1.
Ann Pharm Fr ; 82(4): 706-717, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38447875

RESUMEN

INTRODUCTION: In anesthesia, a medication error would occur every 20 to 133 anesthesia procedures, and 14% is related to a route administration error. To secure neuraxial route, ISO group published a norm in 2016 to develop specific connectors, the "NRFit® connector". The main objective of this work, is to develop a risk mapping related to neuraxial medication errors therefore prepare the NRFit® implementation in anesthesia units in a French Universitary Hospital. METHODS: Failure modes, effects and criticality analysis (FMECA) methodology was used for our risk mapping which was divided in 3 anesthesia specialities. For each, the analysis was performed for accidental neuraxial administration of intravenous drugs, and its opposite error. Secondly, NRFit® devices were tested for 1 month by 3 experimented anesthetists. RESULTS: The majority of reported errors concerns epidural and intrathecal anesthesia, and more frequently in the field of obstetrics. Opioids and tranexamic acid, administered in neuraxial route, are drugs with the highest criticality. The tests were rather conclusive and made it possible to highlight the additional needs in medical devices. DISCUSSION: Obstetrics is the riskiest area due to the frequency of epidural anesthesia, the administration of critical drugs in intravenous and neuraxial route. This work increased the awareness of our group, improved the measure of this risk and harmonized practices. CONCLUSION: This work is the first step of the project to prevent administration route error in anesthesia during patient's drug management. The next step will be the NRFit® implementation for epidural and combined spinal-epidural anesthesia in our hospital.


Asunto(s)
Errores de Medicación , Humanos , Errores de Medicación/prevención & control , Anestesia Epidural/instrumentación , Anestesia Raquidea/instrumentación , Francia , Anestésicos/administración & dosificación , Medición de Riesgo , Anestesia Obstétrica/instrumentación , Anestesia , Femenino
2.
Anesth Analg ; 134(2): 400-409, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34724678

RESUMEN

BACKGROUND: Traditional landmark-guided spinal anesthesia can be challenging in elderly patients with hip fractures. Ultrasound assistance (USAS) and real-time ultrasound guidance (USRTG) techniques can facilitate lumbar neuraxial blocks. However, it remains undetermined which method is optimal for use in elderly patients. This study aimed to evaluate which technique was associated with a higher success rate of spinal anesthesia in elderly patients with hip fractures: USAS or USRTG technique. METHODS: A total of 114 elderly patients (≥70 years of age) with hip fractures were randomly assigned to receive spinal anesthesia using either the USAS or USRTG technique. The primary outcome was the first-attempt success rate, analyzed using the χ2 test. Secondary outcomes included first-pass success rate, the number of needle attempts and passes, locating time, procedure time, total time, adverse reactions and complications, patient satisfaction, and procedural difficulty score. RESULTS: The first-attempt success rate (80.7% vs 52.6%; 95% confidence interval [CI], for the difference, 11.6-44.6) and first-pass success rate (63.2% vs 31.6%; 95% CI for the difference, 14.2-49) were both significantly higher in the USAS compared with the USRTG group (both P = .001). The number of attempts (1 [1-1] vs 1 [1-3]; P = .001) and median passes (1 vs 3; P < .001) were both significantly lower in the USAS group than in the USRTG group. The USRTG group had a shorter locating time (175 seconds [129-234 seconds] vs 315 seconds [250-390 seconds]; P < .001) but a longer procedure time (488 seconds [260-972 seconds] vs 200 seconds [127-328 seconds]; P < .001) and total time (694 seconds [421-1133 seconds] vs 540 seconds [432-641 seconds]; P = .036). There were no significant differences between the 2 groups with regard to the adverse reactions and complications. More patients in the USAS group had a high satisfaction score of 3 to 5 (P = .008). Overall, anesthesiologists rated the USRTG group procedure as "more difficult" (P = .008). CONCLUSIONS: In elderly patients with hip fractures, spinal anesthesia with the USRTG technique is not superior to the USAS technique since it has a lower success rate, longer procedure time, lower satisfaction score, and is more difficult to perform. So USAS technique may be more suitable for elderly patients.


Asunto(s)
Anestesia Raquidea/métodos , Sistemas de Computación , Fracturas de Cadera/diagnóstico por imagen , Fracturas de Cadera/cirugía , Monitoreo Intraoperatorio/métodos , Ultrasonografía Intervencional/métodos , Anciano , Anciano de 80 o más Años , Anestesia Raquidea/instrumentación , Femenino , Humanos , Masculino , Monitoreo Intraoperatorio/instrumentación , Ultrasonografía Intervencional/instrumentación
3.
Anaesthesia ; 76(8): 1098-1110, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33332606

RESUMEN

Post-dural puncture headache is one of the most undesirable complications of spinal anaesthesia. Previous pairwise meta-analyses have either compared groups of needles or ranked individual needles based on the pooled incidence of post-dural puncture headache. These analyses have suggested both the gauge and needle tip design as risk-factors, but failed to provide an unbiased comparison of individual needles. This network meta-analysis compared the odds of post-dural puncture headache with needles of varying gauge and tip design. We searched randomised controlled trials in medical databases. The primary outcome measure of the network meta-analysis was the incidence of post-dural puncture headache. Secondary outcomes were procedural failure, backache and non-specific headache. Overall, we compared 11 different needles in 61 randomised controlled trials including a total of 14,961 participants. The probability of post-dural puncture headache and procedural failure was lowest with 26-G atraumatic needles. The 29-G cutting needle was more likely than three atraumatic needles to have the lowest odds of post-dural puncture headache, although with increased risk of procedural failure. The probability rankings were: 26 atraumatic > 27 atraumatic > 29 cutting > 24 atraumatic > 22 atraumatic > 25 atraumatic > 23 cutting > 22 cutting > 25 cutting > 27 cutting = 26 cutting for post-dural puncture headache; and 26 atraumatic > 25 cutting > 22 cutting > 24 atraumatic > 22 atraumatic > 25 atraumatic > 26 cutting > 29 cutting > 27 atraumatic = 27 cutting for procedural success. Meta-regression by type of surgical population (obstetric/non-obstetric) and participant position (sitting/lateral) did not alter these rank orders. This analysis provides an unbiased comparison of individual needles that does not support the use of simple rules when selecting the optimal needle. The 26-G atraumatic needle is most likely to enable successful insertion while avoiding post-dural puncture headache but, where this is not available, our probability rankings can help clinicians select the best of available options.


Asunto(s)
Anestesia Raquidea/efectos adversos , Anestesia Raquidea/instrumentación , Cefalea Pospunción de la Duramadre/epidemiología , Anestesia Raquidea/métodos , Humanos , Agujas/efectos adversos
4.
BMC Anesthesiol ; 20(1): 32, 2020 01 30.
Artículo en Inglés | MEDLINE | ID: mdl-32000680

RESUMEN

BACKGROUND: Performing spinal anaesthesia using the conventional popping method with a 27-gauge (27G) spinal needle is technically difficult. In this study, we compared the aspiration and conventional popping method for spinal anaesthesia using 27G Quincke-type needles. METHODS: This prospective, randomized study enrolled 90 patients, aged 19 to 65 years, with American Society of Anesthesiologists physical status I-III, who were undergoing spinal anaesthesia. Patients were randomly assigned to one of two groups using a computer-generated random number table: patients receiving spinal anaesthesia using the aspiration method, in which the needle is advanced with continuous aspiration, or the conventional popping method. The primary outcome measure was the success rate of the first attempt to perform dural puncture. Number of attempts and passages, withdrawal cases, successful attempt time, total procedure time, and actual depth of dural puncture were recorded. RESULTS: Eighty-eight patients were included in the study. In the aspiration group, the success rate of first attempt for dural puncture was 93.3%, compared with 72.1% in the popping group (P = 0.019). Success involving needle withdrawal was recorded in 4 (8.9%) patients in the aspiration group and 13 (30.2%) in the popping group (P = 0.024). In the popping group, the number of attempts was significantly higher (P = 0.044), and total procedure time was significantly longer (P = 0.023). Actual depths of dural puncture were deeper in the popping group than in the aspiration group (P = 0.019). CONCLUSIONS: The aspiration method using a 27G Quincke-type needle offers clinical benefits for dural puncture compared with the conventional popping method for spinal anaesthesia. TRIAL REGISTRATION: Clinical research information service number: KCT0002815, registered 21/Apr/2018. Retrospectively registered.


Asunto(s)
Anestesia Raquidea/instrumentación , Anestesia Raquidea/métodos , Punción Espinal/instrumentación , Punción Espinal/métodos , Adulto , Anciano , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Agujas , Estudios Prospectivos , Adulto Joven
5.
Anesth Analg ; 128(5): 999-1004, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30286007

RESUMEN

BACKGROUND: Physician educators must balance the need for resident procedural education with clinical time pressures as well as patient safety and comfort. Alternative educational strategies, including e-learning tools, may be beneficial to orient novice learners to new procedures and speed proficiency. We created an e-learning tool (computer-enhanced visual learning [CEVL] neuraxial) to enhance trainee proficiency in combined spinal-epidural catheter placement in obstetric patients and performed a randomized controlled 2-center trial to test the hypothesis that use of the tool improved the initial procedure performed by the anesthesiology residents. METHODS: Anesthesiology residents completing their first obstetric anesthesiology rotation were randomized to receive online access to the neuraxial module (CEVL group) or no access (control) 2 weeks before the rotation. On the first day of the rotation, residents completed a neuraxial procedure self-confidence scale and an open-ended medical knowledge test. Blinded raters observed residents performing combined spinal-epidural catheter techniques in laboring parturients using a procedural checklist (0-49 pts); the time required to perform the procedure was recorded. The primary outcome was the duration of the procedure. RESULTS: The CEVL group had significantly shorter mean (±standard deviation) procedure time compared to the control group 22.5 ± 4.9 vs 39.5 ± 7.1 minutes (P < .001) and had higher scores on the overall performance checklist 36.4 ± 6.6 vs 28.8 ± 7.1 (P = .012). The intervention group also had higher scores on the open-ended medical knowledge test (27.83 ± 3.07 vs 22.25 ± 4.67; P = .002), but self-confidence scores were not different between groups (P = .64). CONCLUSIONS: CEVL neuraxial is a novel prerotation teaching tool that may enhance the traditional initial teaching of combined spinal-epidural procedures in obstetric anesthesiology. Future research should examine whether the use of web-based learning tools impacts long-term provider performance or patient outcomes.


Asunto(s)
Anestesia Epidural/métodos , Anestesia Obstétrica/normas , Anestesia Raquidea/métodos , Anestesiología/educación , Lista de Verificación , Competencia Clínica , Internado y Residencia , Anestesia Epidural/instrumentación , Anestesia Obstétrica/métodos , Anestesia Raquidea/instrumentación , Anestesiología/métodos , Anestesiología/normas , Cateterismo , Catéteres , Instrucción por Computador/métodos , Femenino , Humanos , Internet , Trabajo de Parto , Masculino , Obstetricia , Embarazo , Autoimagen , Programas Informáticos , Resultado del Tratamiento
6.
Anaesthesia ; 74(5): 619-629, 2019 May.
Artículo en Inglés | MEDLINE | ID: mdl-30793289

RESUMEN

To avoid potentially fatal wrong-route neuraxial drug errors, international standard ISO 80369-6 specifying a non-Luer neuraxial connector design was published in 2016. We describe usability studies used in development of the design. Thirty-eight doctors and 17 nurses performed simulated procedures on manikins, using devices fitted with Luer connectors or draft ISO 80369-6 'non-Luer' connectors. The procedures included spinal anaesthesia; intrathecal chemotherapy; lumbar puncture, cerebrospinal fluid collection and pressure measurement; epidural catheter placement with bolus injection and critical care use. Participants attempted cross connection between neuraxial connectors and a range of other medical device connectors, including those from the ISO 80369 small-bore connector series. Video recording analysis was used for all assessments. Participants subjectively assessed performance of the draft non-Luer connector, including suitability for routine clinical use. Participants performed 198 procedures. The connector achieved easy, leak-free connections. The willingness of participants to use the non-Luer connectors were: spinal anaesthesia 100%; intrathecal chemotherapy 88%; lumbar puncture, cerebrospinal fluid collection and pressure measurement 93%; epidural catheter placement with bolus injection 78%; critical care use 100%. Concerns raised were generally device related, rather than connector related. Most cross-connection attempts failed, even using above clinical forces and, when successful, were judged of low clinical risk potential; the exception was a malaligned connection between the non-Luer slip and female Luer connectors. This led to revision of the dimensional tolerances of the non-Luer connector to reduce this risk, before publication of the final specification in 2016. We conclude that the ISO 80369-6 neuraxial non-Luer connector is suitable for clinical use.


Asunto(s)
Anestesia Raquidea/instrumentación , Errores de Medicación/prevención & control , Antineoplásicos/administración & dosificación , Competencia Clínica , Diseño de Equipo , Seguridad de Equipos , Humanos , Inyecciones Epidurales/instrumentación , Inyecciones Espinales/instrumentación , Maniquíes , Seguridad del Paciente , Punción Espinal/instrumentación
7.
Curr Opin Anaesthesiol ; 32(3): 315-324, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30789839

RESUMEN

PURPOSE OF REVIEW: Central neuraxial blockade is increasingly the anaesthetic management of choice for parturients, including in higher risk pregnancies. Although they are usually effective and safe, there are potentially devastating neurological complications that may present either overtly or insidiously. A thorough understanding of the variety of potential neurological complications is essential to adequately consent patients in addition to diagnosing and managing complications following neuraxial anaesthesia. This review aims to describe a number of potential neurological injuries that may occur and suggested management based on available evidence. RECENT FINDINGS: Current evidence supports neuraxial anaesthesia as a safe management strategy in low and many higher risk pregnancies, with a low overall incidence of neurological complications. Neuraxial blockade is safe in patients with platelet counts greater than 70 000/µl and the risk of infective complications secondary to epidural catheterization remains low until day five post procedure. There is also some early evidence supporting the use of transnasal local anaesthetic as a strategy for managing postdural puncture headache. SUMMARY: Difficulty remains in establishing absolute risk of complications and optimal management strategies given the low overall number of patients affected and heterogeneity of therapy. There may be a role for centralized registration of postneuraxial complications in obstetric patients to further develop our collective understanding of these conditions.


Asunto(s)
Anestesia Epidural/efectos adversos , Anestesia Obstétrica/efectos adversos , Anestesia Raquidea/efectos adversos , Infecciones Relacionadas con Catéteres/epidemiología , Enfermedades del Sistema Nervioso/epidemiología , Administración Intranasal , Anestesia Epidural/instrumentación , Anestesia Epidural/métodos , Anestesia Obstétrica/instrumentación , Anestesia Obstétrica/métodos , Anestesia Raquidea/instrumentación , Anestesia Raquidea/métodos , Anestésicos Locales/administración & dosificación , Antibacterianos/uso terapéutico , Infecciones Relacionadas con Catéteres/etiología , Infecciones Relacionadas con Catéteres/terapia , Cateterismo , Catéteres/efectos adversos , Femenino , Humanos , Incidencia , Enfermedades del Sistema Nervioso/etiología , Enfermedades del Sistema Nervioso/terapia , Embarazo , Embarazo de Alto Riesgo
8.
Anesth Analg ; 126(4): 1349-1352, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-28991119

RESUMEN

The aim of this study was to find the optimal table height to facilitate insertion of the spinal needle at a 90° angle and to reduce the anesthesiologist's discomfort. Sixty patients were randomly allocated according to landmarks on the anesthesiologist's body: umbilicus (group U), lowest rib margin (R), xiphoid process (X), and nipple (N). The coronal insertion angle between the patient's skin and the spinal needle was obtuse in groups U and R, and 90° in group X. We demonstrated that high operating tables at the xiphoid and nipple level facilitate more optimal needle entry angles while reducing the discomfort and joint flexion of anesthesiologists during spinal anesthesia.


Asunto(s)
Anestesia Raquidea/métodos , Anestesiólogos , Salud Laboral , Mesas de Operaciones , Postura , Adolescente , Adulto , Anciano , Anestesia Raquidea/instrumentación , Diseño de Equipo , Ergonomía , Femenino , Humanos , Inyecciones Espinales , Masculino , Persona de Mediana Edad , Agujas , Posicionamiento del Paciente , Estudios Prospectivos , República de Corea , Método Simple Ciego , Adulto Joven
9.
Anaesthesia ; 72(6): 749-754, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28251614

RESUMEN

We investigated the flow rates of 25-G and 27-G spinal needles, of 90-mm and 120-mm lengths, from Vygon, BD, B. Braun and Pajunk; the needles had either a Luer connector, or a Surety® or UniVia® non-Luer connector. We used a bench-top model of entering the spinal space, pressurised to 35 cmH2 O to simulate cerebrospinal fluid pressure in the sitting position. We examined the time to first appearance of simulated cerebrospinal fluid in the needle hub, as well as the amount of fluid collected over 120 s after the needle was introduced. The mean (SD) times to first appearance of fluid in the needle hub of Luer spinal needles varied from 0.36 (0.22) s for the 25-G 90-mm BD to 3.14 (0.72) s for the 27-G 120-mm B. Braun, and in the non-Luer spinal needles from 0.22 (0.17) s for the 25-G 90-mm B. Braun to 2.99 (0.71) s for the 27-G 120-mm Pajunk. There was a significant difference in the time to first appearance of fluid in the needle hub between Luer and non-Luer needles of the same type for seven of 14 comparisons made, of which four showed slower appearance of fluid in the non-Luer version. In some of these cases, the time to appearance of fluid was nearly twice as long with the non-Luer counterpart. The mean (SD) weight of fluid collected in 120 s using the Luer spinal needles varied from 0.21 (0.05) g for the 27-G 120-mm Pajunk to 1.21 (0.18) g for the 25-G 90-mm Vygon, and using the non-Luer spinal needles from 0.25 (0.05) g for the 27-G 120-mm Pajunk to 1.55 (0.05) g for the 25-G 90-mm B. Braun. All of the needle types showed a greater weight of fluid collected using the non-Luer compared with the Luer version, with six of the 14 needle types showing a significant difference. Significant variations in flow were also seen between the same needle type from different manufacturers. We conclude that changing from Luer to non-Luer versions of spinal needles does not merely change the hub design and connection, but may introduce important differences in function.


Asunto(s)
Anestesia Raquidea/instrumentación , Agujas , Líquido Cefalorraquídeo/química , Diseño de Equipo , Humanos
10.
Anaesthesia ; 72(9): 1125-1133, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28696015

RESUMEN

We investigated the strength of commonly used spinal needles in relation to the amount of deformation, and registered forces during standardised testing. We investigated differences between manufacturers for the same length and gauge of Luer and non-Luer needles, and examined the effect of the internal stylet in terms of needle strength. A specialised rig was designed to perform the testing in both the horizontal and axial plane, reflecting common industrial tests and clinical use. Needles from four commonly used manufacturers were used (Vygon, Becton Dickinson, B Braun, and Pajunk). Needles of 25 G and 27 G were tested in 90-mm and 120-mm lengths. We found significant differences in terms of the size of final deformation and 'toughness'/resistance to deformation between needles of different brands. There were also significant differences between horizontal tests conducted as an industry standard and our own axial test. This may have bearing on clinical use in terms of the incidence of bending and breakage. The presence of the internal stylet resulted in significantly greater toughness in many needles, but had little effect on the degree of deformation. Comparison of Luer and non-Luer needles of the same brand and size showed few significant differences in strength. This result is reassuring, given the imminent change from Luer to non-Luer needles that is to occur in the UK.


Asunto(s)
Anestesia Raquidea/instrumentación , Agujas , Diseño de Equipo , Sector de Atención de Salud , Humanos , Inyecciones Espinales , Fenómenos Mecánicos , Agujas/normas , Reino Unido
11.
J Obstet Gynaecol ; 37(6): 719-722, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28375713

RESUMEN

Spinal needles with different diameters can be used to prevent side effects in patients undergoing spinal anaesthesia. However, the velocity of local anaesthetic changes through the spinal needle depending on the diameter of it. Local anaesthetic injection velocity has been reported to be associated with the spinal block level. We aimed to compare spinal needles of different diameters with the same local anaesthetic volumetric flow rate in terms of spinal blockade and hemodynamics in obstetric patients. Eighty-four patients received spinal anaesthesia by either a 25G needle or 29G with the same volumetric flow rate. Block levels, adverse effects, ephedrine given and a success rate of spinal anaesthesia were significantly higher in 25G than in 29G (p < .05). Athough the use of 29G was associated with a low level of block, a sufficient block level was generated for caesarean section. Furthermore, in spite of the technical difficulty, use of 29G was accompanied by a decreased incidence of maternal hypotension, bradycardia and a lowered ephedrine administration. Impact statement Local spinal anaesthetic injections at faster flows cause turbulent flow leading to lower anaesthesia concentrations. The control of spinal anaesthesia levels has some difficulties due to anatomical repositioning, especially in pregnant patients. Also, it can cause frequent hemodynamic complications including hypotension and bradycardia, complications that may also have inadvertent effects on foetus. In this study, we showed that smaller diameter spinal needles provided safer spinal anaesthesia levels and a lower incidence of hemodynamic complications.


Asunto(s)
Anestesia Raquidea/instrumentación , Cesárea , Adulto , Anestesia Raquidea/efectos adversos , Femenino , Hemodinámica , Humanos , Embarazo , Estudios Prospectivos , Adulto Joven
12.
Anaesthesist ; 66(2): 115-121, 2017 Feb.
Artículo en Alemán | MEDLINE | ID: mdl-28120016

RESUMEN

We report the rare case of an in situ fracture of a spinal needle within the setting of repeated caesarean delivery in a 28-year-old pregnant woman and discuss the responsible underlying factors. In particular, a wrong technique, limited experience, difficulties to identify the anatomical landmarks, as well as the use of spinal needles smaller than 25 G might promote such a complication. In order to ensure the stability of the spinal needle and to avoid an in situ fracture, the spinal needle should be never moved without the stylet. In case of repeated bone contact, a well-experienced anaesthetist should be consulted, the spinal needle should be replaced and the use of ultrasound is recommended. Next, the use of an atraumatic spinal needle greater than 27 G should be considered to facilitate intrathecal puncture and to avoid the in situ fracture of a spinal needle. Within this context, the risk of post-spinal puncture headache should be balanced. If an in situ fracture of a spinal needle happens, its subsequent removal should be planned without delay by an interdisciplinary team and the anaesthetic method should be chosen with consideration of patient-specific risk factors.


Asunto(s)
Anestesia Obstétrica/instrumentación , Anestesia Raquidea/instrumentación , Cesárea/métodos , Agujas , Adulto , Puntos Anatómicos de Referencia , Remoción de Dispositivos/métodos , Falla de Equipo , Femenino , Humanos , Errores Médicos , Embarazo , Ultrasonografía Intervencional
13.
Niger J Clin Pract ; 20(8): 992-997, 2017 08.
Artículo en Inglés | MEDLINE | ID: mdl-28891544

RESUMEN

BACKGROUND: Identifying the epidural space is essential during epidural anesthesia (EA). Pressure of the epidural space in pregnancy is higher than that in nonpregnant woman. Loss of resistance (LOR) method is the most commonly preferred method for identifying the epidural space. Epidrum and Epi-Jet are recently innovated supporting devices that facilitate identifying process for epidural space. In this study we aimed to compare Epidrum, Epi-Jet, and LOR methods in identifying the epidural space, feasibility of technique. METHODS: Two hundred and forty pregnant women who were scheduled for caesarian section surgery under lumbar EA or combined spinal epidural anesthesia (CSEA) were randomized into three groups (Group I Epidrum, n = 80), Group II (Epi-Jet, n = 80), and Group III (LOR, n = 80). We recorded the time required to identify the epidural space and deflation of Epidrum balloon and Epi-Jet syringe, number of attempts, additional methods used to identify epidural space, usefulness of methods, accuracy of identification of epidural space, and outcomes of epidural catheterization. RESULTS: There were no significant differences between the groups with respect to demographic data, duration of deflation of Epidrum balloon and Epi-Jet syringe and distance between skin and epidural space. The mean time required to enter epidural space in Group I was shorter than that in Group II (P = 0.031). Feasibility of Epi-Jet was easier than that of Epidrum (P = 0.015). Number of uncertainties of epidural space identification was higher in Group I than that in Group II (P = 0.009). Also, the requirement for LOR to confirm epidural space and failure rates was higher in Group I than Group II (P < 0.001). CONCLUSION: We suggest that Epi-Jet is superior to Epidrum in pregnant patients in terms of clarity of epidural space identification, usefulness, and success rates of EA or CSEA.


Asunto(s)
Anestesia Epidural/métodos , Anestesia Obstétrica/métodos , Anestesia Raquidea/métodos , Cesárea , Adulto , Anestesia Epidural/instrumentación , Anestesia Obstétrica/instrumentación , Anestesia Raquidea/instrumentación , Espacio Epidural , Femenino , Humanos , Embarazo , Jeringas , Factores de Tiempo
14.
Anesthesiology ; 125(3): 516-24, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27380107

RESUMEN

BACKGROUND: It is unclear whether recognition of epidural catheter failures is delayed with combined spinal epidural technique (CSE) compared to traditional epidural technique (EPID) when used for labor analgesia. The authors hypothesized that recognition of failed catheters is not delayed by CSE. METHODS: Anesthetic, obstetric, and quality assurance records from 2,395 labor neuraxial procedures (1,440 CSE and 955 EPID) performed at Forsyth Medical Center (Winston-Salem, North Carolina) between June 30 and December 31, 2012, were retrospectively analyzed. The primary outcome was catheter survival (failure-free) time during labor analgesia. A proportional hazards model with the counting method was used to assess relationships between the techniques and survival (failure-free) time of catheters, while controlling for subjects' body mass index and providers' level of training in the final best-fit multivariable regression model. RESULTS: Cumulative incidence of epidural catheter failures was 6.6% for CSE and 11.6% for EPID (P = 0.001). In the multivariable regression model, catheters placed with CSE versus epidural were less likely to fail (hazard ratio, 0.58; 95% CI, 0.43 to 0.79; P = 0.0002) for labor analgesia. Among the catheters that failed, there was no overall difference in failure time course between the techniques (hazard ratio, 1.17; 95% CI, 0.89 to 1.54; P = 0.26) even though more failed catheters with CSE (48.4%) than with EPID (30.6%) were recognized within the first 30 min of placement (P = 0.009). CONCLUSIONS: In this cohort, CSE has a significantly lower risk of overall epidural catheter failures than EPID and does not delay recognition of epidural catheter failures. Choice of CSE versus EPID should be based on overall risk of failure, efficacy, and side effects.


Asunto(s)
Analgesia Epidural/instrumentación , Analgesia Obstétrica/instrumentación , Anestesia Raquidea/instrumentación , Falla de Equipo/estadística & datos numéricos , Adulto , Analgesia Epidural/métodos , Analgesia Obstétrica/métodos , Anestesia Raquidea/métodos , Catéteres , Estudios de Cohortes , Quimioterapia Combinada , Femenino , Humanos , North Carolina , Embarazo , Estudios Retrospectivos , Análisis de Supervivencia , Factores de Tiempo
15.
Headache ; 56(3): 501-10, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26952012

RESUMEN

OBJECTIVE: The aim of this meta-analysis was to evaluate the postdural puncture headache after spinal anesthesia with Whitacre spinal needles compared with Quincke spine needles. METHODS: We searched several databases, including PubMed, Embase, ISI Web of Knowledge, and Cochrane Central Register of Controlled Trials until October 10th, 2014, for randomized controlled trials that compared spinal anesthesia with Whitacre spinal needles or Quincke spine needles for postdural puncture headache. Two reviewers independently screened the literature, assessed the risk for bias and extracted data. We used RevMan 5.3 software to perform the meta-analysis. Studies were included for the main end points if they addressed the following: frequency of postdural puncture headache, severity of postdural puncture headache as assessed by limitation of activities, and frequency of epidural blood patch. RESULTS: Nine randomized controlled trials were included for meta-analysis. The meta-analysis showed that spinal anesthesia with Whitacre spinal needles achieved lower incidence of postdural puncture headache(RR 0.34; 95% CI [0.22, 0.52]; P < .00001); in addition, the severity of postdural puncture headache was lower in the Whitacre spinal needle group (RR 0.32; 95% CI [0.16, 0.66]; P = .002). Furthermore, the frequency of an epidural blood patch in the Whitacre spinal needle group was lower compared with that in the Quincke spine needle group (RR 0.15; 95% CI [0.04, 0.51]; P = .002). CONCLUSION: We suggest the Whitacre spinal needles as a superior choice for spinal anesthesia compared with Quincke spine needles.


Asunto(s)
Anestesia Raquidea/efectos adversos , Anestesia Raquidea/instrumentación , Cefalea Pospunción de la Duramadre/epidemiología , Humanos , Incidencia , Agujas , Cefalea Pospunción de la Duramadre/etiología , Ensayos Clínicos Controlados Aleatorios como Asunto , Punción Espinal/efectos adversos , Punción Espinal/instrumentación
16.
J Anesth ; 30(5): 855-63, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-27468735

RESUMEN

PURPOSE: Post-dural puncture headache (PDPH) is a well-known neurological outcome caused by leakage of cerebrospinal fluid during neuraxial anesthesia. Studies aimed at assessing the efficacy of finer gauged spinal needles to reduce the incidence of PDPH have produced conflicting results. We have therefore examined the effect of the gauge of cutting needles and pencil-point needles, separately, on the incidence of PDPH. METHODS: The PubMed, EMBASE and Google Scholar databases were searched for randomized studies which compared PDPH incidence in a head-to-head analysis of individual needle gauges of similar needle designs (cutting and pencil-point). A meta-regression analysis was performed taking into account various covariates, such as needle gauge and design, mean age of patient population, surgery type, percentage of males and females in study population and year of publication. RESULTS: Of the 22 studies (n = 5631) included in the analysis, 12 (n = 3148) and ten (n = 2483) compared different gauges of cutting needles and pencil-point needles, respectively. After adjusting for covariates, meta-regression analysis was performed for all studies that randomly compared individual needle gauges of similar needle design. Whereas the incidence of PDPH inversely correlated with gauge in cutting needles (ß = -1.36 % per gauge, P = 0.037), no relationship was noted in pencil-point needles (ß = -0.32 % per gauge, P = 0.114). Female gender was the only covariate that reached a statistically significant correlation with the incidence of PDPH in both models. CONCLUSIONS: A significant relationship between needle gauge and subsequent rate of PDPH was noted in cutting needles, but not pencil-point needles.


Asunto(s)
Anestesia Raquidea/efectos adversos , Anestesia Raquidea/instrumentación , Agujas , Cefalea Pospunción de la Duramadre/epidemiología , Anestesia Raquidea/métodos , Humanos , Incidencia , Cefalea Pospunción de la Duramadre/etiología , Punción Espinal/efectos adversos
17.
Anaesthesia ; 70(6): 691-8, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25627651

RESUMEN

Hypotension occurs commonly during spinal anaesthesia for caesarean section, associated with maternal and fetal adverse effects. We developed a double-vasopressor automated system with a two-step algorithm and continuous non-invasive haemodynamic monitoring using the Nexfin device. The system delivered 25 µg phenylephrine every 30 s when systolic blood pressure was between 90% and 100% of baseline, or 2 mg ephedrine at this blood pressure range and heart rate < 60 beats.min(-1) ; and 50 µg phenylephrine or 4 mg ephedrine when systolic blood pressure was < 90% of baseline with the same heart rate criterion. Fifty-seven women received standardised spinal anaesthesia. Twenty-seven (47.4%) had at least one reading of hypotension defined as systolic blood pressure < 80% baseline. Systolic blood pressure was within 20% of the baseline in a mean (SD) of 79.8 (20.9)% of measurements. Fifty-three (93.0%) women required phenylephrine before delivery while 10 (17.5%) required ephedrine. Six women (10.5%) experienced nausea and three (5.3%) vomited. The system was able to achieve a low incidence of maternal hypotension with good maternal and fetal outcomes.


Asunto(s)
Anestesia Raquidea/instrumentación , Cesárea/instrumentación , Hemodinámica/efectos de los fármacos , Monitoreo Intraoperatorio/instrumentación , Atención Perioperativa/instrumentación , Vasoconstrictores/administración & dosificación , Vasoconstrictores/uso terapéutico , Adulto , Anestesia Obstétrica , Anestesia Raquidea/métodos , Automatización , Presión Sanguínea/efectos de los fármacos , Cesárea/métodos , Efedrina/administración & dosificación , Efedrina/uso terapéutico , Femenino , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Hipotensión/tratamiento farmacológico , Recién Nacido , Monitoreo Intraoperatorio/métodos , Atención Perioperativa/métodos , Fenilefrina/administración & dosificación , Fenilefrina/uso terapéutico , Náusea y Vómito Posoperatorios/epidemiología , Embarazo , Complicaciones Cardiovasculares del Embarazo/tratamiento farmacológico , Resultado del Embarazo , Resultado del Tratamiento
19.
Anaesthesia ; 68(6): 562-70, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23627527

RESUMEN

We evaluated seven non-Luer spinal needles in a two-part study. In part 1, we measured the time to see and collect simulated cerebrospinal fluid. In part 2, clinicians scored needle quality using a standardised questionnaire. The mean (SD) times to see cerebrospinal fluid varied in the lateral position from 4.2 (0.3) s (Vygon) to 25.2 (1.5) s (Sarstedt), and in the sitting position from 1.7 (0.2) s (BBraun) to 6.6 (0.3) s (Sarstedt). The time to collect cerebrospinal fluid varied from 43 (2.5) s (Vygon) to 139 (9.6) s (Pajunk) and from 19 (0.4) s (BBraun) to 34 (1.7) s (Pajunk), for the lateral and sitting positions, respectively. Median (IQR [range]) satisfaction scores in 205 needle function assessments were as follows: Sarstedt 9.0 (8.0-9.3 [5.0-10.0]); BD 8.0 (7.0-9.5 [3.0-10.0]); Pajunk 9.0 (8.0-9.8 [5.0-10.0]); Neurax 8.0 (7.0-9.0 [2.0-9.0]); Smiths 8.0 (7.0-9.0 [4.0-10.0]); Vygon 8.0 (7.5-9.0 [5.0-10.0]); and BBraun 9.0 (9.0-10.0 [7.0-10.0]). The difference in satisfaction scores between the BBraun and Neurax was significant (p < 0.01). A number of recurrent problems were found during the evaluation. The variation in time to collect cerebrospinal fluid samples may have implications for non-anaesthetic practice. This evaluation provides a baseline to assist others in commencing their procurement process.


Asunto(s)
Anestesia Raquidea/instrumentación , Seguridad de Equipos/instrumentación , Inyecciones Espinales/instrumentación , Diseño de Equipo , Humanos , Agujas , Postura
20.
J Anesth ; 27(2): 224-30, 2013 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-23065050

RESUMEN

PURPOSE: Unilateral spinal anesthesia is beneficial in patients undergoing unilateral leg surgery. The direction and the shape of the spinal needle are thought to influence the unilateral distribution of the local anesthetic in the intrathecal space. Therefore, to study the effects of different spinal needles we compared the effects of the Whitacre and Quincke spinal needles. METHODS: This was a prospective, randomized, double-blind study of 60 consecutive outpatients scheduled for unilateral lower-limb surgery. The patients were randomized to receive spinal anesthesia with 1.2 ml of 0.5 % plain bupivacaine using either a 27-G Whitacre or a Quincke needle. One half of the local anesthetic was injected towards the nondependent side and the other half was directed cranially. The spread of spinal anesthesia, both sensory and motor blocks, was defined as the primary endpoint and was recorded at 10, 20, and 30 min after the spinal injection, at the end of the operation, 2 h after the spinal injection, and every 30 min thereafter until there was no motor block. Secondary endpoints included patient satisfaction and adverse effects. RESULTS: There was no difference in the spread of sensory or motor blocks between the Whitacre and the Quincke groups. However, the sensory and motor blocks on the operated and the nonoperated sides were significantly different at all testing times, as expected. There was no difference in the incidence of adverse effects or patient satisfaction scores between the Whitacre and the Quincke groups. CONCLUSION: Unilateral spinal block for outpatient surgery can be achieved with both pencil-point (Whitacre) and Quincke needles using 6.0 mg of plain bupivacaine. Neither the spread of sensory and motor blocks nor the corresponding recovery times appeared to be different between the groups. Nor was there any difference in patient satisfaction.


Asunto(s)
Anestesia Raquidea/instrumentación , Agujas , Adolescente , Adulto , Anestesia Raquidea/efectos adversos , Anestesia Raquidea/métodos , Anestésicos Locales/administración & dosificación , Bupivacaína/administración & dosificación , Método Doble Ciego , Determinación de Punto Final , Femenino , Humanos , Complicaciones Intraoperatorias/epidemiología , Extremidad Inferior/cirugía , Masculino , Persona de Mediana Edad , Agujas/efectos adversos , Bloqueo Nervioso/instrumentación , Bloqueo Nervioso/métodos , Dolor/epidemiología , Dolor/etiología , Dolor Postoperatorio/epidemiología , Posicionamiento del Paciente , Satisfacción del Paciente , Complicaciones Posoperatorias/epidemiología , Estudios Prospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA