Your browser doesn't support javascript.
loading
Static and dynamic biomechanical properties of the regenerating rabbit Achilles tendon.
Nagasawa, Koji; Noguchi, Masahiko; Ikoma, Kazuya; Kubo, Toshikazu.
Afiliación
  • Nagasawa K; Department of Orthopaedics, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto 602-8566, Japan.
Clin Biomech (Bristol, Avon) ; 23(6): 832-8, 2008 Jul.
Article en En | MEDLINE | ID: mdl-18342416
ABSTRACT

BACKGROUND:

Since tendons show viscoelastic behavior, dynamic viscoelastic properties should be assessed in addition to static biomechanical properties. We evaluated differences between static and dynamic biomechanical properties of the regenerating rabbit Achilles tendon following tenotomy.

METHODS:

At 3, 6, or 12 weeks after right Achilles tenotomy, the right (regenerating) and left (control) tendons were collected with the calcaneus from 49 rabbits. A unidirectional failure test and a dynamic viscoelastic test were conducted.

FINDINGS:

Tensile strength and Young's modulus (static biomechanical properties) in the regenerating group at Week 6 were significantly greater than at Week 3, while at Week 12, these were significantly greater than at Week 6. However, even at Week 12, both parameters were less than in the control group. The value of tan delta represents dynamic viscoelasticity, a smaller tan delta indicates greater elasticity. tan delta for the regenerating group was significantly greater than for the control group at Week 3, but regenerating and control groups did not significantly differ at Week 6. No marked change was seen from Weeks 6 to 12 in the regenerating group, and no significant difference in tan delta was evident between the regenerating and control groups at Week 12.

INTERPRETATION:

Dynamic biomechanical properties of regenerating rabbit Achilles tendons may improve more rapidly than static biomechanical properties. Ability to tolerate dynamic movement in the healing Achilles tendon may improve more rapidly than ability to withstand static stresses.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Regeneración / Tendón Calcáneo / Recuperación de la Función Límite: Animals Idioma: En Revista: Clin Biomech (Bristol, Avon) Asunto de la revista: ENGENHARIA BIOMEDICA / FISIOLOGIA Año: 2008 Tipo del documento: Article País de afiliación: Japón

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Regeneración / Tendón Calcáneo / Recuperación de la Función Límite: Animals Idioma: En Revista: Clin Biomech (Bristol, Avon) Asunto de la revista: ENGENHARIA BIOMEDICA / FISIOLOGIA Año: 2008 Tipo del documento: Article País de afiliación: Japón