1.
Graefes Arch Clin Exp Ophthalmol ; 262(4): 1245-1252, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37938376

RESUMEN

PURPOSE: To evaluate the anterior segment structures using ultrasound biomicroscopy (UBM) in primary congenital glaucoma (PCG) and explore their correlation with disease severity and surgical outcomes. METHODS: Clinical information of PCG patients who underwent UBM prior to their first glaucoma surgeries from September 2014 to March 2021 were reviewed. The study included 214 UBM images of 154 PCG eyes and 60 fellow unaffected eyes. Anterior segment characteristics were analyzed. UBM parameters, including the iris thickness (IT) at variant distances from the pupil edge and iris root, anterior chamber depth (ACD), and pupil diameter (PD), were compared between two groups and their relationship with clinical factors and surgical outcomes were analyzed in PCG eyes. RESULTS: PCG eyes had unclear scleral spur, thin iris, wide anterior chamber angle, deep anterior chamber, rarefied ciliary body, elongated ciliary processes, and abnormal anterior iris insertion. ITs were thinner, ACD was deeper, and PD was larger in PCG eyes than fellow unaffected eyes (all P < 0.001). In PCG eyes, thinner ITs correlated with bilateral involvement and earlier age at presentation, and larger PD correlated with earlier age at presentation (P = 0.030) and higher intraocular pressure (P < 0.001). Thinner IT2 (P = 0.046) and larger PD (P = 0.049) were identified as risk factors for surgical failure. CONCLUSION: UBM is a powerful technique to exam anterior segment structures in PCG. The anatomical features are associated with disease severity and surgical outcomes, providing essential clinical insights.


Asunto(s)
Glaucoma de Ángulo Cerrado , Glaucoma , Humanos , Microscopía Acústica/métodos , Cuerpo Ciliar/diagnóstico por imagen , Iris/diagnóstico por imagen , Glaucoma/diagnóstico , Glaucoma/cirugía , Glaucoma/congénito , Gravedad del Paciente , Resultado del Tratamiento , Glaucoma de Ángulo Cerrado/cirugía , Segmento Anterior del Ojo/diagnóstico por imagen , Presión Intraocular
2.
BMC Ophthalmol ; 24(1): 34, 2024 Jan 23.
Artículo en Inglés | MEDLINE | ID: mdl-38263030

RESUMEN

BACKGROUND: The structural features have an impact on the surgical prognosis for congenital corneal opacity (CCO). The structural classification system of CCO, however, is lacking. Based on data from ultrasound biomicroscopy (UBM) findings in infants and toddlers with CCO, this research proposed a classification system for the anterior segment structure severity. METHODS: Medical records, preoperative UBM images and slit-lamp photographs of infants and toddlers diagnosed with CCO at University Third Hospital between December 2018 and June 2022 were reviewed. According to the anterior segment structural features observed in UBM images, eyes were classified as follows: U1, opaque cornea only; U2, central anterior synechia; U3, peripheral anterior synechia combined with angle closure; and U4, aniridia or lens anomaly. The opacity appearance and corneal vascularization density observed in slit-lamp photographs were assigned grades according to previous studies. The extent of vascularization was also recorded. The corresponding intraocular anomaly classifications and ocular surface lesion severity were analysed. RESULTS: Among 81 eyes (65 patients), 41 (50.6%) were right eyes, and 40 (49.4%) were left eyes. The median age at examination was 6.91 months (n = 81, 1.00, 34.00). Two (2.5%) of the 81 eyes were classified as U1, 20 (24.7%) as U2, 22 (27.2%) as U3a, 11 (13.6%) as U3b and 26 (32.1%) as U4. Bilateral CCO eyes had more severe UBM classifications (P = 0.019), more severe dysgenesis (P = 0.012) and a larger angle closure (P = 0.009). Eyes with more severe UBM classifications had higher opacity grades (P = 0.003) and vascularization grades (P = 0.014) and a larger vascularization extent (P = 0.001). Eyes with dysgenesis had higher haze grades (P = 0.012) and more severe vascularization (P = 0.003 for density; P = 0.008 for extent), while the angle closure range was related to haze grade (P = 0.013) and vascularization extent (P = 0.003). CONCLUSIONS: This classification method based on UBM and slit-lamp photography findings in the eyes of CCO infants and toddlers can truly reflect the degree of abnormality of the ocular surface and anterior segment and is correlated with the severity of ocular surface anomalies. This method might provide meaningful guidance for surgical procedure design and prognostic determinations for keratoplasty in CCO eyes.


Asunto(s)
Enfermedades de la Córnea , Opacidad de la Córnea , Anomalías del Ojo , Enfermedades del Iris , Lactante , Humanos , Preescolar , Microscopía Acústica , Microscopía con Lámpara de Hendidura , Neovascularización Patológica , Córnea
3.
BMC Ophthalmol ; 24(1): 349, 2024 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-39152392

RESUMEN

BACKGROUND: Accurate prediction of postoperative vault in implantable collamer lens (ICL) implantation is crucial; however, current formulas often fail to account for individual anatomical variations, leading to suboptimal visual outcomes and necessitating improved predictive models. We aimed to verify the prediction accuracy of our new predictive model for vaulting based on anterior and posterior chamber structural parameters. METHODS: This retrospective observational study included 137 patients (240 eyes) who previously underwent ICL surgery. Patients were randomly divided into the model establishment (192 eyes) or validation (48 eyes) groups. Preoperative measurements of the anterior and posterior chamber structures were obtained using Pentacam, CASIA2 anterior segment optical coherence tomography (AS-OCT), ultrasound biomicroscopy, and other devices. Stepwise multiple linear regression analysis was used to evaluate the relationship between the vault and each variable (WL formula). The Friedman test was performed for the vaulting prediction results of the WL, NK (Ver. 3), and KS formulas (Ver. 4) in CASIA2 AS-OCT, as well as the Zhu formula and vault measurements. The proportions of prediction error within ± 250 µm per formula were compared. RESULTS: The predicted vault values of the WL, NK, KS, and Zhu formulas and vault measurements were 668.74 ± 162.12, 650.85 ± 248.47, 546.56 ± 128.99, 486.56 ± 210.76, and 716.06 ± 233.84 µm, respectively, with a significant difference (χ2 = 69.883, P = 0.000). Significant differences were also found between the measured vault value and Zhu formula, measured vault value and KS formula, WL formula and Zhu formula, WL formula and KS formula, NK formula and KS formula, and NK formula and Zhu formula (P < 0.001) but not between other groups. The proportions of prediction error within ± 250 µm per formula were as follows: WL formula (81.3%) > NK formula (70.8%) > KS formula (66.7%) > Zhu formula (54.2%). CONCLUSIONS: The WL formula, which considers the complexity of the anterior and posterior chamber structures, demonstrates greater calculation accuracy, compared with the KS (Ver. 4) and Zhu formulas. The proportion of absolute prediction error ≤ 250 µm is higher with the WL formula than with the NK formula (ver. 3). This enhanced predictive capability can improve ICL sizing decisions, thereby increasing the safety and efficacy of ICL implantation surgeries.


Asunto(s)
Implantación de Lentes Intraoculares , Tomografía de Coherencia Óptica , Humanos , Estudios Retrospectivos , Femenino , Masculino , Tomografía de Coherencia Óptica/métodos , Adulto , Implantación de Lentes Intraoculares/métodos , Cámara Anterior/diagnóstico por imagen , Lentes Intraoculares Fáquicas , Miopía/cirugía , Microscopía Acústica/métodos , Adulto Joven , Persona de Mediana Edad , Agudeza Visual , Biometría/métodos , Refracción Ocular/fisiología
4.
Clin Exp Ophthalmol ; 52(2): 186-206, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38214059

RESUMEN

Ultrasound biomicroscopy (UBM) is an invaluable investigation for imaging anterior segment structures. Although it is operator-dependent and time consuming, unlike optical-based imaging techniques, it is able to image structures posterior to the iris, such as the zonules, ciliary body and part of the pars plana. It is especially useful in advanced cataracts, traumatic cataracts, subluxed lenses, posterior polar cataracts, and congenital and developmental anomalies affecting the anterior segment. It provides diagnostic information in eyes with complex cataracts or intraocular lens (IOL)-related pathology, and aids in surgical planning in order to minimise complications. In this review, we describe the UBM features of various lenticular pathologies and demonstrate its application in the diagnosis and surgical management of lens and IOL-related pathologies.


Asunto(s)
Extracción de Catarata , Catarata , Lentes Intraoculares , Humanos , Microscopía Acústica/métodos , Implantación de Lentes Intraoculares/métodos , Catarata/diagnóstico , Extracción de Catarata/métodos
5.
Int Ophthalmol ; 44(1): 283, 2024 Jun 26.
Artículo en Inglés | MEDLINE | ID: mdl-38922523

RESUMEN

PURPOSE: To examine the rate of ciliary body detachment in patients with choroidal detachment following glaucoma surgery and its effect on the clinical course, management, and prognosis. METHODS: A prospective observational case-series study. Patients with choroidal detachment following glaucoma surgery in 2018-2019 were included. All underwent complete ophthalmological examination and ultrasound biomicroscopy for evaluation of the presence and extent of ciliary body detachment. Follow-up examinations including ultrasound biomicroscopy scans were performed at 1 week, 1 month, 3 months, and 6 months. RESULTS: Eight patients (8 eyes) were enrolled, 4 male and 4 female, of mean age 72 years (range 60-83). Five patients underwent trabeculectomy with mitomycin C (0.02%), which was combined with phacoemulsification cataract extraction in one; two underwent Ahmed glaucoma valve implantations, and one underwent ab-interno Xen45 gel stent implantation with mitomycin C (0.02%). The mean intraocular pressure was 26.0 ± 7.65 mmHg preoperatively, dropping to 6.9 ± 2.64 mmHg on first postoperative day one. Mean time from surgery to diagnosis of choroidal detachment was 11.6 ± 5.73 days. Ciliary body detachment was identified by ultrasound biomicroscopy in all patients, ranging between one and four quadrants. All patients were treated with topical steroids and cycloplegics; three (37.5%) received oral steroids. No surgical intervention for the choroidal or ciliary body detachments was indicated. CONCLUSIONS: In this real-world prospective study, concurrent ciliary body detachment was identified in all patients who presented with choroidal detachment following glaucoma surgery. This observation may deepen our understanding of the mechanism underlying the hypotony that is often seen after glaucoma surgery.


Asunto(s)
Efusiones Coroideas , Cuerpo Ciliar , Glaucoma , Presión Intraocular , Humanos , Masculino , Femenino , Anciano , Estudios Prospectivos , Persona de Mediana Edad , Anciano de 80 o más Años , Presión Intraocular/fisiología , Efusiones Coroideas/diagnóstico , Efusiones Coroideas/etiología , Glaucoma/cirugía , Glaucoma/fisiopatología , Glaucoma/complicaciones , Complicaciones Posoperatorias/diagnóstico , Microscopía Acústica , Estudios de Seguimiento , Trabeculectomía/efectos adversos , Trabeculectomía/métodos , Implantes de Drenaje de Glaucoma/efectos adversos , Agudeza Visual , Enfermedades de la Úvea/diagnóstico , Enfermedades de la Úvea/etiología , Tomografía de Coherencia Óptica/métodos
6.
Vestn Oftalmol ; 140(1): 11-18, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38450461

RESUMEN

Analysis of lens changes in Marfan syndrome (MS), in addition to assessing the position of the lens itself, should include the possibility of examining its supporting and accommodative components (ciliary zonule and ciliary body), or what can be called the entire anatomical complex of the lens. Optical methods of studying the structures of the anterior segment of the eye, due to iris opacity, allow only to analyze the state of the lens within the natural or medically enlarged pupil width. Visualization of the structures located behind the iris is possible with the use of radiation diagnostic methods, in particular ultrasound biomicroscopy (UBM). PURPOSE: This study assesses the state of the anatomical complex of the lens in MS using UBM. MATERIAL AND METHODS: The study was carried out on clinical material previously used by us to analyze changes in the fibrous membrane of the eye in MS. At the first stage, the main (19 patients with MS, 38 eyes) and the control (24 patients with myopia, 48 eyes) groups were formed for comparative evaluation. The formed groups were standardized according to the age of the patients and the axial length of the eye. At the second stage, patients with MS were divided into subgroups depending on the absence or presence of biomicroscopic signs of ectopia lentis (22 and 16 eyes, respectively). For UBM, an ultrasound linear sensor with a scanning frequency of 50 MHz was used (Aviso device, Quantel Medical, France). Various biometric UBM indicators were determined: lens thickness, diameter of the lens, lens-axial length factor, iris-lens angle, iris-lens contact distance, posterior chamber depth, length of the fibers of ciliary zonule, thickness of the ciliary body, sclera-ciliary process angle. RESULTS: There are changes in the anatomical complex of the lens as a whole in MS (in the lens itself, the ciliary zonule, and the ciliary body), which are characterized by an increase in lens thickness and a decrease in the diameter of the lens, an increase in the length of the fibers of the ciliary zonule and a decrease in the thickness of the ciliary body. At the same time, the displacement of the lens detected by optical biomicroscopy (ectopia lentis) can be considered as an advanced stage of changes in the anatomical complex of the lens. CONCLUSION: UBM provides the possibility of full-fledged visualization of all components of the anatomical complex of the lens in terms of both diagnostics, and monitoring of changes in MS. The question of the advisability of including this method in the algorithm for diagnosing ocular manifestations in order to verify the MS remains open. Possible obstacles may be, on the one hand, related to the need for special and expensive equipment, and on the other hand, the absence of a generally accepted «normal¼ values of UBM indicators of the anatomical complex of the lens.


Asunto(s)
Desplazamiento del Cristalino , Cristalino , Lentes , Síndrome de Marfan , Humanos , Desplazamiento del Cristalino/diagnóstico , Desplazamiento del Cristalino/etiología , Síndrome de Marfan/complicaciones , Síndrome de Marfan/diagnóstico , Cristalino/diagnóstico por imagen , Iris
7.
BMC Ophthalmol ; 23(1): 403, 2023 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-37803302

RESUMEN

BACKGROUND: This study aims to identify the relationship between iris -ciliary angle (ICA) and the vault. Additionally, we also seek to investigate the chain mediating effects of the ICL haptic related factors on this relationship. METHODS: The participants were categorized into three groups according to the ICA value as follows: low ICA group (< 35°); moderate ICA group (35°-70°); high ICA group (> 70°). We compared the preoperative ocular characteristics and postoperative examinations among the three groups. Multiple variable stepwise regression was performed to establish the vault prediction formula. The Process V4.0 in SPSS and Hayes's PROCESS model 6 was conducted to further elucidate the mediating effects of the final tip point of ICL haptic and the ICL arc-lens arc on the relationship between the ICA and vault. RESULTS: There was a significant difference in the positions of the ICL haptic among three ICA groups. The regression vault equation was Vault = 679.42-7.26*TCA + 192.30*ACD-196.37*CLR + 73.21* STS(horizontal).A significant negative correlation was found between the ICA and vault (P < 0.01).The chain mediation model revealed that the final tip point of ICL haptic and the ICL arc-Lens arc were sequential mediators between ICA and vault (effect = -1.63, 95% CI = -2.72--0.73). CONCLUSION: The ICA was associated with vault via the mediation effect of the final tip point of the ICL haptic and the ICL arc -lens arc. Assessment of ICL haptic related parameters adds significant information to interpret the vault after surgery.


Asunto(s)
Miopía , Lentes Intraoculares Fáquicas , Humanos , Agudeza Visual , Implantación de Lentes Intraoculares , Miopía/cirugía , Tecnología Háptica , Iris/cirugía , Estudios Retrospectivos
8.
BMC Ophthalmol ; 23(1): 480, 2023 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-37993828

RESUMEN

BACKGROUND: The spatial position of the lens in patients with cortical age-related cataract (CARC) is unclear. We investigated a basis for the assessment of visual quality after cataract surgery by analysing the ultrasound biomicroscopic characteristics of the biological parameters of the lens in patients with CARC. METHODS: In this retrospective study, 119 patients (50 males and 69 females, totalling 238 eyes) with CARC who underwent simple cataract surgery were selected. The lens thickness (LT), axial length (AL), anterior chamber depth (ACD), lens vault (LV), trabecular-iris angle (TIA), iris-lens angle (ILA), iris-lens contact distance (ILCD) were measured by A-scan ultrasound and ultrasound biomicroscopy. The corresponding lens position (LP) and relative lens position (RLP) were calculated. RESULTS: LP was greater in men than in women (P < 0.05), LV was smaller in men than in women (P = 0.002), ILA and ILCD were not statistically significant (P = 0.072 and P = 0.854, respectively). There were significant differences in TIA, ILA, and ILCD in the four quadrants (all P < 0.05), with a trend in the distribution of TIA: superior < inferior < nasal < temporal, ILA: nasal < inferior < temporal < superior, and ILCD: superior < temporal < inferior < nasal. CONCLUSIONS: The lens protrudes more obviously in females than in males and the lens tilts to a certain extent with the increase of age and tends to be more upward and temporal in the supine position. Therefore, trends in lens-related parameters in patients with CARC should be taken seriously.


Asunto(s)
Catarata , Glaucoma de Ángulo Cerrado , Cristalino , Masculino , Humanos , Femenino , Microscopía Acústica , Estudios Retrospectivos , Cristalino/diagnóstico por imagen , Cámara Anterior/diagnóstico por imagen , Iris/diagnóstico por imagen
9.
Ophthalmic Res ; 66(1): 1159-1168, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38130005

RESUMEN

INTRODUCTION: The aim of the study was to investigate the clinical characteristics and treatment outcomes of the pseudophakic eyes with malignant glaucoma (MG). METHODS: This retrospective case-control study enrolled 53 eyes of 47 patients with primary angle-closure glaucoma having cataract surgery history, including 19 patients (25 eyes) diagnosed with MG and 28 patients (28 eyes) without MG as the match. Among patients diagnosed with MG, 14 patients (18 eyes) underwent zonulo-hyaloido-vitrectomy (ZHV) and the other 5 patients (7 eyes) received conservative treatments. The visual acuity, refraction status, intraocular pressure (IOP), extent of peripheral anterior synechia, classes of anti-glaucoma medications, and ultrasound biomicroscopy (UBM) examination were recorded before cataract surgery, at the diagnosis of MG, and 3 months after ZHV or atropine application, respectively. RESULTS: In the pseudophakic eyes with MG, the IOP cannot be well controlled compared to the matched eyes (27.24 ± 8.72 mm Hg vs. 14.30 ± 2.63 mm Hg, p < 0.001). In addition, there was a difference in the average spherical equivalent refractive error between 2 groups of patients (-2.23 ± 0.84 D in MG vs. -0.12 ± 0.64 D in the matched eyes, p < 0.001). By UBM analysis, the anterior chamber depth (ACD) was shallower in MG than that in the matched eyes (2.34 ± 0.20 mm vs. 3.47 ± 0.29 mm, p < 0.001). The difference between the anterior vault distance of the pseudophakic eyes with MG and that of the matched eyes was also significant (p < 0.001). After treated with ZHV, the IOP was greatly decreased from 27.84 ± 10.14 mm Hg to 15.85 ± 4.41 mm Hg (p < 0.001). The refractive error also changed from -2.11 ± 0.91 D to +0.42 ± 0.99 D (p < 0.001). At the same time, the central ACD was significantly deepened from 2.30 ± 0.39 mm to 3.30 ± 0.31 mm (p < 0.001). CONCLUSION: Uncontrolled IOP and shallow anterior chamber both centrally and peripherally are the primary clinical characteristics for the pseudophakic eyes with MG. An unexpected refractive error or myopic shift for the eyes with PACG after cataract surgery can be an important hint for diagnosis of MG. The typical UBM image is an anterior displacement of the lens-iris diaphragm and a bow-shaped change of the intraocular lens. It is an effective way to treat pseudophakic MG with the ZHV through a peripheral iridectomy.


Asunto(s)
Catarata , Glaucoma de Ángulo Cerrado , Glaucoma , Miopía , Facoemulsificación , Humanos , Estudios Retrospectivos , Estudios de Casos y Controles , Glaucoma de Ángulo Cerrado/complicaciones , Glaucoma de Ángulo Cerrado/diagnóstico , Glaucoma de Ángulo Cerrado/cirugía , Glaucoma/cirugía , Presión Intraocular , Miopía/cirugía
10.
Vet Ophthalmol ; 26(5): 428-439, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36519702

RESUMEN

PURPOSE: Ophthalmic diagnosis in many avian species remains hindered by a lack of normative values. This study aimed to establish normal ophthalmic parameters for select diagnostic tests in clinically normal Quaker parrots. METHODS: Ninety-six captive Quaker parrots aged 8-18 years underwent ophthalmic examination to include assessment of neuro-ophthalmic reflexes, phenol red thread test, rebound tonometry, fluorescein staining, palpebral fissure length measurements, slit lamp biomicroscopy, indirect ophthalmoscopy, and ocular ultrasound biometry. RESULTS: Menace response, dazzle reflex, and direct pupillary light reflex were present for all Quaker parrots. Tear production (mean ± SD) was 13.3 ± 4.0 mm/15 s and intraocular pressure (IOP, mean ± SD) was 10.6 ± 1.4 and 6.0 ± 1.3 mmHg in the D and P rebound tonometer calibration settings, respectively. For IOP measurement, D and P calibration settings were not interchangeable, with the lesser variation of the D setting preferred in the absence of a gold standard. Ultrasound measurement of the anterior chamber depth increased with age and males had longer axial globe and vitreous lengths. Incidental adnexal and ocular lesions, identified in 36/96 (37.5%) of Quaker parrots, did not statistically affect the created reference data. CONCLUSIONS: This work provides reference values and clinical findings to assist with monitoring the health of wild populations and maintaining the health of captive Quaker parrots.


Asunto(s)
Oftalmopatías , Loros , Masculino , Animales , Oftalmopatías/diagnóstico , Oftalmopatías/veterinaria , Ojo/diagnóstico por imagen , Tonometría Ocular/veterinaria , Presión Intraocular
11.
Vet Ophthalmol ; 26(2): 176-179, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36152337

RESUMEN

An 8-year-old female pre-metamorphic axolotl (Ambystoma mexicanum) was examined for a suspected anterior lens luxation. Slit-lamp biomicroscopy revealed two lens-like structures in the anterior chamber of the right eye (OD), each with cataractous change. Ultrasound biomicroscopy and optical coherence tomography (OCT) were performed without sedation, and revealed small lenticular structures each with distinct nuclei and cortices. Although a distinct connection of the two lenticular structures could not be definitively ruled out, the structures appeared separate. Each of the lenticular structures was closely associated with its respective iris leaflet. This report demonstrates application of advanced imaging for diagnostic use in axolotl ophthalmology, showing that imaging of the lens can be performed without sedation, topical anesthetic, nor contact gel with high diagnostic quality. Although two distinct lenses were diagnosed with no historical evidence of trauma, the small sizes of each lenticular structure, with no detectable connection between them, are suggestive of a possible regenerative abnormality. This report opens discussion for the regenerative capabilities of the pre-metamorphic adult axolotl and possible implementations of their use in regenerative medicine research for the development of future therapies.


Asunto(s)
Cristalino , Lentes , Femenino , Animales , Ambystoma mexicanum , Microscopía Acústica/veterinaria , Tomografía de Coherencia Óptica/veterinaria
12.
Int Ophthalmol ; 43(12): 4821-4830, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37847477

RESUMEN

PURPOSE: To reveal refractive errors, the relationship between refractive errors and optical parameters, and the effect of prematurity and retinopathy of prematurity (ROP) on ocular development in school children with a history of prematurity. METHODS: Premature children aged 8-12 years were divided into 3 groups as those without ROP (Group 1), with ROP that did not require treatment (Group 2), and with laser-treated ROP (Group 3). Age-matched full-term healthy children were included in the control group. Demographic features were recorded. A detailed ophthalmologic examination was performed. Anterior chamber depth (ACD), trabecular-iris angle (TIA), iris thickness (IT), lens thickness (LT), vitreous body length (VBL), axial length (AL) were measured by ultrasound biomicroscopy (UBM). The results were compared between groups. RESULTS: Group 3 had the lowest best corrected visual acuity (0.81 ± 0.31 SL), the highest rates of myopia (55.9%) and astigmatism (50.0%). In the premature groups, ACD (p < 0.001), TIA (p < 0.001), IT (p = 0.016), VBL (p < 0.001) and AL (p < 0.001) were lower; LT (p < 0.001) was higher than in the control group. As birth weight (BW) and gestational age (GA) increased, ACD, TIA, VBL and AL increased, and LT decreased (p < 0.001). In the group 3, 35.2% anisometropia, 17.6% of esotropia and 5.9% of exotropia were detected. CONCLUSIONS: The frequency of myopia, astigmatism, hyperopia and anisometropia is increasing in premature children, especially in cases with laser-treated ROP. Premature cases are characterized by thicker lens, shallower ACD, narrower TIA and shorter AL. Refractive errors, anisometropia, amblyopia and strabismus are important causes of visual impairment in children with laser-treated ROP.


Asunto(s)
Anisometropía , Astigmatismo , Miopía , Errores de Refracción , Retinopatía de la Prematuridad , Recién Nacido , Niño , Humanos , Retinopatía de la Prematuridad/diagnóstico , Retinopatía de la Prematuridad/epidemiología , Turquía/epidemiología , Refracción Ocular , Errores de Refracción/epidemiología , Edad Gestacional , Miopía/diagnóstico , Biometría/métodos
13.
Vestn Oftalmol ; 139(2): 11-16, 2023.
Artículo en Ruso | MEDLINE | ID: mdl-37067927

RESUMEN

PURPOSE: This study analyzed cases with postoperative displacement of intraocular lens (IOL) relative to the haptic plane using ultrasound biomicroscopy (UBM). MATERIAL AND METHODS: The study analyzed biometry data of 231 patients (277 eyes) aged 72.39±7.77 years, among them 43.25% were males. IOL position and refraction were analyzed at 1, 3 and 6 months after standard phacoemulsification. RESULTS AND DISCUSSION: UBM was performed to analyze the position of the IOL. Stabilization of lens position was observed by the 3rd month of observation. Among the cases with displacement of the optical part relative to the haptic plane, the forward shift was determined in 24.85%, backward - in 16.67% of cases. Eyes with opposite IOL displacements differed significantly in lens diameter, ciliary sulcus diameter and the power of implanted IOL. IOL shift towards the retina produced significant hyperopic refractive error. A discriminant function was compiled using preoperative biometry data comprising the model for predicting backward IOL displacement with high probability. However, we failed to obtain a qualitative model for forward IOL displacements. CONCLUSION: Calculation error in modern formulas could occur because of IOL displacement, including the shift of the optical part relative to the haptic plane in postoperative period. Analysis of biometry data allows calculating IOL displacement towards the retina with a high probability, which could help avoid hyperopic refraction error postoperatively.


Asunto(s)
Hiperopía , Lentes Intraoculares , Facoemulsificación , Errores de Refracción , Masculino , Humanos , Femenino , Implantación de Lentes Intraoculares/métodos , Microscopía Acústica , Tecnología Háptica , Refracción Ocular , Facoemulsificación/efectos adversos , Biometría/métodos , Estudios Retrospectivos
14.
BMC Vet Res ; 18(1): 67, 2022 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-35144606

RESUMEN

BACKGROUND: Advances in MRI coil technology and increased availability of high-field MRI in veterinary medicine enable the acquisition of images of increasingly high spatial resolution while preserving signal-to-noise ratio.The purpose of the present study was to compare 3T high-resolution magnetic resonance imaging (HR-MRI) with ultrasound (US) and ultrasound biomicroscopy (UBM) in the normal canine eye, to assess its potential to depict normal ocular anatomy. RESULTS: HR-MRI was compared with US and UBM in 10 eyes from 10 healthy beagle dogs. Ocular structures (cornea, anterior chamber, iridocorneal angle, iris, lens, ciliary body, choroid, vitreous body, posterior wall of the eye, optic nerve and optic nerve sheath, extraocular muscles) were assessed subjectively and central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AQD), anteroposterior, mediolateral and dorsoventral lens diameter (APLD, MLLD, DVLD), anteroposterior diameter of the globe including and excluding the scleroretinal rim (APDSRR, APD), vitreous chamber depth (VCD) and optic nerve sheath diameter (ONSD) were measured in HR-MRI and in US. Optic nerve diameter (OND) was measured in HR-MRI. HR-MRI and UBM appearance of the anterior segment were subjectively compared. Detailed reference high-resolution MRI images of normal eyes of Beagle dogs are provided. CONCLUSIONS: HR-MRI allowed assessment of all structures identified with US and UBM. The MRI examinations were performed under general anesthesia with the addition of a neuromuscular blocking agent, while US and UBM examinations were performed in conscious animals. Visibility of the entire ocular wall, the lens, the structures caudal to the ciliary body and the optic nerve and its sheath was superior with HR-MRI. HR-MRI allowed the distinction of retina, choroid and sclera, and the delineation of structures not previously identified in canine eyes with MRI, including Tenon's capsule and the sub-Tenon's space.Plane selection was more accurate with HR-MRI compared to US. In general, the range of measurements was narrower for MRI than for US. CCT, AQD, APLD, MLLD, APD, APDSRR and ONSD differed significantly between HR-MRI and US, respectively (p = 0.005-0.027).Micro-MRI may be useful for the assessment of ocular pathologies in the future.


Asunto(s)
Segmento Anterior del Ojo , Microscopía Acústica , Animales , Segmento Anterior del Ojo/anatomía & histología , Segmento Anterior del Ojo/diagnóstico por imagen , Córnea/anatomía & histología , Perros , Imagen por Resonancia Magnética/veterinaria , Microscopía Acústica/métodos , Microscopía Acústica/veterinaria , Ultrasonografía/veterinaria
15.
BMC Ophthalmol ; 22(1): 330, 2022 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-35922842

RESUMEN

BACKGROUND: Addiction to Smartphone usage has psychological and physical impacts. However, the state of spasm of accommodation is unclear in Smartphone abusers. METHODS: We performed a cross-sectional study among adults aged 18-35 years between October 2016 and December 2018. Forty participants were Smartphone abusers according to the Smartphone addiction questionnaire, and 40 participants were non users. We measured auto refraction precycloplegia and postcycloplegia at far for all participants to evaluate the state of spasm of accommodation. We assessed the ultrasound biomicroscopy (UBM) parameters including anterior chamber angle (ACA). RESULTS: There was a significant difference in the odds of having spasm of accommodation between Smartphone abusers compared to non-users (OR = 6.64, 95% CI = 1.73-25.47; adjusted OR = 14.63, 95% CI = 2.99-71.62). The Smartphone abusers and non-users groups had a superior ACA median of 30.45° ± 8.3° vs. 26.75° ± 6.6° (P = 0.04) precycloplegia at far and 31.70° ± 11.8° vs. 31.45° ± 8.3° (P = 0.15) postcycloplegia at far, respectively, demonstrated by the Mann-Whitney U test. There was significant higher difference in the precycloplegic nasal ACA at far in the Smartphone abusers group than the non-users group (mean precycloplegic nasal ACA difference = 3.57°, 95% CI = 0.76° - 6.37°), demonstrated by the independent t test. Similarly, there was significant higher difference in the postcycloplegic nasal ACA at far (mean postcycloplegic nasal ACA difference = 4.26°, 95% CI = 1.33° - 7.19°). CONCLUSIONS: Smartphone abusers are in a condition of accommodation spasm. As a result, cycloplegic refraction should be done for Smartphone abusers.


Asunto(s)
Microscopía Acústica , Teléfono Inteligente , Acomodación Ocular , Adulto , Estudios Transversales , Humanos , Espasmo
16.
BMC Ophthalmol ; 22(1): 363, 2022 Sep 07.
Artículo en Inglés | MEDLINE | ID: mdl-36071422

RESUMEN

BACKGROUND: To evaluate a new method of implantable collamer lens (ICL) sizing based on ultrasound biomicroscopy (UBM) video clips. METHODS: This observational study included consecutive patients with myopia and myopic astigmatism scheduled for V4c toric ICL (TICL) implantation (STAAR) at Hangzhou MSK Eye Hospital (October 2020 to November 2020). Sulcus-to-sulcus (STS) distance, lens thickness (LT), and clinical refraction were measured preoperatively. The ZZ ICL formula (provides the predicted vault height and refraction based on TICL size, intraocular meridian, power, and eye parameters, including STS distance and LT) was used to select TICL size and predict vault height and residual refraction, which was also compared with the STAAR software recommended. Vault and residual refraction were measured at 3 months postoperatively. RESULTS: The analysis included 168 eyes in 84 patients. Postoperative vault size was comparable to that predicted by the ZZ ICL formula (528 ± 193 vs. 545 ± 156 µm, P = 0.227). Vault prediction error (PE) by the ZZ ICL formula was within 100, 300, and 500 µm in 40.48%, 88.10%, and 100% of eyes, respectively. Spherical equivalent (SE) and absolute cylindrical refractive error were 0.36 ± 0.48 and 0.40 ± 0.31 D at 3 months postoperatively. The SE PE, absolute cylindrical PE, and percentages of eyes with an absolute cylindrical PE within ± 0.50 D and ± 1.00 D were lower for the ZZ ICL formula than for the STAAR software (P < 0.01). CONCLUSIONS: Combining measurements obtained in UBM video clips with the ZZ ICL formula provides an effective method of sizing TICLs and predicting vault height and residual refractive error.


Asunto(s)
Lentes Intraoculares Fáquicas , Errores de Refracción , Humanos , Implantación de Lentes Intraoculares/métodos , Microscopía Acústica/métodos , Agudeza Visual
17.
Vet Ophthalmol ; 25 Suppl 1: 179-184, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-33694251

RESUMEN

OBJECTIVE: To describe the clinical use of ultrasound biomicroscopy (UBM) to evaluate equine corneal disease. METHODS: Images were obtained using a 50-MHz probe ultrasound biomicroscopy system (Quantel Aviso) and Clear Scan® probe cover. Six horses with corneal disease were evaluated via UBM for lesion size, lesion depth, and continuity of Descemet's membrane. Horses were sedated and received auriculopalpebral nerve blocks and application of topical anesthetic prior to UBM. RESULTS: Ultrasound biomicroscopy was easily performed in all cases. UBM evaluation of three cases of corneo-limbal squamous cell carcinoma yielded information regarding lesion depth for planning of keratectomies using fixed-depth keratomes and subsequent ß-radiation therapy. Corneal depth and continuity of Descemet's membrane were determined in two horses with stromal abscesses and allowed for planning of therapeutic options. In one horse with a corneal foreign body, UBM contributed to accurate assessment of the foreign body's stromal depth, which could not be assessed during ophthalmic examination due to extensive corneal cellular infiltrate. The information regarding corneal depth allowed for more accurate pre-surgical planning in patients with opaque corneal lesions. CONCLUSIONS: Ultrasound biomicroscopy was easily performed and provided useful information regarding lesion depth and continuity of Descemet's membrane for patients with corneo-limbal squamous cell carcinoma, stromal abscesses, and a corneal foreign body, allowing for increased precision in pre-surgical planning and development of therapeutic protocols.


Asunto(s)
Carcinoma de Células Escamosas , Enfermedades de la Córnea , Cuerpos Extraños , Enfermedades de los Caballos , Absceso/veterinaria , Animales , Carcinoma de Células Escamosas/veterinaria , Enfermedades de la Córnea/diagnóstico por imagen , Enfermedades de la Córnea/patología , Enfermedades de la Córnea/veterinaria , Cuerpos Extraños/veterinaria , Enfermedades de los Caballos/diagnóstico por imagen , Enfermedades de los Caballos/patología , Caballos , Microscopía Acústica/veterinaria , Ultrasonografía
18.
Vet Ophthalmol ; 25 Suppl 1: 103-110, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34784106

RESUMEN

OBJECTIVE: To compare the measurements of iridocorneal angle parameters between spectral domain optical coherence tomography (SD-OCT) and ultrasound biomicroscopy (UBM) in dogs. ANIMALS STUDIED AND PROCEDURES: A total of 47 eyes of dogs were scanned at the temporal limbus using SD-OCT and UBM. Iridocorneal angle (ICA) and angle opening distance (AOD) were measured from the obtained images accordingly. The intra-observer and inter-observer reproducibility were evaluated using the intraclass correlation coefficient. To evaluate intra-observer reproducibility, measurements of the first and second grading from the first examiner were compared. To evaluate inter-observer reproducibility, measurements between the two examiners were compared. Agreement between ICA and AOD for SD-OCT and UBM was evaluated using Bland-Altman plots. RESULTS: In the first grading, the mean ICA and AOD for SD-OCT were 31.4 ± 6.4° and 641.4 ± 270.8 µm, respectively. The mean ICA and AOD for UBM were 32.0 ± 4.8° and 700.4 ± 238.8 µm, respectively. For ICA and AOD measurements, intra-observer reproducibility was excellent for both devices, whereas inter-observer reproducibility was excellent for SD-OCT and good for UBM. The mean difference in ICA between SD-OCT and UBM was 0.6° with a limit of agreement (LoA) span of 18.9°. The mean difference in AOD between SD-OCT and UBM was 58.9 µm with a LoA span of 804.4 µm. CONCLUSIONS: Spectral domain optical coherence tomography is an effective non-contact imaging modality for the evaluation of canine iridocorneal angle parameters in a clinical setting. Reproducibility of measurements obtained is comparable or superior to UBM, but values obtained by SD-OCT and UBM for AOD are not interchangeable between devices.


Asunto(s)
Microscopía Acústica , Tomografía de Coherencia Óptica , Animales , Cámara Anterior/diagnóstico por imagen , Perros , Iris , Microscopía Acústica/métodos , Microscopía Acústica/veterinaria , Reproducibilidad de los Resultados , Tomografía de Coherencia Óptica/métodos , Tomografía de Coherencia Óptica/veterinaria
19.
J Clin Ultrasound ; 50(5): 685-693, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35474512

RESUMEN

Efficient ocular drug delivery is a challenging clinical problem with various therapeutic options but no clearly preferred methodology. Given the ubiquity of ultrasound as a diagnostic technique, the safety profile of ultrasound in an ocular context, and the prospect of custom-made ultrasound-sensitive contrast agents, ultrasound presents an attractive ocular drug delivery modality. In this review, we evaluate our present understanding of ultrasound as it relates to ocular drug delivery and significant knowledge gaps in the field. In doing so, we hope to call attention to a potentially novel drug delivery pathway that could be manipulated to treat or cure ocular diseases.


Asunto(s)
Medios de Contraste , Sistemas de Liberación de Medicamentos , Sistemas de Liberación de Medicamentos/métodos , Humanos , Preparaciones Farmacéuticas , Ultrasonografía/métodos
20.
Orbit ; 41(3): 335-340, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-33775197

RESUMEN

PURPOSE: To report the clinical features, ultrasound biomicroscopic features, and management outcome in patients presenting with thyroid eye disease (TED) and lower eyelid entropion. METHODS: Retrospective interventional case review of patients with TED presenting with lower eyelid entropion over a 12-year period. RESULTS: Five patients (eight eyes) of a total of 1211 presented with lower eyelid entropion as one of the presenting signs of TED (0.41%). The average age was 28.8 years (18-39 years), and three patients were males. Three had systemic hyperthyroidism, and two were euthyroid. Four (80%) had bilateral TED, three had inactive disease, and two were active. The average Hertel exophthalmometry reading was 24.6 mm. All patients had upper lid retraction. Four (80%) had concomitant lower eyelid retraction. Entropion was medial in five and complete in three eyes. Symptomatic corneal epitheliopathy was noted in four eyes. UBM was performed in four eyes which showed a thickened middle lamella. In four eyes (three patients), the entropion was managed conservatively as the patient was not contemplating surgery for proptosis. In the remaining four eyes (two patients) orbital decompression was performed and the lower eyelid retractor release corrected the symptomatic entropion. The average follow-up was 11.6 months (range 1-30). CONCLUSION: Lower eyelid entropion is a rare presenting sign in TED. The mechanism is multifactorial and could be caused by the thickened and fibrosed lower lid retractors, as demonstrated by UBM. Young age and globe projection may play a role. Decompression approaches that involve lower lid retractor release correct the entropion.


Asunto(s)
Entropión , Exoftalmia , Enfermedades de los Párpados , Oftalmopatía de Graves , Adulto , Entropión/etiología , Entropión/cirugía , Exoftalmia/cirugía , Enfermedades de los Párpados/complicaciones , Enfermedades de los Párpados/diagnóstico por imagen , Enfermedades de los Párpados/cirugía , Párpados/diagnóstico por imagen , Párpados/cirugía , Femenino , Oftalmopatía de Graves/complicaciones , Oftalmopatía de Graves/diagnóstico por imagen , Oftalmopatía de Graves/cirugía , Humanos , Masculino , Estudios Retrospectivos