The Validity and Reliability of Knee Proprioception Measurement Performed With Inclinometer in Different Positions.
Suner-Keklik, Sinem; Cobanoglu-Seven, Gamze; Kafa, Nihan; Ugurlu, Mustafa; Guzel, Nevin Atalay.
Afiliación
  • Suner-Keklik S; 1 Gazi University , Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Ankara, Turkey.
  • Cobanoglu-Seven G; 1 Gazi University , Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Ankara, Turkey.
  • Kafa N; 1 Gazi University , Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Ankara, Turkey.
  • Ugurlu M; 2 Ankara Atatürk Training and Research Hospital , Psychiatry Department, Ankara, Turkey.
  • Guzel NA; 1 Gazi University , Faculty of Health Sciences, Department of Physiotherapy and Rehabilitation, Ankara, Turkey.
J Sport Rehabil ; 26(6)2017 11 01.
Article en En | MEDLINE | ID: mdl-28605314
ABSTRACT
CONTEXT Proprioception is the basic element of the spontaneous control of movement, balance and joint stability. Therefore, it is necessary for the execution of walking and daily and sport activities. Loss of proprioception of the knee, which may cause a new injury, is important to evaluate the position sense of the joint during the rehabilitation period. However, the evaluation methods that are used are very expensive, complicated and non-portable, or the measuring method is difficult to implement.

OBJECTIVE:

We demonstrated the validity and reliability of knee proprioception measurements performed in the open kinetic chain position and closed kinetic chain position with a dual inclinometer.

DESIGN:

We assessed the validity and intra-tester reliability of a digital inclinometer for measuring the knee joint position sense in different positions.

SETTING:

Clinical laboratory.

PARTICIPANTS:

We enrolled 22 participants (age = 21.8 ± 0.95 years, height = 172 ± 9.1 cm, weight = 64.9 ± 14 kg) into the study. INTERVENTION The same investigator used an inclinometer to take knee proprioception measurements in open and closed kinetic chain positions. MAIN OUTCOME

MEASURES:

The relative angular error was calculated by taking the arithmetic average of the difference between the target angle and reproduced angle and was the main outcome measure.

RESULTS:

We found that the dynamometer-inclinometer had a moderate ICC value (ICC = 0.594, SEM = 1.60, p = 0.005), whereas inclinometer t1 vs inclinometer t2 (ICC = 0.778, SEM = 0.62, p < 0.001) and closed kinetic chain position t1 and closed kinetic chain position t2 (ICC = 0.888, SEM = 0.63, p < 0.001) had high ICC values.

CONCLUSION:

Knee proprioception measurements performed with a dual inclinometer were reliable in the closed kinetic chain position in healthy, sedentary individuals and were valid and reliable in the open kinetic chain position.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Propiocepción / Artrometría Articular / Articulación de la Rodilla Límite: Adult / Humans Idioma: En Revista: J Sport Rehabil Asunto de la revista: MEDICINA ESPORTIVA / REABILITACAO Año: 2017 Tipo del documento: Article País de afiliación: Turquía

Texto completo: 1 Colección: 01-internacional Banco de datos: MEDLINE Asunto principal: Propiocepción / Artrometría Articular / Articulación de la Rodilla Límite: Adult / Humans Idioma: En Revista: J Sport Rehabil Asunto de la revista: MEDICINA ESPORTIVA / REABILITACAO Año: 2017 Tipo del documento: Article País de afiliación: Turquía