Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 612
Filtrar
Más filtros

Intervalo de año de publicación
1.
J Proteome Res ; 23(5): 1779-1787, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38655860

RESUMEN

To prevent doping practices in sports, the World Anti-Doping Agency implemented the Athlete Biological Passport (ABP) program, monitoring biological variables over time to indirectly reveal the effects of doping rather than detect the doping substance or the method itself. In the context of this program, a highly multiplexed mass spectrometry-based proteomics assay for 319 peptides corresponding to 250 proteins was developed, including proteins associated with blood-doping practices. "Baseline" expression profiles of these potential biomarkers in capillary blood (dried blood spots (DBS)) were established using multiple reaction monitoring (MRM). Combining DBS microsampling with highly multiplexed MRM assays is the best-suited technology to enhance the effectiveness of the ABP program, as it represents a cost-effective and robust alternative analytical method with high specificity and selectivity of targets in the attomole range. DBS data were collected from 10 healthy athlete volunteers over a period of 140 days (28 time points per participant). These comprehensive findings provide a personalized targeted blood proteome "fingerprint" showcasing that the targeted proteome is unique to an individual and likely comparable to a DNA fingerprint. The results can serve as a baseline for future studies investigating doping-related perturbations.


Asunto(s)
Proteínas Sanguíneas , Doping en los Deportes , Pruebas con Sangre Seca , Proteómica , Humanos , Doping en los Deportes/prevención & control , Proteómica/métodos , Proteínas Sanguíneas/análisis , Pruebas con Sangre Seca/métodos , Pruebas con Sangre Seca/normas , Masculino , Valores de Referencia , Adulto , Biomarcadores/sangre , Espectrometría de Masas/métodos , Detección de Abuso de Sustancias/métodos , Proteoma/análisis , Atletas , Femenino
2.
Anal Chem ; 96(1): 238-247, 2024 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-38117670

RESUMEN

Hypoxia-inducible factor (HIF) stabilizers are listed in the World Anti-Doping Agency's prohibited list as they can increase aerobic exercise capacity. The rapid pace of emergence of highly structurally diverse HIF stabilizers could pose a risk to conventional structure-based methods in doping control to detect new investigational drugs. Therefore, we developed a strategy that is capable of detecting the presence of any HIF stabilizer, irrespective of its structure, by detecting biological activity. Previously developed cell-based HIF1/2 assays were optimized to a stable format and evaluated for their screening potential toward HIF stabilizers. Improved pharmacological characterization was established by the stable cell-based formats, and broad specificity was demonstrated by pharmacologically characterizing a diverse set of HIF stabilizers (including enarodustat, IOX2, IOX4, MK-8617, JNJ-42041935). The methodological (in solvent) limit of detection of the optimal HIF1 stable bioassay toward detecting the reference compound roxadustat was 100 nM, increasing to 50-100 ng/mL (corresponding to 617-1233 nM in-well) in matching urine samples, owing to strong matrix effects. In a practical context, a urinary limit of detection of 1.15 µg/mL (95% detection rate) was determined, confirming the matrix-dependent detectability of roxadustat in urine. Pending optimization of a universal sample preparation strategy and/or a methodology to correct for the matrix effects, this untargeted approach may serve as a complementing method in antidoping control, as theoretically, it would be capable of detecting any unknown substance with HIF stabilizing activity.


Asunto(s)
Doping en los Deportes , Detección de Abuso de Sustancias/métodos , Glicina/química , Pirazoles , Triazoles
3.
Anal Chem ; 96(12): 4835-4844, 2024 03 26.
Artículo en Inglés | MEDLINE | ID: mdl-38488022

RESUMEN

The rapid proliferation of new psychoactive substances (NPS) poses significant challenges to conventional mass-spectrometry-based identification methods due to the absence of reference spectra for these emerging substances. This paper introduces PS2MS, an AI-powered predictive system designed specifically to address the limitations of identifying the emergence of unidentified novel illicit drugs. PS2MS builds a synthetic NPS database by enumerating feasible derivatives of known substances and uses deep learning to generate mass spectra and chemical fingerprints. When the mass spectrum of an analyte does not match any known reference, PS2MS simultaneously examines the chemical fingerprint and mass spectrum against the putative NPS database using integrated metrics to deduce possible identities. Experimental results affirm the effectiveness of PS2MS in identifying cathinone derivatives within real evidence specimens, signifying its potential for practical use in identifying emerging drugs of abuse for researchers and forensic experts.


Asunto(s)
Aprendizaje Profundo , Drogas Ilícitas , Cromatografía Liquida/métodos , Psicotrópicos/análisis , Espectrometría de Masas/métodos , Drogas Ilícitas/análisis , Detección de Abuso de Sustancias/métodos
4.
Expert Rev Proteomics ; 21(1-3): 27-39, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38214680

RESUMEN

INTRODUCTION: The analysis of doping control samples is preferably performed by mass spectrometry, because obtained results meet the highest analytical standards and ensure an impressive degree of reliability. The advancement in mass spectrometry and all its associated technologies thus allow for continuous improvements in doping control analysis. AREAS COVERED: Modern mass spectrometric systems have reached a status of increased sensitivity, robustness, and specificity within the last decade. The improved sensitivity in particular has, on the other hand, also led to the detection of drug residues that were attributable to scenarios where the prohibited substances were not administered consciously but rather by the unconscious ingestion of or exposure to contaminated products. These scenarios and their doubtless clarification represent a great challenge. Here, too, modern MS systems and their applications can provide good insights in the interpretation of dose-related metabolism of prohibited substances. In addition to the development of new instruments itself, software-assisted analysis of the sometimes highly complex data is playing an increasingly important role and facilitating the work of doping control laboratories. EXPERT OPINION: The sensitive analysis and evaluation of a higher number of samples in a shorter time is made possible by the ongoing developments in mass spectrometry.


Asunto(s)
Doping en los Deportes , Espectrometría de Masas en Tándem , Humanos , Espectrometría de Masas en Tándem/métodos , Detección de Abuso de Sustancias/métodos , Reproducibilidad de los Resultados , Estándares de Referencia
5.
Clin Chem ; 70(7): 934-947, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38549034

RESUMEN

BACKGROUND: Substance use during pregnancy is common, as is biological testing that is intended to help identify prenatal exposures. However, there is no standardized requirement for biological testing with either maternal or newborn specimens, nor is there standardization related to when testing occurs, how frequently testing occurs, what specimen(s) to test, what substances to test for, or how to perform testing. CONTENT: We review common specimen types tested to detect maternal and newborn substance exposure with a focus on urine, meconium, and umbilical cord tissue. We also review common analytical methods used to perform testing, including immunoassay, and mass spectrometry platforms. Considerations regarding the utilization of testing relative to the purpose of testing, the drug analyte(s) of interest, the specific testing employed, and the interpretation of results are emphasized to help guide decisions about clinical utilization of testing. We also highlight specific examples of unexpected results that can be used to guide interpretation and appropriate next steps. SUMMARY: There are strengths and limitations associated with all approaches to detecting substance exposure in pregnant persons as well as biological testing to evaluate a newborn with possible substance exposure. Standardization is needed to better inform decisions surrounding evaluation of substance exposures in pregnant people and newborns. If biological sampling is pursued, testing options and results must be reviewed in clinical context, acknowledging that false-positive and -negative results can and do occur.


Asunto(s)
Meconio , Detección de Abuso de Sustancias , Humanos , Recién Nacido , Embarazo , Femenino , Detección de Abuso de Sustancias/métodos , Meconio/química , Trastornos Relacionados con Sustancias/diagnóstico , Trastornos Relacionados con Sustancias/orina , Inmunoensayo/métodos , Cordón Umbilical , Exposición Materna/efectos adversos
6.
Clin Chem ; 70(7): 978-986, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38757262

RESUMEN

BACKGROUND: Abuse of fentanyl and its analogs is a major contributor to the opioid overdose epidemic in the United States, but detecting and quantifying trace amounts of such drugs remains a challenge without resorting to sophisticated mass spectrometry-based methods. METHODS: A sensitive immunoassay with a sub-picogram limit of detection for fentanyl and a wide range of fentanyl analogs has been developed, using a novel high-affinity antibody fused with NanoLuc, a small-size luciferase that can emit strong and stable luminescence. When used with human urine samples, the assay has a sub-picogram limit of detection for fentanyl, with results fully concordant with LC-MS. RESULTS: When applied to clinical samples, the novel chemiluminescence immunoassay can detect low positive fentanyl missed by routine screening immunoassays, with a limit of detection of 0.8 pg/mL in human urine. When applied to environmental samples, the assay can detect levels as low as 0.25 pg fentanyl per inch2 of environment surface. Assay turnaround time is less than 1 h, with inexpensive equipment and the potential for high-throughput automation or in-field screening. CONCLUSIONS: We have established a novel assay that may have broad applications in clinical, environmental, occupational, and forensic scenarios for detection of trace amounts of fentanyl and its analogs.


Asunto(s)
Fentanilo , Mediciones Luminiscentes , Fentanilo/orina , Fentanilo/análisis , Humanos , Inmunoensayo/métodos , Mediciones Luminiscentes/métodos , Límite de Detección , Detección de Abuso de Sustancias/métodos , Analgésicos Opioides/orina , Analgésicos Opioides/análisis
7.
Anal Biochem ; 691: 115526, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38621604

RESUMEN

The imperative for the point-of-care testing of methamphetamine and cocaine in drug abuse prevention necessitates innovative solutions. To address this need, we have introduced a multi-channel wearable sensor harnessing CRISPR/Cas12a system. A CRISPR/Cas12a based system, integrated with aptamers specific to methamphetamine and cocaine, has been engineered. These aptamers function as signal-mediated intermediaries, converting methamphetamine and cocaine into nucleic acid signals, subsequently generating single-stranded DNA to activate the Cas12 protein. Additionally, we have integrated a microfluidic system and magnetic separation technology into the CRISPR system, enabling rapid and precise detection of cocaine and methamphetamine. The proposed sensing platform demonstrated exceptional sensitivity, achieving a detection limit as low as 0.1 ng/mL. This sensor is expected to be used for on-site drug detection in the future.


Asunto(s)
Cocaína , Metanfetamina , Pruebas en el Punto de Atención , Dispositivos Electrónicos Vestibles , Cocaína/análisis , Metanfetamina/análisis , Humanos , Técnicas Biosensibles/métodos , Aptámeros de Nucleótidos/química , Sistemas CRISPR-Cas , Detección de Abuso de Sustancias/métodos
8.
Rapid Commun Mass Spectrom ; 38(17): e9856, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38945695

RESUMEN

RATIONALE: To uphold the integrity of horseracing and equestrian sports, it is critical for an equine doping control laboratory to develop a comprehensive screening method to cover a wide range of target substances at the required detection levels in equine urine. METHODS: The procedure involved the enzymatic hydrolysis of 3 mL urine samples followed by solid-phase extraction using HF Bond Elut C18 cartridge. The resulting extracts were then separated on a C18 reversed-phase column and analyzed using liquid chromatography/high-resolution mass spectrometry (LC/HRMS) in both electrospray ionization positive and negative modes in two separate injections. The analytical data were obtained in full scan and product ion scan (PIS) modes in an 11 min LC run. RESULTS: The method can detect 1011 compounds (in both positive and negative ion modes). Over 95% of the target compounds have limits of detections (LODs) ≤10 ng/mL, and more than 50% of the LODs are ≤0.5 ng/mL. The lowest LOD can reach down to 0.01 ng/mL. The applicability of the method was demonstrated by the successful detection of prohibited substances in overseas and domestic equine urine samples. CONCLUSIONS: We have successfully developed a regular screening method for equine urine samples that can detect more than 1000 compounds at sub-ppb levels in both positive and negative ion modes with full scan and PIS using LC/HRMS. Furthermore, this method can theoretically be expanded to accommodate an unlimited number of prohibited substances in full-scan mode.


Asunto(s)
Doping en los Deportes , Límite de Detección , Animales , Caballos/orina , Doping en los Deportes/prevención & control , Cromatografía Liquida/métodos , Detección de Abuso de Sustancias/métodos , Detección de Abuso de Sustancias/veterinaria , Espectrometría de Masas/métodos , Extracción en Fase Sólida/métodos , Reproducibilidad de los Resultados
9.
Rapid Commun Mass Spectrom ; 38(17): e9846, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38923663

RESUMEN

RATIONALE: Lomerizine (LMZ) is an antimigraine drug that works as a calcium channel blocker and has selective effects on the central nervous system. It is metabolized into trimetazidine (TMZ), which is a prohibited substance owing to its performance-enhancing effects in both human and animal sports. Effective doping control measures are imperative to distinguish the source of TMZ in samples to ensure integrity and fairness of the sport, therefore a comprehensive analysis of LMZ metabolites is essential to identify potential biomarkers in camel urine for effective doping control. METHODS: Camel urine samples were collected from four healthy animals following a single oral administration of LMZ at a dosage of 1 mg/kg body weight. In vitro studies were conducted using homogenized camel liver samples. Lomerizine and its metabolites were extracted using solid-phase extraction and analyzed with a Thermo Fisher Orbitrap Exploris liquid chromatography mass spectrometry system. The acquired data was processed with the Compound Discoverer software. RESULTS: The study conducted a comprehensive analysis of LMZ metabolites in camels and identified 10 phase I and one phase II metabolites. The primary pathway for the formation of phase I metabolites was de-alkylation, while phase II metabolite was formed through alkylation of the parent drug. The study provided valuable insights into the unique metabolic pathways of LMZ in camels under specific experimental conditions. CONCLUSION: The developed method enables the detection and characterization of LMZ and its metabolites in camels. The identified metabolites has the potential to act as marker metabolites for the distinctive detection of LMZ in camel urine to ensure efficient analytical strategies for routine doping control applications.


Asunto(s)
Camelus , Doping en los Deportes , Animales , Doping en los Deportes/prevención & control , Piperazinas/orina , Piperazinas/metabolismo , Espectrometría de Masas/métodos , Detección de Abuso de Sustancias/métodos , Detección de Abuso de Sustancias/veterinaria , Cromatografía Liquida/métodos , Masculino
10.
Int J Legal Med ; 138(5): 1791-1800, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38589641

RESUMEN

Non-prescription use of anabolic androgenic steroids (AAS) is associated with an increased risk of premature death. However, these substances are seldom screened in connection with forensic cause-of-death investigation, unless the forensic pathologist specifically suspects use, often based on a positive AAS use history. Since AAS use is often concealed from others, this practice may lead to mistargeting of these analyses and significant underestimation of the true number of AAS positive cases undergoing forensic autopsy. Thus, more accurate diagnostic tools are needed to identify these cases. The main objective of this study was to determine, whether a multivariable model could predict AAS urine assay positivity in forensic autopsies. We analyzed retrospectively the autopsy reports of all cases that had been screened for AAS during forensic cause-of-death investigation between 2016-2019 at the Finnish Institute for Health and Welfare forensic units (n = 46). Binary logistic regression with penalized maximum likelihood estimation was used to generate a nine-variable model combining circumferential and macroscopic autopsy-derived variables. The multivariable model predicted AAS assay positivity significantly better than a "conventional" model with anamnestic information about AAS use only (area under the receiver operating characteristic curve [AUC] = 0.968 vs. 0.802, p = 0.005). Temporal validation was conducted in an independent sample of AAS screened cases between 2020-2022 (n = 31), where the superiority of the multivariable model was replicated (AUC = 0.856 vs. 0.644, p = 0.004). Based on the model, a calculator predicting AAS assay positivity is released as a decision-aiding tool for forensic pathologists working in the autopsy room.


Asunto(s)
Anabolizantes , Autopsia , Detección de Abuso de Sustancias , Humanos , Masculino , Estudios Retrospectivos , Adulto , Anabolizantes/análisis , Anabolizantes/orina , Detección de Abuso de Sustancias/métodos , Femenino , Adulto Joven , Modelos Logísticos , Andrógenos/análisis , Persona de Mediana Edad , Finlandia , Curva ROC , Esteroides Anabólicos Androgénicos
11.
Ann Fam Med ; 22(4): 271-278, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39038971

RESUMEN

PURPOSE: Black birthing parents and their newborns disproportionately experience newborn drug testing for prenatal substance exposure by health care professionals (HCPs), which contributes to Child Protective Services (CPS) reporting, family separation, and termination of parental rights. This qualitative study aims to interrogate dominant power structures by exploring knowledge, attitudes, and experiences of HCPs and CPS professionals regarding the influence of structural racism on inequities in newborn drug testing practices. METHODS: We conducted semistructured interviews with 30 physicians, midwives, nurses, social workers, and CPS professionals guided by an explanatory framework, and conducted inductive, reflexive thematic analysis. RESULTS: We identified 3 primary themes: (1) levels of racism beyond the hospital structure contributed to higher rates of drug testing for Black newborns; (2) inconsistent hospital policies led to racialized application of state law and downstream CPS reporting; and (3) health care professionals knowledge of the benefits and disproportionate harms of CPS reporting on Black families influenced their decision making. CONCLUSION: Health care professionals recognized structural racism as a driver of disproportionate newborn drug testing. Lack of knowledge and skill limitations of HCPs were barriers to dismantling power structures, thus impeding systems-level change. Institutional changes should shift focus from biologic testing and reporting to supporting the mutual needs of birthing parent and child through family-centered substance use treatment. State and federal policy changes are needed to ensure health equity for Black families and eliminate reporting to CPS for prenatal substance exposure when no concern for child abuse and neglect exists.


Asunto(s)
Negro o Afroamericano , Servicios de Protección Infantil , Tamizaje Neonatal , Detección de Abuso de Sustancias , Femenino , Humanos , Recién Nacido , Embarazo , Actitud del Personal de Salud , Personal de Salud/psicología , Tamizaje Neonatal/normas , Investigación Cualitativa , Racismo , Detección de Abuso de Sustancias/normas , Racismo Sistemático/prevención & control
12.
Int J Legal Med ; 138(4): 1307-1314, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38400921

RESUMEN

Prenatal and infant exposure to drugs of abuse is an emerging social and public health problem affecting children health and which may relate to child abuse and neglect. Exposure to drugs of abuse may occur through different routes, including intrauterine, breastfeeding, accidental intake, passive inhalation, and intentional administration. Currently, cases of suspected exposure can be investigated by hair toxicological analysis, the interpretation of which is, however, often difficult, leading to consequent difficulties in the management of such cases. In order to provide a contribution in terms of interpretation of the analytical results, this study aimed to search for the possible existence of elements, from a toxicological point of view, indicative towards the route of exposure. A retrospective study was performed on cases of suspected exposure to drugs of abuse in children aged 0-1 year, evaluated at a University Hospital between 2018 and 2022. Data of children hair toxicological analysis were analyzed and then compared with those of their mothers, when available; 41.6% children tested positive for cocaine. The study found a significant correlation between cocaine and benzoylecgonine concentrations, and a benzoylecgonine/cocaine ratio that tends to decrease as the age of children increases. From the comparison with mothers, a child/mother cocaine concentration ratio lower than 1 was found in all cases of hair sampled within the first week of life, and a ratio greater than or equal to 1 in all cases in which the sampling was performed later. These results, if confirmed in a larger cohort, could represent a contribution in the interpretation of cases of infant exposure to drugs of abuse and be integrated in the context of their multidisciplinary evaluation.


Asunto(s)
Cocaína , Cabello , Humanos , Estudios Retrospectivos , Cocaína/análisis , Cocaína/análogos & derivados , Femenino , Lactante , Cabello/química , Recién Nacido , Masculino , Madres , Análisis de Cabello , Adulto , Embarazo , Detección de Abuso de Sustancias/métodos
13.
Int J Legal Med ; 138(5): 1801-1811, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38831139

RESUMEN

Novel synthetic opioids (NSOs) represent an emerging group of novel psychoactive substances, acting as agonists at the opioid receptors. NSOs include fentanyl-related compounds, e.g. methoxyacetylfentanyl (MeACF), and non-fentanyl analogs, e.g. "U compounds" including U-47700. Here we present three cases of death involving MeACF and U-47700, with particular reference to preliminary data on pharmacokinetics and tissue distribution.After a complete post-mortem examination, general unknown screenings and analysis of drugs of abuse were performed on postmortem samples by immunoassays, gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry. To quantify the analytes of interest in post-mortem blood and tissues, the standard addition method was used. A toxicological significance score (TSS), weighing the role of the NSO in each death case, was assigned.Case 1 died at the hospital after consumption of U-47700, methadone (serum levels: 2,600 ng/ml and 37 ng/ml), tilidine and benzodiazepines. In case 2, U-47700 (204 ng/ml) together with methadone (290 ng/ml), flubromazepam (480 ng/ml) and diazepam (300 ng/ml) were detected in peripheral blood. In case 3, methoxyacetylfentanyl (266 ng/ml), furanylfentanyl (4.3 ng/ml) 4-ANPP (15 ng/ml) and alprazolam (69 ng/ml) were quantified in femoral blood. In all cases, the NSO likely contributed to the death (TSS = 3).NSOs appear to be often consumed in the setting of polydrug intoxications, especially in combination with other opioids and benzodiazepines, which often exert synergistic effects. The standard addition method remains the most reliable in post-mortem analysis and toxicological results should always be evaluated together with circumstantial and autopsy data.


Asunto(s)
Fentanilo , Humanos , Fentanilo/análogos & derivados , Fentanilo/envenenamiento , Fentanilo/sangre , Fentanilo/análisis , Masculino , Adulto , Analgésicos Opioides/envenenamiento , Analgésicos Opioides/sangre , Analgésicos Opioides/análisis , Metadona/envenenamiento , Metadona/sangre , Metadona/análisis , Toxicología Forense , Cromatografía Liquida , Benzodiazepinas/sangre , Benzodiazepinas/envenenamiento , Femenino , Persona de Mediana Edad , Cromatografía de Gases y Espectrometría de Masas , Drogas Ilícitas/sangre , Drogas Ilícitas/envenenamiento , Detección de Abuso de Sustancias , Benzamidas
14.
Analyst ; 149(9): 2762-2768, 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38567533

RESUMEN

The abuse of illicit drugs poses serious threats to the physical and mental health of users, as well as to the overall safety and welfare of society. In this work, we present a newly developed technique for drug detection based on mass spectrometry. This technique combines Leidenfrost desorption with low-temperature arc plasma ionization mass spectrometry. This method is applicable for detecting furanyl fentanyl in complex matrices. Key advantages of this technique include minimal sample fragmentation and high sensitivity for detection. The Leidenfrost desorption plays a pivotal role in this methodology, as it spontaneously concentrates analyte molecules during the gradual evaporation of the solvent. Eventually, these concentrated molecules are redistributed at their highest concentrations, resulting in exceptionally high sensitivity. In the course of our investigation, we achieved a remarkable detection limit of 10 pg mL-1 for furanyl fentanyl in pure water. Moreover, the characteristic ion peaks of furanyl fentanyl can be distinctly identified within complex matrices such as wine, beverages, urine, and lake water. This innovative drug detection technology offers several advantages, including a simple setup, cost-effectiveness, rapid detection, high sensitivity, and minimal sample pretreatment.


Asunto(s)
Fentanilo , Fentanilo/análogos & derivados , Furanos , Límite de Detección , Fentanilo/análisis , Fentanilo/orina , Humanos , Espectrometría de Masas/métodos , Drogas Ilícitas/análisis , Detección de Abuso de Sustancias/métodos , Lagos/análisis , Lagos/química
15.
Ther Drug Monit ; 46(4): 522-529, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38498915

RESUMEN

BACKGROUND: Legally prescribed benzodiazepines (BZDs) and designer BZDs are widely misused and must be determined in multiple contexts (eg, overdose, drug-facilitated sexual assaults, or driving under the influence of drugs). This study aimed to develop a method for measuring serum BZD levels using probe electrospray ionization (PESI) mass spectrometry and an isotope dilution approach. METHODS: A tandem mass spectrometer equipped with a probe electrospray ionization source in multiple reaction monitoring mode was used. Isotope dilution was applied for quantification using a deuterated internal standard at a fixed concentration for alprazolam, bromazepam, diazepam, nordiazepam, oxazepam, temazepam, zolpidem, and zopiclone. This method included designer BZDs: clonazolam, deschloroetizolam, diclazepam, etizolam, flualprazolam, flubromazepam, flubromazolam, meclonazepam, nifoxipam, and pyrazolam. Sample preparation was done by mixing 10 µL of serum with 500 µL of an ethanol/ammonium formate 0.01 mol/L buffer. Complete validation was performed, and the method was compared with liquid chromatography coupled with mass spectrometry (LC-MS/MS) and immunoassays (IC) by analyzing 40 real samples. RESULTS: The analysis time for identification and quantification of the 18 molecules was 2.5 minutes. This method was fully validated, and the limits of quantification varied from 5 to 50 mcg/L depending on the molecule. In the 40 real samples, 100% of molecules (n = 89) were detected by both LC-MS/MS and PESI-MS/MS, and regression analysis showed excellent agreement between the 2 methods (r 2 = 0.98). On IC, bromazepam and zolpidem were not detected in 2 and 1 cases, respectively. CONCLUSIONS: PESI-MS/MS allows serum BZD detection and measurement. Given the isotope dilution approach, a calibration curve was not required, and its performance was similar to that of LC-MS/MS, and its specificity was higher than that of IC.


Asunto(s)
Benzodiazepinas , Espectrometría de Masa por Ionización de Electrospray , Espectrometría de Masas en Tándem , Humanos , Espectrometría de Masa por Ionización de Electrospray/métodos , Benzodiazepinas/sangre , Benzodiazepinas/análisis , Espectrometría de Masas en Tándem/métodos , Cromatografía Liquida/métodos , Detección de Abuso de Sustancias/métodos , Reproducibilidad de los Resultados , Límite de Detección
16.
Ther Drug Monit ; 46(4): 530-536, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38723151

RESUMEN

BACKGROUND: The use of psychoactive substances (PSs) during pregnancy is a major public health concern because of their increasing prevalence worldwide. This study examined the understudied issue of gestational PS consumption in a cohort of Argentine delivering mothers. METHODS: A cross-sectional pilot study involving 51 women receiving delivery care was conducted at the Santa Rosa Hospital in La Pampa, Argentina. Information on maternal sociodemographic characteristics, pregnancy history, and drug use was obtained through standardized interviews. Maternal hair samples were analyzed for alcohol, tobacco, licit, illicit, and prescription substance biomarkers using ultra-high-performance liquid chromatography high-resolution mass spectrometry and gas chromatography mass spectrometry. RESULTS: During pregnancy, 49.0% of participants reported alcohol consumption, 25.5% reported tobacco use, and 23.5% reported cannabis use. Hair samples from 56.9% of the women were positive for illicit PSs, with the most frequent being cocaine (41.2%) and cannabis (15.7%). Among the women, 47.1% consumed alcohol during pregnancy. Of the 24 women with hair ethyl glucuronide ≥5 pg/mg, 33.3% drank until the end of gestation and 58.3% started a social drinking habit in the second half. The analysis also detected prescription substances (anticonvulsants, antidepressants, methadone, opioids, antihistamines, antiemetics, and analgesics), caffeine (70.6%), lidocaine, and levamisole, some of which were cocaine or opioid adulterants. CONCLUSIONS: This is the first study to objectively assess the consumption of licit and illicit PSs during pregnancy in Argentina. In contrast to most nearby countries, cocaine was the most detected illicit PS in this cohort of Argentine delivering women. This finding highlights the importance of regular monitoring of local trends in PS use during pregnancy.


Asunto(s)
Cabello , Psicotrópicos , Detección de Abuso de Sustancias , Humanos , Femenino , Embarazo , Argentina/epidemiología , Proyectos Piloto , Adulto , Cabello/química , Psicotrópicos/análisis , Estudios Transversales , Prevalencia , Detección de Abuso de Sustancias/métodos , Adulto Joven , Consumo de Bebidas Alcohólicas/epidemiología , Complicaciones del Embarazo/epidemiología , Trastornos Relacionados con Sustancias/epidemiología
17.
Clin Chem Lab Med ; 62(9): 1845-1852, 2024 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-38578968

RESUMEN

OBJECTIVES: Smartphones have become everyday objects on which the accumulation of fingerprints is significant. In addition, a large proportion of the population regularly uses a smartphone, especially younger people. The objective of this study was to evaluate smartphones as a new matrix for toxico-epidemiology. METHODS: This study was conducted during two separate events (techno and trance) at an electronic music nightclub in Grenoble, France. Data on reported drug use and whether drugs were snorted directly from the surface of the smartphone were collected using an anonymous questionnaire completed voluntarily by drug users. Then, a dry swab was rubbed for 20 s on all sides of the smartphone. The extract was analyzed by liquid chromatography coupled to tandem mass spectrometry on a Xevo TQ-XS system (Waters). RESULTS: In total, 122 swabs from 122 drug users were collected. The three main drugs identified were MDMA (n=83), cocaine (n=59), and THC (n=51). Based on declarative data, sensitivity ranged from 73 to 97.2 % and specificity from 71.8 to 88.1 % for MDMA, cocaine, and THC. Other substances were identified such as cocaine adulterants, ketamine, amphetamine, LSD, methamphetamine, CBD, DMT, heroin, mescaline, and several NPS. Numerous medications were also identified, such as antidepressants, anxiolytics, hypnotics, and painkillers. Different use patterns were identified between the two events. CONCLUSIONS: This proof-of-concept study on 122 subjects shows that smartphone swab analysis could provide a useful and complementary tool for drug testing, especially for harm-reduction programs and toxico-epidemiolgy studies, with acceptable test performance, despite declarative data.


Asunto(s)
Teléfono Inteligente , Humanos , Detección de Abuso de Sustancias/métodos , Detección de Abuso de Sustancias/instrumentación , Adulto , Masculino , Femenino , Espectrometría de Masas en Tándem/métodos , Adulto Joven , Cromatografía Liquida/métodos , Persona de Mediana Edad , Prueba de Estudio Conceptual , Drogas Ilícitas/análisis
18.
Anal Bioanal Chem ; 416(6): 1427-1441, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38270632

RESUMEN

Accurate quantitative analyses require standardized methods to control and improve the analytical process in the laboratory. The availability of urine reference materials (RMs) may offer a feasible option to improve the accuracy of urine analysis and to control matrix effects. This paper presents the complete process of the development of matrix RMs in urine, including sample preparation, homogeneity, and stability studies, as well as uncertainty assessment. A freeze-drying process was developed, and freeze-dried human and pig urine samples were prepared and verified to have comparable homogeneity to liquid samples and higher stability than liquid human, pig, and artificial urine samples at 4℃ or room temperature and under extreme conditions. A total of 21 authentic urine samples from August 2022 were measured with freeze-dried RMs and spiked urine samples, and the reliability of the quantification of the RMs was compared. The freeze-dried human urine matrix RM appeared to be an excellent tool for daily quality control, as it showed high stability and gave the most consistent results with spiked samples.


Asunto(s)
Manejo de Especímenes , Urinálisis , Humanos , Animales , Porcinos , Reproducibilidad de los Resultados , Estándares de Referencia , Detección de Abuso de Sustancias
19.
Anal Bioanal Chem ; 416(13): 3223-3237, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38573345

RESUMEN

Over the past few decades, anabolic androgenic steroids (AASs) have been abused in and out of competition for their performance-enhancing and muscle-building properties. Traditionally, AASs were commonly detected using gas chromatography-mass spectrometry in the initial testing procedure for doping control purposes. Gas chromatography-Orbitrap high-resolution mass spectrometry (GC-Orbitrap-HRMS) is a new technology that has many advantages in comparison with GC-MS (e.g., a maximum resolving power of 240,000 (FWHM at m/z 200), excellent sub-ppm mass accuracy, and retrospective data analysis after data acquisition). Anti-doping practitioners are encouraged to take full advantage of the updated techniques of chromatography-mass spectrometry to develop sensitive, specific, and rapid screening methods for AASs. A new method for screening a wide range of AASs in human urine using GC-Orbitrap-HRMS was developed and validated. The method can qualitatively determine 70 anabolic androgenic steroids according to the minimum required performance limit of the World Anti-Doping Agency. Moreover, the validated method was successfully applied to detect six metabolites in urine after the oral administration of metandienone, and their excretion curves in vivo were studied. Metandienone M6 (17ß-hydroxymethyl-17α-methyl-18-nor-androst-1,4,13-trien-3-one) has been identified as a long-term urinary metabolite which can be detected up to 7 weeks, thus providing a longer detection window compared with previous studies. This study provides a rationale for GC-Orbitrap-HRMS in drug metabolism and non-targeted screening.


Asunto(s)
Anabolizantes , Esteroides Anabólicos Androgénicos , Doping en los Deportes , Cromatografía de Gases y Espectrometría de Masas , Detección de Abuso de Sustancias , Humanos , Masculino , Anabolizantes/orina , Esteroides Anabólicos Androgénicos/orina , Andrógenos/orina , Cromatografía de Gases y Espectrometría de Masas/métodos , Límite de Detección , Detección de Abuso de Sustancias/métodos
20.
Anal Bioanal Chem ; 416(13): 3239-3250, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38573343

RESUMEN

Cocaine and antidepressants rank high globally in substance consumption, emphasizing their impact on public health. The determination of these compounds and related substances in biological samples is crucial for forensic toxicology. This study focused on developing an innovative analytical method for the determination of cocaine, antidepressants, and their related metabolites in postmortem blood samples, using unmodified commercial Fe3O4 nanoparticles as a sorbent for dispersive magnetic solid-phase extraction (m-d-SPE), coupled with liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) analysis. An aliquot of 100 µL of whole blood and 5 µL of the internal standard pool were added to 30 mg of nanoparticles. The nanoparticles were separated from the sample using a neodymium magnet inserted into a 3D-printed microtube rack. The liquid was then discarded, followed by desorption with 300 µL of 1/1/1 acetonitrile/methanol/ethyl acetate. The sample was vortexed and separated, and 1.5 µL of the organic supernatant was injected into the LC-MS/MS. The method was acceptably validated and successfully applied to 263 postmortem blood samples. All samples evaluated in this study were positive for at least one substance. The most frequent analyte was benzoylecgonine, followed by cocaine and cocaethylene. The most common antidepressants encountered in the analyzed samples were citalopram and fluoxetine, followed by fluoxetine's metabolite norfluoxetine. This study describes the first report of this sorbent in postmortem blood analysis, demonstrating satisfactory results for linearity, precision, accuracy, and selectivity for all compounds. The method's applicability was confirmed, establishing it as an efficient and sustainable alternative to traditional techniques for forensic casework.


Asunto(s)
Antidepresivos , Cocaína , Toxicología Forense , Nanopartículas de Magnetita , Extracción en Fase Sólida , Espectrometría de Masas en Tándem , Humanos , Cocaína/sangre , Cocaína/análogos & derivados , Antidepresivos/sangre , Espectrometría de Masas en Tándem/métodos , Toxicología Forense/métodos , Extracción en Fase Sólida/métodos , Nanopartículas de Magnetita/química , Cromatografía Liquida/métodos , Límite de Detección , Detección de Abuso de Sustancias/métodos , Masculino , Femenino , Adulto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA