Your browser doesn't support javascript.
loading
Recurrence of aortic insufficiency after aortic root remodeling with valve preservation.
Luciani, G B; Casali, G; Tomezzoli, A; Mazzucco, A.
Afiliación
  • Luciani GB; Division of Cardiac Surgery and Pathology, University of Verona, Italy. Luciani@netbusiness.it
Ann Thorac Surg ; 67(6): 1849-52; discussion 1853-6, 1999 Jun.
Article en En | MEDLINE | ID: mdl-10391324
ABSTRACT

BACKGROUND:

Aortic root remodeling (ARR) has recently been proposed for patients with aortic aneurysms and valve insufficiency (AI). To define factors associated with a favorable functional outcome, a review of the mid-term results with ARR was undertaken.

METHODS:

Between March 1994 and October 1997, 17 consecutive patients (11 men, 6 women), aged 57 +/- 11 years (range 35-71), had elective ARR for aortic aneurysm with or without annuloaortic ectasia (13), sinus of Valsalva aneurysm (3), or chronic aortic dissection (1). Moderate or severe AI was present in 11 patients (65%). Preoperative aortic root diameter was 58 +/- 5 mm (range 51-70). ARR involved replacement of all three aortic sinuses and coronary button reimplantation, using grafts with a mean diameter of 28 +/- 2 mm (range 24-30).

RESULTS:

There was one early death (6%) due to multiple organ failure. Survivors were followed for 16 +/- 12 months (range 1-44). Actuarial 3-year survival was 94% +/- 6%. Discharge echocardiogram showed a decrease in AI in all patients AI was absent in 11 (69%) and mild in 5 (31%). Recurrence of moderate or severe AI after a mean of 16 +/- 9 months (range 9-28) was noted in 6 patients (37%), 3 of whom had no AI at discharge. Five of 6 patients required aortic valve replacement. Comparison of demographic and operative variables showed that severe preoperative AI (67% vs 20%, p = 0.06), annuloaortic ectasia (100% vs 20%, p = 0.002), and cystic medial necrosis (100% vs 20%, p = 0.002) were significantly more prevalent in patients developing severe AI at follow-up. The 10 patients (63%) with absent AI showed durable competence of the valve and relief from symptoms at follow-up.

CONCLUSIONS:

Despite early restoration of valve competence, AI may recur and progress after ARR at medium-term follow-up in a proportion of patients. The severity of preoperative AI and the nature of aortic root disease may negatively influence the durability of repair. Continued observation of results with ARR appears mandatory to identify the appropriate surgical candidates.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aorta / Aneurisma de la Aorta / Insuficiencia de la Válvula Aórtica / Complicaciones Posoperatorias Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ann Thorac Surg Año: 1999 Tipo del documento: Article País de afiliación: Italia
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Aorta / Aneurisma de la Aorta / Insuficiencia de la Válvula Aórtica / Complicaciones Posoperatorias Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Ann Thorac Surg Año: 1999 Tipo del documento: Article País de afiliación: Italia