Your browser doesn't support javascript.
loading
Effect of pulsatile and nonpulsatile flow on cerebral perfusion in patients with left ventricular assist devices.
Cornwell, William K; Tarumi, Takashi; Aengevaeren, Vincent L; Ayers, Colby; Divanji, Punag; Fu, Qi; Palmer, Dean; Drazner, Mark H; Meyer, Dan M; Bethea, Brian T; Hastings, Jeffrey L; Fujimoto, Naoki; Shibata, Shigeki; Zhang, Rong; Markham, David W; Levine, Benjamin D.
Afiliación
  • Cornwell WK; Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital, Dallas, Texas; Department of Internal Medicine, Division of Cardiology, University of Texas Southwestern Medical Center, Dallas, Texas.
  • Tarumi T; Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital, Dallas, Texas.
  • Aengevaeren VL; Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital, Dallas, Texas; Department of Geriatric Medicine, Radboud University, Nijmegen Medical Center, Nijmegen, The Netherlands.
  • Ayers C; Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital, Dallas, Texas.
  • Divanji P; Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital, Dallas, Texas.
  • Fu Q; Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital, Dallas, Texas.
  • Palmer D; Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital, Dallas, Texas.
  • Drazner MH; Department of Internal Medicine, Division of Cardiology, University of Texas Southwestern Medical Center, Dallas, Texas.
  • Meyer DM; Department of Internal Medicine, Division of Cardiology, University of Texas Southwestern Medical Center, Dallas, Texas.
  • Bethea BT; Department of Internal Medicine, Division of Cardiology, University of Texas Southwestern Medical Center, Dallas, Texas.
  • Hastings JL; Department of Internal Medicine, Division of Cardiology, University of Texas Southwestern Medical Center, Dallas, Texas.
  • Fujimoto N; Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital, Dallas, Texas.
  • Shibata S; Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital, Dallas, Texas.
  • Zhang R; Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital, Dallas, Texas; Department of Internal Medicine, Division of Cardiology, University of Texas Southwestern Medical Center, Dallas, Texas.
  • Markham DW; Department of Medicine, Division of Cardiology, Emory University, Atlanta, Georgia.
  • Levine BD; Institute for Exercise and Environmental Medicine, Texas Health Presbyterian Hospital, Dallas, Texas; Department of Internal Medicine, Division of Cardiology, University of Texas Southwestern Medical Center, Dallas, Texas. Electronic address: benjaminlevine@texashealth.org.
J Heart Lung Transplant ; 33(12): 1295-303, 2014 Dec.
Article en En | MEDLINE | ID: mdl-25307621
ABSTRACT

BACKGROUND:

Insertion of a left ventricular assist device (LVAD) is an accepted therapy for advanced heart failure patients. However, the effects on end-organ perfusion, including cerebral autoregulation, are unclear in the presence of reduced pulsatility. Therefore, the objective of this study was to determine whether cerebral autoregulation is impaired in patients with continuous-flow (CF) LVADs.

METHODS:

Dynamic cerebral autoregulation was assessed in both time-domain (autoregulatory index) and frequency-domain (transfer function analysis) analyses in 9 CF-LVAD subjects, 5 pulsatile LVAD subjects and 10 healthy controls, by evaluating mean arterial pressure (MAP) and cerebral blood flow velocity (CBFV) during a sit-stand maneuver at 0.05 Hz (10-second sit, 10-second stand). The autoregulatory index was calculated as the percent change in mean CBFV per mm Hg change in MAP.

RESULTS:

The magnitude of oscillation in MAP and CBFV was greater in subjects with pulsatile LVADs than either CF-LVADs or healthy controls (p = 0.065 for MAP, p = 0.004 for CBFV). The autoregulatory index and transfer function gain were similar among groups, indicating that dynamic cerebral autoregulation is preserved among patients with CF-LVADs.

CONCLUSIONS:

Cerebral blood flow in patients with CF-LVADs is comparable to that of healthy controls across a range of blood pressures. Patients with pulsatile devices have greater oscillations in MAP and CBFV. However, dynamic cerebral autoregulation is preserved among subjects with either type of device. Thus, the reduction in pulsatility afforded by CF-LVADs does not impair normal autoregulatory processes.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Flujo Pulsátil / Circulación Cerebrovascular / Corazón Auxiliar / Disfunción Ventricular Izquierda / Insuficiencia Cardíaca Tipo de estudio: Observational_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Heart Lung Transplant Asunto de la revista: CARDIOLOGIA / TRANSPLANTE Año: 2014 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Flujo Pulsátil / Circulación Cerebrovascular / Corazón Auxiliar / Disfunción Ventricular Izquierda / Insuficiencia Cardíaca Tipo de estudio: Observational_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Heart Lung Transplant Asunto de la revista: CARDIOLOGIA / TRANSPLANTE Año: 2014 Tipo del documento: Article