RESUMEN
We have previously shown that recovery of visual responses to a deprived eye during the critical period in mouse primary visual cortex requires phosphorylation of the TrkB receptor for BDNF [M. Kaneko, J. L. Hanover, P. M. England, M. P. Stryker, Nat. Neurosci. 11, 497-504 (2008)]. We have now studied the temporal relationship between the production of mature BDNF and the recovery of visual responses under several different conditions. Visual cortical responses to an eye whose vision has been occluded for several days during the critical period and is then re-opened recover rapidly during binocular vision or much more slowly following reverse occlusion, when the previously intact fellow eye is occluded in a model of "patch therapy" for amblyopia. The time to recovery of visual responses differed by more than 18 h between these two procedures, but in each, the production of mature BDNF preceded the physiological recovery. These findings suggest that a spurt of BDNF production is permissive for the growth of connections serving the deprived eye to restore visual responses. Attenuation of recovery of deprived-eye responses by interference with TrkB receptor activation or reduction of BDNF production by interference with homeostatic synaptic scaling had effects consistent with this suggestion.
Asunto(s)
Ambliopía , Corteza Visual , Ratones , Animales , Factor Neurotrófico Derivado del Encéfalo/metabolismo , Receptor trkB/metabolismo , Corteza Visual/fisiología , Visión Ocular , Privación Sensorial/fisiología , Plasticidad Neuronal/fisiologíaRESUMEN
BACKGROUND: Amblyopia, the most common visual impairment of childhood, is a public health concern. An extended period of optical treatment before patching is recommended by the clinical guidelines of several countries. The aim of this study was to compare an intensive patching regimen, with and without extended optical treatment (EOT), in a randomised controlled trial. METHODS: EuPatch was a randomised controlled trial conducted in 30 hospitals in the UK, Greece, Austria, Germany, and Switzerland. Children aged 3-8 years with newly detected, untreated amblyopia (defined as an interocular difference ≥0·30 logarithm of the minimum angle of resolution [logMAR] best corrected visual acuity [BCVA]) due to anisometropia, strabismus, or both were eligible. Participants were randomly assigned (1:1) via a computer-generated sequence to either the EOT group (18 weeks of glasses use before patching) or to the early patching group (3 weeks of glasses use before patching), stratified for type and severity of amblyopia. All participants were initially prescribed an intensive patching regimen (10 h/day, 6 days per week), supplemented with motivational materials. The patching period was up to 24 weeks. Participants, parents or guardians, assessors, and the trial statistician were not masked to treatment allocation. The primary outcome was successful treatment (ie, ≤0·20 logMAR interocular difference in BCVA) after 12 weeks of patching. Two primary analyses were conducted: the main analysis included all participants, including those who dropped out, but excluded those who did not provide outcome data at week 12 and remained on the study; the other analysis imputed this missing data. All eligible and randomly assigned participants were assessed for adverse events. This study is registered with the International Standard Randomised Controlled Trial Number registry (ISRCTN51712593) and is no longer recruiting. FINDINGS: Between June 20, 2013, and March 12, 2020, after exclusion of eight participants found ineligible after detailed screening, we randomly assigned 334 participants (170 to the EOT group and 164 to the early patching group), including 188 (56%) boys, 146 (44%) girls, and two (1%) participants whose sex was not recorded. 317 participants (158 in the EOT group and 159 in the early patching group) were analysed for the primary outcome without imputation of missing data (median follow-up time 42 weeks [IQR 42] in the EOT group vs 27 weeks [27] in the early patching group). 24 (14%) of 170 participants in the EOT group and ten (6%) of 164 in the early patching group were excluded or dropped out of the study, mostly due to loss to follow-up and withdrawal of consent; ten (6%) in the EOT group and three (2%) in the early patching group missed the 12 week visit but remained on the study. A higher proportion of participants in the early patching group had successful treatment (107 [67%] of 159) than those in the EOT group (86 [54%] of 158; 13% difference; p=0·019) after 12 weeks of patching. No serious adverse events related to the interventions occurred. INTERPRETATION: The results from this trial indicate that early patching is more effective than EOT for the treatment of most children with amblyopia. Our findings also provide data for the personalisation of amblyopia treatments. FUNDING: Action Medical Research, NIHR Clinical Research Network, and Ulverscroft Foundation.
Asunto(s)
Ambliopía , Anteojos , Privación Sensorial , Agudeza Visual , Humanos , Ambliopía/terapia , Preescolar , Femenino , Masculino , Niño , Resultado del Tratamiento , Europa (Continente)RESUMEN
BACKGROUNDS: Unilateral high myopia (uHM), commonly observed in patients with retinal diseases or only with high myopia, is frequently associated with amblyopia with poor prognosis. This study aims to reveal the clinical and genetic spectrum of uHM in a large Chinese cohort. METHODS: A total of 75 probands with simplex uHM were included in our Pediatric and Genetic Eye Clinic. Patients with significant posterior anomalies other than myopic fundus changes were excluded. Variants were detected by exome sequencing and then analyzed through multiple-step bioinformatic and co-segregation analysis and finally confirmed by Sanger sequencing. Genetic findings were correlated with associated clinical data for analysis. RESULTS: Among the 75 probands with a mean age of 6.21 ± 4.70 years at the presentation, myopic fundus of C1 and C2 was observed in 73 (97.3%) probands. Surprisingly, specific peripheral changes were identified in 63 eyes involving 36 (48.0%) probands after extensive examination, including peripheral retinal avascular zone (74.6%, 47/63 eyes), neovascularization (54.0%), fluorescein leakage (31.7%), peripheral pigmentary changes (31.7%), and others. Exome sequencing identified 21 potential pathogenic variants of 13 genes in 20 of 75 (26.7%) probands, including genes for Stickler syndrome (COL11A1 and COL2A1; 6/20), FEVR (FZD4, LRP5, and TSPAN12; 5/20), and others (FBN1, GPR179, ZEB2, PAX6, GPR143, OPN1LW, FRMD7, and CACNA1F; 9/20). For the peripheral retinal changes in the 20 probands, variants in Stickler syndrome-related genes were predominantly associated with retinal pigmentary changes, lattice degeneration, and retinal avascular region, while variants in genes related to FEVR were mainly associated with the avascular zone, neovascularization, and fluorescein leakage. CONCLUSIONS: Genetic defects were identified in about one-fourth of simplex uHM patients in which significant consequences may be hidden under a classic myopic fundus in up to half. To our knowledge, this is the first systematic genetic study on simplex uHM to date. In addition to routine care of strabismus and amblyopia, careful examination of the peripheral retina and genetic screening is warranted for patients with uHM in order to identify signs of risk for retinal detachment and other complications and provide meaningful genetic counseling.
Asunto(s)
Ambliopía , Artritis , Enfermedades del Tejido Conjuntivo , Pérdida Auditiva Sensorineural , Miopía , Desprendimiento de Retina , Humanos , Niño , Lactante , Preescolar , Ambliopía/complicaciones , Mutación , Linaje , Miopía/genética , Fluoresceínas , Factores de Riesgo , Análisis Mutacional de ADN , Receptores Frizzled/genética , Proteínas del Citoesqueleto/genética , Proteínas de la Membrana/genética , Tetraspaninas/genéticaRESUMEN
Amblyopia is an abnormal visual processing-induced developmental disorder of the central nervous system that affects static and dynamic vision, as well as binocular visual function. Currently, changes in static vision in one eye are the gold standard for amblyopia diagnosis. However, there have been few comprehensive analyses of changes in dynamic vision, especially eye movement, among children with amblyopia. Here, we proposed an optimization scheme involving a video eye tracker combined with an "artificial eye" for comprehensive examination of eye movement in children with amblyopia; we sought to improve the diagnostic criteria for amblyopia and provide theoretical support for practical treatment. The resulting eye movement data were used to construct a deep learning approach for diagnostic and predictive applications. Through efforts to manage the uncooperativeness of children with strabismus who could not complete the eye movement assessment, this study quantitatively and objectively assessed the clinical implications of eye movement characteristics in children with amblyopia. Our results indicated that an amblyopic eye is always in a state of adjustment, and thus is not "lazy." Additionally, we found that the eye movement parameters of amblyopic eyes and eyes with normal vision are significantly different. Finally, we identified eye movement parameters that can be used to supplement and optimize the diagnostic criteria for amblyopia, providing a diagnostic basis for evaluation of binocular visual function.
Asunto(s)
Ambliopía , Estrabismo , Niño , Humanos , Ambliopía/diagnóstico , Ambliopía/terapia , Movimientos Oculares , Estrabismo/diagnóstico , Visión Binocular/fisiología , Sistema Nervioso CentralRESUMEN
PURPOSE OF REVIEW: Pediatric refractive surgery has been growing at a steady pace since its introduction in the early 1980âs. This article will review common laser refractive surgeries performed on pediatric patients along with controversies regarding the practice. RECENT FINDINGS: Pediatric refractive surgery is reserved for a small population of children who fail amblyopic treatment due to high anisometropic refractive errors. Publications over the years have treated these children with various types of laser refractive surgery. SUMMARY: Laser pediatric refractive surgery appears to be well tolerated and effective for the population of children that need it. It provides an alternative for anisometropic amblyopia treatment for children who would have otherwise not been able to improve their vision.
Asunto(s)
Ambliopía , Procedimientos Quirúrgicos Refractivos , Humanos , Niño , Ambliopía/cirugía , Procedimientos Quirúrgicos Refractivos/métodos , Oftalmología/tendencias , Preescolar , Errores de Refracción , Anisometropía/cirugíaRESUMEN
The purpose of the study was to determine the associations of self-perception, motor skills, and clinical features of young school-age children with glaucoma (CG). This is a cross-sectional observational study. Children from preschool to second grade, including CG (N = 19), children with amblyopia (CA, N = 28), and controls (N = 32), completed the Manual Dexterity and Aiming and Catching Scales of the Movement Assessment Battery for Children-2nd edition (MABC-2), including Manual Dexterity, Aiming and Catching, and Balance. CG, CA, and their parent completed the Pictorial Scale of Perceived Competence and Social Acceptance for Young Children, respectively, assessing the child's cognitive competence, peer acceptance, physical competence, and maternal acceptance. The Kruskal-Wallis H test and Bonferroni post hoc test compared motor skills among groups. Spearman's correlation analysis evaluated the correlations between motor skills, self-perception, and clinical features. The CG reported lower peer acceptance than CA (P = 0.040), and the parents of CG reported lower cognitive competence than CG reported (P = 0.046). Compared with controls, CG had worse performance of Aiming and Catching, and Balance (P = 0.018 and P = 0.001), and CA had worse performance of Balance (P = 0.009). The motor skills were comparable between CG and CA. For CG, older age correlated with worse competence of Aiming and Catching (r = - 0.620, P = 0.005), better best-corrected visual acuity of better-seeing eye correlated with higher competence of Manual Dexterity and Balance (r = - 0.494, P = 0.032, and r = - 0.516, P = 0.024), and longer duration of glaucoma correlated with worse competence of Manual Dexterity (r = - 0.487, P = 0.034). CONCLUSION: Glaucoma and amblyopia have significant negative impacts on children's daily motor skills. The acuity of a better-seeing eye is an important factor influencing motor movement. TRIAL REGISTRATION: ClinicalTrials.gov identifier, ChiCTR2100050415. WHAT IS KNOWN: ⢠The state of mental health in early childhood influences the development of their future personality and physical development. The prognosis and management of glaucoma may seriously impair the mental health development of the affected children. However, the exploration of psychological aspects and motor movement of childhood glaucoma was limited. WHAT IS NEW: ⢠Children with glaucoma have impaired motor skills and self-perception development, especially in terms of peer socialization.
Asunto(s)
Ambliopía , Glaucoma , Percepción de Movimiento , Niño , Humanos , Preescolar , Ambliopía/psicología , Estudios Transversales , Destreza Motora , Autoimagen , Glaucoma/diagnósticoRESUMEN
PURPOSE: To investigate the effects of Cambridge Stimulator with grating element stimulation on visual acuity (VA), grating acuity (GA), and contrast sensitivity (CS) in patients with amblyopia. METHODS: Three electronic databases (PubMed, Embase, and Cochrane Library) were searched for studies published from January 1970 to November 2022. The searched studies were reviewed and extracted independently by two authors. The included studies were evaluated by the Cochrane risk of bias. A meta-analysis calculating Hedges' g effect-size metric with 95% confidence intervals using random-effects DerSimonian-Laird model was employed. Heterogeneity was estimated using I2 statistics. Outcomes of interest included VA, GA, and CS. RESULTS: A total of 1221 studies were identified. Twenty-four studies including 900 subjects met the inclusion criteria. The outcome measure of all visual indexes (VA: Hedges' g of - 0.43, 95% CI = - 0.81 to - 0.05, I2 = 86%, p = 0.02; GA: Hedges' g of 3.79, 95% CI = 1.05 to 6.54, I2 = 98%, p = 0.01; CS: Hedges' g of 0.64, 95% CI = 0.19 to 1.09, I2 = 41%, p = 0.00) significantly favored in the grating group. CONCLUSIONS: Grating stimulation may be a positive help for visual functions in patients with amblyopia. The effects of grating stimulation on VA and CS appear to be opposite. This study is registered with www.crd.york.ac.uk/prospero/ (CRD42022366259).
Asunto(s)
Ambliopía , Humanos , Ambliopía/terapia , Agudeza Visual , Sensibilidad de Contraste , Bases de Datos FactualesRESUMEN
PURPOSE: The Amblyopia tracker app has been developed to be a tool for parents to monitor changes in vision at home during amblyopia treatment. The aims of this study were to evaluate the feasibility and repeatability of parents testing their children at home and to compare home test results to an assessment in clinic by an orthoptist. METHODS: Children (age < 18 years) with amblyopia (interocular acuity difference of ≥ 0.2logMAR) were recruited. Parents were asked to test their child with the app three times during a two week period followed by an online questionnaire about the usability. Participants also tested within 48 h of their appointment where the measurement was repeated by an orthoptist. RESULTS: Out of 277 potential participants contacted, 37 completed three home measurements, mean age 6.8 years (SD 2.94). Home tests comparisons were made between test two and three to ensure familiarity with the process. Paired t-tests showed no statistically significant difference for either eye or the interocular acuity difference (IAD). However, 29% had a difference in IAD of more than 0.1logMAR on repeated testing, with a maximum of 0.4logMAR difference in the IAD. Questionnaire responses from the parents who participated were predominantly positive with 97% of respondents saying they would use it if were available. Comparison of home and clinical measurements (n = 23, mean age 6.72 SD 2.60) showed no statistically significant differences for either eye or interocular acuity difference (paired t-test, p > 0.3 in all cases). CONCLUSION: Results show no statistically significant differences for the Amblyopia tracker app when used by parents at home on repeated testing, or between the home test by a parent and the test by a clinician. However, variability in the results does indicate that further improvements are required to ensure the results can be used as a reliable clinical tool.
Asunto(s)
Ambliopía , Aplicaciones Móviles , Agudeza Visual , Humanos , Ambliopía/diagnóstico , Ambliopía/fisiopatología , Niño , Masculino , Femenino , Agudeza Visual/fisiología , Encuestas y Cuestionarios , Reproducibilidad de los Resultados , Preescolar , Padres , Estudios de Factibilidad , Adolescente , Visión Binocular/fisiologíaRESUMEN
PURPOSE: To assess the possible benefits of the use of perceptual learning and dichoptic therapy combined with patching in children with amblyopia over the use of only patching. METHODS: Quasi-experimental multicentric study including 52 amblyopic children. Patients who improved their visual acuity (VA) by combining spectacles and patching were included in patching group (PG: 20 subjects), whereas those that did not improved with patching performed visual training (perceptual learning + dichoptic therapy) combined with patching, being assigned to the visual treatment group (VT: 32 subjects). Changes in VA, contrast sensitivity (CS), and stereopsis were monitored during a 6-month follow-up in each group. RESULTS: Significant improvements in VA were found in both groups at 1 month (p < 0.01). The total improvement of VA was 0.18 ± 0.16 and 0.31 ± 0.35 logMAR in PG and VT groups, respectively (p = 0.317). The Wilcoxon effect size was slightly higher in VT (0.48 vs. 0.54) at 6 months. An enhancement in CS was observed in the amblyopic eye of the VT group for all spatial frequencies at 1 month (p < 0.001). Likewise, the binocular function score also increased significantly in VT group (p = 0.002). A prediction equation of VA improvement at 1 month in VT group was obtained by multiple linear regression analysis (p < 0.001, R2 = 0.747). CONCLUSIONS: A combined treatment of visual training and patching is effective for obtaining a predictable improvement of VA, CS, and binocularity in patching-resistant amblyopic children.
Asunto(s)
Ambliopía , Privación Sensorial , Visión Binocular , Agudeza Visual , Humanos , Ambliopía/fisiopatología , Ambliopía/terapia , Agudeza Visual/fisiología , Estudios Prospectivos , Masculino , Femenino , Niño , Visión Binocular/fisiología , Estudios de Seguimiento , Preescolar , Resultado del Tratamiento , Anteojos , Sensibilidad de Contraste/fisiología , Percepción de Profundidad/fisiologíaRESUMEN
OBJECTIVE: To investigate the characteristics of eye movement in children with anisometropic amblyopia, and to compare those characteristics with eye movement in a control group. METHODS: 31 children in the anisometropic amblyopia group (31 amblyopic eyes in group A, 31 contralateral eyes in group B) and 24 children in the control group (48 eyes in group C). Group A was subdivided into groups Aa (severe amblyopia) and Ab (mild-moderate amblyopia). The overall age range was 6-12 years (mean, 7.83 ± 1.79 years). All children underwent ophthalmic examinations; eye movement parameters including saccade latency and amplitude were evaluated using an Eyelink1000 eye tracker. Data Viewer and MATLAB software were used for data analysis. RESULTS: Mean and maximum saccade latencies, as well as mean and maximum saccade amplitudes, were significantly greater in group A than in groups B and C before and after treatment (P < 0.05). Mean and maximum saccade latencies were significantly different among groups Aa, Ab, and C (P < 0.05). Pupil trajectories in two detection modes suggested that binocular fixation was better than monocular fixation. CONCLUSIONS: Eye movement parameters significantly differed between contralateral normal eyes and control eyes. Clinical evaluation of children with anisometropic amblyopia should not focus only on static visual acuity, but also on the assessment of eye movement.
Asunto(s)
Ambliopía , Visión Binocular , Agudeza Visual , Humanos , Ambliopía/fisiopatología , Niño , Masculino , Femenino , Agudeza Visual/fisiología , Visión Binocular/fisiología , Movimientos Sacádicos/fisiología , Movimientos Oculares/fisiología , Anisometropía/fisiopatología , Anisometropía/complicaciones , Fijación Ocular/fisiologíaRESUMEN
PURPOSE: The objective of this study was to evaluate the clinical efficacy of a 4D digital strabismus and amblyopia visual function correction system (4D-DSAAVFCS) in combination with conventional modalities compared with conventional modalities alone in children with anisometropic amblyopia. METHODS: This nonrandomized controlled study collected data on best-corrected visual acuity (BCVA), simultaneous vision, fusion vision, near stereoscopic vision, the amplitude of P100 wave (graphic evoked visual potentials), and the latency of P100 wave from both eyes at the beginning of the treatment and one year later. The MannâWhitney U test was used to compare BCVA contrasts in different subgroups, and the independent samples t test was used to compare the amplitude and latency of P100 wave contrasts in different subgroups. The basic cure rate, simultaneous vision recovery rate, fusion vision recovery rate, and near stereoscopic vision recovery rate contrasts in different subgroups were compared via the chi-square test. RESULTS: This study included 393 children (217 boys and 176 girls) aged 3 to 12 years with anisometropic amblyopia who were treated at the Aier Eye Hospital of Wuhan University from January 2020 to December 2022. The children were divided into two groups, the 4D group (263 cases) and the traditional group (130 cases), on the basis of the treatment modality. The children in the traditional group received treatment through the conventional method of occlusion and regular training. Meanwhile, the children in the 4D group received treatment through the traditional method and the 4D-DSAAVFCS. The 4D group was divided into two age groups: 3 ~ 6 years (161 cases) and 6 ~ 12 years (102 cases). The basic cure rate of the 4D group was significantly better than that of the traditional group (χ2 = 4.318, P < 0.05). There were no statistically significant differences in the BCVA, the latency of P100 wave, or the amplitude of P100 wave between the 4D group and the traditional group before treatment (U=-0.117, t=-0.05, all P > 0.05 ). After one year of treatment, a statistically significant difference was observed between the 4D group and the conventional group in terms of BCVA, the latency of P100 wave, and the amplitude of P100 wave (U=-1.243, t=-0.853, t=-1.546, all P < 0.05). These results suggest that the therapeutic effect was greater in the 4D group than in the conventional group. The recovery rates of simultaneous vision, convergent fusion, divergent fusion, and near stereoscopic vision were significantly greater in the 4D group than in the conventional group (χ2 = 4.344, 4.726, 5.123, and 2.036, respectively; all P < 0.05). Additionally, the basic cure rate of children aged 3 ~ 6 years in the 4D group was significantly greater than that of children aged 6 ~ 12 years (χ2 = 2.365, P < 0.05). In this study, BCVA was significantly lower in the 3 ~ 6-year-old group than in the 6 ~ 12-year-old group (U = -1.267, P < 0.05). Similarly, the amplitude of P100 wave was also significantly greater in the 3 ~ 6-year-old group than in the 6 ~ 12-year-old group (t = -1877, P < 0.05). The latency of P100 wave was lower in the 3 ~ 6-year-old group than in the 6 ~ 12-year-old group (t=-0.998, P < 0.05). Additionally, the recovery rate of near stereoscopic vision was significantly greater in the 3 ~ 6-year-old group than in the 6 ~ 12-year-old group (χ2 = 4.534, P < 0.05). CONCLUSION: The combination of the traditional method with the 4D-DSAAVFCS was more effective than the traditional method alone in treating amblyopic children. This approach was particularly helpful in improving the visual acuity of the children and restoring their optic nerve conduction function, simultaneous vision, fusion vision, and near stereoscopic vision. The combination of the traditional method and the 4D-DSAAVFCS is more effective for younger children.
Asunto(s)
Ambliopía , Estrabismo , Agudeza Visual , Humanos , Ambliopía/terapia , Ambliopía/fisiopatología , Femenino , Masculino , Agudeza Visual/fisiología , Niño , Preescolar , Estrabismo/fisiopatología , Estrabismo/terapia , Anteojos , Resultado del Tratamiento , Visión Binocular/fisiología , Estudios de Seguimiento , Potenciales Evocados Visuales/fisiologíaRESUMEN
BACKGROUND: Functional visual impairments in children are primarily caused by amblyopia or strabismus. This study aimed to determine the prevalence and clinical profile of amblyopia and strabismus among individuals aged 3-16 years in Shanghai, China. METHODS: From February 2023 to February 2024, this hospital-based, cross-sectional study included data of children who visited the Ophthalmology Department of Shanghai General Hospital. Comprehensive ocular examinations included visual acuity measurement after cycloplegic refraction, slit lamp examination, cover test, and dilated fundus examination. Descriptive statistics were performed to estimate the proportion and clinical characteristics of amblyopia and strabismus. RESULTS: A total of 920 children were enrolled in our study. Among them, 223 (24.24%) children were identified as amblyopia. Unilateral amblyopia occupied 57.85%, and bilateral amblyopia occupied 42.15%. Most participants were within the age range of 5-10 years (75.97% for unilateral amblyopia, and 70.21% for bilateral amblyopia). Anisometropia was the primary cause of unilateral amblyopia (68.99%). Most amblyopic children have high hyperopia (38.76% for unilateral amblyopia, and 39.89% for bilateral amblyopia). 30 (3.26%) children were diagnosed with strabismus, and 19 (63.3%) of them were aged 5-10 years. Seven of the children had both strabismus and amblyopia. CONCLUSION: The proportion of patients with amblyopia and strabismus was determined as 24.24% and 3.26% in our study. Anisometropia was the leading cause of unilateral amblyopia, whereas high hyperopia was a crucial refractive error in the amblyopic population. These findings shed light on further longitudinal studies targeting the age-related changes in amblyopia, strabismus and refraction errors. Therefore, efforts should be made to manage uncorrected refractive errors, amblyopia, and strabismus among children in Shanghai.
Asunto(s)
Ambliopía , Errores de Refracción , Estrabismo , Agudeza Visual , Humanos , Ambliopía/epidemiología , Ambliopía/fisiopatología , Ambliopía/diagnóstico , China/epidemiología , Prevalencia , Estudios Transversales , Niño , Preescolar , Adolescente , Femenino , Masculino , Estrabismo/epidemiología , Estrabismo/fisiopatología , Errores de Refracción/epidemiología , Errores de Refracción/fisiopatología , Agudeza Visual/fisiología , Distribución por Edad , Refracción Ocular/fisiologíaRESUMEN
BACKGROUND: The long-term visual outcomes in spasmus nutans patients is largely unknown. The purpose of this study was to characterize visual outcomes and identify comorbid ophthalmic conditions in patients with spasmus nutans. METHODS: We retrospectively reviewed the charts of consecutive patients diagnosed with spasmus nutans between 2000 and 2020. Demographic information, ophthalmic characteristics, and neuroimaging results were assessed over time. RESULTS: Of the 32 patients included in the study, 13 (41%) were female. Underlying medical conditions included a diagnosis of Trisomy 21 in 6 (19%) and prematurity in 8 (25%). Twenty-one patients (66%) self-reported as a race other than Caucasian. 18 patients (56%) had non-private health insurance and 1 (3%) was uninsured. Mean age at diagnosis and resolution were 16 months (range 45 months) and 48 months (range 114 months), respectively. All 32 patients had nystagmus, 31 (97%) had head nodding and 16 (50%) had ocular torticollis. Mean follow-up was 66 months (range 185 months). On initial presentation, 6/32 (19%) had an amblyogenic refractive error and mean best-corrected visual acuity (BCVA) in the better-seeing eye was 0.78 Logarithm of the Minimum Angle of Resolution (LogMAR) (range 1.24). In a sub-analysis that included patients with > 1 exam (n = 23), 17/20 (85%) had an amblyogenic refractive error and mean BCVA in the better-seeing eye was 0.48 LogMAR (range 1.70). At the final exam, 12 patients had measurable stereopsis, eight had strabismus, and three had undergone strabismus surgery. Eight patients required treatment for amblyopia. CONCLUSIONS: We found a high prevalence of amblyogenic refractive error, strabismus and amblyopia among patients with spasmus nutans. Children with spasmus nutans benefit from ongoing ophthalmic follow-up until they are past the amblyopic age range, even after resolution of nystagmus.
Asunto(s)
Agudeza Visual , Humanos , Femenino , Masculino , Estudios Retrospectivos , Agudeza Visual/fisiología , Preescolar , Niño , Lactante , Estudios de Seguimiento , Nistagmo Patológico/fisiopatología , Ambliopía/fisiopatología , Ambliopía/epidemiología , Estrabismo/fisiopatologíaRESUMEN
BACKGROUND AND AIM: Refractive errors, amblyopia, strabismus, and low vision are more common among children with hearing impairments in comparison with their hearing peers. Neglecting visual disorders can pose educational and social problems for these children. The present study aimed to assess the prevalence of refractive errors, amblyopia, strabismus, and low vision among hearing-impaired and deaf students in Kermanshah. MATERIALS AND METHODS: A total of 79 deaf and hearing impaired students within the age range of 7-20 years (mean age of 15.01 ± 2.72) underwent optometric examinations, including autorefractometry, retinoscopy, ophthalmoscopy, slit lamp, visual acuity measurement, and cover-uncover test. Those who needed further evaluation were referred to the Ophthalmology Clinic of Imam Khomeini Hospital. RESULTS: Regarding the prevalence of refractive errors, 32 (40.5%) subjects had one or a combination of refractive errors, the most common of which was astigmatism (36.7%), followed by amblyopia (15.1%). The most common type of strabismus was latent strabismus (heterophoria) (88.6%), followed by exophoria (81%). Moreover, 3 (3.7%) cases had nystagmus. A significant difference was observed between the prevalence of amblyopia and the degree of hearing loss (P = 0.026), and no significant difference was detected in other cases. CONCLUSION: As evidenced by the obtained results, refractive errors, amblyopia, strabismus, and low vision are more prevalent among deaf and hearing-impaired children compared to normal children because deaf and hearing-impaired children are not able to convey their vision problems and need to compensate for their poor hearing with an enhanced sense of sight, inattention to these disorders can present these children with serious educational and social problems. Therefore, eye screening examinations are of paramount importance in deaf and hearing-impaired children.
Asunto(s)
Ambliopía , Errores de Refracción , Estrabismo , Baja Visión , Agudeza Visual , Humanos , Estrabismo/epidemiología , Estrabismo/fisiopatología , Niño , Adolescente , Masculino , Femenino , Errores de Refracción/epidemiología , Errores de Refracción/fisiopatología , Errores de Refracción/complicaciones , Baja Visión/epidemiología , Ambliopía/epidemiología , Ambliopía/fisiopatología , Ambliopía/diagnóstico , Prevalencia , Adulto Joven , Agudeza Visual/fisiología , Irán/epidemiología , Estudios Transversales , Personas con Deficiencia Auditiva , Sordera/epidemiología , EstudiantesRESUMEN
SIGNIFICANCE: Results of this study provide preliminary data on parent strategies for improving compliance with eyeglass treatment in young children, an age group for which previous data are limited. Parent responses provide important insights to support parents of young children who wear eyeglasses and provide preliminary data to guide additional research. PURPOSE: The goal of this exploratory study was to learn more about parents' strategies to improve compliance with eyeglass treatment of young children. METHODS: An online survey of parents of 1-year-old to less than 5-year-old children who wear eyeglasses was conducted. Parents indicated whether they used various strategies to encourage wear and were asked to provide advice for parents of young children recently prescribed eyeglasses. Use of various strategies by age was determined. Open-ended responses regarding advice for other parents were analyzed using qualitative content analysis. RESULTS: The final sample included 104 parents who were predominantly White (81%), non-Hispanic (76%), and college graduates (68%). During the 2 weeks prior to survey completion, 74% of parents reported their child wore their eyeglasses ≥8 hours/day. Use of strategies for improving eyeglass wear varied by child age. The most frequent recommendations that parents provided for other parents were to be consistent in encouraging wear, use social modeling, provide positive reinforcement when the eyeglasses are worn, and ensure that the eyeglasses fit well and were comfortable. CONCLUSIONS: Parents provided many useful insights into their experiences. However, results may not be broadly generalizable, because of the limited diversity and high rate of compliance in the study sample. Further research with more diverse populations and research on effectiveness of various strategies to increase compliance in this age group are recommended to support eyeglass treatment compliance in young children.
Asunto(s)
Anteojos , Padres , Cooperación del Paciente , Humanos , Preescolar , Femenino , Masculino , Lactante , Encuestas y Cuestionarios , Ambliopía/terapia , Ambliopía/fisiopatología , AdultoRESUMEN
PURPOSE: To investigate the feasibility of children measuring their own contrast sensitivity using a range of tablet- and paper-based tests. METHODS: Forty children aged 5-15 years with amblyopia (N = 10), bilateral vision impairment (N = 10) or good vision (N = 20) measured their own vision on a screen-based optotype test (Manifold), a gamified vision test (PopCSF) and a paper-based test (Spotchecks) in a laboratory with minimal supervision. Completion rate, test-retest repeatability, test duration and participants' preferences were recorded for each test. RESULTS: Most participants (36/40) were able to perform all three tests. All tests were correlated with clinically measured visual acuity and contrast sensitivity (p < 0.001). The 95% coefficient of repeatability was 0.30 dB for Manifold, 0.29 dB for PopCSF and 0.13 dB for Spotchecks. All tests differentiated between children with reduced contrast sensitivity and control participants. PopCSF and Spotchecks were also able to differentiate between children with amblyopia and those with good vision. Median test time was 152, 130 and 202 s for Manifold, PopCSF and Spotchecks, respectively. Twenty-two participants preferred the PopCSF test, 10 preferred Spotchecks and 6 preferred Manifold. Thirty-nine out of the 40 children (98%) said they would measure their own vision at home using at least one of these tests every month. CONCLUSIONS: Children and young people can test their own contrast sensitivity with repeatable results. Of these three tests, the most repeatable was Spotchecks, the quickest was PopCSF and participants' favourite was PopCSF. Nearly all of the participants said they would be willing to use at least one of the three tests at home.
Asunto(s)
Ambliopía , Niño , Humanos , Adolescente , Ambliopía/diagnóstico , Sensibilidad de Contraste , Pruebas de Visión , Visión Ocular , Agudeza VisualRESUMEN
PURPOSE: The improvement in visual acuity (VA) was determined during optical treatment in children with amblyopia before their participation in a randomised clinical trial comparing the effect of dichoptic video gaming using virtual reality goggles with occlusion therapy. METHODS: Children aged 4-12 years with an interocular VA difference ≥0.20 logMAR and an amblyogenic factor: strabismus <30Δ, ≥1.00 D anisometropia, astigmatism ≥1.50 D and/or hypermetropia ≥1.50 D were eligible for 16 weeks of optical treatment. Children with previous amblyopia treatment were excluded. Compliance with spectacle wear was measured electronically over 1 week using the occlusion dose monitor (ODM). The reliability of these measurements was verified. The main outcome was an increase in amblyopic eye VA from baseline to 16 weeks. RESULTS: Sixty-five children entered the optical treatment period. Mean age was 6.0 ± 2.2 years (range: 4-12 years; IQR 4.5-6.7 years). Amblyopia was caused by anisometropia in 53 (82%) children, strabismus in 6 (9%) and combined mechanism in 6 (9%). After optical treatment, mean VA improved by 0.20 logMAR (SD 0.28; p < 0.001) and 0.07 in the amblyopic and fellow eye, respectively (SD 0.20; p = 0.03). This resulted in 24 children (37%) with an interocular VA difference <0.20 logMAR and in 17% of children with VA at the start of 0.30 logMAR or worse. Poor VA in the amblyopic eye at baseline (p = 0.001) and high anisometropia (p = 0.001) were associated with VA improvement. On average, spectacles were worn 9.7 ± 2.4 h/day (range: 2.3-13.6 h); mean compliance was 73% ± 18% of estimated wake time. Only ambient temperature ≥ 31°C or when spectacles were worn on top of the head prevented a reliable ODM measurement. CONCLUSIONS: VA improved by two lines resulting in more than a third of the children being treated sufficiently with spectacles alone and no longer being classified as amblyopic. The ODM proved to be a reliable method of measuring compliance with spectacle wear.
Asunto(s)
Ambliopía , Anteojos , Cooperación del Paciente , Agudeza Visual , Niño , Preescolar , Femenino , Humanos , Masculino , Ambliopía/terapia , Ambliopía/fisiopatología , Cooperación del Paciente/estadística & datos numéricos , Reproducibilidad de los Resultados , Privación Sensorial , Resultado del Tratamiento , Juegos de Video , Visión Binocular/fisiología , Agudeza Visual/fisiologíaRESUMEN
INTRODUCTION: This study aimed to explore the functional connectivity of the primary visual cortex (V1) in children with anisometropic amblyopia by using the resting-state functional connectivity analysis method and determine whether anisometropic amblyopia is associated with changes in brain function. METHODS: Functional magnetic resonance imaging (fMRI) data were obtained from 16 children with anisometropia amblyopia (CAA group) and 12 healthy children (HC group) during the resting state. The Brodmann area 17 (BA17) was used as the region of interest, and the functional connection (FC) of V1 was analyzed in both groups. A two-sample t test was used to analyze the FC value between the two groups. Pearson's correlation was used to analyze the correlation between the mean FC value in the brain function change area of the CAA group and the best corrected visual acuity (BCVA) of amblyopia. p < 0.05 was considered statistically significant. RESULTS: There were no significant differences in age and sex between the CAA and HC groups (p > 0.05). Compared to the HC group, the CAA group showed lower FC values in BA17 and the left medial frontal gyrus, as well as BA17 and the left triangle inferior frontal gyrus. Conversely, the CAA group showed higher FC values in BA17 and the left central posterior gyrus. Notably, BCVA in amblyopia did not correlate with the area of change in mean FC in the brain function of the CAA group. CONCLUSION: Resting-state fMRI-based functional connectivity analysis indicates a significant alteration in V1 of children with anisometropic amblyopia. These findings contribute additional insights into the neuropathological mechanisms underlying visual impairment in anisometropic amblyopia.
Asunto(s)
Ambliopía , Imagen por Resonancia Magnética , Corteza Visual Primaria , Agudeza Visual , Humanos , Ambliopía/fisiopatología , Femenino , Masculino , Niño , Agudeza Visual/fisiología , Corteza Visual Primaria/fisiopatología , Anisometropía/fisiopatología , Mapeo Encefálico/métodos , Descanso/fisiología , Corteza Visual/fisiopatología , Corteza Visual/diagnóstico por imagenRESUMEN
BACKGROUND: We queried ChatGPT (OpenAI) and Google Assistant about amblyopia and compared their answers with the keywords found on the American Association for Pediatric Ophthalmology and Strabismus (AAPOS) website, specifically the section on amblyopia. Out of the 26 keywords chosen from the website, ChatGPT included 11 (42%) in its responses, while Google included 8 (31%). OBJECTIVE: Our study investigated the adherence of ChatGPT-3.5 and Google Assistant to the guidelines of the AAPOS for patient education on amblyopia. METHODS: ChatGPT-3.5 was used. The four questions taken from the AAPOS website, specifically its glossary section for amblyopia, are as follows: (1) What is amblyopia? (2) What causes amblyopia? (3) How is amblyopia treated? (4) What happens if amblyopia is untreated? Approved and selected by ophthalmologists (GW and DL), the keywords from AAPOS were words or phrases that deemed significant for the education of patients with amblyopia. The "Flesch-Kincaid Grade Level" formula, approved by the US Department of Education, was used to evaluate the reading comprehension level for the responses from ChatGPT, Google Assistant, and AAPOS. RESULTS: In their responses, ChatGPT did not mention the term "ophthalmologist," whereas Google Assistant and AAPOS both mentioned the term once and twice, respectively. ChatGPT did, however, use the term "eye doctors" once. According to the Flesch-Kincaid test, the average reading level of AAPOS was 11.4 (SD 2.1; the lowest level) while that of Google was 13.1 (SD 4.8; the highest required reading level), also showing the greatest variation in grade level in its responses. ChatGPT's answers, on average, scored 12.4 (SD 1.1) grade level. They were all similar in terms of difficulty level in reading. For the keywords, out of the 4 responses, ChatGPT used 42% (11/26) of the keywords, whereas Google Assistant used 31% (8/26). CONCLUSIONS: ChatGPT trains on texts and phrases and generates new sentences, while Google Assistant automatically copies website links. As ophthalmologists, we should consider including "see an ophthalmologist" on our websites and journals. While ChatGPT is here to stay, we, as physicians, need to monitor its answers.
Asunto(s)
Ambliopía , Internet , Educación del Paciente como Asunto , Ambliopía/terapia , Humanos , Educación del Paciente como Asunto/métodos , Oftalmología/educaciónRESUMEN
In binocular vision, the relative strength of the input from the two eyes can have significant functional impact. These inputs are typically balanced; however, in some conditions (e.g., amblyopia), one eye will dominate over the other. To quantify imbalances in binocular vision, we have developed the Dichoptic Contrast Ordering Test (DiCOT). Implemented on a tablet device, the program uses rankings of perceived contrast (of dichoptically presented stimuli) to find a scaling factor that balances the two eyes. We measured how physical interventions (applied to one eye) affect the DiCOT measurements, including neutral density (ND) filters, Bangerter filters, and optical blur introduced by a +3-diopter (D) lens. The DiCOT results were compared to those from the Dichoptic Letter Test (DLT). Both the DiCOT and the DLT showed excellent test-retest reliability; however, the magnitude of the imbalances introduced by the interventions was greater in the DLT. To find consistency between the methods, rescaling the DiCOT results from individual conditions gave good results. However, the adjustments required for the +3-D lens condition were quite different from those for the ND and Bangerter filters. Our results indicate that the DiCOT and DLT measures partially separate aspects of binocular imbalance. This supports the simultaneous use of both measures in future studies.