Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 353
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Environ Res ; 250: 118339, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38325791

RESUMEN

Combustion is an effective and cost-efficient thermochemical conversion method for solid waste, showing promise for the resource utilization of shoe manufacturing waste (SMW). However, SMW is generally composed of different components, which can lead to unstable combustion and excessive pollutant emissions, especially NOx. To date, combustion characteristics, reaction mechanism and fuel nitrogen (fuel-N) conversion of different SMW components remain unclear. In this work, the combustion behavior of typical SMW components combustion was investigated using Thermogravimetric coupled with Fourier transform infrared spectrum (TG-FTIR). A simplified single-step reaction mechanism was proposed according to the temperature interval to estimate reaction mechanism of SMW. Additionally, the relationship between fuel-N conversion tendency and fuel properties was established. The results indicate that the values for the comprehensive combustion performance index (S) and flammability index (C) range from 1.65 to 0.44 and 3.98 to 1.37, respectively. This demonstrates the significant variability in combustion behavior among different SMW components. Cardboard, leather and sponge have higher values of S and C, suggesting a better ignition characteristic and a stable combustion process. During the combustion of SMW, nitrogen oxides (NO and N2O) are the main nitrogen-containing compounds in the flue gases, with NO being the major contributor, accounting for over 82.97 % of the nitrogen oxides. NO has a negative correlation with nitrogen content, but it is opposite for N2O, HCN and NH3. Furthermore, the conversion of NO, N2O and NH3 is proportional to logarithmic values of O/N, while its conversion to HCN is proportional to logarithmic values of VM/N. These findings facilitate the prediction of the fuel-N conversion of solid waste combustion. This work might shed light on combustion optimization and in-situ pollutant emission control in solid waste combustion.


Asunto(s)
Zapatos , Cinética , Residuos Industriales/análisis , Nitrógeno/análisis , Incineración , Espectroscopía Infrarroja por Transformada de Fourier , Termogravimetría , Contaminantes Atmosféricos/análisis , Óxidos de Nitrógeno/análisis
2.
Eur J Appl Physiol ; 124(4): 1143-1149, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37922023

RESUMEN

PURPOSE: The aim of this study was to explore the ergogenic effect of advanced footwear technology (AFT) upon world-class male marathon running speed. METHOD: A retrospective analysis of 99 world-class male marathon runners' performances between 2012 and 2021 was undertaken, providing a sample size of 971 performances, split into two footwear groups: AFT (n = 299) and traditional (n = 672). Additionally, details regarding the year of the marathon performance and racecourse were extracted. A mixed model for repeated measures (MMRM) analysis were undertaken identifying athlete (Wald Z = 2.821; p = .005) and course (Wald Z = 4.111; p < 0.001) as significant contributors to the variance in marathon running speed and as such were included as random factors with footwear type set as a fixed factor. RESULTS: World-class male marathon running speeds were significantly faster (p < 0.001) when running in AFT (5.441 m.s-1) when compared with traditional shoes (5.386 m.s-1) with a mean difference of 0.055 m.s-1 (95% CI 0.039-0.071 m.s-1), translating to an improvement in marathon speed of 1.0% or a 79 s improvement in marathon race time. CONCLUSION: Our findings demonstrate an improvement in world-class male marathon running speed of 1% when running in AFT, a near identical degree of improvement to the male marathon world record ran in AFT. Whilst a 1% improvement in marathon running times associated with AFT is smaller than previously predicted utilizing laboratory-based models, this still reflects a significant degree of improvement at the elite level.


Asunto(s)
Carrera de Maratón , Carrera , Humanos , Masculino , Estudios Retrospectivos , Factores de Tiempo , Zapatos
3.
J Biomech Eng ; 146(4)2024 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-38217109

RESUMEN

Shoe manufacturing technology is advancing faster than new shoe designs can viably be evaluated in human subject trials. To aid in the design process, this paper presents a model for estimating how new shoe properties will affect runner performance. This model assumes runners choose their gaits to optimize an intrinsic, unknown objective function. To learn this objective function, a simple two-dimensional mechanical model of runners was used to predict their gaits under different objectives, and the resulting gaits were compared to data from real running trials. The most realistic model gaits, i.e., the ones that best matched the data, were obtained when the model runners minimized the impulse they experience from the ground as well as the mechanical work done by their leg muscles. Using this objective function, the gait and thus performance of running under different shoe conditions can be predicted. The simple model is sufficiently sensitive to predict the difference in performance of shoes with disruptive designs but cannot distinguish between existing shoes whose properties are fairly similar. This model therefore is a viable tool for coarse-grain exploration of the design space and identifying promising behaviors of truly novel shoe materials and designs.


Asunto(s)
Carrera , Zapatos , Humanos , Fenómenos Biomecánicos , Pierna , Músculo Esquelético , Carrera/fisiología
4.
Contact Dermatitis ; 90(1): 51-59, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37750414

RESUMEN

BACKGROUND: Footwear contact allergy is caused by exposure to allergens in shoes. The prevalence and common allergens vary by region and time due to differences in customs and lifestyle. OBJECTIVES: To determine the clinical characteristics and common allergens of patients with footwear-related allergic contact dermatitis (ACD) who attended Siriraj Hospital in Bangkok, Thailand, between 2001 and 2020. METHODS: The medical records of 247 patients with clinically suspected footwear dermatitis who underwent patch testing were reviewed. RESULTS: The prevalence of ACD to footwear was 1.8%. Females were predominant (71.6%). The three most common allergens were carba mix (7.7%), mercapto mix (6.9%) and potassium dichromate (6.9%). According to the allergens found, rubber (14.2%), adhesives (7.7%) and leathers (6.9%) were the three most common groups. Dorsal-limited skin lesions were significantly associated with footwear ACD. CONCLUSION: Rubber and leather allergens were still the most common culprit allergens. Dermatologists should keep up-to-date on common allergens in footwear and emerging allergens to include in patch test series.


Asunto(s)
Dermatitis Alérgica por Contacto , Dermatosis del Pie , Femenino , Humanos , Dermatitis Alérgica por Contacto/diagnóstico , Dermatitis Alérgica por Contacto/epidemiología , Dermatitis Alérgica por Contacto/etiología , Alérgenos/efectos adversos , Prevalencia , Goma , Tailandia/epidemiología , Dermatosis del Pie/epidemiología , Dermatosis del Pie/etiología , Pruebas del Parche/efectos adversos , Estudios Retrospectivos
5.
J Sports Sci ; 42(3): 247-254, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38456685

RESUMEN

Volleyball-specific footwear with higher collar heights (a mid-cut shoe) are worn to restrict ankle motion. Reduced ankle dorsiflexion has been associated with increased frontal plane motion and injury risk at the knee. With the high frequency of unilateral landings in volleyball, the purpose of this study was to determine the effect of volleyball-specific shoes and limb dominance on knee landing mechanics in collegiate volleyball players. It was hypothesized that participants would exhibit smaller sagittal plane and greater frontal plane knee joint mechanics in mid-cut and dominant limb and that vertical and posterior directed ground reaction forces would be greater wearing mid-cut, yet similar between limbs. Seventeen female volleyball players performed unilateral landings on each limb in mid-cut and low-top volleyball shoes. For shoe main effects, smaller peak dorsiflexion angle and internal peak plantarflexion moment and greater peak medial ground reaction force were found in the mid-cut but with no impact on knee mechanics. For limb main effects, the internal peak knee abduction moment was greater in the dominant limb. Greater peak lateral ground reaction force was found in the interaction between the non-dominant limb and low-top. Further research is warranted to better understand shoe and limb impact in volleyball players.


Asunto(s)
Articulación de la Rodilla , Zapatos , Voleibol , Humanos , Voleibol/fisiología , Femenino , Fenómenos Biomecánicos , Adulto Joven , Articulación de la Rodilla/fisiología , Equipo Deportivo , Lateralidad Funcional/fisiología , Diseño de Equipo
6.
J Wound Care ; 32(9): 587-596, 2023 Sep 02.
Artículo en Inglés | MEDLINE | ID: mdl-37682784

RESUMEN

OBJECTIVE: To investigate reliability and changes of in-shoe plantar pressure and shear during walking at three cadences with two insole designs. This was a precursor to the investigation of plantar loading in people with diabetes for potential foot ulcer prevention. METHOD: A sensorised insole system, capable of measuring plantar pressure and shear at the heel, fifth metatarsal head (5MH), first metatarsal head (1MH) and hallux, was tested with ten healthy participants during level walking. Reliability was evaluated, using intra-class correlation coefficient (ICC), while varying the cadences and insole types. Percentage changes in pressure and shear relative to values obtained at self-selected cadence with a flat insole design were investigated. RESULTS: Mean±standard deviation of maximum pressure, medial-lateral and anterior-posterior shear of up to 380±24kPa, 46±2kPa and -71±4kPa, respectively, were measured. The ICC in ranges of 0.762-0.973, 0.758-0.987 and 0.800-0.980 were obtained for pressure, anterior-posterior and medial-lateral shear, respectively. Opposite anterior-posterior shear directions between 5MH and 1MH (stretching), and between 1MH and hallux (pinching) were observed for some participants. Increasing cadence increased pressure and anterior-posterior shear (by up to +77%) but reduced medial-lateral shear at the heel and hallux (by up to -34%). Slower cadence increased anterior-posterior shear (+114%) but decreased medial-lateral shear (-46%) at the hallux. The use of a flexible contoured insole resulted in pressure reduction at the heel and 5MH but an increase in anterior-posterior shear at the heel (+69%) and hallux (+75%). CONCLUSION: The insole system demonstrated good reliability and is comparable to reported pressure-only systems. Pressure measurements were sensitive to changes in cadence and insole designs in ways that were consistent with the literature. However, our plantar shear showed localised shear changes with cadences and insoles for the first time, as well as stretching and pinching effects on plantar tissue. This opens new possibilities to investigate plantar tissue viability, loading characteristics and orthotic designs aimed towards foot ulcer prevention.


Asunto(s)
Diabetes Mellitus , Pie Diabético , Humanos , Pie Diabético/prevención & control , Reproducibilidad de los Resultados , Zapatos , Voluntarios Sanos , Caminata
7.
Sensors (Basel) ; 23(4)2023 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-36850921

RESUMEN

The objective of the research presented in this paper was to provide a novel open-source strain gauge system that shall enable the measurement of the pressure of a runner's feet on the ground and the presentation of the results of that measurement to the user. The system based on electronic shoe inserts with 16 built-in pressure sensors laminated in a transparent film was created, consisting of two parts: a mobile application and a wearable device. The developed system provides a number of advantages in comparison with existing solutions, including no need for calibration, an accurate and frequent measurement of pressure distribution, placement of electronics on the outside of a shoe, low cost, and an open-source approach to encourage enhancements and open collaboration.

8.
Sensors (Basel) ; 23(4)2023 Feb 20.
Artículo en Inglés | MEDLINE | ID: mdl-36850951

RESUMEN

This study characterized the absolute pressure measurement error and reliability of a new fully integrated (Kinetyx, SI) plantar-pressure measurement system (PPMS) versus an industry-standard PPMS (F-Scan, Tekscan) during an established benchtop testing protocol as well as via a research-grade, instrumented treadmill (Bertec) during a running protocol. Benchtop testing results showed that both SI and F-Scan had strong positive linearity (Pearson's correlation coefficient, PCC = 0.86-0.97, PCC = 0.87-0.92; RMSE = 15.96 ± 9.49) and mean root mean squared error RMSE (9.17 ± 2.02) compared to the F-Scan on a progressive loading step test. The SI and F-Scan had comparable results for linearity and hysteresis on a sinusoidal loading test (PCC = 0.92-0.99; 5.04 ± 1.41; PCC = 0.94-0.99; 6.15 ± 1.39, respectively). SI had less mean RMSE (6.19 ± 1.38) than the F-Scan (8.66 ±2.31) on the sinusoidal test and less absolute error (4.08 ± 3.26) than the F-Scan (16.38 ± 12.43) on a static test. Both the SI and F-Scan had near-perfect between-day reliability interclass correlation coefficient, ICC = 0.97-1.00) to the F-Scan (ICC = 0.96-1.00). During running, the SI pressure output had a near-perfect linearity and low RMSE compared to the force measurement from the Bertec treadmill. However, the SI pressure output had a mean hysteresis of 7.67% with a 28.47% maximum hysteresis, which may have implications for the accurate quantification of kinetic gait measures during running.


Asunto(s)
Prueba de Esfuerzo , Carrera , Reproducibilidad de los Resultados , Marcha , Industrias
9.
Sensors (Basel) ; 23(12)2023 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-37420613

RESUMEN

Frailty poses a threat to the daily lives of healthy older adults, highlighting the urgent need for technologies that can monitor and prevent its progression. Our objective is to demonstrate a method for providing long-term daily frailty monitoring using an in-shoe motion sensor (IMS). We undertook two steps to achieve this goal. Firstly, we used our previously established SPM-LOSO-LASSO (SPM: statistical parametric mapping; LOSO: leave-one-subject-out; LASSO: least absolute shrinkage and selection operator) algorithm to construct a lightweight and interpretable hand grip strength (HGS) estimation model for an IMS. This algorithm automatically identified novel and significant gait predictors from foot motion data and selected optimal features to construct the model. We also tested the robustness and effectiveness of the model by recruiting other groups of subjects. Secondly, we designed an analog frailty risk score that combined the performance of the HGS and gait speed with the aid of the distribution of HGS and gait speed of the older Asian population. We then compared the effectiveness of our designed score with the clinical expert-rated score. We discovered new gait predictors for HGS estimation via IMSs and successfully constructed a model with an "excellent" intraclass correlation coefficient and high precision. Moreover, we tested the model on separately recruited subjects, which confirmed the robustness of our model for other older individuals. The designed frailty risk score also had a large effect size correlation with clinical expert-rated scores. In conclusion, IMS technology shows promise for long-term daily frailty monitoring, which can help prevent or manage frailty for older adults.


Asunto(s)
Fragilidad , Humanos , Anciano , Fragilidad/diagnóstico , Zapatos , Anciano Frágil , Fuerza de la Mano , Marcha , Evaluación Geriátrica/métodos
10.
Sensors (Basel) ; 23(15)2023 Jul 28.
Artículo en Inglés | MEDLINE | ID: mdl-37571530

RESUMEN

In-shoe models are required to extend the clinical application of current multisegment kinetic models of the bare foot to study the effect of foot orthoses. Work to date has only addressed marker placement for reliable kinematic analyses. The purpose of this study is to address the difficulties of recording contact forces with available sensors. Ten participants walked 5 times wearing two different types of footwear by stepping on a pressure platform (ground contact forces) while wearing in-shoe pressure sensors (foot sole contact forces). Pressure data were segmented by considering contact cells' anteroposterior location, and were used to compute 3D moments at foot joints. The mean values and 95% confidence intervals were plotted for each device per shoe condition. The peak values and times of forces and moments were computed per participant and trial under each condition, and were compared using mixed-effect tests. Test-retest reliability was analyzed by means of intraclass correlation coefficients. The curve profiles from both devices were similar, with higher joint moments for the instrumented insoles at the metatarsophalangeal joint (~26%), which were lower at the ankle (~8%) and midtarsal (~15%) joints, although the differences were nonsignificant. Not considering frictional forces resulted in ~20% lower peaks at the ankle moments compared to previous studies, which employed force plates. The device affected both shoe conditions in the same way, which suggests the interchangeability of measuring joint moments with one or the other device. This hypothesis was reinforced by the intraclass correlation coefficients, which were higher for the peak values, although only moderate-to-good. In short, both considered alternatives have drawbacks. Only the instrumented in-soles provided direct information about foot contact forces, but it was incomplete (evidenced by the difference in ankle moments between devices). However, recording ground reaction forces offers the advantage of enabling the consideration of contact friction forces (using force plates in series, or combining a pressure platform and a force plate to estimate friction forces and torque), which are less invasive than instrumented insoles (which may affect subjects' gait).


Asunto(s)
Pie , Zapatos , Humanos , Reproducibilidad de los Resultados , Marcha , Articulaciones del Pie , Fenómenos Biomecánicos
11.
Sensors (Basel) ; 23(17)2023 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-37687875

RESUMEN

Rapid significant weight fluctuations can indicate severe health conditions such as edema due to congestive heart failure or severe dehydration that could require prompt intervention. Daily body weighing does not accurately represent the patient's body weight fluctuations occurring within a day. The patient's lack of compliance with tracking their weight measurements is also a predominant issue. Using shoe insole sensors embedded into footwear could achieve accurate real-time monitoring systems for estimating continuous body weight changes. Here, the machine learning models' predictive capabilities for continuous real-time weight estimation using the insole data are presented. The lack of availability of public datasets to feed these models is also addressed by introducing two novel datasets. The proposed framework is designed to adapt to the patient, considering several unique factors such as shoe type, posture, foot shape, and gait pattern. The proposed framework estimates the mean absolute percentage error of 0.61% and 0.74% and the MAE of 1.009 lbs. and 1.154 lbs. for the less controlled and more controlled experimental settings, respectively. This will help researchers utilize machine learning techniques for more accurate real-time continuous weight estimation using sensor data and enable more reliable aging-in-place monitoring and telehealth.


Asunto(s)
Sistemas de Computación , Zapatos , Humanos , Deshidratación , Aprendizaje Automático , Peso Corporal
12.
Sensors (Basel) ; 23(21)2023 Nov 05.
Artículo en Inglés | MEDLINE | ID: mdl-37960684

RESUMEN

We developed a shoe sole sensor system with four high-capacity, compact triaxial force sensors using a nitrogen added chromium strain-sensitive thin film mounted on the sole of a shoe. Walking experiments were performed, including straight walking and turning (side-step and cross-step turning), in six healthy young male participants and two healthy young female participants wearing the sole sensor system. A regression model to predict three-directional ground reaction forces (GRFs) from force sensor outputs was created using multiple linear regression and Gaussian process regression (GPR). The predicted GRF values were compared with the GRF values measured with a force plate. In the model trained on data from the straight walking and turning trials, the percent root-mean-square error (%RMSE) for predicting the GRFs in the anteroposterior and vertical directions was less than 15%, except for the GRF in the mediolateral direction. The model trained separately for straight walking, side-step turning, and cross-step turning showed a %RMSE of less than 15% in all directions in the GPR model, which is considered accurate for practical use.


Asunto(s)
Marcha , Zapatos , Humanos , Masculino , Femenino , Fenómenos Biomecánicos , Caminata , Aprendizaje Automático
13.
J Environ Manage ; 331: 117304, 2023 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-36657197

RESUMEN

Clothing and footwear designed for trail running shed microplastics (MPs) during use. Trail running events may therefore present a significant source of MP pollution in conservation and wilderness areas. Microplastics may present long-term risks to biodiversity and endemic plant and animal species in such areas. In this study, we used a before-after-control-impact approach to quantify and characterise MP emissions from clothing and shoe outsoles during trail running events. Microplastic deposition on trail surfaces was assessed using both a controlled study and during two public trail running events in New South Wales, Australia (the Duval Dam Buster and the Washpool World Heritage Trail Race). Microplastics were present on trails after all events and included fibres and rubber fragments. Microplastic counts varied considerably depending on trail surface hardness and gradient, and clothing and footwear properties. The controlled study showed running tights (leggings) and shoes with soft rubber outsoles produced more MPs than shirts and hard rubbers. In the trail running events, abrasive wear to shoe outsoles produced an average of 0.3 ± 0.1 to 0.9 ± 0.2 MPs/linear metre/runner, and clothing produced 0.7 ± 0.3 to 2.0 ± 0.3 fibres/linear metre/runner, with fibres accounting for 63-69% of MPs. Microplastic deposition from both footwear and clothing was higher on sloped and rock trail surfaces than flat and soil surfaces. Laser Direct Infrared (LDIR) Imaging indicated the main types of MPs present on trails were polyurethane, polyethylene terephthalate and polyamide. Trail running is increasing in popularity and large-scale events may cause a rapid and significant input of MPs in protected areas. Land managers, event coordinators and outdoor apparel manufacturers could mitigate MP impacts however, by diverting foot traffic around ecologically sensitive areas, capping participant numbers, and developing abrasion resistant clothing and footwear.


Asunto(s)
Carrera , Contaminantes Químicos del Agua , Animales , Humanos , Microplásticos , Plásticos , Goma , Vida Silvestre , Monitoreo del Ambiente , Contaminantes Químicos del Agua/análisis
14.
BMC Pediatr ; 22(1): 187, 2022 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-35395740

RESUMEN

BACKGROUND: Research shows that ill-fitting shoes can negatively impact the development of the pediatric foot, in a very direct manner. The primary aim of the study was to determine if the dimensions of available prescribed school shoes fit the foot dimensions of habitually barefoot South African children and adolescents. METHODS: A cross-sectional observational study was conducted where static standing foot measurements of children and adolescents from urban and rural schools were obtained with a mobile caliper. The maximum heel-toe-length and foot width with an added 10 mm toe- and width fit allowance to each participant, were compared to the corresponding school shoe length and shoe width available in retail. A mixed model ANOVA was used to compare foot dimensions between gender, age and side. RESULTS: Six hundred and ninety-eight school children (N = 698) (431 girls; 267 boys; average age 10.86 years, SD = 2.55) were participants. A total of seventy-seven (N = 77) black coloured prescribed school shoes currently available in retail ranging from different styles and brands were measured. Results show that, comparing the shoe length and maximum heel-toe-length of participants, as well as taking 10 mm toe allowance into account, fifty-nine percent (59%) of children wore shoes that were not the correct length. With regards to the shoe width and the added 10 mm of width fit allowance, ninety-eight percent (98%) of the shoes worn by participants were too narrow for their feet. CONCLUSIONS: Results confirmed that school shoes currently available in retail, are not suited for the habitually barefoot population studied. It is recommended that the shoe manufacturing industry should consider the shoe width of school shoes for children and adolescents in habitually barefoot populations to avoid the long-term negative effect of ill-fitting shoes on the pediatric foot.


Asunto(s)
Pie , Zapatos , Adolescente , Fenómenos Biomecánicos , Niño , Estudios Transversales , Femenino , Humanos , Extremidad Inferior , Masculino , Instituciones Académicas
15.
Drug Chem Toxicol ; 45(4): 1907-1914, 2022 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33715556

RESUMEN

This study aimed to investigate the potential hepatotoxicity, nephrotoxic, and hematotoxic effects of simultaneous occupational low-level exposure of shoe workers to a mixture of organic solvents. The study included 16 male and 55 female workers and non-exposed subjects (n = 60) in the control group. Along with a standard sets of hematological, liver enzymes (aspartate aminotransferase (AST), alanine aminotransferase (ALT) and gamma-glutamyl transpeptidase (GGT), bilirubin total, bilirubin direct, blood glucose, urea, and creatinine were analyzed in all participants. Indoor air quality was monitored using a Gasmet Dx - 4000 multi-component analyzer. Despite the concentration levels of individual chemicals in shoe production units were below the permissible limits, the equivalent exposure (Em) values calculated based on the American Conference of Governmental Industrial Hygienists (ACGIH) and National Institute of Occupational Safety and Health (NIOSH) occupational exposure limits were higher than 1. Statistically significant increase of biochemical parameters (aspartate aminotransferase (AST), gamma-glutamyl transpeptidase (GGT), total bilirubin, and direct bilirubin) was obtained in exposed workers of both genders compared with controls (p < 0.001). Calculated liver damage risk scores were significantly higher in both females and males compared with controls (p < 0.001). The multivariate logistic regression analysis showed that direct bilirubin was the most important predictor of organic solvent mixture exposure in the studied group of workers. These results suggest that combined exposure to organic solvents even at low concentrations may lead to hepatotoxicity.


Asunto(s)
Enfermedad Hepática Inducida por Sustancias y Drogas , Exposición Profesional , Alanina Transaminasa , Aspartato Aminotransferasas , Bilirrubina/análisis , Enfermedad Hepática Inducida por Sustancias y Drogas/etiología , Femenino , Humanos , Masculino , Exposición Profesional/efectos adversos , Zapatos , Solventes/toxicidad , gamma-Glutamiltransferasa
16.
J Sports Sci ; 40(12): 1351-1359, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35648799

RESUMEN

This study assessed whether grip socks reduce in-shoe foot motion and improve change of direction performance in team sports players and compared the effects between males and females. A sledge and pulley system confirmed the static coefficient of friction was increased in the grip socks (1.17) compared to the regular socks (0.60). Performance during a slalom course was faster in the grip socks compared to regular socks (p = .001). Yet, there was no difference in the utilised coefficient of friction between the shoe-floor interface during a side-cut and turn change of direction manoeuvre. Three-dimensional motion capture revealed the grip socks reduced in-shoe foot displacement during the braking phase, with greater effect during the sharper turn manoeuvre. The magnitude of natural foot spreading within the shoe was greater in the calcaneus region than the metatarsals which suggests in-shoe sliding may only occur at the forefoot. Males tended to have increased in-shoe displacement, which is associated with larger foot spreading due to their increased mass. Findings provide guidance for product developers to enhance the support inside the shoe at the forefoot, and change of direction performance.


Asunto(s)
Zapatos , Deportes , Femenino , Pie , Fricción , Fuerza de la Mano , Humanos , Masculino
17.
Sensors (Basel) ; 22(7)2022 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-35408358

RESUMEN

This paper presents a plantar pressure sensor system (P2S2) integrated in the insoles of shoes to detect thirteen commonly used human movements including walking, stooping left and right, pulling a cart backward, squatting, descending, ascending stairs, running, and falling (front, back, right, left). Six force sensitive resistors (FSR) sensors were positioned on critical pressure points on the insoles to capture the electrical signature of pressure change in the various movements. A total of 34 adult participants were tested with the P2S2. The pressure data were collected and processed using a Principal Component Analysis (PCA) for input to the multiple machine learning (ML) algorithms, including k-NN, neural network and Support-Vector Machine (SVM) algorithms. The ML models were trained using four-fold cross-validation. Each fold kept subject data independent from other folds. The model proved effective with an accuracy of 86%, showing a promising result in predicting human movements using the P2S2 integrated in shoes.


Asunto(s)
Zapatos , Caminata , Adulto , Humanos , Aprendizaje Automático , Movimiento , Presión
18.
Sensors (Basel) ; 22(1)2022 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-35009893

RESUMEN

To expand the potential use of in-shoe motion sensors (IMSs) in daily healthcare or activity monitoring applications for healthy subjects, we propose a real-time temporal estimation method for gait parameters concerning bilateral lower limbs (GPBLLs) that uses a single IMS and is based on a gait event detection approach. To validate the established methods, data from 26 participants recorded by an IMS and a reference 3D motion analysis system were compared. The agreement between the proposed method and the reference system was evaluated by the intraclass correlation coefficient (ICC). The results showed that, by averaging over five continuous effective strides, all time parameters achieved precisions of no more than 30 ms and agreement at the "excellent" level, and the symmetry indexes of the stride time and stance phase time achieved precisions of 1.0% and 3.0%, respectively, and agreement at the "good" level. These results suggest our method is effective and shows promise for wide use in many daily healthcare or activity monitoring applications for healthy subjects.


Asunto(s)
Marcha , Zapatos , Fenómenos Biomecánicos , Pie , Voluntarios Sanos , Humanos , Extremidad Inferior
19.
Arch Orthop Trauma Surg ; 142(1): 77-81, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32880704

RESUMEN

INTRODUCTION: After surgical treatment of injuries of the lower extremity, partial weight bearing is often suggested until soft tissue consolidation. It is doubtful, if this recommendation can be implemented, even in the case that a patient is performing partial weight bearing with a physical therapist. Consequently the question remains, if patients are able to implement partial weight bearing after surgery and which factors favor incompliance. MATERIALS AND METHODS: 49 patients, who underwent surgical treatment after injuries of the lower extremity, were equipped with electronic shoe insoles on both sides. Different weight bearing instructions were given depending on the type of injury and surgery (full weight bearing vs. 20 kg weight bearing vs. non-weight bearing). Besides loading, other factors like age, gender, weight and physical activity were evaluated. Statistical analysis was performed using Chi-square and Fisher's exact test with significance set at a p value < 0.05. RESULTS: 25 of the 40 patients, who had to perform non- or partial weight bearing, were not able to follow postoperative instructions (compliance rate 37.5%). The average loading of the whole collective was 32.6 kg (4.8-109.2 kg). The specification of loading had no statistically significant influence on real loading (p-value 0.39). Elderly patients were less able to follow instructions than younger patients (36 vs 30.2 kg). Physically active compared to non-active patients overloaded their injured extremity (37.8 vs 28.7 kg). Patients with a high body mass index (BMI) encountered more difficulties to perform partial weight bearing than lightweight patients (36.9 vs 25.1 kg). CONCLUSIONS: Most patients were not able to follow loading limitation, even a few days after surgery and even if the patients were trained by a physiotherapist. Excessive weight bearing-related complications should be evaluated.


Asunto(s)
Extremidad Inferior , Cooperación del Paciente , Anciano , Humanos , Extremidad Inferior/cirugía , Periodo Posoperatorio , Soporte de Peso
20.
J Foot Ankle Surg ; 61(3): 479-481, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34706858

RESUMEN

Nail puncture wounds through rubber-soled shoes, when presenting acutely, have a deceivingly benign appearance. High index of suspicion for a retained rubber piece should be maintained by the physician. This study investigates whether preoperative ultrasound examination can rule out a foreign body and reduce the need for surgery. It is a retrospective cohort of 125 patients with deep nail puncture wounds through a rubber-soled shoe, who underwent surgical exploration between 2008 and 2018. All patients had a preoperative ultrasound examination for detection of a rubber foreign body. The patients' median age was 29, and 112 (89.6%) were males. Median time of presentation was 1 day, but there were patients who presented up to 90 days after injury (mean 5.1 ± 15.6 days). Foreign bodies, ranging 1 to 4 mm in diameter, were surgically removed in 37 (29.6%) patients. Only 16 of these patients had a positive preoperative ultrasound examination, corresponding to sensitivity of 43.2%. Specificity of the ultrasound examination was 95%. Ultrasound examination has low sensitivity for detection of foreign bodies following a puncture wound of the foot. This is attributable to the small size of the foreign bodies in this scenario and to the complexity of sonography in this location. We conclude that ultrasound cannot be used to rule out foreign body in the foot, and should not be relied on when deciding to avoid surgery. Nevertheless, it can be a helpful adjunct preoperatively, as an assessment of the foreign body size and location.


Asunto(s)
Cuerpos Extraños , Zapatos , Femenino , Cuerpos Extraños/diagnóstico por imagen , Cuerpos Extraños/cirugía , Humanos , Masculino , Quirófanos , Punciones , Estudios Retrospectivos , Goma
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA