Your browser doesn't support javascript.
loading
Is mortality a useful parameter for public reporting in pacemaker implantation? Results of an obligatory external quality control programme.
Nowak, Bernd; Misselwitz, Björn; Przibille, Oliver; Mehta, Rajendra H.
Afiliación
  • Nowak B; CCB, Cardioangiologisches Centrum Bethanien, Im Pruefling 23, D-60389 Frankfurt a.M., Germany.
  • Misselwitz B; Institute of Quality Assurance Hessen, Eschborn, Germany.
  • Przibille O; CCB, Cardioangiologisches Centrum Bethanien, Im Pruefling 23, D-60389 Frankfurt a.M., Germany.
  • Mehta RH; Duke Clinical Research Institute and Duke University Medical Center, Durham, NC, USA.
Europace ; 19(4): 568-572, 2017 Apr 01.
Article en En | MEDLINE | ID: mdl-28431064
AIMS: To evaluate if public reporting of pacemaker implantation-associated mortality is meaningful in a large contemporary patient cohort. METHODS AND RESULTS: The database of the obligatory external quality control programme in the Federal State of Hessen, Germany, of patients undergoing permanent pacemaker (PPM) implantation was evaluated retrospectively. We compared the baseline features of patients who died compared with those who did not during hospitalization after PPM. Of 5079 patients who underwent PPM implantation in 2009, 74 (1.5%) died during the hospital stay. Cause of death was available in 70/74 patients (94.6%) who died. Deceased patients were older (79.6 ± 8.7 vs. 76.3 ± 9.9 years, P = 0.006), had worse American Society of Anesthesiologists (ASA) physical status (P < 0.001), lower ejection fraction (P < 0.001), a greater prevalence of high-degree atrioventricular-block (44.3 vs. 35.0%, P = 0.001), and were more likely to receive single-chamber devices (41.4 vs. 25.0%, P < 0.002). Perioperative complications were similar in both cohorts. Death was not attributable directly to PPM procedure in any patients but was related to (i) non-device-related infections (28.6%), (ii) heart failure (25.7%), (iii) extracardiac diseases (21.4%), (iv) multiorgan failure (8.6%), (v) previous resuscitation with hypoxic brain damage (8.6%), and (vi) arrhythmogenic death (7.1%). CONCLUSION: Mortality associated with PPM implantation in vast majority of cases was not related to the procedure, but to comorbidities and other existing diseases at the time of PPM implantation. Thus, PPM implantation in-hospital mortality should not be chosen for public reporting comparing hospital quality, even after adjusting for baseline risk.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Arritmias Cardíacas / Gestión de Riesgos / Estimulación Cardíaca Artificial / Evaluación de Resultado en la Atención de Salud / Mortalidad Hospitalaria / Muerte Súbita Cardíaca / Hospitalización Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: Europace Asunto de la revista: CARDIOLOGIA / FISIOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Arritmias Cardíacas / Gestión de Riesgos / Estimulación Cardíaca Artificial / Evaluación de Resultado en la Atención de Salud / Mortalidad Hospitalaria / Muerte Súbita Cardíaca / Hospitalización Tipo de estudio: Etiology_studies / Incidence_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Aged / Female / Humans / Male Idioma: En Revista: Europace Asunto de la revista: CARDIOLOGIA / FISIOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Alemania