Your browser doesn't support javascript.
loading
Significance of independent radon entry rate and air exchange rate assessment for the purpose of radon mitigation effectiveness proper evaluation: case studies.
Fronka, A; Jílek, K; Moucka, L; Brabec, M.
Afiliación
  • Fronka A; National Radiation Protection Institute, Prague, Czech Republic. ales.fronka@suro.cz
Radiat Prot Dosimetry ; 145(2-3): 133-7, 2011 May.
Article en En | MEDLINE | ID: mdl-21460366
ABSTRACT
Two new single-family houses identified as insufficient with regard to existing radon barrier efficiency, have been selected for further examination. A complex set of radon diagnosis procedures has been applied in order to localise and quantify radon entry pathways into the indoor environment. Independent assessment of radon entry rate and air exchange rate has been carried out using the continuous indoor radon measurement and a specific tracer gas application. Simultaneous assessment of these key determining factors has turned out to be absolutely crucial in the context of major cause identification of elevated indoor radon concentration.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Radón / Contaminación del Aire Interior / Contaminación Radiactiva del Aire / Modelos Teóricos Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Radiat Prot Dosimetry Año: 2011 Tipo del documento: Article País de afiliación: República Checa

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Radón / Contaminación del Aire Interior / Contaminación Radiactiva del Aire / Modelos Teóricos Tipo de estudio: Prognostic_studies Límite: Humans Idioma: En Revista: Radiat Prot Dosimetry Año: 2011 Tipo del documento: Article País de afiliación: República Checa