jitter caused by 1/f noise. We assessed the performance parameters and testing conditions of different lasers, as well as the corresponding linewidth characterization methods, and analyzed the measurement accuracy and error sources of various methods.

4.
Sensors (Basel) ; 24(4)2024 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-38400261

RESUMEN

In the field of inter-satellite laser communication, achieving high-quality communication and compensating for the Doppler frequency shift caused by relative motion necessitate lasers with narrow linewidths, low phase noise, and the ability to achieve mode-hop-free tuning within a specific range. To this end, this paper investigates a novel external cavity diode laser (ECDL) with a frequency-selective F-P etalon structure, leveraging the external cavity F-P etalon structure in conjunction with an auxiliary filter to achieve single longitudinal mode selection. The laser undergoes linewidth testing using a delayed self-heterodyne beating method, followed by the testing of its phase noise and frequency noise characteristics using a noise analyzer, yielding beat spectra and noise power spectral density profiles. Furthermore, the paper introduces an innovative bidirectional temperature-scanning laser method to achieve optimal laser-operating point selection and mode-hop-free tuning. The experimental results showcase that the single longitudinal mode spectral side-mode suppression ratio (SMSR) is around 70 dB, and the output power exceeds 10 mW. Enhancing the precision of the F-P etalon leads to a more pronounced suppression of low-frequency phase noise, reducing the Lorentzian linewidth from the initial 10 kHz level to a remarkable 5 kHz level. The bidirectional temperature-scanning laser method not only allows for the selection of the optimal operating point but also enables mode-hop-free tuning within 160 pm.

5.
Sensors (Basel) ; 24(6)2024 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-38544040

RESUMEN

The Self-Mixing Interformeter (SMI) is a self-aligned optical interferometer which has been used for acoustic wave sensing in air through the acousto-optic effect. This paper presents how to use a SMI for the measurement of Sound Pressure Level (SPL) in acoustic waveguides. To achieve this, the SMI is first calibrated in situ as a vibrometer. The optical feedback parameters C and α in the strong feedback regime (C≥4.6) are estimated from the SMI vibrometric signals and by the solving of non-linear equations governing the SMI behaviour. The calibration method is validated on synthetic SMI signals simulated from SMI governing equations for C ranging from 5 to 20 and α ranging from 4 to 10. Knowing C and α, the SMI is then used as an acoustic pressure sensor. The SPLs obtained using the SMI are compared with a reference microphone, and a maximal deviation of 2.2 dB is obtained for plane waves of amplitudes ranging from 20 to 860 Pa and frequencies from 614 to 17,900 Hz. The SPL measurements are carried out for C values ranging from 7.1 to 21.5.

6.
Micromachines (Basel) ; 15(7)2024 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-39064383

RESUMEN

In this paper, we have demonstrated a narrow linewidth high power fiber laser emitting at a short wavelength of ~1050 nm. The fiber laser is based on a structure of master oscillator power amplification (MOPA) with an optimized fiber Bragg-grating-based laser cavity as the seed. Both stimulated Brillouin scattering (SBS) and stimulated Raman scattering (SRS) effects have been effectively suppressed by using a long passive fiber between the seed and the amplifier. Based on the fiber amplifier, we have ultimately boosted the narrow linewidth laser from ~40 W to 3.2 kW with a slope efficiency of 85.1% and a 3-dB linewidth of ~0.1 nm. The SRS suppression ratio of the laser is ~29.7 dB at maximum power. Due to our fiber mode control strategies, the beam quality always stays near-diffraction-limited while amplifying, and the measured M2 factor is ~1.4 at the maximum power. Further increase in output power is limited by the SBS effect.

7.
bioRxiv ; 2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38464094

RESUMEN

J-difference-edited MRS is widely used to study GABA in the human brain. Editing for low-concentration target molecules (such as GABA) typically exhibits lower signal-to-noise ratio (SNR) than conventional non-edited MRS, varying with acquisition region, volume and duration. Moreover, spectral lineshape may be influenced by age-, pathology-, or brain-region-specific effects of metabolite T2, or by task-related blood-oxygen level dependent (BOLD) changes in functional MRS contexts. Differences in both SNR and lineshape may have systematic effects on concentration estimates derived from spectral modelling. The present study characterises the impact of lineshape and SNR on GABA+ estimates from different modelling algorithms: FSL-MRS, Gannet, LCModel, Osprey, spant and Tarquin. Publicly available multi-site GABA-edited data (222 healthy subjects from 20 sites; conventional MEGA-PRESS editing; TE = 68 ms) were pre-processed with a standardised pipeline, then filtered to apply controlled levels of Lorentzian and Gaussian linebroadening and SNR reduction. Increased Lorentzian linewidth was associated with a 2-5% decrease in GABA+ estimates per Hz, observed consistently (albeit to varying degrees) across datasets and most algorithms. Weaker, often opposing effects were observed for Gaussian linebroadening. Variations are likely caused by differing baseline parametrization and lineshape constraints between models. Effects of linewidth on other metabolites (e.g., Glx and tCr) varied, suggesting that a linewidth confound may persist after scaling to an internal reference. These findings indicate a potentially significant confound for studies where linewidth may differ systematically between groups or experimental conditions, e.g. due to T2 differences between brain regions, age, or pathology, or varying T2* due to BOLD-related changes. We conclude that linewidth effects need to be rigorously considered during experimental design and data processing, for example by incorporating linewidth into statistical analysis of modelling outcomes or development of appropriate lineshape matching algorithms.

8.
Mol Imaging Biol ; 26(3): 459-472, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38811467

RESUMEN

PURPOSE: Our study aimed to accelerate the acquisition of four-dimensional (4D) spectral-spatial electron paramagnetic resonance (EPR) imaging for mouse tumor models. This advancement in EPR imaging should reduce the acquisition time of spectroscopic mapping while reducing quality degradation for mouse tumor models. PROCEDURES: EPR spectra under magnetic field gradients, called spectral projections, were partially measured. Additional spectral projections were later computationally synthesized from the measured spectral projections. Four-dimensional spectral-spatial images were reconstructed from the post-processed spectral projections using the algebraic reconstruction technique (ART) and assessed in terms of their image qualities. We applied this approach to a sample solution and a mouse Hs766T xenograft model of human-derived pancreatic ductal adenocarcinoma cells to demonstrate the feasibility of our concept. The nitroxyl radical imaging agent 2H,15N-DCP was exogenously infused into the mouse xenograft model. RESULTS: The computation code of 4D spectral-spatial imaging was tested with numerically generated spectral projections. In the linewidth mapping of the sample solution, we achieved a relative standard uncertainty (standard deviation/| mean |) of 0.76 µT/45.38 µT = 0.017 on the peak-to-peak first-derivative EPR linewidth. The qualities of the linewidth maps and the effect of computational synthesis of spectral projections were examined. Finally, we obtained the three-dimensional linewidth map of 2H,15N-DCP in a Hs766T tumor-bearing leg in vivo. CONCLUSION: We achieved a 46.7% reduction in the acquisition time of 4D spectral-spatial EPR imaging without significantly degrading the image quality. A combination of ART and partial acquisition in three-dimensional raster magnetic field gradient settings in orthogonal coordinates is a novel approach. Our approach to 4D spectral-spatial EPR imaging can be applied to any subject, especially for samples with less variation in one direction.


Asunto(s)
Estudios de Factibilidad , Animales , Espectroscopía de Resonancia por Spin del Electrón/métodos , Humanos , Línea Celular Tumoral , Ratones , Modelos Animales de Enfermedad , Neoplasias Pancreáticas/diagnóstico por imagen , Neoplasias Pancreáticas/patología , Procesamiento de Imagen Asistido por Computador/métodos
9.
Nanomaterials (Basel) ; 14(15)2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-39120388

RESUMEN

The achievement of size uniformity and monodispersity in perovskite quantum dots (QDs) requires the implementation of precise temperature control and the establishment of optimal reaction conditions. Nevertheless, the accurate control of a range of reaction variables represents a considerable challenge. This study addresses the aforementioned challenge by employing manganese (Mn) doping to achieve size uniformity in CsPbBr3 perovskite QDs without the necessity for the precise control of the reaction conditions. By optimizing the Mn:Pb ratio, it is possible to successfully dope CsPbBr3 QDs with the appropriate concentrations of Mn²âº and achieve a uniform size distribution. The spectroscopic measurements on single QDs indicate that the appropriate Mn²âº concentrations can result in a narrower spectral linewidth, a longer photoluminescence (PL) lifetime, and a reduced biexciton Auger recombination rate, thus positively affecting the PL properties. This study not only simplifies the size control of perovskite QDs but also demonstrates the potential of Mn-doped CsPbBr3 QDs for narrow-linewidth light-emitting diode applications.

10.
Front Chem ; 12: 1441517, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38939164
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA