Your browser doesn't support javascript.
loading
[Development of a digital chest phantom for studies on energy subtraction techniques].
Hayashi, Norio; Taniguchi, Anna; Noto, Kimiya; Shimosegawa, Masayuki; Ogura, Toshihiro; Doi, Kunio.
Afiliación
  • Hayashi N; School of Radiological Technology, Gunma Prefectural College of Health Sciences.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 70(3): 191-8, 2014 Mar.
Article en Ja | MEDLINE | ID: mdl-24647055
ABSTRACT
Digital chest phantoms continue to play a significant role in optimizing imaging parameters for chest X-ray examinations. The purpose of this study was to develop a digital chest phantom for studies on energy subtraction techniques under ideal conditions without image noise. Computed tomography (CT) images from the LIDC (Lung Image Database Consortium) were employed to develop a digital chest phantom. The method consisted of the following four

steps:

1) segmentation of the lung and bone regions on CT images; 2) creation of simulated nodules; 3) transformation to attenuation coefficient maps from the segmented images; and 4) projection from attenuation coefficient maps. To evaluate the usefulness of digital chest phantoms, we determined the contrast of the simulated nodules in projection images of the digital chest phantom using high and low X-ray energies, soft tissue images obtained by energy subtraction, and "gold standard" images of the soft tissues. Using our method, the lung and bone regions were segmented on the original CT images. The contrast of simulated nodules in soft tissue images obtained by energy subtraction closely matched that obtained using the gold standard images. We thus conclude that it is possible to carry out simulation studies based on energy subtraction techniques using the created digital chest phantoms. Our method is potentially useful for performing simulation studies for optimizing the imaging parameters in chest X-ray examinations.
Asunto(s)
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Radiografía Torácica / Intensificación de Imagen Radiográfica / Tomografía Computarizada por Rayos X / Técnica de Sustracción / Fantasmas de Imagen / Neoplasias Pulmonares Límite: Humans Idioma: Ja Revista: Nihon Hoshasen Gijutsu Gakkai Zasshi Año: 2014 Tipo del documento: Article
Buscar en Google
Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Radiografía Torácica / Intensificación de Imagen Radiográfica / Tomografía Computarizada por Rayos X / Técnica de Sustracción / Fantasmas de Imagen / Neoplasias Pulmonares Límite: Humans Idioma: Ja Revista: Nihon Hoshasen Gijutsu Gakkai Zasshi Año: 2014 Tipo del documento: Article